{"asOf":"2026-07-23T19:03:23.840Z","block":"2300-2399 S BROAD ST","blockUrl":"https://philadelphia.blockreport.homes/block/2300-2399-s-broad-st","address":"2301 S BROAD ST","parcelNumber":"771010000","source":"https://property.phila.gov/?p=771010000","ownerType":"investor","kind":"commercial","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"YA0","buildingCodeNew":"640","buildingClass":"HEALTH FAC HOSP MASONRY","buildingClassNew":"HOSPITAL","useLabel":"Commercial","owner":"THOMAS JEFFERSON UNIVERSI","coOwner":null,"marketValue":20115900,"landAssessment":1005795,"improvementAssessment":19110105,"livableArea":542200,"yearBuilt":1975,"lastSale":{"price":8500000,"date":"1996-09-04T04:00:00Z"},"openViolations":8,"violations":[{"number":"2226239","date":"2011-09-23","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2289925","date":"2011-11-23","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2317025","date":"2011-12-22","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2335556","date":"2012-01-17","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"2364236","date":"2012-02-16","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2434339","date":"2012-05-07","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2500408","date":"2012-07-10","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2593985","date":"2012-09-28","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3025671","date":"2013-12-03","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3025670","date":"2013-12-04","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3444754","date":"2014-07-03","code":"A-301.1/64","title":"PERMZ- CONST REMOV CHANGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3444753","date":"2014-07-03","code":"A-301.1/1","title":"PERMB- CONST ERECT NEW STRUCT","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3868981","date":"2016-03-14","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2023-077686","date":"2023-10-05","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"CLOSED","resolutionDate":"2025-03-03","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2023-077687","date":"2023-10-05","code":"F-901.6.4.2","title":"SUBMISSION OF CERTIFICATIONS\n","status":"CLOSED","resolutionDate":"2025-03-03","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2023-077688","date":"2023-10-05","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"CLOSED","resolutionDate":"2025-03-03","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2025-010744","date":"2025-03-03","code":"F-701.6.1.5","title":"DAMPER CERTIFICATION REPORT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-010743","date":"2025-03-03","code":"F-904.12","title":"COMMERCIAL COOKING SYSTEMS\n","status":"COMPLIED","resolutionDate":"2025-06-05","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2025-010741","date":"2025-03-03","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2025-06-05","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2025-010742","date":"2025-03-03","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-05-06","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2026-031954","date":"2026-05-14","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-031955","date":"2026-05-14","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-031956","date":"2026-05-14","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-031957","date":"2026-05-14","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-034711","date":"2026-05-20","code":"F-604.1","title":"ABATEMENT OF ELECTRICAL HAZARDS\n","status":"COMPLIED","resolutionDate":"2026-06-23","resolution":"COMPLIED - OWNER REPAIR"}],"violationCases":[{"number":"299094","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-09-26","completedDate":"2011-09-26","violations":[{"number":"2226239","date":"2011-09-23","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"307344","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-11-28","completedDate":"2011-11-28","violations":[{"number":"2289925","date":"2011-11-23","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"310532","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-12-23","completedDate":"2011-12-23","violations":[{"number":"2317025","date":"2011-12-22","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"312702","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-01-18","completedDate":"2012-01-18","violations":[{"number":"2335556","date":"2012-01-17","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"316565","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-02-17","completedDate":"2012-02-17","violations":[{"number":"2364236","date":"2012-02-16","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"327042","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-05-08","completedDate":"2012-05-08","violations":[{"number":"2434339","date":"2012-05-07","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"338044","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-07-11","completedDate":"2012-07-11","violations":[{"number":"2500408","date":"2012-07-10","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"353093","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-10-01","completedDate":"2012-10-01","violations":[{"number":"2593985","date":"2012-09-28","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"412953","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-12-04","completedDate":"2013-12-04","violations":[{"number":"3025671","date":"2013-12-03","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3025670","date":"2013-12-04","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"441127","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DS","status":"CLOSED","createdDate":"2014-07-08","completedDate":null,"violations":[{"number":"3444754","date":"2014-07-03","code":"A-301.1/64","title":"PERMZ- CONST REMOV CHANGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3444753","date":"2014-07-03","code":"A-301.1/1","title":"PERMB- CONST ERECT NEW STRUCT","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"523849","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-03-15","completedDate":"2016-04-25","violations":[{"number":"3868981","date":"2016-03-14","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2023-104450","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2023-10-05","completedDate":"2025-03-03","violations":[{"number":"VI-2023-077686","date":"2023-10-05","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"CLOSED","resolutionDate":"2025-03-03","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2023-077687","date":"2023-10-05","code":"F-901.6.4.2","title":"SUBMISSION OF CERTIFICATIONS\n","status":"CLOSED","resolutionDate":"2025-03-03","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2023-077688","date":"2023-10-05","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"CLOSED","resolutionDate":"2025-03-03","resolution":"CLOSED - REISSUED/REWRITTEN"}]},{"number":"CF-2025-013628","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QUALITY OF LIFE COURTS","status":"IN VIOLATION","createdDate":"2025-03-03","completedDate":null,"violations":[{"number":"VI-2025-010744","date":"2025-03-03","code":"F-701.6.1.5","title":"DAMPER CERTIFICATION REPORT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-010743","date":"2025-03-03","code":"F-904.12","title":"COMMERCIAL COOKING SYSTEMS\n","status":"COMPLIED","resolutionDate":"2025-06-05","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2025-010741","date":"2025-03-03","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2025-06-05","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2025-010742","date":"2025-03-03","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-05-06","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2026-051165","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2026-05-12","completedDate":null,"violations":[{"number":"VI-2026-031954","date":"2026-05-14","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-031955","date":"2026-05-14","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-031956","date":"2026-05-14","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-031957","date":"2026-05-14","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"CF-2026-056741","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2026-05-21","completedDate":"2026-06-23","violations":[{"number":"VI-2026-034711","date":"2026-05-20","code":"F-604.1","title":"ABATEMENT OF ELECTRICAL HAZARDS\n","status":"COMPLIED","resolutionDate":"2026-06-23","resolution":"COMPLIED - OWNER REPAIR"}]}],"violYears":[{"y":2011,"n":3,"worst":null},{"y":2012,"n":5,"worst":null},{"y":2013,"n":2,"worst":null},{"y":2014,"n":2,"worst":null},{"y":2016,"n":1,"worst":null},{"y":2023,"n":3,"worst":null},{"y":2025,"n":4,"worst":null},{"y":2026,"n":5,"worst":null}],"investigations":[{"caseNumber":"82410","date":"2006-09-29","type":"CI INSP","status":"FAILED"},{"caseNumber":"82410","date":"2006-09-29","type":"CI INSP","status":"PASSED"},{"caseNumber":"299094","date":"2011-09-23","type":"CI INSP","status":"PASSED"},{"caseNumber":"307344","date":"2011-11-23","type":"CI INSP","status":"PASSED"},{"caseNumber":"310532","date":"2011-12-22","type":"CI INSP","status":"PASSED"},{"caseNumber":"312702","date":"2012-01-17","type":"CI INSP","status":"PASSED"},{"caseNumber":"316565","date":"2012-02-16","type":"CI INSP","status":"PASSED"},{"caseNumber":"327042","date":"2012-05-07","type":"CI INSP","status":"PASSED"},{"caseNumber":"338044","date":"2012-07-10","type":"CI INSP","status":"PASSED"},{"caseNumber":"353093","date":"2012-09-28","type":"CI INSP","status":"PASSED"},{"caseNumber":"412953","date":"2013-12-03","type":"CI INSP","status":"PASSED"},{"caseNumber":"441127","date":"2014-07-03","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"441127","date":"2014-08-15","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"441127","date":"2014-09-22","type":"BP_BLDG","status":"CLOSED"},{"caseNumber":"441127","date":"2015-01-13","type":"PRECOURT","status":"FAILED"},{"caseNumber":"523849","date":"2016-03-14","type":"CI INSP","status":"FAILED"},{"caseNumber":"523849","date":"2016-04-22","type":"CI INSP","status":"PASSED"},{"caseNumber":"CF-2023-104450","date":"2023-10-05","type":null,"status":"FAILED"},{"caseNumber":"CF-2023-104450","date":"2025-03-03","type":null,"status":"PASSED"},{"caseNumber":"CF-2025-013628","date":"2025-03-03","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-013628","date":"2025-05-06","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-013628","date":"2025-10-30","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-051165","date":"2026-05-14","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-056741","date":"2026-05-21","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-056741","date":"2026-06-23","type":null,"status":"PASSED"},{"caseNumber":"CF-2026-051165","date":"2026-06-23","type":null,"status":"FAILED"}],"inspYears":[{"y":2006,"fails":1,"passes":1},{"y":2011,"fails":0,"passes":3},{"y":2012,"fails":0,"passes":5},{"y":2013,"fails":0,"passes":1},{"y":2014,"fails":2,"passes":0},{"y":2015,"fails":1,"passes":0},{"y":2016,"fails":1,"passes":1},{"y":2023,"fails":1,"passes":0},{"y":2025,"fails":3,"passes":1},{"y":2026,"fails":3,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.92112642243821,"lng":-75.16925894223482,"geom":{"type":"Polygon","coordinates":[[[-75.170046392,39.921768246],[-75.168236542,39.921552287],[-75.168476561,39.920469264],[-75.1702892,39.920718587],[-75.170046392,39.921768246]]]},"liDistrict":"SOUTH","certifications":[{"number":"BC-2022-003729","type":"Facade Report","inspectionDate":"2015-09-01","result":"Safe with Repair","expirationDate":"2020-09-01","buildingId":"1410690"},{"number":"BC-2022-003491","type":"Facade Report","inspectionDate":"2016-12-01","result":"Safe with Repair","expirationDate":"2021-12-01","buildingId":"1429501"},{"number":"BC-2021-001781","type":"Facade Report","inspectionDate":"2021-06-18","result":"Safe with Repair","expirationDate":"2026-03-01","buildingId":"1429501"},{"number":"BC-2021-002640","type":"Sprinkler Certification","inspectionDate":"2021-07-26","result":"Certified","expirationDate":"2022-07-26","buildingId":"1410690"},{"number":"BC-2022-014343","type":"Sprinkler Certification","inspectionDate":"2022-07-22","result":"Certified","expirationDate":"2023-07-22","buildingId":"1429501"},{"number":"BC-2024-002277","type":"Fire Alarm Certification","inspectionDate":"2023-02-01","result":"Certified","expirationDate":"2024-02-01","buildingId":"1429501"},{"number":"BC-2023-023434","type":"Special Hazards Certification","inspectionDate":"2023-04-19","result":"Certified","expirationDate":"2024-04-19","buildingId":"1429501"},{"number":"BC-2023-018579","type":"Sprinkler Certification","inspectionDate":"2023-07-21","result":"Deficient","expirationDate":null,"buildingId":"1429501"},{"number":"BC-2023-016262","type":"Sprinkler Certification","inspectionDate":"2023-07-21","result":"Certified","expirationDate":"2024-07-21","buildingId":"1429501"},{"number":"BC-2023-023217","type":"Damper Certification","inspectionDate":"2023-10-20","result":"Certified","expirationDate":"2024-10-20","buildingId":"1429501"},{"number":"BC-2023-022555","type":"Sprinkler Certification","inspectionDate":"2023-10-27","result":"Certified","expirationDate":"2024-10-27","buildingId":"1429501"},{"number":"BC-2023-024971","type":"Fire Alarm Certification","inspectionDate":"2023-11-01","result":"Certified","expirationDate":"2024-11-01","buildingId":"1429501"},{"number":"BC-2025-008999","type":"Sprinkler Certification","inspectionDate":"2024-07-25","result":"Certified","expirationDate":"2025-07-25","buildingId":"1429501"},{"number":"BC-2025-008973","type":"Sprinkler Certification","inspectionDate":"2024-07-31","result":"Certified","expirationDate":"2025-07-31","buildingId":"1429501"},{"number":"BC-2025-014146","type":"Fire Alarm Certification","inspectionDate":"2025-04-25","result":"Certified","expirationDate":"2026-04-25","buildingId":"1429501"},{"number":"BC-2025-015027","type":"Special Hazards Certification","inspectionDate":"2025-05-08","result":"Certified","expirationDate":"2026-05-08","buildingId":"1429501"},{"number":"BC-2026-001384","type":"Damper Certification","inspectionDate":"2026-01-14","result":"Certified","expirationDate":"2027-01-14","buildingId":"1429501"},{"number":"BC-2026-005264","type":"Facade Report","inspectionDate":"2026-02-23","result":"Safe with Repair","expirationDate":"2031-02-23","buildingId":"1429501"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19148","beds":null,"baths":null,"stories":null,"lotArea":206556,"zoning":"CMX3","grade":"A","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"111 S 11TH ST, PHILADELPHIA PA, 19107","mailOut":false,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT IS FOR THE ERECTION OF A ONE STORY ADDITION AT GROUND LEVEL WITH TWO (2) ROOFTOP, AIR HANDLING UNITS) TO AN EXISTING HOSPITAL COMPLEX, FOR THE ERECTION OF A ONE STORY ADDITION WITH ONE (1) ROOFTOP AIR HANDLING UNIT) AT THE 3RD STORY ","status":"CLOSED","outcome":"Granted with conditions","date":"2007-07-18","number":"2061","relatedPermit":null},{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF A ONE STORY ADDITION AND A TWO STORY ADDITION ATOP AN EXISTING ONE STORY STRUCTURE MAXIMUM HEIGHT OF 43'-11\" ( WOLF STREET SIDE ) FOR THE EXTENSION OF A HOSPITAL COMPLEX TO INCLUDE AN 800 SQ. FT. LOBBY AT THE FIRS","status":"CLOSED","outcome":"Granted with conditions","date":"2010-05-05","number":"11481","relatedPermit":"271462"},{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF A ONE (1) STORY DETACHED TEMPORARY TRAILER (8'6\" X 52'0\")  WITH  TWO SIDE CHAIN LINK FENCE SIX FT HIGH AND REMOVAL OF  SEVEN OPEN AIR OFF STREET PARKING SPACE FOR ERECTION OF MRI  TEMPORARY TRAILER FOR THE EXTENSI","status":"CLOSED","outcome":"Granted","date":"2011-05-03","number":"14951","relatedPermit":"334335"},{"type":"Zoning board appeal","grounds":"PERMIT FOR THE REMOVAL AND REPLACEMENT OF AN EXISTING ILLUMINATED FLAT WALL SIGN (SIGN \"A\"; SMALLER THAN ORIGINAL), THE LEGALIZATION AND REFACING OF ONE (1) DOUBLE-FACED, INTERNALLY ILLUMINATED PROJECTING SIGNS (SIGN \"B\") AND ONE (1) INTERN","status":"CLOSED","outcome":"Granted with conditions","date":"2014-02-26","number":"21964","relatedPermit":"498106"},{"type":"ZBA Permit Denial - Variance","grounds":"PERMIT FOR THE REMOVAL OF ONE (1) DOUBLE FACED FREE-STANDING SIGN (SIGN 2), ONE (1) FLAT WALL SIGN (SIGN 53), TO REPLACE FREE-STANDING SIGN (SIGN 22) WITH SINGLE FACED NON-ILLUMINATED FREE-STANDING SIGN (SIGN 104), FOR THE INSTALLATION OF T","status":"Completed","outcome":"Granted with conditions","date":"2021-03-25","number":"ZP-2020-004274","relatedPermit":"ZP-2020-004274"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":true,"assessmentExemption":true,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":18869700,"taxable":3001824,"land":628700,"improvement":18241000,"taxableLand":51436,"taxableImprovement":2950388,"exemptLand":577264,"exemptImprovement":15290612},{"y":2017,"v":18869700,"taxable":3001824,"land":628700,"improvement":18241000,"taxableLand":51436,"taxableImprovement":2950388,"exemptLand":577264,"exemptImprovement":15290612},{"y":2018,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2019,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2020,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2021,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2022,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2023,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2024,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2025,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2026,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144},{"y":2027,"v":20115900,"taxable":3173248,"land":1005795,"improvement":19110105,"taxableLand":82287,"taxableImprovement":3090961,"exemptLand":923508,"exemptImprovement":16019144}],"taxNow":44419,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"49985","date":"2007-01-15","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-11-09","scope":null},{"number":"48097","date":"2007-01-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-25","scope":"DEMO EXISTING, NEW LIGHTS, SWITCHES, RECEPTS AND PANELS, NEW FIRE ALARM DEVICES TIED INTO EXISTING SYSTEM ON 3RD FLOOR"},{"number":"56234","date":"2007-03-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-19","scope":"DUCTWORK ALTERATIONS IN EXISTING PORTION OF THE BUILDING. THE DUCTWORK IN THE PROPOSED ADDITION (HISTOLOGY) IS NOT INCLUDED IN THIS PERMIT NOR ARE THE NEW ROOFTOP UNITS (ZONING APPROVAL RQUIRED FOR THESE)."},{"number":"48885","date":"2007-03-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-11-09","scope":"INTERIOR ALTERATIONS ONLY FOR NEW CLINICAL LABORATORY ON 1ST FLOOR."},{"number":"63308","date":"2007-03-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLING 2 WATER CLOSETS, 2 LAV'S, 20 KITCHEN SINKS, 2 FLOOR DRAINS, AND INDIRECT WASTE"},{"number":"80021","date":"2007-06-08","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-12-28","scope":"CONVERT (6) DRY TO AUTO WET STANDPIPE IN HOSPITAL"},{"number":"86568","date":"2007-07-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-03-03","scope":"INTERIOR RENOVATIONS, UPGRADES, FINISHES AS PER PLANS"},{"number":"88877","date":"2007-07-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-11-25","scope":"WE ARE INSTALLING NEW 2 WC, 3 LAVS, 3 STAINLESS STEEL SINKS ON THE 2ND FL OF RADIOLOGY. WE WILL BE MAKING SANITARY AND WATER TIE-INS FOR THE VARIOUS FIXTURES AND INSTALLING NEW PIPING FOR EACH FIXTURE."},{"number":"68462","date":"2007-07-20","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2007-07-20","scope":"CONSTRUCT (1) STORY ADDITION TO EXISTING BLDG. ON GRADE AND CONSTRUCT (1) STORY ADDITION TO EXISTING (2) STORY BLDG. WITH ROOFTOP AIR HANDLING UNITS, AS SHOWN ON ATTACHED PLAN."},{"number":"87011","date":"2007-08-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-11-19","scope":"RENOVATIONS (930 SQ. FT.) PER SUBMITTED SEALED PLANS. ADD'L ELEC., PLUMB, D/W, SPRINKLER PERMITS."},{"number":"95257","date":"2007-08-15","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2007-11-19","scope":"NEW ONE-STORY ADDITION ONLY (730 SQ. FT.) PER SUBMITTED SEALED PLANS. ADD'L ELEC., PLUMB, D/W, SPRINKLER PERMITS. C.O."},{"number":"92420","date":"2007-08-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-22","scope":"HVAC INSTALLATION AS PER PLAN."},{"number":"101294","date":"2007-09-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-04-25","scope":"RELOCATE 76 SPRINKLER HEADS (2ND FLOOR - RADIOLOGY)"},{"number":"1458","date":"2007-09-10","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2007-09-10","scope":"9/14/07 - TENT ERECTED - PARKING LOT AREA"},{"number":"1512","date":"2007-09-27","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2007-09-27","scope":"9/28/07 - TENTS ERECTED @ NOVA CARE COMPLEX"},{"number":"99736","date":"2007-10-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-03-11","scope":"HVAC INCLUDING DUCTWORK"},{"number":"110249","date":"2007-11-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-03-22","scope":"REPLACE EXISTING 4 GENERATORS WITH 2 NEW GRENERATORS, 1 SWITCH BOARD WITH NEW FEEDERS (SOUTH DIST)"},{"number":"117192","date":"2007-11-30","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2007-11-30","scope":"FOR THE ERECTION OF TWO (2) EMERGENCY GENERATORS AT GRADE,AND FOR INSERTION OF AN UNDERGROUND FUEL TANK WITH RELATED FUEL PUMP. SIZE AND LOCATION AS SHOWN IN THE APPLICATION. EMRGENCY GENERATORS AND FUEL TANK ACCESSORY TO AN EXISTING HOSPITAL COMPLEX."},{"number":"120984","date":"2008-01-30","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2008-04-25","scope":"INSTALL 1- 10,000 GALLON DOUBLE WALL FIBERGLASS TANK BELOW GRADE AS PER PLANS. ALL WORK TO BE IN ACCORDANCE WITH PA. DEP REGULATIONS, ALL APPLICABLE CODES, NFPA 30, AND NFPA 31."},{"number":"139201","date":"2008-03-18","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-04-30","scope":"INTERIOR DEMOLITION OF NON LOAD BEARING PARTITIONS THROUGH OUT THE SECOND FLOOR A THE HOSPITAL. APPLICANT AGREES TO LIMIT CONSTRUCTION TO COMPLY WITH EZ PERMIT STANDARD DATED FEBRUARY, 2007. DEVIATION FROM THIS STANDARD WILL RESULT IN THE REVOCATION OF THIS PERMIT AND THE IMPOSITION OF FURTHER PENALTIES."},{"number":"141162","date":"2008-03-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"DEMO EXISTING LT FIXTURES, DEVICES AND BRANCH CRTS, 2 SUB PANELS BACK TO SOURSE. INSTALL 50 TEMP 100W LIGHT BULBS, NO WORK WILL BE DONE ON BUILDINGS MAIN ELEC SERVICE, FUTURE CONNECTION OF ELEC EQUIP WILL BE UNDER SEP PERMIT FOR 6 MONTHS(SOUTH DIST)"},{"number":"153721","date":"2008-05-21","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-09-02","scope":"INTERIOR NON-LOAD BEARING DEMOLITION - 1ST FLOOR LOBBY METHODIST HOSPITAL"},{"number":"141248","date":"2008-06-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-10-15","scope":"INTERIOR RENOVATIONS"},{"number":"155241","date":"2008-06-13","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2008-06-13","scope":"ERECTION OF A MECHANICL TOWER (AIR HANDLING UNIT) ON ROOF OF AN EXISTING 3RD STORY PORTION OF AN EXISTING STRUCTURE. FOR USE OF THE EXISTING HOSPITAL."},{"number":"159353","date":"2008-06-19","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-03-20","scope":null},{"number":"154906","date":"2008-06-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-10-09","scope":"INSTALL LIGHTING RELAY PANEL, 20 LIGHT FIXTURES, 2 RECEPTACLES, RELOCATE DEVICES TO NEW WALLS & CONNECT UNIT HEATER."},{"number":"163186","date":"2008-07-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-10-15","scope":"INSTALL DUCTWORK AND RELATED MECHANICALS"},{"number":"156316","date":"2008-08-01","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-10-15","scope":"INTERIOR RENOVATIONS AS PER PLANS."},{"number":"165366","date":"2008-08-05","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-08-25","scope":"INSTALL FIXTURES"},{"number":"168560","date":"2008-08-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-10-15","scope":"INSTALL AUTOMATIC SPRINKLER SYSTEM."},{"number":"165016","date":"2008-08-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-09-11","scope":"INSTALL 13 NEW DUPLEX RECEPTS NAD 2 GFI RECEPTS, INSTALL 9 - 2X4 FIXTURES AND 2 UNDERCABINET FIXTURES, 7 OCCUPANCY SENSORS AND 3 SINGLE POLE SWITCHES, ALL CIRCUITS FROM EXISTING PANEL BOARD, RELOCATE FIRE ALARM STROBE TO NEW CEILING AS PER 2005 NEC (SOUTH DISTRICT)"},{"number":"170296","date":"2008-08-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-03-20","scope":"INSTALL AUTOMATIC SPRINKLERS."},{"number":"168815","date":"2008-09-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-10-29","scope":"INSTALL 18 NEW STROBES, HORN/STROBES AND 2 PULL STATIONS AS PER 2005 NEC (SOUTH DISTRICT)"},{"number":"12586","date":"2008-09-15","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2008-09-15","scope":"9/19/08 - TENTS ERECTED ON SITE"},{"number":"178356","date":"2008-09-22","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-12-19","scope":null},{"number":"161213","date":"2008-09-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-10-29","scope":"INSTALL ABOUT 100 LIGHTS, 4 NEW PANELS, 1 NEW LIGHTING CONTROL PANEL, NEW NURSES CALL SYSTEM, 150 RECEPTS AS PER 2005 NEC (SOUTH DISTRICT)"},{"number":"186464","date":"2008-11-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-03-12","scope":"RENOVATION OF EXISTING RADIOLOGY ROOM IN ASSOCIATED WAITING ROOM. FOR HOSPITAL."},{"number":"186461","date":"2008-11-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-03-12","scope":"INTERIOR RENOVATIONS OF EXISTING WOMEN'S DIAGNOSTIC AREA AS PER SUBMITTED PLANS."},{"number":"173806","date":"2008-12-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-16","scope":"INSTALL (2) LIGHTING CONTROL PANELS, INSTALL OUTSIDE FACADE LIGHT FIXTURES, (5) ON ROOF, (2) FLAGPOLE UP LIGHTS, (21) GROUND LEVEL UP LIGHTS AND (12) MOUNTED ON BUILDING FACADE AS PER 2005 NEC(SOUTH DIST)"},{"number":"193516","date":"2008-12-18","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-03-20","scope":null},{"number":"188473","date":"2008-12-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-03-12","scope":"HVAC RENOVATION"},{"number":"190264","date":"2008-12-31","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-01-28","scope":"INSTALL 6 AUTO SPRINKLERS ON THE 2ND FLOOR NUCLEAR CAMERA ROOM"},{"number":"192262","date":"2009-01-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-07-14","scope":"9 NEW 2X4 FIXTURES AND 3 OCCUPANCY SENSORS, FEED NEW EQUIPMENT FROM EXISTING PANELS, ADD NEW RECEPTS, PULL GE LOW VOLTAGE SYSTEMS CABLE 20/3 FEED TO AIR HANDLER AND 30/3 FEED TO OUTSIDE CONDENSER AS PER 2005 NEC (SOUTH DISTRICT)"},{"number":"195402","date":"2009-01-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-01-28","scope":"INSTALL NEW SINK/CONNECT TO EXISTING WATER AND DRAIN"},{"number":"195731","date":"2009-01-07","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-03-20","scope":null},{"number":"195391","date":"2009-01-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-03-12","scope":"HVAC RENOVATION FOR HOSPITAL"},{"number":"203749","date":"2009-03-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-09-11","scope":"ADD SMOKE DETECTORS, HORN/STROBES NAD STROBE TO EXISTING FACP AS PER NFPA72 (SOUTH DISTRICT)"},{"number":"223453","date":"2009-06-25","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-06-02","scope":"RENDER TANK INERT PER PLAN 1500 GAL OIL TANK"},{"number":"226489","date":"2009-08-03","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2010-08-26","scope":"CONSTRUCT/INFILL FOR 3RD STORY ADDITION ATOP EXISTING 2 STORY BUILDING, ASSOCIATED INTERIOR/EXTERIOR ALTERATIONS FOR OPENINGS, FIT OUT OF EXISTING HOSPITAL, AS PER SUBMITTED PLANS"},{"number":"231169","date":"2009-08-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-03-05","scope":"FIXTURE INSTALLATION"},{"number":"231175","date":"2009-09-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-03-31","scope":"ALTERATIONS TO MECHANICAL SYSTEM TO INCLUDE DEMOLITION AND UPGRADES TO A/C SYSTEM, MECHANICAL UNITS AND DUCTWORK."},{"number":"245433","date":"2009-10-29","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"EXPIRED","completedDate":null,"scope":null},{"number":"249190","date":"2009-11-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-02-09","scope":"INSTALLATION OF NEW WASTE , VENT AND HOT & COLD WATER, ALL NEW PIPING WILL CONNECTION TO EXISTING MAINS, 1 WATER CLOSET, 1 LAVY, 3 SINKS, 1 CLINIC SINK"},{"number":"250255","date":"2009-12-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-08-18","scope":"INTERIOR ALTERATIONS AS PER PLANS."},{"number":"252884","date":"2010-01-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-08-20","scope":"INSTALL NEW SPRINKLER SYSTEM PROTECTION FOR 3RD FLOOR OPERATING ROOM, CONNECT TO EXISTING SYSTEM AS PER PLAN AND CALCS."},{"number":"234687","date":"2010-01-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-09","scope":"NEW ELECTRICAL SERVICES, INCLUDING LIGHTING POWER AS PER 2005 NEC (SOUTH DISTRICT)INSTALL FIRE ALARM AS PER NFPA"},{"number":"248808","date":"2010-01-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-09","scope":"NEW ELECTRICAL SERVICES, INCLUDING LIGHTING POWER, NURSE CALL AND WIRING DEVICES AS PER 2005 NEC (SOUTH DISTRICT)"},{"number":"254422","date":"2010-01-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-04-20","scope":"INSTALLATION OF DUCTWORK"},{"number":"259043","date":"2010-02-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-01-20","scope":"FURNISH & INSTALL NEW 2ND FLOOR SHELL SPACE AND 3RD FLOOR FOR INFUSION UNIT RELOCATION AS PER 2005 NEC. FIRE PUMP INSTALLATION TO COMPLY WITH ARTICLE 695.4(B)(1) OF THE 2005 NEC. (SOUTH DISTRICT)"},{"number":"262655","date":"2010-03-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-18","scope":"ADDITION OF LNEW DEVICES ADDED 2ND & 3RD FLOORS AND ELEVATOR RECALL ALSO REPLACE SOME EXISTING DEVICES ON 1ST FLOOR AS PER NFPA 72 (SOUTH DISTRICT)"},{"number":"271462","date":"2010-05-07","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2010-05-07","scope":"FOR THE ERECTION OF A ONE (1) STORY ADDITION TO AN EXISTING STRUCTURE AND A TWO (2) STORY ADDITION ATOP AN EXISTING (1) ONE STORY STRUCTURE, SIZE AND LOCATION AS SHOWN IN APPLICATION. FOR A \"LOBBY\" AT THE FIRST FLOOR LEVEL AND MEDICAL OFFICES WITHIN THE TWO STORY ADDITION BOTH ACCESSORY TO AN EXISTING HOSPITAL COMPLEX, NO SIGNS ON THIS APPLICATION."},{"number":"259851","date":"2010-05-28","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2011-05-23","scope":"2 STORY VERTICAL ADDITION TO 1 STORY EXISTING AS PER PLANS. NO UNDERPINNING IS APPROVED. IF UNDERPINNING IS REQUIRED, A NEW BUILDING PERMIT SHALL BE SUBMITTED FOR APPROVAL."},{"number":"282446","date":"2010-06-01","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-12-14","scope":"INTERIOR DEMOLITION OF NON BEARING APRTITIONS"},{"number":"285931","date":"2010-06-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-22","scope":"RELOCATE 48 DIFFUSERS. NO RECONFIGURATION OF EXISTING DUCTWORK, OR HVAC SYSTEM ALLOWED UNDER THIS PERMIT"},{"number":"282866","date":"2010-06-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-09-13","scope":"\"RENOVATION TO PATIENT UNIT ON THE 4TH FL INCLUDING NEW FINISHES\" PERMIT TO INCLUDE INTERIOR DEMOLITION AND THE CONSTRUCTION OF NEW PARTITIONS, SOFFITS,CEILINGS, AND FINISHES TO RECONFIGURE THE EXISTING 4TH FLOOR I USE SPACE.SEPARATE PERMITS REQUIRED FOR PLUMBING, ELECTRICAL, MECHANICAL, AND FIRE SUPPRESSION WORK."},{"number":"286463","date":"2010-06-25","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-09-13","scope":"RELOCATE SPRINKLER HEADS"},{"number":"283079","date":"2010-06-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-09-15","scope":"NEW CORRIDOR LIGHTS, NEW RECEPTACLES, NO FIRE ALARM EXISTING AS PER 2008 NEC"},{"number":"284996","date":"2010-07-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-08-31","scope":"22 FIXTURES WITH PIPING AS PER PLANS"},{"number":"283817","date":"2010-07-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-12","scope":"HVAC DUCTWORK AND NEW DIFFUSERS/REGISTERS THROUGHOUT MEDICAL OFFICE BUILDING AS PER PLANS."},{"number":"283694","date":"2010-07-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-12-14","scope":"INSTALL (7) WATER CLOSETS, (19) LAV'S, (3) SINKS, (2) MOP RECEPTACLES, (1) OPEN SITE DRAIN FOR ICE MAKER, (3) ROOF DRAINS"},{"number":"290223","date":"2010-08-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"1 AV BOOSTER PANEL, 9 STROBES, 2 AV, 1 PULL STATION, 1 SMOKE DAMPER, 1 SMOKE DETECTOR AS PER NFPA 72"},{"number":"292409","date":"2010-08-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-12-27","scope":"CONNECT INTO EXISTING 4\" SPRINKLER MAIN & FURNISH AND INSTALL ONE NEW 400 GPM ELECTRIC FIRE PUMP & NEW SPRINKLER PROTECTION FOR THE 3RD FL ADDITION. 2ND FL ADDITION TO HAVE THE CROSS MAIN & PLUGS FOR FUTURE FIT-OUT. 1ST FL TO HAVE 6 HEADS INSTALLED IN NE ELEVATOR LOBBY AS PER PLANS."},{"number":"300820","date":"2010-10-06","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2012-01-05","scope":"AMENDMENT TO PERMIT AP# 259851 TO REFLECT NEW CHANGES AS PER PLANS."},{"number":"305498","date":"2010-10-08","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-12-14","scope":"1 MOP RECEPTACLE, 1 WATER CLOSET, 3 SINKS"},{"number":"295891","date":"2010-10-08","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2012-01-12","scope":"AMEND PERMIT# 283817 TO REFLECT THE RECONFIGURATION OF PORTION OF THE EXISTING HVAC DUCTWORK LAYOUT AND ADDITION OF NEW DUCTWORK AS PER PLANS."},{"number":"302841","date":"2010-10-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-18","scope":"NEW LIGHTING,SWITCHES, RECEPTACLES AND 3 PANELS PER PLANS,PER 2008 NEC"},{"number":"304111","date":"2010-10-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-07-18","scope":"FURNISH AND INSTALL NEW CHILLER ON EXISTING ROOF TO UPGRADE THE HVAC FOR HOSPITAL. SEPARTED PERMIT REQUIRED IF THE ROOFTOP UNIT IS 6'X6'X6' OR LARGES."},{"number":"305500","date":"2010-11-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-12-14","scope":"INSTALL 21 WC'S,19 LAV'S,6 SINKS,14 SHOWERS,16 FLOOR DRAINS,1 WASHER BOX, 1 OPEN SITE DRAIN/ICE MAKER,1 MOP RECEPTACLE"},{"number":"308790","date":"2010-11-08","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-05-09","scope":"INTERIOR DEMO OF NON LOAD-BEARING PARTITIONS AT FORMER CLINICAL PHARMACOLOGY UNIT."},{"number":"306005","date":"2010-11-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-01-19","scope":"FOR THE INSTALLATION OF HVAC SYSTEM TO INCLUDE DUCTS, DIFFUSERS, DAMPERS AND ROOFTOP MECHANICAL EQUIPMENT AS PER PLANS ACCESSORY TO AN EXISTING HOSPITAL COMPLEX."},{"number":"306447","date":"2010-12-01","work":"Zoning admin review","type":"ZP_ADMIN","description":"ZONING ADMIN REVIEW","status":"COMPLETED","completedDate":"2010-12-22","scope":"FOR A NEW (800) SQ. FT. LOBBY AT THE FIRST FLOOR OF EXISTING BUILDING (1300 WOLF ST.) AND A TWO STORY ADDITION TO THE EXISTING STRUCTURE (1300 WOLF ST) FOR INPATIENT HOSPICE UNIT 2ND FLOOR AND MEDICAL OFFICES INCLUDING OUTPATIENT INFUSION CENTER 3RD FLOOR, NO SIGNS ON THIS APPLICATION."},{"number":"301442","date":"2010-12-03","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2011-06-14","scope":"FIT OUT OF 2ND FLOOR SHELL SPACE CONSTRUCTED UNDER PERMIT #259851 TO CREATE A MEDICAL UNIT OPERATED BY VITAS. WORK INCLUDES DRYWALL PARTITIONS, ACCOUSTICAL CEILING MILLWORK, DOORS, FRAMES, HARDWARE, FINISHES, HVAC AND SPRINKLER FOR HOSPICE CARE UNIT."},{"number":"20853","date":"2010-12-07","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2010-12-07","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 12/15/11."},{"number":"313630","date":"2010-12-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-03-17","scope":"INSTALL 210 CAT6 PLENUM CABLES FOR VOICE AND DATA APPLICATIOS,INSTALL CLIENT PROVIDED COMMUNICATION CABENTS AND COMMUNICATION EQUIPMENT AS PER 2008 NEC"},{"number":"306871","date":"2010-12-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 60A 480V & HEAT TRACE FOR CHILLER. INSTALL HEAT TRACE FOR HEAT RECOVERY UNITS."},{"number":"315879","date":"2010-12-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL SMOKE DETECTORS,AV DEVICES PULL STATION AND SMOKE FIRE DAMPER CONTROL AS SHOWN ON PLANS,AS PER 2008 NEC,NFPA 72"},{"number":"321732","date":"2011-01-20","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2011-01-28","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY"},{"number":"321810","date":"2011-01-24","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-04-28","scope":"INTERIOR ALTERATIONS: SINK AND FLOOR DRAIN"},{"number":"320767","date":"2011-02-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"DEMO EXISTING LAB AND INSTALL NEW CVIRLAB WITH NEW LIGHTING,OUTLETS AND NORMAL AND EMERGENCY FEEDERS AS PER 2008 NEC"},{"number":"321180","date":"2011-02-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-13","scope":"INSTALLATION OF DUCT WORK AND DIFFUSERS 3RD FLOOR AREA IN CONJUNCTION WITH ALTS PERMIT AP226489"},{"number":"322948","date":"2011-03-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-05-23","scope":"RENOVATE EXISTING X RAY ROOM TO ACCOMODATE NEW MEDICAL EQUIPMENT TO CREATE A CVIR PROCEDURE ROOM FOR HOSPITAL PER PLAN. STATE APPROVAL ID# 200801-20, DATED 9/9/10."},{"number":"322762","date":"2011-03-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-29","scope":"INSTALL 154 CAT6 PLENUM CABLES FOR JOICE AND DATA APPLICATIONS, INSTALL CLIENT PROVIDED COMMUNICATION CABINET AS PER 2008 NEC (SOUTH DIST)"},{"number":"327192","date":"2011-03-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"ADD 2 DUCT DETECTORS 2 NEW AHU AS PER 2008 NEW"},{"number":"334796","date":"2011-04-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-03-27","scope":"RELOCATION OF (13) SPRINKLERS FOR HOSPITAL."},{"number":"334335","date":"2011-05-03","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2011-05-03","scope":"FOR THE ERECTION OF A ONE (1) STORY DETACHED TEMPORARY TRAILER (8'6\" X 52'0\") WITH SIX FT HIGH CHAIN LINK FENCE TWO SIDES AND REMOVAL OF SEVEN OPEN AIR OFF STREET PARKING SPACE FOR ERECTION OF MRI TEMPORARY TRAILER FOR THE EXTENSION OF AN EXISTING HOSPITAL COMPLEX. SIZE AND LOCATION AS SHOWN ON THE APPLICATION. FOR THE TEMPORARY \"MRI\" TRAILER ACCESSORY TO THE EXISTING HOSPITAL COMPLEX IN THE SAME LOT PREVIOUSLY APPROVED"},{"number":"352995","date":"2011-07-20","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-05-08","scope":"CONSTRUCT A TEMPORARY WOOD RAMP & LANDING ENTRANCE TO ACCESS TEMPORARY MOBILE MRI TRAILER AS PART OF HOSPITAL COMPLEX, INSTALL A FIRE RESISTANT FABRIC CANOPY, FENCING, ADDITIONAL CIVIL SITE WORK AS INDICATED PER PLANS AND SPECIFICATIONS."},{"number":"353921","date":"2011-07-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-12-05","scope":"FOR PARTIAL INTERIOR DEMOLITION AND INTERIOR ALTERATIONS TO INCLUDE FRAMING AND GYPSUM WALLBOARD FOR NEW PARTITION WALLS, SUSPENDED CEILING AND THE CREATION OF ACCESSIBLE BATHROOMS ON THE FIRST FLOOR FOR G.I., SURGERY AND WOUND CARE UNIT AS PER PLANS."},{"number":"356032","date":"2011-08-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-12-05","scope":"INTERIOR ALTERATIONS (PLUMBING) - INSTALLATION TO COMPLY WITH THE APPROVED PLANS: P-1, P-2, P-3, P-4 AND P-5 - (49)FIXTURES TOTAL - NOTE: EXCEPTIONS MEDICAL GAS/VACUUM/OXYGEN"},{"number":"355583","date":"2011-08-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-01-12","scope":"FURNISH AND INSSTALL NEW LIGHTS, SWITCHES, RECEPTS, 6 NEW PANELS AS PER 2008 NEC (SOUTH DISTRICT)"},{"number":"356025","date":"2011-09-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-05","scope":"DUCTWORK RENOVATIONS TO EXISTING HOSPITAL SPACE AS PER PLAN."},{"number":"361376","date":"2011-10-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-01-12","scope":"FURNISH AND INSTALL NEW PULL STATIONS, STROBES, AV DEVICES AND SMOKE DETECTORS ON 1ST FLOOR AS PER NFPA72 (SOUTH DISTRICT)"},{"number":"369867","date":"2011-10-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-11-28","scope":"REMOVE AND REINSTALL EXISTING BRANCH LINE IN PIPING IN THE RAMP CORRIDOR"},{"number":"375579","date":"2011-11-25","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-04-18","scope":"INSTALL PIPE SANITARY/VENT AND WATERS FOR 5 FIXTURES, 1 WC, 2 LAVS, & 2 SINKS (HOSPITAL)"},{"number":"364784","date":"2011-11-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-12-05","scope":"INSTALL NEW SPRINKLERS, CONNECT TO EXISTING SYSTEM, AS PER PLAN AND CALCS."},{"number":"375988","date":"2011-12-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-04-18","scope":"RELOCATING (3) SPRINKLERS HEADS IN THE RESPIRATOR WORK AREA."},{"number":"369174","date":"2011-12-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-02-15","scope":"INSTALL 221 CAT6 PLENUM CABLES FOR VOICE AND DATA APPLICATIONS. INSTALL TJU-PROVIDED EQUIPMENT CABINETS AND NETWORK EQUIPMENT AS PER 2008 NEC (AKA 1300 WOLF STREET (1ST FLOOR ONLY))(SOUTH DISTRICT)"},{"number":"21339","date":"2012-01-06","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2012-01-06","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 12/23/2012"},{"number":"374778","date":"2012-01-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-04-18","scope":"RENOVATION TO EXISTING SPACE INCLUDING NEW WALL, CEILING AND FLOORING."},{"number":"375571","date":"2012-02-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-04-18","scope":"INSTALL DUCTWORK, REGISTERS AND DIFFUSERS"},{"number":"375626","date":"2012-04-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-06-28","scope":"REPLACING RECEPTS, SWITCHES AND LIGHTS IN BREAK ROOM AND UTILITY AREAS AS PER 2008 NEC (CC DIST)(METHODIST HOSPITAL)"},{"number":"422571","date":"2012-09-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-01-11","scope":"REPLACE EXISTING FIXTURES WITH NEW, 10 EM RECEPTS, 20 NORMAL RECEPTS, REWORK NEW BRANCH CIRCUITS INTO EXISTING PANELS AS PER 2008 NEC (HOSPITAL)"},{"number":"430667","date":"2012-10-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-01-07","scope":"RENOVATION OF PATIENT ROOMS AND MEDICATION ROOM IN 2ND FLOOR CCU SUITE."},{"number":"432819","date":"2012-10-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-01-16","scope":"REPLACE EXISTING FIXTURES WITH NEW, ADD 10 DOWN LIGHTS AND PROVIDE NEW RECEPTS AT HEAD WALLS. ALL WORK DONE IN ACCORDANCE WITH 2008 NEC(HOSPITAL COMPLEX)(SOUTH DIST)"},{"number":"436561","date":"2012-11-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-01-07","scope":"2ND FLOOR - CCU - METHODIST HOSPITAL - INTERIOR ALTERATIONS (PLUMBING) - RENOVATIONS OF PATIENT ROOMS - (8)WATER CLOSETS, (8)LAVATORIES AND (9)SINKS"},{"number":"436795","date":"2012-12-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-01-20","scope":"FOR INSTALLATION OF HVAC SYSTEM AS PER PLANS."},{"number":"443035","date":"2012-12-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-01-02","scope":"RELOCATE (2) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW WALL AND CEILING LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"22074","date":"2012-12-19","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2012-12-19","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 12/18/2013"},{"number":"444759","date":"2013-01-04","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-07-09","scope":"INTERIOR ALTERATIONS OF FORMER PATIENT ROOM TO CREATE CENTRAL TELEMETRY MONITORING ROOM."},{"number":"442968","date":"2013-01-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-07-09","scope":"FOR INTERIOR ALTERATIONS WITH NO CHANGE IN OCCUPANCY CLASSIFICATION WITHIN AN EXISTING THREE (3) STORY MIXED-USE HOSPITAL BUILDING W. HELIPORT TO INCLUDE ERECTION OF INTERIOR PARTITIONS FOR PATIENT, NURSE STATION, EXAM, CONFERENCE, LINEN STORAGE, & OFFICE SPACES, INSTALLATION OF WALL IMPACT PROTECTION AT EXISTING CORRIDORS & LOBBY WALLS, & INSTALLATION OF NEW CEILING FIXTURES WITHIN EXISTING GRID; BUILDING IS FULLY SPRINKLERED. INTERIOR DEMOLITION TO BE LIMITED TO AREAS AS SHOWN IN APPROVED PLANS & ALL PA DEPT. OF HEALTH REQUIRED INFECTION CONTROL MEASURES TO BE MAINTAINED THROUGHOUT DURATION OF ALL PERMITTED CONSTRUCTION. ASBESTOS ABATEMENT TO BE COMPLETED BY A CITY OF PHILADELPHIA CERTIFIED ASBESTOS CONTRACTOR PRIOR TO COMMENCEMENT OF PERMITTED WORK."},{"number":"449819","date":"2013-01-24","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-09-27","scope":"INSTALLATION OF ONE KITCHEN SINK"},{"number":"448187","date":"2013-01-24","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-07-24","scope":"INTERIOR ALTERATIONS FOR EXISTING X-RAY ROOM IN EMERGENCY DEPARTMENT AS PER PLANS."},{"number":"446297","date":"2013-01-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-03-25","scope":"CONVERT PATIENT RM INTO CENTRAL MON ROOM ADD RECPT FOR NEW MONITORS, NEW LGT W/SW, PULL VOLT MONITOR CABLE. ADD SMOKE DETECT & HORN/STROBE TO EXIST SYSTEM, WILL SUBMIT FIRE ALARM LATER AS PER NEC 2008 & NFPA 72"},{"number":"448878","date":"2013-02-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-03-07","scope":"FURNISH & INSTALL NEW 100AMP 480V XRAY FEEDER & SHUNT TRIP CB 13-NEW LIGHT 6-SWITCHES & RACEWAY FOR XRAY EQUIPMENT (HOSPITAL)"},{"number":"453440","date":"2013-02-13","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-03-07","scope":"RELOCATE 8 SPRINKLERS ON THE 1ST FLOOR EMERGENCY DEPT."},{"number":"448039","date":"2013-02-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-06-26","scope":"FURNISH AND INSTALL 16 SMOKE DETECTORS 13 HORN/STROBES AND 1 STROBES PER 2008 NEC & NFPA 72 (HEALTH CARE FACILITY)"},{"number":"449251","date":"2013-02-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-05-04","scope":"ADD ONE SMOKE DETECTORS AND ON HORN/STROBE TO EXISTING SYSTEM PER 2008 NEC & NFPA 72 (HEALTH CARE FACILITY)"},{"number":"454524","date":"2013-02-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-09-11","scope":"RELOCATE 23 SPRINKLERS ON THE 3RD FLOOR"},{"number":"449671","date":"2013-02-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-03-20","scope":"FOR THE REMOVAL AND INSTALLATION OF NEW DUCTWORK WITH DIFFUSERS AND REGISTERS LOCATED ON 1ST FLOOR RADIOLOGY ROOM."},{"number":"451874","date":"2013-03-14","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-07-09","scope":"DEMOLISH AND REPLACE 25 FIXTURES ON 3RD FLOOR OF METHODIST HOSPITAL"},{"number":"451879","date":"2013-03-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-07-09","scope":"REMOVE AND REINSTALL NEW REHEAT COILS AND MODIFY DUCTWORK TO ACCOMODATE NEW INSTALL FURNISH AND INSTALL NEW GRILLES, REGISTERS AND DIFFUSERS AS PER PLANS."},{"number":"463137","date":"2013-04-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-10-30","scope":"RELOCATE 6 GRD'S FOR NEW TENANT FITOUT"},{"number":"467670","date":"2013-04-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-07-09","scope":"RELOCATE 7 SPRINKLERS ON THE 2ND FLOOR"},{"number":"466156","date":"2013-04-30","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2013-04-30","scope":"EXISTING ELEVATOR PENTHOUSE ON 3 STORY BUILDING. CONSTRUCT AIR HANDLING UNIT AND CHILLER UNIT ON ROOF OF EXISTING HOSPITAL BUILDINGS TO SUPPORT MECHANICAL NECESSITY OF EXISTING HOSPITAL"},{"number":"473432","date":"2013-05-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-08-12","scope":"INTERIOR DEMO, RENOVATIONS FOR NEW INSTALLATION OF NUCLEAR CAMERA ROOM AND EQIUPMENT, HOT LAB. NEW DRYWALL, ACOUSTICAL CEILING, FLOORING, AND FINISHES,FURNISHINGS, INSTALLATION OF SUPPORTS FOR NUCLEAR XRAY MACHINERY EQUIPMENT INSTALLATION PER MANUFACTURERS PLANS, RELOCATION OF EXISTING DIFFUSERS INCLUDED. ADDITIONAL PERMITS REQ: ELECTRICAL, HVAC (INSTALLATION OF FUTURE RTU/AHU) , SPRINKLERS, PLUMBING"},{"number":"475360","date":"2013-06-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-01-30","scope":"INSTALL 2 SINKS (1-FIXTURE REPLACEMENT & 1-NEW (HOSPITAL)"},{"number":"472058","date":"2013-06-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-10-03","scope":"FURNISH AND INSTALL 16 NEW LIGHTS 2 DIMMERS 5 RECEPTACLES, NEW SERVICE FOR AFIU 20 ON ROOF PER 2008 NEC (HEALTH CARE FACILITY)"},{"number":"473505","date":"2013-06-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL 2 DUCT DETECTORS PER 2008 NEC & NFPA 72 (HEALTH CARE FACILITY)"},{"number":"476152","date":"2013-06-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-01-30","scope":"RENOVATION OF EXISTING SUITE TO CREATE A NEW UROLOGY DOCTOR'S OFFICE. WORK INCLUDES NON-STRUCTURAL DEMOLITION AS PER PLANS."},{"number":"475344","date":"2013-07-09","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-08-12","scope":"INSTALLATION HVAC, NEW ROOF AHU FOR 2ND FLOOR, NEW ACCESSORY DUCTWORK FOR NEW RADIOLOGY ROOM, ACCESSORY MECHANICALS."},{"number":"486362","date":"2013-08-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-11-26","scope":"RENOVATION OF RADIOLOGY DEPARTMENT TO CREATE A NEW MRI TREATMENT ROOM, CONTROL ROOM AND EQUIPMENT ROOM, WORK INCLUDES NON STRUCTURAL DEMOLITION, DRYWALL, ACOUSTICAL, FINISHES AS PER PLANS. ADDITIONAL PERMITS ARE REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND SUPPRPESSION."},{"number":"484209","date":"2013-08-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-01-06","scope":"FURNISH & INSTALL NEW FEEDER TO GE MDP PANEL FOR MRI ALSO NEW 200AMP 480 VOLT FEEDER AND PANEL FOR CHILLER & EXISTING EQUIPMENT PER 2008 NEC (HEALTH CARE FACILITY)"},{"number":"485067","date":"2013-08-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-11-26","scope":"RUN NEW PIPING TO SERVICE 3 SINKS (2 NEW AND 1 EXISTING)"},{"number":"487966","date":"2013-09-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-11-27","scope":null},{"number":"496478","date":"2013-10-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-11-26","scope":"FOR THE INSTALLATION OF SIX (6) SPRINKLERS HEADS AND RELOCATION OF FIVE (5) SPRINKLERS IN ACCORDANCE WITH NFPA 13 AS PER APPROVED PLANS TO TIE INTO AN EXISTING FIRE SUPPRESSION SYSTEM."},{"number":"485081","date":"2013-10-31","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-11-26","scope":"FOR THE INSTALLATION OF NEW DUCTWORK, HVAC REFRIGERANT PIPING, GRILLS, REGISTERS, DIFFUSERS, AND VAV BOXES TO CONNECT TO EXISTING HVAC SYSTEM, INCLUDING REFRIGERANT PIPING AND NEW ROOFTOP CHILLER."},{"number":"22737","date":"2014-02-19","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2014-02-19","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 02/19/2015"},{"number":"498106","date":"2014-02-28","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-02-28","scope":"FOR THE REMOVAL AND REPLACEMENT OF AN EXISTING ILLUMINATED FLAT WALL SIGN (SIGN \"A\"; SMALLER THAN ORIGINAL), THE LEGALIZATION AND REFACING OF ONE (1) DOUBLE-FACED, INTERNALLY ILLUMINATED PROJECTING SIGNS (SIGN \"B\") AND ONE (1) INTERNALLY ILLUMINATED FLAT WALL SIGN (SIGN \"D\"), AND FOR THE ERECTION OF ONE (1) SINGLE FACED, INTERNALLY ILLUMINATED FREE STANDING SIGN (SIGN \"C\"), ONE (1) INTERNALLY ILLUMINATED FLAT WALL (SIGN \"E\") AND TWO (2) NON-ILLUMINATED PROJECTING SIGNS (SIGN \"F\"). SIZE AND LOCATION AS SHOWN IN APPLICATION. FOR USE AS SIGNS ACCESSORY TO AN EXISTING HOSPITAL USE."},{"number":"519583","date":"2014-03-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-06-09","scope":"MINOR RECONFIGURATION TO EMERGENCY DEPARTMENT AREA INCLUDING HANDICAP RAMP @ EXTERIOR. - HOSPITAL"},{"number":"526665","date":"2014-03-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-05-16","scope":"INSTALL SANITARY AND WATER PIPE TO SERVE NEW FIXTURES WATER CLOSET,LAV AND SINK (HEALTH CARE FACILITY)"},{"number":"521783","date":"2014-03-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-22","scope":"PROVIDE POWER & CONNECTION TO NEW FURNITURE PARTIAL IU EM DEPT AS PER NEC 2008 (HEALTH CARE FACILITY)"},{"number":"524247","date":"2014-04-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-05-16","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING HOSPITAL, ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF PARITION WALLS, PROVIDE FINISHES AND ACCESSIBLITY IMPROVEMENTS THROUGHOUT NURSES STATION, WAITING ROOM AND STAFF LOUNGE. ALL WORK TO BE DONE PER APPROVED PLANS AND DOH LETTER.BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK."},{"number":"523011","date":"2014-04-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-22","scope":"F & I 12-NEW LIGHTS & 9-RECEPTACLES AS PER NEC 2008 (HEALTH CARE)"},{"number":"522682","date":"2014-04-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-16","scope":"ALTERATIONS TO EXISTING MECHANICAL SYSTEM AS PER PLANS."},{"number":"525325","date":"2014-04-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-09-06","scope":"DISCONNECT, DEMO WIRING CONDUIT FEOM EXISITING EQUIPMENT,PROVIDE POWER TO 3 CHILLERS,8 PUMPS AND INSTALL 8 VFD UNITS PER 2008 NEC (HEALTH CARE FACILITY)"},{"number":"525584","date":"2014-04-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-03","scope":"FURNISH AND INSTALL BOOSTER PANEL 1 VISUAL AND 2 SPEAKERS PER 2008 NEC & NFPA 72(HEALTH CARE FACILITY)"},{"number":"535659","date":"2014-05-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-05-16","scope":"WE WILL BE RELOCATING 7 SPRINKLERS IN THE 1ST FLOOR BREAK ROOM & NURSE STATION AT METHODIST HOSPITAL"},{"number":"542561","date":"2014-06-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-02-24","scope":"RELOCATE 1 SPRINKLER HEAD"},{"number":"558159","date":"2014-10-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-04-14","scope":"LEVEL I STRUCTURAL ALTERATIONS TO INCLUDE FLOORING AND RAILING REPLACEMENT AND SKYLIGHT AND COLUMN ENCLOSURE INSTALLATION IN AN EXISTING HOSPITAL AS PER APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"571376","date":"2014-10-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-12-16","scope":"BREEZEWAY (GROUND FLOOR REAR ENTRANCE) - REMOVE (3)AREA DRAINS - RE-INSTALL (2)AREA DRAINS (NO ADDITIONAL PIPING) - REMOVE EXISTING RAINWATER CONDUCTOR AND INSTALL (1)NEW"},{"number":"574418","date":"2014-11-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-02-18","scope":"RELOCATE 11 HEADS TO FIT NEW WALL LAYOUT"},{"number":"579273","date":"2014-12-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-02-18","scope":"1ST FLOOR PHARMACY ALTERATIONS - INSTALL (1)MOP RECEPTOR AND (1)SINK - TIE INTO EXISTING UTILITIES - WORK WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"574222","date":"2014-12-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-04-23","scope":"INSTALL F+I(20)NEW LIGHTS,(15)RECEPTACLES,(3)SWITCHES AND (2)LIGHT SENSORS AS PER 2008 NEC (SOUTH DISTRICT)"},{"number":"575703","date":"2014-12-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-05-14","scope":"FURNISH AND INSTALL NEW LIGHTS,SWITCHES,RECEPTACLES,IN 16 PATIENT ROOMS,2 NEW PANELS,2 AHU AND 2 PUMPS PER 2008 NEC (HEALTH CARE FACILITY)"},{"number":"578857","date":"2014-12-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-02-18","scope":"*LEVEL II ALTERATION* PHARMACY CLEAN ROOM RENOVATIONS AND IMPROVEMENTS, INCLUDING ASSOCIATED SPACE ON BASEMENT LEVEL."},{"number":"580030","date":"2014-12-30","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-12-30","scope":"FOR THE REMOVAL AND REPLACEMENT OF AN EXISTING STATICALLY ILLUMINATED FLAT WALL SIGN (SIGN \"A\"; SMALLER THAN ORIGINAL). SIZE AND LOCATION AS SHOWN IN APPLICATION. FOR USE AS A SIGN ACCESSORY TO AN EXISTING HOSPITAL USE."},{"number":"577916","date":"2015-01-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-03","scope":"FURNISH AND INSTALL SPEAKER STROBE AND 1 STROBE PER 2008 NEC & NFPA 72 (HEALTH CARE FACILITY)"},{"number":"579251","date":"2015-02-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-02-19","scope":"FOR THE REMOVAL AND REPLACEMENT OF EXITING ROOF TOP UNIT AND NEW ASSOCIATED DUCTOWORK AS PER APPROVED PLANS."},{"number":"575726","date":"2015-02-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-05","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM IN THIRD FLOOR OF EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS AND DOH APPROVALS."},{"number":"583534","date":"2015-02-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL NEW SMOKE DETECTORS IN BASEMENT PER 2008 NEC & NFPA 72(HEALTH CARE)"},{"number":"587249","date":"2015-04-02","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2015-08-03","scope":"FOR THE REMOVAL OF EXISTING SIGN. FOR THE ERECTION OF ONE (1) FLATWALL ACCESSORY SIGN AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL WORK."},{"number":"597375","date":"2015-04-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"PROVIDE CONDUIT WIRING FOR STORM WATER PUMPS AS PER 2008 NEC (SOUTH DISTRICT)"},{"number":"599056","date":"2015-05-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-06-01","scope":"LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY CLASSIFICATION) TO KITCHEN AND DINING ROOMS (NEW L.O. SIGN) IN SUB-BASEMENT LEVEL TO INCLUDE INSTALLATION OF TEMPORARY KITCHEN (CONSTRUCTION TRAILERS) AS PER APPROVED PLANS AND IN ACCORDANCE WITH PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. WORK TO BE PERFORMED IN THREE (3) PHASES PER PLANS. AMENDED PERMIT REQUIRED IF SPECIAL INSPECTIONS ARE NECESSARY. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**"},{"number":"611094","date":"2015-05-19","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-05-17","scope":"RELOCATE 65 SPRINKLERS FOR MAIN KITCHEN FOR PHASES 1,2, & 3 EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS"},{"number":"613402","date":"2015-05-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-04-05","scope":"104 SPRINKLER HEADS"},{"number":"23538","date":"2015-06-04","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2015-06-05","scope":"06/05/2015 ERECT ASSEMBLY TENT (10'X100') METHODIST HOSPITAL"},{"number":"609729","date":"2015-06-08","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-05-17","scope":"INSTALL FIXTURES AND CONNECTIONS"},{"number":"613510","date":"2015-06-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-05-17","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM FOR EXISTING HOSPITAL BASEMENT KITCHEN AND DINING ROOM TO INCLUDE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT AS PER APPROVED PLANS. SEE ALTERATIONS PERMIT 599056 FOR PA DOH APPROVAL AND AIR."},{"number":"604574","date":"2015-06-12","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-11-02","scope":"FOR LEVEL II ALTERATIONS TO PATIENT ROOMS IN AN EXISTING HEALTH FACILITY ON THE THIRD FLOOR LEVEL. ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"576296","date":"2015-06-23","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-03-28","scope":"INTERIOR PLUMBING ALTERATIONS TO THE 3RD FLOOR SOUTH PATIENT ROOMS - WORK WILL COMPLY WITH THE APPROVED PLANS AND THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"611424","date":"2015-06-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-06-01","scope":"REFIT PANEL BOARDS,INSTALL TEMPORARY PANELS/EQUIP,NEW LIGHTING,CIRCUITING FOR NEW KITCHEN INSTALLATION FOR 25-30 KITCHEN EQUIPMENT INCLUDING 120 LIGHTS AND 55 CKTS PER 2008 NEC. INSTALLATION TO COMPLY WITH ARTICLE 210.8(B)(2) OF THE 2008 NEC."},{"number":"623044","date":"2015-08-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-06-01","scope":"REMOVE EXISTING DEVICES DURING RENOVATION.REINSTALL WHEN CEILING COMPLETED.ADD 3 NEW MODULES FOR ANSUL SYSTEM AND RETEST AND CERTIFY PER NFPA 72 (HEALTH CARE)"},{"number":"641793","date":"2015-10-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL NEW STROBES, SPEAKER/STROBES, PULL STATIONS, SMOKE DETECTORS AND DUCT DECTETORS AS PER NFPA72 (SOUTH DISTRICT)"},{"number":"651890","date":"2015-12-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"PROVIDE AND INSTALL PLENUM RATE CAT 6 COAX FIBER CABLING FOR VOICE AND DATE 135 LOCATION,CAT 6 RATED JACKS/RG-6 AND FACE PLATES.LONGEST RUN APPROX 200' ALL CABLING WILL BE SUPPORTED AS REQUIRED PER 2008 NEC (HEALTH CARE)"},{"number":"659200","date":"2016-01-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-04","scope":"INSTALLATION OF ONE (1) ETL & NSF LISTED COMMERCIAL KITCHEN EXHAUST HOOD (FOUR SECTIONS) WITHIN AN EXISTING HOSPITAL KITCHEN AS PER APPROVED PLANS. DUCTWORK AND FANS TO BE INSTALLED UNDER SEPARATE PERMIT. ***SEPARATE PERMIT SHALL BE REQUIRED FOR INSTALLATION OF AN APPROVED AUTOMATIC FIRE SUPRESSION SYSTEM***"},{"number":"663673","date":"2016-01-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-02-25","scope":"INSTALL 1 ANSUL R102 WET CHEMICAL SYSTEM EZ STANDARD KITCHEN FIRE SUPPRESSION- FOR THE INSTALLATION OF NEW WET CHEMICAL KITCHEN HOOD FIRE SUPPRESSION SYSTEM AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"677759","date":"2016-03-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-06-30","scope":"LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING OUTPATIENT MEDICAL OFFICES WITHIN AN EXISTING HOSPITAL COMPLEX AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"681057","date":"2016-04-18","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-06-30","scope":"1ST FLOOR - OB-GYN OFFICE RENOVATIONS (METHODIST HOSPITAL - RADIOLOGY ONCOLOGY BUILDING) - INTERIOR PLUMBING ALTERATIONS PER THE APPROVED PLANS AND THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"687306","date":"2016-04-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-11-30","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.* RELOCATE 5 SPRINKLER HEADS TO CONFIRM WITH NEW CEILINGS PER NFPA 13 REQUIREMNTS."},{"number":"687501","date":"2016-05-04","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2025-05-29","scope":"LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING MEDICATION ROOM (6TH FLOOR) WITHIN AN EXISTING HOSPITAL COMPLEX AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"689910","date":"2016-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-11-29","scope":"*FOR RELOCATION OF FOUR (4) DIFFUSERS ON 6TH FLOOR OF HOSPITAL* EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"681069","date":"2016-05-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-11-29","scope":"RENOVATION, RELCOATION OF DUCTWORK, DIFFUSERS AND INSTALL NEW GRD'S CONNECT TO EXISTING SYSTEM FOR NEW FLOOR LAYOUT."},{"number":"681595","date":"2016-05-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-23","scope":"ELECTRICAL WORK RECEPTACLES & LIGHTING & NURSE CALL 3-DOME LIGHTS & 2-PULL CORDS REWORK EXISTING SYSTEM AS PER NEC 2008 & FIRE ALARM DEVICES & SPEAKERS STROBES AS PER NFPA 72 SOUTH DISTRICT"},{"number":"24228","date":"2016-05-23","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2016-05-23","scope":"6/3/16 ERECT ASSEMBLY TENT 10X150"},{"number":"689660","date":"2016-06-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RELOCATE 3-2X2 FIXTURES AND 3 EMERGENCY RECEPTS AS PER NEC 2008 (SOUTH DISTRICT) RELOCATING 3 FIRE ALARM DEVICES AS PER NFPA72"},{"number":"699148","date":"2016-06-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-07-22","scope":"RELOCATE (2) SPRINKLER HEADS."},{"number":"24433","date":"2016-08-29","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2016-08-29","scope":"9/16/16 ERECT ASSEMBLY TENT 40X70"},{"number":"738313","date":"2016-11-21","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-06-12","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"735664","date":"2016-11-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-08-22","scope":"FOR INTERIOR ALTERATIONS TO ACCOMMODATE THE REPLACEMENT OF MEDICAL EQUIPMENT. PROPOSED WORK ON 2ND FLOOR OF EXISTING HOSPITAL BUILDING. NO CHANGE OF OCCUPANCY. EXISTING BUILDING FULLY SPRINKLERED. ALL WORK PER DOH APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"739744","date":"2017-01-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-01-10","scope":"INSTALL (1) 25KVA TRANSFORMERS, (1) 40 AMP SHUNT TRIP DISCONNECT,(1) DISCONNECT 40 AMP (1) REC, (1) EPO, CONDUIT & WALKER DUCT FOR EQUIPMENT VENDOR PER 2008 NEC (HEALTH CARE)SOUTH DISTRICT"},{"number":"740444","date":"2017-01-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"EXPIRED","completedDate":"2017-08-03","scope":"MECHANICAL ALTERATIONS TO MECHANING PIPE. INSTALLATIONOF HVAC EQUIPMENT."},{"number":"24910","date":"2017-05-24","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2017-05-24","scope":"6/2/17 ERECT ASSEMBLY TENT 10X140"},{"number":"798792","date":"2017-07-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-06","scope":"RELOCATING GRD'S IN TENANTS SPACES."},{"number":"800581","date":"2017-07-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-01-25","scope":"LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) WITHIN AN EXISTING HOSPITAL COMPLEX AS PER PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"802234","date":"2017-08-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-08-06","scope":"FOR INTERIOR ALTERATIONS TO EXISTING SPACE ON THIRD FLOOR, INCLUDING NEW INTERIOR PARTITIONS AND INTERIOR FINISHES, AS PER APPROVED PLANS."},{"number":"807085","date":"2017-08-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-01-16","scope":"RELOCATE (8) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"808312","date":"2017-08-15","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-08-06","scope":"TO AMEND PERMIT# 802234 TO REFLECT CORRECT OWNER AS: THOMAS JEFFERSON UNIVERSITY- METHODIST DIV."},{"number":"811433","date":"2017-09-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-04-02","scope":"ALTERATIONS: INTERIOR PLUMBING; 4 FIXTURES; 2ND FLOOR; HOSPITAL- THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004"},{"number":"805593","date":"2017-10-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-25","scope":"FURNISH & INSTALL 100AMP 3 PHASE 480VOLT SHUNT TRIP BREAKER, 16 NEW LIGHTS, SWITCHES & RECEPTS AS PER 2008 NEC (SOUTH DISTRICT)"},{"number":"828065","date":"2017-11-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-11-30","scope":"REPLACEMENT OF ONE SINK"},{"number":"824536","date":"2017-11-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-06","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW O.R. STORAGE ROOM ON THE THIRD FLOOR OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS."},{"number":"830680","date":"2017-11-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-08-06","scope":"RELOCATE (11) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"833391","date":"2017-11-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-06-04","scope":"RELOCATE 7 SPRINKLER HEADS TO CONFORM WITH NEW CEILING LAYOUT PER NFPA 13.EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"831495","date":"2017-11-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-06-04","scope":"LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING HEADACHE CENTER (6TH FLOOR) WITHIN AN EXISTING HOSPITAL COMPLEX AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"836441","date":"2017-12-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-06-04","scope":"PLUMBING ALTERATIONS IN AN EXISTING HOSPITAL USE - DEMO WATER CLOSET, LAV, FLOOR DRAIN, SHOWER AND MOP RECEPTOR, REMOVE 1 SINK AND REPLACE WITH NEW"},{"number":"841854","date":"2018-01-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-04","scope":"INSTALLATION OF 26 NEW 2X4 LIGHTS 5 2X2 LIGHT 22 NEW 20AMP RECEPTACLES AND CIRCUITS AS PER 2008 NEC (SOUTH DISTRICT) INSTALL 2 HORN STROBES AS PER NFPA72"},{"number":"839702","date":"2018-02-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-10","scope":"LIGHTING DEMO 6 (2X2) FIXTURES AND REINSTALL THE SAME, INSTALL 11 (2X4) FIXTURES, AND 11 NEW RECEPTS AS PER 2008 NEC (SOUTH DISTRICT) INSTALL FIRE ALARM 1 NAC PANEL, 2 STROBES& 2 HORN STROBES AS PER NFPA72"},{"number":"836431","date":"2018-02-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-04","scope":"FOR ALTERATIONS TO AN EXISTING HVAC MECHANICAL SYSTEM TO INCLUDE ASSOCIATED DUCTWORK, REGISTERS/DIFFUSERS/GRILLES, AND REFRIGERANT PIPING.."},{"number":"861940","date":"2018-04-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-08-06","scope":"ALTERATIONS TO ROOFTOP DUNNAGE & OTHER SUPPORT FRAMING FOR FUTURE HVAC ROOFTOP EQUIPMENT PER APPROVED PLANS. SEPARATE PERMIT REQ'D FOR ANY MECH. & ELEC. WORK."},{"number":"865142","date":"2018-05-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-25","scope":"F&I (3) VFD'S FOR AHU-1, G-4-1 & EFG-1. AS PER 2008 NEC. (SOUTH DISTRICT)"},{"number":"25597","date":"2018-06-01","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2018-07-02","scope":"06/01/2018 ERECT TWO(2) ASSEMBLY TENTS; 10'X 70' EXPIRES 06/04/2018"},{"number":"868081","date":"2018-06-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-06","scope":"INSTALL TWO (2) EXHAUST FANS AND REMOVE AND INSTALL AIR HANDLER AND CONDENSING UNIT ON ROOF AS PER APPROVED PLANS."},{"number":"933044","date":"2018-12-31","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2025-05-29","scope":"RENOVATIONS OF SPACE TO ACCOMODATE A NEW ADVANCED SPINE CENTER OPERATION ROOM. INSTALLATION OF STRUCTURAL STEEL TO SUPPORT NEW OR EQUIPMENT. RENOVATIONS TO INCLUDE REMOVAL & REPLACEMENT OF EXISTING NON-STRUCTURAL WALLS, CEILINGS,FLOORING, , HVAC, SPRINKLER ,ELECTRICAL. **SEPERATE PERMITS WILL BE REQUIRED FOR HVAC, SPRINKLER & ELECTRICAL PERMITS**"},{"number":"941056","date":"2019-03-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-31","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCE WITH ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. *DOH APPROVAL SUBMITTED UNDER APP #933044*"},{"number":"962629","date":"2019-04-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-10-10","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"966414","date":"2019-04-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-10-01","scope":"25 FIXTURES 2 EXITS 1 INVERTER 7 DIMMER 2 CEILING SENSORS 2 ISOLATION PANELS 1 400 ASCO SWITCH 2 400AMP PANELS 1 30KVA TRANSFORMER FIRE ALARM DEVICES INTO NEW CEILING TILES FULL ALL LOW VOLTAGE CABLING AS PER 2008 NEC AND NFPA 72"},{"number":"966534","date":"2019-04-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-01-31","scope":"PRESCRIPTIVE ALTERATIONS TO CONVERT EXIST. SPACE INTO BRONCHOSCOPY SUITE PER APPROVED PLANS & AS APPROVED BY PA DOH. SEPARATE PERMIT REQ'D FOR ANY MECH. & ELEC. WORK."},{"number":"974653","date":"2019-05-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-10-09","scope":"3RD FLOOR OPERATIG ROOM EZ PERMIT 20 SPRINKLER HEADS RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"941058","date":"2019-05-14","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2021-01-21","scope":"ALTERATIONS: INTERIOR PLUMBING; HOSPITAL COMPLEX;ADVANCED SPINE CENTER 3RD FLOOR OPERATION ROOM;NEW HAND WASHING SINK AND 2 ELECTRIC WATER HEATERS"},{"number":"976907","date":"2019-05-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-10-09","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO INSTALL ONE (1) EXHAUST FAN, DUCTWORK AND ONE (1) EXHAUST GRILLE FOR 3RD FLOOR, ROOM 3214 WITHIN AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS."},{"number":"26333","date":"2019-05-29","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2019-05-29","scope":"05/31/19 ERECT ASSEMBLY TENT 10X150"},{"number":"972910","date":"2019-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-11","scope":"F & I NEW BRANCH CIRCUIT FOR EXHAUST FAN EF-1 AS PER NEC 2017 SOUTH DISTRICT"},{"number":"1015168","date":"2019-10-28","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-10-28","scope":"FOR THE REMOVAL AND REPLACEMENT OF A EXISTING COURTYARD WITH IMPROVED PEDESTRIAN PATHWAYS, SIDEWALKS, AMD LANDSCAPED AREAS. FOR THE ERECTION OF CANOPIES OVER EXISTING PEDESTRIAN WALKWAYS FOR THE REMOVAL AND REPLACEMENT OF A FEW PARKING SPACES, ERECTION OF ADA RAMPS ERECTION OF RAISED PLANTERS ACCESSORY TO AN EXISTING HOSPITAL COMPLEX. ."},{"number":"1025623","date":"2019-12-13","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-09-16","scope":"EXTERIOR ENTRANCE RENOVATION TO INCLUDE: THE REMOVAL AND REPLACEMENT OF AN EXISTING COURTYARD WITH IMPROVED PEDESTRIAN PATHWAYS, SIDEWALKS, AND LANDSCAPED AREAS, THE ERECTION OF CANOPIES OVER EXISTING PEDESTRIAN WALKWAYS, THE REMOVAL AND REPLACEMENT OF A PARKING SPACES, ERECTION OF ADA RAMPS, AND THE ERECTION OF RAISED PLANTERS' ACCESSORY TO AN EXISTING HOSPITAL COMPLEX. . **SCOPE OF WORK TO INCLUDE UNDERPINNING** **IBC 2018** AMENDED AS OF 2.24.2021: Modify footing along \"L\" line per ASI # 4 drawings dated 9/14/20."},{"number":"1029123","date":"2020-01-08","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-03-03","scope":"INSTALL 476 SMOKE DETECTORS--INSTALL 205 STROBES--INSTALL 186 SPEAKERS--INSTALL 18 BOOSTER PANELS--INSTALL 2 MAIN PANELS AND ASSOCIATED ANNUNCIATOR PANELS--RECONNECT EXISTING EQUIPMENT AS PER NFPA72. (SOUTH DISTRICT)"},{"number":"1029125","date":"2020-01-08","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-04-29","scope":"INSTALL 2 PANELS, INSTALL LIGHTING CONTROLS--INSTALL 167 LIGHT FIXTURES (ALL TYPES) AS PER THE 2017 NEC (SOUTH DIST.) *BUILDING PERMIT# 1025623*"},{"number":"1035012","date":"2020-02-11","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2022-10-25","scope":"HVAC, TO INCLUDE, INSTALLATION OF NEW SPLIT SYSTEM AND CONDENSING UNIT, WITH ASSOCIATED PIPING, FOR EXTERIOR ENTRANCE RENOVATIONS AS PER PLANS."},{"number":"ZP-2020-004274","date":"2021-03-17","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"FOR THE REMOVAL OF ONE (1) DOUBLE FACED FREE-STANDING SIGN (SIGN 2), ONE (1) FLAT WALL SIGN (SIGN 53), TO REPLACE FREESTANDING SIGN (SIGN 22) WITH SINGLE FACED NON-ILLUMINATED FREE-STANDING SIGN (SIGN 104), FOR THE INSTALLATION OF TWO (2) DOUBLE FACED PROJECTING SIGNS WITH STATIC ILLUMINATION (SIGN 124, SIGN 125), SEVEN (7) WINDOW SIGNS (SIGNS 108, 117, 119, 120, 121, 133 AND 134), THREE (3) DIRECTIONAL SIGNS (SIGNS 201, 203, 204), TWELVE (12) NON-ILLUMINATED FLAT WALL SIGNS (SIGNS 101, 106, 107, 109, 110, 111, 112b, 113, 114, 115, 116 AND 206) AND TWELVE (12) FLAT WALL SIGNS WITH STATIC ILLUMINATION (SIGNS 103, 105, 112a, 112c, 118, 122, 123a, 123b (2 NUMBERS), 123c, 131, 140 and 202) ACCESSORY TO EXISTING HOSPITAL (SIZE AND LOCATION AS SHOWN ON PLANS)"},{"number":"CP-2021-000802","date":"2021-03-24","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-09-07","scope":"INSTALLATION OF VERTICAL PLATFORM LIFT IN CONFERENCE ROOM FOR THE ACCESS TO THE EXTERIOR COURTYARD."},{"number":"EP-2021-002897","date":"2021-03-24","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-05-25","scope":"INSTALLATION OF VERTICAL PLATFORM LIFT IN CONFERENCE ROOM FOR THE ACCESS TO THE EXTERIOR COURTYARD."},{"number":"CP-2021-003152","date":"2021-06-04","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-02-16","scope":"FOR RENOVATIONS TO ENTRANCE OF EXISTING HEALTH FACILITY WITH THE REPLACEMENT OF WINDOWS AS SHOWN PER APPROVED PLANS. WINDOWS TO BE INSALL WORK TO BE DONE PER APPROVED PLANS, IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2021-007418","date":"2021-08-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-01-07","scope":"REMOVE THE EXISTING LIGHT FIXTURE, EQUIPMENT AND DEVICES MAINTAIN THE EXISTING CIRCUITS FOR CONNECTION TO NEW LIGHT FIXTURES AND THE EXISTING RELOCATED EQUIPMENT AND DEVICES. ALL WORK IN ACCORDANCE WITH THE 2017 NEC."},{"number":"PP-2021-017737","date":"2021-09-27","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2022-11-01","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2022-007306","date":"2022-05-10","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2023-07-19","scope":"Remove and replace section of 6\" underground domestic cold water distribution service line IN at Emergency Room Entrance on Wolf Street."},{"number":"CP-2022-002883","date":"2022-06-02","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-05-03","scope":"FOR LEVEL II INTERIOR ALTERATIONS AT THE BASEMENT LEVEL OF AN EXISTING HOSPITAL (GROUP I-2, CONDITION 2). ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC AND PA DOH APPROVALS. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. **ASBESTOS ABATEMENT REQUIRED**"},{"number":"MP-2022-003242","date":"2022-06-29","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-03-04","scope":"FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM TO INCLUDE DEMOLITON OF AN EXISTNG EXHAUST FAN AND INSTALLATION OF TWO (2) NEW EXHAUST FANS ON THE ROOF, NEW GRDs AT THE BASEMENT LEVEL, AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. APPLIANCES TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2022-002883 FOR ASSOCIATED BUILDING ALTERATIONS PERMIT."},{"number":"PP-2022-009045","date":"2022-07-20","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-02-26","scope":"Demo existing sink, and install new Scrub Sink."},{"number":"FP-2022-001826","date":"2022-07-20","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-02-29","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (6) Sprinkler Heads"},{"number":"EP-2022-008491","date":"2022-08-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-03-27","scope":"Fire alarm equipment replacement, one for one changeout of the existing equipment with new. Make terminations needed for installation as per nfpa 72"},{"number":"EP-2022-008795","date":"2022-09-02","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-03-27","scope":"Fire alarm equipment replacement, one for one changeout of the existing equipment with new. Make terminations needed for installation asper nfpa 72"},{"number":"EP-2023-004571","date":"2023-07-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-12-18","scope":"Renovations to the Basement Pharmacy. Lighting, switches, lighting controls, receptacles, HVAC wiring, fire alarm, and empty conduits and boxes for low voltage systems as per 2017 nec and nfpa 72"},{"number":"CP-2023-005898","date":"2023-10-23","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-04-02","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS PREVIOUSLY APPROVED. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS AND PROVIDE FINISHES/FURNISHINGS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* ALL WORK TO BE DONE AS PER APPROVED PLANS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"MP-2023-005169","date":"2023-12-05","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-04-02","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"PP-2023-016101","date":"2023-12-09","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-04-02","scope":"Demo existing sink, and install new Scrub Sink."},{"number":"EP-2023-011455","date":"2023-12-20","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-04-02","scope":"Install Lighting, lighting controls, receptacles, equipment power wiring, fire alarm replacement, empty conduits and boxes for future low voltage systems. AS PER NEC 2017"},{"number":"CP-2024-000068","date":"2024-01-08","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-06-07","scope":"FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, WALL INFILLS, REPAIR CEILINGS AND FLOORS AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP WORK."},{"number":"PP-2024-000138","date":"2024-01-09","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2026-03-02","scope":"Demo existing Sink and Install new Scrub Sink"},{"number":"MP-2024-000075","date":"2024-01-17","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-03","scope":"FOR THE INSTALLATION OF HVAC APPLICANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS."},{"number":"FP-2024-000075","date":"2024-01-17","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-05-28","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 14 Heads"},{"number":"EP-2024-000670","date":"2024-01-31","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-05-21","scope":"PROVIDE POWER FOR THE NEW SIEMENS EQUIPMENT. INSTALL NEW LIGHT FIXTURES NORMAL & EMERGENCY, SWITCHES & UL924 RELAYS USING THE EXISTING LIGHTING CIRCUITS. INSTALL RECEPTACLES, EPO BUTTON, DOOR SWITCH, & XRAY IN USE FIXTURE. REMOVE & REINSTALL (1) STROBE FIRE ALARM DEVICE. ALL WORK IN ACCORDANCE WITH THE 2017 NEC."},{"number":"PP-2024-000471","date":"2024-02-12","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-05-28","scope":"Installation of new sink"},{"number":"MP-2024-000165","date":"2024-02-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-05-28","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2024-006828","date":"2024-07-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-12-09","scope":"Replace Existing Nurse Call Panels with New. Replace Existing Nurse Call Devices With New as per 2017 NEC."},{"number":"EP-2025-000834","date":"2025-02-13","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"INSTALL POWER TO NEW RECEPTACLE OUTLETS FOR SERVING NINE PLUG IN NURSE'S CALL PANELS ACCORDING TO THE 2017 NEC AND PER PLANS."},{"number":"FP-2025-000326","date":"2025-02-24","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-04-02","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 7 Heads"},{"number":"CP-2026-001275","date":"2026-03-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR LEVEL I ALTERATIONS TO AN EXISTING BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE WORK RELATED TO NEW MEP SYSTEMS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2026-003228","date":"2026-04-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"Provide power wiring for duct heaters and rooftop unit(s). Work includes installation of feeders and/or branch circuits, disconnecting means, conduit, conductors, supports, terminations, and grounding/bonding as required. Coordinate electrical connections with mechanical equipment requirements, including proper overcurrent protection and equipment ratings. All work shall be performed in accordance with the 2017 NEC and per approved plans."}],"storyTag":"Torn down & rebuilt","storyDelta":null,"timeline":[{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Alterations"},{"y":2024,"k":"permit","w":"Addition and/or Alterations"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"viol","w":"4 L&I violations"},{"y":2025,"k":"insp","w":"L&I: 3 failed, 1 passed"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"viol","w":"5 L&I violations"},{"y":2026,"k":"insp","w":"L&I: 3 failed, 1 passed"}],"rented":false,"licenses":[{"number":"199874","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"METHODIST HOSPITAL GIFT SHOP (THE LITTLE BISTRO)","legalName":"METHODIST HOSPITAL GIFT SHOP","address":"2301 S BROAD ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2001-06-28","latestIssueDate":"2001-06-28","expirationDate":"2002-04-30","inactiveDate":null},{"number":"285931","type":"Hazardous Materials","status":"Inactive","businessName":"METHODIST HOSPITAL","legalName":"METHODIST HOSPITAL","address":"2301 S BROAD ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2001-11-01","latestIssueDate":"2007-09-25","expirationDate":"2007-11-30","inactiveDate":null},{"number":"286796","type":"Public Garage / Parking Lot","status":"Inactive","businessName":"METHODIST HOSPITAL","legalName":"METHODIST HOSPITAL","address":"2301 S BROAD ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2004-02-12","latestIssueDate":"2012-01-24","expirationDate":"2012-12-31","inactiveDate":null},{"number":"208303","type":"Food Preparing and Serving (30+ SEATS)","status":"Active","businessName":"METHODIST HOSPITAL","legalName":"METHODIST HOSPITAL","address":"2301 S BROAD ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2004-05-09","latestIssueDate":"2026-04-06","expirationDate":"2027-04-30","inactiveDate":null},{"number":"298743","type":"Vendor - Newsstand","status":"Inactive","businessName":"SAMMY BONACCURSO","legalName":"SAMMY BONACCURSO","address":"2301 S BROAD ST","revenueCode":"3414","rentalCategory":null,"units":null,"issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","expirationDate":"2009-06-30","inactiveDate":null},{"number":"636444","type":"Vendor - Newsstand","status":"Active","businessName":"SHAYONA NEWSTAND INC.","legalName":"SHAYONA NEWSTAND INC.","address":"2301 S BROAD ST","revenueCode":"3414","rentalCategory":null,"units":null,"issuedDate":"2014-07-29","latestIssueDate":"2026-03-05","expirationDate":"2027-03-31","inactiveDate":null},{"number":"646226","type":"Food Preparing and Serving","status":"Active","businessName":"METHODIST HOSPITAL GIFT SHOP (THE LITTLE BISTRO)","legalName":"METHODIST HOSPITAL GIFT SHOP","address":"2301 S BROAD ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2014-10-31","latestIssueDate":"2026-04-06","expirationDate":"2027-04-30","inactiveDate":null}],"licenseActivity":[{"number":"646226","type":"Food Preparing and Serving","businessName":"METHODIST HOSPITAL GIFT SHOP (THE LITTLE BISTRO)","legalName":"METHODIST HOSPITAL GIFT SHOP","issuedDate":"2014-10-31","latestIssueDate":"2026-04-06","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"636444","type":"Vendor - Newsstand","businessName":"SHAYONA NEWSTAND INC.","legalName":"SHAYONA NEWSTAND INC.","issuedDate":"2014-07-29","latestIssueDate":"2026-03-05","closureDate":null,"expirationDate":"2027-03-31","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"298743","type":"Vendor - Newsstand","businessName":"SAMMY BONACCURSO","legalName":"SAMMY BONACCURSO","issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","closureDate":"2009-06-30","expirationDate":"2009-06-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"208303","type":"Food Preparing and Serving (30+ SEATS)","businessName":"METHODIST HOSPITAL","legalName":"METHODIST HOSPITAL","issuedDate":"2004-05-09","latestIssueDate":"2026-04-06","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"286796","type":"Public Garage / Parking Lot","businessName":"METHODIST HOSPITAL","legalName":"METHODIST HOSPITAL","issuedDate":"2004-02-12","latestIssueDate":"2012-01-24","closureDate":"2012-12-31","expirationDate":"2012-12-31","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"285931","type":"Hazardous Materials","businessName":"METHODIST HOSPITAL","legalName":"METHODIST HOSPITAL","issuedDate":"2001-11-01","latestIssueDate":"2007-09-25","closureDate":"2007-11-30","expirationDate":"2007-11-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"199874","type":"Food Establishment, Retail Permanent Location","businessName":"METHODIST HOSPITAL GIFT SHOP (THE LITTLE BISTRO)","legalName":"METHODIST HOSPITAL GIFT SHOP","issuedDate":"2001-06-28","latestIssueDate":"2001-06-28","closureDate":"2002-04-30","expirationDate":"2002-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-23","signals":[{"kind":"record-pressure","level":"elevated","title":"Records to verify together","summary":"More than one separately dated public record deserves a current-status check.","evidence":["8 open L&I violations","failed L&I inspection activity in 2023, 2025, 2026"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."},{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["8 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #68462: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"13 permits not marked completed: 245433 (EXPIRED), 687501 (Expired), 740444 (EXPIRED), 933044 (Expired), 941058 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"8 open L&I violations","finding":"25 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"building-certifications","level":"attention","title":"A life-safety certification appears expired","finding":"Facade Report: Safe with Repair through Feb 23, 2031; Sprinkler Certification: Certified through Jul 31, 2025; Fire Alarm Certification: Certified through Apr 25, 2026; Special Hazards Certification: Certified through May 8, 2026; Damper Certification: Certified through Jan 14, 2027","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"12 failed, 13 passed, and 1 CLOSED investigation outcome are in the fetched history; the latest dated visit was PASSED on Jun 23, 2026.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Establishment, Retail Permanent Location #199874: Inactive; Hazardous Materials #285931: Inactive; Public Garage / Parking Lot #286796: Inactive; Vendor - Newsstand #298743: Inactive","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"abatement","level":"verify","title":"A reduced taxable assessment is not a verified abatement","finding":"OPA’s numeric assessment fields show a reduced taxable assessment; BlockReport has no official program determination for this parcel.","why":"The numeric treatment can reflect an improvement abatement or another exemption. It does not identify the ordinance, approval, start or end date, or continuation requirements after a transfer. Once OPA verifies a specific active abatement, many common programs attach the benefit to the property for the remaining term rather than ending automatically at sale, but some require a new-owner filing and continued qualifying use or tax compliance.","action":"Obtain the OPA exemption/abatement determination and history, then underwrite the buyer’s bill from the verified program terms.","url":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/get-a-property-tax-abatement/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as commercial. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}