{"asOf":"2026-07-26T18:40:00.906Z","block":"1300-1399 MASCHER ST","blockUrl":"https://philadelphia.blockreport.homes/block/1300-1399-mascher-st","address":"1346 MASCHER ST","parcelNumber":"182068000","source":"https://property.phila.gov/?p=182068000","ownerType":"owner-occupied","kind":"house","isHouse":true,"home":true,"commercial":false,"residential":true,"taxExempt":false,"institutional":false,"buildingCode":"P56","buildingCodeNew":"25","buildingClass":"ROW W/GAR 3 STY FRAME","buildingClassNew":"ROW MODERN","useLabel":"House","owner":"BASTIS NICHOLAS","coOwner":"TROYANOSKI ALISON","marketValue":606900,"landAssessment":121380,"improvementAssessment":485520,"livableArea":1914,"yearBuilt":2015,"lastSale":{"price":700000,"date":"2025-01-12T05:00:00Z"},"openViolations":0,"violations":[{"number":"2943855","date":"2013-06-11","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3135981","date":"2014-04-04","code":"PM-405.3/1","title":"INT-PLMBG FIXTURES-RES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3536948","date":"2015-04-28","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3536947","date":"2015-04-28","code":"A-301.1/37","title":"PERMB- UNDERPIN FOUNDATION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3536949","date":"2015-04-28","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3878341","date":"2016-03-19","code":"A-104.1/5","title":"DEBRIS REMOVE - CONSTR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3878340","date":"2016-03-19","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3904713","date":"2016-04-16","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936895","date":"2016-05-16","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936893","date":"2016-05-16","code":"A-301.1/56","title":"PERMP- INST SANITARY PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936894","date":"2016-05-16","code":"A-301.1/57","title":"PERMP- INST DOMEST PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936927","date":"2016-05-16","code":"A-301.1/57","title":"PERMP- INST DOMEST PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936926","date":"2016-05-16","code":"A-301.1/56","title":"PERMP- INST SANITARY PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936928","date":"2016-05-16","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4086778","date":"2016-09-20","code":"E-1201.1/1","title":"NOT CONFORM TO PRC/NEC","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4086781","date":"2016-09-20","code":"E-1201.1/101","title":"SECURE ELECTRICAL EQUIPMENT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3653093","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653084","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653080","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653070","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653033","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653031","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653078","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653077","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3653074","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3776313","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"RESOLVE","resolutionDate":null,"resolution":null},{"number":"4086753","date":"2016-09-20","code":"E-1201.1/1","title":"NOT CONFORM TO PRC/NEC","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4086756","date":"2016-09-20","code":"E-1201.1/101","title":"SECURE ELECTRICAL EQUIPMENT","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"385426","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-06-12","completedDate":"2014-03-19","violations":[{"number":"2943855","date":"2013-06-11","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"425347","type":"HAZARDOUS","priority":"HAZARDOUS","responsibility":"CI","status":"CLOSED","createdDate":"2014-04-07","completedDate":"2014-06-03","violations":[{"number":"3135981","date":"2014-04-04","code":"PM-405.3/1","title":"INT-PLMBG FIXTURES-RES","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"476991","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2015-04-28","completedDate":"2015-04-28","violations":[{"number":"3536948","date":"2015-04-28","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3536947","date":"2015-04-28","code":"A-301.1/37","title":"PERMB- UNDERPIN FOUNDATION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3536949","date":"2015-04-28","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"525176","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DN","status":"CLOSED","createdDate":"2016-03-24","completedDate":"2016-05-24","violations":[{"number":"3878341","date":"2016-03-19","code":"A-104.1/5","title":"DEBRIS REMOVE - CONSTR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3878340","date":"2016-03-19","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"528628","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"CSTF","status":"CLOSED","createdDate":"2016-04-20","completedDate":"2016-05-24","violations":[{"number":"3904713","date":"2016-04-16","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"533303","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2016-05-16","completedDate":"2016-05-24","violations":[{"number":"3936895","date":"2016-05-16","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936893","date":"2016-05-16","code":"A-301.1/56","title":"PERMP- INST SANITARY PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936894","date":"2016-05-16","code":"A-301.1/57","title":"PERMP- INST DOMEST PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"533309","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2016-05-16","completedDate":"2016-05-24","violations":[{"number":"3936927","date":"2016-05-16","code":"A-301.1/57","title":"PERMP- INST DOMEST PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936926","date":"2016-05-16","code":"A-301.1/56","title":"PERMP- INST SANITARY PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3936928","date":"2016-05-16","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"555831","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2016-09-20","completedDate":"2016-10-25","violations":[{"number":"4086778","date":"2016-09-20","code":"E-1201.1/1","title":"NOT CONFORM TO PRC/NEC","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4086781","date":"2016-09-20","code":"E-1201.1/101","title":"SECURE ELECTRICAL EQUIPMENT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"617121","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653093","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617122","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653084","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617115","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653080","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617120","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653070","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617114","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653033","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"613410","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653031","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617116","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653078","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617117","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653077","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617118","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3653074","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"617119","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3776313","date":"2015-07-25","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"RESOLVE","resolutionDate":null,"resolution":null}]},{"number":"697008","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"4086753","date":"2016-09-20","code":"E-1201.1/1","title":"NOT CONFORM TO PRC/NEC","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4086756","date":"2016-09-20","code":"E-1201.1/101","title":"SECURE ELECTRICAL EQUIPMENT","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2013,"n":1,"worst":null},{"y":2014,"n":1,"worst":null},{"y":2015,"n":13,"worst":null},{"y":2016,"n":13,"worst":null}],"investigations":[{"caseNumber":"89567","date":"2006-11-09","type":"BC INSP","status":"CLOSED"},{"caseNumber":"385426","date":"2013-06-11","type":"CI INSP","status":"FAILED"},{"caseNumber":"385426","date":"2013-07-25","type":"CI INSP","status":"FAILED"},{"caseNumber":"385426","date":"2013-09-23","type":"CI INSP","status":"CLOSED"},{"caseNumber":"385426","date":"2013-12-02","type":"PRECOURT","status":"PASSED"},{"caseNumber":"425347","date":"2014-04-04","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"425347","date":"2014-06-02","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"476991","date":"2015-04-28","type":"BP_BLDG","status":"CLOSED"},{"caseNumber":"476991","date":"2015-04-28","type":"BP_BLDG","status":"CLOSED"},{"caseNumber":"525176","date":"2016-03-19","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"528628","date":"2016-04-16","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"528628","date":"2016-05-06","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"525176","date":"2016-05-06","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"533303","date":"2016-05-16","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"533309","date":"2016-05-16","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"533303","date":"2016-05-24","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"533309","date":"2016-05-24","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"555831","date":"2016-09-20","type":"EP_ELEC","status":"FAILED"},{"caseNumber":"555831","date":"2016-10-25","type":"EP_ELEC","status":"PASSED"}],"inspYears":[{"y":2013,"fails":2,"passes":1},{"y":2014,"fails":1,"passes":1},{"y":2016,"fails":5,"passes":5}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.97183849627193,"lng":-75.13742680070196,"geom":{"type":"Polygon","coordinates":[[[-75.137292526,39.971841709],[-75.137302159,39.97179575],[-75.137578219,39.971845896],[-75.137571833,39.971876361],[-75.137292526,39.971841709]]]},"liDistrict":"CENTRAL EAST","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19122","beds":3,"baths":2,"stories":3,"lotArea":1348,"zoning":"RSA5","grade":"B","basement":"A","heater":"A","centralAir":true,"extCond":"3","intCond":"3","garage":1,"homestead":true,"mail":"1346 MASCHER ST, PHILADELPHIA PA, 19122","mailOut":false,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR THE LOT ADJUSTMENT TO CREATE ONE (1) LOT FROM FIFTEEN (15) DEEDED PARCELS (1346-1348 MASCHER STREET, 1350 MASCHER STREET, 1352-1356 MASCHER STREET, 160 W MASTER STREET, 162 W MASTER STREET, 164 W MASTER STREET, 166 W MASTER STREE","status":"CLOSED","outcome":"Granted","date":"2014-12-03","number":"24041","relatedPermit":"568343"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":1,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2018,"v":450000,"taxable":130500,"land":130500,"improvement":319500,"taxableLand":130500,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":319500},{"y":2019,"v":498900,"taxable":144681,"land":144681,"improvement":354219,"taxableLand":144681,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":354219},{"y":2020,"v":495400,"taxable":143666,"land":143666,"improvement":351734,"taxableLand":143666,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":351734},{"y":2021,"v":495400,"taxable":143666,"land":143666,"improvement":351734,"taxableLand":143666,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":351734},{"y":2022,"v":495400,"taxable":143666,"land":143666,"improvement":351734,"taxableLand":143666,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":351734},{"y":2023,"v":610500,"taxable":122100,"land":122100,"improvement":488400,"taxableLand":122100,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":488400},{"y":2024,"v":610500,"taxable":122100,"land":122100,"improvement":488400,"taxableLand":122100,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":488400},{"y":2025,"v":559800,"taxable":111960,"land":111960,"improvement":447840,"taxableLand":111960,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":447840},{"y":2026,"v":559800,"taxable":522480,"land":111960,"improvement":447840,"taxableLand":111960,"taxableImprovement":410520,"exemptLand":0,"exemptImprovement":37320},{"y":2027,"v":606900,"taxable":506900,"land":121380,"improvement":485520,"taxableLand":121380,"taxableImprovement":385520,"exemptLand":0,"exemptImprovement":100000}],"taxNow":7314,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"183103","date":"2008-10-29","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2008-10-29","scope":"USE AS AN AMBULANCE COMPANY WITH STORAGE AND DISPATCHING OF AMBULANCES, ACCESSORY OFFICE, AND ACCESSARY MINOR REPAIRS TO COMPANY VEHICLES ONLY."},{"number":"390280","date":"2012-04-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-07-02","scope":"INSTALLATION OF NEW 6\" BACKFLOW PREVENTION DEVICE IN ACCORDANCE WITH NFPA 13 AS PART OF AN EXISTING SPRINKLER SYSTEM SERVING A ONE (1) STORY STRUCTURE (AMBULANCE FACILITY)."},{"number":"390356","date":"2012-04-09","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-10-31","scope":"INSTALL NEW BACKFLOW PREVENTER TO DOMESTIC WATER SERVICE(COMMERCIAL)"},{"number":"568343","date":"2014-12-15","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2014-12-15","scope":"FOR THE COMPLETE DEMOLITION OF ALL EXISTING STRUCTURES. FOR THE LOT ADJUSTMENT TO CREATE ONE (1) LOT FROM FIFTEEN (15) DEEDED PARCELS (1346-1348 MASCHER STREET, 1350 MASCHER STREET, 1352-1356 MASCHER STREET, 160 W MASTER STREET, 162 W MASTER STREET, 164 W MASTER STREET, 166 W MASTER STREET, 168 W MASTER STREET. 1339 N HANCOCK STREET, 1341 N HANCOCK STREET, 1343 N HANCOCK STREET, 1345 N HANCOCK STREET, 1349 N HANCOCK STREET, 1351 N HANCOCK STREET, 1353 N HANCOCK STREET) AND SIX (6) OPA ACCOUNTS (1346-48 MASCHER STREET, 150-68 MASTER STREET, 1353 N HANCOCK STREET, 1351 N HANCOCK STREET, 1345-49 N HANCOCK STREET, AND 1339-43 N HANCOCK STREET). SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS."},{"number":"582114","date":"2015-01-05","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2015-01-05","scope":"FOR THE ERECTION OF THREE (3) BUILDINGS [1 ATTACHED STRUCTURE (BUILDING 2) AND TWO (2) SEMI-DETACHED STRUCTURES (BUILDINGS 1 AND 3)]. EACH STRUCTURE WITH ROOF DECKS AND PILOT HOUSES (TO ENCLOSE ACCESS STAIRS ONLY). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (TWENTY (20) DWELLING UNITS TOTAL) WITH FOUR (4) UNITS IN BUILDING 1, TEN (10) UNITS IN BUILDING 2, AND SIX (6) UNITS IN BUILDING 3., WITH TWENTY-FOUR (24) ACCESSORY, OFF-STREET PARKING SPACES (TWENTY (20) INTERIOR SPACES AND FOUR (4) SURFACE PARKING SPACES). NO SIGNS ON APPLICATION. SEE A/P NO 568343"},{"number":"583134","date":"2015-02-02","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-04-28","scope":"FOR THE COMPLETE DEMOLITION OF MULTIPLE STRUCTURES, WITH THE INSTALLATION OF TIEBACK ANCHORS AT EXISTING MASONRY PARTY WALL (AT 1344 MASCHER ST), SEPARATION OF STRUCTURE FROM PARTY WALL, AND MACHINE DEMOLITION AS PER SAFETY WORK PLAN AND ENGINEER'S SURVEY AND RECOMMENDATIONS. PEDESTRIAN PROTECTION TO BE PROVIDED IN ACCORDANCE WITH B-3306. SIDEWALK CLOSURE PERMIT TO BE OBTAINED PRIOR TO COMMENCEMENT OF DEMOLITION WORK."},{"number":"603690","date":"2015-05-05","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-01-07","scope":"UNDERPINNING FOR PREPARATION FOR SINGLE FAMILY DWELLING-BUILDING #1(\"1350\")-TO PREPARE FOR FOUNDATIONS (SEPARATE APPROVAL NEEDED FOR FOUNDATION-UNDER AP# 588288). NO WORK FOR FOUNDATIONS ON THIS PERMIT(UNDERPINNING ONLY) ENGINEER ON SITE TO MONITOR AND SUPERVISE THE UNDERPINNING."},{"number":"588288","date":"2015-05-07","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-03-19","scope":"FOR THE CONSTRUCTION OF FOUNDATIONS FOR SINGLE FAMILY DWELLING (UNITS 1-4; UNITS 15-20) AS SHOWN PER APPROVED PLANS. IF FIELD CONDITIONS VARY, CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. AMMENDED PERMIT REQUIRED FOR SPECIAL INSPECTIONS."},{"number":"613999","date":"2015-06-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-06-17","scope":"UNDERSLAB INSTALLATION OF PLUMBING SOIL/WASTE PIPING AND A SEWER EJECTOR ROUGH-IN FOR NEW SINGLE FAMILY DWELLINGS UNITS #1, 2, 3 & 4 AND UNITS #15, 16, 17, 18, 19 & 20 - ADDITIONAL PERMITS REQUIRED FOR INTERIOR ABOVE-SLAB AND EXTERIOR PLUMBING/SITEWORK"},{"number":"613410","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-01-07","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. FOUNDATION PLANS UNDER PERMIT #588288. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION."},{"number":"617116","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2015-11-19","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617117","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-03-01","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617118","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-02-26","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617119","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-02-26","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617120","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617121","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617122","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-03-24","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617115","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2015-11-19","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 588288 FOR FOUNDATION. SEE APP 613410 FOR PLANS."},{"number":"617114","date":"2015-06-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2015-12-09","scope":"FOR NEW CONSTRUCTION OF A THREE(3) STORY WOOD FRAMED SINGLE FAMILY DWELLING WITH FLAT ROOF, FULL CELLAR, UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE. PART OF A NEW COMPOUND WITH TWENTY(20) UNITS. FOUNDATION PERMITS UNDER APPLICATION #588288. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE APP 613410 FOR PLANS."},{"number":"620857","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-01-07","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620867","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-12-09","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620868","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-11-18","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620869","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-11-18","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620871","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-02-26","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620872","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-02-26","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620874","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620875","date":"2015-07-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-23","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"631203","date":"2015-08-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-11-18","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180548 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631204","date":"2015-08-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-11-18","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180548 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631202","date":"2015-08-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-12-09","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180548 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631197","date":"2015-08-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-01-07","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180548 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"620873","date":"2015-08-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-14","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"620870","date":"2015-08-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-01","scope":"INSTALLATION OF NFPA 13D SPRINKLER SYSTEM FOR RESIDENTIAL BUILDING. 1\" COMBINED SERVICE. CODE/DESIGN PROF: PHILIP SCONYO, PE"},{"number":"631405","date":"2015-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180560 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631401","date":"2015-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-02-26","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180548 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631400","date":"2015-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180548 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631402","date":"2015-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-02-26","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180548 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631403","date":"2015-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-01","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180560 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"631404","date":"2015-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAV,KS,1 WASHER BOX,1 TUB/SHOWER,1 SHOWER AND WH,CURB TRAP,FAI,LATERAL,WATER SERVICE PA20152180560 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"637095","date":"2015-09-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-01-28","scope":"INSTALL 200 AMP MAIN SERVICE,INSTALL 40 CIRCUIT MAIN BREAKER PANEL, INSTALL ALLWIRING THROUGHOUT SINGLE FAMILY,INSTALL 120V SMOKE & CO DETECTORS AS PER 2008 NEC (EAST DISTRICT)"},{"number":"637094","date":"2015-09-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-02-15","scope":"INSTALL 200 AMP MAIN SERVICE,INSTALL 40 CIRCUIT MAIN BREAKER PANEL, INSTALL ALLWIRING THROUGHOUT SINGLE FAMILY,INSTALL 120V SMOKE & CO DETECTORS AS PER 2008 NEC (EAST DISTRICT)"},{"number":"626775","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE"},{"number":"630059","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630060","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630061","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2017-01-05","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630062","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-09-15","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630063","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-09-15","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630064","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-09-20","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630065","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-11-22","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630066","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-11-10","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"630067","date":"2015-09-09","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2016-11-02","scope":"NEW CONSTRUCTION. 4 STORY WOOD FRAMED S.F.D., MAX HT 44'-0\", FLAT ROOF, FULL CELLAR UPPER LEVEL ROOF DECK WITH ACCESS FROM PILOT HOUSE SEE AP# 626775 FOR APPROVED PLANS"},{"number":"638681","date":"2015-09-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-05","scope":"INSTALL 10 4 TON SYTEMS WITH 100,000. BTU FORCED AIR HEATERS ON 3RD FL,EACH UNIT HAS A 4 TON SYSTEM (UNITS 1 THRU 4) AND (UNITS 15 THRU 20)"},{"number":"645036","date":"2015-10-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-17","scope":"INSTALL 200 AMP MAIN SERVICE,INSTALL 40 CIRCUIT MAIN BREAKER PANEL, INSTALL ALLWIRING THROUGHOUT SINGLE FAMILY,INSTALL 120V SMOKE & CO DETECTORS AS PER 2008 NEC (EAST DISTRICT)"},{"number":"645035","date":"2015-10-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-31","scope":"INSTALL 200 AMP MAIN SERVICE,INSTALL 40 CIRCUIT MAIN BREAKER PANEL, INSTALL ALLWIRING THROUGHOUT SINGLE FAMILY,INSTALL 120V SMOKE & CO DETECTORS AS PER 2008 NEC (EAST DISTRICT)"},{"number":"651871","date":"2015-11-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAVS,2 TUB/SHOWERS,1 KITCHEN SINK,1 WASHER BOX AND WATER HEATER (SFD)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"651875","date":"2015-11-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAVS,2 TUB/SHOWERS,1 KITCHEN SINK,1 WASHER BOX AND WATER HEATER (SFD)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"651874","date":"2015-11-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAVS,2 TUB/SHOWERS,1 KITCHEN SINK,1 WASHER BOX AND WATER HEATER (SFD)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"651879","date":"2015-11-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAVS,2 TUB/SHOWERS,1 KITCHEN SINK,1 WASHER BOX AND WATER HEATER (SFD)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"651877","date":"2015-11-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAVS,2 TUB/SHOWERS,1 KITCHEN SINK,1 WASHER BOX AND WATER HEATER (SFD)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"651876","date":"2015-11-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-11","scope":"3 WC,4 LAVS,2 TUB/SHOWERS,1 KITCHEN SINK,1 WASHER BOX AND WATER HEATER (SFD)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"662442","date":"2016-01-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-02-15","scope":"INSTALL 200 AMP MAIN SERVICE- INSTALL 40 CIRCUIT MB PANEL. INSTALL ALL WIRING THROUGHOUT AS PER 2008 NEC. INSTALL PHONE AND CABLE TV WIRING"},{"number":"662444","date":"2016-01-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-27","scope":"INSTALL 200 AMP MAIN SERVICE- INSTALL 40 CIRCUIT MB PANEL. INSTALL ALL WIRING THROUGHOUT AS PER 2008 NEC. INSTALL PHONE AND CABLE TV WIRING"},{"number":"662443","date":"2016-01-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-27","scope":"INSTALL 200 AMP MAIN SERVICE- INSTALL 40 CIRCUIT MB PANEL. INSTALL ALL WIRING THROUGHOUT AS PER 2008 NEC. INSTALL PHONE AND CABLE TV WIRING"},{"number":"663037","date":"2016-01-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-27","scope":"INSTALL 200AMP MAIN SERVICE- INSTALL 40 CIRCUIT MB PANEL,INSTALL PHONE AND CABLE TV WIRING,INSTALL ALL WIRING THROUGHOUT AS PER 2008 NEC (EAST DISTRICT)"},{"number":"663347","date":"2016-01-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-14","scope":"NEW CONSTRUCTION - INSTALL 200 AMP MAIN SERVICE - INSTALL 40 CIRCUIT MB PANEL. INSTALL ALL WIRING THROUGHOUT SWITCHES, RECEPTS, LIGHTS INTERCONNECTED SMOKES/CO DETECTORS, PHONE & CABLE TV WIRING AS PER 2008 NEC (EAST DISTRICT)"},{"number":"663348","date":"2016-01-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-05-25","scope":"NEW CONSTRUCTION - INSTALL 200 AMP MAIN SERVICE - INSTALL 40 CIRCUIT MB PANEL. INSTALL ALL WIRING THROUGHOUT SWITCHES, RECEPTS, LIGHTS INTERCONNECTED SMOKES/CO DETECTORS, PHONE & CABLE TV WIRING AS PER 2008 NEC (EAST DISTRICT)"},{"number":"684997","date":"2016-04-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-11-02","scope":"INSTALL TEN 60,000 92% FORCED AIR FURNACE IN BASEMENT FOR EACH UNIT 5 THRU 14 NEW DUCT WORK,INSTALL 10 60,000 92 FORCED AIR FURNACE IN MECH ROOM ON THIRD FLOOR FOR EACH UNIT 5 THRU 14 WITH NEW DUCT WORK."},{"number":"684602","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS."},{"number":"684622","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684623","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684624","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-01-05","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684625","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-09-14","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684626","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-09-14","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684627","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-09-20","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684628","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-11-22","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684629","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-11-10","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"684630","date":"2016-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-11-02","scope":"FOR THE INSTALLATION OF A (1-1/2) INCH FIRE SERVICE LINE W. BACKFLOW PREVENTOR (BFP) ASSEMBLY AND FOR INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13R. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS. SEE AP#684602 FOR APPROVED PLANS AND SUPPLEMENTAL DOCUMENTS."},{"number":"673623","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS"},{"number":"673626","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673627","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673628","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-01-05","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673629","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-09-14","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673630","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-09-14","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673631","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-09-20","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673632","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-11-22","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673633","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-11-10","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"673634","date":"2016-05-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-11-02","scope":"SANITARY DRAINAGE AND WATER SUPPLY PIPING THROUGHOUT FOR A NEW (4)STORY SINGLE-FAMILY DWELLING INCLUDING THE SANITARY SEWER AND DOMESTIC WATER CONNECTIONS TO THE CITY MAINS - NOTE: BUILDING STORM AND STORM SITEWORK REQUIRE SEPARATE PERMITS - INSTALLATION PER THE APPROVED PLANS FILED WITH APPLICATION #673626"},{"number":"697002","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697003","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697004","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-30","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697005","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-01-05","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697006","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-10-26","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697008","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-01","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697007","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-10-26","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697009","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-02-15","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697010","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-11-10","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"697011","date":"2016-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-11-02","scope":"INSTALL 200A MAIN SERVICE WITH 40- CIRCUIT PANEL, ALL WIRING THROUGHOUT, 120V SMOKES AND C/O DETECTORS, INSTALL PHONE AND CABLE TV WIRING... IN ACCORDANCE WITH 2008 NEC FOR A ONE FAMILY BUILDING"},{"number":"701062","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-08-25","scope":"UJHFIDASUFSODIFOH"},{"number":"705379","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-08-25","scope":"UJHFIDASUFSODIFOH"},{"number":"705380","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-08-25","scope":"UJHFIDASUFSODIFOH"},{"number":"705381","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-09-19","scope":"UJHFIDASUFSODIFOH"},{"number":"705382","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-09-19","scope":"UJHFIDASUFSODIFOH"},{"number":"705383","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-09-19","scope":"UJHFIDASUFSODIFOH"},{"number":"705384","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-09-19","scope":"UJHFIDASUFSODIFOH"},{"number":"705385","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-09-19","scope":"UJHFIDASUFSODIFOH"},{"number":"705386","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-09-19","scope":"UJHFIDASUFSODIFOH"},{"number":"705387","date":"2016-07-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-09-19","scope":"UJHFIDASUFSODIFOH"}],"storyTag":"Torn down & rebuilt","storyDelta":null,"timeline":[{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"permit","w":"Administrative"},{"y":2016,"k":"insp","w":"L&I: 5 failed, 5 passed"},{"y":2025,"k":"sale","p":700000}],"rented":false,"licenses":[{"number":"735579","type":"Rental","status":"Inactive","businessName":"Alyssa  Han","legalName":"Alyssa  Han","address":"1346 MASCHER ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":1,"issuedDate":"2017-04-18","latestIssueDate":"2019-05-06","expirationDate":"2020-04-17","inactiveDate":"2020-06-16"}],"licenseActivity":[{"number":"735579","type":"Rental","businessName":"Alyssa  Han","legalName":"Alyssa  Han","issuedDate":"2017-04-18","latestIssueDate":"2019-05-06","closureDate":"2020-06-16","expirationDate":"2020-04-17","inactiveDate":"2020-06-16","status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #183103: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"8 failed, 7 passed, and 4 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Oct 25, 2016.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"homestead","level":"verify","title":"Homestead is tied to owner occupancy and the deed","finding":"OPA shows the Homestead Exemption.","why":"Philadelphia limits Homestead to an owner’s primary residence. The City says a deed change can require a new application or update.","action":"A buyer should apply in their own name and not assume the seller’s benefit continues.","url":"https://www.phila.gov/documents/homestead-exemption-application/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 28 historical violations across 19 cases.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"},{"title":"Seller-specific tax relief is not the buyer’s bill","body":"LOOP and low-income or senior Real Estate Tax freezes depend on the qualifying owner and continued program eligibility; a buyer cannot assume the seller’s capped or frozen bill continues. A separately verified property abatement often remains with the property for its remaining term, but program-specific new-owner filing, use, and tax-compliance conditions still must be confirmed—not inferred from the reduced assessment alone.","action":"Have Revenue or OPA identify every current benefit, model the buyer’s bill without seller-specific relief, and confirm any verified abatement in writing.","url":"https://www.phila.gov/services/payments-assistance-taxes/payment-plans-and-assistance-programs/income-based-programs-for-residents/apply-for-the-longtime-owner-occupants-program-loop/","secondaryUrl":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/tax-freeze/"},{"title":"Seller disclosure and independent inspections","body":"For a covered Pennsylvania residential transfer, obtain the statutory seller disclosure. It reports the seller’s knowledge; it is not a warranty, title search, code review, or substitute for inspections.","action":"Have the agreement and disclosure reviewed for this transaction’s coverage and exceptions.","url":"https://www.pa.gov/agencies/dos/department-and-offices/bpoa/boards-commissions/real-estate-commission"}]}