{"asOf":"2026-07-23T15:57:56.444Z","block":"6400-6499 DITMAN ST","blockUrl":"https://philadelphia.blockreport.homes/block/6400-6499-ditman-st","address":"6401 DITMAN ST","parcelNumber":"411236405","source":"https://property.phila.gov/?p=411236405","ownerType":"owner-occupied","kind":"multi-family","isHouse":false,"home":true,"commercial":false,"residential":true,"taxExempt":false,"institutional":false,"buildingCode":"U30","buildingCodeNew":"22","buildingClass":"ROW CONV/APT 2 STY MASON","buildingClassNew":"ROW TYPICAL","useLabel":"Apartment building","owner":"CRUZ MANUEL A","coOwner":null,"marketValue":239900,"landAssessment":47980,"improvementAssessment":191920,"livableArea":1850,"yearBuilt":1935,"lastSale":{"price":65000,"date":"2010-11-23T05:00:00Z"},"openViolations":0,"violations":[{"number":"1399767","date":"2007-05-16","code":"A-503.1/2","title":"PROSEC- EMERG IMMED RI","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399770","date":"2007-05-16","code":"A-301.1/65","title":"PERM Z- NEW USE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399769","date":"2007-05-16","code":"FC-914.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399768","date":"2007-05-16","code":"FC-907.3/21","title":"AFDS-REQD EXIST MIX RES/NON-R","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399766","date":"2009-06-30","code":"PM-102.3/1","title":"LICENSE-RES SFD/2FD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"676158","date":"2007-09-11","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"676157","date":"2007-09-11","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1013698","date":"2008-07-08","code":"CP-305","title":"RUBBISH/GARBAGE EXTERIOR-OWNER","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1013697","date":"2008-07-08","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1013699","date":"2008-07-08","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1598199","date":"2010-02-23","code":"PM-302.2/2","title":"EXT A-CLEAN RUBBISH/GARBAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2349348","date":"2010-12-20","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":null,"resolutionDate":null,"resolution":null},{"number":"2349342","date":"2010-12-20","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":null,"resolutionDate":null,"resolution":null},{"number":"2349343","date":"2010-12-20","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":null,"resolutionDate":null,"resolution":null},{"number":"2349344","date":"2010-12-20","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":null,"resolutionDate":null,"resolution":null},{"number":"2349345","date":"2010-12-20","code":"A-504.1/3","title":"SWO- CONSTR W/O BLDG PERMIT","status":null,"resolutionDate":null,"resolution":null},{"number":"2349346","date":"2010-12-20","code":"A-504.1/5","title":"SWO- CONSTR W/O ELEC PERMIT","status":null,"resolutionDate":null,"resolution":null},{"number":"2349347","date":"2010-12-20","code":"A-504.1/6","title":"SWO- CONSTR W/O PLUMB PERMIT","status":null,"resolutionDate":null,"resolution":null},{"number":"2349349","date":"2010-12-20","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":null,"resolutionDate":null,"resolution":null},{"number":"2349350","date":"2010-12-20","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":null,"resolutionDate":null,"resolution":null},{"number":"2349351","date":"2012-01-20","code":"A-301.1/65","title":"PERM Z- NEW USE","status":null,"resolutionDate":null,"resolution":null},{"number":"2157256","date":"2011-07-28","code":"PM-307.1/9","title":"WALL FRACTURED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479662","date":"2012-02-06","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479661","date":"2012-02-06","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479663","date":"2012-02-06","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479664","date":"2012-02-06","code":"A-504.1/3","title":"SWO- CONSTR W/O BLDG PERMIT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479665","date":"2012-02-06","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479666","date":"2012-02-06","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479667","date":"2012-02-06","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2690327","date":"2012-07-28","code":"CP-101","title":"LICENSE - RENTAL PROPERTY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2863655","date":"2013-07-12","code":"PM-102.3/1","title":"LICENSE-RES SFD/2FD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3493876","date":"2014-08-05","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3564858","date":"2015-05-19","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3564857","date":"2015-05-19","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"113214","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2007-05-16","completedDate":"2010-11-22","violations":[{"number":"1399767","date":"2007-05-16","code":"A-503.1/2","title":"PROSEC- EMERG IMMED RI","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399770","date":"2007-05-16","code":"A-301.1/65","title":"PERM Z- NEW USE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399769","date":"2007-05-16","code":"FC-914.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399768","date":"2007-05-16","code":"FC-907.3/21","title":"AFDS-REQD EXIST MIX RES/NON-R","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1399766","date":"2009-06-30","code":"PM-102.3/1","title":"LICENSE-RES SFD/2FD","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"127671","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2007-09-11","completedDate":"2007-10-10","violations":[{"number":"676158","date":"2007-09-11","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"676157","date":"2007-09-11","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"168461","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2008-07-08","completedDate":null,"violations":[{"number":"1013698","date":"2008-07-08","code":"CP-305","title":"RUBBISH/GARBAGE EXTERIOR-OWNER","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1013697","date":"2008-07-08","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1013699","date":"2008-07-08","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"227219","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2010-02-23","completedDate":"2010-04-06","violations":[{"number":"1598199","date":"2010-02-23","code":"PM-302.2/2","title":"EXT A-CLEAN RUBBISH/GARBAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"262094","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2010-12-20","completedDate":"2012-02-01","violations":[{"number":"2349348","date":"2010-12-20","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":null,"resolutionDate":null,"resolution":null},{"number":"2349342","date":"2010-12-20","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":null,"resolutionDate":null,"resolution":null},{"number":"2349343","date":"2010-12-20","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":null,"resolutionDate":null,"resolution":null},{"number":"2349344","date":"2010-12-20","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":null,"resolutionDate":null,"resolution":null},{"number":"2349345","date":"2010-12-20","code":"A-504.1/3","title":"SWO- CONSTR W/O BLDG PERMIT","status":null,"resolutionDate":null,"resolution":null},{"number":"2349346","date":"2010-12-20","code":"A-504.1/5","title":"SWO- CONSTR W/O ELEC PERMIT","status":null,"resolutionDate":null,"resolution":null},{"number":"2349347","date":"2010-12-20","code":"A-504.1/6","title":"SWO- CONSTR W/O PLUMB PERMIT","status":null,"resolutionDate":null,"resolution":null},{"number":"2349349","date":"2010-12-20","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":null,"resolutionDate":null,"resolution":null},{"number":"2349350","date":"2010-12-20","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":null,"resolutionDate":null,"resolution":null},{"number":"2349351","date":"2012-01-20","code":"A-301.1/65","title":"PERM Z- NEW USE","status":null,"resolutionDate":null,"resolution":null}]},{"number":"288852","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2011-07-28","completedDate":"2011-09-07","violations":[{"number":"2157256","date":"2011-07-28","code":"PM-307.1/9","title":"WALL FRACTURED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"314396","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2012-02-01","completedDate":"2013-09-09","violations":[{"number":"2479662","date":"2012-02-06","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479661","date":"2012-02-06","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479663","date":"2012-02-06","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479664","date":"2012-02-06","code":"A-504.1/3","title":"SWO- CONSTR W/O BLDG PERMIT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479665","date":"2012-02-06","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479666","date":"2012-02-06","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2479667","date":"2012-02-06","code":"A-901.13/3","title":"PENALTY- NO PLUMB PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"341089","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2012-07-28","completedDate":"2015-03-13","violations":[{"number":"2690327","date":"2012-07-28","code":"CP-101","title":"LICENSE - RENTAL PROPERTY","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"391624","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2013-07-16","completedDate":"2013-07-30","violations":[{"number":"2863655","date":"2013-07-12","code":"PM-102.3/1","title":"LICENSE-RES SFD/2FD","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"446459","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2014-08-05","completedDate":"2016-07-20","violations":[{"number":"3493876","date":"2014-08-05","code":"PM-102.4/2","title":"LICENSE-VAC RES BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"481204","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2015-05-19","completedDate":"2015-06-03","violations":[{"number":"3564858","date":"2015-05-19","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3564857","date":"2015-05-19","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2007,"n":6,"worst":null},{"y":2008,"n":3,"worst":null},{"y":2009,"n":1,"worst":null},{"y":2010,"n":10,"worst":null},{"y":2011,"n":1,"worst":null},{"y":2012,"n":9,"worst":null},{"y":2013,"n":1,"worst":null},{"y":2014,"n":1,"worst":null},{"y":2015,"n":2,"worst":null}],"investigations":[{"caseNumber":"23521","date":"2004-02-23","type":"L_CLIP","status":"FAILED"},{"caseNumber":"23521","date":"2004-03-08","type":"L_CLIP","status":"CLOSED"},{"caseNumber":"71661","date":"2006-07-12","type":"BC INSP","status":"FAILED"},{"caseNumber":"71661","date":"2006-09-22","type":"BC INSP","status":"CLOSED"},{"caseNumber":"71661","date":"2006-09-22","type":"BC INSP","status":"FAILED"},{"caseNumber":"82781","date":"2006-10-03","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"82781","date":"2006-10-19","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"90798","date":"2006-11-17","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"90798","date":"2007-05-16","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"113214","date":"2007-05-16","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"127671","date":"2007-09-11","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"127671","date":"2007-10-10","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"113214","date":"2009-06-30","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"113214","date":"2009-07-21","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"113214","date":"2009-07-21","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"227219","date":"2010-02-23","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"227219","date":"2010-04-06","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"113214","date":"2010-11-22","type":"PRECOURT","status":"PASSED"},{"caseNumber":"71661","date":"2010-11-22","type":"ADMIN INSP","status":"PASSED"},{"caseNumber":"262094","date":"2010-12-20","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"262094","date":"2011-02-04","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"262094","date":"2011-06-13","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"288852","date":"2011-07-27","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"288852","date":"2011-09-07","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"262094","date":"2011-09-20","type":"BP_BLDG","status":"CLOSED"},{"caseNumber":"262094","date":"2012-01-21","type":"PRECOURT","status":"FAILED"},{"caseNumber":"262094","date":"2012-02-01","type":"PRECOURT","status":"NONE"},{"caseNumber":"262094","date":"2012-02-01","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"314396","date":"2012-03-09","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"314396","date":"2012-04-26","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"262094","date":"2012-06-20","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"314396","date":"2012-06-20","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"391624","date":"2013-07-12","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"391624","date":"2013-07-29","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"314396","date":"2013-09-04","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"446459","date":"2014-08-05","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"446459","date":"2014-10-22","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"446459","date":"2014-11-28","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"446459","date":"2015-03-12","type":"PRECOURT","status":"FAILED"},{"caseNumber":"341089","date":"2015-03-13","type":"ADMIN INSP","status":"PASSED"},{"caseNumber":"446459","date":"2015-03-26","type":"PRECOURT","status":"CLOSED"}],"inspYears":[{"y":2004,"fails":1,"passes":0},{"y":2006,"fails":4,"passes":1},{"y":2007,"fails":2,"passes":2},{"y":2009,"fails":2,"passes":0},{"y":2010,"fails":2,"passes":3},{"y":2011,"fails":2,"passes":2},{"y":2012,"fails":4,"passes":0},{"y":2013,"fails":1,"passes":2},{"y":2014,"fails":2,"passes":0},{"y":2015,"fails":1,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":40.022501778868154,"lng":-75.0524480316866,"geom":{"type":"Polygon","coordinates":[[[-75.052329583,40.022414999],[-75.0523862,40.022386393],[-75.052566277,40.022588856],[-75.052510867,40.022617667],[-75.052329583,40.022414999]]]},"liDistrict":"EAST","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19135","beds":3,"baths":1,"stories":2,"lotArea":1665,"zoning":"RSA5","grade":"C+","basement":"J","heater":"H","centralAir":false,"extCond":"4","intCond":"4","garage":null,"homestead":true,"mail":"957 E RUSSELL ST, PHILADELPHIA PA, 19134","mailOut":false,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF A SINGLE FACED FLAT WALL AWNING SIGN ACCESSORY TO A RETAIL GROCERY STORE WITH ACCESSORY RETAIL SALES OF PRE-PACKAGED FOODS & BEVERAGES (NO PREPARATION OF HOT OR COLD FOOD FOR TAKE-OUT) 1ST FLOOR IN THE SAME BUILDI","status":"CLOSED","outcome":"Denied","date":"2011-08-02","number":"14639","relatedPermit":"327851"},{"type":"Zoning board appeal","grounds":"PERMIT FOR ERECTION OF A FLAT WALL SIGN WITH A SINGLE BLANK FACE ACCESSORY TO A VACANT OFFICE SPACE AS PERMITTED IN C-2 (USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY) ON THE FIRST FLOOR AND ONE DWELLING UNIT ON THE SECOND FLOOR IN AN ATTACH","status":"CLOSED","outcome":"Granted with conditions","date":"2013-02-20","number":"18729","relatedPermit":"413012"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":3,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":195200,"taxable":195200,"land":19778,"improvement":175422,"taxableLand":19778,"taxableImprovement":175422,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":195200,"taxable":195200,"land":19778,"improvement":175422,"taxableLand":19778,"taxableImprovement":175422,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":128100,"taxable":128100,"land":26132,"improvement":101968,"taxableLand":26132,"taxableImprovement":101968,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":122200,"taxable":122200,"land":24928,"improvement":97272,"taxableLand":24928,"taxableImprovement":97272,"exemptLand":0,"exemptImprovement":0},{"y":2020,"v":127300,"taxable":127300,"land":25968,"improvement":101332,"taxableLand":25968,"taxableImprovement":101332,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":127300,"taxable":127300,"land":25968,"improvement":101332,"taxableLand":25968,"taxableImprovement":101332,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":127300,"taxable":127300,"land":25968,"improvement":101332,"taxableLand":25968,"taxableImprovement":101332,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":191800,"taxable":191800,"land":38360,"improvement":153440,"taxableLand":38360,"taxableImprovement":153440,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":191800,"taxable":191800,"land":38360,"improvement":153440,"taxableLand":38360,"taxableImprovement":153440,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":244600,"taxable":244600,"land":48920,"improvement":195680,"taxableLand":48920,"taxableImprovement":195680,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":244600,"taxable":244600,"land":48920,"improvement":195680,"taxableLand":48920,"taxableImprovement":195680,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":239900,"taxable":139900,"land":47980,"improvement":191920,"taxableLand":47980,"taxableImprovement":91920,"exemptLand":0,"exemptImprovement":100000}],"taxNow":3424,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"361430","date":"2011-09-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-09-07","scope":"REMOVE ALL LOOSE AND DAMAGED MASONRY FROM THE SECOND FLOOR REAR WALL AND REPLACE WITH NEW MASONRY TO MATCH ORIGINAL"},{"number":"362621","date":"2011-09-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 11 DUPLEX RECEPTACLES,6 SWITCHES, 3 GFCI, 6 LIGHTS FIXTURES AND 6 SMOKE DETECTORS TO AND EXISTING 100AMP PANEL AS PER 2008 NEC"},{"number":"366332","date":"2011-10-03","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"ALTERATIONS TO SECOND FLOOR APARTMENT NON LOAD BEARING PARTIONS, FLOOR, WALL, AND CEILING COVERINGS ONLY. ABSOLUTELY NO CHANGES TO FIRE RATED ASSEMBLIES. REPLACE WINDOWS IN EXISTING OPENINGS. ELECTRICAL, PLUMBING, AND MECHANICAL WORK WILL REQUIRE ADDITIONAL PERMITS.FIRE RATED ASSEMBLIES ARE REQUIRED TO BE MAINTAINED AT ALL TIMES. CALL THE INSPECTOR PRIOR TO STARTING WORK."},{"number":"366647","date":"2011-10-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-10-25","scope":"SFD-NEW KITCHEN SINK-SOME PIPING,NEW TUB,NEW BASIN-SOME PIPING."},{"number":"413012","date":"2013-05-20","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2013-05-20","scope":"FOR THE USE OF A REAL ESTATE, AUTO TAGS, INSURANCE COMPANY OR TAX PREP & ACCOUNTING OFFICE ON THE FIRST FLOOR WITH AN EXISTING DWELLING UNIT ON THE SECOND FLOOR IN AN EXISTING TWO (2) STORY ATTACHED STRUCTURE. USE PERMITTED IN ACCORDANCE WITH ZBA PROVISO CAL#18729. NO SIGNS ON THIS APPLICATION. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLAN."},{"number":"478519","date":"2013-06-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-09-09","scope":"5 FIXTURES WITH PIPING"},{"number":"481978","date":"2013-07-09","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-09-13","scope":"SAND FLOORS DRYWALL PAINT KITCHEN BATH.. ADDITIONAL PERMITS REQUIRED"},{"number":"484908","date":"2013-07-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-17","scope":"TO INSTALL 11 RECEPTACLES, 6 SWITCHES, 3 GFIC, 6 LIGHTS, AND 6 SMOKE DETECTORS PER 2008 NEC (MIXED USE)"}],"storyTag":"Improved","storyDelta":0.44,"timeline":[{"y":2012,"k":"insp","w":"Inspection failed ×4"},{"y":2013,"k":"appeal","w":"Appeal granted with conditions"},{"y":2013,"k":"permit","w":"Use"},{"y":2013,"k":"permit","w":"Plumbing"},{"y":2013,"k":"viol","w":"L&I violation"},{"y":2013,"k":"permit","w":"Alteration"},{"y":2013,"k":"permit","w":"Electrical"},{"y":2013,"k":"insp","w":"L&I: 1 failed, 2 passed"},{"y":2014,"k":"viol","w":"L&I violation"},{"y":2014,"k":"insp","w":"Inspection failed ×2"},{"y":2015,"k":"viol","w":"2 L&I violations"},{"y":2015,"k":"insp","w":"L&I: 1 failed, 1 passed"}],"rented":false,"licenses":[{"number":"404123","type":"Rental","status":"Inactive","businessName":"CARFAGNO JOSEPH          CARFAGNO LORI","legalName":"CARFAGNO JOSEPH          CARFAGNO LORI","address":"6401 DITMAN ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":2,"issuedDate":"2007-03-22","latestIssueDate":"2007-03-22","expirationDate":"2008-02-29","inactiveDate":"2012-12-22"}],"licenseActivity":[{"number":"404123","type":"Rental","businessName":"CARFAGNO JOSEPH          CARFAGNO LORI","legalName":"CARFAGNO JOSEPH          CARFAGNO LORI","issuedDate":"2007-03-22","latestIssueDate":"2007-03-22","closureDate":"2012-12-22","expirationDate":"2008-02-29","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-23","signals":[],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Appeal #18729: CLOSED · Granted with conditions; related permit 413012. Use permit #413012: COMPLETED. The history also contains “PERM Z- NEW USE.”","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"1 permit not marked completed: 366332 (EXPIRED).","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"rental-status","level":"verify","title":"Residential form does not establish rental use","finding":"OPA classifies the parcel as multi-family; no active Rental License row matched.","why":"A multi-unit or mixed-use classification does not prove that space is currently rented. If dwelling space is rented, Philadelphia generally requires a current Rental License and related occupancy, tax, violation, and lead compliance.","action":"Confirm actual occupancy first; if any unit is rented, verify the license and legal unit count with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"21 failed, 11 passed, and 8 CLOSED investigation outcomes are in the fetched history; the latest dated visit was CLOSED on Mar 26, 2015.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"verify","title":"A fire-system permit exists, but no annual certification matched","finding":"1 fire/suppression-related permit matched; the fetched BIN certification feed returned no row.","why":"Installed systems in mixed-use and larger buildings generally require periodic certification, but applicability and limited-area exceptions vary. A missing BIN/address join is not proof of a compliance failure.","action":"Confirm what system was installed and whether a current annual certificate is required and filed.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"homestead","level":"verify","title":"Homestead is tied to owner occupancy and the deed","finding":"OPA shows the Homestead Exemption.","why":"Philadelphia limits Homestead to an owner’s primary residence. The City says a deed change can require a new application or update.","action":"A buyer should apply in their own name and not assume the seller’s benefit continues.","url":"https://www.phila.gov/documents/homestead-exemption-application/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as multi-family. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 34 historical violations across 11 cases.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"},{"title":"Seller-specific tax relief is not the buyer’s bill","body":"LOOP and low-income or senior Real Estate Tax freezes depend on the qualifying owner and continued program eligibility; a buyer cannot assume the seller’s capped or frozen bill continues. A separately verified property abatement often remains with the property for its remaining term, but program-specific new-owner filing, use, and tax-compliance conditions still must be confirmed—not inferred from the reduced assessment alone.","action":"Have Revenue or OPA identify every current benefit, model the buyer’s bill without seller-specific relief, and confirm any verified abatement in writing.","url":"https://www.phila.gov/services/payments-assistance-taxes/payment-plans-and-assistance-programs/income-based-programs-for-residents/apply-for-the-longtime-owner-occupants-program-loop/","secondaryUrl":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/tax-freeze/"},{"title":"Seller disclosure and independent inspections","body":"For a covered Pennsylvania residential transfer, obtain the statutory seller disclosure. It reports the seller’s knowledge; it is not a warranty, title search, code review, or substitute for inspections. Because OPA dates this building before 1978, separately obtain the required federal/City lead disclosures and any test results.","action":"Have the agreement and disclosure reviewed for this transaction’s coverage and exceptions.","url":"https://www.pa.gov/agencies/dos/department-and-offices/bpoa/boards-commissions/real-estate-commission"}]}