{"asOf":"2026-07-29T09:11:23.765Z","block":"4300-4399 DEXTER ST","blockUrl":"https://philadelphia.blockreport.homes/block/4300-4399-dexter-st","address":"4334 DEXTER ST","parcelNumber":"211319600","source":"https://property.phila.gov/?p=211319600","ownerType":"investor","kind":"house","isHouse":true,"home":true,"commercial":false,"residential":true,"taxExempt":false,"institutional":false,"buildingCode":"P58","buildingCodeNew":"26","buildingClass":"ROW W/GAR 3 STY STONE","buildingClassNew":"ROW RIVER ROW","useLabel":"House","owner":"JET STREAM REALTY GROUP L","coOwner":null,"marketValue":535200,"landAssessment":107040,"improvementAssessment":428160,"livableArea":3217,"yearBuilt":1930,"lastSale":{"price":155000,"date":"2015-03-06T05:00:00Z"},"openViolations":0,"violations":[],"violationCases":[],"investigations":[],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":40.028095844271235,"lng":-75.21860245146426,"geom":{"type":"Polygon","coordinates":[[[-75.218676144,40.028038819],[-75.218727433,40.02801577],[-75.218753059,40.02804551],[-75.218492709,40.028175015],[-75.218460284,40.028135838],[-75.218676144,40.028038819]]]},"liDistrict":"NORTH","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19128","beds":4,"baths":1,"stories":3,"lotArea":1478,"zoning":"RSA5","grade":"B-","basement":"I","heater":"B","centralAir":false,"extCond":"3","intCond":"3","garage":1,"homestead":false,"mail":"1347 FORDING BROOK RD, LOWER GWYNEDD PA, 19002","mailOut":true,"appeals":[],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":2,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":431200,"taxable":251200,"land":27045,"improvement":404155,"taxableLand":27045,"taxableImprovement":224155,"exemptLand":0,"exemptImprovement":180000},{"y":2017,"v":431200,"taxable":251200,"land":62500,"improvement":368700,"taxableLand":62500,"taxableImprovement":188700,"exemptLand":0,"exemptImprovement":180000},{"y":2018,"v":431200,"taxable":251200,"land":62500,"improvement":368700,"taxableLand":62500,"taxableImprovement":188700,"exemptLand":0,"exemptImprovement":180000},{"y":2019,"v":436500,"taxable":254287,"land":63268,"improvement":373232,"taxableLand":63268,"taxableImprovement":191019,"exemptLand":0,"exemptImprovement":182213},{"y":2020,"v":444100,"taxable":258680,"land":64300,"improvement":379800,"taxableLand":64300,"taxableImprovement":194380,"exemptLand":0,"exemptImprovement":185420},{"y":2021,"v":444100,"taxable":258680,"land":64300,"improvement":379800,"taxableLand":64300,"taxableImprovement":194380,"exemptLand":0,"exemptImprovement":185420},{"y":2022,"v":444100,"taxable":258680,"land":64300,"improvement":379800,"taxableLand":64300,"taxableImprovement":194380,"exemptLand":0,"exemptImprovement":185420},{"y":2023,"v":403600,"taxable":245389,"land":80720,"improvement":322880,"taxableLand":80720,"taxableImprovement":164669,"exemptLand":0,"exemptImprovement":158211},{"y":2024,"v":403600,"taxable":245389,"land":80720,"improvement":322880,"taxableLand":80720,"taxableImprovement":164669,"exemptLand":0,"exemptImprovement":158211},{"y":2025,"v":464300,"taxable":282294,"land":92860,"improvement":371440,"taxableLand":92860,"taxableImprovement":189434,"exemptLand":0,"exemptImprovement":182006},{"y":2026,"v":464300,"taxable":464300,"land":92860,"improvement":371440,"taxableLand":92860,"taxableImprovement":371440,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":535200,"taxable":535200,"land":107040,"improvement":428160,"taxableLand":107040,"taxableImprovement":428160,"exemptLand":0,"exemptImprovement":0}],"taxNow":6499,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"595239","date":"2015-03-11","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-04-08","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"595841","date":"2015-03-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-04-08","scope":"EZ PERMIT STADARD ALTERATIONS- FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"596234","date":"2015-03-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-06-22","scope":"EZ PERMIT STADARD ALTERATIONS- (TO CORRECT THE RENOVATION AREA UNDER PERMIT # 595841) FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"597348","date":"2015-03-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-07-19","scope":"REPLACE WATER SUPPLY, SOIL PIPING, INSTALL FIXTURES - ALL WORK TO COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"601562","date":"2015-04-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-10-16","scope":"200 AMPS SERVICE, 110 SMOKES, 5-15 AMP CIRCUITS, 6-20 AMP CIRCUITS-2008 NEC (SFD)"},{"number":"609738","date":"2015-05-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-10-27","scope":"INSTALLING 2 ZONES OF HVAC TO HEAT AND COOL PROPERTY. UNITS ARE DIRECT VENT FURNACES WITH CENTRAL AC ATTACHED TO THEM. ONE FURNACE WILL BE LOCATES IN THE LAUNDRY ROOM ON THE 3RD FLOOR SERVICING THE 2ND AND 3RD FLOOR ONLY. THE SECOND FURNACE WILL BE LOCATED IN THE BASEMENT. THE CONDENSERS WILL BE LOCATED ON A PLATFORM SUPPLIED AND LOCATED BY THE GENERAL CONTRACTOR."},{"number":"606441","date":"2015-06-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-10-28","scope":"INSTALLATION OF A DECK ON TOP OF THE FIRST FLOOR PORTION OF THE ATTACHED GARAGE ROOF, AND A SECOND STORY DECK ATOP OF THE SINGLE STORY SECTION OF HOUSE. WORK TO INCLUDE RENOVATION OF INTERIOR SPACES AS PER APPROVED PLANS AND ENGINEER'S RECOMENDATIONS. AS PART OF AN ATTACHED SINGLE FAMILY DWELLING."},{"number":"612221","date":"2015-06-18","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2015-06-18","scope":"ERECTION OF A DECK ON TOP OF FIRST FLOOR ATTACHED GARAGE ROOF, AND A SECOND STORY DECK ATOP OF THE SINGLE STORY SECTION OF HOUSE."},{"number":"MP-2023-003953","date":"2023-09-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-09-27","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. REPLACE IN LIKE AND KIND, BRYANT 2.5 TON AC UNIT AND EVAPORATOR COIL. NO DIFFUSERS OR DUCTWORK BEING INSTALLED. ANY DUCTWORK WILL REQUIRE A VALID BUILDING PERMIT"}],"storyTag":"Improved","storyDelta":1.58,"timeline":[{"y":2000,"k":"sale","p":60000},{"y":2015,"k":"sale","p":155000},{"y":2015,"k":"permit","w":"Demolition"},{"y":2015,"k":"permit","w":"Major alteration"},{"y":2015,"k":"permit","w":"Major alteration"},{"y":2015,"k":"permit","w":"Plumbing"},{"y":2015,"k":"permit","w":"Electrical"},{"y":2015,"k":"permit","w":"Mechanical"},{"y":2015,"k":"permit","w":"Major alteration"},{"y":2015,"k":"permit","w":"Zoning"},{"y":2023,"k":"permit","w":"Addition and/or Alterations"}],"rented":true,"licenses":[{"number":"731993","type":"Rental","status":"Active","businessName":"JET STREAM REALTY GROUP LLC","legalName":"JET STREAM REALTY GROUP LLC","address":"4334 DEXTER ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":1,"issuedDate":"2017-03-17","latestIssueDate":"2026-03-25","expirationDate":"2027-03-16","inactiveDate":null}],"licenseActivity":[{"number":"731993","type":"Rental","businessName":"JET STREAM REALTY GROUP LLC","legalName":"JET STREAM REALTY GROUP LLC","issuedDate":"2017-03-17","latestIssueDate":"2026-03-25","closureDate":null,"expirationDate":"2027-03-16","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true}],"businessLicenseSourceDate":"2026-07-28","signals":[],"legalChecks":[{"id":"rental-license","level":"verify","title":"A rental license does not transfer with the deed","finding":"1 active Rental License record matched.","why":"If dwelling space is rented, the buyer must obtain a new annual Rental License; the seller’s license is not transferable. New applications require proof of ownership and legal occupancy, tax compliance, no open L&I violations, and lead compliance where applicable.","action":"Plan the buyer’s replacement license before settlement.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"managing-agent","level":"verify","title":"Tax mail goes outside Philadelphia; owner residence still needs verification","finding":"OPA mails the property tax record outside Philadelphia (1347 FORDING BROOK RD, LOWER GWYNEDD PA, 19002).","why":"A tax mailing destination does not establish where the owner lives. If a rental owner lives outside Philadelphia, the City requires a managing agent with a Philadelphia mailing address; the owner remains legally responsible.","action":"Verify the buyer’s residence and, if the buyer will live outside Philadelphia, identify the Philadelphia managing agent on the new license application.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"lead","level":"verify","title":"Lead compliance is a separate record","finding":"OPA records a 1930 build year; BlockReport does not receive the Health Department’s unit-level lead certificate file.","why":"Philadelphia requires covered pre-March-1978 rentals to be certified lead-safe or lead-free for a new or renewed lease and for a new or renewed Rental License. A certificate is unit-specific; a renovation does not by itself create an exemption.","action":"Request the current lead certificate or City exemption for every dwelling unit.","url":"https://www.phila.gov/documents/lead-and-healthy-homes-resources-for-landlords/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"},{"title":"Seller-specific tax relief is not the buyer’s bill","body":"LOOP and low-income or senior Real Estate Tax freezes depend on the qualifying owner and continued program eligibility; a buyer cannot assume the seller’s capped or frozen bill continues. A separately verified property abatement often remains with the property for its remaining term, but program-specific new-owner filing, use, and tax-compliance conditions still must be confirmed—not inferred from the reduced assessment alone.","action":"Have Revenue or OPA identify every current benefit, model the buyer’s bill without seller-specific relief, and confirm any verified abatement in writing.","url":"https://www.phila.gov/services/payments-assistance-taxes/payment-plans-and-assistance-programs/income-based-programs-for-residents/apply-for-the-longtime-owner-occupants-program-loop/","secondaryUrl":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/tax-freeze/"},{"title":"Seller disclosure and independent inspections","body":"For a covered Pennsylvania residential transfer, obtain the statutory seller disclosure. It reports the seller’s knowledge; it is not a warranty, title search, code review, or substitute for inspections. Because OPA dates this building before 1978, separately obtain the required federal/City lead disclosures and any test results.","action":"Have the agreement and disclosure reviewed for this transaction’s coverage and exceptions.","url":"https://www.pa.gov/agencies/dos/department-and-offices/bpoa/boards-commissions/real-estate-commission"}]}