{"asOf":"2026-07-27T21:13:58.226Z","block":"600-699 MC CLELLAN ST","blockUrl":"https://philadelphia.blockreport.homes/block/600-699-mc-clellan-st","address":"603 MCCLELLAN ST","parcelNumber":"011395902","source":"https://property.phila.gov/?p=011395902","ownerType":"absentee","kind":"house","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"SI","buildingCodeNew":"25","buildingClass":"VACANT LAND INDUST < ACRE","buildingClassNew":"ROW MODERN","useLabel":"House","owner":"CRETELLA RISA","coOwner":null,"marketValue":602900,"landAssessment":120580,"improvementAssessment":482320,"livableArea":1809,"yearBuilt":2021,"lastSale":{"price":630000,"date":"2025-04-08T04:00:00Z"},"openViolations":0,"violations":[],"violationCases":[],"investigations":[],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.926018334837515,"lng":-75.15607110194004,"geom":{"type":"Polygon","coordinates":[[[-75.156054954,39.925962719],[-75.15611031,39.925969998],[-75.156087249,39.926073951],[-75.156031894,39.926066672],[-75.156054954,39.925962719]]]},"liDistrict":"SOUTH","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19148","beds":3,"baths":2,"stories":3,"lotArea":280,"zoning":"RSA5","grade":null,"basement":"A","heater":"A","centralAir":true,"extCond":"1","intCond":"1","garage":2,"homestead":false,"mail":"4057 RIVER OAKS RD, CLOVER SC, 29710","mailOut":true,"appeals":[],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":true,"assessmentExemption":true,"exemptionBasisVerified":false,"valueSeries":[{"y":2022,"v":70000,"taxable":70000,"land":70000,"improvement":0,"taxableLand":70000,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":533500,"taxable":106700,"land":106700,"improvement":426800,"taxableLand":106700,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":426800},{"y":2024,"v":533500,"taxable":106700,"land":106700,"improvement":426800,"taxableLand":106700,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":426800},{"y":2025,"v":594700,"taxable":118940,"land":118940,"improvement":475760,"taxableLand":118940,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":475760},{"y":2026,"v":594700,"taxable":118940,"land":118940,"improvement":475760,"taxableLand":118940,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":475760},{"y":2027,"v":602900,"taxable":120580,"land":120580,"improvement":482320,"taxableLand":120580,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":482320}],"taxNow":1665,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"953777","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2022-06-06","scope":"ERECTION OF A 3 STORY SFD HOME LABELED AS UNIT #25 TO INCLUDE ROOF ACCESS STRUCTURE TO ROOF DECK 11-25-2020 Permit Amended to change address 1-24-2021 Permit Amended - the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street"},{"number":"953781","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-06-01","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (12 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION AMENDMENT AS OF 11/24/2020: FOR THE ERECTION OF A THREE (3) STORY WOOD FRAME TOWNHOUSE WITH ROOF DECK AND ROOF DECK ACCESS STRUCTURE, FOR USE AS A SINGLE-FAMILY DWELLING."},{"number":"953770","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2020-12-02","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. Amended 11-25-20 to change address FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.PLANS"},{"number":"955220","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-03-11","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. Amendment 11-25-2020 Change of Address 1-24-2021 Permit Amended - the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street"},{"number":"955229","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2022-06-13","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. 11-25-2020 Amend Permit to Change Address 1-30-21 Amend Permit special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street"},{"number":"955228","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-09-21","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. 11-25-2020 Amend Permit to Change Address"},{"number":"955221","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-02-23","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. Amend Permit 11-25-2020 to Change Address Amend Permit 1-2-2021 CHANGE OF SPECIAL INSPECTOR TO TREVOR HENRY P.E., HENRY BUILDING SERVICES LLC"},{"number":"955222","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-05-06","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. 11-25-2020 Amend Permit to Change Address 1-24-2021 Amend Permit - special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street"},{"number":"955223","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-05-06","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. 11-25-2020 Amend Permit to Change Address 1-24-2021 Amend Permit - special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street"},{"number":"955224","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-06-07","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. 11-25-2020 Amend Permit to Change Address 1-25-2021 Amend Permit - The special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street"},{"number":"955227","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2022-04-06","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. Amend 1-27-2021 - the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street 11-25-2020 Amend Permit to Change Address"},{"number":"955225","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-07-29","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. 11-25-2020 Amend Permit to Change Address 1-25-2021 Amend Permit - The special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street"},{"number":"955226","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-10-05","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE (NTE 38' HIGH); ROOF DECK ACCESSED BY A PILOTHOUSE FOR A MULTI-FAMILY HOUSEHOLD LIVING (11 DWELLING UNITS) FROM CELLAR THRU THIRD FLOORS WITH FOURTY-TWO (42) ACCESSORY PARKING SPACES INCLUDING WITH TWO (2)ACCESSIBLE SPACES INCLUDING WITH TWO (2) VAN ACCESSIBLE SPACE,ELEVEN (11) COMPACT SPACES,FIVE (5) ELECTRIC VAN SPACES AND WITH NINE (9) BICYCLE SPACES AT GROUND FLOOR IN AN ACCESSIBLE ROUTE.SIZE AND LOCATION AS SHOWN IN THE APPLICATION 953770. 11-25-2020 Amend Permit to Change Address 1-26-2021 Amend Permit - the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street,"},{"number":"953743","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2020-12-02","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS Amended 11-25-20 to change address"},{"number":"955570","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-01-25","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS Amend 11-25-20 Change of Address"},{"number":"955571","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-03-11","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS Amend Permit 11-25-2020 Change of Address amended on 1/22/21 to update the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached."},{"number":"955572","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-03-02","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend permit to change address 2-23-2021 Update the special inspector associated with this permit to be Trevor Henry P.E."},{"number":"955573","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-05-06","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amended Permit to Change Address permit amended on 1/15/21 to include following: Please update the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached."},{"number":"955574","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-06-07","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend Permit to Change Address permit amended on 1/26/21 to update the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached."},{"number":"955575","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-06-07","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend Permit to Change Address 1/18/21, Permit amended to add the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached."},{"number":"955576","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-07-29","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend Permit to Correct Address 1/18/21, permit amended to update the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached."},{"number":"955577","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-08-11","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend Permit to Change Address 1-26-2021 Amend Permit - the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street,"},{"number":"955578","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-10-01","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend Permit to Change Address permit amended on 1/22/21 to update the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached."},{"number":"955579","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2022-05-26","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend Permit to Change Address. permit amended on 1/25/21 to update the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached"},{"number":"955580","date":"2019-06-13","work":"New Construction","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2022-03-30","scope":"FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH CELLAR, ROOF DECK WITH PILOT HOUSE AND WITH INTERIOR OFF STREET PARKING SPACE (DETAILS INCLUDING SIZE AND LOCATION AS SHOWN ON THE PLAN) FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPERATE PERMITS REQUIRE FOR ALL TRADE WORKS.SEE AP# 953743 FOR PLANS 11-25-2020 Amend Permit to Change Address permit amended on 1/25/21 to update the special inspector associated with this permit to be Trevor Henry P.E. for 601 McClellan Street, Units 1-25. Signed and sealed Duties & Responsibilities Agreement and Statement of Special Inspections attached"},{"number":"PP-2020-004036","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-05-06","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2020-004022","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-11-25","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2020-004032","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-02-08","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2020-003996","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-11-25","scope":"For Exterior Plumbing to include CURB TRAP, FRESH AIR INLET, HOUSE DRAIN, 1\" WATER SERVICE, [3]WATER CLOSETS, [3]LAVATORIES, [3]SHOWERS/TUBS, [1]KITCHEN SINK, [1]WATER HEATER, and [1]LAUNDRY SINK as per 2018 Philadelphia Plumbing Code. BP #955570"},{"number":"PP-2020-004033","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-03-01","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2020-004027","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-03-03","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2020-004026","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-03-03","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2020-004025","date":"2020-07-10","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-12-22","scope":"For Exterior Plumbing to include CURB TRAP, FRESH AIR INLET, HOUSE DRAIN, 1\" WATER SERVICE, [3]WATER CLOSETS, [3]LAVATORIES, [3]SHOWERS/TUBS, [1]KITCHEN SINK, [1]WATER HEATER, and [1]LAUNDRY SINK as per 2018 Philadelphia Plumbing Code. BP #955570"},{"number":"FP-2020-001259","date":"2020-08-14","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-03-29","scope":"FOR THE INSTALLATION OF 1-INCH COMBINED FIRE/WATER SERVICE AND FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13D."},{"number":"FP-2020-001265","date":"2020-08-21","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-08-10","scope":"INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D THROUGHOUT NEW THREE STORY BUILDING (UNIT 18) TO INCLUDE ONE INCH COMBINED LINE AS PER APPROVED PLANS."},{"number":"FP-2020-001264","date":"2020-08-27","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-03-29","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D, WITH A ONE-INCH FIRE SERVICE LINE, FOR A SINGLE-FAMILY DWELLING, AS PER APPROVED PLANS."},{"number":"FP-2020-001266","date":"2020-08-27","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-10-01","scope":"FOR THE INSTALLATION OF 1-INCH COMBINED FIRE/WATER SERVICE AND FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13D."},{"number":"FP-2020-001261","date":"2020-08-27","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-05-26","scope":"FOR THE INSTALLATION OF 1-INCH COMBINED FIRE/WATER SERVICE AND FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13D."},{"number":"FP-2020-001263","date":"2020-08-27","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-10-01","scope":"FOR THE INSTALLATION OF 1-INCH COMBINED FIRE/WATER SERVICE AND FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13D."},{"number":"FP-2020-001260","date":"2020-08-27","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-06-06","scope":"FOR THE INSTALLATION OF 1-INCH COMBINED FIRE/WATER SERVICE AND FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13D."},{"number":"FP-2020-001262","date":"2020-08-27","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-09-21","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D, WITH A ONE-INCH FIRE SERVICE LINE, FOR A SINGLE-FAMILY DWELLING, AS PER APPROVED PLANS."},{"number":"FP-2020-001541","date":"2020-09-15","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-05-06","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2007, STANDARD 13D TO INCLUDE A COMBINED 1-INCH DIAMETER SERVICE LINE."},{"number":"FP-2020-001540","date":"2020-09-15","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-05-06","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2007, STANDARD 13D TO INCLUDE A COMBINED 1-INCH DIAMETER SERVICE LINE."},{"number":"FP-2020-001546","date":"2020-09-17","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-06-07","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM FOR UNIT 14 IN ACCORDANCE WITH NFPA 2007, STANDARD 13D TO INCLUDE A COMBINED 1-INCH DIAMETER SERVICE LINE."},{"number":"FP-2020-001545","date":"2020-09-17","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-06-07","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM FOR UNIT 13 IN ACCORDANCE WITH NFPA 2007, STANDARD 13D TO INCLUDE A COMBINED 1-INCH DIAMETER SERVICE LINE."},{"number":"FP-2020-001548","date":"2020-09-18","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-07-21","scope":"FOR THE INSTALLATION OF AN ONE (1) INCH COMBINED SERVICE LINES FOR FIRE & DOMESTIC SUPPLY LINE. MULTIPURPOSE RESIDENTIAL FIRE SPRINKLER SYSTEM WITH BOOSTER PUMP DESIGNED IN ACCORDANCE WITH NFPA 13D. ALL WORK SHALL BE ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS, AND APPROVED BUILDING PERMIT. ANY DEVIATION WILL REQUIRE A SEPARATE PERMIT."},{"number":"FP-2020-001547","date":"2020-09-18","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-07-21","scope":"FOR THE INSTALLATION OF AN ONE (1) INCH COMBINED SERVICE LINES FOR FIRE & DOMESTIC SUPPLY LINE. MULTIPURPOSE RESIDENTIAL FIRE SPRINKLER SYSTEM WITH BOOSTER PUMP DESIGNED IN ACCORDANCE WITH NFPA 13D. ALL WORK SHALL BE ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS, AND APPROVED BUILDING PERMIT. ANY DEVIATION WILL REQUIRE A SEPARATE PERMIT."},{"number":"FP-2020-001542","date":"2020-09-28","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-06-07","scope":"THE INSTALLATION OF A ONE (1) INCH COMBINED SERVICE LINE FOR A FIRE & DOMESTIC SUPPLY LINE AND FIRE SERVICE LINE WITH REMOTE TOILET CONNECTION PER PLANS. MULTIPURPOSE RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13D. ALL WORK SHALL BE ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS, AND APPROVED BUILDING PERMIT. SEPARATE PERMITS REQUIRED FOR ALL PLUMBING WORK."},{"number":"FP-2020-001188","date":"2020-09-28","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-06-06","scope":"THE INSTALLATION OF A ONE (1) INCH COMBINED SERVICE LINE FOR A FIRE & DOMESTIC SUPPLY LINE AND FIRE SERVICE LINE WITH REMOTE TOILET CONNECTION PER PLANS. MULTIPURPOSE RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13D. ALL WORK SHALL BE ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS, AND APPROVED BUILDING PERMIT. SEPARATE PERMITS REQUIRED FOR ALL PLUMBING WORK."},{"number":"PP-2020-011647","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-04-06","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011548","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-06-06","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011717","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-07-21","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011636","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-09-21","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-009702","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-06-06","scope":"(3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, hot water heater & 1” Combo"},{"number":"PP-2020-011547","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-05-26","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2020-011743","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-05-06","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011701","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-07-30","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011744","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-05-06","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011725","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-07-21","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011532","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-03-30","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011734","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-06-07","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011641","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-10-01","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011715","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-10-01","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011737","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-06-07","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"PP-2020-011712","date":"2020-10-28","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-06-07","scope":"Install (3) Tubs, (3) toilets, (3) Lavs, (1) Washer, (1) Kitchen Sink. Install house drain, house trap, FAI, stack, (1) hot water heater & 1” Combo"},{"number":"EP-2020-010794","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-05-06","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010788","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-29","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010785","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-29","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010796","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-05-06","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010787","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-01","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010789","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-20","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010786","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-01","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010791","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-22","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010790","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-22","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010795","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-05-06","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010793","date":"2020-11-30","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-22","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"MP-2020-006010","date":"2021-01-22","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-01-25","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"MP-2020-006015","date":"2021-02-17","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-03-01","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006013","date":"2021-02-17","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-02-23","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"EP-2020-010828","date":"2021-02-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-06-03","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010832","date":"2021-02-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-06-03","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010829","date":"2021-02-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-06-03","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010834","date":"2021-02-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-07-27","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"EP-2020-010833","date":"2021-02-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-07-09","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"MP-2020-006012","date":"2021-03-09","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-03-11","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS"},{"number":"MP-2020-006011","date":"2021-03-09","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-03-11","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS"},{"number":"PP-2020-010362","date":"2021-03-19","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-03-26","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"MP-2020-006019","date":"2021-03-19","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-05-06","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006020","date":"2021-03-19","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-05-06","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006017","date":"2021-03-19","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-05-06","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006028","date":"2021-04-05","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-06-07","scope":"INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS"},{"number":"EP-2021-003364","date":"2021-04-05","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-07-09","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"MP-2020-006029","date":"2021-04-05","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-06-07","scope":"INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS"},{"number":"MP-2020-006021","date":"2021-04-05","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-06-07","scope":"INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS"},{"number":"EP-2020-010649","date":"2021-04-05","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Cancelled","completedDate":"2021-04-05","scope":"Install 200 AMP electrical service. Wire throughout new single family dwelling: switches, receptacles, lights, phones, TVs, and interconnected smoke/CO detectors as per NEC 2014."},{"number":"MP-2020-006032","date":"2021-04-12","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-07-21","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006030","date":"2021-04-12","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-07-21","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006033","date":"2021-04-20","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-08-11","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006034","date":"2021-04-20","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-10-01","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006027","date":"2021-04-28","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-10-01","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006026","date":"2021-04-28","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-09-21","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006031","date":"2021-04-28","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-04-06","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006023","date":"2021-05-11","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-03-30","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006024","date":"2021-05-11","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-06-06","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006025","date":"2021-05-25","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-05-26","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."},{"number":"MP-2020-006022","date":"2021-05-25","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-06-06","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (INSTALL 75,000 90% EFF FURNACE WITH 3 TON CONDENSER, COIL, DUCTWORK AND 12 SUPPLY REGISTERS)."}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"},{"y":2021,"k":"permit","w":"New Construction"}],"rented":false,"licenses":[],"licenseActivity":[],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"permit-mismatch","level":"watch","title":"Assessment/permit mismatch","summary":"The assessment jumped 662% in 2023, but no matching permit appears in the property timeline.","evidence":["assessment moved from $70,000 to $533,500","no permit shown in 2022-2024"],"caveat":"Not proof of unpermitted work; reassessment, corrected data, or a permit under another parcel can also explain it."}],"legalChecks":[{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"1 permit not marked completed: EP-2020-010649 (Cancelled).","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"abatement","level":"verify","title":"A reduced taxable assessment is not a verified abatement","finding":"OPA’s numeric assessment fields show a reduced taxable assessment; BlockReport has no official program determination for this parcel.","why":"The numeric treatment can reflect an improvement abatement or another exemption. It does not identify the ordinance, approval, start or end date, or continuation requirements after a transfer. Once OPA verifies a specific active abatement, many common programs attach the benefit to the property for the remaining term rather than ending automatically at sale, but some require a new-owner filing and continued qualifying use or tax compliance.","action":"Obtain the OPA exemption/abatement determination and history, then underwrite the buyer’s bill from the verified program terms.","url":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/get-a-property-tax-abatement/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}