{"asOf":"2026-07-27T23:32:01.482Z","block":"1100-1199 CECIL B MOORE AVE","blockUrl":"https://philadelphia.blockreport.homes/block/1100-1199-cecil-b-moore-ave","address":"1101-37 CECIL B MOORE AVE","parcelNumber":"881147220","source":"https://property.phila.gov/?p=881147220","ownerType":"investor","kind":"apartments","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"CE0","buildingCodeNew":"613","buildingClass":"APTS DORMITORY MASONRY","buildingClassNew":"COLLEGES & UNIVERSITY","useLabel":"Apartment building","owner":"SOUTHMOORE OWNER LLC","coOwner":null,"marketValue":99616800,"landAssessment":9961600,"improvementAssessment":89655200,"livableArea":461286,"yearBuilt":2018,"lastSale":{"price":10,"date":"2017-09-18T04:00:00Z"},"openViolations":0,"violations":[{"number":"VI-2025-006103","date":"2025-02-04","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2025-04-21","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2025-006104","date":"2025-02-04","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-06-12","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2026-004345","date":"2026-01-22","code":"9-3402(2)","title":"BENCHMARKING LATE","status":"CLOSED","resolutionDate":"2026-03-17","resolution":"CLOSED - ADMINISTRATIVELY"}],"violationCases":[{"number":"CF-2025-007580","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2025-02-04","completedDate":"2025-09-08","violations":[{"number":"VI-2025-006103","date":"2025-02-04","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2025-04-21","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2025-006104","date":"2025-02-04","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2025-06-12","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2026-006844","type":"NOTICE OF VIOLATION","priority":"ADMINISTRATIVE NOTICE OF VIOLATION","responsibility":"OOS INVESTIGATOR","status":"COMPLIED, BALANCE DUE","createdDate":"2026-01-22","completedDate":null,"violations":[{"number":"VI-2026-004345","date":"2026-01-22","code":"9-3402(2)","title":"BENCHMARKING LATE","status":"CLOSED","resolutionDate":"2026-03-17","resolution":"CLOSED - ADMINISTRATIVELY"}]}],"violYears":[{"y":2025,"n":2,"worst":null},{"y":2026,"n":1,"worst":null}],"investigations":[{"caseNumber":"CF-2025-007580","date":"2025-02-04","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-007580","date":"2025-03-17","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-007580","date":"2025-04-21","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-007580","date":"2025-06-12","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-007580","date":"2025-09-08","type":null,"status":"PASSED"},{"caseNumber":"CF-2026-006844","date":"2026-01-22","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-006844","date":"2026-03-17","type":null,"status":"PASSED"}],"inspYears":[{"y":2025,"fails":4,"passes":1},{"y":2026,"fails":1,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.978578179461636,"lng":-75.15326124428412,"geom":{"type":"Polygon","coordinates":[[[-75.152478752,39.978881976],[-75.152650118,39.978094821],[-75.154043731,39.978274378],[-75.153872379,39.979061534],[-75.152478752,39.978881976]]]},"liDistrict":"CENTRAL EAST","certifications":[{"number":"BC-2025-000480","type":"Special Hazards Certification","inspectionDate":"2024-12-02","result":"Certified","expirationDate":"2025-12-02","buildingId":"3000025"},{"number":"BC-2025-000665","type":"Special Hazards Certification","inspectionDate":"2024-12-31","result":"Certified","expirationDate":"2025-12-31","buildingId":"3000025"},{"number":"BC-2025-015324","type":"Sprinkler Certification","inspectionDate":"2025-01-16","result":"Certified","expirationDate":"2026-01-16","buildingId":"3000025"},{"number":"BC-2025-004910","type":"Sprinkler Certification","inspectionDate":"2025-01-16","result":"Deficient","expirationDate":null,"buildingId":"3000025"},{"number":"BC-2026-000009","type":"Special Hazards Certification","inspectionDate":"2025-12-31","result":"Certified","expirationDate":"2026-12-31","buildingId":"3000025"},{"number":"BC-2026-018576","type":"Special Hazards Certification","inspectionDate":"2026-06-30","result":"Certified","expirationDate":"2027-06-30","buildingId":"3000025"},{"number":"BC-2026-018605","type":"Special Hazards Certification","inspectionDate":"2026-06-30","result":"Certified","expirationDate":"2027-06-30","buildingId":"3000025"},{"number":"BC-2026-018640","type":"Fire Alarm Certification","inspectionDate":"2026-06-30","result":"Certified","expirationDate":"2027-06-30","buildingId":"3000025"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19122","beds":null,"baths":null,"stories":18,"lotArea":115133,"zoning":"CMX4","grade":"C+","basement":null,"heater":null,"centralAir":null,"extCond":"1","intCond":"1","garage":null,"homestead":false,"mail":"630 SENTRY PKWY, BLUE BELL PA, 19422","mailOut":true,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR THE PARTIAL DEMOLITION OF PREVIOUSLY APPROVED ROOF FROM FIRST FLOOR (1ST)THROUGH EIGHTEEN(18) FLOORS ( CREATES EXISTING ENCLOSED LOADING SPACES INTO A OPEN AIR LOADING SPACES)  ON THE SAME LOT THREE (3) VACANT COMMERCIAL SPACES A","status":"OPEN","outcome":"Granted","date":"2018-06-13","number":"33736","relatedPermit":"866559"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":2,"abated":true,"assessmentExemption":true,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":961100,"taxable":961100,"land":961100,"improvement":0,"taxableLand":961100,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":961100,"taxable":961100,"land":961100,"improvement":0,"taxableLand":961100,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":961100,"taxable":961100,"land":961100,"improvement":0,"taxableLand":961100,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":23380000,"taxable":9021440,"land":8757140,"improvement":14622860,"taxableLand":8757140,"taxableImprovement":264300,"exemptLand":0,"exemptImprovement":14358560},{"y":2020,"v":87571400,"taxable":8757140,"land":8757140,"improvement":78814260,"taxableLand":8757140,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":78814260},{"y":2021,"v":87571400,"taxable":8757140,"land":8757140,"improvement":78814260,"taxableLand":8757140,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":78814260},{"y":2022,"v":87571400,"taxable":8757140,"land":8757140,"improvement":78814260,"taxableLand":8757140,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":78814260},{"y":2023,"v":87571400,"taxable":8757140,"land":8757140,"improvement":78814260,"taxableLand":8757140,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":78814260},{"y":2024,"v":87571400,"taxable":8757140,"land":8757140,"improvement":78814260,"taxableLand":8757140,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":78814260},{"y":2025,"v":87571400,"taxable":8757140,"land":8757140,"improvement":78814260,"taxableLand":8757140,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":78814260},{"y":2026,"v":87571400,"taxable":8757140,"land":8757140,"improvement":78814260,"taxableLand":8757140,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":78814260},{"y":2027,"v":99616800,"taxable":9961600,"land":9961600,"improvement":89655200,"taxableLand":9961600,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":89655200}],"taxNow":122582,"familyHeld":false,"lastTransferNominal":true,"permits":[{"number":"165657","date":"2008-07-21","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2008-07-21","scope":"USE PERMIT FOR CHARTERED SCHOOL, INCLUDING CLASSROOMS, ADMINISTRATIVE OFFICES AND CAFETERIA SERVING PREPARED AND PREPACKAGED FOODS"},{"number":"310991","date":"2010-11-18","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2012-01-21","scope":"COMPLETE DEMOLITION OF PROPERTY"},{"number":"310988","date":"2010-11-18","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2010-11-18","scope":"COMPLETE DEMOLITION OF VACANT (WANAMAKER) SCHOOL."},{"number":"319215","date":"2011-01-26","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2011-01-26","scope":"RELOCATION OF LOT LINES"},{"number":"321271","date":"2011-02-17","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2011-02-17","scope":"UNITY OF USE, ERECT A (16) STORT STRUCTURE MAX. HT. (188.7') MIXED USE, NO SIGNS."},{"number":"390744","date":"2012-03-12","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2012-03-12","scope":"EXTINGUISH PRIOR UNITY OF USE. RELOCATE LOT LINES TO CREATE (2) LOTS FROM (2) LOT. CONSTRUCT (1) STORY AND (14) STORY PLUS MECHANICAL PENTHOUSE. USES TO BE FLOOR 1 LOBBY, STUDENT ROOM, OFFICE, MAILROOM, FINESS ROOM AND ENCLOSED LOADING AREA, RESTAURANT(EAT-IN ONLY) AND USES PERMITTED IN C-4, FLOORS 2-14 (238) DWELLING UNITS EACH HAVING (4) PERSONS UNRELATED BY BLOOD OR MARRIAGE. FLOOR 3 ACCESSORY LOUNGE, CONFERENCE ROOM."},{"number":"395922","date":"2012-03-29","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2012-03-29","scope":"FOR A VACANT LOT."},{"number":"430924","date":"2012-10-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-08-01","scope":"TO INSTALL 2 12\" LATERALS AND TRAPS 24\" STORM LINE, STORM DET BASIN (OFFICE RETAIL) PA1 CALL# 2012 2430239"},{"number":"22021","date":"2012-11-15","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2012-11-16","scope":"GOLDENBERG GROUP EVENT-GROUND BREAKING"},{"number":"732400","date":"2017-03-15","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2017-03-15","scope":"UNITY OF USE OF THE LOTS, FOR THE PURPOSES OF ZONING, WHEREAS THE UNITY OF USE WILL BOUND BY EASEMENTS,AGREEMENTS, AND CONVENANTS CLEARLY LIMITING PRESENT AND FUTURE OWNERS OF THE LOTS/PARCELS TO A UNITY OF USE, WHICH WILL BE RECORDED. 2) CONSTRUCT ONE DETACHED BUILDIGN 8- AND 17-STORY BUILDING, WITH BELOW GRADE PARKING GARAGE, WITH EXPANSION RECONFIGURATION OF EXISTING PARKING LOT TO DECREASE THE NUMBER OF PARKIN GSPACES FROM 80 TO 71. 3). WITH USES AS NOTED ABOVE. 4). WITH RELATED BUILDING AND SITE IMPROVEMENTS, ALL AS PER SUBMITTED PLANS PREPARED BY BOHLER ENGINEERING, DATED 10/16/2016. 5). WITHOUT PREJUDICE TO, OR ABANDONMENT OF ALL PRIOR PERMITS AND APPROVALS. 6). CONDITIOONAL ZONING PERMIT ISSUANCE REQUESTED."},{"number":"782087","date":"2017-07-14","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2017-07-14","scope":"FOR THE ERECTION OF A DETACHED STRUCTURE ( MAXIMUM 220.5 FT HIGH). SIZE AND LOCATION ON THE APPLICATION. FOR THREE (3) VACANT COMMERCIAL SPACES AT FIRST FLOOR ( USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING THREE-HUNDRED AND SIXTY-EIGHT ( 368) DWELLING UNITS FROM 2ND FLOOR THROUGH ABOVE FLOORS, AND ACCESSORY OFF STREET SURFACE PARKING NINETY-FOUR (94) SPACES INCLUDING WITH 21 COMPACT SPACES, FOUR (4) ADA SPACES, 6 ELECTRIC CARS SPACES, 7 CAR SHARE SPACES, AND FIVE (5) RESERVOIR SPACES, AND TWO (2) LOADING SPACES AND ONE HUNDRED THIRTY (130) CLASS 1A BICYCLE SPACES ON AN ACCESSIBLE ROUTE. SIZE AND LOCATION ON THE APPLICATION"},{"number":"800639","date":"2017-09-12","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2019-07-30","scope":"FOR THE ERECTION OF A 18 STORY STRUCTURE FOR USE AS 368 DWELLING UNITS WITH ACCESSORY FACILITES FROM THE SECOND FLOOR AND ABOVE, INDOOR FITNESS AREA ACCESSED BY RESIDENTIAL OCCUPANTS ONLY (SEPARATE PERMIT REQUIRED FOR OUTDOOR FITNESS AREA- LEVEL 3), WITH VACANT COMMERICAL SPACES ON THE FIRST FLOOR LEVEL (SEPARATE USE PERMIT AND CERTIFICATE OF OCCUPANCY REQUIRED PRIOR TO OCCUPANCY.) LOT TO ALSO CONTAIN 94 ACCESSORY OFF STREET PARKING SPACES. BUILDING TO BE FULLY SPRINKLERED WITH STANDPIPES IN EACH EXIT STAIRWAYS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 56 FEET OF THE BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE 2009 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK."},{"number":"823284","date":"2017-11-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-07-30","scope":"NEW CONSTRUCTION: EXTERIOR PLUMBING; 18 STORY STRUCTURE FOR USE AS 368 DWELLING UNITS; SITEWORK;(2)15\" AND (2)12\" HOUSE DRAINS WITH TRAPS/FAI; PA20172680717 \"SELF-CERTIFICATION'S ARE NO LONGER PERMITTED\" - \"ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION\"- THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004"},{"number":"828384","date":"2017-11-15","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2017-11-15","scope":"FOR THE ERECTION OF ROOF DECK AT THIRD FLOORS (RESIDENTIAL USE ONLY) IN THE SAME BUILDING EXISTING DETACHED STRUCTURE(MAXIMUM 220.5 FT HIGH) ( SEE APP# 782087 FOR THE PERMIT) FOR AN EXISTING THREE (3) VACANT COMMERCIAL SPACES AT FIRST FLOOR ( USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING THREE-HUNDRED AND SIXTY-EIGHT (368) DWELLING UNITS FROM 2ND FLOOR THROUGH ABOVE FLOORS, AND ACCESSORY OFF STREET SURFACE PARKING NINETY-FOUR (94) SPACES INCLUDING WITH 21 COMPACT SPACES, FOUR (4) ADA SPACES, 6 ELECTRIC CARS SPACES, 7 CAR SHARE SPACES, AND FIVE (5) RESERVOIR SPACES, AND TWO (2) LOADING SPACES AND ONE HUNDRED THIRTY (130) CLASS 1A BICYCLE SPACES ON AN ACCESSIBLE ROUTE.(SIZE AND LOCATION AS SHOWN N THE APPLICATION."},{"number":"833056","date":"2017-12-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-07","scope":"NEW PECO SVC, SWITCHGEAR, PANELBOARDS, LOAD CENTERS, TRANSFORMERS, LIT FIXTURES, SWITCHES, RCTS, PWR TO HVAC, SECURITY EQUIPMENT&WIRING, RACEWAYS FOR TELECOM SYSTEM, GROUNDING, LIGHTING PROTECTION, FIRE ALARM EQUIPMENT&WIRING, AREA OF RESCUE EQUIPMENT&WIRING, FIRE PHONES&SITE LIGHTING/PWR. JOBSITE TEMP LIGHTING&PWR THROUGHOUT. AS PER 2008 NEC."},{"number":"831820","date":"2017-12-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-07-30","scope":"NEW 18 STORY BUILDING WITH 2659 PLUMBING WITH STORM, SANITARY AND DOMESTIC WATER PIPING. - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"840256","date":"2018-01-09","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-02-12","scope":"FOR THE AMENDMENT OF BUILDING PERMIT 800639, ISSUED FOR FOUNDATION AND NEW CONSTRUCTION OF A HIGH RISE MULTI-FAMILY BUILDING WITH COMMERCIAL SPACES AND ACCESSORY PARKING. PERMIT TO BE APPROVED FOR THE ASSEMBLY AND DISASSEMBLY OF ASSOCIATED TOWER CRANE TO BE LOCATED ENTIRELY WITHIN PROPERTY LINES, NO ENCROACHMENT OF PUBLIC FOOTWAYS PROPOSED AS PER DESIGN ENGINEERED PLANS AND SPECIFICATIONS. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK."},{"number":"836464","date":"2018-01-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-30","scope":"INSTALLATION OF NEW HVAC SYSTEM FOR A MIXED USE RESIDENTIAL/COMMERCIAL BUILDING TO INCLUDE INSTALLATION OF HEAT PUMPS, COOLING TOWER, HYDRONIC PUMPS, BOILERS AND HEAT EXCHAGES WITH ALL ASSOCIATED PIPE, DUCTWORK, INSULATION, AND TEMPERATURE CONTROLS AS PER APPROVED PLANS."},{"number":"868540","date":"2018-05-31","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-07-30","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 FOR A HIGH RISE SERVICED BY TWO SEPARATE 8\" FIRE SERVICE LINES WITH BACK FLOW PREVENTER ASSEMBLIES AND A FIRE PUMP. SEPARATE FIRE SUPPRESSION SYSTEM TO BE PROVIDED IN TRASH CHUTE, TO BE COMPLETED BY MANUFACTURER. UNDERGOUND FIRE SERVICE (CONTROL VALVES) PREVIOUSLY APPROVED BY PWD. FIRE SUPPRESSION SYSTEM TO ALSO INLCUDE THE INSTALLATION OF STANDPIPES IN EACH EXIT STAIRWAY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13, NFPA 14 AND NFPA 20 STANDARDS."},{"number":"866559","date":"2018-07-10","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2018-07-10","scope":"FOR THE PARTIAL DEMOLITION OF PREVIOUSLY APPROVED ROOF FROM FIRST FLOOR (1ST)THROUGH EIGHTEEN(18) FLOORS ON THE SAME LOT THREE (3) VACANT COMMERCIAL SPACES AT FIRST FLOOR ( USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING THREE-HUNDRED AND SIXTY-EIGHT (368) DWELLING UNITS FROM 2ND FLOOR THROUGH EIGHTEEN(18TH)FLOORS, AND ACCESSORY OFF STREET SURFACE PARKING SPACES (NINETY-FOUR (94) SPACES INCLUDING WITH 21 COMPACT SPACES, FOUR (4) ADA SPACES, 6 ELECTRIC CARS SPACES, 7 CAR SHARE SPACES, AND FIVE (5) RESERVOIR SPACES, AND TWO (2) LOADING SPACES AND ONE HUNDRED THIRTY (130) CLASS 1A BICYCLE SPACES ON AN ACCESSIBLE ROUTE AS PREVIOUSLY APPROVED STRUCTURE A PER APPLICATION# 828384 AND 782087 AS PREVIOUSLY APPROVED.NO SIGN ON THIS APPLICATION."},{"number":"938535","date":"2019-01-03","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2019-01-03","scope":"CREATE 3 COMMERCIAL/RETAIL SPACES FROM 1 APPROVED SPACE. FOR USES STATED ABOVE. NO OTHER CHANGES IN USES: NO CHANGES TO BUILDING HEIGHT, FOOTPRINT, OR AREA ALL AS PER SUBMITTED PLANS PREPARED BY BOHLER ENGINEERING DATED 10/26/18, AS LAST REVISED 12/20/18. WITHOUT PREJUDICE TO, OR ABANDONMENT OF , ALL PRIOR PERMITS AND APPROVAL."},{"number":"949119","date":"2019-03-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-07-26","scope":"FOR INTERIOR/EXTERIOR ALTERATIONS FOR THE FITOUT OF A TENANT SPACE FOR A MERCANTILE USE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"964521","date":"2019-04-05","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-07-26","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"964836","date":"2019-04-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-07-26","scope":"ALTERATIONS FOR THE FITOUT OF A TENANT SPACE FOR A MERCANTILE USE.;1 R/X SINK, 2 WATER CLOSETS, 3 LAV SINKS, 1 WATER COOLER, 1 WALL DRAIN STAND PIPE, 1 BREAKROOM SINK, 1 MOP SINK."},{"number":"964531","date":"2019-05-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-26","scope":"TIE INTO EXISTING SERVICE-INSTALL NEW PANELS, FIXTURES, RECEPTACLES, SWITCHES. WIRE HVAC UNITS AS PER 2017 NEC (EAST DIST)"},{"number":"972091","date":"2019-05-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-26","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSER AND APPLIANCES WITH ASSOCIATED DUCTWORK IN AN EXISTING BUSINESS OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTIANED FOR ALL OTHER WORK."},{"number":"980413","date":"2019-05-29","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2019-06-06","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY FOR EAST TOWER FLOORS 1 THRU 19(EXCLUDING INNOVATION AND SKY LOUNGE.OCCUPY WEST TOWER FLOORS 1 THRU 12 (EXCLUDING RETAIL AND AMENITY AREAS)"},{"number":"980568","date":"2019-05-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-02","scope":"21 CEILING SPEAKERS,3 VC'S,3 HORNS,1 AMP AND 1 MUSIC PLAYER PER 2017 NEC (COMMERCIAL)"},{"number":"974950","date":"2019-06-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-30","scope":"INSTALLATION OF NEW FIRE PLACE AS PER PLAN AND MANUFACTURES SPECIFICATION. ** WORK TO INCLUDE AMENDMENT TO DUCTWORK INSTALLED UNDER PERMIT # 836464. SEE PLAN FOR REVISION.**"},{"number":"972534","date":"2019-06-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-17","scope":"INSTALL 110-CATEGORY 5E CABLES FOR VOICE, DATA, & POINT OF SALE LOCATION ALL CABLING WILL BE SUPPORTED BY J-HOOKS & HOME RUN BACK TO COMMUNICATION EQIPMENT CABINET IN ELECTRICAL ROOM AS PER NEC 2008 NORTH CENTRAL DISTRICT"},{"number":"981838","date":"2019-06-24","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-06-24","scope":"FOR THE ERECTION OF TWO(2) FLATWALL SIGNS ( ONE(1) EACH SOUTH AND EAST ELEVATION OF THE BUILDING) AND FOR THE ERECTION OF ONE(1) FLATWALL SIGN ( EAST ELEVATION)ACCESSORY TO EXISTING SUNDRIES PHARMACEUTICAL AND CONVINENCE SALES AT SPACE# 1 ON THE SAME LOT SPACE #2 VACANT(USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY), SPACE #3 FOR FINANCIAL SERVICES IN AN EXISTING STRUCTURE WITH OTHER PREVIOUSLY APPROVED USES.SIZE AND LOCATION AS SHOWN IN THE APPLICATION."},{"number":"988185","date":"2019-07-12","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2019-07-23","scope":"ALL DIMENSIONS AS PER PLANS. INSTALL TWO SETS 74.43 SQ FT ILLUM LETTERS, ONE EACH ON SOUTH AND WEST ELEVATION (SIGN TYPE 1A). INSTALL ONE SET 52.18 SQ FT ILLUM LETTERS ON EAST ELEVATION (SIGN TYPE 2A) CONNECT ALL TO EXISTING ELECTRIC.(DETAILS AS PER PLAN)."},{"number":"983292","date":"2019-07-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-08","scope":"INSTALL FIRE ALARM AS PER NFPA 72 (NORTH DIST)"},{"number":"991513","date":"2019-08-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-11-26","scope":"FOR LEVEL II INTERIOR/EXTERIOR ALTERATIONS OF FITOUT OF A TENANT SPACE FOR A FINANCIAL SERVICES IN SPACE#3. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL OTHER MEPS WORK."},{"number":"1000098","date":"2019-08-09","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-11-25","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSER AND APPLIANCES WITH ASSOCIATED DUCTWORK IN SPACE #3. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTIANED FOR ALL OTHER WORK."},{"number":"993217","date":"2019-08-16","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-08-16","scope":"FOR THE INSTALLATION OF ONE (1) ACCESSORY, DOUBLE-SIDED, STATICALLY ILLUMINATED PROJECTING SIGN (SIGN \"3A\" ON PLANS) ON THE FACADE FACING CECIL B MOORE AVENUE OF AN UNDER-CONSTRUCTION HIGH-RISE BUILDING, SIZE AND LOCATION AS SHOWN ON PLAN/APPLICATION. SIGN ACCESSORY TO PREVIOUSLY APPROVED USE OF SUNDRIES, PHARMACEUTICALS, AND CONVENIENCE SALES WITHIN SPACE #1 UNDER PREVIOUSLY ISSUED USE PERMIT AP#938535."},{"number":"993220","date":"2019-08-16","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2020-10-08","scope":"FOR THE INSTALLATION OF ONE (1) ACCESSORY, DOUBLE-SIDED, STATICALLY ILLUMINATED WALL SIGN (SIGN \"3A\" ON PLANS) ON THE CECIL B MOORE FACADE OF AN UNDER-CONSTRUCTION HIGH-RISE BUILDING, AND FOR A RETAIL PHARMACY TENANT WITHIN SPACE #1 ON THE GROUND FLOOR, AS PER PLANS; SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK; SEE AP#993217 FOR ZONING/USE APPROVAL."},{"number":"1005011","date":"2019-08-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-11-25","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"1003418","date":"2019-08-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-11-25","scope":"FITOUT FOR FINANCIAL SERVICES OFFICE FIXTURES INCLUDE 2 WATER CLOSETS 2LAVS 1DRINKING FOUNTAIN 1 KITCHEN SINK 2FLOOR DRAINS 1MOP SINK 1HOT WATER HEATER"},{"number":"1003255","date":"2019-09-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-11-26","scope":"NEW WIRE THROUGHOUT: OUTLETS, SWITCHES, AND LIGHTING. ADD PANELS AS PER PLAMS AND 2008 NEC CODE INSTALL EMERGENCY EXITS AND REMOTE HEADS. GROUNDING. DATA, AND SECURITY AS PER PLANS AND 2008 NEC CODE.***NO FIRE ALARM ON THIS PERMIT*** (NORTH DIST)"},{"number":"1018606","date":"2019-10-11","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-06-20","scope":"5 SPEAKERS,1AMP,3 VC'S AND 1 MUSIC PLAYER PER 2017 NEC (BANK)"},{"number":"1021445","date":"2019-10-24","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2019-10-24","scope":"CREATE TWO TENANT SPACES (SPACE 2A AND 2B0)FROM EXISTING SPACE 2. EACH FOR THE USE AS TAKE-OUT RESTAURANTS WITH ACCESSORY EXTERIOR SEATING AREAS. SEE KEY PLAN FOR LOCATIONS."},{"number":"1019471","date":"2019-10-31","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-10-31","scope":"FOR THE ERECTION OF TWO STATIC INTERNALLY ILLUMINATED ACCESSORY FLAT WALL SIGN ON AN EXISTING STRUCTURE (SIZE AND LOCATION AS SHOWN ON THE PLAN) SIGN ACCESSORY TO A FINANCIAL SERVICES IN SPACE # 2 IN AN EXISTING STRUCTURE WITH OTHER EXISTING USES AS PREVIOUSLY APPROVED."},{"number":"1019472","date":"2019-10-31","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2019-11-25","scope":"FOR THE ERECTION OF TWO STATIC INTERNALLY ILLUMINATED ACCESSORY FLAT WALL SIGN ON AN EXISTING STRUCTURE (DETAILS AS SHOWN ON THE PLAN) SIGN ACCESSORY TO A FINANCIAL SERVICES IN SPACE # 2 IN AN EXISTING STRUCTURE WITH OTHER EXISTING USES AS PREVIOUSLY APPROVED."},{"number":"1012662","date":"2019-11-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-11-26","scope":"INSTALL FIRE ALARM AS PER PLANS AND NFPA 72 AS PER 2008 NEC CODE--NEW WIRING THROUGHOUT AND DEVICE AS PER NFPA 72"},{"number":"1033655","date":"2019-12-13","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-01-25","scope":"FOR LEVEL II ALTERATIONS TO FITOUT TAKE OUT RESTAURANT TO INCLUDE NEW PARTITIONS, FIXTURES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL MEP AND FIRE SUPPRESSION WORK. **IEBC 2018** *NO SIGNS THIS PERMIT*"},{"number":"1037639-RI","date":"2019-12-26","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-11-24","scope":"INSTALL FIRE ALARM 400AMP 3 PHASE 120/208V SERVICE-LIGHTS, SWITCHES, RECEPTACLES OUTLETS, AIR CONDITIONER OUTLET INSTALL FIRE ALARM 400AMP 3 PHASE 120/208V SERVICE-LIGHTS, SWITCHES, RECEPTACLES OUTLETS, AIR CONDITIONER OUTLET"},{"number":"1027143","date":"2020-01-16","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-02-22","scope":"INSTALLATION OF A NEW DMP XR550E BURGLAR ALARM SYSTEM AND AN INSTALLTION OF A DMP LTE CELL RADIO (WHICH WILL BE INSTALLED ON THE DMP PANEL) THAT WILL BE CONNECTED TO THE CHASE BANK NETWORK PER 2017 NEC (NORTH DIST)"},{"number":"1045889-RI","date":"2020-01-30","work":"Rough-In","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-03-16","scope":"INSTALL 2 WATAER CLOSETS, 2 LAVS, 3 HAND SINK, 1 FOUR COMP-SINK, 1 GREASE TRAP, 1 FOOD PREP SINK, 1 MOP SINK, 5 FLOOR DRAINS, 3 INDIRECT FLOOR SINKS **BUILDING PERMIT# 1033655**"},{"number":"ZP-2020-000358","date":"2020-03-26","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Eating and Drinking Establishments - Take-Out Restaurant"},{"number":"1054617","date":"2020-05-13","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2023-10-13","scope":"INSTALLATION OF ONE (1) UL LISTED COMMERCIAL KITCHEN EXHAUST HOOD WITH SUPPLY/EXHAUST TIE-IN TO ONE (1) RETURN AIR FAN, ONE (1) EXHAUST FAN & ALL ASSOCIATED RETURN/EXHAUST DUCTWORK.***SEPARATE PERMIT SHALL BE REQUIRED FOR INSTALLATION OF AN APPROVED AUTOMATIC FIRE SUPRESSION SYSTEM***"},{"number":"1045889","date":"2020-07-01","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-07-07","scope":"INSTALL 2 WATAER CLOSETS, 2 LAVS, 3 HAND SINK, 1 FOUR COMP-SINK, 1 GREASE TRAP, 1 FOOD PREP SINK, 1 MOP SINK, 5 FLOOR DRAINS, 3 INDIRECT FLOOR SINKS **BUILDING PERMIT# 1033655**"},{"number":"MP-2020-002948","date":"2020-08-20","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-01-25","scope":"FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE 2 HEAT PUMPS, DIFFUSERS/REGISTERS/GRILLES, AND ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"FP-2020-001478","date":"2020-08-31","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2022-12-27","scope":"EZ STANDARDS KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. *FIVE GUYS 2B * (1054617 Mechanical) - (1033655 Building)"},{"number":"FP-2020-001457","date":"2020-09-11","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-01-25","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (28) Sprinkler head (SPACE B2s )"},{"number":"ZP-2020-006615","date":"2020-10-26","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"FOR THE ERECTION OF ONE (1) INTERNALLY ILLUMINATED ACCESSORY FLAT WALL SIGN IN AN EXISTING TANENT SPACE (SIZE AND LOCATION AS SHOWN ON PLAN)."},{"number":"GP-2020-009056","date":"2020-11-18","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2022-06-29","scope":"FOR THE ERECTION OF ONE (1) INTERNALLY ILLUMINATED ACCESSORY FLAT WALL SIGN IN AN EXISTING TANENT SPACE (SIZE AND LOCATION AS SHOWN ON PLAN). SIGN ACCESSORY TO A TAKE-OUT RESTAURANT IN SPACE 2B IN AN EXISTING STRUCTURE WITH OTHER EXISTING USES AS PREVIOUSLY APPROVED."},{"number":"1037639","date":"2020-11-24","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-12","scope":"INSTALL FIRE ALARM AS PER 2016 NFPA 72. INSTALL 400 AMP 3-PHASE 120/208V SERVICE, LIGHTS, SWITCHES, RECEPTACLES OUTLETS, AIR CONDITIONER OUTLET AS PER 2017 NEC."},{"number":"ZP-2021-014591","date":"2021-12-01","work":"New construction, addition, GFA change","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"FOR THE CREATION OF A PLATFORM TO HOLD THE EQUIPMENT ACCESSORY TO EXISTING TAKE-OUT RESTAURANT. SIZE AND LOCATION AS SHOWN IN THE APPLICATION."},{"number":"GM-2021-013617","date":"2021-12-07","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2022-06-13","scope":"EZ INTERIOR DEMOLITION- For the interior demolition on non-bearing partition wall and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; UNDERPINNING AND EXCAVATIONS (I.E. DIGGING IN BASEMENT). NO WORK PERMITTED IN THE BASEMENT. NO WORK TO RATED ASSEMBLIES. Separate Streets Department permit required for sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2021-006650","date":"2021-12-08","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-06-28","scope":"LEVEL II ALTERATIONS FOR FIT-OUT OF SPACE 202B FOR A RESTAURANT TO INCLUDE INTERIOR EQUIPMENT PLATFORM ADDITION AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK** AMENDMENT APPROVED 4/24/22 AMEND ALTERATIONS PERMIT NO. CP-2021-006650 FOR INTERIOR LAYOUT CHANGES AS PER APPROVED PLANS."},{"number":"PP-2021-023410","date":"2022-01-04","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-06-13","scope":"Plumbing Permit (Interior) for combo CP-2021-006650"},{"number":"MP-2021-008357","date":"2022-01-05","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-06-13","scope":"Mechanical / Fuel Gas Permit for combo CP-2021-006650"},{"number":"EP-2021-014629","date":"2022-01-13","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-06-01","scope":"Provide new 600 amp panel from existing landlord 1600 amp MDP. Install 225 amp subpanel. Provide power, lighting, and telecommunication wiring as per plans and 2017 NEC."},{"number":"FP-2022-000419","date":"2022-02-07","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-06-13","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (63) Sprinkler Heads (CP-2021-006650)"},{"number":"FP-2022-000358","date":"2022-02-21","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-06-24","scope":"EZ STANDARD KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. INSTALL (1) ONE WET CHEMICAL COMMERCIAL KITCHEN FIRE SUPPRESSION SYSTEM FOR PROTECTION OF KITCHEN EXHAUST HOOD - SEE MECHANICAL PERMIT MP-2021-008357 FOR KITCHEN HOOD."},{"number":"EP-2022-002102","date":"2022-03-13","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-06-10","scope":"Install fire alarm system for new restaurant in existing building as per plans as per 2016 NFPA 72"},{"number":"ZP-2022-000776","date":"2022-03-16","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Completed","completedDate":"2022-06-29","scope":"FOR THE INSTALLATION OF ONE (1) INTERNALLY ILLUMINATED WALL SIGN, AND TWO (2) ILLUMINATED WINDOW SIGNS. ALL PER APPROVED PLANS."},{"number":"GP-2022-002067","date":"2022-03-30","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2022-06-29","scope":"FOR THE INSTALLATION OF ONE (1) INTERNALLY ILLUMINATED WALL SIGN, AND TWO (2) ILLUMINATED WINDOW SIGNS. ALL PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK."},{"number":"CP-2024-003092","date":"2024-07-14","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-10-12","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A MERCHANTILE OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"PP-2024-009773","date":"2024-07-16","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-10-04","scope":"Plumbing Permit (Interior) for combo CP-2024-003092"},{"number":"MP-2024-003192","date":"2024-07-16","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-10-04","scope":"Mechanical / Fuel Gas Permit for combo CP-2024-003092"},{"number":"EP-2024-006867","date":"2024-07-19","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-26","scope":"Electrical Permit for combo CP-2024-003092"},{"number":"EP-2024-007052","date":"2024-07-24","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-24","scope":"Install security alarm devices throughout pharmacy area."},{"number":"FP-2024-001727","date":"2024-09-24","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-10-04","scope":"FOR THE INSTALLATION OF SIX (6) SRPINKLER HEADS IN THE EXISTING SYSTEM IN ACCORDANCE WITH NFPA 13. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."}],"storyTag":"Torn down & rebuilt","storyDelta":null,"timeline":[{"y":2022,"k":"permit","w":"Signs (Accessory / Non-Accessory)"},{"y":2022,"k":"permit","w":"Sign"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Alterations"},{"y":2024,"k":"permit","w":"Addition and/or Alterations"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"viol","w":"2 L&I violations"},{"y":2025,"k":"insp","w":"L&I: 4 failed, 1 passed"},{"y":2026,"k":"viol","w":"L&I violation"},{"y":2026,"k":"insp","w":"L&I: 1 failed, 1 passed"}],"rented":true,"licenses":[{"number":"826713","type":"Rental","status":"Active","businessName":"Southmoore Owner LLC (Vantage)","legalName":"Southmoore Owner LLC","address":"1101-37 CECIL B MOORE AVE","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":368,"issuedDate":"2019-10-16","latestIssueDate":"2025-10-02","expirationDate":"2026-10-15","inactiveDate":null},{"number":"893685","type":"Food Preparing and Serving","status":"Active","businessName":"Rockham 5G PA LP (Five Guys Burgers)","legalName":"Rockham 5G PA LP","address":"1101-37 CECIL B MOORE AVE","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2022-05-03","latestIssueDate":"2026-03-19","expirationDate":"2027-05-02","inactiveDate":null},{"number":"899703","type":"Food Establishment, Retail Permanent Location","status":"Active","businessName":"Raising Cane's Restaurants, LLC (Raising Cane's #824)","legalName":"Raising Cane's Restaurants, LLC","address":"1101-37 CECIL B MOORE AVE","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2022-06-29","latestIssueDate":"2026-06-17","expirationDate":"2027-06-28","inactiveDate":null},{"number":"899704","type":"Food Preparing and Serving (30+ SEATS)","status":"Active","businessName":"Raising Cane's Restaurants, LLC (Raising Cane's #824)","legalName":"Raising Cane's Restaurants, LLC","address":"1101-37 CECIL B MOORE AVE","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2022-06-29","latestIssueDate":"2026-06-29","expirationDate":"2027-06-28","inactiveDate":null},{"number":"0963599","type":"Handbill Distribution","status":"Active","businessName":"Southmoore Owner LLC (Vantage)","legalName":"Southmoore Owner LLC","address":"1101-37 CECIL B MOORE AVE","revenueCode":"3418","rentalCategory":null,"units":null,"issuedDate":"2024-10-17","latestIssueDate":"2025-09-18","expirationDate":"2026-10-16","inactiveDate":null}],"licenseActivity":[{"number":"0963599","type":"Handbill Distribution","businessName":"Southmoore Owner LLC (Vantage)","legalName":"Southmoore Owner LLC","issuedDate":"2024-10-17","latestIssueDate":"2025-09-18","closureDate":null,"expirationDate":"2026-10-16","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"899703","type":"Food Establishment, Retail Permanent Location","businessName":"Raising Cane's Restaurants, LLC (Raising Cane's #824)","legalName":"Raising Cane's Restaurants, LLC","issuedDate":"2022-06-29","latestIssueDate":"2026-06-17","closureDate":null,"expirationDate":"2027-06-28","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"899704","type":"Food Preparing and Serving (30+ SEATS)","businessName":"Raising Cane's Restaurants, LLC (Raising Cane's #824)","legalName":"Raising Cane's Restaurants, LLC","issuedDate":"2022-06-29","latestIssueDate":"2026-06-29","closureDate":null,"expirationDate":"2027-06-28","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"893685","type":"Food Preparing and Serving","businessName":"Rockham 5G PA LP (Five Guys Burgers)","legalName":"Rockham 5G PA LP","issuedDate":"2022-05-03","latestIssueDate":"2026-03-19","closureDate":null,"expirationDate":"2027-05-02","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"826713","type":"Rental","businessName":"Southmoore Owner LLC (Vantage)","legalName":"Southmoore Owner LLC","issuedDate":"2019-10-16","latestIssueDate":"2025-10-02","closureDate":null,"expirationDate":"2026-10-15","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true}],"businessLicenseSourceDate":"2026-07-25","units":368,"signals":[{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["6 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"building-certifications","level":"urgent","title":"A life-safety certification is deficient","finding":"Special Hazards Certification: Certified through Jun 30, 2027; Sprinkler Certification: Deficient; Fire Alarm Certification: Certified through Jun 30, 2027","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #165657: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"2 permits not marked completed: 1054617 (Expired), FP-2020-001478 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"rental-license","level":"verify","title":"A rental license does not transfer with the deed","finding":"1 active Rental License record matched.","why":"If dwelling space is rented, the buyer must obtain a new annual Rental License; the seller’s license is not transferable. New applications require proof of ownership and legal occupancy, tax compliance, no open L&I violations, and lead compliance where applicable.","action":"Plan the buyer’s replacement license before settlement.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"managing-agent","level":"verify","title":"Tax mail goes outside Philadelphia; owner residence still needs verification","finding":"OPA mails the property tax record outside Philadelphia (630 SENTRY PKWY, BLUE BELL PA, 19422).","why":"A tax mailing destination does not establish where the owner lives. If a rental owner lives outside Philadelphia, the City requires a managing agent with a Philadelphia mailing address; the owner remains legally responsible.","action":"Verify the buyer’s residence and, if the buyer will live outside Philadelphia, identify the Philadelphia managing agent on the new license application.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"5 failed, 2 passed, and 0 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Mar 17, 2026.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"deed-chain","level":"verify","title":"The latest nominal transfer is not a market sale—or a title opinion","finding":"The latest deed in the assembled record moved for nominal consideration.","why":"A $1 or nominal deed can be a valid family, estate, or entity transfer. It does not establish a sale price, clear title, or by itself prove a tangled title.","action":"Read the recorded deed and have the title search confirm every grantor, grantee, estate/probate step, lien, and authority to sell.","url":"https://www.phila.gov/services/property-lots-housing/get-a-copy-of-a-deed-or-other-recorded-document/"},{"id":"abatement","level":"verify","title":"A reduced taxable assessment is not a verified abatement","finding":"OPA’s numeric assessment fields show a reduced taxable assessment; BlockReport has no official program determination for this parcel.","why":"The numeric treatment can reflect an improvement abatement or another exemption. It does not identify the ordinance, approval, start or end date, or continuation requirements after a transfer. Once OPA verifies a specific active abatement, many common programs attach the benefit to the property for the remaining term rather than ending automatically at sale, but some require a new-owner filing and continued qualifying use or tax compliance.","action":"Obtain the OPA exemption/abatement determination and history, then underwrite the buyer’s bill from the verified program terms.","url":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/get-a-property-tax-abatement/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as apartments. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 3 historical violations across 2 cases.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}