{"asOf":"2026-07-23T23:09:36.635Z","block":"10800-10899 KNIGHTS RD","blockUrl":"https://philadelphia.blockreport.homes/block/10800-10899-knights-rd","address":"10800 KNIGHTS RD","parcelNumber":"778017000","source":"https://property.phila.gov/?p=778017000","ownerType":"investor","kind":"commercial","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":true,"institutional":false,"buildingCode":"YA0","buildingCodeNew":"640","buildingClass":"HEALTH FAC HOSP MASONRY","buildingClassNew":"HOSPITAL","useLabel":"Commercial","owner":"FRANKFORD HOSPITAL","coOwner":"TORRESDALE DIVISION","marketValue":21777700,"landAssessment":2831101,"improvementAssessment":18946599,"livableArea":444322,"yearBuilt":1970,"lastSale":{"price":1,"date":"1973-11-14T05:00:00Z"},"openViolations":0,"violations":[{"number":"560959","date":"2007-05-02","code":"FC-605.5/1","title":"FIRE-ELECT EXT CORDS PROHIB","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"560956","date":"2007-05-02","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"560957","date":"2007-05-02","code":"FC-901.4/1","title":"OBTAIN PERMIT EXTEN SPRKLR SYS","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"560958","date":"2007-05-02","code":"FC-905.11/1","title":"EXIST BLDG 50 ABOVE/BELOW","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"766582","date":"2007-12-10","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"766583","date":"2007-12-10","code":"FC-508.5/1","title":"FIRE PROT-HYDRANT REQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818959","date":"2008-01-28","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818957","date":"2008-01-28","code":"A-402.1/4","title":"COMPL CONCEAL- PLUMB PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818958","date":"2008-01-28","code":"A-402.5/5","title":"PERMP- FINAL PRE-CO INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1698450","date":"2008-05-14","code":"FC-1004.3/1","title":"EGRESS-ASSEM OCC SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1185330","date":"2008-07-18","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1435989","date":"2009-06-15","code":"A-301.1/21","title":"PERMB- FLAT WALL SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3203181","date":"2013-06-12","code":"LR-1","title":"RENEW LIC INDICATED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3203180","date":"2013-06-12","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3183858","date":"2014-05-16","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3183857","date":"2014-05-16","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5307309","date":"2020-02-03","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"5307493","date":"2020-02-04","code":"A-301.1/56","title":"PERMP- INST SANITARY PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818951","date":"2008-01-28","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818953","date":"2008-01-28","code":"A-402.5/5","title":"PERMP- FINAL PRE-CO INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818952","date":"2008-01-28","code":"A-402.1/4","title":"COMPL CONCEAL- PLUMB PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"111220","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2007-05-03","completedDate":null,"violations":[{"number":"560959","date":"2007-05-02","code":"FC-605.5/1","title":"FIRE-ELECT EXT CORDS PROHIB","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"560956","date":"2007-05-02","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"560957","date":"2007-05-02","code":"FC-901.4/1","title":"OBTAIN PERMIT EXTEN SPRKLR SYS","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"560958","date":"2007-05-02","code":"FC-905.11/1","title":"EXIST BLDG 50 ABOVE/BELOW","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"138194","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2007-12-11","completedDate":"2008-01-11","violations":[{"number":"766582","date":"2007-12-10","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"766583","date":"2007-12-10","code":"FC-508.5/1","title":"FIRE PROT-HYDRANT REQ","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"144565","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2008-01-28","completedDate":"2008-02-12","violations":[{"number":"818959","date":"2008-01-28","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818957","date":"2008-01-28","code":"A-402.1/4","title":"COMPL CONCEAL- PLUMB PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818958","date":"2008-01-28","code":"A-402.5/5","title":"PERMP- FINAL PRE-CO INSP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"160249","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2008-05-15","completedDate":"2010-07-09","violations":[{"number":"1698450","date":"2008-05-14","code":"FC-1004.3/1","title":"EGRESS-ASSEM OCC SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"169998","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2008-07-18","completedDate":"2010-08-16","violations":[{"number":"1185330","date":"2008-07-18","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"203221","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2009-06-15","completedDate":"2010-08-16","violations":[{"number":"1435989","date":"2009-06-15","code":"A-301.1/21","title":"PERMB- FLAT WALL SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"385755","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-06-13","completedDate":null,"violations":[{"number":"3203181","date":"2013-06-12","code":"LR-1","title":"RENEW LIC INDICATED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3203180","date":"2013-06-12","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"432083","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-05-19","completedDate":"2014-07-07","violations":[{"number":"3183858","date":"2014-05-16","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3183857","date":"2014-05-16","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"723272","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2020-02-03","completedDate":"2020-02-04","violations":[{"number":"5307309","date":"2020-02-03","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"723304","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2020-02-04","completedDate":"2020-03-06","violations":[{"number":"5307493","date":"2020-02-04","code":"A-301.1/56","title":"PERMP- INST SANITARY PIPE SYS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"91348","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"818951","date":"2008-01-28","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818953","date":"2008-01-28","code":"A-402.5/5","title":"PERMP- FINAL PRE-CO INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"818952","date":"2008-01-28","code":"A-402.1/4","title":"COMPL CONCEAL- PLUMB PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2007,"n":6,"worst":null},{"y":2008,"n":8,"worst":null},{"y":2009,"n":1,"worst":null},{"y":2013,"n":2,"worst":null},{"y":2014,"n":2,"worst":null},{"y":2020,"n":2,"worst":null}],"investigations":[{"caseNumber":"10828","date":"2004-03-25","type":"L_CLIP","status":"CLOSED"},{"caseNumber":"111220","date":"2007-05-02","type":"CI INSP","status":"FAILED"},{"caseNumber":"138194","date":"2007-12-10","type":"CI INSP","status":"FAILED"},{"caseNumber":"138194","date":"2008-01-10","type":"CI INSP","status":"PASSED"},{"caseNumber":"144565","date":"2008-01-28","type":"PP_PLUMB","status":"FAILED"},{"caseNumber":"144565","date":"2008-02-12","type":"PP_PLUMB","status":"PASSED"},{"caseNumber":"160249","date":"2008-05-15","type":"CI INSP","status":"FAILED"},{"caseNumber":"169998","date":"2008-07-18","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"169998","date":"2008-08-22","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"160249","date":"2008-11-10","type":"CI INSP","status":"FAILED"},{"caseNumber":"169998","date":"2008-12-12","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"169998","date":"2009-03-30","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"203221","date":"2009-06-12","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"203221","date":"2009-07-20","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"203221","date":"2009-08-24","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"203221","date":"2009-09-28","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"160249","date":"2010-01-13","type":"CI INSP","status":"FAILED"},{"caseNumber":"160249","date":"2010-02-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"160249","date":"2010-03-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"160249","date":"2010-04-26","type":"CI INSP","status":"PASSED"},{"caseNumber":"160249","date":"2010-05-26","type":"CI INSP","status":"PASSED"},{"caseNumber":"160249","date":"2010-07-08","type":"CI INSP","status":"PASSED"},{"caseNumber":"385755","date":"2013-06-12","type":"CI INSP","status":"FAILED"},{"caseNumber":"385755","date":"2013-10-28","type":"CI INSP","status":"FAILED"},{"caseNumber":"385755","date":"2014-02-06","type":"CI INSP","status":"CLOSED"},{"caseNumber":"385755","date":"2014-04-21","type":"PRECOURT","status":"FAILED"},{"caseNumber":"432083","date":"2014-05-16","type":"CI INSP","status":"FAILED"},{"caseNumber":"385755","date":"2014-06-03","type":"PRECOURT","status":"FAILED"},{"caseNumber":"432083","date":"2014-07-03","type":"CI INSP","status":"PASSED"},{"caseNumber":"723272","date":"2020-02-03","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"723272","date":"2020-02-04","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"723304","date":"2020-02-04","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"723304","date":"2020-03-06","type":"BP_BLDG","status":"PASSED"}],"inspYears":[{"y":2007,"fails":2,"passes":0},{"y":2008,"fails":4,"passes":4},{"y":2009,"fails":2,"passes":3},{"y":2010,"fails":3,"passes":3},{"y":2013,"fails":2,"passes":0},{"y":2014,"fails":3,"passes":1},{"y":2020,"fails":2,"passes":2}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":40.07117795973204,"lng":-74.98307813777505,"geom":{"type":"Polygon","coordinates":[[[-74.981490424,40.071255949],[-74.981728651,40.068991808],[-74.981814105,40.068488218],[-74.981932463,40.067988576],[-74.985490487,40.072020834],[-74.984971605,40.072335476],[-74.984625776,40.072722468],[-74.98428227,40.072978027],[-74.984100237,40.073048211],[-74.983942055,40.073231133],[-74.983487951,40.073568965],[-74.982896433,40.07315638],[-74.981321361,40.071969607],[-74.981308456,40.071927806],[-74.9814089,40.071658246],[-74.981490424,40.071255949]],[[-74.981804741,40.071342922],[-74.981865901,40.071319351],[-74.981880322,40.071341436],[-74.981944197,40.071316817],[-74.981929777,40.071294734],[-74.982493489,40.071077571],[-74.98235577,40.070867366],[-74.981943066,40.071026418],[-74.981852709,40.070888029],[-74.981791547,40.070911599],[-74.981777128,40.070889517],[-74.981713093,40.070914194],[-74.98172751,40.070936277],[-74.981577081,40.07099425],[-74.981804741,40.071342922]]]},"liDistrict":"EAST","certifications":[{"number":"BC-2023-005987","type":"Special Hazards Certification","inspectionDate":"2023-03-15","result":"Certified","expirationDate":"2024-03-15","buildingId":"1289766"},{"number":"BC-2023-006001","type":"Special Hazards Certification","inspectionDate":"2023-03-21","result":"Certified","expirationDate":"2024-03-21","buildingId":"1289766"},{"number":"BC-2024-002348","type":"Special Hazards Certification","inspectionDate":"2023-09-20","result":"Certified","expirationDate":"2024-03-20","buildingId":"1289766"},{"number":"BC-2024-002307","type":"Special Hazards Certification","inspectionDate":"2023-09-20","result":"Certified","expirationDate":"2024-03-20","buildingId":"1289766"},{"number":"BC-2024-002349","type":"Special Hazards Certification","inspectionDate":"2023-09-20","result":"Deficient","expirationDate":null,"buildingId":"1289766"},{"number":"BC-2024-002312","type":"Special Hazards Certification","inspectionDate":"2023-11-27","result":"Certified","expirationDate":"2024-05-27","buildingId":"1289766"},{"number":"BC-2024-003292","type":"Fire Alarm Certification","inspectionDate":"2024-01-30","result":"Certified","expirationDate":"2025-01-30","buildingId":"1289766"},{"number":"BC-2024-006707","type":"Special Hazards Certification","inspectionDate":"2024-03-12","result":"Certified","expirationDate":"2024-09-12","buildingId":"1289766"},{"number":"BC-2024-006713","type":"Special Hazards Certification","inspectionDate":"2024-03-13","result":"Certified","expirationDate":"2024-09-13","buildingId":"1289766"},{"number":"BC-2024-011586","type":"Fire Alarm Certification","inspectionDate":"2024-04-19","result":"Certified","expirationDate":"2025-04-19","buildingId":"1289766"},{"number":"BC-2024-020033","type":"Fire Alarm Certification","inspectionDate":"2024-06-12","result":"Certified","expirationDate":"2025-06-12","buildingId":"1289766"},{"number":"BC-2024-024775","type":"Fire Alarm Certification","inspectionDate":"2024-08-01","result":"Certified","expirationDate":"2025-08-01","buildingId":"1289766"},{"number":"BC-2024-024773","type":"Fire Alarm Certification","inspectionDate":"2024-08-01","result":"Certified","expirationDate":"2025-08-01","buildingId":"1289766"},{"number":"BC-2024-024754","type":"Special Hazards Certification","inspectionDate":"2024-09-04","result":"Certified","expirationDate":"2025-09-04","buildingId":"1289766"},{"number":"BC-2025-006711","type":"Special Hazards Certification","inspectionDate":"2025-03-12","result":"Certified","expirationDate":"2026-03-12","buildingId":"1289766"},{"number":"BC-2025-015253","type":"Special Hazards Certification","inspectionDate":"2025-05-29","result":"Certified","expirationDate":"2026-05-29","buildingId":"1289766"},{"number":"BC-2025-024059","type":"Special Hazards Certification","inspectionDate":"2025-09-10","result":"Certified","expirationDate":"2026-09-10","buildingId":"1289766"},{"number":"BC-2026-007939","type":"Special Hazards Certification","inspectionDate":"2026-03-04","result":"Certified","expirationDate":"2027-03-04","buildingId":"1289766"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19114","beds":null,"baths":null,"stories":null,"lotArea":1194813,"zoning":"SPINS","grade":"B","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"10800 KNIGHTS RD, PHILADELPHIA PA, 19154","mailOut":false,"appeals":[{"type":"Building standards appeal","grounds":"DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED VIOLATION NOTICE #169998 ON 7/18/08.  INSTALLATION OF COMBINATION SMOKE/FIRE DAMPERS PER CODE SECTION 716.5.3","status":"OPEN","outcome":"Denied","date":"2008-10-01","number":"6551","relatedPermit":"169998"},{"type":"Building standards appeal","grounds":"ON 10/15/2012, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #430605.","status":"OPEN","outcome":"APPROVED","date":"2012-11-29","number":"19211","relatedPermit":"430605"},{"type":"Zoning board appeal","grounds":"PERMIT FOR THE REMOVAL OF THIRTEEN (13) FREE-STANDING SIGNS AND TWO (2) FLAT-WALL SIGNS AND THE INSTALLATION OF SIX (6) DOUBLE-FACE, STATICALLY ILLUMINATED FREE-STANDING SIGNS [SIGNS 1, 3 & 5\nTHROUGH 8], TWO (2) SINGLE-FACE, STATICALLY ILLU","status":"OPEN","outcome":"Granted","date":"2018-10-03","number":"34461","relatedPermit":"843003"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":20428400,"taxable":0,"land":3582700,"improvement":16845700,"taxableLand":0,"taxableImprovement":0,"exemptLand":3582700,"exemptImprovement":16845700},{"y":2017,"v":20428400,"taxable":0,"land":3582700,"improvement":16845700,"taxableLand":0,"taxableImprovement":0,"exemptLand":3582700,"exemptImprovement":16845700},{"y":2018,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2019,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2020,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2021,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2022,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2023,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2024,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2025,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2026,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599},{"y":2027,"v":21777700,"taxable":0,"land":2831101,"improvement":18946599,"taxableLand":0,"taxableImprovement":0,"exemptLand":2831101,"exemptImprovement":18946599}],"taxNow":0,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"42947","date":"2007-01-30","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2007-06-28","scope":"REVISION PLAN PERMIT #182652. PLAN # 4711-A-05"},{"number":"50055","date":"2007-01-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-10-15","scope":"INSTALL SOIL/WASTE/DOMESTIC WATER, PLUMBING FIXTURES"},{"number":"45499","date":"2007-02-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-23","scope":"INSTALLATION OF ALL ELECTRICAL, INCLUDING 834 LIGHT FIXTURES, 280 SWITCHES, 340 RECEPTS, 8 PANELS AND MISC CONDUIT AND FEEDERS AS SHOWN ON SINGLE LINE"},{"number":"60787","date":"2007-03-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-13","scope":"INSTALL 2 TAMPER SWITCHES AND 2 FLOW SWITCHES. (FA) (EAST DIST)"},{"number":"64989","date":"2007-04-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"RELOCATE 188 EXISTING SPRINKLER HEADS."},{"number":"57754","date":"2007-04-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"NSTALL PRE-ACTION SYSTEM AND 70 SPRINKLERS."},{"number":"74737","date":"2007-05-09","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-11-07","scope":null},{"number":"73859","date":"2007-05-10","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2007-11-07","scope":"AMEND PERMIT # 62512 FOR ADDRESS COREECTION."},{"number":"75960","date":"2007-05-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-09","scope":"INSTALL 17 VOICE/DATA COMMUNICATIONS OUTLETS CAT5E PLENUM RATED, LONGEST RUN (EAST DIST)"},{"number":"75294","date":"2007-05-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-21","scope":"ALTERATION TO EXISTING DOCTORS OFFICE: 100 DUPLEX RECEPTACLES, 10 GFI'S, 65 LAYINS - SWITCH OUT, 2 AC UNITS, NO FIRE ALARM OR COMMUNICATIONS. (EAST DIST)"},{"number":"73860","date":"2007-06-05","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2007-12-31","scope":"AMEND PERMIT # 66032 FOR ADDRESS COREECTION."},{"number":"84230","date":"2007-06-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-03","scope":"INSTALL 15 VOICE/DATA OUTLETS, CATEGORY 5E PLENUM CABLE EXISTING PANEL, LONGEST RUN 150', 2 JACKS PER FACE PLATE (EAST DIST)"},{"number":"83397","date":"2007-06-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-11-14","scope":"REMOVE & REPLACE A LINEAR ACCELERATER. WORK INCLUDES ARCHITECTURAL FINISHES DISTURBED BY EQUIPMENT REPLACEMENT AS PER PLANS"},{"number":"91348","date":"2007-07-23","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-02-12","scope":"REPLACE FIX WITH NEW, REPLACE 3 WATER CLOSETS, 3 LAVYS, 10 SINKS"},{"number":"91471","date":"2007-08-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"VOICE/DATA AND NURSE CALL CABLING. ALL LOW VOLTAGE COMMUNICATIONS (EAST DISTRICT)"},{"number":"96107","date":"2007-08-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-12-14","scope":"SUPPLY AND INSTALL 5 HORN STROBES AND 1 DUCT DETECTOR. (EAST DIST)"},{"number":"92814","date":"2007-08-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-27","scope":"RENOVATION OF LINEAR ACCELERATOR LAB WITH NEW LT FXTS, EQUIPMENT POWER, RECEPTACLES, HVAC, POWER AND VOICE/DATA OUTLETS. EXISTING FIRE ALARM DEVICES WILL BE RE-INSTALLED IN NEW CEILING TILES.(EAST DIST)"},{"number":"93828","date":"2007-09-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-23","scope":"INSTALL THE FOLLOWING: (5) SMOKE DETECTORS, (7) PULL STATIONS, (20) CHIMES/STROBES, (16) STROBES, (70) DUCT DET, AND (10) DOOR HOLDERS IN ACCORDANCE WITH ATTACHED DRAWINGS. PLEASE REFER TO ATTACHED PERMIT. (EAST DIST)."},{"number":"103300","date":"2007-09-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-04-16","scope":"REMOVE & REPLACE THREE (3) GRD'S AT BASEMENT LEVEL OF HOSPITAL"},{"number":"104046","date":"2007-09-19","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-11-07","scope":null},{"number":"117138","date":"2007-12-06","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2007-12-06","scope":"NO CHANGE IN USE (HOSPITAL); REPLACEMENT OF PRIMARY & RESERVE OXYGEN TANKS"},{"number":"143010","date":"2008-04-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-03-19","scope":"INSTALL 2\" RIGID CONDUIT FROM HOSPITAL MONITOR PANEL TO EXTERIOR OXYGEN TANKS, 2 18/2 TSP CABLES & REMOVE 2 LIGHT POLES & REPLACE WITH NEW AS PER 2005 NEC ATRICLE 517."},{"number":"142637","date":"2008-05-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-10-07","scope":"THE DEMOLITION OF EXISTING CONCRETE PAD AND INSTALL A NEW CONCRETE PAD AND 6'-0\"HIGH FENCE FOR OXYGEN TANK."},{"number":"7022","date":"2008-05-16","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2008-05-16","scope":"ERECT 30 X 40 & 30 X 70 TENTS AT REAR OF HOSPITAL LOADING DOCK"},{"number":"157571","date":"2008-06-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-06-14","scope":"DEMOLITION OF THE PHASE 1 SPACE ON THE 3RD FLOOR AS PER PLAN"},{"number":"167799","date":"2008-09-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-06-20","scope":"PHASE I RENOVATION"},{"number":"188571","date":"2008-11-17","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-04-01","scope":null},{"number":"189693","date":"2008-11-24","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-02-04","scope":"INSTALL (1) STAINLESS STEEL SINK"},{"number":"192261","date":"2009-01-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-07-14","scope":"WE ARE DOING WORK IN PHASE 1A. INSTALL 2 NURSE CALL DUTY STATIONS AND 2 DOME LIGHT. ALL RECEPTS ORIGINATE FROM EXISTING PANEL, NEW LIGHT FIXTURE TIED INTO EXISTING CIRCUITS AS PER 2005 NEC (EAST DISTRICT)FIRE ALARM WILL BE APPLIED FOR AT A LATER DATE"},{"number":"189667","date":"2009-01-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-06-14","scope":"RENOVATION TO EXISTING DUCTWORK & ADDING NEW GRD'S"},{"number":"198323","date":"2009-02-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-11-29","scope":"REPLACE 7 EXISTING FIRE DAMPERS WITH FIRE/SMOKE DAMPERS AND INSTALL TWO NEW FIRE SMOKE DAMPERS,AS PER PLANS. PROVIDE CLEARLY MARKED,LISTED AND LABELED ACCESS PANELS PER CODE. MUST MAINTAIN ALL CODE REQUIRED FIRE RATINGS. WORK TO COMPLY VIOLATION CASE # 169998."},{"number":"17720","date":"2009-03-18","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2009-03-18","scope":"3/18/09 - TENTS ERECTED ON SITE"},{"number":"206224","date":"2009-03-20","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-07-02","scope":null},{"number":"205065","date":"2009-03-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-10-15","scope":"INSTALL BOOSTER PANEL CONNECTED TO EXISTING FACP, INSTALL NEW STROBES, HORN/STROBES, SMOKE DETECTOR AND CONTROL MODULE FOR FIRE SMOKE DAMPER AS PER NFPA72 (EAST DISTRICT)"},{"number":"207986","date":"2009-03-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-05-21","scope":"FIXTURE REPLACEMENT"},{"number":"208334","date":"2009-04-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL NEW MDP TO EXISTING CIRCUIT, RE-USE EXISTING LT FIXTURES, BRANCH CIRCUITS TO ORIGINATE FROM EXISTING PANEL BOARD, INSTALL CONDUIT FOR GE SYSTEMS CABLE, WILL APPLY FOR A FA PERMIT ON A LATER DATE, AS PER 2005 NEC (EAST DIST)"},{"number":"214613","date":"2009-05-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-09-13","scope":"INSTALL (2) MONITOR MODULES AND (6) DUCT DET AND TEST SWITCHES FOR SMOKE DAMPERS, AS PER NFPA-72 (EAST DIST)"},{"number":"19071","date":"2009-05-12","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2009-05-12","scope":"5/13/09 - TENTS INSTALLED ON FRANKFORD HOSPITAL SITE"},{"number":"207972","date":"2009-05-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-06-01","scope":"DUCTWORK RENOVATIONS WITH SOME NEW & SOME RELOCATED GRD'S LOCATED ON THE 2ND FLOOR MRI SUITE. ALLWORK SHALLCOMPLY WITH THE APPROVED PLANS AND THE PHILADELPHIA CODE."},{"number":"215709","date":"2009-05-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-02","scope":"INSTALL BOOSTER PANEL, 2 SMOKE DETECTORS AND 1 STROBE, CONNECT CONTROL MODULE TO SHUTTER DOOR AS PER NFPA72 (EAST DISTRICT)"},{"number":"218521","date":"2009-06-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-08-17","scope":"RENOVATION OF EXISTING OPERATING ROOMS #1 THRU #7 IN PHASES. WORK TO INCLUDE NEW CEILINGS, FINISHES AND MECHANICAL, ELECTRICAL, AND MEDIC GAS UPGRADES AS PER PLAN."},{"number":"220365","date":"2009-06-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-09-13","scope":"INSTALL APPROX. 120 FLUORESCENT FIXTURES, 60 RECEPTS, 20 SWITCHES AND 15 - 60AMP PANELS AS 2005 NEC (EAST DISTRICT)"},{"number":"202912","date":"2009-07-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-07-07","scope":"ALTERATIONS/FIT OUT, STRUCTURAL MODIFICATIONS FOR NEW MRI SUITE IN EXISTING HOSPITAL, ROOF ALTERATIONS,AND AS PER ASSOCIATED MRI CONSTRUCTION STANDARDS AND SPECIFICATIONS, AS PER SUBMITTED PLANS."},{"number":"228264","date":"2009-08-06","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2009-08-06","scope":"ERECT TEN (10) EXISTING SIGNS, SIZE AND LOCATION AS SHOWN IN APPLICATION. SIGNS ACCESSORY TO AN EXISTING MEDICAL OFFICE BUILDING WITH USES AS PREVIOUSLY APPROVED AND EXISTING ACCESSORY PARKING."},{"number":"229103","date":"2009-08-06","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2010-02-05","scope":"REFACE SIGNS ALL DOUBLE SIDED FREESTANDING SIGNS AND ERECT NEW FLATWALL SIGN ON BUILDING AS PER PLAN."},{"number":"222187","date":"2009-08-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-08-17","scope":"MECHANICAL ALTERATIONS AS PER PLANS"},{"number":"232650","date":"2009-08-27","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2009-09-28","scope":"AMEND BLDG. PERMIT #229103 TO INCLUDE THE VIOLATION REINSPECTION FEE OF ONE FLATWALL SIGN."},{"number":"233690","date":"2009-08-27","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-02-22","scope":"ROOF REPLACEMENT, SINGLE-PLY (MEDICAL OFFICE BUILDING)"},{"number":"228742","date":"2009-09-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-10-06","scope":"EXTEND EXISTING SPRINKLER SYSTEM INTO OPERATING ROOM AREA ON THE THIRD FLOOR AS PER PLANS. EXISTING BACKFLOW SYSTEM."},{"number":"256913","date":"2010-02-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-08-22","scope":"MODIFY & EXTEND EXISTING SPRINKLER SYSTEM AND CONVERT DRY STANDPIPES TOP WET STANDPIPES AS PER PLANS."},{"number":"274060","date":"2010-04-21","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-06-14","scope":"INSTALL 3 TRACK LIGHTS, 8 SCONCE LIGHTS AND 2 FLOOR RECEPTACLES AS PER 2008 NEC (EAST DIST)"},{"number":"271449","date":"2010-04-27","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2010-06-02","scope":"AMEND PERMIT #173414 TO INCLUDE LAWFUL OCCUPANCY DETERMINATION FOR CAFETERIA"},{"number":"20419","date":"2010-05-27","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2010-05-27","scope":"5/26/10-ERECTION OF (2)-ASSEMBLY USE TENTS FOR HOSPITAL PICNIC"},{"number":"288471","date":"2010-07-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-09-13","scope":"THIS PERMIT IS BEING PROVIDED BECAUSE (3) ADDITIONAL SMOKE DAMPERS WERE ADDED TO THIS PROJECT. PLEASE REFERENCE OUR PERMIT #214613 DATE 5/12/09 FOR FURTHER DETAILS AS PER 2008 NEC (EAST DIST)"},{"number":"282109","date":"2010-07-19","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2010-11-29","scope":"AMEND PERMIT# 198323, ADDING THE INSTALLATION OF THREE ADDITIONAL FIRE/SMOKE DAMPERS AS SHOWN ON PLANS."},{"number":"302898","date":"2010-11-08","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"EXPAND EXISTING PARKING STUCTURE WITH A GARAGE ADDITION. CREATE ADDITIONAL DRIVEWAY ENTRANCE FROM KNIGHTS ROAD FOR HOSPITAL."},{"number":"308799","date":"2010-12-08","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2011-07-08","scope":"CONSTRUCT NEW OPEN PARKING GARAGE ADDITION, EXPANDING EXISTING OPEN PARKING GARAGE, ADDITIONAL SITE/CIVIL WORK FOR EXISTING HOSPITAL COMPLEX. NO NEW CURB CUTS."},{"number":"318511","date":"2011-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-07-08","scope":"INSTALLATION OF ABOVE GROUND INFILTRATION BASIN AND RELATED PIPING, INSTALL 3 REW'S AND 5 AREA DRAINS"},{"number":"321588","date":"2011-01-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-02-18","scope":"INSTALL 100AMP TEMPORARY SERVICE FOR 6 MONTHS AS PER 2008 NEC (EAST DISTRICT)"},{"number":"323723","date":"2011-02-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-02-18","scope":"RE-ROUTING OF EXISTING 6\" DRAINAGE PIPING TO ACCOMMODATE INSTALLATION OF BUILDING FOOTERS FOR PROPOSED PARKING GARAGE EXPANSION"},{"number":"322935","date":"2011-03-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-07-08","scope":"INSTALLATION OF NEW DRAIN FOR PARKING GARAGE, AND 62 FIXTURES"},{"number":"337973","date":"2011-05-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL POWER AND LIGHTING AS PER 2008 NEC (EAST DISTRICT)"},{"number":"340131","date":"2011-05-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-06-16","scope":"INSTALL 16 TAMPER SWITCHES AND 5 FLOW SWITCHES SECO JOB #1319 AS PER 2008 NEC"},{"number":"347593","date":"2011-06-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-09-06","scope":"PARKING GARAGE: PROVIDE ONE (1) PULL STATION AND (1) HORN/STROBE IN EACH STAIR TOWER (4), AS PER NFPA-72 (EAST DIST)"},{"number":"348833","date":"2011-06-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-07-08","scope":"INSTALL TWO NEW STANDPIPES AND CONNECT TO EXISTING MANUAL DRY SYSTEM."},{"number":"359861","date":"2011-08-24","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-03-20","scope":"REPLACE 30 FT OF MAIN SEWER LINE IN PARKING LOT PA1#2011234128"},{"number":"361024","date":"2011-08-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"EXPIRED","completedDate":null,"scope":"REPAIR SECTION OF MAIN HOUSE DRAIN PA1#20112741280"},{"number":"367988","date":"2011-10-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-12-12","scope":"ALTERATIONS TO REPLACE EXISTING STEREOTAXIS EP EQUIPMENT AND INTERIOR RENOVATIONS TO THE EP EQUIPMENT ROOM. NO CHANGES IN USE OR OCCUPANCY."},{"number":"369778","date":"2011-10-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-12","scope":"HVAC / DUCTWORK, 2ND FLOOR - STREOTAXIS EP / CATH LAB AS PART OF HOSPITAL. AR"},{"number":"370604","date":"2011-10-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-12-12","scope":"RELOCATING 11 SPRINKLER ON THE 2ND FLOOR IN STEREOTAXIS EP CATH OF ARIA HEALTH."},{"number":"371080","date":"2011-11-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-01-05","scope":"INSTALLATION OF HVAC, INCLUDING DUCTWORK, MECHANICALS FOR ALTERATIONS IN EXISTING HOSPITAL SAPCE"},{"number":"370621","date":"2011-11-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-02-01","scope":"INSTALL 4 DUPLEX RECEPTACLES, INSTALL 2 EPU BUTTONS, INSTALL DOOR CONNECTION, INSTALL POWER 2 AC UNITS, INSTALL PANEL IR HVAC, INSTALL 25 LIGHTS FIXTURES, NEW PANEL FEEDER, POWER FOR PHILLIP EQUIPMENT, AS PER 2008 NEC, HEALTH CENTER"},{"number":"368350","date":"2011-11-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-01-03","scope":"INSTALL NEW STEREOTAXIS EQUPIMENT AND REPLACE CATH LAB EQUIPMENT AS PER 2008 NEC (SECOND FLOOR ONLY, HEART CENTER, LAB #5)(EAST DISTRICT)"},{"number":"369771","date":"2011-11-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-01-05","scope":"RENOVATION OF AN INTERVENTIONAL RADIOLOGY ROOM WITH NEW FINISHES AND EQUIPMENT @ 2ND FLOOR."},{"number":"381869","date":"2012-01-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-02-03","scope":"REMOVE AND REINSTALL SINK IN SAME LOCATION CONNECT TO EXISTING SERVICES, HOSPITAL"},{"number":"381538","date":"2012-02-07","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2012-02-07","scope":"CONSTRUCT A 2ND AND 3RD FLOOR STORY ADDITION ATOP A 1 STORY PORTION OF AN EXISTING BLDG."},{"number":"388117","date":"2012-02-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-02-29","scope":"RELOCATE 20 SPRINKLER HEADS."},{"number":"388428","date":"2012-02-24","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-06-04","scope":"ALTERATIONS TO LOBBY SPACE WITHIN HOSPITAL"},{"number":"388490","date":"2012-03-07","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-06-14","scope":"ALL WORK IS REMOVE/REPLACE IN KIND: 47 LIGHT FIXTURES, 4 RECEPTACLES, 8 SMOKE DETECTORS & 11 P/A SPEAKERS. NO NEW CIRCUITRY 0R TELE/DATA ON THIS PERMIT."},{"number":"398306","date":"2012-04-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-05-29","scope":"REMOVE AND REINSTALL 6 TOILETS, 2 URINALS, 8 LAVS(HOSPITAL)"},{"number":"399593","date":"2012-05-17","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2012-06-05","scope":"AMENDING BLDG PERMIT#388428 TO REFLECT DRAWING CHANGES."},{"number":"400362","date":"2012-05-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-11-30","scope":"REPAIR AND REHABILITATION WORK TO AN EXISTING FOUR (4) TIER OPEN PARKING GARAGE PER PLANS; SPECIAL INSPECTIONS TO BE PERFORMED BY ENGINEER."},{"number":"401964","date":"2012-05-31","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2013-01-09","scope":"CONSTRUCT A 2ND AND 3RD FLOOR STORY ADDITION ATOP A 1 STORY PORTION OF AN EXISTING BLDG. BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMIT REQUIRED FOR M,E,P AND FIRE SUPPRESSION."},{"number":"412727","date":"2012-07-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-02-04","scope":"REPL EXIST 1500 KVA TRANS PROV & INST NH2L1 NL2L1 NL2L1-B EH2L1 EL2L1 PANEL BOARDS PROV & INST 45 KVA & 30 KVA TRANS PROV & INST HEAT TRACE PROV & INST POWER & LIGHT AS SHOWN ON DRAWINGS AS PER NEC 2008 & NPFA 72"},{"number":"413960","date":"2012-08-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-01-09","scope":"NEW DOMESTIC WATER PIPING, SANITARY & STORM INSIDE NEW ADDITION"},{"number":"418273","date":"2012-08-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-09-13","scope":"INTERIOR ALTERATIONS TO CREATE A NEW RADIOLOGY ROOM AS PER PLANS."},{"number":"419753","date":"2012-08-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-10-02","scope":"HVAC AS PER PLAN. SEE AP#418273 FOR PLANS."},{"number":"414349","date":"2012-08-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-01-09","scope":"INSTALL DUCTWORK, REGISTERS, DIFFUSERS, MECHANICAL UNITS."},{"number":"420740","date":"2012-08-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-03-12","scope":"ADDITION OF 1 NEW SINK"},{"number":"422400","date":"2012-08-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-09-05","scope":"RELOCATE 3 SPRINKLER HEADS, 1ST FLOOR RADIOLOGY"},{"number":"418913","date":"2012-08-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-09-18","scope":"RENOVATION OF R & F ROOM #4 INCLUDING LIGHT FIXTURES, RECEPTACLES, NURSE CALL DEVICES, DOOR SWITCHES, AND CONDUITS PER 2008 NEC"},{"number":"418965","date":"2012-09-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-01-09","scope":"EXTEND EXISTING SPRINKLER SYSTEM FOR ONGOING RENOVATIONS"},{"number":"420001","date":"2012-09-10","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2012-09-10","scope":"1. COMPLETE THE FOLLOWING, IN ACCORDANCE W/SUBMITTED DRAWINGS ZSP-1 & IDD-1 BY BARRY ISETT & ASSOCIATES, INC & ZP-1 & ZP-2 BY FRANCIS CAUFFMAN, INC A. DEMOLISH PORTIONS OF THE EXISTING HOSPITAL BLDG (BLDG \"G\" & PORTIONS OF BLDG \"A\") B. CONSTRUCT A 3 STY, EMERGENCY DEPT ADDITION (BLDG \"I\"). C. CONSTRUCT A 1 STY, DETACHED, MAINTENANCE GARAGE (BLDG \"J\"), MECHANICAL COOLING TOWERS, ELECTRICAL SUBSTATION, EMERGENCY GENERATOR, RETAINING WALL RECONSTRUCTION, INTER ALIA. D. RECONFIGURE/RECONSTRUCT EXISTING, OFF-STREET PARKING AREA NOS. \"3\", \"4\", \"5\", \"7\" & \"8\". 2. NO CHANGE IN THE EXISTING USE OR SIGNAGE."},{"number":"434842","date":"2012-10-25","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-02-10","scope":"RELOCATE (10) EXISTING SPRINKLER HEAD - EMERGENCY DEPT."},{"number":"430724","date":"2012-11-02","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2012-12-11","scope":"NEW CONSTRUCTION OF A (1) STORY GARAGE."},{"number":"432413","date":"2012-11-07","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2012-11-07","scope":"TEMP BIO MED BLDG. CONSTRUCT A TEMP ONE STORY DETACHED MODULAR OFFICE BLDG. RELOCATE EXISTING ADA PARKING SPACE AND INSTALL CANOPY ON BLDG"},{"number":"437715","date":"2012-11-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-12-11","scope":"NEW STORAGE GARGAGE FOR ARIA HEALTH (PLUMBING CONSTRUCTION) - (1)1-1/2\" LAUNDRY TRAY AND (1)30GALLON DOMESTIC HOT WATER HEATER - NOTE: STORM DRAINAGE IS NOT A PART OF THIS PERMIT - THE 4\" HOUSE DRAIN CONNECTS TO AN EXISTING MANHOLE THROUGH A 5\" HOUSE TRAP (PRIVATE SEWER ON SITE) - WATER DISTRIBUTION CONNECTS TO AN ONSITE PRIVATE WATER MAIN"},{"number":"437845","date":"2012-11-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 100 AMP SERVICE, 10-RECPT, 2-SW, 8-LGT FIXTURES, POWER TO 3 HEATERS, POWER TO AIR COMPRESSOR & POWER TO WATER HEATER AS PER NEC 2008 (GARAGE/SHED)"},{"number":"436566","date":"2012-11-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-02-10","scope":"DOMESTIC WATER AND SANITARY PIPING TO NEW FIXTURES IN RENOVATED AREA"},{"number":"436791","date":"2013-01-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-02-10","scope":"PARTIAL DEMOLITION AND INSTALLATION OF NEW DUCT WORK WITH ASSOCIATED REGISTERS / GRILLES / DIFFUSERS IN A PORTION OF THE FIRST FLOOR PER PLAN."},{"number":"439524","date":"2013-01-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-03-07","scope":"TEMPORARY RENOVATIONS TO EMERGENCY DEPT TO FACILITATE NEW EMERGENCY DEPT CONSTRUCTION - 3 FIRE ALARM DEVICES RELOCATED FOR TEMOPRARY USE - AS PER NFPA 72 AND 2008 ELECTRICAL CODE"},{"number":"437800","date":"2013-01-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-02-10","scope":"FOR LEVEL II ALTERATIONS TO INCLUDE THE CREATION OF AN EXTERIOR OPENING FOR USE AS ENTRANCE TO TEMPORARY EMERGENCY DEPARTMENT, WITH THE INFILL OF EXTERIOR WINDOWS. INTERIOR RENOVATIONS TO INCLUDE DEMOLITION AND ERECTION OF PARTITION WALLS ON FIRST FLOOR IN SPECIFIED AREA AS SHOWN ON APPROVED PLANS. WORK TO ALSO INCLUDE THE ERECTION OF A PRE-FABRICATED CANOPY. ALL WORK SHALL BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR SIGNAGE, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK."},{"number":"455600","date":"2013-03-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-12-08","scope":"INSTALL 2 SURFACE STORM WATER INFILTRATION MNGMT FACILITES INCL 25 STORM WATER INLETS & PIPING TO 5 RAINWATER CONDUCTORS TO WITHIN 5' FROM BLDG, STORM SYSTEM TO DISCHARGE TO EXISTING STORM PIPING ON PROPERTY (HOSPTIAL)"},{"number":"453941","date":"2013-04-11","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2014-12-08","scope":"ERECTION OF AN ADDITION TO AN EXISTING BLDG. 2 CANOPY ENTRANCES, 2 STAIR TOWERS, 1 ELEVATOR. AS PER PLANS-HOSPITAL. SEPARATE PERMIT IS REQUIRED FOR THIRD STORY FIT-OUT."},{"number":"459202","date":"2013-04-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-08-17","scope":"INST DUCT BANKS 15KV PECO APPROVED SERV SW GEAR,1-8'X8'X6'MANHOLE CHANGEOVER OF 11-13,200V TO 480V EX SFMRS TO FEED, INST OWNER SUPP DIESEL GEN SET PROV SITE LGT FROM PNL SLP ON DRAW E301 AS PER NEC 2008"},{"number":"457481","date":"2013-04-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-07-09","scope":"CONNECT 2-8\" & 1-3\" SANI PIPE TO EXTEN 5'-0\" FROM PROPOSED BLDG ADD, INSTALL INCLUDES 2-8\" H/TRAPS & 1-5\" H/TRAP W/ PRVB'S TO FINISH GRADE, SEE ATTACH ENGINEERS CALUCLATION SHEET (HOSPITAL)"},{"number":"474056","date":"2013-07-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-07-09","scope":"INSTALLATION OF NEW HVAC SYSTEM FOR HOSPITAL ADDITION AS PER APPROVED PLANS."},{"number":"475841","date":"2013-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-07-09","scope":"NEW DEOMESTIC WATER PIPING, SANITARY, WASTE & STORM FOR NEW ADDITION & RENOVATION (HOSPITAL)"},{"number":"491802","date":"2013-10-15","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2014-07-09","scope":"FOR THE INSTALLATION OF ONE (1) 15,000 GALLON HEATING OIL UNDERGROUND STORAGE TANK (UST). ALL WORK TO BE DONE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. SIZE AND LOCATION AS SHOWN PER APPROVED PLANS."},{"number":"498905","date":"2013-12-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-07-09","scope":"INSTALLATION OF SPRINKLERS IN THE FIRST THROUGH THIRD FLOORS IN ACCORDANCE WITH NFPA 13 (HOSPITAL). THIS IS AN EXTENSION OF AN EXISTING SPRINKLER SYSTEM WITH AN EXISTING BACKFLOW PREVENTION DEVICE (6\" AMES 2000SS) AT THE FIRST FLOOR VALVE ROOM. ALL WORK SHALL BE PER PLANS APPROVED BY THE PENNSYLVANIA DEPARTMENT OF HEALTH (H-13-1367)."},{"number":"478030","date":"2013-12-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"BLDG ADD TO EMER DEPARTMENT, NORMAL, EMER ELEC SERV & DIST, BRANCH WIRE, WIRE DEV, LGT FIX & MECH EQUIP CONNECTION, CATV SYSTEM WIRING EXTENSION OF EXIST F/A, F/A DRAWING TO FOLLOW AS PER NEC 2008 & NFPA 72 (HOSPITAL)"},{"number":"527441","date":"2014-05-19","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-05-19","scope":"SIGNAGE FOR ARIA HOSPITAL."},{"number":"534561","date":"2014-06-09","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-06-09","scope":"FOR THE REMOVAL OF NINE (9) EXISTING FREE-STANDING SIGNS AND THE ERECTION OF SIX (6) DOUBLE-FACED, STATICALLY ILLUMINATED FREE-STANDING SIGNS AND THE REFACING OF ONE (1) EXISTING DOUBLE-FACED, STATICALLY ILLUMINATED FREE-STANDING SIGN. SIZE AND LOCATION AS SHOWN IN APPLICATION. FOR USE AS SIGNS ACCESSORY TO AN EXISTING HOSPITAL."},{"number":"537817","date":"2014-06-09","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2014-09-18","scope":"ERECTION OF THREE (3) ACCESSORY FLATWALL SIGNS (SIZE AND LOCATION AS SHOWN ON PLANS)."},{"number":"547895","date":"2014-07-08","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-08-19","scope":"ADD WASTE & WATER FOR 2-EXAM SINKS, PUMP WASTE (HOSPITAL)"},{"number":"547084","date":"2014-07-14","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-07-14","scope":"TEMPORARY C O FOR PERMIT 453941"},{"number":"545884","date":"2014-07-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-08-19","scope":"FOR LEVEL II ALTERATION TO AN EXISTING OFFICE ON THE SECOND FLOOR OF AN EXISTING HEALTH FACILITY. ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS WITH FINSIHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPRESSION WORK."},{"number":"541745","date":"2014-07-22","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2014-09-12","scope":"FOR THE REMOVAL OF NINE (9) EXISTING FREE-STANDING SIGNS AND THE ERECTION OF SIX (6) DOUBLE-FACED, STATICALLY ILLUMINATED FREE-STANDING SIGNS AS PER PLANS."},{"number":"550623","date":"2014-07-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-11-13","scope":"INSTALL (11) DUPLEX RECEPTACLES AND (5) DUPLEX GFI RECEPTACLES TO EXISTING ROOM... IN ACCORDANCE WITH 2008 NEC"},{"number":"597125","date":"2015-03-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-08-29","scope":"PROVIDE RECEPTS AND BRANCH CIRCUIT WIRING,PROVIDE POWER WIRING FOR HVAC AND HOSPITAL EQUIPMENT,PROVIDE NEW ELECTRIC PANELS AND PANEL FEEDERS,EXCLUDES FIRE ALARM,SECURITY ALARM,PHONE,DATA,SOUND,PAGING,AND LOW VOLT WIRING IN ITS ENTIRETY AS PER 2008 NEC (EAST DISTRICT)"},{"number":"591078","date":"2015-03-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-07-02","scope":"ALTERATIONS OF AN EXISTING MEDICAL FACILITY INCLUDING THE REMOVAL AND RE-INSTALLATION OF AN EXISTING SKYLIGHT (TO ACCOMMODATE THE INSTALLATION OF NEW MEDICAL EQUIPMENT). ALL WORK PER DOH APPROVED PLANS AND ENGINEER'S REPORT. SEPARATE PERMIT REQUIRED FOR FIRE SUPPRESSION, MECHANICAL, ELECTRICAL AND PLUMBING."},{"number":"596919","date":"2015-04-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-07-02","scope":"INSTALLATION OF HVAC MECHANICAL SYSTEM, EQUIPMENT, DUCT WORK, PIPING,"},{"number":"616013","date":"2015-06-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL LOW VOLTAGE CABLES FOR NEW LINEAR ACCELERATOR EQUIPMENT FOR VOICE, DATA, AND EQUIPMENT CONTROLS AS PER 2008 NEC. (EAST DISTRICT)"},{"number":"640093","date":"2015-10-29","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2022-06-14","scope":"INSTALLATION OF AN EXTERIOR STRUCTURAL CONCRETE SLAB FOR A NEW GENERATOR AS PER APPROVED PLANS."},{"number":"23924","date":"2015-11-28","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2015-11-28","scope":"6/11/15 - ERECT 2 ASSEMBLY TENTS (40'X 50') AND (30'X 90') AT ARIA HEALTH FRANKFORD TORRESDALE HOSPITAL"},{"number":"649244","date":"2015-12-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-11","scope":"FOR THE INSTALLATION OF A COMBINED HEAT AND POWER COGENERATION PLANT TO INCLUDE INTERCONNECTION OF REFRIGERANT PIPING FROM BOILER ROOM TO COGENERATION PLANT."},{"number":"646322","date":"2016-01-08","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-06-14","scope":"CONNECT OWNER SUPLLIED 1.1 MW GENERATOR, PARALLELLING BREAKER AND TRANSFORMER TO THE EXISTING MAIN SWITCHGEAR; PROVIDE BRANCH POWER TO COGEN UNIT AS PER 2008 NEC (EAST DISTRICT)"},{"number":"665283","date":"2016-02-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-01-16","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO THIRD FLOOR ICU UNIT WITHIN AN EXISTING HOSPITAL AS PER APPROVED PLANS AND PA DOH APPROVALS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"24141","date":"2016-04-22","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2016-04-22","scope":"5/11/16 ERECT ASSEMBLY TENT (1)30X90, (1)40X50"},{"number":"24317","date":"2016-07-05","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2016-07-05","scope":"7/5/16 ERECT ASSEMBLY TENT 20X50"},{"number":"691128","date":"2016-07-20","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2016-07-20","scope":"ADDITION TO BUILDING IN THE COURTYARD FOR COFFEE SHOP (EXISTING HOSPITAL)"},{"number":"691125","date":"2016-07-20","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2016-10-24","scope":"PARTIAL DEMOLITION OF EXISTING ALUMINUM / GLAZING EXT. WALL AT BUILDING COURTYARD AREA. INSTALLATION OF NEW REINFORCED CONCRETE SPREAD FOOTINGS AND PRE-MANUFACTURED GLAZING / ENCLOSURE WALL AND ROOF SYSTEM ADDITION WITH ALL ASSOCIATED INTERIOR FINISHES FOR NEW CAFE / COFFEE SHOP IN HOSPITAL. **ALL WORK IN ACCORDANCE WITH PA DEPT. OF HEALTH APPROVED PLANS H-16-0464; ALL SPECIAL INSPECTION REPORTS SHALL BE FURNISHED TO FIELD INSPECTOR** SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"694441","date":"2016-07-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 12 GFI RECEPT 1 JUNCTION BOX POWER 1-208V RECET, POWER FOR HEAT PUUMP, ELECTIRC HAT, 6 LIHGT FIXTURES AND 2 SWITCHES AS PER 2008 NEC (EAST DISTRICT)"},{"number":"686018","date":"2016-07-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-02-01","scope":"INSTALLATION OF CLEAN AGENT FIRE SUPPRESION SYSTEM IN HUT. INCLUDES TANK, NOZZLE, CONTROL PANEL AND ALL FIELD DEVICES."},{"number":"715849","date":"2016-08-18","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-10-17","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"711026","date":"2016-09-21","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-10-24","scope":"ALTERATION: INTERIOR PLUMBING; COFFEE SHOP ADDITION IN COURTYARD - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"740215","date":"2017-01-05","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-06-14","scope":"INSTALL 30KVA TRANSFORMER,60AMP DISC SWITCH,1-EMON METER,100AMP 30 CIRCUIT 120/208V PANEL,1-2\"CONDUIT FROM 1ST FLOOR TO 4TH FLOOR ROOF,POWER TO 1-ROOF TOP CONDENSER AND POWER TO 1-AIR HANDLER AS PER 2008 NEC (EAST DISTRICT)"},{"number":"741282","date":"2017-01-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-01-19","scope":"FOR THE INSTALLATION OF A TWO (2) TON, WALL-MOUNTED DUCTLESS SYSTEM IN AN EXISTING STRUCTURE. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS."},{"number":"743814","date":"2017-01-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-15","scope":"FOR MECHAINICAL ALTERATIONS TO EXISTING STRUCTURE TO INLCUDE REPLACEMENT OF RTU-2 WITH ASSOCIATED DUCTWORK AT SECOND LEVEL AND ROOF, AS PER APPROVED PLANS."},{"number":"765604","date":"2017-04-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-11","scope":"INSTALL NEW FEEDER FOR NEW HVAC EQUIPMENT.INSTALL POWER FOR UV LIGHTING REEFED HUMIDIFIER CIRCUITS (HEALTH CARE)"},{"number":"778358","date":"2017-04-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-03-09","scope":"TAKE DOWN AND REINSTALL APPRX 42 2X2 LAYIN AND HIT HAT 6\" NEW LIGHTS(REPLACEMENT OF EQUIPMENT NO NEW WIRING )PER 2008 NEC (HEALTH CARE)"},{"number":"24855","date":"2017-05-11","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2017-05-11","scope":"5/10/17 ERECT ASSEMBLY TENT 40X50, 40X100"},{"number":"791328","date":"2017-06-30","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-22","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"788242","date":"2017-06-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-01-22","scope":"FOR LEVEL II ALTERATION TO THE SECOND FLOOR OF AN EXISTING HEALTH FACILITY. ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS WITH FINSIHES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPRESSION WORK. PLANS PREVIOUSLY APPROVED BY HEALTH DEPARTMENT UNDER #H17-0275."},{"number":"799762","date":"2017-07-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-01-22","scope":"RELOCATE 15 EXISTING SPRINKLER HEADS"},{"number":"796377","date":"2017-08-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-22","scope":"FURNISH AND INSTALL NEW LIGHTS, SWITCHES, RECEPTS, NEW SERVICE FOR TOPO MAMMO MACHINE FROM EXISTING PANELS AS PER 2008 NEC (EAST DISTRICT) NO FIRE ALARM ON THIS PERMIT"},{"number":"803557","date":"2017-08-08","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-01-22","scope":"ALTERATION: INTERIOR PLUMBING; 2ND FLOOR; HEALTH CARE FACILITY; INSTALL 1-WATER CLOSET, 1-LAV SINK, 1-COUNTER SINK, 1-CLINICAL SINK AND 3-HAND SINKS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004"},{"number":"770181","date":"2017-08-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-01-30","scope":"FOR LEVEL II INTERIOR ALTERATIONS TO UPDATE THE LOBBY OF AN EXISTING HOSPITAL. WORK TO INCLUDE INTERIOR NON-BEARING PARTITIONS, MILLWORK, AND FINISHES. BUILDING SHALL BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS. ** ALL ASBESTOS TO BE TREATED & REMOVED PRIOR TO COMMENCEMENT OF WORK. **"},{"number":"805068","date":"2017-09-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-01-30","scope":"FOR LEVEL II EXTERIOR ALTERATIONS TO AN EXISTING HOSPITAL AS PER PLANS AND PA DOH APPROVAL; NEW ADA ACCESSIBLE RAMP, AND SITE IMPROVEMENTS AT ENTRANCE TO MEDICAL OFFICE BUILDING (MOB) AS PART OF ARIA HEALTH-TORRESDALE CAMPUS; NO OTHER WORK ON THIS PERMIT; SEPARATE PERMITS REQUIRED FOR ELECTRICAL WORK."},{"number":"811419","date":"2017-09-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FAI NEW FA 1 NAC PANEL 8 HORN/STROBE AND 4 STROBES"},{"number":"823823","date":"2017-10-13","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-01-30","scope":"PERMIT SPRINKLER RELOCATION (NFPA 13) - FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. RELOCATE 12 SPRINKLER HEADS."},{"number":"859516","date":"2018-03-29","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-10-26","scope":"FOR LEVEL II ALTERATION TO THE SECOND FLOOR OF AN EXISTING HEALTH FACILITY TO RELOCATE ULTRA SOUND TO THE GENERAL RADIOLOGY AREA. ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS WITH FINSIHES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPRESSION WORK. PLANS PREVIOUSLY APPROVED BY HEALTH DEPARTMENT UNDER #H17-0928."},{"number":"863597","date":"2018-04-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-09-20","scope":"NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. INTERIOR ALTERATIONS (PRESCRIPTIVE METHOD) AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK. ALL WORK SHALL BE IN ACCORDANCE WITH DOH APPROVAL."},{"number":"860512","date":"2018-04-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-07-10","scope":"FOR LEVEL II ALTERATIONS (NON-LOAD-BEARING PARTITION WALLS, FINISHES, NO STRUCTURAL WORK), WITHIN SUITE 206 (GROUP B MEDICAL OFFICES; NO CHANGE OF OCCUPANCY), ON THE SECOND FLOOR OF AN EXISTING HOSPITAL BUILDING, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING IS FULLY SPRINKLERED; NO SIGNS ON THIS PERMIT; NO WORK WITHIN PA-DOH-REGULATED AREAS."},{"number":"874354","date":"2018-05-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-09-20","scope":"RELOCATE 7 HEADS IN CHEST XRAY. FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"865143","date":"2018-05-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-12-21","scope":"FURNISH AND INSTALL NEW LIGHTS, SWITCHES & RECEPTACLES ON EXISTING PANELS AND SERVICE AS PER 2008 NEC (EAST DISTRICT)"},{"number":"25513","date":"2018-05-11","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2018-05-11","scope":"ERECTION OF TWO(2) TENTS (40' X 50', 40' X 100'). ASSEMBLED ON 5/9/18. OCCUPIED AND DISASSEMBLED 5/10/18."},{"number":"867286","date":"2018-05-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL 5 SMOKE DETECTRORS ONTO EXISTING FIRE ALARM SYSTEM AS PER NFPA72 (EAST DISTRICT)"},{"number":"865161","date":"2018-05-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-10-25","scope":"INSTALLATION OF HVAC SYSTEM ON 2ND FLOOR (ULTRASOUND RADIOLOGY) AS PER APPROVED PLANS."},{"number":"865146","date":"2018-06-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-12-21","scope":"INSTALL 13 PLUMBINGS FIXTUES WITH PIPING FOR HOSPITAL FIT OUT. INSTALLATIONS IN ACCORDANCE WITH 2004 PPC"},{"number":"885348","date":"2018-06-13","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-12-21","scope":"RELOCATE (32) EXISTING SPRINKLER HEADS. (COMMERCIAL)"},{"number":"881769","date":"2018-06-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-09-20","scope":"INSTALL 1 NEW HAND SINK WITH PIPING INSTALL 1 NEW PUMP FOR SINK TYING INTO EXISTING SANITARY AND WATER SYSTEM"},{"number":"885685","date":"2018-06-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-12-24","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"879580","date":"2018-06-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-09-13","scope":"FOR LEVEL II ALTERATION TO THE GROUND FLOOR OF AN EXISTING HEALTH FACILITY. ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS WITH FINSIHES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND FIRE SUPRESSION WORK."},{"number":"888591","date":"2018-06-25","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-07-10","scope":"INSTALL (1)WATER CLOSET, (1)LAV SINK AS PER PHILADELPHIA 2004 PLUMBING CODE."},{"number":"883839","date":"2018-07-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-09-20","scope":"MODIFY HVAC SYSTEM FOR CHEST X-RAY ROOM ON SECOND FLOOR OF EXISTING BUILDING AS PER APPROVED PLANS."},{"number":"872284","date":"2018-07-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-09","scope":"CHEST X-RAY ROOM EQUIPMENT REPLACEMENT, 16-LIGHT FIXTURES, 14-RECEPTACLES, 1-ENCLOSED CIRCUIT BREAKER, MAIN CONTROL PANEL EQUIPMENT CONNECTION AS PER NEC EAST DISTRICT"},{"number":"890077","date":"2018-08-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-09","scope":"RELOCATION OF 2-LIGHTS AND ADD 7-OUTLETS ONLY ON AN EXISTING SERVICE AS PER 2008 NEC (EAST DISTRICT)"},{"number":"26270","date":"2019-05-06","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2019-05-06","scope":"ERECTION OF TWO(2) TENTS (40' X 50', 40' X 100'). ASSEMBLED ON 5/15/19. OCCUPIED AND DISASSEMBLED 5/16/19."},{"number":"944368","date":"2019-05-16","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-05-16","scope":"FOR THE INSTALLATION OF ROOFTOP ANTENNAS AND EQUIPMENT CABINETS COLLOCATION OF 9 PANEL ANTENNAS AND EQUIPMENT ON THE EXISTING ROOFTOP. FOR USE AS WIRELESS SERVICE FACILITY (BUILDING OR TOWER MOUNTED ANTENNA) ANTENNAS SHALL BE PAINTED TO MATCH EXISTING STRUCTURE. ANTENNAS WILL NOT EXTEND MORE THAN 15 FEET ABOVE THE EXISTING ROOF LINE ON THE SAME LOT AS PREVIOUSLY APPROVED MEDICAL FACILITY"},{"number":"979379","date":"2019-07-12","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-02-03","scope":"INSTALLATION OF A WIRELESS TELECOMMUNICATIONS FACILITY ON THE ROOFTOP OF A HOSPITAL BUILDING CONSISTING OF 9 ANTENNAS AND EQUIPMENT AS PER APPROVED PLANS. ANTENNAS TO BE PAINTED TO MATCH EXISTING STRUCTURE. **SEPARATE PERMITS REQUIRED FOR WORK**"},{"number":"994381","date":"2019-08-20","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-22","scope":"100 AMP SERVICES FROM EXISTING MAIN PANELS 50 KW TRANSFORMER 200 AMP SERVICE 200 AMP PANEL 8-30 AMP RECTIFIERS, 2 MAINTENANCE LIGHTS, 1 RECEPTACLES, 1 SWITCH AS PER 2017 NEC (EAST DIST)"},{"number":"843003","date":"2019-08-23","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-08-23","scope":"FOR THE REMOVAL OF THIRTEEN (13) FREE-STANDING SIGNS AND TWO (2) FLAT-WALL SIGNS AND THE INSTALLATION OF SIX (6) DOUBLE-FACE, STATICALLY ILLUMINATED FREE-STANDING SIGNS [SIGNS 1, 3 & 5 THROUGH 8], TWO (2) SINGLE-FACE, STATICALLY ILLUMINATED FREE-STANDING SIGNS [SIGNS 2 & 4], TWO (2) DOUBLE-FACE, NON-ILLUMINATED FREE-STANDING SIGNS [SIGNS 9 & 12), TWO (2) SINGLE-FACE, NON-ILLUMINATED FREE-STANDING SIGNS [SIGNS 10 & 11] AND TWO (2) STATICALLY ILLUMINATED FLAT-WALL SIGNS [SIGNS 13 & 14]. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS. FOR USE AS SIGNAGE ACCESSORY TO AN EXISTING HOSPITAL."},{"number":"1009605","date":"2019-10-10","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-10-10","scope":"FOR THE ERECTION OF AN ENTRANCE ADDITION AS PART OF AN EXISTING STRUCTURE ON THE LOT. SIZE AND LOCATION AS SHOWN ON THE APPLICATION. USE: FOR EXISTING HOSPITAL FACILITY WITH ACCESSORY PARKING AND USES AS PREVIOUSLY APPROVED."},{"number":"1019750","date":"2019-10-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-01-03","scope":"NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. ALL WORK SHALL BE IN ACCORDANCE WITH DOH APPROVAL. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK."},{"number":"1019754","date":"2019-10-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-01-15","scope":"NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. ALL WORK SHALL BE IN ACCORDANCE WITH DOH APPROVAL. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK."},{"number":"1026917","date":"2019-11-13","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-12-07","scope":"INSTALL FLOOR DRAIN IN EQUIPMENT AS PER 2004 PPC"},{"number":"1024061","date":"2019-11-15","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-08-07","scope":"NO CHANGE OF USE AND OCCUPANCY. LEVEL II ALTERATIONS WITHIN THE FIRST FLOOR OBSERVATION SUITE TO INCLUDE NEWLY CONFIGURED TOILET ROOMS, NURSE STATIONS AND OFFICE ROOM AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING."},{"number":"1019334","date":"2019-11-19","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2020-07-27","scope":"FOR THE ERECTION OF An ENTRANCE ADDITION AS PART OF AN EXISTING STRUCTURE AND INTERIOR FIT OUT OF AN EXISTING 3RD FLOOR SHELL SPACE AS PER APPROVED PLANS. ALL WORK SHALL BE IN ACCORDANCE WITH DOH APPROVAL. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK."},{"number":"1031227","date":"2019-11-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-15","scope":"RELOCATE 2 DIFFUSERS IN RADILOGY.NO WORK TO EITHER DESIGNATED HISTORIAL STRUCTURE."},{"number":"1032353","date":"2019-12-04","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-03-02","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"1022243","date":"2019-12-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-02-21","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) ON THE SECOND FLOOR OF AN EXISTING HOSPITAL (MAIN BUILDING) TO CREATE AN IR LAB(IR LAB NUMBER 3) AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"1031226","date":"2019-12-10","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-01-04","scope":"FOR THE INSTALLATION OF APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTUER'S SPECIFICATION. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"1031205","date":"2019-12-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-29","scope":"FOR THE INSTALLATION OF REGISTER, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK FOR AN EXISTING HEALTH FACILITY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTUER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"1023997","date":"2019-12-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-15","scope":"FURNISH AND INSTALL NEW LIGHTS, SWITCHES, RECEPTACLES AND EXHAUST FAN **BUILDING PERMIT# 1019754**"},{"number":"1024005","date":"2019-12-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-03","scope":"FURNISH AND INSTALL (2) NEW 2X2 LIGHTS, (2) RECEPTACLES AND (1) SPLIT HEAT PUMP AS PER 2017 NEC.**BUILDING PERMIT# 1019750**"},{"number":"1027029","date":"2019-12-17","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-01-04","scope":"FOR THE INSTALLATION OF HVAC APPLIANCES, REGISTER, DIFFUSERS AND ASSOCIATED DUCTWORK FOR AN EXISTING HEALTH FACILITY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTUER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"1032316","date":"2019-12-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2020-01-31","scope":"FURNISH AND INSTALL 3 WATER CLOSET, 4 LAVATORIES, 2 SHOWERS, 2 SINKS, 2 FLOOR DRAINS WITH TRAY PRIMERS PER 2018 PHILA PLUMBING CODE"},{"number":"1029522","date":"2019-12-23","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-08-27","scope":"FURNISH AND INSTALL NEW LIGHTS, SWITCHES AND RECEPTACLES"},{"number":"1028880","date":"2020-01-03","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-07-17","scope":"NEW 14,000 SF CENTER CENTER ON THE 3RD FR SHELL SPACE. NEW DOMESTIC WATER, SANITARY WASTE, VENT, AND STORM WATER PIPING"},{"number":"1038953","date":"2020-01-06","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-01-28","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"1038965","date":"2020-01-06","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-08-07","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"1038361","date":"2020-01-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-21","scope":"F&I NEW LIGHTS, SWITCHES, RECEPS BACK TO EXISTING PANELS"},{"number":"1044104","date":"2020-02-07","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"FURNISH AND INSTALL (4) STROBES IN EXISTING FA LOOP AS PER NFPA 72."},{"number":"1043727","date":"2020-02-20","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-09-29","scope":"FOR ALTERATIONS TO REPLACE THE ROOF COVERING WITH LUDOWICI TILES IN ACCORDANCE WITH APPROVED PLANS REVIEWED BY THE HISTORICAL COMMISSION, TO INCLUDE WATERPROOF UNDERLAYMENT AND MODIFIED BITUMEN MEMBRANES. COPPER FLASHING TO MATCH EXISTING HISTORICAL FEATURES, WITH NEW TILE TO MATCH EXISTING TILE IN SIZE, STYLE, AND COLOR. MASONRY CLEANING WORKTO BE APPLIED UNDER LOW PRESSURE WASH TO AVOID DAMAGING HISTORICAL MASONRY. ALL BRICK MASONRY NOT TO BE WATERPROOFED"},{"number":"1029526","date":"2020-03-06","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-07-14","scope":"FURNISH AND INSTALL NEW SITE LIGHTS/SWITCHES RECEPTACLES AND LIGHTS AS PER 2017 NEC. (NORTH DISTRICT)"},{"number":"1055605","date":"2020-03-06","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-07-27","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"1035856","date":"2020-03-10","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2020-07-17","scope":"INSTALLATION OF HVAC SYSTEM ON THIRD FLOOR OF EXISTING BUILDING AS PER APPROVED PLANS. ** 2018 IMC **"},{"number":"1036708","date":"2020-04-20","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-07-14","scope":"F&I NEW SMOKE DETECTOR STROBES PULL STATIONS, HORNS & DOOR DETECTORS PANEL"},{"number":"1051398","date":"2020-06-26","work":"Amend for conversion","type":"Administrative","description":"Administrative Permit","status":"Issued","completedDate":null,"scope":"NEW 14,000 SF CENTER CENTER ON THE 3RD FR SHELL SPACE. NEW DOMESTIC WATER, SANITARY WASTE, VENT, AND STORM WATER PIPING."},{"number":"EP-2020-002694","date":"2020-07-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-10-23","scope":"Install 81 Duplex Outlets Install 240 Cat 5 e Cables not longer than 150 ft . All work to be done according to the 2017 NEC ."},{"number":"EP-2020-010270","date":"2020-12-05","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-08-13","scope":"Install 8 Fixtures - 2 Receptacles - 3 Switches - X-Ray In Use Light- Reinstall Existing Smoke Detector - Rework Walker Duct and Disconnect as per 2017 NEC"},{"number":"CP-2020-006209","date":"2021-01-12","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-09-14","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO A PORTION OF THE 2ND FLOOR OF AN EXISTING HOSPITAL BUILDING (RADIOLOGY DEPARTMENT). ALL WORK TO BE PERFORMED AS PER APPROVED PLANS AND PA DOH APPROVALS. EXISTING BUILDING FULLY SPRINKLERED**SEPARATE PERMITS REQUIRED FOR ANY MECHANICAL,ELECTRICAL AND PLUMBING OR FIRE SUPPRESSION WORK**"},{"number":"MP-2021-000236","date":"2021-01-13","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-03-23","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO A PORTION OF THE 2ND FLOOR OF AN EXISTING HOSPITAL BUILDING (RADIOLOGY DEPARTMENT). ALL WORK TO BE PERFORMED AS PER APPROVED PLANS AND PA DOH APPROVALS. EXISTING BUILDING FULLY SPRINKLERED**SEPARATE PERMITS REQUIRED FOR ANY MECHANICAL,ELECTRICAL AND PLUMBING OR FIRE SUPPRESSION WORK**"},{"number":"FP-2020-002404","date":"2021-01-15","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-03-23","scope":"We will be relocating (1) sprinkler at Jefferson Torresdale Radiology Room 2nd floor."},{"number":"EP-2021-002134","date":"2021-05-26","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-07-30","scope":"Install two 400 amp feeders, disconnect and circuit breaker for emergency chiller feeder as per 2017 NEC"},{"number":"ZP-2022-000950","date":"2022-03-02","work":"New construction, addition, GFA change","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"FOR THE ERECTION OF A CANOPY STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS."},{"number":"CP-2022-004021","date":"2022-07-21","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-09-26","scope":"FOR LEVEL 2 ALTERATIONS OF AN EXISTING HOSPITAL AS PER PLANS."},{"number":"EP-2022-007698","date":"2022-08-16","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-08-15","scope":"Install (1) 150 amp circuit breaker, 80 kw UPS system,(1) 100 amp circuit breaker & feeder, (1) 100 amp panel & feeder. Install wiring, conduits & basket tray for the new cyber knife procedure room. Install (31) Fixtures (1) Exit (7) switches (35) Receptacles, reinstall the existing smoke detectors and nurse call devices. Provide power for the (2) VAV's and (2) CRAC units."},{"number":"CP-2022-004208","date":"2022-09-06","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-05-30","scope":"FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN USE & OCCUPANCY CLASSIFICATION TO EXISTING GROUP B MEDICAL HEALTH PRACTITIONER OFFICES AT THE 2ND FLOOR. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC AND PHC APPROVAL DATED 7/26/2022. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. **ASBESTOS ABATEMENT REQUIRED**"},{"number":"CP-2022-004384","date":"2022-09-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"AMENDMENT II: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT CP-2022-004382 TO DOCUMENT DESIGN CHANGES TO FOUNDATION WORK. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. AMENDMENT I: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT CP-2022-004382 TO CHANGE CONFIGURATION OF CANOPY DUE TO LOCATION OF EXISTING UTILITIES. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ORIGINAL: FOR THE INSTALLATION OF AN EXTERIOR CANOPY ACCESSORY TO EXISTING HEALTH FACILITY, ALL WORK TO BE DONE PER APPROVED STRUCTURAL PLANS SEALED BY STRUCTURAL ENGINEER. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"OP-2022-000504","date":"2022-09-13","work":"Temporary Tents and Canopies","type":"Operations","description":"Operations Permit","status":"Expired","completedDate":"2023-09-27","scope":"INSTALLING MULTIPLE TENTS TO BE WEIGHTED ON ASPHALT FOR ARIA JEFFERSON HOSPITAL PICNIC AT 10800 KNIGHTS RD 19114. TENTS TO BE INSTALLED WEDNESDAY FOR THURSDAY USE AND REMOVAL THURSDAY EVENING."},{"number":"PP-2022-012016","date":"2022-09-13","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-09-26","scope":"Demo- Sinks-1 and 2- Remove sink faucet and associated piping. Cap Sanitary below the floor and cap hot, cold, and Vent at Branch Connections to Mains. Sink 3 remove sink faucet and associated piping cap sanitary above grade, cap hot water, cold water and vent piping above the ceiling for future. Extend 1 1/2\" sanitary from previous sink. Pipe in HW, CW, and vent per drawings. Rough in and connect 1/2\" oxygen and 3/4 med vac to med gas outlets. Install zone valve box above existing ZVB. Sink 2 Extend 2\" sanitary to existing sanitary from sink in mold room. Rough in HW,CW, and Vent per drawings. Run 1/2\" CW piping to crack units and humidifier."},{"number":"EP-2022-009035","date":"2022-09-17","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-05-12","scope":"INSTALL LIGHTS AND RECEPTACLES, NEW PANELS AND TRANSFORMER PER DRAWINGS AND 2017 NEC. FITOUT TO NEW FIRE ALARM SYSTEM TO EXISTING FIRE ALARM PANEL AS PER 2016 NFPA 72."},{"number":"MP-2022-004888","date":"2022-11-02","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-05-30","scope":"FOR ALTERATION TO THE EXISTING HVAC SYSTEM TO ACCOMMODATE NEW FLOOR LAYOUT AS PER APPROVED PLANS."},{"number":"FP-2022-003181","date":"2022-12-23","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-05-30","scope":"Relocate/modify/add to the existing fire sprinkler system to provide proper coverage to new office layout as per NFPA 13."},{"number":"PP-2022-017607","date":"2022-12-27","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-05-17","scope":"Renovation of existing medical space with the addition of new lav sinks, water closets and hand wash sinks. Installation of new water lines, sanitary and vent lines to connect to existing building plumbing."},{"number":"MP-2022-004317","date":"2023-01-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-09-26","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"CP-2023-000667","date":"2023-02-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN USE & OCCUPANCY CLASSIFICATION TO EXISTING GROUP B OFFICES. BUILDING IS NOT SPRINKLERED ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC AND PHC APPROVAL. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK."},{"number":"CP-2023-000548","date":"2023-02-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-09-11","scope":"FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, FURNISHINGS, MILLWORK, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS FOR MEP AND FIRE SUPPRESSION WORK."},{"number":"PP-2023-003360","date":"2023-03-14","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-09-11","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2023-003408","date":"2023-03-14","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-12-14","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2023-001137","date":"2023-03-15","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR LEVEL 2 ALTERATIONS TO EXISTING MORGUE AS PART OF AN EXISTING HOSPITAL AS PER PLANS."},{"number":"MP-2023-001190","date":"2023-03-29","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-09-11","scope":"FOR THE TIE IN TO EXISTING HVAC SYSTEMS, ASSOCIATED DUCT WORK, EXHAUST FAN, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION"},{"number":"CP-2023-001174","date":"2023-03-30","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-10-18","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING NUCLEAR MEDICINE ROOMS ON THE SECOND FLOOR OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"EP-2023-002595","date":"2023-04-12","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-07-19","scope":"INSTALL PANEL EE-AS1B 100 AMP PANEL & FEEDER, INSTALL LIGHTS NORMAL & EMERGENCY, SENSORS, SWITCHES & RECEPTACLES. PROVIDE POWER FOR THE COOLER BOX EQUIPMENT & EXHAUST FAN. ALL WORK IN ACCORDANCE WITH THE 2017 NEC."},{"number":"EP-2023-002605","date":"2023-04-19","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-12-07","scope":"35 Fixtures - 67 Receptacles - 15 T & D Boxes - 2 Floor Boxes - 100 - amp Panel - AHU - Exhaust Fan - Lighting Controls . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **SEPARATE FIRE ALARM PERMIT REQ'D**"},{"number":"EP-2023-003061","date":"2023-04-24","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-06-08","scope":"Install 13 Fixtures - 5 Switches - 9 Receptacles - Code blue Button - Raceways and Junction Boxes for Equipment . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. ** NO FIRE ALARM ON THIS PERMIT **"},{"number":"EP-2023-003298","date":"2023-04-24","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-02-20","scope":"Install new lighting in canopy as per APPROVED DRAWINGS-2017 nec"},{"number":"PP-2023-005560","date":"2023-05-01","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-10-03","scope":"INSTALL 2 SINKS ACCORDING TO THE 2018 PPC AND PER PLANS."},{"number":"EP-2023-002602","date":"2023-05-05","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-07-12","scope":"Install 8 Fixtures - 2 Floor Boxes - 62 Receptacles - 17 T & D Boxes - Card Reader & a VFD as per 2017 NEC."},{"number":"EP-2023-003062","date":"2023-05-05","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-10-03","scope":"Install 9 Fixtures - 2 Switches - 6 Receptacles - code Blue Button - Install Raceways and Junction Boxes as needed for Equipment as per 2017 NEC."},{"number":"CP-2023-001796","date":"2023-05-16","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR LEVEL II INTERIOR ALTERATIONS WITH NO CHANGE IN OCCUPANCY PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION."},{"number":"MP-2023-001201","date":"2023-05-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-12-14","scope":"FOR THE PARTIAL DEMO AND INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2023-001156","date":"2023-05-24","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Issued","completedDate":null,"scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (12) sprinkler heads to accommodate interior alterations on first floor."},{"number":"MP-2023-001868","date":"2023-05-26","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-10-03","scope":"FOR THE PARTIAL DEMO AND THE INSTALLATION OF REGISTERS, AND DIFFUSERS, WITH ASSOCIATED DUCTWORK. TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"PP-2023-007622","date":"2023-06-05","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-08-30","scope":"Replacement of fixture: remove existing clinical sink and replace with hand sink in morgue. WITHOUT PIPING"},{"number":"MP-2023-002283","date":"2023-06-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Issued","completedDate":null,"scope":"FOR THE INSTALLATION OF HVAC EQUIPMENT, APPLICANCES, DUCTWORK AND REGISTERS/DIFFUSER PER APPROVD PLANS AND MANUFACTURER'S SPECIFICATIONS."},{"number":"FP-2023-000949","date":"2023-06-12","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-09-26","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate/modify 28 existing fire sprinklers to provide proper coverage due to construction changes"},{"number":"MP-2023-001877","date":"2023-06-24","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Issued","completedDate":null,"scope":"FOR THE REMOVAL AND REPLACEMENT OF A PORTION OF THE EXISTING HVAC SYSTEM IN RECONFIGURED MORGUE AS PER APPLICATION/PLANS AND IN ACCORDANCE WITH THE 2018 IMC. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2023-001147","date":"2023-07-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Issued","completedDate":null,"scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 5 SPRINKLER HEADS IN MORGUE RENOVATION"},{"number":"CP-2023-004391","date":"2023-09-13","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-09-20","scope":"FOR LEVEL 2 ALTERATIONS TO AN EXISTING HOSPITAL AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK."},{"number":"EP-2023-004916","date":"2023-09-14","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-09-15","scope":"INSTALLING RECEPTACLES, LIGHTING ACCORDING TO THE 2017 NEC AND PER PLANS. **********************SEPARATE FIRE ALARM PERMIT IS REQUIRED********************************"},{"number":"FP-2023-001348","date":"2023-09-19","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-10-18","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 12 existing sprinkler heads to accommodate new wall layout - Nuclear med area. NO EXTERIOR WORK PROPOSED ON THIS. PHC APPROVED ON BUILDING PERMIT."},{"number":"EP-2023-007177","date":"2023-09-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-03-07","scope":"INSTALL FIRE ALARM DEVICES AS PER DRAWINGS AND 2016 NFPA 72."},{"number":"EP-2023-010639","date":"2023-11-12","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-12-08","scope":"Install 9 Smokes - 5 Strobes - 4 Horn / Strobes & 1 Pull Station . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72."},{"number":"EP-2023-011623","date":"2024-01-01","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-08-16","scope":"Install 279 Light Fixtures, 107 Receptacles, Nurse Call Devices for Procedure and Staff Rooms, 3 AHUs, 1 CU unit, 2 Exhaust Fans, Install Panels D2, G2, and EPC2 as per 2017 NEC. ***NOT APPROVED FOR INSTALLATION OF FIRE ALARM."},{"number":"CP-2023-006649","date":"2024-01-04","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-05-31","scope":"FOR LEVEL II INTERIOR ALTERATIONS ON THE SECOND-FLOOR OF AN EXISTING BUILDING. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION."},{"number":"CP-2023-006981","date":"2024-01-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-03-27","scope":"FOR LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) IN EXISTING BUILDING PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION."},{"number":"MP-2024-000058","date":"2024-01-22","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-05-30","scope":"For installation of HVAC system to accommodate new office layout as per approved plans."},{"number":"CP-2024-000057","date":"2024-01-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-07-03","scope":"FOR LEVEL II ALTERATIONS ON THE THIRD FLOOR OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS AND PA DOH APPROVAL. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2024-000222","date":"2024-02-08","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-05-31","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (12) sprinkler heads to accommodate alterations on 2nd floor"},{"number":"MP-2024-000157","date":"2024-02-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-09-20","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW LAYOUT ON THE SECOND FLOOR OF AN EXISTING HOSPITAL AS PER APPROVED PLANS. *2018 IMC REVIEW*"},{"number":"PP-2024-002884","date":"2024-02-29","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-07-03","scope":"REPLACEMENT OF A FLOOR DRAIN WITH A FLOOR SINK AS PER APPROVED DRAWINGS"},{"number":"FP-2024-000293","date":"2024-03-01","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-09-20","scope":"FOR ALTERATIONS TO EXISTING FIRE SUPPRESSION SYSTEM FOR THE RELOCATION OF SPRINKLER HEADS FOR NEW LAYOUT AS PER PLANS. NFPA 13"},{"number":"EP-2024-001915","date":"2024-03-05","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-12-23","scope":"INSTALL A NEW FIRE ALARM SYSTEM WITH EMERGENCY VOICE ALARM EVACUATION SYSTEM THROUGHOUT THE HOSPITAL CAMPUS. ALL WORK IN ACCOREANCE WITH THE 2017 NEC."},{"number":"MP-2024-000961","date":"2024-03-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-07-03","scope":"FOR ALTERATIONS TO THE EXISTING HVAC SYSTEM TO REPLACE ONE CEILING DIFFUSERS AND ASSOCIATED DUCTWORK AS PER PLANS."},{"number":"EP-2024-001524","date":"2024-03-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-06-12","scope":"Install 16 Fixtures, 18 Receptacles, 60amp Isolation Panel and 70-amp Panel, Lighting Controls, 50-amp Receptacle..ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**"},{"number":"EP-2024-002431","date":"2024-04-09","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-05-28","scope":"Rough-In Permit for EP-2024-002429 Install 27 Fixtures - 12 Switches - 52 Receptacles"},{"number":"PP-2024-001412","date":"2024-04-15","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-09-20","scope":"Plumbing per plans"},{"number":"FP-2024-000766","date":"2024-04-18","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-07-03","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 5 EXISITNG SPRINKLER HEADS TO ACCOMODATE NEW ARCHITECTURAL LAYOUT"},{"number":"EP-2024-002429","date":"2024-04-22","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-05-28","scope":"INSTALL NEW LIGHT FIXTURES NORMAL & EMERGENCY, SWITCHES, SENSORS & DIMMERS CONNECTING TO THE EXISTING LIGHT CIRCUITS. INSTALL RECEPTACLES USING EXISTING CIRCUITS & ADDITIONAL NEW CIRCUITS & 20 AMP 1 POLE CIRCUIT BREAKERS AS NEEDED. ALL WORK IN ACCORDANCE WITH THE 2017 NEC."},{"number":"CP-2024-001959","date":"2024-04-29","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-02-11","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING HOSPITAL (I-2 (CONDITION-2) OCCUPANCY), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ***ASBESTOS REMEDIATION REQUIRED ***"},{"number":"MP-2024-001980","date":"2024-05-15","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-03-27","scope":"FOR ALTERATIONS TO HVAC SYSTEM INCLUDING NEW REGISTERS AND DIFFUSERS WITH ASSOCIATED DUCTWORK AS PER PLANS."},{"number":"PP-2024-006101","date":"2024-06-14","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2026-03-27","scope":"ALTERATIONS TO PLUMBING AS PER APPROVED DRAWINGS TO INCLUDE FIXTURES AS INDICATED AND (2) SURGICAL SCRUB SINKS"},{"number":"FP-2024-001330","date":"2024-06-25","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-03-27","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (61) sprinkler heads to accommodate interior alterations for IR renovation"},{"number":"EP-2024-003788","date":"2024-06-26","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-03-23","scope":"Install 158 Receptacles, 340 Quad Outlets, New Lighting and Controls, MDP Panel, 2 Dual Panel Isolation Panels, 2 Shunt Trip Circuit Breakers, Reinstall Existing FA Devices, Raceways and Security Work . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC."},{"number":"MP-2024-003499","date":"2024-08-06","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-02-07","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND DUCT WORK TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2024-007522","date":"2024-08-26","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-12-09","scope":"Install 45 New light Fixtures, 15 Switches and 55 Receptacles according to the 2017 NEC and per plans. Reusing existing circuits."},{"number":"PP-2024-013224","date":"2024-10-30","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-02-11","scope":"Rough in drain water and vent for (7)- Exam Rm Sinks INSTALLED PER 2018 PPC AND APPROVED PLANS"},{"number":"FP-2024-002034","date":"2024-11-01","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-03-27","scope":"FOR THE INSTALLATION OF PRE-ACTION SPRINKLER SYSTEM OF 13 SPRINKLER HEADS ON PARTIAL SECOND FLOOR TIED TO THE EXISTING FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 AND AN EXISTING BACKFLOW PREVENTION ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"CP-2025-001122","date":"2025-03-26","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-09-22","scope":"FOR PARTIAL DEMO AND LEVEL II ALTERATIONS AT 2ND FLOOR CATH LAB AND CONTROL ROOM TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. ***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************"},{"number":"FP-2025-000665","date":"2025-04-01","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-09-22","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (4) sprinklers to accommodate 2nd floor cath lab alterations"},{"number":"PP-2025-004378","date":"2025-04-10","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Issued","completedDate":null,"scope":"INSTALLATION OF NEW SCRUB SINK AND ASSOCIATED PIPING CONNECTING TO FUTURE CONNECTIONS. ALL WORK PERFORMED IN COMPLIANCE WITH 2018 PPC"},{"number":"EP-2025-002993","date":"2025-04-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-08-11","scope":"Install 26 Fixtures - 3 Dimmers - 29 Receptacles - 1 ACC - 1 Crac Unit - Raceways Dedicated Outlet - 2 Shut Trip Buttons - Nurse Call Pull and Dome .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**"},{"number":"CP-2025-001496","date":"2025-05-01","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR THE ERECTION OF STRUCTURE TO HOUSE NEW COOLING TOWER AND LEVEL II ALTERATIONS TO INCLUDE NEW EXTERIOR WALL OPENINGS, CONCRETE PAD AND INSTALLATION OF LINTELS. SEPARATE PERMITS REQUIRED FOR MEP WORK. *NO EXCAVATION WORK GREATER THAN 5FT, OTHERWISE SEPARATE PERMIT REQUIRED.* AMENDMENT TO INCLUDE STRUCTURAL WORK MODIFIED FOUNDATIONS."},{"number":"CP-2025-002683","date":"2025-05-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-03-27","scope":"FOR LEVEL II INTERIOR ALTERATIONS TO AN EXISTING NUCLEAR MEDICINE ROOM AS PART OF AN EXISTING GROUP I-2 HOSPITAL. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC, PHC APPROVAL, AND PA DOH APPROVAL. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK."},{"number":"EP-2025-003465","date":"2025-06-10","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-08-13","scope":"Install (2) smoke detectors, (1) strobe, and (1) speaker/strobe. Relocate (1) smoke detector as per 2016 NFPA 72."},{"number":"MP-2025-001964","date":"2025-06-16","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-09-22","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2025-004438","date":"2025-07-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"Install (52) lighting fixtures, (4) electrical devices, (15) mechanical equipment connections, (1) double ended sub station, (11) electrical panels and (4) transformers. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. -NOTED :DOOR SWINGS WERE CORRECTED AND PANIC HARDWARE ADDED(SEE CLOUDED AREAS)"},{"number":"MP-2025-004465","date":"2025-10-01","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-03-27","scope":"FOR THE INSTALLATION OF REGISTERS / DIFFUSERS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2025-011684","date":"2025-12-24","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-03-23","scope":"Install 6 2x2's - 8 High Hats - 1 Under counter light - 4 switches - 8 Receptacles - 150-amp Circuit Breaker . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC."},{"number":"PP-2025-016752","date":"2026-01-05","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2026-03-27","scope":"Install 1- sink (other) ; medical gas lines(other) and piping as per plans ALL WORK PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND PLUMBING EZ STANDARD."},{"number":"OP-2026-000144","date":"2026-05-12","work":"Temporary Tents and Canopies","type":"Operations","description":"Operations Permit","status":"Expired","completedDate":"2026-05-22","scope":"ASSEMBLY USE TENT - LAWFUL OCCUPANCY SHALL BE AS POSTED - REMOVAL DATE ELECTRICAL PERMIT REQUIRED, UNLESS POWER IS PROVIDED THROUGH EXISTING EXTERIOR GROUND FAULT PROTECTED RECEPTACLES AND POWER CORDS ARE RATED EXTRA HEAVY DUTY WITH U. L. LABEL STATING SUCH RATING. NO COOKING OR HEATING PERMITTED WITH THIS APPROVAL. Streets Department permit is required for street closure prior to the start work if applicable."}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Alterations"},{"y":2026,"k":"permit","w":"Temporary Tents and Canopies"}],"rented":false,"licenses":[{"number":"206164","type":"Food Preparing and Serving","status":"Inactive","businessName":"JAVA JOE'S","legalName":"JAVA JOE'S","address":"10800 KNIGHTS RD","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2003-04-20","latestIssueDate":"2003-04-20","expirationDate":"2004-04-30","inactiveDate":null},{"number":"208886","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"FRANKFORD HOSPITAL T C","legalName":"FRANKFORD HOSPITAL T C","address":"10800 KNIGHTS RD","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2004-04-19","latestIssueDate":"2009-10-21","expirationDate":"2010-04-30","inactiveDate":"2012-12-22"},{"number":"208607","type":"Food Preparing and Serving","status":"Inactive","businessName":"JAVA JOE'S INC","legalName":"JAVA JOE'S INC","address":"10800 KNIGHTS RD","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2004-04-30","latestIssueDate":"2016-04-28","expirationDate":"2017-04-30","inactiveDate":"2017-06-29"},{"number":"442013","type":"Hazardous Materials","status":"Inactive","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","address":"10800 KNIGHTS RD","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2010-01-14","latestIssueDate":"2014-07-10","expirationDate":"2014-12-31","inactiveDate":"2015-03-01"},{"number":"512104","type":"Food Preparing and Serving (30+ SEATS)","status":"Active","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","address":"10800 KNIGHTS RD","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2010-08-19","latestIssueDate":"2026-04-09","expirationDate":"2027-04-30","inactiveDate":null},{"number":"513961","type":"Food Establishment, Retail Permanent Location","status":"Active","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","address":"10800 KNIGHTS RD","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2010-09-08","latestIssueDate":"2026-04-09","expirationDate":"2027-04-30","inactiveDate":null},{"number":"518202","type":"Dumpster License - Private Property","status":"Active","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","address":"10800 KNIGHTS RD","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2010-10-28","latestIssueDate":"2013-09-24","expirationDate":null,"inactiveDate":null},{"number":"744284","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"Lori's Gifts, Inc.","legalName":"Lori's Gifts, Inc.","address":"10800 KNIGHTS RD","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2017-07-03","latestIssueDate":"2022-09-26","expirationDate":"2023-07-02","inactiveDate":"2023-08-31"}],"licenseActivity":[{"number":"744284","type":"Food Establishment, Retail Permanent Location","businessName":"Lori's Gifts, Inc.","legalName":"Lori's Gifts, Inc.","issuedDate":"2017-07-03","latestIssueDate":"2022-09-26","closureDate":"2023-08-31","expirationDate":"2023-07-02","inactiveDate":"2023-08-31","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"518202","type":"Dumpster License - Private Property","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","issuedDate":"2010-10-28","latestIssueDate":"2013-09-24","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"513961","type":"Food Establishment, Retail Permanent Location","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","issuedDate":"2010-09-08","latestIssueDate":"2026-04-09","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"512104","type":"Food Preparing and Serving (30+ SEATS)","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","issuedDate":"2010-08-19","latestIssueDate":"2026-04-09","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"442013","type":"Hazardous Materials","businessName":"ARIA HEALTH (ARIA HEALTH TORRESDALE CAMPUS)","legalName":"ARIA HEALTH","issuedDate":"2010-01-14","latestIssueDate":"2014-07-10","closureDate":"2015-03-01","expirationDate":"2014-12-31","inactiveDate":"2015-03-01","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"208607","type":"Food Preparing and Serving","businessName":"JAVA JOE'S INC","legalName":"JAVA JOE'S INC","issuedDate":"2004-04-30","latestIssueDate":"2016-04-28","closureDate":"2017-06-29","expirationDate":"2017-04-30","inactiveDate":"2017-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"208886","type":"Food Preparing and Serving (30+ SEATS)","businessName":"FRANKFORD HOSPITAL T C","legalName":"FRANKFORD HOSPITAL T C","issuedDate":"2004-04-19","latestIssueDate":"2009-10-21","closureDate":"2012-12-22","expirationDate":"2010-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"206164","type":"Food Preparing and Serving","businessName":"JAVA JOE'S","legalName":"JAVA JOE'S","issuedDate":"2003-04-20","latestIssueDate":"2003-04-20","closureDate":"2004-04-30","expirationDate":"2004-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-23","signals":[{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["12 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #117138: COMPLETED. The history also contains “PERMP- FINAL PRE-CO INSP.”","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"22 permits not marked completed: 274060 (Expired), 361024 (EXPIRED), 388490 (Expired), 640093 (Expired), 646322 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"attention","title":"A life-safety certification appears expired","finding":"Special Hazards Certification: Certified through Mar 4, 2027; Fire Alarm Certification: Certified through Aug 1, 2025","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"18 failed, 13 passed, and 2 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Mar 6, 2020.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Preparing and Serving #206164: Inactive; Food Preparing and Serving (30+ SEATS) #208886: Inactive since Dec 22, 2012; Food Preparing and Serving #208607: Inactive since Jun 29, 2017; Hazardous Materials #442013: Inactive since Mar 1, 2015","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"full-tax-exemption","level":"verify","title":"OPA shows a full exemption; its legal basis is unverified","finding":"OPA currently marks the land and building assessment fully tax-exempt; BlockReport does not receive the exemption determination or basis.","why":"Full OPA exemptions can have different legal bases, including government, religious, charitable/institutional, veteran, or other treatment. The current owner/use record is not a buyer’s tax forecast.","action":"Confirm the exact exemption basis, buyer eligibility, and next tax-year treatment directly with OPA.","url":"https://www.phila.gov/departments/office-of-property-assessment/tax-exemptions-and-abatements/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as commercial. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 21 historical violations across 11 cases.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}