{"asOf":"2026-07-26T06:18:11.848Z","block":"200-299 N 21ST ST","blockUrl":"https://philadelphia.blockreport.homes/block/200-299-n-21st-st","address":"201 N 21ST ST","parcelNumber":"782779400","source":"https://property.phila.gov/?p=782779400","ownerType":"investor","kind":"commercial","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"ZD0","buildingCodeNew":"680","buildingClass":"MISC MUSEUM MASONRY","buildingClassNew":"CULTURAL FACILITIES","useLabel":"Museum","owner":"CITY OF PHILA","coOwner":"FRANKLIN INSTITUTE","marketValue":87965400,"landAssessment":11669500,"improvementAssessment":76295900,"livableArea":221300,"yearBuilt":1932,"lastSale":{"price":1,"date":"2016-03-30T04:00:00Z"},"openViolations":16,"violations":[{"number":"1734574","date":"2007-03-28","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"2045895","date":"2010-06-11","code":"FC-404.4/1","title":"FIRE/EVAC PLN-UPDATE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2045898","date":"2010-06-11","code":"FC-408.2/1","title":"FIRE/EVAC PLN-GROUP A-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2045897","date":"2010-06-11","code":"FC-406.1/1","title":"FIRE/EVAC PLN-EMPLY TRNG DUTY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2045896","date":"2010-06-11","code":"FC-404.4/2","title":"FIRE/EVAC PLN-PFD APPROV UPDAT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2578300","date":"2012-09-12","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2578301","date":"2012-09-12","code":"FC-1004.3/1","title":"EGRESS-ASSEM OCC SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2848153","date":"2013-07-01","code":"E-1201.1/104","title":"TAPS/SPLICES-DISSIMILAR METALS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2848154","date":"2013-07-01","code":"E-1201.1/106","title":"EQUIP NOT PER LABEL & LISTING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2848155","date":"2013-07-01","code":"E-1201.1/108","title":"OPENING-REQ'D TO CLOSE UNUSED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2955981","date":"2013-10-02","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2955982","date":"2013-10-02","code":"E-102.1/1","title":"CONTR (ELEC) LIC REQ'D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2956013","date":"2013-10-02","code":"E-102.1/1","title":"CONTR (ELEC) LIC REQ'D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2956012","date":"2013-10-02","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2022-019584","date":"2022-03-22","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-019586","date":"2022-03-22","code":"F-907.8.5","title":"INSPECTION, TESTING AND MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2022-019585","date":"2022-03-22","code":"F-1004.9","title":"POSTING OF OCCUPANT LOAD\n","status":"CLOSED","resolutionDate":"2025-03-10","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2022-019583","date":"2022-03-22","code":"F-1013.6.2","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-019582","date":"2022-03-22","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2025-012490","date":"2025-03-10","code":"F-904.5.1","title":"WET CHEMICAL SYSTEM TEST\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012412","date":"2025-03-10","code":"F-1104.30","title":"OCCUPANT LOAD SIGN\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012379","date":"2025-03-10","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012380","date":"2025-03-10","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012381","date":"2025-03-10","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012385","date":"2025-03-10","code":"F-1008.3","title":"EMERGENCY POWER FOR ILLUMINATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012389","date":"2025-03-10","code":"F-105.6.1.8","title":"HAZARDOUS MATERIALS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012396","date":"2025-03-10","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012397","date":"2025-03-10","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012399","date":"2025-03-10","code":"F-604.6","title":"UNAPPROVED CONDITIONS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012410","date":"2025-03-10","code":"F-5303.5.3","title":"SECURING COMPRESSED CYLINDERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012411","date":"2025-03-10","code":"F-1104.28","title":"EXIT DOORS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012477","date":"2025-03-10","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012486","date":"2025-03-10","code":"F-703.1","title":"PENETRATIONS MAINTAINING PROTECTION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-094605","date":"2025-12-04","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-094606","date":"2025-12-04","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"2961742","date":"2013-10-02","code":"9-1004","title":"CVN-UNLIC GENERAL CONTR","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"107137","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-03-29","completedDate":"2010-06-30","violations":[{"number":"1734574","date":"2007-03-28","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"239071","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2010-06-11","completedDate":"2011-06-14","violations":[{"number":"2045895","date":"2010-06-11","code":"FC-404.4/1","title":"FIRE/EVAC PLN-UPDATE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2045898","date":"2010-06-11","code":"FC-408.2/1","title":"FIRE/EVAC PLN-GROUP A-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2045897","date":"2010-06-11","code":"FC-406.1/1","title":"FIRE/EVAC PLN-EMPLY TRNG DUTY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2045896","date":"2010-06-11","code":"FC-404.4/2","title":"FIRE/EVAC PLN-PFD APPROV UPDAT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"350604","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-09-17","completedDate":"2013-02-07","violations":[{"number":"2578300","date":"2012-09-12","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2578301","date":"2012-09-12","code":"FC-1004.3/1","title":"EGRESS-ASSEM OCC SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"389261","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2013-07-02","completedDate":"2013-07-05","violations":[{"number":"2848153","date":"2013-07-01","code":"E-1201.1/104","title":"TAPS/SPLICES-DISSIMILAR METALS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2848154","date":"2013-07-01","code":"E-1201.1/106","title":"EQUIP NOT PER LABEL & LISTING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2848155","date":"2013-07-01","code":"E-1201.1/108","title":"OPENING-REQ'D TO CLOSE UNUSED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"405107","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2013-10-02","completedDate":"2013-12-17","violations":[{"number":"2955981","date":"2013-10-02","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2955982","date":"2013-10-02","code":"E-102.1/1","title":"CONTR (ELEC) LIC REQ'D","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"405115","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2013-10-02","completedDate":"2013-12-17","violations":[{"number":"2956013","date":"2013-10-02","code":"E-102.1/1","title":"CONTR (ELEC) LIC REQ'D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2956012","date":"2013-10-02","code":"A-901.13/2","title":"PENALTY- NO ELEC PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2022-023877","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2022-03-23","completedDate":"2025-03-11","violations":[{"number":"VI-2022-019584","date":"2022-03-22","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-019586","date":"2022-03-22","code":"F-907.8.5","title":"INSPECTION, TESTING AND MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2022-019585","date":"2022-03-22","code":"F-1004.9","title":"POSTING OF OCCUPANT LOAD\n","status":"CLOSED","resolutionDate":"2025-03-10","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2022-019583","date":"2022-03-22","code":"F-1013.6.2","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-019582","date":"2022-03-22","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-03-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2025-015857","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PUBLIC PROPERTY","status":"IN VIOLATION","createdDate":"2025-03-10","completedDate":null,"violations":[{"number":"VI-2025-012490","date":"2025-03-10","code":"F-904.5.1","title":"WET CHEMICAL SYSTEM TEST\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012412","date":"2025-03-10","code":"F-1104.30","title":"OCCUPANT LOAD SIGN\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012379","date":"2025-03-10","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012380","date":"2025-03-10","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012381","date":"2025-03-10","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012385","date":"2025-03-10","code":"F-1008.3","title":"EMERGENCY POWER FOR ILLUMINATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012389","date":"2025-03-10","code":"F-105.6.1.8","title":"HAZARDOUS MATERIALS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012396","date":"2025-03-10","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012397","date":"2025-03-10","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012399","date":"2025-03-10","code":"F-604.6","title":"UNAPPROVED CONDITIONS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012410","date":"2025-03-10","code":"F-5303.5.3","title":"SECURING COMPRESSED CYLINDERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012411","date":"2025-03-10","code":"F-1104.28","title":"EXIT DOORS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012477","date":"2025-03-10","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-012486","date":"2025-03-10","code":"F-703.1","title":"PENETRATIONS MAINTAINING PROTECTION\n","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"CF-2025-130641","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL PUBLIC PROPERTY","status":"IN VIOLATION","createdDate":"2025-12-04","completedDate":null,"violations":[{"number":"VI-2025-094605","date":"2025-12-04","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-094606","date":"2025-12-04","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"381570","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"2961742","date":"2013-10-02","code":"9-1004","title":"CVN-UNLIC GENERAL CONTR","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2007,"n":1,"worst":null},{"y":2010,"n":4,"worst":null},{"y":2012,"n":2,"worst":null},{"y":2013,"n":8,"worst":null},{"y":2022,"n":5,"worst":null},{"y":2025,"n":16,"worst":null}],"investigations":[{"caseNumber":"59773","date":"2006-03-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"107137","date":"2007-03-28","type":"BC INSP","status":"FAILED"},{"caseNumber":"59773","date":"2007-05-14","type":"CI INSP","status":"FAILED"},{"caseNumber":"59773","date":"2007-06-14","type":"CI INSP","status":"FAILED"},{"caseNumber":"59773","date":"2010-01-06","type":"CI INSP","status":"FAILED"},{"caseNumber":"59773","date":"2010-02-23","type":"CI INSP","status":"PASSED"},{"caseNumber":"107137","date":"2010-06-29","type":"BC INSP","status":"PASSED"},{"caseNumber":"239071","date":"2010-07-29","type":"CI INSP","status":"FAILED"},{"caseNumber":"239071","date":"2010-09-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"239071","date":"2010-10-28","type":"CI INSP","status":"FAILED"},{"caseNumber":"239071","date":"2011-02-08","type":"CI INSP","status":"FAILED"},{"caseNumber":"239071","date":"2011-04-20","type":"CI INSP","status":"PASSED"},{"caseNumber":"239071","date":"2011-06-14","type":"CI INSP","status":"PASSED"},{"caseNumber":"350604","date":"2012-09-12","type":"CI INSP","status":"FAILED"},{"caseNumber":"350604","date":"2013-02-06","type":"CI INSP","status":"PASSED"},{"caseNumber":"389261","date":"2013-07-01","type":"EP_ELEC","status":"FAILED"},{"caseNumber":"389261","date":"2013-07-05","type":"EP_ELEC","status":"PASSED"},{"caseNumber":"405115","date":"2013-10-02","type":"EP_ELEC","status":"FAILED"},{"caseNumber":"405107","date":"2013-10-02","type":"EP_ELEC","status":"FAILED"},{"caseNumber":"405107","date":"2013-12-17","type":"EP_ELEC","status":"PASSED"},{"caseNumber":"405115","date":"2013-12-17","type":"EP_ELEC","status":"PASSED"},{"caseNumber":"CF-2022-023877","date":"2022-03-23","type":null,"status":"FAILED"},{"caseNumber":"CF-2022-023877","date":"2025-03-11","type":null,"status":"PASSED"},{"caseNumber":"CF-2025-015857","date":"2025-03-11","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-130641","date":"2025-12-04","type":null,"status":"FAILED"}],"inspYears":[{"y":2006,"fails":1,"passes":0},{"y":2007,"fails":3,"passes":0},{"y":2010,"fails":4,"passes":2},{"y":2011,"fails":1,"passes":2},{"y":2012,"fails":1,"passes":0},{"y":2013,"fails":3,"passes":4},{"y":2022,"fails":1,"passes":0},{"y":2025,"fails":2,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.95819919307055,"lng":-75.17318690237774,"geom":{"type":"Polygon","coordinates":[[[-75.172531909,39.957522194],[-75.174098191,39.95772073],[-75.173841909,39.958876188],[-75.1722756,39.958677649],[-75.172531909,39.957522194]]]},"liDistrict":"CENTRAL WEST","certifications":[{"number":"BC-2022-010025","type":"Facade Report","inspectionDate":"2008-06-18","result":"Safe","expirationDate":"2013-06-18","buildingId":"1378457"},{"number":"BC-2022-003087","type":"Facade Report","inspectionDate":"2017-05-01","result":"Safe with Repair","expirationDate":"2022-05-01","buildingId":"1378457"},{"number":"BC-2022-007513","type":"Special Hazards Certification","inspectionDate":"2022-05-26","result":"Certified","expirationDate":"2023-05-26","buildingId":"1378457"},{"number":"BC-2022-015772","type":"Special Hazards Certification","inspectionDate":"2022-10-26","result":"Certified","expirationDate":"2023-10-26","buildingId":"1378457"},{"number":"BC-2023-012658","type":"Special Hazards Certification","inspectionDate":"2023-06-13","result":"Certified","expirationDate":"2024-06-13","buildingId":"1378457"},{"number":"BC-2024-008146","type":"Sprinkler Certification","inspectionDate":"2023-09-27","result":"Deficient","expirationDate":null,"buildingId":"1378457"},{"number":"BC-2024-007844","type":"Special Hazards Certification","inspectionDate":"2023-10-20","result":"Certified","expirationDate":"2024-04-30","buildingId":"1378457"},{"number":"BC-2024-014432","type":"Special Hazards Certification","inspectionDate":"2024-05-06","result":"Deficient","expirationDate":null,"buildingId":"1378457"},{"number":"BC-2024-014430","type":"Special Hazards Certification","inspectionDate":"2024-05-06","result":"Certified","expirationDate":"2024-11-30","buildingId":"1378457"},{"number":"BC-2024-027405","type":"Sprinkler Certification","inspectionDate":"2024-08-26","result":"Deficient","expirationDate":null,"buildingId":"1378457"},{"number":"BC-2025-028076","type":"Sprinkler Certification","inspectionDate":"2024-08-26","result":"Certified","expirationDate":"2025-08-26","buildingId":"1378457"},{"number":"BC-2025-000730","type":"Special Hazards Certification","inspectionDate":"2024-12-16","result":"Certified","expirationDate":"2025-12-16","buildingId":"1378457"},{"number":"BC-2025-007114","type":"Special Hazards Certification","inspectionDate":"2025-03-11","result":"Deficient","expirationDate":null,"buildingId":"1378457"},{"number":"BC-2025-013955","type":"Special Hazards Certification","inspectionDate":"2025-05-22","result":"Certified","expirationDate":"2026-05-22","buildingId":"1378457"},{"number":"BC-2025-026753","type":"Sprinkler Certification","inspectionDate":"2025-08-29","result":"Deficient","expirationDate":null,"buildingId":"1378457"},{"number":"BC-2025-025480","type":"Facade Report","inspectionDate":"2025-09-24","result":"Safe with Repair","expirationDate":"2030-09-24","buildingId":"1378457"},{"number":"BC-2025-025430","type":"Special Hazards Certification","inspectionDate":"2025-09-25","result":"Deficient","expirationDate":null,"buildingId":"1378457"},{"number":"BC-2025-028880","type":"Special Hazards Certification","inspectionDate":"2025-10-31","result":"Certified","expirationDate":"2026-10-31","buildingId":"1378457"},{"number":"BC-2026-002515","type":"Fire Alarm Certification","inspectionDate":"2026-01-20","result":"Certified","expirationDate":"2027-01-20","buildingId":"1378457"},{"number":"BC-2026-007912","type":"Special Hazards Certification","inspectionDate":"2026-03-19","result":"Certified","expirationDate":"2027-03-19","buildingId":"1378457"},{"number":"BC-2026-012537","type":"Special Hazards Certification","inspectionDate":"2026-04-22","result":"Certified","expirationDate":"2027-04-22","buildingId":"1378457"},{"number":"BC-2026-012542","type":"Special Hazards Certification","inspectionDate":"2026-04-22","result":"Certified","expirationDate":"2027-04-22","buildingId":"1378457"},{"number":"BC-2026-017096","type":"Emergency and Standby Power Systems Certification","inspectionDate":"2026-05-11","result":"Certified","expirationDate":"2027-05-11","buildingId":"1378457"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19103","beds":null,"baths":null,"stories":null,"lotArea":190015,"zoning":"RM3","grade":"A+","basement":null,"heater":null,"centralAir":null,"extCond":"3","intCond":"3","garage":null,"homestead":false,"mail":"201 N 21ST ST, PHILADELPHIA PA, 19103","mailOut":false,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT/ CERTIFICATE FOR THE PARTIAL DEMOLITION OF THE STRUCTURE, FOR THE ERECTION OF A FOUR (4) STORY ADDITION MAX HEIGHT 84 FT AS PART OF AN EXISTING MUSEUM, FOR REMOVAL OF TWO (2) LOADING SPACES AND FOR ONE (1) ACC LOADING SPACE, FOR THE ","status":"CLOSED","outcome":"Granted with conditions","date":"2010-10-20","number":"12171","relatedPermit":"283271"},{"type":"Zoning board appeal","grounds":"PERMIT FOR A FACE AND FORMAT CHANGE TO AN EXISTING DOUBLE-FACED FREE-STANDING SIGN BY INSTALLATION OF TWO (2) DIGITAL DISPLAY SIGN FACES (FLASHING AND INTERMITTENT ILLUMINATION) ON THE EXISTING SIGN STRUCTURE AS PART OF AN EXISTING MUSEUM W","status":"CLOSED","outcome":"Granted","date":"2013-04-24","number":"18747","relatedPermit":"416761"},{"type":"LIRB-C Other L&I","grounds":"appellant..\"disagree with violation and/or action\" as reason to appeal\n\njb","status":"Closed","outcome":"Complete","date":"2026-07-17","number":"HA-2026-001084","relatedPermit":null}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":true,"assessmentExemption":true,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":82263000,"taxable":0,"land":38003000,"improvement":44260000,"taxableLand":0,"taxableImprovement":0,"exemptLand":38003000,"exemptImprovement":44260000},{"y":2017,"v":82263000,"taxable":0,"land":38003000,"improvement":44260000,"taxableLand":0,"taxableImprovement":0,"exemptLand":38003000,"exemptImprovement":44260000},{"y":2018,"v":87965400,"taxable":269000,"land":11669532,"improvement":76295868,"taxableLand":269000,"taxableImprovement":0,"exemptLand":11400532,"exemptImprovement":76295868},{"y":2019,"v":87965400,"taxable":269000,"land":11669500,"improvement":76295900,"taxableLand":269000,"taxableImprovement":0,"exemptLand":11400500,"exemptImprovement":76295900},{"y":2020,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900},{"y":2021,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900},{"y":2022,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900},{"y":2023,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900},{"y":2024,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900},{"y":2025,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900},{"y":2026,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900},{"y":2027,"v":87965400,"taxable":531798,"land":11669500,"improvement":76295900,"taxableLand":531798,"taxableImprovement":0,"exemptLand":11137702,"exemptImprovement":76295900}],"taxNow":7444,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"53541","date":"2007-01-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-02-02","scope":"MUSEUM-MAIN LEVEL-RELOCATE FIRE SPINKLER HEADS (3) TO MEET NEW WALL & CEILING LAYOUT"},{"number":"107435","date":"2007-10-05","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-10-26","scope":"INTERIOR DEMOLITION OF NON BEARING PARTITIONS"},{"number":"1672","date":"2007-12-21","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2007-12-21","scope":"12/22/07 - STANDING MARQUEE ERECTED @ ENTRANCE TO FRANKLIN INSTITUTE"},{"number":"124570","date":"2008-01-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-06-27","scope":"TWO PANEL BOARDS, BRANCH CIRCUITRY, NEW LIGHTING (CC DIST)"},{"number":"151331","date":"2008-05-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-03-06","scope":"INTERIOR ALTERATIONS TO THE SECOND, FOURTH AND ROOF LEVELS OF THE FRANKLIN HALL AS PER PLANS."},{"number":"154929","date":"2008-06-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-03-18","scope":"REPOINTING EXTERIOR AS NEEDED;REPLACE SKYLIGHT PER PLANS. CONTRACTOR MUST CONTACT HISTORICAL COMMISSION TO OBTAIN FIELD INSPECTION AND APPROVAL OF MASONRY SAMPLES UPON THE START OF WORK."},{"number":"162210","date":"2008-07-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLATION OF A STATE OF THE ART THEATRICAL LIGHTING SYSTEM WITH THE CHANGING OUT IN KIND OF 1 - 225AMP PANEL AND 1 - 400AMP PANEL AND THE ADDITION OF 1 NEW 100AMP ELECTRICAL PANEL. THIS WORK WILL TAKE PLACE IN THE FRANKLIN AND JORDAN HALLS OF THE FRANKLIN INSTITUTE AS PER 2005 NEC (CC DISTRICT)"},{"number":"166665","date":"2008-07-24","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-12-14","scope":"PARTIAL CONCRETE SLAB REPAIRS MINOR OVERHEAD CHIPPING AND PATCHING TRAFFIC TOPPING"},{"number":"172359","date":"2008-09-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-08-28","scope":"REPLACEMENT OF 39 EXISTING PANELS AS PER 2005 NEC (CC DIST)"},{"number":"236805","date":"2009-09-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-03-08","scope":"INTERIOR ALTERATIONS AS PER PLANS"},{"number":"242026","date":"2009-10-14","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-02-09","scope":null},{"number":"237552","date":"2009-10-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-30","scope":"NEW LIGHT FIXTURES AND RECEPTS FOR MUSEUM DISPLAY, RE INSTALL EXISTING FIRE ALARM DEVICES IN NEW CEILING AND WALLS (CC DISTRICT)"},{"number":"248311","date":"2009-11-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-01-11","scope":"HISTORICAL COMMISSION REGISTERED PROPERTY. FOR THE RELOCATION OF 12 AUTO FIRE SPRINKLERS ON 2ND FLOOR OF THE FRANKLIN. NO CHANGES TO THE EXTERIOR ARE PERMITTED AS STATED BY THE PHC."},{"number":"281644","date":"2010-05-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-12-23","scope":"HOT AND COLD WATER PIPING AND DRAINAGE TO BAR SINK AND HAND SINK FOR TEMP.KIOSK,PEX WATER PIPING AND PVC FOR WASTE PIPING AS PER BG"},{"number":"20420","date":"2010-05-27","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2010-05-27","scope":"5/25/10-ERECTION OF (1)-15X20 COOK TENT"},{"number":"281920","date":"2010-05-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-12-08","scope":"FURNISH & INSTALL 4 QUAD GFI RECEPTACLES ON EXISTING CIRCUITS AS PER 2008 NEC (CC DISTRICT)"},{"number":"368451","date":"2011-10-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-10-18","scope":"REPAIR FRESH AIR INLET ON SANITARY HOUSE TRAP (OUTSIDE)(NORTH SIDE OF BLDG (WINTER STREET))"},{"number":"381570","date":"2012-02-27","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2014-05-07","scope":"PARTIAL DEMO OF EXISTING STRUCTURE, NEW ADDITION, ASSOCIATED DEMO AND INTERIOR /EXTERIOR ALTERATIONS, FACADE IMPROVEMENTS, CIVIL SITE WORK IMPROVEMENTS, LANDSCAPING,AS PER SUBMITTED PLANS. PHC HISTORICAL STAFF TO REVIEW CLADDING MATERIAL FOR APPROVAL.ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS."},{"number":"395649","date":"2012-04-03","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2013-01-09","scope":"REMOVAL OF ONE (1) 10,000 GALLON UST AND INSTALL ONE (1) 5,000 GALLON UST"},{"number":"398888","date":"2012-04-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-01-10","scope":"INSTALL STORM DETENTION BASIN 2-10\" STORM LATERALS, 1-8\" STORM LATERAL AND 2-6\" SANITARY LATERALS UP TO 5FT FROM BLDG (MUSEUM W/ GARAGE)"},{"number":"21536","date":"2012-04-18","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2012-04-18","scope":"TENTS [1] 9'X120' [1]30'X25' [8] 9'X20' [5] 9'X30' [1] 9'X30' [92]10'X10' FRANKLIN INSTITUTE AT LOGAN CIRCLE SCIENCE FESTIVAL"},{"number":"403676","date":"2012-06-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-12-27","scope":"REPLACING EXISTING COOLING TOWER AND ALL PIPING, REPLACING CHILLERS, PUMPS, ALL PIPING FOR MUSEUM AS PER PLAN."},{"number":"416771","date":"2012-07-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-01-17","scope":"RELOCATING (2) DRY PENDENT ON 1ST FLOOR OF MUSEUM."},{"number":"411236","date":"2012-08-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-03-04","scope":"NEW 4 STORY ADDITION WITH MEDIUM VOLTAGE TRANSFORMER FROM EXISTING PRIMARY SERVICE, LOW VOLT POWER DIST, BRANCH POWER AND LIGHTING, EXPANSION OF EXISTING FA SYSTEM, AND PATHWAYS FOR LOW VOLTAGE TELECOM SYSTEMS AS PER 2008 NEC & NFPA 72(MUSEUM)"},{"number":"431164","date":"2012-11-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-01-09","scope":"INSTALL SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 AS PER PLANS."},{"number":"457692","date":"2013-03-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-04-30","scope":"FURNISH AND INSTALL 1-120/208 VOLT 40 AMP FOR A ELECTRIC CHARGING STATION PER 2008 NEC (COMMERCIAL)"},{"number":"22256","date":"2013-04-16","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2013-04-16","scope":"ERECT 2 (30'X25') 3(30'X30') 1(20'X20') ASSEMBLY TENTS ON WINTER ST AT THE FRANKLIN INSTITUTE"},{"number":"460718","date":"2013-05-02","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2013-05-21","scope":"NEW OCCUPANCY SIGNAGE TO BE POSTED OUTSIDE OF FIVE (5) EXISITING ASSEMBLY AND STORAGE SPACES AT THE FRANKLIN INSTITUTE."},{"number":"479716","date":"2013-06-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-10-03","scope":"INSTALL FEEDER AND TEMPORARY FOR 100KV GENERATOR (06/28/2013-7/5/2013)PER 2008 NEC (TEMP POWER)"},{"number":"481007","date":"2013-08-14","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-01-09","scope":"AMEND PERMIT NUMBER 381570 TO INCLUDE ADDITIONAL REVISIONS, INTERIOR PARTITIONS AND NEW EXHIBITS IN SECOND FLOOR SPACE, INSTALLATION OF EXHIBITS, SCULPTURE, AS NOTED AND INDICATED. NO EXTERIOR WORK THIS PERMIT PER PHC"},{"number":"491044","date":"2013-08-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (6)60KW (6)100KW (2)230KW (2)TWIN 400KW (2)800KW AND (2)1000KW GENERATORS PER 2008 NEC (MUSEUM)"},{"number":"491046","date":"2013-08-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (2)234 KVW GENERATORS PER 2008 NEC (MUSEUM) (TEMP POWER FOR EVENT 8/23-9/3)"},{"number":"402970","date":"2013-10-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-12-27","scope":"NEW ADDITON TO THE FRANKLIN INSTITUTE"},{"number":"514242","date":"2014-01-07","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-01-10","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY FOR AP# 381570."},{"number":"528434","date":"2014-04-04","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-04-10","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY FOR AP# 381570 THIS IS THE 2ND TCO AND FINAL ONE."},{"number":"544292","date":"2014-06-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-08-20","scope":"INSTALL TEMPORARY 60KW GENERATOR FOR WAWA SHOW FROM JUNE 20 TO JUNE 23 2014 (MUSEUM)"},{"number":"546479","date":"2014-06-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL/REMOVE TEMPORARY GENERATORS FOR A TEMPORARY EVENT BEGINING 07/01/2014 AND ENDING 07/06/2014 - (7)GENERATORS: (2)TWIN 850KW, (3)25KW, (1)125KW & (1)325 KW - ALL WORK WILL BE IN COMPLIANCE WITH THE 2008 NEC"},{"number":"555863","date":"2014-08-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL TEMPORARY 40KW GENERATOR FOR AT&T MOBILE CELL SITE FROM 8/15/14 TO 8/21/2014 (ROMANS PARKING LOT)"},{"number":"555862","date":"2014-08-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL TEMPORARY 40KW GENERATOR FOR AT&T MOBILE CELL SITE FROM 8/15/14 TO 8/21/2014 (MUSEUM)"},{"number":"557423","date":"2014-08-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-09-27","scope":"INSTALL TEMPORARY GENERATORS FOR A TEMPORARY EVENT BEGINING 08/23/2014 AND ENDING 09/01/2014 - (16)GENERATORS: (2)1250KW, (4)220KW, (5)150KW, (4)125KW & (1)60 KW - ALL WORK WILL BE IN COMPLIANCE WITH THE 2008 NEC"},{"number":"558307","date":"2014-08-27","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-09-26","scope":"REPLACE SECTION OF COLLASPED LATERAL ON STORM WATER SYSTEM (COMM) SELF-CERIFICATION'S ARE NO LONGER PERMITTED - ALL EXCAVATIONS & PLUMBING TRENCHES IN EXCESS OF 5' IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"},{"number":"416761","date":"2014-09-12","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-09-12","scope":"CHANGING SIGN FACES TO EXISTING DOUBLE FACED ACCESSORY SIGN AND INSTALLATION OF (2) DIGITAL DISPLAY SIGN FACES. CHANGE EXISTING LOGO SIGN, ALL USING EXISTING SIGN STRUCTURE."},{"number":"596117","date":"2015-03-24","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-10-28","scope":"FOR INTERIOR ALTERATIONS TO ACCOMMODATE INSTALLATION OF A NEW ACCESSIBLE RAMP, FLOOR ELEVATION CHANGES, AND NEW FLOOR/CEILING/WALLS FINISHING. (IEBC 2009, COMPLIANCE PATH: WORK AREA METHOD, LVL I ALTERATIONS) ASBESTOS ABATEMENT TO BE COMPLETED PRIOR TO COMMENCEMENT OF PERMIT WORK SCOPE. SEPARATE PERMITS TO BE REQUIRED FOR ELECTRICAL WORK."},{"number":"599206","date":"2015-04-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-10-28","scope":"INTERIOR RENOVATIONS, FOR SPORTS CHALLENGE AREA AS PER PLANS."},{"number":"609537","date":"2015-05-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-08-15","scope":"TEMPORARY GENERATORS FOR AN EVENT 05.12.2015 THRU 05.19.2015 - (2)175KW, (1)1.1KW & (1)56 KW GENERATOR"},{"number":"612075","date":"2015-05-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"TEMPORARY POWER 3-100KW AND 1-56KW GENERATORS FOR EVENT (5/21/2015-5/23/2015)"},{"number":"617591","date":"2015-06-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"TEMPORARY CELL SITES 50KW GENERATOR PER 2008 NEC (MUSEUM) FOR AT&T EVENT 6/18/2015-7/16/2015"},{"number":"617584","date":"2015-06-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"TEMPORARY CELL SITES 50KW GENERATOR PER 2008 NEC (MUSEUM) FOR AT&T EVENT 6/18/2015-7/16/2015"},{"number":"619643","date":"2015-06-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"TEMP POWER 3-100KW AND 2-56KW FOR EVENT (MUSEUM)7/24/15-7/28/15"},{"number":"610387","date":"2015-07-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-30","scope":"3RD FLOOR, SPORTS CHALLENGE EXHIBIT ELECTRICAL ALTERATIONS - INSTALL NEW TRACK LIGHTING, (1)EXIT SIGN, RECEPTACLES, CABLE TRAY, TELE/DATA OUTLET BOX AND RACEWAY - REMOVE AND REMOUND THE EXISTING FIRE ALARM DEVICES ON NEW FINISHES - THE INSTALLATION WILL COMPLY WITH THE APPROVED PLANS, 2008 NEC AND THE NFPA 72"},{"number":"632978","date":"2015-08-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-11-01","scope":"REPLACE THREE BRADFORD-WHITE WATER HEATERS"},{"number":"635218","date":"2015-08-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"TEMP CELL SITE 50KW GENERATOR 9/18-9/30 GROUNDING FR TRAILER TEMP POWER AS PER 2008 NEC. (CENTER CITY DIST)"},{"number":"635202","date":"2015-08-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL TEMPORARY GENERATORS FOR TEMPORARY EVENT (MADE IN AMERICA) BEGINING 8-28-2015 AND ENDING 9-1-2015 16 GENERATORS:(2) 1250 KW, (4) 220KW,(5) 150KW. (4) 125KW (1)60KW AS PER 2008 NEC. (CENTER CITY DIST.)"},{"number":"635208","date":"2015-08-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"TEMPORY CELL SITE 50KW GENERATOR 9--18 TO 9-3 AS PER 2008 NEC. ( CENTER CITY DIST.)"},{"number":"646653","date":"2015-11-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RUN CONDUIT & POWER FOR AN EXTERIOR SIGN - SEE ZONING AP#416761 FOR CHANGING SIGN FACES TO EXISTING DOUBLE FACED ACCESSORY SIGN AND INSTALLATION OF (2) DIGITAL DISPLAY SIGN FACES. CHANGE EXISTING LOGO SIGN, ALL USING EXISTING SIGN STRUCTURE"},{"number":"716743","date":"2016-09-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-03-15","scope":"REPLACEMENT OF ONE EXT DOOR WITH ADA ACCESS. ALT TO INCLUDE INT AND PHC TO REVIEW CUT SHEETS/SHOP DRAWINGS OF EXT DOOR, DOOR TO MATCH EXSITING COLOR. ASBESTOS ABATEMENT TO COMPLETED PRIOR TO COMMENCEMENT OF WORK."},{"number":"715834","date":"2016-09-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-03-15","scope":"INSTALL NEW LIGHTING,POWER TO SUPPLY FAN,MOTOR OPERATED DOORS AND ASSOCIATED PUSHBUTTONS,REMOVE AND REMOUNT DOOR SECURITY DEVICES AS PER 2008 NEC (CC DISTRICT)"},{"number":"720351","date":"2016-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-03-15","scope":"FURNISH AND INSTALL 5 AIR DEVICES, DUCT & TRANSFER FAN FOR RENOVATES STUDENT ENTRANCE"},{"number":"772034","date":"2017-04-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"INSTALLATION OF ASME STORAGE TANK FOR WATER HEATER"},{"number":"767402","date":"2017-04-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-06-16","scope":"FOR PRESCRIPTIVE ALTERATIONS TO THE GROUND FLOOR, EAST WING EXHIBIT OF THE FRANKLIN INSTITUTE, AS PER PLANS AND PHC/ARTCOM APPROVAL; SEPARATE PERMITS REQUIRED FOR ANY AND ALL MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK; BUILDING IS FULLY SPRINKLERED."},{"number":"774660","date":"2017-04-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"776100","date":"2017-04-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"FURNISH AND INSTALL TWO TRANSFERS FANS AND DUCT WORK PERMIT DUCTWORK & WARM-AIR APPLIANCES IN EXITING SPACE TO NEW EXHIBIT- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"776964","date":"2017-04-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-12-03","scope":"INSTALL 112 CAT6 PLENUM DATA CABLES, LONGEST RUN 180'. TERMINATE, TEST AND LABEL ALL NEW CABLING. SUPPORT ALL NEW CABLING TO COMPLY WITH CODE.... IN ACCORDANCE WITH 2008 NEC (SCIENCE MUSEUM)"},{"number":"773582","date":"2017-06-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-18","scope":"RENOVATION TO EXISTING SPACE, INSTALL 15 LIGHT FIXTURES, 4 LIGHT SWITCH, 55 RECEPTS, 2 HVAC POWER AS PER 2008 NEC (CC DISTRICT)"},{"number":"776539","date":"2017-06-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"RENOVATION TO EXISTING SPACE (6) HORN/STROBES, (1) STROBE, (4) PHOTO/THERMAL DETECTORS AS PER NFPA72 (CC DISTRICT)"},{"number":"837207","date":"2017-12-06","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-03-01","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"821801","date":"2018-02-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-09","scope":"REPLACE CO CONTROL PANE AND SENSORS IN MUSEUM PARKING GARAGE USING EXISTING WIRING AS PER NEC 2008 CC DISTRICT"},{"number":"850788","date":"2018-02-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-10-16","scope":"WE WILL BE RELOCATING (1) SPRINKLERS WITHIN THE FRANKLIN INSTITUTE RESTROOM. EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"885853","date":"2018-06-14","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-09-28","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"886266","date":"2018-07-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-04","scope":"FURNISH AND INSTALL SMOKE DETECTORS AND RELAYS WITH NEW PANEL FOR ELEVATOR MODIFICATIONS PER NFPA 72"},{"number":"1000293","date":"2019-08-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-10-08","scope":"INSTALL POWER TO SHUNT-TRIP BREAKERS IN ACCORDANCE TO 2017 NEC (HOTEL)"},{"number":"GM-2023-003526","date":"2023-05-04","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2023-05-22","scope":"**Existing Philadelphia Historic Property** For the interior demolition of non-bearing partition walls and ceiling in accordance with the attached EZ Permit Interior Demolition Standard. Failure to comply with the attached EZ Permit Interior Demolition Standard shall result in revocation of this permit as per PHC. Demolition of approximately 50' of non load bearing drywall partition and flooring for a new exhibit."},{"number":"CP-2023-002632","date":"2023-05-19","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-12-20","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE FOR 2ND FLOOR AREA C - SPACE GALLERY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS AND PROVIDE FINISHES/FURNISHINGS. THE BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. FOR USE AS PREIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. ***************** SEPARATE PERMTIS TO BE OBTAINED FOR ALL OTHER WORK. ****************************************** AMENDMENT: Updated Special Inspection agency & inspection schedule."},{"number":"EP-2023-005820","date":"2023-06-22","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-01-04","scope":"Annual Maintenance Work. Maintain & Survey all electrical systems as needed. Routine maintenance as needed. Annual electrical maintenance permit to perform routine maintenance or replacement work on an already approved electrical system in an existing building includes replacement of lamps, broken switches, receptacles and fixtures as per 2017 NEC."},{"number":"EP-2023-006188","date":"2023-07-12","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-10-17","scope":"Demolition of existing, adding new power outlets in ceiling and walls, adding new feeders for HVAC. Adding (2) new 208V/120V panels and circuits for IT room as per 2017 NEC."},{"number":"EP-2023-007078","date":"2023-07-28","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-10-19","scope":"• Provide and install three (3) flush mount dual locations. • Provide and install eighteen (18) surface mount dual wireless access point locations. • Provide labor to install eighteen (18) customer-provided wireless access points. • Provide and install eighteen (18) surface mount single camera locations. • Provide and install twelve (12) 24-cable field “consolidation point” locations. • Provide and install twelve (12) CommScope 24-port modular patch panels, each loaded with twenty-four (24) CommScope Category 6A modular jacks. These will be installed as the field consolidation points and will terminate the twelve (12) 24-cable bundles. • Provide and install twelve (12) CommScope Category 6A 24-port patch panels. These will be installed at the appropriate consolidation point location in the ceiling space for termination of the consolidation point cables. • Provide and install twelve (12) CommScope 24-port modular patch panels, each loaded with the required modular jacks. These will be installed at the closet location for termination of the remaining horizontal cables installed. • Provide and install Belden 2-conductor 12 AWG wire for thirty-seven (37) speaker locations. These cables will be roughed-in only and left coiled and unterminated at each end for final terminations/connections by others. • Provide and install one (1) Belden Category 6+ enhanced F/UTP plenum rated 4-pair cable to Electrosonic networked device locations. Sixty-three (63) cables will be pulled from device locations to consolidation point patch panel above ceiling and eighteen (18) cables will be pulled from device locations to new IDF on Level 2. • Provide and install four (4) Belden 24-port modular patch panels, each loaded with the required modular jacks. These will be installed at the appropriate consolidation point location in the ceiling space for termination of the 4-pair cables installed. • Provide and install eighty-one (81) Belden Category 6 patch cords, 1’ in"},{"number":"CP-2023-003288","date":"2023-08-07","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-10-08","scope":"For level II alteration to the existing museum galleries as per approved plans. Building is fully sprinklered. Separate permits required for MEP and FP work. Asbestos to be removed prior to start of the work. Separate approval required from PA L & I for platform lift installation. Amendment to the Statement of Special Inspections Schedule to add Fire Resistance Penetrations and Joints. Amednment to the geometry of a rated wall, including rated glazing and structural supports."},{"number":"FP-2023-002291","date":"2023-10-02","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-11-13","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (7) sprinklers to accommodate interior alterations on 2nd floor, data room"},{"number":"EP-2023-007981","date":"2023-10-17","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-11-20","scope":"Install the following AV equipment: • One (1) 98\" display and one (1) 65\" display. • One (1) ceiling mounted projector. • One (1) camera for interactivity. Provide and install the following: • Second layer of unistrut for projectors. Miscellaneous: • Alignment of projectors and cameras. • Patch cables, HDMI cables and all associated pre-manufacturer cables between devices. • Assistance during commissioning. Facts of the Furture: • Four (4) 43\" displays within the fabrication. • Four (4) BrightSign Players. • Four (4) speakers above the displays. • Patch cables, HDMI cables and all associated pre-manufacturer cables between devices. • Terminations of speaker cabling. • Assistance during commissioning. Faster and Father: • Audio:Three (3) Tang Band Speakers installed in the case work. • Video Screen (320.V01): Three (3) non-interactive displays that fit into casework. • Overhead Artifact Case (320.V02): Two (2) non-interactive displays that fit into casework above the end-users. • Artifact Display Case Monitor (320.V03): Two (2) non-interactve displays that will fit into the casework for end users. • Interactive (320.V05): Three (3) non-interactive and three (3) interactive displays that will fit into casework. • Two (2) BrightSign Players. • One (1) SuperLogistics PC. • Patch cables, HDMI cables and all associated pre-manufacturer cables between devices. • Termination of speaker cabling. • Assistance during commissioning. PROPOSAL Remote Operation: • Audio: Four (4) Tang Band Speakers installed in the case work. • Video Monitor (353.V01): Four (4) 27in. ELO Touch screens around the table and two (2) local computers. • Overhead Projector (353.V04): One (1) overhead projector that will be within casework and will project down towards the table. • Monitors on a Scenic Shelf:One (1) 32in.Display and one (1) Brightsign player. • Patch cables, HDMI cables and all associated pre-manufacturer cables between devices. • Termination of speak"},{"number":"PP-2023-010838","date":"2023-10-26","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-10-08","scope":"Plumbing Permit (Interior) for combo CP-2023-003288"},{"number":"MP-2023-004527","date":"2023-11-03","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-11-13","scope":"To install 2 ductless split system as per approved plans."},{"number":"MP-2023-003416","date":"2023-11-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-10-08","scope":"Mechanical / Fuel Gas Permit for combo CP-2023-003288"},{"number":"EP-2023-007315","date":"2023-11-14","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-07-29","scope":"Electrical Permit for combo CP-2023-003288"},{"number":"FP-2023-002659","date":"2023-11-15","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-10-08","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (44) fire sprinkler heads from existing branch line outlets to accommodate new wall & ceiling layout."},{"number":"EP-2023-011612","date":"2023-12-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2025-04-08","scope":"Provide and install 185 cat6 plenum cables at 150' average. Provide and install 18/2 plenum cable to 11 speakers at 100' average. Provide and install 16/3 plenum cable to 10 AV locations at 150' average. All cabling will be installed per 2017 NEC. No rescue systems work."},{"number":"FP-2024-000038","date":"2024-01-09","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-10-08","scope":"FOR THE INSTALLATION OF 78 SPINKLER HEADS TIED INTO EXISTING AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH AN EXISTING BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS."},{"number":"GM-2024-004134","date":"2024-05-23","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2024-11-19","scope":"**Existing Philadelphia Historic Property** For the interior demolition of non-bearing partition walls and ceiling in accordance with the attached EZ Permit Interior Demolition Standard. Failure to comply with the attached EZ Permit Interior Demolition Standard shall result in revocation of this permit. No exterior work permitted as part of this permit as per PHC. (Franklin Institute 2nd Floor Gallery)"},{"number":"CP-2024-002766","date":"2024-06-12","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-12-19","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING SPACE ON THE 2ND FLOOR LEVEL. FOR USE AS PREVIOUSLY APPROVED. ALTERATIONS/ RENOVATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. THE BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"GM-2024-005250","date":"2024-06-17","work":"Annual Electrical Permit","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2024-12-23","scope":"Yearly Annual Electrical Maintenance Work. Maintain & Survey all electrical systems as needed. Routine maintenance as needed. PHC approval uploaded to application. No exterior work permitted as part of this permit."},{"number":"FP-2024-001493","date":"2024-07-17","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-12-19","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (18) sprinkler heads to accommodate interior alterations"},{"number":"EP-2024-006662","date":"2024-07-23","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-11-25","scope":"- Install ~500 low voltage cables - Install cable tray in IT Room Plenum cable, 250' longest run"},{"number":"EP-2024-006895","date":"2024-07-26","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-11-18","scope":"Demolition of existing circuits, relocation of existing lighting, adding circuits for new lighting and power, and raceways for LV as per 2017 NEC."},{"number":"EP-2024-007555","date":"2024-08-20","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-11","scope":"Install fire alarm as per plans and 2016 NFPA 72."},{"number":"MP-2024-005388","date":"2024-12-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-12-19","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2024-005323","date":"2025-01-03","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2026-05-05","scope":"FOR REPAIR TO AN EXISTING STRUCTURE (PORTION USED AS COMMERCIAL PARKING GARAGE). ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**PARKING GARAGE ONLY**"},{"number":"GM-2025-004499","date":"2025-06-06","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2025-07-15","scope":"EZ INTERIOR NON-LOAD-BEARING WALL DEMOLITION - For the interior demolition on NON-Load-Bearing partition walls and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. Structural alteration or repair is expressly PROHIBITED under this permit. Prohibited structural work includes but not limited to any modification to exterior walls, party wall, floor/roof framing and foundations, including underpinning, excavation and removal of foundation slab. Separate Streets Department permit required for sidewalk and street closures. Interior demolition of drywall partitions, furniture, and finishes."},{"number":"CP-2025-002629","date":"2025-07-11","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-10-20","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING RETAIL (MERCANTILE-M) SPACE, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2025-006755","date":"2025-07-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-09-25","scope":"Installation of seventeen (17) low voltage Category 6 computer wires as per NEC 2017."},{"number":"EP-2025-006757","date":"2025-08-15","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-09-18","scope":"INSTALL WIRING AND RELOCATE LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL LOW VOLTAGE WIRING. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS."},{"number":"GM-2026-000618","date":"2026-02-11","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2026-06-03","scope":"EZ INTERIOR NON-LOAD-BEARING WALL DEMOLITION - For the interior demolition on NON-Load-Bearing partition walls and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. Structural alteration or repair is expressly PROHIBITED under this permit. Prohibited structural work includes but not limited to any modification to exterior walls, party wall, floor/roof framing and foundations, including underpinning, excavation and removal of foundation slab. Separate Streets Department permit required for sidewalk and street closures."},{"number":"CP-2026-000552","date":"2026-04-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN USE AND OCCUPANCY CLASSIFICATION TO AN EXISTING GROUP A-3 MUSEUM GALLERY AND IT RACK ROOM AT THE 2ND FLOOR. EXISTING BUILDING IS SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2021 IEBC AND PHC APPROVAL. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. **ASBESTOS ABATEMENT REQUIRED.**"},{"number":"CP-2026-001411","date":"2026-06-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR STRUCTIRAL IMPROVEMENT TO A PORTION OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. **"},{"number":"PP-2026-008349","date":"2026-06-22","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Issued","completedDate":null,"scope":"Install (2) air lines and (1) hub drain, connecting to existing piping."},{"number":"EP-2026-006078","date":"2026-07-02","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"IT room and cabling plenum 250'"},{"number":"EP-2026-005221","date":"2026-07-10","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"Relocate existing power, install lighting circuits for new lighting and controls modify existing in-floor power to accept new raceways, installing (2) 120/208 panels. All work to be done according to the 2017 NEC and per approved plans."}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2025,"k":"viol","w":"16 L&I violations"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"insp","w":"L&I: 2 failed, 1 passed"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Interior Non-Load-Bearing Wall Demo."},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Alterations"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"appeal","w":"Appeal complete"}],"rented":false,"licenses":[{"number":"404262","type":"Public Garage / Parking Lot","status":"Inactive","businessName":"EXPERT PARKING MANAGEMENT INC","legalName":"EXPERT PARKING MANAGEMENT INC","address":"201 N 21ST ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2007-03-23","latestIssueDate":"2007-03-23","expirationDate":"2009-06-30","inactiveDate":"2007-04-05"},{"number":"342082","type":"Public Garage / Parking Lot","status":"Inactive","businessName":"EXPERT PARKING INC","legalName":"EXPERT PARKING INC","address":"201 N 21ST ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2007-04-05","latestIssueDate":"2014-02-08","expirationDate":"2014-12-31","inactiveDate":"2015-03-01"},{"number":"492156","type":"Food Caterer","status":"Inactive","businessName":"THE COMMISSARY INC. (FROG COMMISSARY)","legalName":"THE COMMISSARY INC.","address":"201 N 21ST ST","revenueCode":"3122","rentalCategory":null,"units":null,"issuedDate":"2010-01-21","latestIssueDate":"2020-04-07","expirationDate":"2021-04-30","inactiveDate":"2021-06-29"},{"number":"515029","type":"Dumpster License - Private Property","status":"Active","businessName":"THE FRANKLIN INSTITUTE","legalName":"THE FRANKLIN INSTITUTE","address":"201 N 21ST ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2010-09-21","latestIssueDate":"2013-08-03","expirationDate":null,"inactiveDate":null},{"number":"727120","type":"Monthly Small Games of Chance","status":"Inactive","businessName":"MUSICOPIA INC","legalName":"MUSICOPIA INC","address":"201 N 21ST ST","revenueCode":"3844","rentalCategory":null,"units":null,"issuedDate":"2017-01-31","latestIssueDate":"2017-01-31","expirationDate":"2017-07-30","inactiveDate":null},{"number":"764712","type":"Monthly Small Games of Chance","status":"Inactive","businessName":"MUSICOPIA INC","legalName":"MUSICOPIA INC","address":"201 N 21ST ST","revenueCode":"3844","rentalCategory":null,"units":null,"issuedDate":"2018-02-02","latestIssueDate":"2018-02-02","expirationDate":"2018-08-01","inactiveDate":null},{"number":"764717","type":"Monthly Small Games of Chance","status":"Inactive","businessName":"ARTS IN SCHOOLS COLLABORATIVE","legalName":"ARTS IN SCHOOLS COLLABORATIVE","address":"201 N 21ST ST","revenueCode":"3844","rentalCategory":null,"units":null,"issuedDate":"2018-02-02","latestIssueDate":"2018-02-02","expirationDate":"2018-08-01","inactiveDate":null},{"number":"788440","type":"Food Establishment, Retail Permanent Location","status":"Active","businessName":"Event Network, LLC (Franklin Institute Gift Shop)","legalName":"Event Network, LLC","address":"201 N 21ST ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2018-09-07","latestIssueDate":"2025-08-20","expirationDate":"2026-09-06","inactiveDate":null},{"number":"0971325","type":"Public Garage / Parking Lot","status":"Active","businessName":"SP Plus Corporation (Management)","legalName":"SP Plus Corporation","address":"201 N 21ST ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2025-02-11","latestIssueDate":"2026-03-09","expirationDate":"2027-02-10","inactiveDate":null},{"number":"0986394","type":"Food Preparing and Serving (30+ SEATS)","status":"Active","businessName":"Levy Premium Food Service, LP","legalName":"Levy Premium Food Service, LP","address":"201 N 21ST ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2025-08-15","latestIssueDate":"2025-08-15","expirationDate":"2026-08-14","inactiveDate":null}],"licenseActivity":[{"number":"0986394","type":"Food Preparing and Serving (30+ SEATS)","businessName":"Levy Premium Food Service, LP","legalName":"Levy Premium Food Service, LP","issuedDate":"2025-08-15","latestIssueDate":"2025-08-15","closureDate":null,"expirationDate":"2026-08-14","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"0971325","type":"Public Garage / Parking Lot","businessName":"SP Plus Corporation (Management)","legalName":"SP Plus Corporation","issuedDate":"2025-02-11","latestIssueDate":"2026-03-09","closureDate":null,"expirationDate":"2027-02-10","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"788440","type":"Food Establishment, Retail Permanent Location","businessName":"Event Network, LLC (Franklin Institute Gift Shop)","legalName":"Event Network, LLC","issuedDate":"2018-09-07","latestIssueDate":"2025-08-20","closureDate":null,"expirationDate":"2026-09-06","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"764717","type":"Monthly Small Games of Chance","businessName":"ARTS IN SCHOOLS COLLABORATIVE","legalName":"ARTS IN SCHOOLS COLLABORATIVE","issuedDate":"2018-02-02","latestIssueDate":"2018-02-02","closureDate":"2018-08-01","expirationDate":"2018-08-01","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"764712","type":"Monthly Small Games of Chance","businessName":"MUSICOPIA INC","legalName":"MUSICOPIA INC","issuedDate":"2017-01-31","latestIssueDate":"2018-02-02","closureDate":"2018-08-01","expirationDate":"2018-08-01","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"515029","type":"Dumpster License - Private Property","businessName":"THE FRANKLIN INSTITUTE","legalName":"THE FRANKLIN INSTITUTE","issuedDate":"2010-09-21","latestIssueDate":"2013-08-03","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"492156","type":"Food Caterer","businessName":"THE COMMISSARY INC. (FROG COMMISSARY)","legalName":"THE COMMISSARY INC.","issuedDate":"2010-01-21","latestIssueDate":"2020-04-07","closureDate":"2021-06-29","expirationDate":"2021-04-30","inactiveDate":"2021-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"342082","type":"Public Garage / Parking Lot","businessName":"EXPERT PARKING INC","legalName":"EXPERT PARKING INC","issuedDate":"2007-04-05","latestIssueDate":"2014-02-08","closureDate":"2015-03-01","expirationDate":"2014-12-31","inactiveDate":"2015-03-01","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"404262","type":"Public Garage / Parking Lot","businessName":"EXPERT PARKING MANAGEMENT INC","legalName":"EXPERT PARKING MANAGEMENT INC","issuedDate":"2007-03-23","latestIssueDate":"2007-03-23","closureDate":"2007-04-05","expirationDate":"2009-06-30","inactiveDate":"2007-04-05","status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"record-pressure","level":"elevated","title":"Records to verify together","summary":"More than one separately dated public record deserves a current-status check.","evidence":["16 open L&I violations","failed L&I inspection activity in 2022, 2025"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."},{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["9 permit events since 2023","1 zoning/board appeal since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"building-certifications","level":"urgent","title":"A life-safety certification is deficient","finding":"Facade Report: Safe with Repair through Sep 24, 2030; Special Hazards Certification: Certified through Apr 22, 2027; Sprinkler Certification: Deficient; Fire Alarm Certification: Certified through Jan 20, 2027; Emergency and Standby Power Systems Certification: Certified through May 11, 2027","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Appeal #12171: CLOSED · Granted with conditions; related permit 283271. Use permit #416761: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"7 permits not marked completed: EP-2023-011612 (Expired), CP-2024-005323 (Expired), CP-2026-000552 (Issued), CP-2026-001411 (Issued), PP-2026-008349 (Issued). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"16 open L&I violations","finding":"36 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"16 failed, 9 passed, and 0 CLOSED investigation outcomes are in the fetched history; the latest dated visit was FAILED on Dec 4, 2025.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Public Garage / Parking Lot #404262: Inactive since Apr 5, 2007; Public Garage / Parking Lot #342082: Inactive since Mar 1, 2015; Food Caterer #492156: Inactive since Jun 29, 2021; Monthly Small Games of Chance #727120: Inactive","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"abatement","level":"verify","title":"A reduced taxable assessment is not a verified abatement","finding":"OPA’s numeric assessment fields show a reduced taxable assessment; BlockReport has no official program determination for this parcel.","why":"The numeric treatment can reflect an improvement abatement or another exemption. It does not identify the ordinance, approval, start or end date, or continuation requirements after a transfer. Once OPA verifies a specific active abatement, many common programs attach the benefit to the property for the remaining term rather than ending automatically at sale, but some require a new-owner filing and continued qualifying use or tax compliance.","action":"Obtain the OPA exemption/abatement determination and history, then underwrite the buyer’s bill from the verified program terms.","url":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/get-a-property-tax-abatement/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as commercial. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}