{"asOf":"2026-07-26T09:03:46.890Z","block":"0-99 W UPSAL ST","blockUrl":"https://philadelphia.blockreport.homes/block/0-99-w-upsal-st","address":"45 W UPSAL ST","parcelNumber":"223020700","source":"https://property.phila.gov/?p=223020700","ownerType":"investor","kind":"house","isHouse":true,"home":true,"commercial":false,"residential":true,"taxExempt":true,"institutional":false,"buildingCode":"J40","buildingCodeNew":"36","buildingClass":"S/D W/D GAR 2.5 STY MASON","buildingClassNew":"TWIN OLD STYLE","useLabel":"House","owner":"DANNYS HOUSE","coOwner":null,"marketValue":575500,"landAssessment":115100,"improvementAssessment":460400,"livableArea":3212,"yearBuilt":1925,"lastSale":{"price":415000,"date":"2019-02-04T05:00:00Z"},"openViolations":0,"violations":[{"number":"499817","date":"2007-02-22","code":"PM-307.1/2","title":"ROOF DETERIORATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"499818","date":"2007-02-22","code":"PM-307.1/11","title":"WALL DETERIORATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"861244","date":"2008-03-05","code":"PM-306.2/1","title":"VACANT BLDG UNSECURED COUNT","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"861243","date":"2008-03-05","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"861220","date":"2008-03-05","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"1638984","date":"2009-04-13","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1638986","date":"2009-04-13","code":"PM-303.2/1","title":"INT A-TRASH REMOVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1638985","date":"2009-04-13","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1297953","date":"2009-04-14","code":"PM-307.1/19","title":"VACANT BLDG UNSEC/UNSAFE CSU","status":"ERROR","resolutionDate":null,"resolution":null},{"number":"2179121","date":"2011-07-13","code":"PM-302.3/1","title":"EXT A-CLEAN WEEDS/PLANTS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2615753","date":"2012-09-10","code":"PM-306.2/4","title":"VAC PROP REPLAC WIN/DRS 80%","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2615751","date":"2012-09-10","code":"PM-304.1/1","title":"EXT S-EXTERIOR REPAIR/MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2615752","date":"2012-09-10","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2662715","date":"2012-10-24","code":"PM-306.2/4","title":"VAC PROP REPLAC WIN/DRS 80%","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2662714","date":"2012-10-24","code":"PM-304.1/1","title":"EXT S-EXTERIOR REPAIR/MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2662713","date":"2012-10-24","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2861293","date":"2012-12-04","code":"A-301.1/70","title":"PERMB- APPL EXT STUCCO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2861292","date":"2012-12-04","code":"A-301.1/38","title":"PERMB- STRUCTURAL REPAIR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2861294","date":"2012-12-04","code":"A-301.6/1","title":"PERMB- TO COMPLY VIOL","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2984537","date":"2013-10-28","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2984536","date":"2013-10-28","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3588086","date":"2015-06-08","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3588087","date":"2015-06-08","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3938537","date":"2015-12-15","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4043842","date":"2016-06-07","code":"PM15-302.4","title":"EXTERIOR AREA WEEDS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4043841","date":"2016-06-07","code":"PM15-301","title":"VACANT STRUCTURE AND LAND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4298483","date":"2017-05-02","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4298482","date":"2017-05-02","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4442070","date":"2017-08-10","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4442069","date":"2017-08-10","code":"A-504.1/3","title":"SWO- CONSTR W/O BLDG PERMIT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4442068","date":"2017-08-10","code":"A-301.1/7","title":"PERMB- INT DEMOL WALLS ETC","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"102727","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":"2007-02-23","completedDate":"2009-08-19","violations":[{"number":"499817","date":"2007-02-22","code":"PM-307.1/2","title":"ROOF DETERIORATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"499818","date":"2007-02-22","code":"PM-307.1/11","title":"WALL DETERIORATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"149685","type":"STANDARD","priority":"STANDARD","responsibility":"BRU","status":"CLOSED","createdDate":"2008-03-05","completedDate":"2008-08-30","violations":[{"number":"861244","date":"2008-03-05","code":"PM-306.2/1","title":"VACANT BLDG UNSECURED COUNT","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"861243","date":"2008-03-05","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"861220","date":"2008-03-05","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"196112","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2009-04-14","completedDate":"2010-05-14","violations":[{"number":"1638984","date":"2009-04-13","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1638986","date":"2009-04-13","code":"PM-303.2/1","title":"INT A-TRASH REMOVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1638985","date":"2009-04-13","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"196137","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2009-04-14","completedDate":"2017-08-11","violations":[{"number":"1297953","date":"2009-04-14","code":"PM-307.1/19","title":"VACANT BLDG UNSEC/UNSAFE CSU","status":"ERROR","resolutionDate":null,"resolution":null}]},{"number":"286680","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2011-07-13","completedDate":"2011-10-26","violations":[{"number":"2179121","date":"2011-07-13","code":"PM-302.3/1","title":"EXT A-CLEAN WEEDS/PLANTS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"349126","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2012-09-10","completedDate":"2012-10-24","violations":[{"number":"2615753","date":"2012-09-10","code":"PM-306.2/4","title":"VAC PROP REPLAC WIN/DRS 80%","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2615751","date":"2012-09-10","code":"PM-304.1/1","title":"EXT S-EXTERIOR REPAIR/MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2615752","date":"2012-09-10","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"356924","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2012-10-24","completedDate":"2013-03-08","violations":[{"number":"2662715","date":"2012-10-24","code":"PM-306.2/4","title":"VAC PROP REPLAC WIN/DRS 80%","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2662714","date":"2012-10-24","code":"PM-304.1/1","title":"EXT S-EXTERIOR REPAIR/MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2662713","date":"2012-10-24","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"361651","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DN","status":"CLOSED","createdDate":"2012-12-04","completedDate":"2015-02-04","violations":[{"number":"2861293","date":"2012-12-04","code":"A-301.1/70","title":"PERMB- APPL EXT STUCCO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2861292","date":"2012-12-04","code":"A-301.1/38","title":"PERMB- STRUCTURAL REPAIR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2861294","date":"2012-12-04","code":"A-301.6/1","title":"PERMB- TO COMPLY VIOL","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"408855","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2013-10-28","completedDate":"2014-02-26","violations":[{"number":"2984537","date":"2013-10-28","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2984536","date":"2013-10-28","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"484432","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2015-06-08","completedDate":"2016-01-20","violations":[{"number":"3588086","date":"2015-06-08","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3588087","date":"2015-06-08","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"514481","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-12-18","completedDate":"2018-12-06","violations":[{"number":"3938537","date":"2015-12-15","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"537682","type":"STANDARD","priority":"STANDARD","responsibility":"VS","status":"CLOSED","createdDate":"2016-06-08","completedDate":"2017-10-10","violations":[{"number":"4043842","date":"2016-06-07","code":"PM15-302.4","title":"EXTERIOR AREA WEEDS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4043841","date":"2016-06-07","code":"PM15-301","title":"VACANT STRUCTURE AND LAND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"581645","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2017-05-02","completedDate":"2017-05-24","violations":[{"number":"4298483","date":"2017-05-02","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4298482","date":"2017-05-02","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"598794","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DN","status":"CLOSED","createdDate":"2017-08-10","completedDate":"2017-09-13","violations":[{"number":"4442070","date":"2017-08-10","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4442069","date":"2017-08-10","code":"A-504.1/3","title":"SWO- CONSTR W/O BLDG PERMIT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4442068","date":"2017-08-10","code":"A-301.1/7","title":"PERMB- INT DEMOL WALLS ETC","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2007,"n":2,"worst":null},{"y":2008,"n":3,"worst":null},{"y":2009,"n":4,"worst":"VACANT BLDG UNSEC/UNSAFE CSU"},{"y":2011,"n":1,"worst":null},{"y":2012,"n":9,"worst":null},{"y":2013,"n":2,"worst":null},{"y":2015,"n":3,"worst":null},{"y":2016,"n":2,"worst":null},{"y":2017,"n":5,"worst":null}],"investigations":[{"caseNumber":"73820","date":"2006-08-04","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"102727","date":"2007-02-22","type":"CSUINITIAL","status":"CLOSED"},{"caseNumber":"149685","date":"2008-03-05","type":"BRU INSP","status":"FAILED"},{"caseNumber":"149685","date":"2008-08-30","type":"BRU INSP","status":"CLOSED"},{"caseNumber":"73820","date":"2008-11-04","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"196112","date":"2009-04-13","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"196137","date":"2009-04-14","type":"CSUINITIAL","status":"CLOSED"},{"caseNumber":"196112","date":"2010-01-29","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"73820","date":"2010-04-05","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"196112","date":"2010-04-05","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"196112","date":"2010-05-12","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"286680","date":"2011-07-13","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"286680","date":"2011-08-15","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"286680","date":"2011-10-20","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"349126","date":"2012-09-10","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"349126","date":"2012-10-15","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"349126","date":"2012-10-24","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"356924","date":"2012-10-24","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"361651","date":"2012-12-04","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"356924","date":"2012-12-06","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"361651","date":"2013-02-11","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"356924","date":"2013-03-05","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"361651","date":"2013-03-18","type":"BP_BLDG","status":"CLOSED"},{"caseNumber":"361651","date":"2013-11-22","type":"PRECOURT","status":"PASSED"},{"caseNumber":"514481","date":"2015-12-15","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"514481","date":"2016-02-05","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"514481","date":"2016-03-15","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"514481","date":"2016-05-17","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"537682","date":"2016-06-07","type":"VAC INSP","status":"FAILED"},{"caseNumber":"537682","date":"2016-08-08","type":"VAC INSP","status":"FAILED"},{"caseNumber":"537682","date":"2016-10-06","type":"VAC INSP","status":"CLOSED"},{"caseNumber":"598794","date":"2017-09-01","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"598794","date":"2017-09-13","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"514481","date":"2018-12-05","type":"PRECOURT","status":"PASSED"}],"inspYears":[{"y":2006,"fails":1,"passes":0},{"y":2008,"fails":2,"passes":0},{"y":2009,"fails":1,"passes":0},{"y":2010,"fails":1,"passes":0},{"y":2011,"fails":2,"passes":0},{"y":2012,"fails":5,"passes":1},{"y":2013,"fails":1,"passes":2},{"y":2015,"fails":1,"passes":0},{"y":2016,"fails":3,"passes":0},{"y":2017,"fails":1,"passes":1},{"y":2018,"fails":0,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":40.046991950424605,"lng":-75.18522964558858,"geom":{"type":"Polygon","coordinates":[[[-75.18494449,40.046875658],[-75.18501661,40.046804907],[-75.185515074,40.047108269],[-75.185441873,40.047178706],[-75.18494449,40.046875658]]]},"liDistrict":"NORTH","certifications":[{"number":"BC-2023-005084","type":"Sprinkler Certification","inspectionDate":"2022-12-08","result":"Certified","expirationDate":"2023-12-08","buildingId":"1149897"},{"number":"BC-2023-025712","type":"Sprinkler Certification","inspectionDate":"2023-11-17","result":"Certified","expirationDate":"2024-11-17","buildingId":"1149896"},{"number":"BC-2025-009518","type":"Sprinkler Certification","inspectionDate":"2024-11-07","result":"Certified","expirationDate":"2025-11-07","buildingId":"1149896"},{"number":"BC-2025-031476","type":"Sprinkler Certification","inspectionDate":"2025-11-05","result":"Certified","expirationDate":"2026-11-05","buildingId":"1149896"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19119","beds":4,"baths":3,"stories":3,"lotArea":5768,"zoning":"RSA2","grade":"B+","basement":"D","heater":"A","centralAir":true,"extCond":"2","intCond":"2","garage":1,"homestead":false,"mail":"10 PADDOCK CIR, HORSHAM PA, 19044","mailOut":true,"appeals":[],"taxYears":[{"year":2016,"total":3164.59,"principal":2531.86,"interest":37.98,"penalty":25.32}],"taxNet":3164.59,"taxLien":true,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":1,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":194300,"taxable":164300,"land":118246,"improvement":76054,"taxableLand":118246,"taxableImprovement":46054,"exemptLand":0,"exemptImprovement":30000},{"y":2017,"v":194300,"taxable":164300,"land":32060,"improvement":162240,"taxableLand":32060,"taxableImprovement":132240,"exemptLand":0,"exemptImprovement":30000},{"y":2018,"v":194300,"taxable":164300,"land":32060,"improvement":162240,"taxableLand":32060,"taxableImprovement":132240,"exemptLand":0,"exemptImprovement":30000},{"y":2019,"v":439000,"taxable":399000,"land":72436,"improvement":366564,"taxableLand":72436,"taxableImprovement":326564,"exemptLand":0,"exemptImprovement":40000},{"y":2020,"v":420600,"taxable":420600,"land":63090,"improvement":357510,"taxableLand":63090,"taxableImprovement":357510,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":420600,"taxable":420600,"land":63090,"improvement":357510,"taxableLand":63090,"taxableImprovement":357510,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":420600,"taxable":420600,"land":63090,"improvement":357510,"taxableLand":63090,"taxableImprovement":357510,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":626300,"taxable":0,"land":125200,"improvement":501100,"taxableLand":0,"taxableImprovement":0,"exemptLand":125200,"exemptImprovement":501100},{"y":2024,"v":626300,"taxable":0,"land":125200,"improvement":501100,"taxableLand":0,"taxableImprovement":0,"exemptLand":125200,"exemptImprovement":501100},{"y":2025,"v":566800,"taxable":0,"land":113300,"improvement":453500,"taxableLand":0,"taxableImprovement":0,"exemptLand":113300,"exemptImprovement":453500},{"y":2026,"v":566800,"taxable":0,"land":113300,"improvement":453500,"taxableLand":0,"taxableImprovement":0,"exemptLand":113300,"exemptImprovement":453500},{"y":2027,"v":575500,"taxable":0,"land":115100,"improvement":460400,"taxableLand":0,"taxableImprovement":0,"exemptLand":115100,"exemptImprovement":460400}],"taxNow":0,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"410204","date":"2012-06-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"1200 SQUARE FEET OF INTERIOR ALTERATIONS - SINGLE FAMILY DWELLING - APPLICANT AGREES TO LIMIT THE CONSTRUCTION TO COMPLY WITH EZ PERMIT STANDARD FOR INTERIOR ALTERATIONS, DATED FEB. 2007. DEVIATIONS FROM THIS STANDARD WILL RESULT IN THE REVOCATION OF THIS PERMIT AND IMPOSITION OF FURTHER PENALTIES. LICENSED CONTRACTOR TO BE LISTED ON PERMIT SEPARATE PERMITS REQUIRED FOR PLUMBING, ELECTRIC AND HVAC. CALL INSPECTOR AT DISTRICT OFFICE AT LEAST 24 HOURS PRIOR TO STARTING WORK. REPLACE ALL WINDOWS AND DOORS, RE-SHINGLE ROOF 600 SQUARE FEET, REPLACE AND RE POINT BRICKS IN FRONT AND REAR YARD AND AROUND"},{"number":"807497","date":"2017-08-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-17","scope":"INSTALL NEW HIGH EFFICIENY GAS FORCED AIR FURNANCE AND AIR CONDITIONER"},{"number":"807471","date":"2017-08-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-07-31","scope":"EZ INTERIOR ALTERATIONS. APPLICANT AGREES TO LIMIT THE CONSTRUCTION TO COMPLY WITH EZ PERMIT STANDARD FOR INTERIOR ALTERATIONS, DATED JANUARY 2011. DEVIATION FROM THE STANDARD WILL RESULT IN REVOCATION OF THIS PERMIT AND IMPOSITION OF FURTHER PENALTIES. LICENSED CONTRACTOR TO BE LISTED ON PERMIT. SEPARATE PERMITS REQUIRED FOR PLUMBING, ELECTRIC AND HVAC. CALL INSPECTOR AT DISTRICT OFFICE AT LEAST 24 HOURS PRIOR TO START"},{"number":"819687","date":"2017-09-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-17","scope":"200AMP MAIN CABLES,200AMP METER,PANEL AND BREAKERS.NEW GROUNDING SYSTEMS,30 WALL OUTLETS,20 SWITCHES,25 LIGHT FIXTURES,10 SMOKES AND 8 GFCI OUTLETS PER 2008 NEC (SFD)"},{"number":"821402","date":"2017-10-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-07-31","scope":"4WC 5LAVS 2BT 1SHOWER 1 LAUNDRY 1KS 1DW 1GD 1HB 1WH"},{"number":"827310","date":"2017-10-26","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2017-10-26","scope":"INSTALL 10' X 14' DECK IN REAR. APPLICANT AGREES TO LIMIT THE CONSTRUCTION TO COMPLY WITH EZ PERMIT STANDARD FOR DECKS, DATED JANUARY 2011. DEVIATION FROM THE STANDARD WILL RESULT IN REVOCATION OF THIS PERMIT AND IMPOSITION OF FURTHER PENALTIES."},{"number":"827311","date":"2017-10-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-03-19","scope":"APPLICANT AGREES TO LIMIT THE CONSTRUCTION TO COMPLY WITH EZ PERMIT STANDARD FOR DECKS, DATED FEB. 2007. DEVIATIONS FROM THIS STANDARD WILL RESULT IN THE REVOCATION OF THIS PERMIT AND IMPOSITION OF FURTHER PENALTIES."},{"number":"855109","date":"2018-02-26","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-07-17","scope":"THE INSTALLATION OF NEW ROOF COVERINGS ON EXITING ROOFS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"854201","date":"2018-03-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-03-19","scope":"ROOF RENOVATIONS AS PER SEALED ENGINEERS PLANS"},{"number":"949815","date":"2019-05-31","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2019-05-31","scope":"THIS PERMIT IS HEREBY ISSUED BY TERMS OF A REASONABLE ACCOMMODATION, UNDER THE GUIDELINES OF THE FEDERAL FAIR HOUSING AMENDMENTS ACT, FOR A GROUP LIVING FOR MAXIMUM EIGHT (8) OCCUPANTS WITH TWO (2) STAFF MEMBERS (ONE STAFF MEMBER TO RESIDE ON THE PREMISES) IN AN EXISTING STRUCTURE. ALL OCCUPANTS ARE CAPABLE OF SELF PRESERVATION AND SELF SUSTAINING. NO OCCUPANTS UNDER THE JURISDICTION OF ANY COURT SYSTEM. NO SIGN ON THIS PERMIT."},{"number":"1043950","date":"2020-08-28","work":"Certificate of Occupancy (CO) (may inclu…","type":"Administrative","description":"Administrative Permit","status":"Completed","completedDate":"2023-03-15","scope":"FOR A CERTIFICATE OF OCCUPANCY FOR A GROUP HOME OCCUPANCY. ** NO ALTERATIONS APPROVED ON THIS PERMIT**. BUILDING SHALL COMPLY WITH THE PHILADELPHIA PROPERTY MAINTENANCE AND FIRE CODES PRIOR TO OCCUPANCY.**STRUCTURE TO BE SPRINKLERED PER NFPA 13D MIN**SEPARATE PERMITS REQUIRED FOR ALTERATIONS**."},{"number":"FP-2021-000016","date":"2021-08-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-03-15","scope":"INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13R WITH A FIRE DEPARTMENT CONNECTION, BACKKFLOW PREVENTION DEVICE AND 2\" SERVICE LINE, THROUGHOUT A THREE (3) STORY STRUCTURE. SEPARATE PERMIT REQUIRE FOR ALL PLUMBING WORK"}],"storyTag":"Improved","storyDelta":null,"timeline":[{"y":2017,"k":"permit","w":"Major alteration"},{"y":2017,"k":"permit","w":"Electrical"},{"y":2017,"k":"permit","w":"Plumbing"},{"y":2017,"k":"permit","w":"Zoning"},{"y":2017,"k":"permit","w":"Major alteration"},{"y":2018,"k":"permit","w":"Alteration"},{"y":2018,"k":"permit","w":"Major alteration"},{"y":2018,"k":"insp","w":"Inspection passed"},{"y":2019,"k":"sale","p":415000},{"y":2019,"k":"permit","w":"Use"},{"y":2020,"k":"permit","w":"Certificate of Occupancy (CO) (may inclu…"},{"y":2021,"k":"permit","w":"Addition and/or Alterations"}],"rented":false,"licenses":[{"number":"818942","type":"Rental","status":"Inactive","businessName":"Danny's House (Danny's House)","legalName":"Danny's House","address":"45 W UPSAL ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":1,"issuedDate":"2019-07-24","latestIssueDate":"2019-07-24","expirationDate":"2020-07-23","inactiveDate":"2020-09-21"}],"licenseActivity":[{"number":"818942","type":"Rental","businessName":"Danny's House (Danny's House)","legalName":"Danny's House","issuedDate":"2019-07-24","latestIssueDate":"2019-07-24","closureDate":"2020-09-21","expirationDate":"2020-07-23","inactiveDate":"2020-09-21","status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"permit-mismatch","level":"watch","title":"Assessment/permit mismatch","summary":"The assessment jumped 49% in 2023, but no matching permit appears in the property timeline.","evidence":["assessment moved from $420,600 to $626,300","no permit shown in 2022-2024"],"caveat":"Not proof of unpermitted work; reassessment, corrected data, or a permit under another parcel can also explain it."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #949815: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"1 permit not marked completed: 410204 (EXPIRED).","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"An unsafe-building history still deserves the repair file","finding":"The fetched record shows 0 open and 31 historical violations across 14 cases.","why":"The aggregate currently shows zero open violations, so a historical unsafe/imminently-dangerous row is not a current hazard finding. The repair or demolition permit, final inspection, and case closure are the evidence that resolves the former designation.","action":"Review the Make Safe/repair permit, final inspection, and case closure.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"18 failed, 5 passed, and 11 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Dec 5, 2018.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"full-tax-exemption","level":"verify","title":"OPA shows a full exemption; its legal basis is unverified","finding":"OPA currently marks the land and building assessment fully tax-exempt; BlockReport does not receive the exemption determination or basis.","why":"Full OPA exemptions can have different legal bases, including government, religious, charitable/institutional, veteran, or other treatment. The current owner/use record is not a buyer’s tax forecast.","action":"Confirm the exact exemption basis, buyer eligibility, and next tax-year treatment directly with OPA.","url":"https://www.phila.gov/departments/office-of-property-assessment/tax-exemptions-and-abatements/"},{"id":"building-certifications","level":"clear","title":"Filed system certifications are current in this dataset","finding":"Sprinkler Certification: Certified through Nov 5, 2026","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Confirm the certificate covers every applicable system and remains accepted by L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"},{"title":"Seller-specific tax relief is not the buyer’s bill","body":"LOOP and low-income or senior Real Estate Tax freezes depend on the qualifying owner and continued program eligibility; a buyer cannot assume the seller’s capped or frozen bill continues. A separately verified property abatement often remains with the property for its remaining term, but program-specific new-owner filing, use, and tax-compliance conditions still must be confirmed—not inferred from the reduced assessment alone.","action":"Have Revenue or OPA identify every current benefit, model the buyer’s bill without seller-specific relief, and confirm any verified abatement in writing.","url":"https://www.phila.gov/services/payments-assistance-taxes/payment-plans-and-assistance-programs/income-based-programs-for-residents/apply-for-the-longtime-owner-occupants-program-loop/","secondaryUrl":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/tax-freeze/"},{"title":"Seller disclosure and independent inspections","body":"For a covered Pennsylvania residential transfer, obtain the statutory seller disclosure. It reports the seller’s knowledge; it is not a warranty, title search, code review, or substitute for inspections. Because OPA dates this building before 1978, separately obtain the required federal/City lead disclosures and any test results.","action":"Have the agreement and disclosure reviewed for this transaction’s coverage and exceptions.","url":"https://www.pa.gov/agencies/dos/department-and-offices/bpoa/boards-commissions/real-estate-commission"}]}