{"asOf":"2026-07-28T19:58:03.476Z","block":"200-299 S 34TH ST","blockUrl":"https://philadelphia.blockreport.homes/block/200-299-s-34th-st","address":"221 S 34TH ST","parcelNumber":"773588500","source":"https://property.phila.gov/?p=773588500","ownerType":"investor","kind":"commercial","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":true,"institutional":true,"buildingCode":"VC0","buildingCodeNew":"613","buildingClass":"SCHOOL 3 STY MASONRY","buildingClassNew":"COLLEGES & UNIVERSITY","useLabel":"School","owner":"TRS UNIV OF PENN","coOwner":null,"marketValue":12207500,"landAssessment":1586975,"improvementAssessment":10620525,"livableArea":31050,"yearBuilt":1973,"lastSale":{"price":1,"date":"1993-12-16T05:00:00Z"},"openViolations":6,"violations":[{"number":"1765524","date":"2008-04-11","code":"FC-914.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1765523","date":"2008-04-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1733483","date":"2010-06-28","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2022-054716","date":"2022-07-27","code":"F-1103.5.8","title":"BUILDINGS 45 FT OR MORE IN HEIGHT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054717","date":"2022-07-27","code":"F-1103.5.8.1","title":"RETROFIT OF BUILDINGS","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054718","date":"2022-07-27","code":"F-901.6.4.2","title":"SUBMISSION OF CERTIFICATIONS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054719","date":"2022-07-27","code":"F-5303.5.3","title":"SECURING COMPRESSED CYLINDERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054720","date":"2022-07-27","code":"F-703.1","title":"PENETRATIONS MAINTAINING PROTECTION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054721","date":"2022-07-27","code":"PM15-504.3","title":"PLUMBING SYSTEMS- HAZARDS","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-099566","date":"2024-12-18","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2025-06-26","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"3075414","date":"2013-11-08","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3075412","date":"2013-11-08","code":"A-301.1/43","title":"PERMB- INSTALL DUCTWORK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3075413","date":"2013-11-08","code":"A-301.1/46","title":"PERMB- INSTALL HVAC SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5180864","date":"2019-09-13","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"155377","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2008-04-11","completedDate":"2010-10-07","violations":[{"number":"1765524","date":"2008-04-11","code":"FC-914.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1765523","date":"2008-04-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"241262","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2010-06-29","completedDate":"2010-07-29","violations":[{"number":"1733483","date":"2010-06-28","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2022-075079","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2022-07-28","completedDate":null,"violations":[{"number":"VI-2022-054716","date":"2022-07-27","code":"F-1103.5.8","title":"BUILDINGS 45 FT OR MORE IN HEIGHT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054717","date":"2022-07-27","code":"F-1103.5.8.1","title":"RETROFIT OF BUILDINGS","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054718","date":"2022-07-27","code":"F-901.6.4.2","title":"SUBMISSION OF CERTIFICATIONS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054719","date":"2022-07-27","code":"F-5303.5.3","title":"SECURING COMPRESSED CYLINDERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054720","date":"2022-07-27","code":"F-703.1","title":"PENETRATIONS MAINTAINING PROTECTION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2022-054721","date":"2022-07-27","code":"PM15-504.3","title":"PLUMBING SYSTEMS- HAZARDS","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"CF-2024-128368","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"AUDITS AND INVESTIGATIONS BUILDING CERTS","status":"CLOSED","createdDate":"2024-12-18","completedDate":"2025-06-26","violations":[{"number":"VI-2024-099566","date":"2024-12-18","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2025-06-26","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"478248","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3075414","date":"2013-11-08","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3075412","date":"2013-11-08","code":"A-301.1/43","title":"PERMB- INSTALL DUCTWORK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3075413","date":"2013-11-08","code":"A-301.1/46","title":"PERMB- INSTALL HVAC SYS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"953501","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"5180864","date":"2019-09-13","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2008,"n":2,"worst":null},{"y":2010,"n":1,"worst":null},{"y":2013,"n":3,"worst":null},{"y":2019,"n":1,"worst":null},{"y":2022,"n":6,"worst":null},{"y":2024,"n":1,"worst":null}],"investigations":[{"caseNumber":"155377","date":"2008-04-11","type":"CI INSP","status":"FAILED"},{"caseNumber":"155377","date":"2009-11-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"155377","date":"2010-01-27","type":"CI INSP","status":"FAILED"},{"caseNumber":"155377","date":"2010-02-25","type":"CI INSP","status":"FAILED"},{"caseNumber":"241262","date":"2010-06-28","type":"CI INSP","status":"FAILED"},{"caseNumber":"155377","date":"2010-07-28","type":"CI INSP","status":"FAILED"},{"caseNumber":"241262","date":"2010-07-28","type":"CI INSP","status":"PASSED"},{"caseNumber":"155377","date":"2010-10-06","type":"CI INSP","status":"PASSED"},{"caseNumber":"CF-2022-075079","date":"2022-07-28","type":null,"status":"FAILED"},{"caseNumber":"CF-2022-075079","date":"2023-09-12","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-128368","date":"2025-03-31","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-128368","date":"2025-05-23","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-128368","date":"2025-06-26","type":null,"status":"PASSED"}],"inspYears":[{"y":2008,"fails":1,"passes":0},{"y":2009,"fails":1,"passes":0},{"y":2010,"fails":4,"passes":2},{"y":2022,"fails":1,"passes":0},{"y":2023,"fails":1,"passes":0},{"y":2025,"fails":2,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.950815620087944,"lng":-75.19216035381596,"geom":{"type":"Polygon","coordinates":[[[-75.19247096,39.950543117],[-75.192349902,39.951124934],[-75.191826306,39.951060401],[-75.191903306,39.950690349],[-75.191991645,39.950701237],[-75.192035709,39.950489472],[-75.19247096,39.950543117]]]},"liDistrict":"CENTRAL WEST","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19104","beds":null,"baths":null,"stories":null,"lotArea":31908,"zoning":"SPINS","grade":"A","basement":null,"heater":null,"centralAir":null,"extCond":"3","intCond":"3","garage":null,"homestead":false,"mail":"3451 WALNUT ST, PHILADELPHIA PA, 19104","mailOut":false,"appeals":[{"type":"Building standards appeal","grounds":"ON 01/08/16, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #631874.","status":"CLOSED","outcome":"APPROVED","date":"2016-02-16","number":"26886","relatedPermit":"644674"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":11451200,"taxable":0,"land":319100,"improvement":11132100,"taxableLand":0,"taxableImprovement":0,"exemptLand":319100,"exemptImprovement":11132100},{"y":2017,"v":11451200,"taxable":0,"land":319100,"improvement":11132100,"taxableLand":0,"taxableImprovement":0,"exemptLand":319100,"exemptImprovement":11132100},{"y":2018,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2019,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2020,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2021,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2022,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2023,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2024,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2025,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2026,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525},{"y":2027,"v":12207500,"taxable":0,"land":1586975,"improvement":10620525,"taxableLand":0,"taxableImprovement":0,"exemptLand":1586975,"exemptImprovement":10620525}],"taxNow":0,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"63160","date":"2007-03-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-08-08","scope":"ALTERATIONS TO 3RD FLR. LABS"},{"number":"73507","date":"2007-05-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":null,"scope":"(O)SK IW"},{"number":"74128","date":"2007-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-27","scope":"INSTALL WIRING FOR RENOVATED LABS CONSISTING OF NEW LIGHTING, POWER FOR LAB EQUIPMENT, 3 NEW PANELS, AND FIRE ALARM WORK . THIS WORK ALSO INCLUDES POWER AND LIGHTING FOR CORRIDOR, 2 OFFICES AND BREAKROOM (CC DIST)"},{"number":"140226","date":"2008-05-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-06-29","scope":"INTERIOR ALTERATIONS"},{"number":"158832","date":"2008-07-16","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2008-07-16","scope":"FOR THE PARTIAL DEMOLITION OF AN EXISTING 1+2 STORY STRUCTURE, THE DEMOLITION OF A 1-STORY LINK, THE COMPLETE DEMOLITION OF A 2-STORY STRUCTURE AND FOR THE ERECTION OF A THREE (3) STORY ADDITION WITH A CELLAR. SIZE AND LOCATION AS SHOWN IN THE APPLICATION. THREE (3) STORY ADDITION FOR USE AS EXTENSION OF AN EXISTING MUSIC SCHOOL WITH CLASSROOMS, OFFICES, RECORDING STUDIO, LOUNGES, OFFICES AND OTHER SCHOOL USES ON THE SAME UNITY OF USE LOT WITH 13 OTHER STRUCTURES AS PART OF A UNIVERSITY COMPLEX."},{"number":"160909","date":"2008-07-16","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2008-07-16","scope":"FOR A UNITY OF USE TO CREATE ONE (1) LOT FROM THREE (3) LOTS FOR ZONING PURPOSES."},{"number":"168157","date":"2008-08-22","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2010-06-28","scope":"ERECT 3 STY. ADDITION PER SUBMITTED SEALED PLANS. C.O."},{"number":"170776","date":"2008-09-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-02-05","scope":"ALTS. & DEMO. TO EXISTING BUILDINGS PER SUBMITTED SEALED PLANS."},{"number":"189130","date":"2008-11-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-07-01","scope":"FIXTURE INSTALLATION IN ADDITION"},{"number":"191532","date":"2008-12-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-04-07","scope":"INSTALL FOUR NEW FIXTURES: 2 LAVATORIES, 2 WATER CLOSETS..."},{"number":"191414","date":"2008-12-30","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-04-07","scope":"INSTALL DUCTWORK AND NEW REGISTERS AND DIFFUSERS WITHIN THE 5TH FLOOR SICU WAITING ROOM AREA OF AN EXISTING HOSPITAL AS PER PLANS."},{"number":"187067","date":"2009-01-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-11-21","scope":"NEW 400A SERVICE, LIGHTING, BRANCH CIRCUITS & CONDUITS SLEAVES FOR TELE/DATA."},{"number":"196648","date":"2009-02-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-11-21","scope":"AMENDMENT FOR PERMIT # 187067 TO ADD FIRE ALARM SYSTEM."},{"number":"199710","date":"2009-02-19","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2009-02-19","scope":"FOR THE ERECTION OF A ONE (1) STORY ADDITION (VESTIBULE ENTRY) AND FOR THE ERECTION OF ROOF TOP MECHANICAL EQUIPMENT TO INCLUDE A STEEL PLATFORM. SIZE AND LOCATION AS SHOWN IN THE APPLICATION. VESTIBULE ENTRY AND ROOF TOP MECHANICALS AS PART OF AN EXISTING CHEMISTRY LAB STRUCTURE ALL AS PART OF AN EXISTING UNIVERSITY COMPLEX."},{"number":"196563","date":"2009-03-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-09-11","scope":"ALTERATIONS TO CHEMISTRY LABS"},{"number":"206651","date":"2009-04-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-09-11","scope":"INSTALL FIXTURES AND WATER HEATER"},{"number":"207769","date":"2009-04-16","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2010-09-03","scope":"CONSTRUCTION OF EGRESS NEW VESITBULE, ACCESSORY EXTERIOR FACADE REMOVAL AND REPLACEMENT WITH CURTAIN WALL SYSTEM TO MATCH, ACCESSORY SITE IMPROVEMENTS AND LANDSCAPE DEMO WORK, AS PER SUBMITTED PLANS."},{"number":"212299","date":"2009-04-23","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-10-26","scope":"INSTALL 1 KITCHEN SINK"},{"number":"205066","date":"2009-04-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION OF NEW LABORATORY INCLUDING NEW PANELS, FEEDERS, RECEPTS, WIRE MOLD, LIGHTING, VOICE/DATA, NEW LAB EQUIPMENT AS PER 2005 NEC (WEST DISTRICT) FIRE ALARM WORK TO FOLLOW UNDER SEPARATE PERMIT"},{"number":"207208","date":"2009-05-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-09-11","scope":"INSTALL AC SYSTEM IN BASEMENT TO SERVICE 1ST FLOOR AREA. INSTALL EXHAUST SYSTEM FOR 1ST FLOOR LAB. INSTALL HEAT RECOVERY SYSTEM ON ROOF AS PER PLANS."},{"number":"216037","date":"2009-06-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-09-11","scope":"EXTEND EXISTING SPRINKLER SYSTEM AS PER PLANS."},{"number":"211211","date":"2009-06-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-08-20","scope":"DEMO INT BASEMENT SPRINKLIERS & INSTALL NEW SPRINKLER SYS THROUGHT & INSTALL 2 STANDPIPES"},{"number":"218252","date":"2009-06-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-02","scope":"PROVIDE UNISTRUT SKIDS TO ACCOMODATE VARIOUS SPEAKER ARRAYS & ASSOCIATED ELECTRONIC EQUIPMENT FOR A CAMPUS WIDE ALERT SYSTEM.PROVIDE 120V POWER OR SOLAR PANELS AS INDICATED.PROVIDE MECHANICAL EQUIPMENT AS NEEDED. 13 AP'S 1 SET OF PLANS SEE AP 217173"},{"number":"213236","date":"2009-06-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLATION OF ADDITIONAL FIRE ALARM DEVICES PER PLANS."},{"number":"222984","date":"2009-07-01","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-02-19","scope":"INTERIOR ALTERATIONS AS PER PLANS."},{"number":"226773","date":"2009-07-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-02-25","scope":"EXTERIOR RENOVATIONS AS PER PLANS AND PHC STAFF TO REVIEW SAMPLES IN FIELD, BRICK, TERRACOTTA, BLUESTONE."},{"number":"226089","date":"2009-07-31","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-01-11","scope":"NEW SPRINKLER SYSTEM THROUGHOUT THE GROUND FLOOR, SECOND AND THIRD FLOORS, NEW BACKFLOW PREVENTION SYSTEM AND NEW STANDPIPES AS PER PLANS AND NFPA STANDARDS."},{"number":"231236","date":"2009-09-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-09-15","scope":"HVAC ALTERATIONS AS PER PLANS"},{"number":"240072","date":"2009-10-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-28","scope":"INSTALLATION OF NEW HVAC SYSTEM AND ACCESSORY MECHANICALS FOR NEW FIT OUT AND ALTERATIONS, AS PER SUBMITTED PLANS. NO PIPING/MECHANICAL PENETRATIONS PERMITTED THRU ANY RATED STAIR ENCLOSURES."},{"number":"239254","date":"2009-11-06","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-07-01","scope":"INSTALLTION OF A WET SPRINKLER SYSTEM ON LOWER LEVEL AND A DRY SYSTEM IN ATTIC"},{"number":"250740","date":"2009-12-02","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2009-12-02","scope":"TCO FOR MUSIC BUILDING PARENT PERMIT AP# 170776; 168157."},{"number":"259182","date":"2010-02-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-09-14","scope":"INTERIOR ALTERATIONS AS PER PLANS."},{"number":"273288","date":"2010-05-05","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-09-15","scope":"INTERIOR ALTERATIONS 3 WC,4 LAVS, 1 EWC, 4 FD, 13 SINKS, 24 CUP SINKS"},{"number":"272209","date":"2010-05-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-02-16","scope":"ALTERATIONS TO EXISTING DUCTWORK."},{"number":"284401","date":"2010-07-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"NEW LIGHTING AND POWER FOR A COMPLETE RENOVATION TO LABS AND RESTROOMS AS PER 2008 NEC (WEST DIST). FIRE ALARM DEVICES AS SHOWN OF FIRE ALARM DRAWINGS PER NFPA-72 (WEST DIST)"},{"number":"291151","date":"2010-07-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-09-20","scope":"ALTERATIONS TO FACILITATE PER PLAN."},{"number":"293067","date":"2010-08-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-02-16","scope":"INTERIOR ALTERATIONS AS PER PLANS"},{"number":"287204","date":"2010-08-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-18","scope":"DEMO/REMOVAL OF OLD 2400V SERVICES,DEMO,REMOVAL/UPGRADE OF EXISTING 15KV EQUIP,TRANSFORMERS,480V/208V DISTRIBUTION EQUIP,RELOCATION OF FACP TO ADJ WALL,TO ACCOMMODATE NEW ELEC RM LAYOUT, ALL WORK IN ACCORDANCE W/2008 NEC/NFPA-72(WEST DIST)"},{"number":"279190","date":"2010-09-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-10-07","scope":"CONNECT INTO EXISTING SPRINKLER MAIN AND FURNISH AND INSTALL WET SPRINKLER PROTECTION INSIDE"},{"number":"307819","date":"2010-11-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-12-30","scope":"ALTERATIONS AS SHOWN ON PLANS FOR UNIVERSITY COMPLEX."},{"number":"311299","date":"2010-11-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-12-30","scope":"REMOVE AND REPLACE TWO (2) SINKS"},{"number":"315071","date":"2010-12-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-02-18","scope":"INSTALL LIGHTING, RECEPTACLES, STARTERS & FIRE ALARM PER PLANS."},{"number":"320370","date":"2011-02-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-02-25","scope":"INSTALLATION OF DUCTWORK AND RELATED UPGRADES TO MECHANICALS"},{"number":"332443","date":"2011-04-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-11-03","scope":"ALTERATIONS AS PER PLANS FOR UNIVERSITY COMPLEX."},{"number":"336473","date":"2011-05-27","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"DISCONNECT POWER TO 38 MOTORS, REPLACE (3) VFDS AND (2) STARTERS, PROVIDE POWER TO (1) HVAC UNIT, AS PER SUBMITTED ELECTRICAL DRAWINGS, AS PER 2008 NEC (WEST DIST)"},{"number":"346120","date":"2011-06-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-10-06","scope":"INTERIOR ALTERATIONS, ADA BATHROOM UPGRADES, NEW FINISHES, FIXTURES, AS INDICATED PER PLANS. EXISTING UNIVERSITY NO CHANGE IN USES, LEVEL 2 ALTS."},{"number":"348612","date":"2011-07-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"DEMO EXISTING SINKS AND CUP SINKS, REPIPE NEW SINKS AND CUP SINKS TO NEW CASEWORK"},{"number":"347828","date":"2011-07-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"INSTALL HVAC SHEETMETAL DUCTWORK FOR UNIVERSITY COMPLEX."},{"number":"355103","date":"2011-07-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"RELOCATE 19 HEADS TO FIT NEW WALL AND CEILING LAYOUT"},{"number":"348125","date":"2011-08-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-11-30","scope":"DEMO EXISTING LIGHTING/POWER, FURNISH NEW LIGHTING/WIREMOLD RACEWAY PER PLANS,REPLACE (1) EXISTING PANEL PER PLANS (EXISTING FEEDER TO BE REFUSED),ADD (1) F/S STROBE/(1) HORN STROBE TO EXISTING SYSTEM PER PLANS,TIE IN NEW EXHAUST FANS TO EXISTING STARTERS AS PER 2008 NEC/NFPA-72"},{"number":"378622","date":"2011-12-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"DEMO EXISTING LIGHTS AND POWER. FURNISH NEW LIGHTING AND WIREMOLD RACEWAT. REPLACE TELE/DATA STUBS AS PER 2008 NEC. ***CABLE AND TERMINATIONS TO BE DONE BY OTHERS***(UNIVERSITY OF PENN CHEMISTRY LAB 3RD FLOOR)(CC DIST)"},{"number":"379839","date":"2011-12-21","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-02-13","scope":"RELOCATION OF SPRINKLER HEADS."},{"number":"360250","date":"2011-12-21","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-02-07","scope":"INSTALLATION OF FIRE SPRINKLERS IN RENOVATED CLASSROOMS, OFFICES, AND LABORATORIES."},{"number":"376873","date":"2011-12-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-02-20","scope":"INTERIOR ALTERATIONS AS PER PLANS FOR EXISTING OFFICES. NO CHANGE IN USE/OCCUPANCY."},{"number":"377447","date":"2012-01-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-02-13","scope":"REO EXISTING CHEMISTRY WITH 2 NEW SUPPLY LAMINAR DIIFUSERS, 2 EXHAUST GRILLES WITH NEW EXHAUST DUCTS AND CONNECTION TO 2 NEW HOODS."},{"number":"377454","date":"2012-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-02-13","scope":"RENOVATE EXISTING CHEMISTRY LABS WITH NEW CASEWORK. PROVIDE HOT AND COLD WATER SANITARY AND VENT PIPING TO NEW SINKS AND FAUCETS PROVIDED BY OTHERS.(UNIVERSITY OF PENN)"},{"number":"403525","date":"2012-05-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-08-09","scope":"CLASSROOMS AND OFFICES ALTERATIONS PER PLANS."},{"number":"406247","date":"2012-05-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-03","scope":"REWIRE 2 EXISTING METERS AS PER 2008 NEC(SCHOOL)(WEST DIST)"},{"number":"413124","date":"2012-06-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-08-09","scope":"RELOCATE 8 SPRINKLER HEADS"},{"number":"414980","date":"2012-08-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-09","scope":"MODIFYING & UPGRADE EXISTING HVAC SYSTEM TO ACCOMONDATE RENOVATED AREA TO INCLUDE INSTALLATION OF ONE (1) NEW VAV BOX AND FIVE (5) NEW GRDS AND ALL ASSOCIATED RETURN/EXHAUST DUCTWORK."},{"number":"420122","date":"2012-08-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-08-23","scope":"PROVIDE COLE WATER LINE TO A COFFE MACHINE AND WATER COOLER(U OF P-FISHER BENNETT HALL)"},{"number":"413437","date":"2012-08-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-10-16","scope":"INSTALL 13-DUPLEX 2-GRI 3-QUAD RECPTS 7- TELE DATA ROUGH IN 6-SWITCHES 3-WALL SENSORS 4-LIGHTS 9-RELOCATE F/A DEVICES PER 2008 NEC"},{"number":"401383","date":"2012-08-29","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-05-16","scope":"FACADE REPAIRS AS SHOWN ON PLANS. SEPARATE PERMIT REQUIRED FOR SHELTER PLATFORM."},{"number":"424460","date":"2012-09-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 110V POWER TO NEW FIRE ALARM MONITORING SYSTEM/POWER ONLY TCP/1P ETHERNET CONNECTION BY OTHERS;POWER FROM EXISTING OUTLETS AS PER 2008 NEC AND NFPA72 (SCHOOL)"},{"number":"459418","date":"2013-05-01","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-02-11","scope":"FOR INTERIOR DEMOLITION OF EXISTING INTERIOR FINISHES & LIGHTING & FOR THE INSTALLATION OF PERMANENTLY AFFIXED WORK SURFACES, & INTERIOR PARTITION WALL FOR LABORATORY SPACES; BUILDING IS FULLY SPRINKLERED. ASBESTOS ABATEMENT TO BE COMPLETED PRIOR TO COMMENCEMENT OF PERMITTED WORK."},{"number":"474264","date":"2013-06-03","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-09-27","scope":"REMOVE AND REPLACE (4) SINKS WITH NEW FAUCETS"},{"number":"469970","date":"2013-06-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-08-22","scope":"FOR THE ERECTION OF A SHELTER PLATFORMS AND FACADE REPAIRS. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS."},{"number":"475381","date":"2013-07-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-10-07","scope":"DEMO EXISTING ELECTRICAL - NEW WIRING AND RECEPTACLE DEVICES - NEW LIGHTING - 9 NEW F2 AND F12 FIXTURES - PROVIDE POWER FEEDS OT AL NEW EQUIPMENT - AS PER 2008 NEC"},{"number":"478248","date":"2013-07-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"FOR INTERIOR DEMOLITION OF EXISTING INTERIOR FINISHES AND FOR THE INSTALLATION OF WORK SURFACES FOR DRY LAB AND INTERIOR PARTITION WALL FOR OFFICE AS PER APPROVED PLANS. ABATEMENT OF ASBESTOS REQUIRED PRIOR TO COMMENCEMENT OF WORK."},{"number":"482526","date":"2013-07-31","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2013-07-31","scope":"FOR THE ERECTION OF THREE (3) FLATWALL SIGNS, SIZE AND LOCATION AS SHOWN IN APPLICATION. SIGNS ACCESSORY TO AN EXISTING EDUCATIONAL FACILITY."},{"number":"491725","date":"2013-09-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-11-13","scope":"F&I (2)800AMP DISTRIBUTION PANELS & FEEDERS (1)400 AMP PANEL & FEEDERS (1)125A PANEL (1)100A PANEL (1)30 KVA XFMR & BRANCH WIRING TO NEW HVAC UNITS FA F&I NEW VESDA DUCT DETECTORS TIED TO EXISTING FA SYSTEM PER 2008 NEC & NFPA 72 (UNIVERSITY)"},{"number":"491037","date":"2013-09-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"ALTERATIONS IN SUPPORT OF MECHANICAL UPGRADES."},{"number":"490697","date":"2013-09-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-04-23","scope":"INSTALL 120LF AI SERIES 480 RACEWAY, 48-20AMP 120V RECPT, 8-20A 120 V GFCI RECPT, 3-120V 2A SINGLE SW & RELOCATE 3-EXIST LGT FIXTURES, INSTALL BACKBOX & CONDUIT STUBS NEW & EXIST SEC DEVICE AS PER NEC 2008 (OFFICE)"},{"number":"496041","date":"2013-09-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-01-15","scope":"REPLACING 4-FLOOR DRAINS (UNIVERSITY BLDG)"},{"number":"496050","date":"2013-10-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-02-27","scope":"FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM WITH THE REPLACEMENT OF REFIGERANT PIPING, DUCTWORK, VARIABLE AIR VALVES, HEATING COILS, AIR HANDLING UNITS, AND REGISTERS/DIFFUSERS."},{"number":"498790","date":"2013-10-24","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2013-10-24","scope":"FOR THE ERECTION OF A SCREEN WALL ON THE ROOF OF AN EXISTING STRUCTURE (BUILDING D7). SIZE AND LOCATION AS SHOWN PER APPROVED PLANS."},{"number":"476572","date":"2013-10-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-02-11","scope":"PARTIAL DEMOLITION OF EXISTING EQUIPMENT AND PIPING; INSTALLATION OF NEW SUPPLY / EXHAUST AIR VALVES, DUCTWORK, REGISTERS AND DIFFUSERS PER PLANS. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL AND PLUMBING WORK. ASBESTOS ABATEMENT REQUIRED PER BUILDING PERMIT # 459418."},{"number":"513240","date":"2013-12-27","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-01-31","scope":"CONNECT TO EXISTING SANITARY & WATER PIPING FOR 4 NEW SINKS (UNIVERSITY)"},{"number":"511737","date":"2014-01-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"FOR INTERIOR DEMOLITION & FOR PRESCRIPTIVE ALTERATIONS FOR THE INSTALLATION OF PERMANENTLY AFFIXED WORK SURFACES & INFILL OF EXIT RATED WALLS FOR LABORATORY SPACES; BUILDING IS FULLY SPRINKLERED. ASBESTOS ABATEMENT TO BE COMPLETED PRIOR TO COMMENCEMENT OF PERMITTED WORK. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, & FIRE SUPPRESSION WORK."},{"number":"511142","date":"2014-01-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-03-13","scope":"FOR THE ERECTION OF A SCREEN WALL ON ROOF AS PER APPROVED PLANS."},{"number":"513224","date":"2014-02-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-02-11","scope":"INTERIOR DEMO OF EXISTING DUCT WORK, INSTALL NEW DUCTWORK, DIFFUSERS, CONNECT TO EXISTING DUCTWORK AND SYSTEM FOR NEW RECONFIGURATION OF FLOOR SPACE."},{"number":"518071","date":"2014-02-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-02-03","scope":"5TH FLOOR PLUMBING ALTERATIONS, CHEM LAB 1973 WING SCHOOL OF ARTS & SCIENCES - (2)4\" FLOOR DRAINS, (3)EMERGENCY EYE WASH/SHOWER, (3)SINKS AND (7)CUP SINKS - WORK WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004 4TH PRINTING"},{"number":"516734","date":"2014-02-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-13","scope":"PROVIDE 3 PANELS AND FEEDERS,WIRE MOLD,RECEPTACLES,TELE DATA RACEWAY,GROUNDING AND PROVIDE POWER WIRING FOR EQUIPMENT. EXCLUDES SECURITY ALARM,TELEPHONE,FA,DATA,SOUND PAGING AND LOW VOLT WIRING IN ITS ENTIRETY PER 2008 NEC (UNIVERSITY)"},{"number":"517447","date":"2014-03-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"EXPIRED","completedDate":null,"scope":"FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM WITH THE INSTALLATION AND RELOCATION OF PIPING, DUCTWORK, AIR VALVES, HEATING COILS, AND REGISTERS/DIFFUSERS AS SHOWN ON APPROVED PLANS."},{"number":"529266","date":"2014-04-08","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-04-30","scope":"FOR AN AMENDMENT OF PERMIT# 511737, ISSUED FOR ALTERATIONS WITHIN EXIST. LABORATORY BUILDING, TO CORRECT PREVIOUS PERMIT LANGUAGE TO ACCURATELY REFLECT EXISTING BUILDING AS PARTIALLY SPRINKLERED W. PREVIOUSLY APPROVED WORK AREA TO BE FULLY SPRINKLERED."},{"number":"523567","date":"2014-04-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-11-10","scope":"INSTALLATION OF CROSS MAIN AND BRANCH LINES IN A PORTION OF THE FIFTH FLOOR; MAIN SHALL BE CAPPED AT EACH END (FOR FUTURE TIE-IN) AND ALL OUTLETS TO BE PLUGGED. SEPARATE FIRE SUPPRESSION PERMIT REQUIRED FOR INSTALLATION OF SPRINKLER HEADS AND TO PLACE SYSTEM IN SERVICE; ACTIVE SPRINKLER SYSTEM REQUIRED AT WORK AREA PER ALTERATIONS PERMIT # 511737."},{"number":"524496","date":"2014-04-30","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2014-07-16","scope":"INSTALLATION OF 3 FLATWALL SIGNS ACCESSORY TO SCHOOL. SIGNS TO BE IN SIZED AND LOCATED ACCORDANCE WITH ZONING PERMIT 482526"},{"number":"530148","date":"2014-05-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-03-10","scope":"ALTERATIONS AS PER PLANS."},{"number":"549687","date":"2014-08-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-01-12","scope":"ERECTION OF A ROOFTOP DUNNAGE AND RELATED WORK TO SUPPORT MECHANICAL EQUIPMENT AS PER APPROVED PLANS. **SEPARATE MECHANICAL PERMIT REQUIRED FOR EQUIPMENT INSTALLATION**"},{"number":"561023","date":"2014-09-24","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-05-20","scope":"LEVEL II ALTERATIONS AS PER PLANS"},{"number":"562645","date":"2014-10-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-02-18","scope":"ALTERATIONS AS PER PLANS."},{"number":"575251","date":"2014-11-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-09-25","scope":"DEMO OLD PLUMBING AND REPLACE 2 SINKS (UNIVERSITY COMPLEX)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"571203","date":"2014-12-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (1)3 SECTION PANEL BOARD,78 DUPLEX RECEPTACLES,12 LIGHTS,5 SWITCHES AND 2 EMERGENCY BATTERY PACKS PER 2008 NEC (UNIVERSITY COMPLEX)"},{"number":"577488","date":"2014-12-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-03-18","scope":"REMOVE 2 SINKS REINSTALL 2 NEW SINKS ADD 1 FLOOR DRAIN (UNIVERSITY COMPLEX)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"573731","date":"2014-12-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-01-21","scope":"F&I 1-NEW 175A BREAKER, FEEDER CONDUIT, 2-PNL BOARDS, WIRE DEVICES SW, OCCP SENSORS, WIREMOLD REWAYS & TELE/DATA BOX STUBS, TELE/DATA WIRE & EQUIP BY OTHER & F/A SYS WITH 2-HORN/STROBE & 1-NAC AS PER NEC 2008 & NFPA 72"},{"number":"575718","date":"2014-12-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-03-26","scope":"INSTALL DUCTWORK AND MECHANICALS"},{"number":"587150","date":"2015-02-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 6 HORN STROBES,1 HEAT DETECTOR,1 NAC PANEL,2 DOOR HOLDERS AND 1 CONTROL MODULE PER NFPA 72 (RESEARCH BLDG)"},{"number":"592943","date":"2015-03-20","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2022-10-24","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING SECOND FLOOR OFFICES AND LABS AS PER APPROVED PLANS. EXISTING BUILDING PARTIALLY SPRINKLERED. ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**"},{"number":"598327","date":"2015-03-25","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-06-25","scope":"REPLACING 3 SINKS TO UPGRADE LAB ROOM 212-THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"597995","date":"2015-04-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-07-22","scope":"INSTALLATION OF DUCTWORK WITH ASSOCIATED REGISTERS AND DIFFUSERS, PHOENIX SUPPLY AND EXHAUST VALVES WITH ASSOCIATED SERVICE PIPING, SPOT EXHAUST, CAP AND SEAL SUPPLY GRILLE, AND REBALANCE OTHER PORTIONS OF EXISTING SYSTEM TO REMAIN PER PLANS AS PART OF LABORATORY RENOVATION. SEPARATE PERMITS REQUIRED FOR ALL ELECTRICAL AND PLUMBING WORK."},{"number":"602810","date":"2015-05-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"CHEMISTRY LAB 2ND FLOOR 1973 WING ELECTRICAL ALTERATIONS - FURNISH AND INSTALL (3)STROBES & (4)AUDIO/VIDEO DEVICES & (1)NAC PANEL PER THE APPROVED PLANS - THE INSTALLATION WILL COMPLY WITH THE 2008 NEC AND THE NFPA 72"},{"number":"609873","date":"2015-06-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-08-28","scope":"INTERIOR DEMO & ALTERATIONS, FINISHES AS PER PLANS."},{"number":"617150","date":"2015-06-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-11-19","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"621349","date":"2015-06-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"PROVIDE GENERAL RECEPTACLES AND PLUG MOLD,REUSE EXISTING BRANCH CIRCUIT WIRING.RELOCATE FUME HOODS PER 2008 NEC (UNIVERSITY COMPLEX)"},{"number":"620755","date":"2015-07-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"EXPIRED","completedDate":null,"scope":"FOR THE DEMOLITION OF EXISTING MECHANICAL EQUIPMENT AND FOR THE INSTALLATION OF DUCTWORK, REGISTERS, DIFFUSERS AND EXHAUST HOODS/FANS. ALL WORK PER APPROVED PLANS. ALL WORK IN LABS 3170 AND 3180."},{"number":"619883","date":"2015-07-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"EXPIRED","completedDate":null,"scope":"3RD FL VAGELOS LABORATORIES 3170 & 3180 - INSTALL (8)CUP SINKS, WASTE & DOMESTIC WATER PIPING - NOTE: FUEL GAS, VACUUM & SPECIALTY GAS PIPING ARE NOT PART OF THIS PERMIT - THE INSTALLATION WILL BE IN COMPLIANCE WITH THE PHILA PLUMBING CODE 2004"},{"number":"621263","date":"2015-07-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-02-03","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM FOR EDUCATIONAL FACILITY TO INCLUDE DUCTWORK AND (14) REGISTERS/DIFFUSERS AS PER APPROVED PLANS."},{"number":"621277","date":"2015-08-18","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-05-13","scope":"SUPPLY NEW LIGHTING & CONTROLS, INSTALL NEW OUTLETS AS PER NEC 2008 WEST DISTRICT & FIRE ALARM AS PER NFPA 72 FIRE ALARM AS PER NFPA 72"},{"number":"657644","date":"2015-12-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-08-12","scope":"REMOVE AND REPLACE 8- WATER CLOSETS AND 6- LAVATORIES"},{"number":"653892","date":"2015-12-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-20","scope":"REPLACE LIGHTS AND OUTLET PER 2008 NEC (UNIVERSITY COMPLEX)WEST DISTRICT"},{"number":"644674","date":"2016-04-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-08-12","scope":"NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS TO THE EXISTING RESTROOMS AND REDUCTION IN FIXTURE COUNT IN THE BASEMENT, 2ND FLOOR, AND 3RD FLOOR AS PER APPROVED PLANS AND BBS VARIANCE CASE 26886. THIS PERMIT TO INCLUDE MINOR EXTERIOR WORK. SEPARATE PERMIT REQUIRED FOR ANY MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK."},{"number":"653180","date":"2016-04-20","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-02","scope":"HVAC, TO INCLUDE DUCTWORK, FOR TOILET ROOM RENOVATIONS, AS PER PLANS. (6) REGISTERS/DIFFUSERS."},{"number":"768692","date":"2017-04-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-07-17","scope":"INTERIOR LEVEL 2 ALTERATIONS TO EXISTING STRUCTURE AS PER PLANS. NO CHANGE OF USE PROPOSED. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"773364","date":"2017-04-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"1 LAV SINK"},{"number":"774514","date":"2017-04-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-06-02","scope":"RELOCATE 1 EXISTING SPRINKLER HEAD (COMMERCIAL)"},{"number":"773501","date":"2017-05-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION TO EXISTING SPACE.INSTALL 11 LIGHT FIXTURES,9 LIGHT SWITCHES,34 RECEPTACLES AND 2 HVAC POWER PER 2008 NEC (EDUCATIONAL FACILITY)"},{"number":"773363","date":"2017-05-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"FOR THE REPLACEMENT/INSTALLATION OF REGISTER, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK TO AN EXISTING EDUCATION FACILITY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"778036","date":"2017-05-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-03-28","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING CLASSROOM ON THE FOURTH FLOOR LEVEL OF AN EXISTING EDUCATION FACILITY. ALTERATIONS TO INCLUDE THE INSTALLATION OF FINISHES, FURNISHES AND APPLIANCES THROUGHOUT. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK."},{"number":"787092","date":"2017-05-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"ONE FOR ONE REPLACEMENT OF 1-LAV SINK ONLY WITH NO ADDITIONAL PIPING.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004"},{"number":"779118","date":"2017-05-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FIRE ALARM: INSTALL 1 HORN/STROBE AS PER NFPA 72 WEST DISTRICT"},{"number":"796113","date":"2017-06-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-02-28","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"790359","date":"2017-07-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-16","scope":"SLIGHT RECONFIGURATION OF DUCTWORK TO FIT NEW LAYOUT OF LAB SPACE"},{"number":"790355","date":"2017-07-14","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Issued","completedDate":null,"scope":"TO RECONFIGURE DUCTWORK IN EXISTING SPACE WITH NEW REGISTERS/DIFFUSERS AND ASSOCIATED NEW DUCTWORK, AS PER APPROVED PLANS."},{"number":"790365","date":"2017-07-14","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-03-28","scope":"ALTERATION: INTERIOR PLUMBING;UNIVERSITY OF PENN COMPLEX.4TH FLOOR CLASSROOOM;EDUCATIONAL FACILITY - THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004"},{"number":"792109","date":"2017-07-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-14","scope":"REMOVE EXISTING WIREMOLD,DEVICES AND FIXTURES,EXISTING CIRCUITS REMAIN.INSTALL 8 NEW LIGHTS FIXTURES AND CIRCUIT TO EXISTING SWITCHES AND INSTALL NEW RECEPTACLES IN CONFERENCE ROOM PER 2008 NEC (UNIVERSITY COMPLEX)"},{"number":"792108","date":"2017-08-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-02","scope":"DEMO & INSTALL 28 FIXTURES AND EXISTING CONTROLS PROVIDE NEW WIRING.DEMO 7 EXISTING 125AMP BRANCH AND FURNISH 4 NEW PANELS AND BRANCH WIRING.INSTALL NEW FIXTURES,RECEPTACLES AND BRANCH WIRING PER 2008 NEC (UNIVERSITY COMPLEX)INSTALL 4 HORN/STROBES,1 FLOW SWS & TAMPER SWS AND EXTEND WIRING TO EXISTING LOOP PER NFPA 72"},{"number":"827382","date":"2017-11-07","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"LEVEL II ALTERATIONS TO EXISTING STRUCTURE AS PER PLANS. NO CHANGE OF USE PROPOSED. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, AND FIRE SUPPRESSION WORK."},{"number":"833356","date":"2017-12-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-11","scope":"FOR MECHANICAL ALTERATIONS TO EXISTING SPACE (HAYDEN HALL- ROOM 371) TO INCLUDE REROUTING OF EXISTING DUCTWORK AND INSTALLATION OF NEW REGISTERS/DIFFUERS, AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR PLUMBING WORK."},{"number":"840329","date":"2018-01-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-05-02","scope":"INTERIOR ALTERATION TO RECONFIGURE 3RD FLOOR SPACE 325 WITHIN THE CHEMISTRY 1973 WING - CREATE NEW PARTITIONS/DOORS AS PER PLANS. ASBESTOS REMOVAL NECESSARY PRIOR TO DEMO/RENOVATION."},{"number":"835923","date":"2018-01-10","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2018-01-10","scope":"FOR THE ERECTION OF EXTERIOR ACCESSIBLE RAMP TO THE EAST OF THE BUILDING (MORGAN BUILDING)(D-12) ACCESSORY TO EXISTING EDUCATIONAL FACILITY ON THE SAME LOT WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION."},{"number":"846816","date":"2018-02-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-02","scope":"ADD (1) NEW CILING MONUNTED AHU, (1) NEW CHILLER, (3) NEW VAV'S, (2) NEW REHEAT COILS AND (8) NEW GRD'S FOR PREVIOUSLY RENOVATED LAB SPACE PER APPROVED PLANS."},{"number":"848735","date":"2018-02-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-10-26","scope":"EXTERIOR & INTERIOR ALTERATIONS FOR PROPOSED STRUCTURAL STEEL & WOOD DECKED ACCESSIBLE RAMP TO SERVE EXISTING OFFICE BUILDING WITHIN UNIVERSITY COMPLEX PER APPROVED PLANS INCLUDING MINOR SITE WORK & ASSOCIATED FINISH WORK."},{"number":"847369","date":"2018-02-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-25","scope":"REMOVE OF EXISTING LIGHTING PANELS AIR HANDLER AND OTHER ASSOCIATED. NEW ELECTRIC PANEL LIGHTING AND WIRING DEVICES AS PER NEC 2008 WEST DISTRICT"},{"number":"854838","date":"2018-03-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-24","scope":"FURNISH AND INSTALL 1 VESDA UNIT WITH ASSOCIATED PIPING 2 MONITOR MODULES 2 HORN/STROBES AS PER NEC 2008 WEST DISTRICT"},{"number":"857893","date":"2018-04-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-10-26","scope":"NEW LIGHTING FIXTURES, 120-VOLT POWER ONLY FOR SECURITY DEVICES. EXCLUDES ALL PHONE, DATA, SECURITY, FIRE ALARM, CCTV, ACCESS CONTROL SYSTEMS AND LOW VOLT WIRING.AS PER 2008 NEC. (WEST DISTRICT)"},{"number":"867521","date":"2018-04-13","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"EXPIRED","completedDate":null,"scope":"FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"869768","date":"2018-05-18","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-03-31","scope":"NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. INTERIOR ALTERATIONS. STRUCTURAL AND EXTERIOR WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP WORK. ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK."},{"number":"890156","date":"2018-07-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-02-05","scope":"LEVEL II ALTERATIONS TO EXISTING BUILDING AS SHOWN ON PLANS. NO CHANGE OF USE PROPOSED.** SEPARATE PERMIT REQUIRED FOR M.E.P.S.**"},{"number":"890814","date":"2018-08-14","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2023-03-29","scope":"FOR ALTERATIONS TO AN EXISTING MECHANICAL SYSTEM WITHIN THE BASEMENT THROUGH 4TH FLR AND ROOF OF THE CRET WING OF THE CHEMISTRY BUILDING ON UPENN CAMPUS (WITH NEW DUCTWORK, REGISTERS/DIFFUSERS, ETC.), CONNECTING TO EXISTING AHU ON ROOF TO BE REBALANCED DUE TO ALTERATIONS WORK (SEE AP#869768 FOR BUILDING PERMIT), AS PER PLANS."},{"number":"885863","date":"2018-09-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REPLACE AIR HANDLING UNIT ON ROOF, CHANGE LIGHTING IN BASEMENT AS PER 2008 NEC (WEST DISTRICT) INSTA FA FOR AHU INCLUDING VESDA SYSTEM AS PER NFPA72"},{"number":"903472","date":"2018-09-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-01-07","scope":"RELOCATE 3 LIGHTS,DEMO EXISTING WIREMOLD AND RECEPTACLES.INSTALL 60 RECEPTACLES AND BRANCH CIRCUITS AND WIRE CONTROL VALVES PER 2008 NEC (EDUCATIONAL FACILITY)"},{"number":"903719","date":"2018-09-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-12-12","scope":"CONNECT TO EXISTING DUCTWORK AND RUN NEW TO SERVE 13 FUME HOODS"},{"number":"910430","date":"2018-10-03","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-03-30","scope":"FOR PRESCRIPTIVE ALTERATIONS WITHOUT A CHANGE OF OCCUPANCY WITHIN THE SECOND FLOOR OF THE CHEMISTRY LABORATORIES 1958/1973 WINGS, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; NO WORK TO COMMON AREAS."},{"number":"903721","date":"2018-10-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-12-12","scope":"ALTERATIONS: INTERIOR PLUMBING; LABORATORY RELOCATION; EDUCATIONAL FACILITY; FIRST FLOOR, VAGELES LABORATORY; CUP SINK AND LAB SINKS CONNECT TO EXISTING"},{"number":"925558","date":"2018-11-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-12-09","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"924452","date":"2018-11-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-28","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM FOR UNIVERSITY LABORATORIES TO INCLUDE INSTALLATION OF NEW DISTRIBUTION DUCTWORK, (4) NEW VAV'S AND (6) NEW GRD'S AS PER APPROVED PLANS."},{"number":"927659","date":"2018-11-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-04-23","scope":"INSTALL WASTE PIPING FROM FIXTURES. INSTALL WATER PIPING TO FIXTURES, INSTALL 1- NEW EYE WASH, AND 2- NEW SINKS. ALT PERM #910430"},{"number":"920962","date":"2018-11-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-05-24","scope":"INSTALL 27 DUPLEX RECEPTACLES 80' WIRE MOLD WITH 23 RECEPTACLES 200AMP PANEL BOARD 100AMP PANEL BOARD 25KVA XFORMER 7 POWER PLUGS 32 LIGHT FIXTURES 3 SWITCHES 1 DIMMER"},{"number":"953501","date":"2019-03-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-09-16","scope":"LEVEL 1 ALTERATIONS FOR DEMO. & REPAIR/REPLACEMENT OF EXISTING SUSPENDED CEILING ASSEMBLIES PER APPROVED PLANS; BULDING IS FULLY SPRINKLERED. SEPARATE PERMIT REQ'D FOR ANY ELECTRICAL WORK."},{"number":"966020","date":"2019-05-02","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-03-30","scope":"FOR EXTERIOR FACADE REPAIR FOR AN EXISTING EDUCATION FACILITY, ALL PROPOSED WORK TO BE DONE PER APPROVED PLANS SEALED BY A PROFESSIONAL ENGINEER. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"979636","date":"2019-07-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-09-16","scope":"REMOVE EXISTING LIGHTS, SWITCHES CONDUIT AND WIRE. INSTALL NEW LIGHTS, SWITCHES AND LOW VOLTAGE MOTION SNSORS. REMOVE EXISTING PANEL INTERIOR PP2-A. INSTALL NE PANEL INTERIOR AND RECONNECT EXISTING FEEDER AND BRANCH CIRCUITS. REMOVE AND REINSTALL SMOKE DETECTORS IF THE INTERFEAR WITH CONSTRUCTION AS PER 2008 NEC (WEST DIST)"},{"number":"1009390","date":"2019-10-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-01-28","scope":"LEVEL I INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) TO THE FOURTH FLOOR OF AN EXISTING STRUCTURE AS PER APPROVED PLANS**EXISTING BUILDING FULLY SPRINKLERED**SEPARATE PERMIT REQUIRED FOR ANY MECHANICAL, ELECTRICAL, PLUMBING OR FIRE SUPPRESSION WORK**IEBC 2018*"},{"number":"1026630","date":"2019-11-20","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-28","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM ON THE SECOND AND FOURTH FLOORS OF AN EDUCATIONAL OFFICE BUILDING AS PER APPROVED PLANS."},{"number":"1028544","date":"2019-12-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-12-19","scope":"ALTERATIONS TO COMBINE TWO ROOMS INTO ONE TO INCLUDE THE REMOVAL OF SELECT PARTITIONS, DOOR AND PATCHING AT REMOVED ITEMS AS PER PLANS. NO CHANGE OF OCCUPANCY."},{"number":"1024805","date":"2019-12-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-28","scope":"INSTALL NEW TYPE A LIGHT FIXTURE QTY 6, INSTALL CEILING MOUNTED OCCUPANCY SENSORS QTY 6, SINGLE POLE QTY 3, INSTALL DUPLEX RECEPTACLES QTY 9, INSTALL DOUBLE DUPLEX RECEPTACLES QTY13, INSTALL TYPE B LIGHT FIXTURES QTY 5. INSTALL WORK AS PER DRAWINGS PER 2017 NEC (WEST DIST)"},{"number":"1042160","date":"2020-03-03","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-10-15","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING TOILET ROOM IN AN EXISTING EDUCATIONAL FACILITY (LEVIN BUILDING) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"EP-2020-002052","date":"2020-05-20","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-10-02","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"MP-2020-000202","date":"2020-07-08","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2020-10-15","scope":"FOR THE INSTALLATION OF HVAC DUCTWORK, REGISTERS AND DIFFUSERS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR PLUMBING."},{"number":"PP-2020-002881","date":"2020-07-08","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-10-15","scope":"Relocation of plumbing fixtures"},{"number":"FP-2020-000368","date":"2020-07-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-03-22","scope":"FOR THE INSTALLATION OF SIX (6) INCH FIRE SERVICE LINE WITH SIX (6) INCH EXISTING BACKFLOW PREVENTER, AUTOMATIC FIRE SUPPRESSION SYSTEM AS PER NFPA 13. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. SEPARATE PERMIT REQUIRED FOR ANY OTHER WORK."},{"number":"FP-2020-001132","date":"2020-08-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-10-15","scope":"FOR THE INSTALLATION AND MODIFICATION OF THIRTEEN (13)SPRINKLER HEAD WITH A SIX (6) INCH EXISTING BACKFLOW PREVENTER, AND AN EXISTING FIRE PUMP AS PART OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM AS PER NFPA 13. AT LEVINE HALL 1ST FLOOR BATHROOMS. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. SEPARATE PERMIT REQUIRED FOR ANY OTHER WORK."},{"number":"EP-2020-009096","date":"2020-10-27","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-10-28","scope":"Replace the existing light fixtures. Provide new surface raceway with receptacles. Provide new 20a 1P circuit breaker. No fire alarm and no low voltage wiring as per 2017 nec"},{"number":"CP-2020-005611","date":"2020-12-03","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-12-24","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING LABORATORY (309-311) ON THE THIRD FLOOR OF AN EXISTING UNIVERSITY BUILDING (CHEMISTRY 73, WING D-7) AS PER APPROVED PLANS. EXISTING BUILDING PARTIALLY SPRINKLERED. *2018 IEBC* **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**"},{"number":"PP-2020-014961","date":"2020-12-08","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-12-17","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"EP-2020-011292","date":"2020-12-09","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-02-03","scope":"Rough-In Permit for EP-2020-011288 Relocate (8) lights and (10) switches. Provide (6) new lights and (2) switches. Provide (4) panelboards, (2) bus duct switches, approximately 120' of surface mounted raceway, (74) new circuits, (22) duplex outlets, (10) quad outlets, (10) conduit pathways for tele/data, (7) fume hood connections, (5) horn/strobes, and (1) flow/tamper switch as per 2017 nec and nfpa 72"},{"number":"MP-2020-005807","date":"2020-12-29","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-08-06","scope":"DEMO AND INSTALL DUCTWORK AND TWO LAB HOODS AS PER APPROVED PLANS ON THIRD FLOOR OF EXISTING BUILDING. (CHEMISTRY 73 WING, D-7 - LABORATORY 309-311)"},{"number":"CP-2020-005892","date":"2021-01-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-02-02","scope":"LEVEL I INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING LABORATORY (ROOMS 336 & 436) ON THE 2nd FLOOR OF AN EXISTING UNIVERSITY BUILDIN Skirkanich Hall AS PER APPROVED PLANS. *2018 IEBC* **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**"},{"number":"EP-2020-011288","date":"2021-02-03","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-05-07","scope":"Relocate (8) lights and (10) switches. Provide (6) new lights and (2) switches. Provide (4) panelboards, (2) bus duct switches, approximately 120' of surface mounted raceway, (74) new circuits, (22) duplex outlets, (10) quad outlets, (10) conduit pathways for tele/data, (7) fume hood connections, (5) horn/strobes, and (1) flow/tamper switch as per 2017 nec and nfpa 72"},{"number":"CP-2020-007187","date":"2021-02-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-06-09","scope":"For level II interior alterations to existing academic building as shown on plans. No change of occupancy classification. Building is fully sprinklered. Separate permits required for M.E.P.S work."},{"number":"FP-2021-000379","date":"2021-02-12","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-06-09","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (1) sprinkler head at University of Pennsylvania, Skirkanich Hall Lab 520 (CP-2020-007187)"},{"number":"PP-2021-003049","date":"2021-04-29","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-06-09","scope":"NEW LAB GAS PIPING. TIE-IN (1) CUP SINK IN A LAB HOOD."},{"number":"FP-2021-000183","date":"2021-05-04","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-12-23","scope":"FOR THE EXTENSION OF EXISTING NFPA 13 SPRINKLER SYSTEM TO PROTECT ADDITIONAL SPACE ON 3RD FLOOR AS PER APPROVED PLAN. NO WORK ON EXISTING RISER/BACK-FLOW PREVENTOR"},{"number":"EP-2021-000515","date":"2021-05-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-05-24","scope":"Run new circuits for new electrical outlets. Remove electrical power from casework being removed. Adding additional fire alarm signaling devices. ALL WORK IS TO DONE ACCORDING TO APPROVED DRAWINGS. 2017 NEC and 2016 NFPA-72"},{"number":"CP-2021-001592","date":"2021-06-18","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-05-24","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING SECOND FLOOR LABS IN EXISTING HIGHER EDUCATIONAL FACILITY (1973 WING) AS PER APPROVED PLANS. EXISTING BUILDING PARTIALLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"EP-2021-009490","date":"2021-09-23","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-01-13","scope":"Relocate (8) strip lights, provide (3) wall mounted light fixtures, (7) panelboards, (5) GFCI outlets, (2) duplex, and (1) 30A twist lock receptacle. Provide power to AHU-7, CH-1, GFU-1, and PSV-1. Fire alarm work to include (3) horn strobes, (1) duct detector, and the relocation of (1) pull station. As per APPROVED DRAWINGS- 2017 NEC and 2016 NFPA 72, 2018 PHILA FIRE CODE."},{"number":"MP-2021-006278","date":"2021-10-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-01-25","scope":"FOR MECHANICAL ALTERATIONS ON CHEMISTRY LAB WING OF AN EXISTING UNIVERSITY STRUCTURE, TO INCLUDE NEW AHU'S, VAV'S, FIRE DAMPERS, CHILLER, REGISTERS/DIFFUSERS WITH ASSOCIATED DUCTWORK, AS PER APPROVED PLANS."},{"number":"PP-2021-017878","date":"2021-10-21","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-01-25","scope":"Run a domestic cold water line for new chiller"},{"number":"CP-2021-006449","date":"2021-11-05","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-04-12","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO ROOM 164 ON THE FIRST FLOOR OF AN EXISTING HIGHER EDUCATIONAL FACILITY (HAYDEN HALL) AS PER APPROVED PLANS. EXISTING BUILDING NOT SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**"},{"number":"PP-2021-021237","date":"2021-11-10","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2023-08-11","scope":"Replace WITHOUT PIPING 1 sink"},{"number":"FP-2021-002920","date":"2021-11-18","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2023-06-05","scope":"FOR THE EXTENSION OF AN EXISTING NFPA 13 SPRINKLER SYSTEM TO PROTECT ADDITIONAL SPACE ON THE 2ND FLOOR, AS PER THE APPROVED PLAN. NO WORK ON EXISTING RISER/BACK-FLOW PREVENTER."},{"number":"CP-2021-007144","date":"2021-12-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-05-04","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO SECOND FLOOR TOILET ROOM WITH AN EXISTING HIGHER EDUCATIONAL FACILITY (CHEMISTRY LABORATORIES, D-7) AS PER APPROVED PLANS. EXISTING BUILDING PARTIALLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"EP-2021-015205","date":"2021-12-22","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-04-20","scope":"Demolish existing lighting and receptacles. Provide new lights and receptacles using existing circuits. as per 2017 NEC"},{"number":"EP-2021-015828","date":"2022-01-04","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-01-14","scope":"Furnish and Install new lighting fixtures. Furnish and install new wiremold and outlets. Furnish and install new disconnect switch. Use existing circuits in room as per 2017 nec"},{"number":"MP-2021-007499","date":"2022-01-19","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2023-03-30","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"MP-2021-008934","date":"2022-01-19","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-05-04","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 3 Diffusers *Only* No other work approved for this permit."},{"number":"PP-2021-025002","date":"2022-01-26","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-05-04","scope":"Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018."},{"number":"EP-2022-000685","date":"2022-02-07","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-03-25","scope":"Replace in kind (2) panelboards. No building permit, walls are existing to remain. All work is surface mounted and exposed by means of surface raceway using Wiremold 4800 series and EMT. Provide 15' of Wiremold raceway with (18) outlets, (6) additional outlets installed on existing walls, backbox and pathway for (2) teledata locations, tie (2) new vav's into existing circuit as per 2017 NEC"},{"number":"CP-2022-003176","date":"2022-08-08","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-07-11","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"MP-2022-005181","date":"2022-10-24","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-07-10","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"PP-2022-014591","date":"2022-11-17","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-07-11","scope":"INSTALL 24 CUP SINKS, 3 EYE WASHERS, 2 EMERGENCY SHOWERS, 2 DISHWASHERS AND 2 LAB SINKS ACCORDING TO THE 2018 PPC."},{"number":"EP-2022-010976","date":"2022-11-18","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-06-13","scope":"Installation of approx (44) linear pendant hung light fixtures, (8) ceiling occupancy sensors, (3) remote controllers, (8) switches. Provide (85) duplex outlets, (5) box and pathway to ceiling for data, approx 100' of dual channel surface raceway with (70) duplex outlets and (3) data spaces, (4) furniture hardwire connections, (17) phoenix valves, (4) panelboards, fire alarm work to include (6) horn/strobe devices . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"CP-2022-006700","date":"2023-01-20","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-12-04","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING LABORATORY ON FIFTH FLOOR (ROY AND DIANA VAGELOS LABORATORIES (IAST), D-10) OF AN EXISTING UNIVERSITY BUILDING AS PER APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**"},{"number":"PP-2023-003147","date":"2023-03-13","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-12-04","scope":"Install waste piping from fixtures. Install water piping to fixture. Install 3 Lab sinks, (2) replacements (1) new. 2 emergency eyewash, (1) replacement (1) new."},{"number":"MP-2023-001130","date":"2023-04-10","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-12-04","scope":"FOR ALTERATIONS TO HVAC SYSTEM INCLUDING NEW VALVES, DIFFUSERS AND ASSOCIATED DUCT WORK AS PER PLANS."},{"number":"EP-2023-003337","date":"2023-04-20","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-11-03","scope":"select demolition install 27 new light fixtures 14 new lighting control devices 63 receptacles 4 new fire alarm devices. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"CP-2023-001712","date":"2023-05-04","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2025-08-13","scope":"AMENDMENT: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT: CP-2023-001712 TO DOCUMENT CHANGE IN ACHORING DETAIL RESULTING IN NO SPECIAL INSPECTION REQUIRED FOR PROPOSED SCOPE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ORIGINAL: FOR EXTERIOR FACADE IMPROVEMENTS TO AN EXISTING COMMERCIAL BUILDING, ALTERATIONS TO BE DONE PER APPROVED PLANS SEALED BY A STRUCTURAL ENGINEER. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2023-001178","date":"2023-06-20","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-02-04","scope":"FOR ALTERATIONS TO THE EXISTING FIRE SUPPRESSION SYSTEM TO INSTALL NEW SPRINKLER AND PIPING AS PER PLANS."},{"number":"FP-2023-001496","date":"2023-06-27","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-12-04","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Modify (14) sprinklers to accommodate renovations to existing 5th floor laboratories"},{"number":"CP-2023-003743","date":"2023-09-15","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-05-27","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING CHEMISTRY LABORATORY SPACE D-7. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS. FOR USE AS PREVIOUSLY APPROVED. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE AS PER APPROVED PLANS. ***********SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ***********"},{"number":"CP-2023-005666","date":"2023-10-16","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-07-26","scope":"FOR A LEVEL I INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY ) TO A PORTION OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE SELECTIVE DEMOLOTION AND REPLACEMENT OF EXISTING PARTITION AND PROVIDE FINISHES AND FURNISHINGS THROUGHOUT AS PER APPROVED PLANS. ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK**IEBC 2018**EXISTING BUILDING FULLY SPRINKLERED** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**"},{"number":"MP-2023-004665","date":"2023-11-14","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-07-26","scope":"FOR THE INSTALLATION OF A NEW HVAC SYSTEMS, ASSOCIATED DUCT WORK, DUCTLESS SYSTEMS, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION."},{"number":"FP-2023-002759","date":"2023-11-22","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-05-27","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"EP-2023-010796","date":"2023-11-27","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-02-09","scope":"Furnish and install new lighting fixtures. Furnish and install new wire mold and outlets. Furnish and install new disconnect switch. AS PER NEC 2017"},{"number":"EP-2023-011252","date":"2023-12-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-07-24","scope":"REMOVE THE EXISTING PANEL PP-1 AND REPLACE WITH NEW 100 AMP PANEL PP-1. RELOCATE EXISTING RECEPTACLES. PROVIDE POWER FOR THE NEW FCU'S VFD'S AND BAS EQUIPMENT USING EXISTING CIRCUITS AVAILABLE FROM THE DEMO OF THE OLD EQUIPMENT."},{"number":"MP-2023-005093","date":"2023-12-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-05-27","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"PP-2023-015869","date":"2023-12-15","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-05-27","scope":"Relocation of Emergency Sink and adding new eyewash (OTHER) and faucet with associated new domestic water and waste piping."},{"number":"GM-2024-003670","date":"2024-04-23","work":"Roof Covering Replacement","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2025-11-10","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2024-001659","date":"2024-04-26","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-08-13","scope":"FOR A LEVEL II INTERIOR ALTERATIONS TO THE FIRST FLOOR OF AN EXISTING EDUCATIONAL FACILITY. ALTERATIONS TO INCLUDE THE CREATION OF TWO (2) ACCESSIBLE RESTROOMS . WORK TO CONSIST OF ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT THE DESIGNATED AREA. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**ASBESTOS REMEDIATION REQUIRED PRIOR TO START OF WORK**"},{"number":"MP-2024-002236","date":"2024-05-31","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-08-12","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"PP-2024-007050","date":"2024-06-12","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-08-13","scope":"ALTERATIONS AS PER APPROVED DRAWINGS TO INCLUDE (2) TOILETS, (2) LAV SINKS, & (2) FLOOR DRAINS. 6 FIXTURES."},{"number":"FP-2024-001292","date":"2024-06-24","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-08-12","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (3) sprinkler heads to accommodate interior alterations"},{"number":"EP-2024-004951","date":"2024-07-01","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-08-06","scope":"DEMO, TEMP POWER&LIGHTING, NEW LIGHT FIXTURES/CONTROLS, NEW GFCI OUTLETS POWER TO NEW EXHAUST FANS/ ADD (2) CEILING STROBE FIRE ALARM DEVICES-2017 NEC,2016 NFPA-72."},{"number":"FP-2024-001603","date":"2024-09-16","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-02-04","scope":"FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE NEW SPRINKLER HEADS TO BE TIED INTO THE EXISTING SYSTEM AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"FP-2024-001824","date":"2024-09-16","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-02-04","scope":"EXTENSION OF EXISTING SPRINKLER SYSTEM TO GROUND FLOOR OF CHEMISTRY 1958 WING FROM EXISTING SYSTEM RISER IN ACCORDANCE WITH NFPA 13 STANDARD AND AS PER APPROVED PLANS. NO WORK TO EXISTING FIRE SERVICE MAIN, MAIN SPRINKLER RISER OR BACKFLOE ASSEMBLY."},{"number":"CP-2024-004612","date":"2024-09-18","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-02-03","scope":"FOR AN ALTERATION TO A PORTION OF AN EXITING STRUCTURE. STRUCTURAL WORK TO BE LIMITED TO WALL INFILL. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"MP-2024-004438","date":"2024-11-22","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-01-30","scope":"FOR ALTERATION TO THE HVAC SYSTEM AS PER APPROVED PLANS."},{"number":"CP-2024-005910","date":"2024-12-05","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-06-10","scope":"FOR REPAIRS TO A PORTION OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**ASBESTOS REMEDIATION REQUIRED PRIOR TO START OF WORK**"},{"number":"CP-2024-005680","date":"2024-12-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-05-05","scope":"FOR A LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 2ND FLOOR LEVEL OF AN EISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"PP-2024-017111","date":"2024-12-17","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-06-09","scope":"Demo old underground piping and floor drain, installation of new Floor Drain, Floor Sink, (2) Floor Cleanouts."},{"number":"FP-2024-002623","date":"2024-12-19","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-05-05","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (34) sprinkler heads to accommodate interior alterations to 2nd floor lab"},{"number":"EP-2024-011902","date":"2025-01-02","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-12-11","scope":"DISCONNECT THE EXISTING ELEVATOR FEEDERS & EQUIPMENT, LIGHTS, SWITCHES & RECEPTACLES. INSTALL NEW DISCONNECT SWITCHES & FEEDERS FOR THE NEW ELEVATOR EQUIPMENT. INTALL NEW LIGHTS, SWITCHES & GFCI RECEPTACLES IN THE ELEVATOR MACHINE ROOM & ELEVATOR PITS. PROVIDE POWER FOR THE HAVC EQUIPMENT. INSTALL FIRE ALARM SMOKE & HEAT DETECTORS IN THE ELEVATOR MACHINE ROOM, ELEVATOR SHAFTS & PITS. INSTALL FIRE ALARM SHUNT TRIP MODULES. ALL WORK IN ACCORDANCE WITH THE 2017 NEC."},{"number":"MP-2024-005876","date":"2025-01-06","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-06-09","scope":"FOR THE INSTALLATION OF HVAC APPLIANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS."},{"number":"MP-2025-000074","date":"2025-01-13","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-05-05","scope":"FOR THE INSTALLATION OF HVAC APPLIANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS AT 'CHEMISTRY 1958 WING' PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS."},{"number":"EP-2025-000386","date":"2025-01-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-05-19","scope":"REMOVE THE EXISTING LIGHT FIXTURES. INSTALL NEW LIGHTS FIXTURES & TIMER SWITCHES USING THE EXISTING CIRCUITS. INSTALL THE BAS PANEL & PROVIDE POWER FOR THE NEW HVAC EQUIPMENT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. * THE ELECTRIC PANELS ARE EXISTING ."},{"number":"EP-2025-000014","date":"2025-01-23","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-04-15","scope":"DEMO TEMP POWER/LIGHTING..NEW LIGHT FIXTURES&CONTROLS NEW POWER. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**"},{"number":"FP-2025-000499","date":"2025-03-11","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-01-30","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (1) sprinkler head"},{"number":"PP-2025-000426","date":"2025-04-23","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-05-05","scope":"RENOVATION TO EXISTING LAB. INSTALLATION OF MEDICAL GAS PIPING, EQUIPMENT, AND ASSOCIATED REGULATORS/MANIFOLDS PER NFPA 99. INSTALLATION OF ASSOCIATED PIPING TO COMPUTER ROOM EQUIPMENT AND CONDENSATE DISPOSAL PER 2018 PPC AND APPROVED PLANS."},{"number":"GP-2025-003642","date":"2025-04-23","work":"Shelter/Platform","type":"General","description":"General Permit","status":"Issued","completedDate":null,"scope":"FOR THE ERECTION OF A SIDEWALK SHELTER PLATFORM. SIZE AND LOCATION AS PER PLANS. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"CP-2025-002140","date":"2025-05-05","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-10-29","scope":"FOR A FACADE REMOVATION.** WORK TO BE COMPLETED PER APPROVED PLANS**"},{"number":"GM-2026-003315","date":"2026-04-23","work":"Roof Covering Replacement","type":"General Permit Minor","description":"General Permit Minor","status":"Issued","completedDate":null,"scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2026-001013","date":"2026-05-05","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR EXTERIOR ALTERATIONS AT THE ROOF TO INSTALL FALL-PROTECTION GUARDS AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Alterations"},{"y":2025,"k":"permit","w":"Shelter/Platform"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"insp","w":"L&I: 2 failed, 1 passed"},{"y":2026,"k":"permit","w":"Roof Covering Replacement"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"}],"rented":false,"licenses":[{"number":"464313","type":"Hazardous Materials","status":"Inactive","businessName":"HEALY LONG JEVEIN AND MG CEMENT WORK","legalName":"HEALY LONG JEVEIN AND MG CEMENT WORK","address":"221 S 34TH ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2009-01-29","latestIssueDate":"2009-01-29","expirationDate":"2009-04-30","inactiveDate":null},{"number":"471962","type":"Hazardous Materials","status":"Active","businessName":"U OF P EHRS (MATTHEW FINUCANE)","legalName":"U OF P EHRS","address":"221 S 34TH ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2009-05-05","latestIssueDate":"2026-02-05","expirationDate":"2026-12-31","inactiveDate":null},{"number":"471945","type":"Hazardous Materials","status":"Active","businessName":"U OF P EHRS (MATTHEW FINUCANE)","legalName":"U OF P EHRS","address":"221 S 34TH ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2009-05-05","latestIssueDate":"2026-03-05","expirationDate":"2026-12-31","inactiveDate":null},{"number":"528604","type":"Dumpster License - Private Property","status":"Active","businessName":"UNIVERSITY OF PENNA TRUSTEES","legalName":"UNIVERSITY OF PENNA TRUSTEES","address":"221 S 34TH ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2011-03-25","latestIssueDate":"2013-08-10","expirationDate":null,"inactiveDate":null},{"number":"558345","type":"Hazardous Materials","status":"Inactive","businessName":"UNIVERSITY OF PENNA TRUSTEES","legalName":"UNIVERSITY OF PENNA TRUSTEES","address":"221 S 34TH ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2013-07-09","latestIssueDate":"2013-07-09","expirationDate":"2013-12-31","inactiveDate":null}],"licenseActivity":[{"number":"558345","type":"Hazardous Materials","businessName":"UNIVERSITY OF PENNA TRUSTEES","legalName":"UNIVERSITY OF PENNA TRUSTEES","issuedDate":"2013-07-09","latestIssueDate":"2013-07-09","closureDate":"2013-12-31","expirationDate":"2013-12-31","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"528604","type":"Dumpster License - Private Property","businessName":"UNIVERSITY OF PENNA TRUSTEES","legalName":"UNIVERSITY OF PENNA TRUSTEES","issuedDate":"2011-03-25","latestIssueDate":"2013-08-10","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"471945","type":"Hazardous Materials","businessName":"U OF P EHRS (MATTHEW FINUCANE)","legalName":"U OF P EHRS","issuedDate":"2009-05-05","latestIssueDate":"2026-03-05","closureDate":null,"expirationDate":"2026-12-31","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"464313","type":"Hazardous Materials","businessName":"HEALY LONG JEVEIN AND MG CEMENT WORK","legalName":"HEALY LONG JEVEIN AND MG CEMENT WORK","issuedDate":"2009-01-29","latestIssueDate":"2009-01-29","closureDate":"2009-04-30","expirationDate":"2009-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-27","signals":[{"kind":"record-pressure","level":"elevated","title":"Records to verify together","summary":"More than one separately dated public record deserves a current-status check.","evidence":["6 open L&I violations","failed L&I inspection activity in 2022, 2023, 2025"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."},{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["11 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #158832: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"26 permits not marked completed: 336473 (Issued), 478248 (EXPIRED), 491037 (EXPIRED), 511737 (EXPIRED), 517447 (EXPIRED). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"6 open L&I violations","finding":"14 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"10 failed, 3 passed, and 0 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Jun 26, 2025.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"verify","title":"A fire-system permit exists, but no annual certification matched","finding":"68 fire/suppression-related permits matched; the fetched BIN certification feed returned no row.","why":"Installed systems in mixed-use and larger buildings generally require periodic certification, but applicability and limited-area exceptions vary. A missing BIN/address join is not proof of a compliance failure.","action":"Confirm what system was installed and whether a current annual certificate is required and filed.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Hazardous Materials #464313: Inactive; Hazardous Materials #558345: Inactive","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"full-tax-exemption","level":"verify","title":"OPA shows a full exemption; its legal basis is unverified","finding":"OPA currently marks the land and building assessment fully tax-exempt; BlockReport does not receive the exemption determination or basis.","why":"Full OPA exemptions can have different legal bases, including government, religious, charitable/institutional, veteran, or other treatment. The current owner/use record is not a buyer’s tax forecast.","action":"Confirm the exact exemption basis, buyer eligibility, and next tax-year treatment directly with OPA.","url":"https://www.phila.gov/departments/office-of-property-assessment/tax-exemptions-and-abatements/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as commercial. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}