{"asOf":"2026-07-25T13:19:10.647Z","block":"1700-1799 S 2ND ST","blockUrl":"https://philadelphia.blockreport.homes/block/1700-1799-s-2nd-st","address":"1728-32 S 2ND ST","parcelNumber":"881002128","source":"https://property.phila.gov/?p=881002128","ownerType":"investor","kind":"multi-family","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"CA0","buildingCodeNew":"804","buildingClass":"APTS 5-50 UNITS MASONRY","buildingClassNew":"APARTMENTS - LOW RISE","useLabel":"Apartment building","owner":"1728 S 2ND ST PARTNERS LL","coOwner":null,"marketValue":2506500,"landAssessment":250600,"improvementAssessment":2255900,"livableArea":18828,"yearBuilt":1915,"lastSale":{"price":550000,"date":"2017-05-01T04:00:00Z"},"openViolations":0,"violations":[{"number":"1607383","date":"2009-09-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1607382","date":"2009-09-24","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1607381","date":"2009-09-24","code":"FC-907.3/3","title":"FA-REQ¿D EXIST GROUP SPEC A","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1607384","date":"2009-11-04","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935333","date":"2010-06-21","code":"FC-408.2/1","title":"FIRE/EVAC PLN-GROUP A-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935334","date":"2010-06-21","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935339","date":"2010-06-22","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935343","date":"2010-06-22","code":"FC-904.2/1","title":"AFES-COMM KITCH EXHAUST REQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935337","date":"2010-06-22","code":"FC-405.5/1","title":"EVAC DRILL-RECORD CONTENT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935336","date":"2010-06-22","code":"FC-405.2/1","title":"EVAC DRILL-GRP A-CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935335","date":"2010-06-22","code":"FC-105.7/1","title":"FA/SUPP INSTALL PERMIT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935346","date":"2010-06-22","code":"FC-1006.1/1","title":"EGRESS LIGHTING REQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935338","date":"2010-06-22","code":"FC-406.1/1","title":"FIRE/EVAC PLN-EMPLY TRNG DUTY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935342","date":"2010-06-22","code":"FC-805.1/3","title":"FIRE-CURTAINS/DRAPES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935341","date":"2010-06-22","code":"FC-409.5/1","title":"SHELTER DRILL CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935340","date":"2010-06-22","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935344","date":"2010-06-22","code":"FC-904.11/5","title":"FIRE EXTING-INSTALL TYPE K","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935345","date":"2010-06-22","code":"FC-907.3/3","title":"FA-REQ¿D EXIST GROUP SPEC A","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3825863","date":"2016-01-21","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3860896","date":"2016-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3860898","date":"2016-01-20","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3860897","date":"2016-01-20","code":"FC-604.1/1","title":"UNIT STORAGE BATTERY SYS TEST","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4024507","date":"2016-03-07","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4024506","date":"2016-03-07","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4024508","date":"2016-03-07","code":"PM15-604.3","title":"ELECTRICAL -HAZARD","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"215568","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2009-09-25","completedDate":"2013-12-24","violations":[{"number":"1607383","date":"2009-09-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1607382","date":"2009-09-24","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1607381","date":"2009-09-24","code":"FC-907.3/3","title":"FA-REQ¿D EXIST GROUP SPEC A","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1607384","date":"2009-11-04","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"240344","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2010-06-22","completedDate":"2011-01-20","violations":[{"number":"1935333","date":"2010-06-21","code":"FC-408.2/1","title":"FIRE/EVAC PLN-GROUP A-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935334","date":"2010-06-21","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935339","date":"2010-06-22","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935343","date":"2010-06-22","code":"FC-904.2/1","title":"AFES-COMM KITCH EXHAUST REQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935337","date":"2010-06-22","code":"FC-405.5/1","title":"EVAC DRILL-RECORD CONTENT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935336","date":"2010-06-22","code":"FC-405.2/1","title":"EVAC DRILL-GRP A-CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935335","date":"2010-06-22","code":"FC-105.7/1","title":"FA/SUPP INSTALL PERMIT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935346","date":"2010-06-22","code":"FC-1006.1/1","title":"EGRESS LIGHTING REQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935338","date":"2010-06-22","code":"FC-406.1/1","title":"FIRE/EVAC PLN-EMPLY TRNG DUTY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935342","date":"2010-06-22","code":"FC-805.1/3","title":"FIRE-CURTAINS/DRAPES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935341","date":"2010-06-22","code":"FC-409.5/1","title":"SHELTER DRILL CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935340","date":"2010-06-22","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935344","date":"2010-06-22","code":"FC-904.11/5","title":"FIRE EXTING-INSTALL TYPE K","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1935345","date":"2010-06-22","code":"FC-907.3/3","title":"FA-REQ¿D EXIST GROUP SPEC A","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"517272","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-01-21","completedDate":"2016-04-28","violations":[{"number":"3825863","date":"2016-01-21","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"517275","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-01-21","completedDate":"2016-04-07","violations":[{"number":"3860896","date":"2016-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3860898","date":"2016-01-20","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3860897","date":"2016-01-20","code":"FC-604.1/1","title":"UNIT STORAGE BATTERY SYS TEST","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"522743","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-03-07","completedDate":null,"violations":[{"number":"4024507","date":"2016-03-07","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4024506","date":"2016-03-07","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4024508","date":"2016-03-07","code":"PM15-604.3","title":"ELECTRICAL -HAZARD","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2009,"n":4,"worst":null},{"y":2010,"n":14,"worst":null},{"y":2016,"n":7,"worst":null}],"investigations":[{"caseNumber":"87120","date":"2006-10-26","type":"CI INSP","status":"FAILED"},{"caseNumber":"87120","date":"2009-09-24","type":"CI INSP","status":"PASSED"},{"caseNumber":"215568","date":"2009-09-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"215568","date":"2009-11-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"215568","date":"2010-01-13","type":"CI INSP","status":"CLOSED"},{"caseNumber":"215568","date":"2010-01-13","type":"CI INSP","status":"FAILED"},{"caseNumber":"215568","date":"2010-03-04","type":"PRECOURT","status":"FAILED"},{"caseNumber":"215568","date":"2010-03-04","type":"PRECOURT","status":"FAILED"},{"caseNumber":"215568","date":"2010-06-21","type":"PRECOURT","status":"PASSED"},{"caseNumber":"240344","date":"2010-06-21","type":"CI INSP","status":"FAILED"},{"caseNumber":"240344","date":"2010-12-29","type":"CI INSP","status":"PASSED"},{"caseNumber":"240344","date":"2011-01-19","type":"CI INSP","status":"PASSED"},{"caseNumber":"517275","date":"2016-01-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"517272","date":"2016-01-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"517275","date":"2016-02-26","type":"CI INSP","status":"FAILED"},{"caseNumber":"522743","date":"2016-02-26","type":"CI INSP","status":"FAILED"},{"caseNumber":"517275","date":"2016-03-22","type":"CI INSP","status":"PASSED"},{"caseNumber":"517272","date":"2016-04-27","type":"CI INSP","status":"PASSED"},{"caseNumber":"522743","date":"2016-04-27","type":"CI INSP","status":"FAILED"},{"caseNumber":"522743","date":"2016-07-27","type":"CI INSP","status":"CLOSED"},{"caseNumber":"522743","date":"2016-11-04","type":"PRECOURT","status":"PASSED"}],"inspYears":[{"y":2006,"fails":1,"passes":0},{"y":2009,"fails":2,"passes":1},{"y":2010,"fails":4,"passes":2},{"y":2011,"fails":0,"passes":1},{"y":2016,"fails":5,"passes":3}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.92592662600621,"lng":-75.14974530301235,"geom":{"type":"Polygon","coordinates":[[[-75.149582719,39.925860586],[-75.149600479,39.925814434],[-75.149944228,39.925894913],[-75.149890002,39.926039344],[-75.149545542,39.925958316],[-75.149582719,39.925860586]]]},"liDistrict":"SOUTH","certifications":[{"number":"BC-2022-001818","type":"Fire Alarm Certification","inspectionDate":"2022-02-10","result":"Certified","expirationDate":"2023-02-10","buildingId":"1526117"},{"number":"BC-2025-010844","type":"Sprinkler Certification","inspectionDate":"2025-04-01","result":"Certified","expirationDate":"2026-04-01","buildingId":"1526117"},{"number":"BC-2026-006968","type":"Fire Alarm Certification","inspectionDate":"2026-02-18","result":"Certified","expirationDate":"2027-02-18","buildingId":"1526117"},{"number":"BC-2026-011828","type":"Sprinkler Certification","inspectionDate":"2026-03-23","result":"Certified","expirationDate":"2027-03-23","buildingId":"1526117"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19148","beds":null,"baths":null,"stories":3,"lotArea":5400,"zoning":"CMX2","grade":"C+","basement":null,"heater":null,"centralAir":null,"extCond":"2","intCond":"2","garage":null,"homestead":false,"mail":"243 GREENWICH ST, PHILADELPHIA PA, 19147","mailOut":false,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF A THIRD FLOOR ADDITION WITH ROOF DECK AND PILOT HOUSE( NTE 90 SF AREA) , FOR A VACANT TWO(2) COMMERCIAL SPACE AT FIRST FLOOR IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING ( TWELVE(12) DWELLING UNITS FROM","status":"OPEN","outcome":"Granted","date":"2017-02-08","number":"29651","relatedPermit":"739946"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":1,"abated":true,"assessmentExemption":true,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":702000,"taxable":702000,"land":135000,"improvement":567000,"taxableLand":135000,"taxableImprovement":567000,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":702000,"taxable":702000,"land":135000,"improvement":567000,"taxableLand":135000,"taxableImprovement":567000,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":823600,"taxable":823600,"land":164679,"improvement":658921,"taxableLand":164679,"taxableImprovement":658921,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":2650000,"taxable":647400,"land":265000,"improvement":2385000,"taxableLand":265000,"taxableImprovement":382400,"exemptLand":0,"exemptImprovement":2002600},{"y":2020,"v":2663200,"taxable":650520,"land":266320,"improvement":2396880,"taxableLand":266320,"taxableImprovement":384200,"exemptLand":0,"exemptImprovement":2012680},{"y":2021,"v":2663200,"taxable":650520,"land":266320,"improvement":2396880,"taxableLand":266320,"taxableImprovement":384200,"exemptLand":0,"exemptImprovement":2012680},{"y":2022,"v":2663200,"taxable":650520,"land":266320,"improvement":2396880,"taxableLand":266320,"taxableImprovement":384200,"exemptLand":0,"exemptImprovement":2012680},{"y":2023,"v":2663200,"taxable":649821,"land":266320,"improvement":2396880,"taxableLand":266320,"taxableImprovement":383501,"exemptLand":0,"exemptImprovement":2013379},{"y":2024,"v":2663200,"taxable":649821,"land":266320,"improvement":2396880,"taxableLand":266320,"taxableImprovement":383501,"exemptLand":0,"exemptImprovement":2013379},{"y":2025,"v":2663200,"taxable":649821,"land":266320,"improvement":2396880,"taxableLand":266320,"taxableImprovement":383501,"exemptLand":0,"exemptImprovement":2013379},{"y":2026,"v":2663200,"taxable":649821,"land":266320,"improvement":2396880,"taxableLand":266320,"taxableImprovement":383501,"exemptLand":0,"exemptImprovement":2013379},{"y":2027,"v":2506500,"taxable":611544,"land":250600,"improvement":2255900,"taxableLand":250600,"taxableImprovement":360944,"exemptLand":0,"exemptImprovement":1894956}],"taxNow":9096,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"270943","date":"2010-04-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REPLACE 2 PULL STATIONS & 3 SMOKE DETECTORS WITH SAME MAKE & MODEL."},{"number":"426852","date":"2012-09-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"CHANGE OUT 2-200AMP PANELS EXISTING WIRING CHANGE OUT 25-2X4 FLUORESCENT FIXTURES IN DROP CEILING CHANGE OUT 15 WALL LIGHTS EXISTING WIRE MC CABLE PER 2008 NEC (COMMERCIAL)"},{"number":"711574","date":"2016-08-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"2ND FL FURNISH AND INSTALL 8 NEW FLUORESCENT STRIP FIXTURES, 3 NEW EXIT SIGNS REFEED PANEL WITH NEW 100AMP SERVICE CABLE AS PER 2008 NEC (SOUTH DISTRICT)"},{"number":"739946","date":"2017-03-01","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2017-03-01","scope":"FOR THE ERECTION OF A THIRD FLOOR ADDITION WITH ROOF DECK AND PILOT HOUSE( NTE 90 SF AREA) , FOR A VACANT TWO(2) COMMERCIAL SPACE AT FIRST FLOOR IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING ( TWELVE(12) DWELLING UNITS FROM SECOND FLOOR THROUGH THIRD FLOORS. NO SIGN ON THIS APPLICATION. SIZE AND LOCATION AS SHOWN IN THE APPLICATION."},{"number":"768667","date":"2017-03-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-02-22","scope":"SEAL LATERAL PA20170810629 (COMMERICAL)SELF CERTIFICATION'S ARE NO LONGER PERMITTED\",\"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\""},{"number":"780592","date":"2017-05-03","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-09-10","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"772531","date":"2017-05-30","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2018-09-12","scope":"NO REMOVAL OF MORE THAN 2/3 OF FRAMING MEMBERS. FOR THE ERECTION OF A 3RD FLOOR ADDITION, ROOF DECK ACCESS STRUCTURE, ELEVATOR, OPEN EXIT ACCESS STAIRWAY FROM ROOF DECK TO 3RD FLOOR, COMPLETE CHANGE IN USE AND OCCUPANCY CLASSIFICATION WITH LEVEL III INTERIOR ALTERATION, AND ALL OTHER WORK AS PER APPROVED PLANS. FOR A VACANT TWO(2) COMMERCIAL SPACES AT FIRST FLOOR IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING ( TWELVE(12) DWELLING UNITS - TYPE B UNITS - FROM 1ST FLOOR THROUGH THIRD FLOORS. *ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK* ENTIRE BUILDNIG TO BE SPRINKLERED PER NFPA 13* SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK."},{"number":"793310","date":"2017-09-14","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-05-09","scope":"AMENDMENT TO APPLICATION #772531 AS PER APPROVED PLANS AND PER ATTACHED LETTER."},{"number":"809410","date":"2017-09-14","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-09-10","scope":"AMENDMENT TO PERMIT #772531 TO INCREASE THE FIRE RESISTANCE RATING OF THE HORIZONTAL AND VERTICAL WALL AND FLOOR ASSEMBLIES BETWEEN THE RESIDENTIAL AND COMMERCIAL SPACE TO TWO (2) HOUR FIRE RESISTANCE RATED CONSTRUCTION. THIS PERMIT TO ALSO DOCUMENT THAT THE BUILDING IS PERMITTED TO BE SPRINKLERED PER NFPA 13 AND NFPA 13R."},{"number":"803515","date":"2017-09-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-09-10","scope":"INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 & 13R THROUGHOUT THE BUILDING TO INCLUDE 4\" MAIN FIRE SERVICE LINE AND 2-1/2\" WILKINS 350XL BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"829503","date":"2017-11-03","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-04-23","scope":"EZ PLUMBING - REPLACE CURB TRAP & FAI AND 2\" WATER SERVICE AND 2\" BACKFLOW PREVENTER AS PER THE 2004 PHILADELPHIA PLUMBING CODE. OPENING PMT #201711982."},{"number":"828072","date":"2018-04-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-09-10","scope":"INSTALL NEW 1000AMP 120/208V ELECTRIC SERVICE 12 APT SERVICES 2 COMMERCIAL SERVICES AND 1 HOUSE SERVICE AS PER 2008 NEC INSTALL WIRING AND DEVICES FOR LIGHTING POWER COMMUNICATIONS AND HVAC AND FIRE ALARM"},{"number":"852367","date":"2018-04-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-09-10","scope":"96 PLUMBING FIXTURES WITH PIPING FOR THE ADDITION OF 12 DWELLING UNITS AND 3 COMMERCIAL SPACES -THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"866901","date":"2018-05-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-09-10","scope":"INSTALLATION OF (13) MINI SPLIT SYSTEMS AND (2) GAS FURNACES WITH 4 TON AIR CONDITION UNIT WITH ASSOCIATED DUCT WORK AS PER PLANS."}],"storyTag":"Improved","storyDelta":null,"timeline":[{"y":2017,"k":"permit","w":"Zoning/use"},{"y":2017,"k":"permit","w":"Plumbing"},{"y":2017,"k":"sale","p":550000},{"y":2017,"k":"permit","w":"Demolition"},{"y":2017,"k":"permit","w":"Addition"},{"y":2017,"k":"permit","w":"Administrative"},{"y":2017,"k":"permit","w":"Administrative"},{"y":2017,"k":"permit","w":"Suppression"},{"y":2017,"k":"permit","w":"Plumbing"},{"y":2018,"k":"permit","w":"Electrical"},{"y":2018,"k":"permit","w":"Plumbing"},{"y":2018,"k":"permit","w":"Mechanical"}],"rented":true,"licenses":[{"number":"208795","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"OREGON NEW YEARS ASSOC INC","legalName":"OREGON NEW YEARS ASSOC INC","address":"1728-32 S 2ND ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2004-04-16","latestIssueDate":"2015-05-03","expirationDate":"2016-04-30","inactiveDate":"2016-06-29"},{"number":"789968","type":"Rental","status":"Active","businessName":"1728 S. 2nd Street Partners LLC","legalName":"1728 S. 2nd Street Partners LLC","address":"1728-32 S 2ND ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":12,"issuedDate":"2018-09-25","latestIssueDate":"2025-09-02","expirationDate":"2026-09-24","inactiveDate":null}],"licenseActivity":[{"number":"789968","type":"Rental","businessName":"1728 S. 2nd Street Partners LLC","legalName":"1728 S. 2nd Street Partners LLC","issuedDate":"2018-09-25","latestIssueDate":"2025-09-02","closureDate":null,"expirationDate":"2026-09-24","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"208795","type":"Food Preparing and Serving (30+ SEATS)","businessName":"OREGON NEW YEARS ASSOC INC","legalName":"OREGON NEW YEARS ASSOC INC","issuedDate":"2004-04-16","latestIssueDate":"2015-05-03","closureDate":"2016-06-29","expirationDate":"2016-04-30","inactiveDate":"2016-06-29","status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-24","units":12,"signals":[],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Appeal #29651: OPEN · Granted; related permit 739946. Use permit #739946: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"rental-license","level":"verify","title":"A rental license does not transfer with the deed","finding":"1 active Rental License record matched.","why":"If dwelling space is rented, the buyer must obtain a new annual Rental License; the seller’s license is not transferable. New applications require proof of ownership and legal occupancy, tax compliance, no open L&I violations, and lead compliance where applicable.","action":"Plan the buyer’s replacement license before settlement.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"lead","level":"verify","title":"Lead compliance is a separate record","finding":"OPA records a 1915 build year; BlockReport does not receive the Health Department’s unit-level lead certificate file.","why":"Philadelphia requires covered pre-March-1978 rentals to be certified lead-safe or lead-free for a new or renewed lease and for a new or renewed Rental License. A certificate is unit-specific; a renovation does not by itself create an exemption.","action":"Request the current lead certificate or City exemption for every dwelling unit.","url":"https://www.phila.gov/documents/lead-and-healthy-homes-resources-for-landlords/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"12 failed, 7 passed, and 2 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Nov 4, 2016.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Preparing and Serving (30+ SEATS) #208795: Inactive since Jun 29, 2016","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"abatement","level":"verify","title":"A reduced taxable assessment is not a verified abatement","finding":"OPA’s numeric assessment fields show a reduced taxable assessment; BlockReport has no official program determination for this parcel.","why":"The numeric treatment can reflect an improvement abatement or another exemption. It does not identify the ordinance, approval, start or end date, or continuation requirements after a transfer. Once OPA verifies a specific active abatement, many common programs attach the benefit to the property for the remaining term rather than ending automatically at sale, but some require a new-owner filing and continued qualifying use or tax compliance.","action":"Obtain the OPA exemption/abatement determination and history, then underwrite the buyer’s bill from the verified program terms.","url":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/get-a-property-tax-abatement/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as multi-family. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 25 historical violations across 5 cases.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"building-certifications","level":"clear","title":"Filed system certifications are current in this dataset","finding":"Fire Alarm Certification: Certified through Feb 18, 2027; Sprinkler Certification: Certified through Mar 23, 2027","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Confirm the certificate covers every applicable system and remains accepted by L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}