{"asOf":"2026-07-29T02:21:19.972Z","block":"5100-5199 W THOMPSON ST","blockUrl":"https://philadelphia.blockreport.homes/block/5100-5199-w-thompson-st","address":"5162-64 W THOMPSON ST","parcelNumber":"871569400","source":"https://property.phila.gov/?p=871569400","ownerType":"investor","kind":"mixed-use","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"Y50","buildingCodeNew":"817","buildingClass":"STR/OFF+APT 3 STY MASONRY","buildingClassNew":"DET MIXED-COM/RES-BLT AS COM","useLabel":"Apartment building","owner":"DREAMCHASERS LLC","coOwner":null,"marketValue":245300,"landAssessment":49000,"improvementAssessment":196300,"livableArea":6630,"yearBuilt":1925,"lastSale":{"price":1,"date":"2013-07-16T04:00:00Z"},"openViolations":5,"violations":[{"number":"2555815","date":"2012-05-09","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2555813","date":"2012-05-09","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2555816","date":"2012-05-09","code":"PM-306.2/1","title":"VACANT BLDG UNSECURED COUNT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2555814","date":"2012-05-09","code":"PM-304.4/1","title":"EXT S-ROOF REPAIR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3466002","date":"2015-02-05","code":"PM-306.2/1","title":"VACANT BLDG UNSECURED COUNT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3670332","date":"2015-02-06","code":"PM-304.8/16","title":"EXT S-WINDOW REPAIR/REPLACE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3670330","date":"2015-02-06","code":"PM-102.4/4","title":"LICENSE-VAC COMM BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3670331","date":"2015-02-06","code":"PM-304.5/1","title":"EXT S-ACC DEV REPAIR/MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3817021","date":"2015-03-03","code":"PM-307.1/9","title":"WALL FRACTURED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817017","date":"2015-03-03","code":"PM-307.1/1","title":"VACANT PROP UNSAFE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817018","date":"2015-03-03","code":"PM-307.1/2","title":"ROOF DETERIORATED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817019","date":"2015-03-03","code":"PM-307.1/20","title":"SIGN-UNSAFE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817020","date":"2015-03-03","code":"PM-307.1/8","title":"WALL BULGED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"4253610","date":"2015-08-31","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3990651","date":"2016-06-23","code":"PM15-302.1","title":"EXTERIOR AREA SANITATION","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3990650","date":"2016-06-23","code":"PM15-108.2","title":"VACANT AND OPEN","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3990652","date":"2016-06-23","code":"PM15-302.4","title":"EXTERIOR AREA WEEDS","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"4449291","date":"2016-06-23","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"211942544","date":"2017-11-20","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":"2023-04-04","resolution":"COMPLIED - PERMIT OBTAINED"},{"number":"4954746","date":"2018-11-15","code":"PM15-304.1B","title":"EXTERIOR STRUCT UNSAFE COND 2","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4954748","date":"2018-11-15","code":"PM15-304.1H","title":"EXTERIOR STRUCT UNSAFE COND 8","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4954747","date":"2018-11-15","code":"PM15-304.1G","title":"EXTERIOR STRUCT UNSAFE COND 7","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4954745","date":"2018-11-15","code":"PM15-108.1","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2020-043256","date":"2020-10-20","code":"A-301.1/54","title":"NEW PLUMBING","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043255","date":"2020-10-20","code":"A-301.6/1","title":"PLANS REQUIRED TO COMPLY","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043254","date":"2020-10-20","code":"A-301.1/46","title":"HVAC SYSTEM","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043252","date":"2020-10-20","code":"A-301.1/4","title":"ALTER INTERIOR PORTION","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043253","date":"2020-10-20","code":"A-301.1/50","title":"NEW ELECTRICAL WIRING","status":"OPEN","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"328544","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2012-05-17","completedDate":"2012-12-12","violations":[{"number":"2555815","date":"2012-05-09","code":"PM-306.0/1","title":"VACANT PROP STANDARD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2555813","date":"2012-05-09","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2555816","date":"2012-05-09","code":"PM-306.2/1","title":"VACANT BLDG UNSECURED COUNT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2555814","date":"2012-05-09","code":"PM-304.4/1","title":"EXT S-ROOF REPAIR","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"468040","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-02-06","completedDate":"2015-04-10","violations":[{"number":"3466002","date":"2015-02-05","code":"PM-306.2/1","title":"VACANT BLDG UNSECURED COUNT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"468045","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-02-06","completedDate":"2016-07-20","violations":[{"number":"3670332","date":"2015-02-06","code":"PM-304.8/16","title":"EXT S-WINDOW REPAIR/REPLACE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3670330","date":"2015-02-06","code":"PM-102.4/4","title":"LICENSE-VAC COMM BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3670331","date":"2015-02-06","code":"PM-304.5/1","title":"EXT S-ACC DEV REPAIR/MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"470196","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2015-03-04","completedDate":"2018-12-14","violations":[{"number":"3817021","date":"2015-03-03","code":"PM-307.1/9","title":"WALL FRACTURED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817017","date":"2015-03-03","code":"PM-307.1/1","title":"VACANT PROP UNSAFE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817018","date":"2015-03-03","code":"PM-307.1/2","title":"ROOF DETERIORATED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817019","date":"2015-03-03","code":"PM-307.1/20","title":"SIGN-UNSAFE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3817020","date":"2015-03-03","code":"PM-307.1/8","title":"WALL BULGED","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"498268","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-08-20","completedDate":"2017-05-06","violations":[{"number":"4253610","date":"2015-08-31","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"541574","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-06-27","completedDate":"2016-09-27","violations":[{"number":"3990651","date":"2016-06-23","code":"PM15-302.1","title":"EXTERIOR AREA SANITATION","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3990650","date":"2016-06-23","code":"PM15-108.2","title":"VACANT AND OPEN","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3990652","date":"2016-06-23","code":"PM15-302.4","title":"EXTERIOR AREA WEEDS","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"541576","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-06-27","completedDate":null,"violations":[{"number":"4449291","date":"2016-06-23","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"603847","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PROPERTY MAINTENANCE INVESTIGATOR","status":"CLOSED","createdDate":"2017-09-13","completedDate":"2023-04-04","violations":[{"number":"211942544","date":"2017-11-20","code":"9-3905","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":"2023-04-04","resolution":"COMPLIED - PERMIT OBTAINED"}]},{"number":"663921","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2018-11-15","completedDate":"2020-02-14","violations":[{"number":"4954746","date":"2018-11-15","code":"PM15-304.1B","title":"EXTERIOR STRUCT UNSAFE COND 2","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4954748","date":"2018-11-15","code":"PM15-304.1H","title":"EXTERIOR STRUCT UNSAFE COND 8","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4954747","date":"2018-11-15","code":"PM15-304.1G","title":"EXTERIOR STRUCT UNSAFE COND 7","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4954745","date":"2018-11-15","code":"PM15-108.1","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2020-073925","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"BUILDING INVESTIGATOR","status":"IN VIOLATION","createdDate":"2020-10-20","completedDate":null,"violations":[{"number":"VI-2020-043256","date":"2020-10-20","code":"A-301.1/54","title":"NEW PLUMBING","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043255","date":"2020-10-20","code":"A-301.6/1","title":"PLANS REQUIRED TO COMPLY","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043254","date":"2020-10-20","code":"A-301.1/46","title":"HVAC SYSTEM","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043252","date":"2020-10-20","code":"A-301.1/4","title":"ALTER INTERIOR PORTION","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2020-043253","date":"2020-10-20","code":"A-301.1/50","title":"NEW ELECTRICAL WIRING","status":"OPEN","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2012,"n":4,"worst":null},{"y":2015,"n":10,"worst":"VACANT PROP UNSAFE"},{"y":2016,"n":4,"worst":null},{"y":2017,"n":1,"worst":null},{"y":2018,"n":4,"worst":"EXTERIOR STRUCT UNSAFE COND 2"},{"y":2020,"n":5,"worst":null}],"investigations":[{"caseNumber":"328544","date":"2012-05-09","type":"CI INSP","status":"FAILED"},{"caseNumber":"328544","date":"2012-08-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"328544","date":"2012-12-11","type":"CI INSP","status":"CLOSED"},{"caseNumber":"468040","date":"2015-02-05","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"468045","date":"2015-02-05","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"468040","date":"2015-02-23","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"470196","date":"2015-03-03","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"468045","date":"2015-03-16","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"468045","date":"2015-04-21","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"468045","date":"2015-08-07","type":"PRECOURT","status":"FAILED"},{"caseNumber":"468045","date":"2015-08-20","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"470196","date":"2015-11-14","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"470196","date":"2016-01-04","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"541574","date":"2016-06-23","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"541576","date":"2016-06-23","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"541574","date":"2016-09-08","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"470196","date":"2016-09-16","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"541576","date":"2017-02-04","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"498268","date":"2017-03-21","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"541576","date":"2017-03-29","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"498268","date":"2017-05-06","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"541576","date":"2017-09-12","type":"PRECOURT","status":"FAILED"},{"caseNumber":"541576","date":"2017-09-13","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"603847","date":"2017-11-20","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"603847","date":"2018-11-02","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"470196","date":"2018-11-14","type":"CSUINITIAL","status":"CLOSED"},{"caseNumber":"663921","date":"2018-11-15","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"663921","date":"2019-02-15","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"663921","date":"2020-02-14","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"CF-2020-073925","date":"2020-10-20","type":null,"status":"FAILED"},{"caseNumber":"CF-2020-073925","date":"2021-04-14","type":null,"status":"FAILED"},{"caseNumber":"CF-2020-073925","date":"2021-05-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2020-073925","date":"2021-08-02","type":null,"status":"FAILED"},{"caseNumber":"CF-2020-073925","date":"2021-10-19","type":null,"status":"FAILED"},{"caseNumber":"CF-2020-073925","date":"2022-05-26","type":null,"status":"FAILED"},{"caseNumber":"603847","date":"2023-04-04","type":null,"status":"PASSED"}],"inspYears":[{"y":2012,"fails":2,"passes":0},{"y":2015,"fails":6,"passes":0},{"y":2016,"fails":4,"passes":0},{"y":2017,"fails":4,"passes":1},{"y":2018,"fails":2,"passes":0},{"y":2019,"fails":1,"passes":0},{"y":2020,"fails":1,"passes":1},{"y":2021,"fails":4,"passes":0},{"y":2022,"fails":1,"passes":0},{"y":2023,"fails":0,"passes":1}],"taxOwed":24465.49,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":true,"totalDue":24465.49,"principalDue":14816.76,"penaltyDue":1019.01,"interestDue":3980.98,"otherChargesDue":4648.74,"yearsOwed":7,"oldestYearOwed":1997,"mostRecentYearOwed":2021,"mostRecentPaymentDate":"2021-07-27","assessmentYear":2022,"totalAssessment":112700,"taxableAssessment":112700,"exemptAbatementAssessment":0,"homesteadValue":0,"netTaxAfterHomestead":1577.57,"actionableAtSnapshot":true,"paymentAgreementAtSnapshot":false,"bankruptcyAtSnapshot":false,"assessmentUnderAppealAtSnapshot":false,"yearMonth":"202206"},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.97282253212372,"lng":-75.22568123909858,"geom":{"type":"Polygon","coordinates":[[[-75.225608327,39.972714424],[-75.225712843,39.972703393],[-75.225753173,39.972931178],[-75.225649928,39.972942383],[-75.225608327,39.972714424]]]},"liDistrict":"CENTRAL WEST","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19131","beds":null,"baths":null,"stories":3,"lotArea":2540,"zoning":"CMX2","grade":"C","basement":null,"heater":null,"centralAir":null,"extCond":"7","intCond":"7","garage":null,"homestead":false,"mail":"3651 PEACHTREE PKWY, SUWANEE GA, 30024","mailOut":true,"appeals":[],"taxYears":[{"year":1997,"total":300,"principal":0,"interest":0,"penalty":0},{"year":2014,"total":2600.39,"principal":1673.53,"interest":326.34,"penalty":117.15},{"year":2015,"total":2422.66,"principal":1673.53,"interest":175.72,"penalty":117.15},{"year":2016,"total":1991.33,"principal":1748.21,"interest":26.22,"penalty":17.48}],"taxNet":7314.38,"taxLien":true,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":108600,"taxable":108600,"land":12545,"improvement":96055,"taxableLand":12545,"taxableImprovement":96055,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":108600,"taxable":108600,"land":12545,"improvement":96055,"taxableLand":12545,"taxableImprovement":96055,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":252700,"taxable":252700,"land":50540,"improvement":202160,"taxableLand":50540,"taxableImprovement":202160,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":260200,"taxable":260200,"land":52514,"improvement":207686,"taxableLand":52514,"taxableImprovement":207686,"exemptLand":0,"exemptImprovement":0},{"y":2020,"v":112700,"taxable":112700,"land":22500,"improvement":90200,"taxableLand":22500,"taxableImprovement":90200,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":112700,"taxable":112700,"land":22500,"improvement":90200,"taxableLand":22500,"taxableImprovement":90200,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":112700,"taxable":112700,"land":22500,"improvement":90200,"taxableLand":22500,"taxableImprovement":90200,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":198900,"taxable":198900,"land":39700,"improvement":159200,"taxableLand":39700,"taxableImprovement":159200,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":198900,"taxable":198900,"land":39700,"improvement":159200,"taxableLand":39700,"taxableImprovement":159200,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":197400,"taxable":197400,"land":39480,"improvement":157920,"taxableLand":39480,"taxableImprovement":157920,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":197400,"taxable":197400,"land":39480,"improvement":157920,"taxableLand":39480,"taxableImprovement":157920,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":245300,"taxable":245300,"land":49000,"improvement":196300,"taxableLand":49000,"taxableImprovement":196300,"exemptLand":0,"exemptImprovement":0}],"taxNow":2763,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"975000","date":"2019-06-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-02-14","scope":"MAKE SAFE PERMIT - FOR REMOVAL OF ROOF RAFTERS AND FILLING JOIST POCKET WITH GROUT, INSTALL 2\"X12\"LEDGER BOARDS WITH 3/4\" WEDGE ANCHORS STAGGERED 24\" O.C. WITH 5\" MINIMUM EMBEDMENT, INSTALL 2\"X12\" RAFTERS SPANNING FROM LEDGER BOARDS USING SIMPSON STRONG-TIE JOIST HANGERS AND APPROVED SIMPSON HDWR TO EXISTING STEEL BEAMS, REMOVE/REPLACE COLLAPSED 2ND FLOOR JOISTS (REAR) IN-KIND, EXTERIOR FRONT WALL REPAIR MASONRY AND REPOINT THE EXTERIOR FRONT FACADE. PER ENGINEER'S REPORT/PLAN TO RESOLVE CASE #663921. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6' IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #663921. *CONTRACTOR HAS NO EMPLOYEES PER NOTARIZED LETTER*"},{"number":"ZP-2021-015743","date":"2022-03-02","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Vacant; Residential - Household Living - Multi-Family"},{"number":"CP-2021-007159","date":"2022-05-04","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-05-12","scope":"FOR INTERIOR ALTERATIONS TO INCLUDE INTERIOR PARTITION WALL RECONFIGURATIONS, AND WALL/FLOOR/CEILING FINISHING. (IEBC 2018, WORK-AREA METHOD, LVL II ALTERATIONS) **SEPARATE PERMIT REQUIRED FOR FIT-OUT OF GROUND FLOOR TENANT SPACE. SEPARATE PERMITS TO BE REQUIRED FOR ANY WORK FOR ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM INSTALLATIONS/ALTERATIONS.**"},{"number":"CP-2023-004329","date":"2023-10-03","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2024-05-29","scope":"FOR LEVEL II ALTERATIONS TO INCLUDE INTERIOR PARTITION WALL RECONFIGURATIONS, AND WALL/FLOOR/CEILING FINISHING. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 **SEPARATE PERMIT REQUIRED FOR FIT-OUT OF GROUND FLOOR TENANT SPACE. SEPARATE PERMITS TO BE REQUIRED FOR ANY WORK FOR ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM INSTALLATIONS/ALTERATIONS.**"}],"storyTag":"Improved","storyDelta":null,"timeline":[{"y":2016,"k":"viol","w":"4 L&I violations"},{"y":2017,"k":"viol","w":"L&I violation"},{"y":2018,"k":"viol","w":"4 L&I violations incl EXTERIOR STRUCT UNSAFE COND 2"},{"y":2019,"k":"permit","w":"Major alteration"},{"y":2020,"k":"viol","w":"5 L&I violations"},{"y":2020,"k":"insp","w":"L&I: 1 failed, 1 passed"},{"y":2021,"k":"insp","w":"Inspection failed ×4"},{"y":2022,"k":"permit","w":"Change of Use"},{"y":2022,"k":"permit","w":"Addition and/or Alteration"},{"y":2022,"k":"insp","w":"Inspection failed"},{"y":2023,"k":"insp","w":"Inspection passed"},{"y":2023,"k":"permit","w":"Addition and/or Alteration"}],"rented":false,"licenses":[],"licenseActivity":[],"businessLicenseSourceDate":"2026-07-28","signals":[{"kind":"record-pressure","level":"strong","title":"Records to verify together","summary":"Several independent, separately dated records stack up here and deserve prompt verification.","evidence":["5 open L&I violations","$24,465 appeared in the City's June 2022 delinquency snapshot","a lien number appears in the historical tax ledger through 2016","failed L&I inspection activity in 2021, 2022"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"The record identifies more than one dwelling/use.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"2 permits not marked completed: CP-2021-007159 (Expired), CP-2023-004329 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"5 open L&I violations","finding":"28 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"dated-tax-balance","level":"attention","title":"A dated tax balance needs a current payoff","finding":"$24,465.49 was recorded in the City’s 2022-06 delinquency snapshot for 1997–2021.","why":"That is historical evidence, not today’s amount due. A current exemption, payment, credit, or assistance agreement can coexist with an older snapshot row.","action":"Check period balances and request a dated Property Payoff statement for settlement.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"id":"mixed-use","level":"verify","title":"Residential and business space run on separate compliance tracks","finding":"OPA classifies this parcel as mixed-use.","why":"The zoning/use and occupancy file must cover the actual residential and commercial spaces. Dwelling units can require Rental Licenses and lead compliance; the operator can separately need an Activity License and sector license; installed fire systems can require annual certification.","action":"Match every dwelling and business use to the zoning permit, CO, current operator licenses, and life-safety filings.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"rental-status","level":"verify","title":"Residential form does not establish rental use","finding":"OPA classifies the parcel as mixed-use; no active Rental License row matched.","why":"A multi-unit or mixed-use classification does not prove that space is currently rented. If dwelling space is rented, Philadelphia generally requires a current Rental License and related occupancy, tax, violation, and lead compliance.","action":"Confirm actual occupancy first; if any unit is rented, verify the license and legal unit count with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"25 failed, 3 passed, and 8 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Apr 4, 2023.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"verify","title":"A fire-system permit exists, but no annual certification matched","finding":"2 fire/suppression-related permits matched; the fetched BIN certification feed returned no row.","why":"Installed systems in mixed-use and larger buildings generally require periodic certification, but applicability and limited-area exceptions vary. A missing BIN/address join is not proof of a compliance failure.","action":"Confirm what system was installed and whether a current annual certificate is required and filed.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as mixed-use. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}