{"asOf":"2026-07-27T01:40:42.109Z","block":"200-299 N BROAD ST","blockUrl":"https://philadelphia.blockreport.homes/block/200-299-n-broad-st","address":"222-48 N BROAD ST","parcelNumber":"772025002","source":"https://property.phila.gov/?p=772025002","ownerType":"absentee","kind":"commercial","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"YA1","buildingCodeNew":"640","buildingClass":"HEALTH FAC HOSP MAS+OTH","buildingClassNew":"HOSPITAL","useLabel":"Commercial","owner":"BROAD STREET HEALTHCARE","coOwner":"PROPERTIES LLC","marketValue":20169100,"landAssessment":8964100,"improvementAssessment":11205000,"livableArea":448200,"yearBuilt":1928,"lastSale":{"price":26200000,"date":"2018-01-11T05:00:00Z"},"openViolations":5,"violations":[{"number":"1462643","date":"2009-03-04","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1462642","date":"2009-03-04","code":"FC-505.1/1","title":"EXT ADDRESS NUMBERS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318416","date":"2009-03-04","code":"FC-914.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318419","date":"2009-03-04","code":"FC-409.5/1","title":"SHELTER DRILL CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318418","date":"2009-03-04","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318417","date":"2009-03-04","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318415","date":"2009-03-04","code":"FC-914.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318414","date":"2009-03-04","code":"FC-914.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318413","date":"2009-03-04","code":"FC-2701.5/1","title":"HAZMAT-LIC REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318412","date":"2009-03-04","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318411","date":"2009-03-04","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1410388","date":"2009-07-30","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2776978","date":"2011-02-24","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"2776979","date":"2011-02-24","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"2737976","date":"2012-12-06","code":"FC-904.11/4","title":"AFES-COMM KITCH SERVICE & CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737981","date":"2012-12-06","code":"PM-506.2/1","title":"ELEC PROPERLY INSTALL-NR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737980","date":"2012-12-06","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737965","date":"2012-12-06","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737966","date":"2012-12-06","code":"FC-1008.1/2","title":"EGRESS DOOR HI RISE OPEN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737969","date":"2012-12-06","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737970","date":"2012-12-06","code":"FC-607.2/1","title":"ELEVATORS POST EMERGENCY SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737971","date":"2012-12-06","code":"FC-703.1/1","title":"FIRE-MAINTAIN ASSEMBLY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737973","date":"2012-12-06","code":"FC-901.6/10","title":"FIRE SUPP-REPLACE SPRKLR HEAD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737974","date":"2012-12-06","code":"FC-901.6/12","title":"FIRE DEPT CONNECT REP DAM CAPS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737975","date":"2012-12-06","code":"FC-901.6/13","title":"FIRE SUPP DRY CHEM SYS MAINT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737977","date":"2012-12-06","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2826162","date":"2013-05-08","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2826163","date":"2013-05-08","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120383","date":"2014-02-11","code":"FC-1027.2/1","title":"EGRESS CLEAR OBSTRUCTION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120381","date":"2014-02-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120382","date":"2014-02-11","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120384","date":"2014-02-11","code":"FC-2703.5/4","title":"HAZMAT ID ENTRANCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120385","date":"2014-02-11","code":"FC-2705.1/2","title":"HAZMAT-LEVEL CONTROL-LOW-LIQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120386","date":"2014-02-11","code":"FC-315.2/4","title":"INT MATERIAL STORAGE EQUIP RM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120390","date":"2014-02-11","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120391","date":"2014-02-11","code":"FC-915.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3507857","date":"2015-02-18","code":"FC-13-915","title":"CERTIFICATION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3507858","date":"2015-02-18","code":"FC-13-915.1","title":"FIRE ALARM TESTED/CERTIFIED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3507856","date":"2015-02-18","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4156424","date":"2016-11-28","code":"A-301.1/54","title":"PERMP- INST NEW PLUMBING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4156425","date":"2016-11-28","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2025-097475","date":"2025-12-16","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097496","date":"2025-12-16","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097494","date":"2025-12-16","code":"F-912.7","title":"FDC INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097500","date":"2025-12-16","code":"PM15-301","title":"VACANT STRUCTURE & LAND","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097489","date":"2025-12-16","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"3135421","date":"2014-04-05","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3735147","date":"2015-10-08","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4059239","date":"2016-08-23","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4256615","date":"2016-11-09","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"193102","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2009-03-04","completedDate":"2009-10-20","violations":[{"number":"1462643","date":"2009-03-04","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1462642","date":"2009-03-04","code":"FC-505.1/1","title":"EXT ADDRESS NUMBERS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"193125","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2009-03-04","completedDate":"2009-09-16","violations":[{"number":"1318416","date":"2009-03-04","code":"FC-914.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318419","date":"2009-03-04","code":"FC-409.5/1","title":"SHELTER DRILL CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318418","date":"2009-03-04","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318417","date":"2009-03-04","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318415","date":"2009-03-04","code":"FC-914.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318414","date":"2009-03-04","code":"FC-914.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318413","date":"2009-03-04","code":"FC-2701.5/1","title":"HAZMAT-LIC REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318412","date":"2009-03-04","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1318411","date":"2009-03-04","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"208787","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2009-07-31","completedDate":"2009-08-11","violations":[{"number":"1410388","date":"2009-07-30","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"267314","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-02-25","completedDate":null,"violations":[{"number":"2776978","date":"2011-02-24","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"2776979","date":"2011-02-24","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"362414","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-12-10","completedDate":"2013-05-08","violations":[{"number":"2737976","date":"2012-12-06","code":"FC-904.11/4","title":"AFES-COMM KITCH SERVICE & CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737981","date":"2012-12-06","code":"PM-506.2/1","title":"ELEC PROPERLY INSTALL-NR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737980","date":"2012-12-06","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737965","date":"2012-12-06","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737966","date":"2012-12-06","code":"FC-1008.1/2","title":"EGRESS DOOR HI RISE OPEN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737969","date":"2012-12-06","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737970","date":"2012-12-06","code":"FC-607.2/1","title":"ELEVATORS POST EMERGENCY SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737971","date":"2012-12-06","code":"FC-703.1/1","title":"FIRE-MAINTAIN ASSEMBLY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737973","date":"2012-12-06","code":"FC-901.6/10","title":"FIRE SUPP-REPLACE SPRKLR HEAD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737974","date":"2012-12-06","code":"FC-901.6/12","title":"FIRE DEPT CONNECT REP DAM CAPS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737975","date":"2012-12-06","code":"FC-901.6/13","title":"FIRE SUPP DRY CHEM SYS MAINT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737977","date":"2012-12-06","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"379598","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-05-08","completedDate":"2013-07-24","violations":[{"number":"2826162","date":"2013-05-08","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2826163","date":"2013-05-08","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"418868","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-02-11","completedDate":"2014-04-28","violations":[{"number":"3120383","date":"2014-02-11","code":"FC-1027.2/1","title":"EGRESS CLEAR OBSTRUCTION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120381","date":"2014-02-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120382","date":"2014-02-11","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120384","date":"2014-02-11","code":"FC-2703.5/4","title":"HAZMAT ID ENTRANCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120385","date":"2014-02-11","code":"FC-2705.1/2","title":"HAZMAT-LEVEL CONTROL-LOW-LIQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120386","date":"2014-02-11","code":"FC-315.2/4","title":"INT MATERIAL STORAGE EQUIP RM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120390","date":"2014-02-11","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3120391","date":"2014-02-11","code":"FC-915.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"469053","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2015-02-18","completedDate":"2015-04-15","violations":[{"number":"3507857","date":"2015-02-18","code":"FC-13-915","title":"CERTIFICATION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3507858","date":"2015-02-18","code":"FC-13-915.1","title":"FIRE ALARM TESTED/CERTIFIED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3507856","date":"2015-02-18","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"565069","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2016-11-29","completedDate":"2017-01-05","violations":[{"number":"4156424","date":"2016-11-28","code":"A-301.1/54","title":"PERMP- INST NEW PLUMBING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4156425","date":"2016-11-28","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2025-134307","type":"NOTICE OF VIOLATION","priority":"ADMINISTRATIVE NOTICE OF VIOLATION","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2025-12-16","completedDate":null,"violations":[{"number":"VI-2025-097475","date":"2025-12-16","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097496","date":"2025-12-16","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097494","date":"2025-12-16","code":"F-912.7","title":"FDC INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097500","date":"2025-12-16","code":"PM15-301","title":"VACANT STRUCTURE & LAND","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-097489","date":"2025-12-16","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"511771","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3135421","date":"2014-04-05","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"639019","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3735147","date":"2015-10-08","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"706158","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"4059239","date":"2016-08-23","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"673063","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"4256615","date":"2016-11-09","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2009,"n":12,"worst":null},{"y":2011,"n":2,"worst":null},{"y":2012,"n":12,"worst":null},{"y":2013,"n":2,"worst":null},{"y":2014,"n":9,"worst":null},{"y":2015,"n":4,"worst":null},{"y":2016,"n":4,"worst":null},{"y":2025,"n":5,"worst":null}],"investigations":[{"caseNumber":"70092","date":"2006-07-10","type":"CI INSP","status":"FAILED"},{"caseNumber":"95706","date":"2006-12-28","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"95706","date":"2007-02-01","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"101553","date":"2007-02-12","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"95706","date":"2007-02-12","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"101553","date":"2007-02-26","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"101553","date":"2007-03-12","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"101553","date":"2007-03-28","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"101553","date":"2007-04-11","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"101553","date":"2007-04-18","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"101553","date":"2007-05-08","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"70092","date":"2007-12-10","type":"CI INSP","status":"PASSED"},{"caseNumber":"193102","date":"2009-03-04","type":"CI INSP","status":"FAILED"},{"caseNumber":"193125","date":"2009-03-04","type":"CI INSP","status":"FAILED"},{"caseNumber":"193125","date":"2009-04-30","type":"CI INSP","status":"FAILED"},{"caseNumber":"208787","date":"2009-08-07","type":"CI TANK","status":"PASSED"},{"caseNumber":"193125","date":"2009-09-15","type":"CI INSP","status":"PASSED"},{"caseNumber":"193102","date":"2009-09-15","type":"CI INSP","status":"FAILED"},{"caseNumber":"193102","date":"2009-10-19","type":"CI INSP","status":"PASSED"},{"caseNumber":"267314","date":"2011-02-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"267314","date":"2011-07-27","type":"CI INSP","status":"FAILED"},{"caseNumber":"267314","date":"2012-01-09","type":"CI INSP","status":"FAILED"},{"caseNumber":"267314","date":"2012-01-09","type":"CI INSP","status":"CLOSED"},{"caseNumber":"362414","date":"2012-12-06","type":"CI INSP","status":"FAILED"},{"caseNumber":"362414","date":"2013-03-12","type":"CI INSP","status":"FAILED"},{"caseNumber":"267314","date":"2013-04-23","type":"PRECOURT","status":"FAILED"},{"caseNumber":"362414","date":"2013-05-08","type":"CI INSP","status":"PASSED"},{"caseNumber":"379598","date":"2013-05-08","type":"CI INSP","status":"FAILED"},{"caseNumber":"379598","date":"2013-06-12","type":"CI INSP","status":"FAILED"},{"caseNumber":"379598","date":"2013-07-23","type":"CI INSP","status":"PASSED"},{"caseNumber":"418868","date":"2014-02-11","type":"CI INSP","status":"FAILED"},{"caseNumber":"418868","date":"2014-03-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"418868","date":"2014-04-28","type":"CI INSP","status":"PASSED"},{"caseNumber":"469053","date":"2015-02-18","type":"CI INSP","status":"FAILED"},{"caseNumber":"469053","date":"2015-03-30","type":"CI INSP","status":"FAILED"},{"caseNumber":"469053","date":"2015-04-15","type":"CI INSP","status":"PASSED"},{"caseNumber":"565069","date":"2016-11-28","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"565069","date":"2017-01-05","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"CF-2025-134307","date":"2025-12-16","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-134307","date":"2026-02-10","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-134307","date":"2026-07-15","type":null,"status":"FAILED"}],"inspYears":[{"y":2006,"fails":2,"passes":0},{"y":2007,"fails":5,"passes":5},{"y":2009,"fails":4,"passes":3},{"y":2011,"fails":2,"passes":0},{"y":2012,"fails":2,"passes":0},{"y":2013,"fails":4,"passes":2},{"y":2014,"fails":2,"passes":1},{"y":2015,"fails":2,"passes":1},{"y":2016,"fails":1,"passes":0},{"y":2017,"fails":0,"passes":1},{"y":2025,"fails":1,"passes":0},{"y":2026,"fails":2,"passes":0}],"taxOwed":5859.23,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":true,"totalDue":5859.23,"principalDue":0,"penaltyDue":2558.18,"interestDue":2877.95,"otherChargesDue":423.1,"yearsOwed":1,"oldestYearOwed":2021,"mostRecentYearOwed":2021,"mostRecentPaymentDate":"2021-04-05","assessmentYear":2022,"totalAssessment":20169100,"taxableAssessment":20169100,"exemptAbatementAssessment":0,"homesteadValue":0,"netTaxAfterHomestead":282327.06,"actionableAtSnapshot":true,"paymentAgreementAtSnapshot":false,"bankruptcyAtSnapshot":false,"assessmentUnderAppealAtSnapshot":false,"yearMonth":"202206"},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.95732493668147,"lng":-75.16309442221093,"geom":{"type":"Polygon","coordinates":[[[-75.162710596,39.957581187],[-75.162851279,39.956893638],[-75.163274845,39.956946447],[-75.163224596,39.957196351],[-75.163336882,39.957212494],[-75.163313277,39.957325744],[-75.163547543,39.9573499],[-75.163478928,39.957675256],[-75.162710596,39.957581187]]]},"liDistrict":"CENTRAL WEST","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19102","beds":null,"baths":null,"stories":null,"lotArea":44821,"zoning":"CMX5","grade":"B","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"222 N SEPULVEDA BLVD, EL SEGUNDO CA, 90245","mailOut":true,"appeals":[],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":2,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":40300000,"taxable":40300000,"land":9254700,"improvement":31045300,"taxableLand":9254700,"taxableImprovement":31045300,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":40300000,"taxable":40300000,"land":9254700,"improvement":31045300,"taxableLand":9254700,"taxableImprovement":31045300,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":32480000,"taxable":32480000,"land":7625900,"improvement":24854100,"taxableLand":7625900,"taxableImprovement":24854100,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":20169100,"taxable":20169100,"land":8964100,"improvement":11205000,"taxableLand":8964100,"taxableImprovement":11205000,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":20169100,"taxable":20169100,"land":8964100,"improvement":11205000,"taxableLand":8964100,"taxableImprovement":11205000,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":20169100,"taxable":20169100,"land":8964100,"improvement":11205000,"taxableLand":8964100,"taxableImprovement":11205000,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":20169100,"taxable":20169100,"land":8964100,"improvement":11205000,"taxableLand":8964100,"taxableImprovement":11205000,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":20169100,"taxable":20169100,"land":8964100,"improvement":11205000,"taxableLand":8964100,"taxableImprovement":11205000,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":20169100,"taxable":20169100,"land":8964100,"improvement":11205000,"taxableLand":8964100,"taxableImprovement":11205000,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":20169100,"taxable":20169100,"land":8964100,"improvement":11205000,"taxableLand":8964100,"taxableImprovement":11205000,"exemptLand":0,"exemptImprovement":0}],"taxNow":282327,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"30936","date":"2007-01-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-05-02","scope":"INSTALL NEW DRY VALVE TO CONVERT THE MANUAL DRY STANDPIPES TO AUTOMATIC DRY STANDPIPES SYSTEM ONLY."},{"number":"48052","date":"2007-01-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-05-02","scope":"RENOVATIONS IN NORTH TOWER ON PART OF 7TH FLOOR."},{"number":"53741","date":"2007-01-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-10-21","scope":"INSTALL 2 HAND SINKS, INSTALL 1 SCRUB SINK, RELOCATION 1 SCRUB SINK"},{"number":"58863","date":"2007-02-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-05-02","scope":"RELOCATE 5 SPRINKLER HEADS (8TH FLOOR NORTH TOWER)"},{"number":"58857","date":"2007-02-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-05-02","scope":"RELOCATE 5 SPRINKLER HEADS (7TH FLOOR N. TOWER)"},{"number":"63562","date":"2007-03-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-13","scope":"DEMO AND RE-INSTALLATION OF NEW CATH LAB MACHINERY, THIS PERMIT WILL REPLACE AP#50811 DUE TO INCORRECT ADDRESS (CENTER CITY DISTRICT)"},{"number":"63579","date":"2007-03-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-13","scope":"RELOCATE EXISTING LIGHTS AND POWER, THIS PERMIT WILL REPLACE AP#50818 DUE TO INCORRECT ADDRESS (CENTER CITY DISTRICT)"},{"number":"65089","date":"2007-03-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-03","scope":"INSTALL 18 CAT 5E PLENUM RATED CABLES ON 18TH FLOOR. LONGEST RUN 100'."},{"number":"106963","date":"2007-10-03","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2008-02-19","scope":"AMEND PERMIT # 101900 TO REFLECT CORRECT ADDRESS"},{"number":"106090","date":"2007-10-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-02-19","scope":"RENOVATIONS AS PER PLAN"},{"number":"108182","date":"2007-10-09","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-10-25","scope":"UPGRADES TO EXISTING HOSPITAL ROOMS AND STAFF AREAS. MINOR PIPE MODIFICATIONS. 11 SINKS, 17 LAV'S, 15 WATER CLOSETS, 12 SHOWERS."},{"number":"108859","date":"2007-10-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-02-19","scope":"RELOCATE 73 SPRINKLER HEADS ON 15TH FLOOR OF NORTH TOWER BLDG."},{"number":"108865","date":"2007-11-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION OF PATIENT ROOMS, NEW LIGHTING, POWER EXISTING."},{"number":"113122","date":"2007-11-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-02-28","scope":"EP LAB RENOVATIONS AS PER PLAN."},{"number":"110239","date":"2007-11-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-19","scope":"INSTALL DUCTWORK."},{"number":"112773","date":"2007-11-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL FIRE ALARM DEVICES PER PLANS (CC DIST)"},{"number":"122324","date":"2007-12-20","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-05-28","scope":"RENOVATIONS FOR RADIOLOGY ROOM ON 2ND FLR."},{"number":"136832","date":"2008-03-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-05-28","scope":"RELOCATE 8 SPRINKLER HEADS, 2ND FLOOR, SOUTH TOWER"},{"number":"166844","date":"2008-07-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-03-04","scope":"INTERIOR DEMO & ALTERATIONS, UPGRADES, FIT OUTS, AS PER PLANS"},{"number":"170675","date":"2008-08-18","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-10-21","scope":"FIXTURE INSTALLATION"},{"number":"176199","date":"2008-09-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-11-17","scope":"RELOCATE 17 SPRINKLER HEADS ON 4TH FL (4401-4413)"},{"number":"174190","date":"2008-09-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-03-04","scope":"DEMO AND ALTERATION EXISTING DUCT WORK, DIFFUSERS AND INSTALLATION OF NEW MECHANICALS/ACCESSORIES FOR RECONFIGURING/UPGRADING OF EXISTING FLOOR SPACE."},{"number":"170824","date":"2008-09-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-10-29","scope":"4TH FL: INSTALL 80 CAT5E PLENUM CABLES, 20-30 18/2 SHIELDED PLENUM CABLES, 12TH FL: 20 CAT5E PLENUM CABLES, MISC CABLES ON 15TH FL, 12 CAT5E PLENUM CABLES, LONGEST RUN 180' AS PER 2005 NEC (CC DISTRICT)"},{"number":"181435","date":"2008-10-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-11-17","scope":"RELOCATE 16 SPRINKLER HEADS (4TH FLOOR NORTH TOWER)"},{"number":"188846","date":"2008-11-18","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-03-04","scope":"RELOCATE 2 SPRINKLER HEADS, 12TH FLOOR"},{"number":"223443","date":"2009-06-30","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-10-27","scope":"INSTALL 1 WATER CLOSET, INSTALL 4 LAVATORIES, INSTALL 10 FLOOR DRAINS, INSTALL 8 EXAM SINKS"},{"number":"223272","date":"2009-07-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-05-17","scope":"NEW POWER AND LIGHT RENOVATE DIALYSIS UNIT APPROX 60 RECEPTS AND 45 FIXTURES AS PER 2005 NEC (CC DISTRICT)"},{"number":"226880","date":"2009-07-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-09-22","scope":"RELOCATE 50 SPRINKLER HEADS (1ST, 2ND & 4TH FLOOR CLASSROOMS - NEW COLLEGE BUILDING)"},{"number":"228636","date":"2009-07-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-12-07","scope":"RELOCATE 20 SPRINKLER HEADS (11TH FLOOR HAHNEMANN - NEW COLLEGE)"},{"number":"228168","date":"2009-08-14","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-09-22","scope":"FIXTURE INSTALLATION"},{"number":"225392","date":"2009-08-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-04","scope":"INSTALL (30-40) CATEGORY 5E PLENUM CABLES, LONGEST RUN 100 FEET AS PER 2005 NEC (CC DIST)"},{"number":"239233","date":"2009-09-25","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-01-11","scope":"RELOCATE 65 SPRINKLER HEADS (8TH FLOOR NEW COLLEGE)"},{"number":"240085","date":"2009-09-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-12-31","scope":"RELOCATE 21 SPRINKLER HEADS (4TH FLOOR NEW COLLEGE)"},{"number":"244949","date":"2009-11-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-05-17","scope":"INSTALL PANEL & UPGRADE KITCHEN EQUIPMENT."},{"number":"261381","date":"2010-02-08","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-06-04","scope":"RELOCATE 25 SPRINKLER HEADS (4TH FLOOR - NEW COLLEGE BLDG.)"},{"number":"258117","date":"2010-02-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-06-04","scope":"INTERIOR ALTERATIONS AS PER PLANS"},{"number":"258183","date":"2010-02-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-04","scope":"INTERIOR ALTERATIONS TO HVAC PER PLANS"},{"number":"264937","date":"2010-03-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-06-04","scope":"RELOCATE 1 SPRINKLER HEAD (3RD FLOOR, MRI NORTH TOWER)"},{"number":"264554","date":"2010-03-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-06-04","scope":"INSTALL 2 SINKS"},{"number":"264611","date":"2010-03-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-05-17","scope":"INSTALL 30 LIGHT FIXTURES, 25 RECEPTACLES & 1 PANEL."},{"number":"308829","date":"2010-10-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-05-31","scope":"RELOCATE 15 SPRINKLER HEADS(COMMERCIAL)"},{"number":"317210","date":"2010-12-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-02-06","scope":"RELOCATE 9 SPRINKLE HEADS (7TH FLOOR NORTH TOWER - CATH LAB)"},{"number":"319944","date":"2011-01-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-07-26","scope":"RELOCATE 7 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"326267","date":"2011-02-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-03-25","scope":"RELOCATE 8 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"331175","date":"2011-04-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-07-01","scope":"RELOCATION OF SPRINKLERS TO ACCOMODATE NEW WALL AND CEILING LAYOUT FOR 8TH FLOOR MEDICAL HOSPITAL"},{"number":"352333","date":"2011-07-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-07-18","scope":"INSTALLING INDIRECT WASTE LINE FOR COMMERCIAL ICE MAKER UNIT, ALSO WATER SUPPLY FOR ICE MAKER UNIT"},{"number":"368782","date":"2011-10-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-03-27","scope":"FOR THE INSTALLATION OF A HVAC & EXHAUST SYSTEM WITHIN EXISTING LABORTORIES. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. THIS WORK SHALL BE PERFORMS BY A CONTRACTOR(S) LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"367371","date":"2011-10-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-03-27","scope":"FOR INTERIOR ALTERATIONS WITHIN AN EXISTING BUILDING LOCATED ON THE 17TH FLOOR. ALTERATIONS INCLUDE MODIFICATIONS WITHIN NOTED LABS AS SHOWN ON THE APPROVED PLANS. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. THIS WORK ACTIVITY SHALL BE PERFORMED BY A CONTRACTOR & SUB-CONTRACTORS LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"371577","date":"2011-11-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-03-27","scope":"MODIFICATIONS FOR NEW LAB LAYOUT PLUS THE ADDITION OF EYEWASH & SAFETY SHOWERS."},{"number":"373114","date":"2011-11-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-12-05","scope":"RELOCATE 16 SPRINKLER HEADS (NEW COLLEGE BLDG. - 15TH FLOOR)"},{"number":"399079","date":"2012-05-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-12-05","scope":"RELOCATING SPRINKLERS TO ACCOMODATE NEW WALL AND CEILING LAYOUT FOR 8TH FLOOR OF HOSPITAL IN ACCORDANCE WITH NFPA 13. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"449845","date":"2013-01-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-07-03","scope":"HVAC, DUCTWORK ON THE 17TH FLOOR OFFICE AREA AS PER PLANS. SEE ALTERATION PERMIT AP#449119 FOR PLANS."},{"number":"449119","date":"2013-01-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-07-03","scope":"INTERIOR RENOVATIONS TO THE OFFICE AREA ON THE 17TH FLOOR AS PER PLANS. MECHANICAL PERMIT ISSUED UNDER AP#449845."},{"number":"464154","date":"2013-04-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-07-03","scope":"RELOCATE 20 SPRINKLER HEADS (17TH FLOOR, NEW COLLEGE BUILDING)"},{"number":"22554","date":"2013-09-17","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2013-09-20","scope":"09/24/2013 ERECT ASSEMBLY TENT (30'X40')FOR HANNEMANN HOSPITAL"},{"number":"493082","date":"2013-09-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-11-12","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING HOSPITAL ON THE THIRD FLOOR, ALTERATION TO INCLUDE THE DEMOLITION OF EXISTING PARTITION WALLS AND FOR THE ERECTION OF PARTITION WALLS, INSTALLATION OF MEDICAL EQUIPMENT AND PROVIDE FINISHES THROUGHOUT. STRUCUTURAL ALTERATIONS TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK."},{"number":"494249","date":"2013-09-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-11-12","scope":"FOR HVAC ALTERATION TO INCLUDE THE DEMOLITION OF EXISITNG REGISTERS AND DIFFUSER IN AREA SPECIFIED IN APPROVED PLAN. HVAC WORK TO INCLUDE THE ERECTION OF REGISTERS, DIFFUSERS, HVAC EQUIPMENT AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK."},{"number":"498078","date":"2013-10-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-11-12","scope":"3RD FLOOR - NORTH TOWER - SOUTHWEST CORNER - ANGIO BI-PLANE SUITE - INSTALL (4)NEW SINKS"},{"number":"498537","date":"2013-10-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-11-07","scope":"RELOCATE 9 SPRINKLER HEADS, 3RD FLOOR, NORTH TOWER"},{"number":"494252","date":"2013-10-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-01","scope":"INSTALL 1 BIPLANE MACHINE,2 PANELS,1 XFORMER,15 RECEPTACLES,25 FIXTURES AND 10 SWITCHES PER 2008 NEC (HEALTH CARE FACILITY)"},{"number":"503274","date":"2013-12-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-28","scope":"INSTALL (4)SMOKE DETECTORS AND (1)HORN STROBE PER THE APPROVED PLANS, 2008 NEC AND THE NFPA 72"},{"number":"511494","date":"2013-12-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"EXPIRED","completedDate":"2015-02-02","scope":"RELOCATE 84 EXISTING SPRINKLER HEADS (5TH, 14TH AND 17TH FLOORS)"},{"number":"512539","date":"2014-01-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-06-24","scope":"HVAC INSTALLATION TO NEW SLEEP STUDY CENTER AS PER PLAN."},{"number":"511771","date":"2014-01-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-06-24","scope":"LEVEL II ALTERATION TO CREATE A SLEEP STUDY CENTER AS PER PLAN."},{"number":"517453","date":"2014-01-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-06-18","scope":"RELOCATE (15) EXISTING SPRINKLER HEADS ON 14TH FLOOR-SOUTH TOWER"},{"number":"512031","date":"2014-02-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-04-12","scope":"INSTALLL 35 LLIGHTS, 65 DEVICES, AND NURSE CALL AS PER 2008 NEC (CC DISTRICT)"},{"number":"523803","date":"2014-04-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-10-07","scope":"RELOCATE 20-STROBES, 10-HORN STROBES, 21-PULL STATIONS & 10 SPEAKERS AS PER NEC 2008 & NPFA 72 (OFFICE BLDG)"},{"number":"516348","date":"2014-04-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-06-24","scope":"LEVEL 2 ALTERATION TO CREATE SLEEP STUDY CENTER AS PER PLANS (HOSPITAL)"},{"number":"541679","date":"2014-06-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-05-13","scope":"FOR LEVEL II INTERIOR ALTERATIONS TO PROVIDE ALL ACCESSIBLE FEATURES (TOILET FACILITIES, COMMON PATH ELEMENTS, WORK AREAS, ROOM UPGRADES) IN AN EXISTING HOSPITAL FACILITY. WORK TO BE DONE IN ACCORDANCE WITH APPROVAL FROM PENNSYLVANIA DEPT. OF HEALTH (ID #081701-01). **ALL ASBESTOS TO BE TREATED/REMOVED PRIOR TO COMMENCEMENT OF WORK.**"},{"number":"550435","date":"2014-07-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-01-16","scope":"PULL MELE TAPE (PULL ROPE) THROUGH AN EXISTING CONDUIT FROM THE EXISTING 1ST FLOOR TELCO ROOM UP TO THE AT&T LEASED SPACE ON THE 21ST FLOOR AS PER 2008 NEC (CC DISTRICT)"},{"number":"548047","date":"2014-07-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-08-29","scope":"RENOVATION OF EXISTING BATHROOMS TO MAKE ADA COMPLIANT PER 2008 NEC (HEALTH CARE FACILITY)"},{"number":"545990","date":"2014-08-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-11-20","scope":"RENOVATE EXISTING BATHROOMS TO MAKE THEM ADA COMPLIANT (HEALTH CARE FACILITY)"},{"number":"545979","date":"2014-09-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-05-13","scope":"FOR LEVEL II ALTERATIONS TO EXISTING MECHANICAL SYSTEM IN A HEALTH FACILITY. ALTERATION TO INCLUDE THE REMOVAL/INSTALLATION OF MECHANCIAL EQUIPMENT WITH ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR PLUMBING AND ELECTRICAL WORK."},{"number":"23191","date":"2014-10-02","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2014-10-02","scope":"09/30/2014 ERECT ASSEMBLY TENT (20'X30') HAHNEMANN UNIVERSITY HOSPITAL"},{"number":"599841","date":"2015-04-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-05-13","scope":"RELOCATE 10 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"603182","date":"2015-05-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REPLACE 33-HORN STROBES THROUGHOUT BATHROOMS AS PER NFPA 72 (HEALTH CARE FACILITY) CC DISTRICT"},{"number":"637312","date":"2015-09-08","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2015-09-08","scope":"FOR USE AS GROUP PRACTITIONER ON 12TH FLOOR OF AN EXISTING HOSPITAL COMPLEX WITH ALL OTHER USES AS PREVIOUSLY APPROVED."},{"number":"639019","date":"2015-09-16","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-12-08","scope":"INTERIOR DEMOLITION CONSISTING OF REMOVAL OF FLOORING, CEILING TILE, AND NON STRUCTURAL PARTITIONS.EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"640698","date":"2015-09-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"ELECTRICAL SAFE OFF, INSTALL TEMP 50AMP PANEL FOR TEMP ELECTRICAL AND LLIGHTIN 3 SETS OF STRIN LIGHTS IN CORRIDOR DURING DEMO FOR ONE MONTH AS PER 2008 NEC (CC DISTRICT)"},{"number":"637301","date":"2015-10-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-02-12","scope":"LEVEL II INTERIOR ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO FIT OUT A DIALYSIS UNIT ON THE 12TH FLOOR OF THE BOBST BUILDING OF AN EXISTING HOSPITAL COMPLEX AS PER APPROVED PLANS AND PA DOH APPROVALS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**"},{"number":"642736","date":"2015-10-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-02-14","scope":"INSTALLATION OF NEW MECHANICAL SYSTEM FOR NEWLY CREATED DIALYSIS UNIT ON 12TH FLOOR OF THE BOBST BUILDING OF AN EXISTING HOSPITAL COMPLEX AS PER APPROVED PLANS. SEE A/P 637301 FOR ALTERATIONS WORK"},{"number":"647362","date":"2015-10-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-02-09","scope":"RELOCATE 62 HEADS FOR THE TENANT FITOUT ON THE 12TH FLOOR"},{"number":"23832","date":"2015-10-28","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2015-10-28","scope":"PERMIT FOR THE ERECTION OF ONE TEMPORARY TENT 20 X 40"},{"number":"649343","date":"2016-01-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-08-01","scope":"ALTERATION: INTERIOR PLUMBING OF A 12TH FLOOR SPACE IN A HIGH RISE BUILDING, FOR A NEW DIALYSIS SUITE. THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004."},{"number":"648287","date":"2016-01-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL65 NEW LIGHTS, 75 RECEPTACLES. INSTALL CONDUIT FOR DATA DROPS. INSTALL ALL NEW BRANCH CIRCUIT CONDUCTORS. NEW 400 AMP MLO SECTIN WITH NEW FEEDER. NEW 225 AMP MAIN BREAKER SECTION EXIST FEEDER AS PER NEC 2008"},{"number":"657223","date":"2016-01-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-03-02","scope":"FIRE ALARM - ADD 1 NEW SMOKE HEAD AS PER NFPA 72 CC DISTRICT"},{"number":"693803","date":"2016-06-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-11-30","scope":"FOR A PARTIAL CHANGE OF OCCUPANCY W. NO CHANGE OF OCCUPANCY CLASSIFICATION TO EXTEND EXISTING EMERGENCY DEPARTMENT INTO ADJACENT SPACE & CREATION OF PATIENT TREATMENT SUITE (NON-SLEEPING AREA) & ASSOCIATED NURSE STATION INCLUDING LEVEL 2 ALTERATIONS TO INCLUDE ERECTION OF PARTITION WALLS FOR SUITE SPACE, TREATMENT ROOM & ASSOSCIATED SPACES & FINISH WORK; WORK AREA TO BE FULLY SPRINKLERED. SEPARATE PERMIT REQ'D FOR ANY MECHANICAL, ELECTRICAL, PLUMBING & FIRE SUPPRESSION WORK."},{"number":"706343","date":"2016-07-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-11-21","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"673063","date":"2016-07-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-04-12","scope":"FOR RENOVATIONS TO AN OUT PATIENT AMBULATORY DIALYSIS CLINIC ON THE 17TH/18TH FLOOR OF AN EXISTING BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"706158","date":"2016-07-20","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-11-21","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM FOR EMERGENCY DEPARTMENT EXPANSION ON THE FIRST FLOOR OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS."},{"number":"706138","date":"2016-08-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-11-21","scope":"ALTERATION: INTERIOR PLUMBING FOR ACCESSIBLE TOILET ROOM FIT-OUT RELATED TO 1ST FLOOR EMERGENCY ROOM EXPANSION, PER BP #693803 (HEALTH CARE). THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004."},{"number":"715536","date":"2016-08-17","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-11-08","scope":"EZ PERMIT RE-ROOFING- FOR THE INSTALLATION OF NEW ROOF COVERINGS ON EXITING ROOFS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"708631","date":"2016-08-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLATION OF 45 LIGHTS,25 SWITCHES,35 RECEPTACLES AND 5 SMOKES DETECTORS PER 2008 NEC (HEALTH CARE)2 PULL STATIONS,6 SPEAKER STROBES AND 4 STROBES PER NFPA 72"},{"number":"713324","date":"2016-09-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-03-31","scope":"INSTALL NEW DUCTWORK AND GRDS TO SERVE RENOVATED SPACE. INCLUDES NEW VAV BOXES AND 1 NEW AHU ."},{"number":"724142","date":"2016-09-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-04-12","scope":"RELOCATE (87) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"714651","date":"2016-09-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-04-10","scope":"ALTERATIONS TO EXISTING TENANT, NEW LIGHT FIXTURES (265) NEW ELECTRICAL DEVICES (183). TELEDATA WIRING, NURSE CALL, RELOCATE (3) PANELS, REPLACE (3) PANELS, (1) NEW PANELS AS PER 2008 NEC. (CC DISTRICT) FIRE ALARM DRAWINGS TO FOLLOW NFPA 72."},{"number":"724841","date":"2016-09-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-04-12","scope":"RELOCATE (6) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"724855","date":"2016-09-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-04-12","scope":"RELOCATE (2) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"713329","date":"2016-11-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-03-31","scope":"ALTERATIONS: INTERIOR PLUMBING; OUT-PATIENT AMBULATORY DIALYSIS CLINIC ON THE 17TH/18TH FLOOR; DIALYSIS CLINIC - NO NEW WATER HEATERS - 1-1/4\" VENTS ARE PROHIBITED BY TABLE P-1110.4 OF THE PHILADELPHIA PLUMBING CODE 2004 (1-1/2\" IS THE MINIMUM SIZE VENT)"},{"number":"738027","date":"2016-11-18","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-11-29","scope":"TCO FOR DIALYSIS CLINIC LOCATED ON 18TH FLOOR PHASE ONE"},{"number":"738551","date":"2016-11-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-02-08","scope":"RELOCATE (16) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"741813","date":"2016-12-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-06-27","scope":"RELOCATE (4) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"744111","date":"2016-12-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-03-14","scope":"INSTALL 100AMP METER AND SERVICE 1 FLUORESCENT LIGHT FIXTURE AND 4 RECEPTACLES 2008 NEC (NEWSSTAND)"},{"number":"737828","date":"2016-12-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REPLACE EXISTING IR MACHINE, INSTALL (18) NEW LIGHT FIXTURES, AND ADDITIONAL CONDUITS AS PER 2008 NEC (CC DISTRICT)"},{"number":"737139","date":"2017-01-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-10-10","scope":"LEVEL II ALTERATIONS FOR IR ROOM AS PER PLAN. **SEPARATE PERMITS REQUIRED FOR M.E.P.**"},{"number":"772414","date":"2017-05-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-10-10","scope":"FOR SELECTIVE INTERIOR DEMOLITION AND FOR LEVEL II ALTERATIONS TO UPDATE AN EXISTING MEDICAL OFFICE SPACE. WORK TO INCLUDE INTERIOR NON-BEARING PARTITIONS, MILLWORK, AND FINISHES. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND FIRE SUPPRESSION SYSTEMS. ** ALL ASBESTOS TO BE TREATED & REMOVED PRIOR TO COMMENCEMENT OF WORK. **"},{"number":"774394","date":"2017-06-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-10-10","scope":"ALTERATION: INTERIOR PLUMBING FOR THE FIT-OUT OF PATIENT TOILET & BATHROOMS, ON THE 11TH FLOOR OF THE SOUTH TOWER , IN AN EXISTING HOSPITAL. THE INSTALLATION SHALL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004."},{"number":"839325","date":"2017-12-28","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2017-12-28","scope":"FOR THE LOT ADJUSTMENT TO CREATE SIX (6) LOTS (PROPOSED PARCELS A, B, C, D, E AND F) FROM FIVE (5) OPA ACCOUNTS (200-14 N BROAD ST, 216-20 N BROAD ST, 222-48 N BROAD ST, 1417-35 RACE ST, 225-51 N 15TH ST). SIZE AND LOCATION AS SHOWN ON PLANS AND APPLICATION. **LOTS TO BE SUBSEQUENTLY JOINED BY UNITY OF USE PERMIT (A/P NO 842067-72). SUBDIVISION PERMIT SUBJECT TO REVOCATION IF UNITY OF USE IS NOT LEGALLY ESTABLISHED.** **BBS VARIANCE REQUIRED FOR NEWLY CREATED, NONCOMPLIANT CONDITION.**"},{"number":"842067","date":"2018-01-23","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2018-01-23","scope":"FOR THE CREATION OF A UNITY OF USE TO CREATE ONE (1) LOT FOR ZONING PURPOSES (TO BE KNOWN AS 222-48 N BROAD STREET) WITH RESPECTIVE COVENANTS, AGREEMENTS AND EASEMENTS TO BE RECORDED BY DEED TO BIND CURRENT AND FUTURE OWNERS OF THE CONTIGUOUS SIX (6) PARCELS (200-14 N BROAD ST, 216-20 N BROAD ST, 222-48 N BROAD ST, 201-19 N 15TH ST, 221-23 N 15TH ST, 225-51 N 15TH ST) TO PRESERVE THE UNITY OF USE AND THE LEGALITY OF THE ENTIRE PROJECT THAT STEMS FROM SINGLE ZONING LOT TREATMENT. PRIOR TO ISSUANCE OF BUILDING PERMITS AND/OR CERTIFICATION OF OCCUPANCY, PROOF RECORDATION OF EASEMENTS, AGREEMENTS AND RESTRICTIVE COVENANTS MUST BE SUPPLIED. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. PARCEL FOR USE AS HOSPITAL, GROUP MEDICAL, DENTAL AND HEALTH PRACTITIONERS OFFICE, EDUCATIONAL FACILITIES, BUILDING SERVICES, ACCESSORY PARKING, WIRELESS SERVICE FACILITY, ACCESSORY SIGNS AND BUILDING ID SIGNS. NO CHANGE OF USE ON THIS APPLICATION. SEE A/P NO 839325."},{"number":"25880","date":"2018-10-02","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2018-10-02","scope":"09/25/18 - ERECT TENT 20X40"},{"number":"ZP-2025-012637","date":"2025-12-24","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Residential - Household Living - Multi-Family"},{"number":"GM-2025-011454","date":"2026-01-28","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Issued","completedDate":null,"scope":"- For the interior demolition on NON-Load-Bearing partition walls and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. Removal of existing fire suppression systems shall not be applicable to EZ permit process No exterior work as part of this permit; interior work only; no work to exterior windows or doors(As per PHC conditions)."}],"storyTag":"Improved","storyDelta":-0.73,"timeline":[{"y":2017,"k":"permit","w":"Plumbing"},{"y":2017,"k":"insp","w":"Inspection passed"},{"y":2017,"k":"permit","w":"Zoning"},{"y":2018,"k":"sale","p":26200000},{"y":2018,"k":"permit","w":"Zoning"},{"y":2018,"k":"permit","w":"Operations"},{"y":2025,"k":"viol","w":"5 L&I violations"},{"y":2025,"k":"insp","w":"Inspection failed"},{"y":2025,"k":"sale","p":7050000},{"y":2025,"k":"permit","w":"Change of Use"},{"y":2026,"k":"permit","w":"Interior Non-Load-Bearing Wall Demo."},{"y":2026,"k":"insp","w":"Inspection failed ×2"}],"rented":false,"licenses":[{"number":"209325","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"SODEXHO MARRIOTT MGMT INC","legalName":"SODEXHO MARRIOTT MGMT INC","address":"222-48 N BROAD ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2001-05-01","latestIssueDate":"2001-05-01","expirationDate":"2002-04-30","inactiveDate":null},{"number":"205210","type":"Food Preparing and Serving","status":"Inactive","businessName":"THE BEAN BAG CAFE INC","legalName":"THE BEAN BAG CAFE INC","address":"222-48 N BROAD ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2004-06-10","latestIssueDate":"2015-05-14","expirationDate":"2016-04-30","inactiveDate":"2016-06-29"},{"number":"295030","type":"Vendor - Newsstand","status":"Inactive","businessName":"BRENDA HOUGH","legalName":"BRENDA HOUGH","address":"222-48 N BROAD ST","revenueCode":"3414","rentalCategory":null,"units":null,"issuedDate":"2004-08-24","latestIssueDate":"2014-07-18","expirationDate":"2015-03-31","inactiveDate":"2015-05-30"},{"number":"203159","type":"Food Preparing and Serving","status":"Inactive","businessName":"HAHNEMANN UNIVERSITY HOSPITAL","legalName":"HAHNEMANN UNIVERSITY HOSPITAL","address":"222-48 N BROAD ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","expirationDate":"2009-06-30","inactiveDate":null},{"number":"286111","type":"Hazardous Materials","status":"Inactive","businessName":"ALLEGHENY HEALTH ED & RESEARCH","legalName":"ALLEGHENY HEALTH ED & RESEARCH","address":"222-48 N BROAD ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","expirationDate":"2006-01-28","inactiveDate":null},{"number":"422076","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"SODEXO MANAGEMENT INC","legalName":"SODEXO MANAGEMENT INC","address":"222-48 N BROAD ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2007-08-30","latestIssueDate":"2019-04-30","expirationDate":"2020-04-30","inactiveDate":"2020-06-29"},{"number":"475827","type":"High Rise","status":"Inactive","businessName":"HAHNEMANN UNIVERSITY HOSPITAL (STEVEN MORRISSEY)","legalName":"HAHNEMANN UNIVERSITY HOSPITAL","address":"222-48 N BROAD ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2009-06-04","latestIssueDate":"2013-07-09","expirationDate":"2014-04-30","inactiveDate":null},{"number":"475864","type":"Hazardous Materials","status":"Inactive","businessName":"HAHNEMANN UNIVERSITY HOSPITAL","legalName":"HAHNEMANN UNIVERSITY HOSPITAL","address":"222-48 N BROAD ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2009-06-15","latestIssueDate":"2011-04-11","expirationDate":"2011-11-30","inactiveDate":null}],"licenseActivity":[{"number":"475864","type":"Hazardous Materials","businessName":"HAHNEMANN UNIVERSITY HOSPITAL","legalName":"HAHNEMANN UNIVERSITY HOSPITAL","issuedDate":"2009-06-15","latestIssueDate":"2011-04-11","closureDate":"2011-11-30","expirationDate":"2011-11-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"475827","type":"High Rise","businessName":"HAHNEMANN UNIVERSITY HOSPITAL (STEVEN MORRISSEY)","legalName":"HAHNEMANN UNIVERSITY HOSPITAL","issuedDate":"2009-06-04","latestIssueDate":"2013-07-09","closureDate":"2014-04-30","expirationDate":"2014-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"422076","type":"Food Preparing and Serving (30+ SEATS)","businessName":"SODEXO MANAGEMENT INC","legalName":"SODEXO MANAGEMENT INC","issuedDate":"2007-08-30","latestIssueDate":"2019-04-30","closureDate":"2020-06-29","expirationDate":"2020-04-30","inactiveDate":"2020-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"203159","type":"Food Preparing and Serving","businessName":"HAHNEMANN UNIVERSITY HOSPITAL","legalName":"HAHNEMANN UNIVERSITY HOSPITAL","issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","closureDate":"2009-06-30","expirationDate":"2009-06-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"286111","type":"Hazardous Materials","businessName":"ALLEGHENY HEALTH ED & RESEARCH","legalName":"ALLEGHENY HEALTH ED & RESEARCH","issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","closureDate":"2006-01-28","expirationDate":"2006-01-28","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"295030","type":"Vendor - Newsstand","businessName":"BRENDA HOUGH","legalName":"BRENDA HOUGH","issuedDate":"2004-08-24","latestIssueDate":"2014-07-18","closureDate":"2015-05-30","expirationDate":"2015-03-31","inactiveDate":"2015-05-30","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"205210","type":"Food Preparing and Serving","businessName":"THE BEAN BAG CAFE INC","legalName":"THE BEAN BAG CAFE INC","issuedDate":"2004-06-10","latestIssueDate":"2015-05-14","closureDate":"2016-06-29","expirationDate":"2016-04-30","inactiveDate":"2016-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"209325","type":"Food Preparing and Serving (30+ SEATS)","businessName":"SODEXHO MARRIOTT MGMT INC","legalName":"SODEXHO MARRIOTT MGMT INC","issuedDate":"2001-05-01","latestIssueDate":"2001-05-01","closureDate":"2002-04-30","expirationDate":"2002-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"record-pressure","level":"strong","title":"Records to verify together","summary":"Several independent, separately dated records stack up here and deserve prompt verification.","evidence":["5 open L&I violations","$5,859 appeared in the City's June 2022 delinquency snapshot","failed L&I inspection activity in 2025, 2026"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."},{"kind":"post-purchase-work","level":"watch","title":"Post-purchase work pattern","summary":"A recorded purchase followed by 2 permit events matches the early part of a renovate-and-resell sequence.","evidence":["purchase recorded in 2025","permit activity in 2025, 2026"],"caveat":"This does not show that the property is listed or that a sale is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #637312: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"2 permits not marked completed: 511494 (EXPIRED), GM-2025-011454 (Issued). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"5 open L&I violations","finding":"50 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"dated-tax-balance","level":"attention","title":"A dated tax balance needs a current payoff","finding":"$5,859.23 was recorded in the City’s 2022-06 delinquency snapshot for 2021.","why":"That is historical evidence, not today’s amount due. A current exemption, payment, credit, or assistance agreement can coexist with an older snapshot row.","action":"Check period balances and request a dated Property Payoff statement for settlement.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"27 failed, 13 passed, and 1 CLOSED investigation outcome are in the fetched history; the latest dated visit was FAILED on Jul 15, 2026.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"verify","title":"A fire-system permit exists, but no annual certification matched","finding":"43 fire/suppression-related permits matched; the fetched BIN certification feed returned no row.","why":"Installed systems in mixed-use and larger buildings generally require periodic certification, but applicability and limited-area exceptions vary. A missing BIN/address join is not proof of a compliance failure.","action":"Confirm what system was installed and whether a current annual certificate is required and filed.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Preparing and Serving (30+ SEATS) #209325: Inactive; Food Preparing and Serving #205210: Inactive since Jun 29, 2016; Vendor - Newsstand #295030: Inactive since May 30, 2015; Food Preparing and Serving #203159: Inactive","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as commercial. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}