{"asOf":"2026-07-28T23:24:18.508Z","block":"1600-1699 SANSOM ST","blockUrl":"https://philadelphia.blockreport.homes/block/1600-1699-sansom-st","address":"1605-27 SANSOM ST","parcelNumber":"881547010","source":"https://property.phila.gov/?p=881547010","ownerType":"investor","kind":"apartments","isHouse":false,"home":false,"commercial":true,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"CC0","buildingCodeNew":"830","buildingClass":"APTS 100+ UNITS MASONRY","buildingClassNew":"APARTMENTS - MID RISE","useLabel":"Apartment building","owner":"1605 SANSOM ASSOCIATES LLC","coOwner":null,"marketValue":28291400,"landAssessment":5658200,"improvementAssessment":22633200,"livableArea":88978,"yearBuilt":2013,"lastSale":{"price":31500000,"date":"2022-11-17T05:00:00Z"},"openViolations":0,"violations":[{"number":"2855996","date":"2013-07-10","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3625785","date":"2015-07-07","code":"PM-102.0/1","title":"LICENSE-RES GENERAL","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4647948","date":"2018-03-06","code":"FC-13-915.1","title":"FIRE ALARM TESTED/CERTIFIED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4980236","date":"2019-03-19","code":"FC-13-915.1","title":"FIRE ALARM TESTED/CERTIFIED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4980235","date":"2019-03-19","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5117792","date":"2019-05-22","code":"FC-13-907.2","title":"SINGLE STATION SMKE ALRM REQ'D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2025-000153","date":"2025-01-02","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2025-04-11","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"3147523","date":"2014-04-15","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"390465","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2013-07-10","completedDate":"2013-12-10","violations":[{"number":"2855996","date":"2013-07-10","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"489906","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-07-07","completedDate":"2015-08-11","violations":[{"number":"3625785","date":"2015-07-07","code":"PM-102.0/1","title":"LICENSE-RES GENERAL","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"624598","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2018-03-08","completedDate":"2018-06-04","violations":[{"number":"4647948","date":"2018-03-06","code":"FC-13-915.1","title":"FIRE ALARM TESTED/CERTIFIED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"677028","type":"HAZARDOUS","priority":"HAZARDOUS","responsibility":"HCEU","status":"CLOSED","createdDate":"2019-03-20","completedDate":"2019-06-24","violations":[{"number":"4980236","date":"2019-03-19","code":"FC-13-915.1","title":"FIRE ALARM TESTED/CERTIFIED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4980235","date":"2019-03-19","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"686539","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2019-05-22","completedDate":"2019-08-30","violations":[{"number":"5117792","date":"2019-05-22","code":"FC-13-907.2","title":"SINGLE STATION SMKE ALRM REQ'D","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2025-000258","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"AUDITS AND INVESTIGATIONS BUILDING CERTS","status":"CLOSED","createdDate":"2025-01-02","completedDate":"2025-04-11","violations":[{"number":"VI-2025-000153","date":"2025-01-02","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2025-04-11","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"507950","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3147523","date":"2014-04-15","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2013,"n":1,"worst":null},{"y":2014,"n":1,"worst":null},{"y":2015,"n":1,"worst":null},{"y":2018,"n":1,"worst":null},{"y":2019,"n":3,"worst":null},{"y":2025,"n":1,"worst":null}],"investigations":[{"caseNumber":"53279","date":"2006-02-02","type":"BC INSP","status":"CLOSED"},{"caseNumber":"390465","date":"2013-07-09","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"390465","date":"2013-12-10","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"489906","date":"2015-07-07","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"489906","date":"2015-08-11","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"624598","date":"2018-03-06","type":"CI INSP","status":"FAILED"},{"caseNumber":"624598","date":"2018-04-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"624598","date":"2018-05-25","type":"CI INSP","status":"PASSED"},{"caseNumber":"677028","date":"2019-03-19","type":"CI INSP","status":"FAILED"},{"caseNumber":"686539","date":"2019-05-22","type":"CI INSP","status":"FAILED"},{"caseNumber":"677028","date":"2019-06-21","type":"CI INSP","status":"PASSED"},{"caseNumber":"686539","date":"2019-07-23","type":"CI INSP","status":"FAILED"},{"caseNumber":"686539","date":"2019-08-29","type":"CI INSP","status":"PASSED"},{"caseNumber":"CF-2025-000258","date":"2025-01-02","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-000258","date":"2025-04-11","type":null,"status":"PASSED"}],"inspYears":[{"y":2013,"fails":1,"passes":1},{"y":2015,"fails":1,"passes":1},{"y":2018,"fails":2,"passes":1},{"y":2019,"fails":3,"passes":2},{"y":2025,"fails":1,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.950752592980734,"lng":-75.16813987337045,"geom":{"type":"Polygon","coordinates":[[[-75.167786213,39.950797869],[-75.167824199,39.950620633],[-75.168493824,39.950707212],[-75.168454785,39.950884683],[-75.167786213,39.950797869]]]},"liDistrict":"CENTRAL WEST","certifications":[{"number":"BC-2021-003863","type":"Special Hazards Certification","inspectionDate":"2021-09-10","result":"Certified","expirationDate":"2022-09-10","buildingId":"1509058"},{"number":"BC-2022-002857","type":"Fire Alarm Certification","inspectionDate":"2022-02-24","result":"Certified","expirationDate":"2023-02-24","buildingId":"1509058"},{"number":"BC-2023-012737","type":"Damper Certification","inspectionDate":"2023-06-14","result":"Certified","expirationDate":"2027-06-14","buildingId":"1509058"},{"number":"BC-2023-024518","type":"Sprinkler Certification","inspectionDate":"2023-09-20","result":"Certified","expirationDate":"2024-09-20","buildingId":"1509058"},{"number":"BC-2025-019800","type":"Sprinkler Certification","inspectionDate":"2024-09-23","result":"Certified","expirationDate":"2025-09-23","buildingId":"1509058"},{"number":"BC-2024-033687","type":"Emergency and Standby Power Systems Certification","inspectionDate":"2024-12-16","result":"Certified","expirationDate":"2025-12-16","buildingId":"1509058"},{"number":"BC-2025-004550","type":"Facade Report","inspectionDate":"2025-02-03","result":"Safe","expirationDate":"2030-02-03","buildingId":"1509058"},{"number":"BC-2026-001448","type":"Fire Alarm Certification","inspectionDate":"2025-12-09","result":"Certified","expirationDate":"2026-12-09","buildingId":"1509058"},{"number":"BC-2026-003176","type":"Emergency and Standby Power Systems Certification","inspectionDate":"2026-02-04","result":"Certified","expirationDate":"2027-02-04","buildingId":"1509058"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19103","beds":null,"baths":null,"stories":8,"lotArea":12350,"zoning":"CMX5","grade":"A-","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"801 OLD YORK RD, JENKINTOWN PA, 19046","mailOut":true,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR THE EXTENSION OF PREVIOUSLY GRANTED SPECIAL USE PERMIT FOR A TEMPORARY PUBLIC PARKING LOT FOR 37 VEHICLES INCLUDING TWO (2) ADA ACCESSIBLE SPACES.","status":"CLOSED","outcome":"Granted with conditions","date":"2007-12-21","number":"3882","relatedPermit":"105883"},{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF A NINE(9) STORY ATTACHED STRUCTURE(MAXIMUM HEIGHT NTE 99FEET 3 INCHES) WITH PARTIAL CELLAR, FIRST FLOOR RETAIL SPACES AS PERMITTED IN THE DISTRICT(USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY) FOR 122 DWELLING UNI","status":"CLOSED","outcome":"Granted with conditions","date":"2012-04-18","number":"17231","relatedPermit":"397330"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":1,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":20133700,"taxable":645547,"land":645547,"improvement":19488153,"taxableLand":645547,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":19488153},{"y":2017,"v":20133700,"taxable":645547,"land":645547,"improvement":19488153,"taxableLand":645547,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":19488153},{"y":2018,"v":37438400,"taxable":3743840,"land":3743840,"improvement":33694560,"taxableLand":3743840,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":33694560},{"y":2019,"v":38561500,"taxable":3856150,"land":3856150,"improvement":34705350,"taxableLand":3856150,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":34705350},{"y":2020,"v":39139900,"taxable":3913990,"land":3913990,"improvement":35225910,"taxableLand":3913990,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":35225910},{"y":2021,"v":39139900,"taxable":3913990,"land":3913990,"improvement":35225910,"taxableLand":3913990,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":35225910},{"y":2022,"v":39139900,"taxable":3913990,"land":3913990,"improvement":35225910,"taxableLand":3913990,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":35225910},{"y":2023,"v":39139900,"taxable":3913990,"land":3913990,"improvement":35225910,"taxableLand":3913990,"taxableImprovement":0,"exemptLand":0,"exemptImprovement":35225910},{"y":2024,"v":28500000,"taxable":28500000,"land":4275000,"improvement":24225000,"taxableLand":4275000,"taxableImprovement":24225000,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":27200000,"taxable":27200000,"land":4080000,"improvement":23120000,"taxableLand":4080000,"taxableImprovement":23120000,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":27200000,"taxable":27200000,"land":4080000,"improvement":23120000,"taxableLand":4080000,"taxableImprovement":23120000,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":28291400,"taxable":28291400,"land":5658200,"improvement":22633200,"taxableLand":5658200,"taxableImprovement":22633200,"exemptLand":0,"exemptImprovement":0}],"taxNow":380746,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"397330","date":"2012-04-27","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2012-04-27","scope":"FOR THE ERECTION OF A NINE(9) STORY ATTACHED STRUCTURE(MAXIMUM HEIGHT NTE 99FEET 3 INCHES) WITH PARTIAL CELLAR. (SIZE AND LOCATION AS SHOWN ON THE APPLICATION). FIRST FLOOR RETAIL SPACES AS PERMITTED IN THE DISTRICT(USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY) FOR 122 DWELLING UNITS ON FLOORS TWO THRU NINE, WITH A LOADING DOCK, CELLAR FOR MECHANICAL'S AND BICYCLE PARKING SPACES."},{"number":"404245","date":"2012-06-04","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-05-13","scope":"install 1 dvr,1 monitor,2 video cams,1 security panel,3 door contacts,2 motion detectors,1 egress button,1 key pad,1 siren as per 2008 nec"},{"number":"410809","date":"2012-06-13","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2013-04-23","scope":"DEMOLITION TO CREATE VACANT LOT. VACANT LOT"},{"number":"410812","date":"2012-06-13","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2012-07-06","scope":"COMPLETE DEMO OF 14X14 BUILDING TO CREATE VACANT SECURED LOT. CALL INSPECTOR PRIOR FOR AN INITIAL INSPECTION PRIOR TO THE START OF WORK."},{"number":"412344","date":"2012-06-22","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2013-06-30","scope":"FOUNDATION PERMIT ONLY AS PER SUBMITTED PLANS. OWNER ASSUMES RESPONSIBILITY FOR CONSTRUCTING THE FOUNDATION PRIOR TO OBTAINING ALL PREREQUISITE APPROVALS FOR THE REQUIRED BUILDING PERMIT. ZONING, BUILDING, ELECTRICAL, MECHANICAL, AND FIRE SUPPRESSION WORK REQUIRES ADDITIONAL PERMITS. CALL THE INSPECTOR PRIOR TO STARTING WORK."},{"number":"411724","date":"2012-07-11","work":"Zoning admin review","type":"ZP_ADMIN","description":"ZONING ADMIN REVIEW","status":"COMPLETED","completedDate":"2012-07-11","scope":"ZONING BOARD ADMINISTRATIVELY APPROVED AP # 387330, CALENDAR#17231 TO REDUCE THE OVERALL HEIGHT TO 89 FEET 7 INCHES, TO REDUCE THE DWELLING UNITS TO 104 DWELLING UNITS."},{"number":"407774","date":"2012-07-19","work":"New construction","type":"BP_NEWCNST","description":"NEW CONSTRUCTION PERMIT","status":"COMPLETED","completedDate":"2013-07-09","scope":"NEW 8 STORY BUILDING WITH 104 RESIDENTIAL APARTMENTS AND GROUND FLOOR COMMERCIAL SPACE AS PER SUBMITTED SEALED PLAN. SEE A/P # 412344 FOR FOUNDATION DOCUMENTATION. MAXIMUM FLOOR HEIGHT ABOVE GRADE IS NOT TO EXCEED 75 FEET. PLUMBING, ELECTRICAL, MECHANICAL, AND FIRE SUPRESSION WORK REQUIRES ADDITIONAL PERMITS. CALL THE INSPECTOR PRIOR TO STARTING WORK."},{"number":"419053","date":"2012-08-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-09","scope":"INSTALL 100A TEMPORARY SERVICE FOR CONSTRUCTION SITE FROM 7/30/12 TO 1/30/13 AS PER 208 NEC(APT)(CC DIST)"},{"number":"422548","date":"2012-08-16","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2012-09-17","scope":"ADMINISTRATIVE PERMIT TO AMEND NEW CONSTRUCTION PERMIT # 407774 TO CHANGE THE DECLARED VALUATION FROM 60,000,000 TO 6,000,000."},{"number":"429206","date":"2012-10-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-06-30","scope":"97 UNITS W/BATH GROU,SINK+WASHING MACHINE,7-\" W/2 BATH,SINK + WASH MACH,2 FD,7 RD (MULTI FAM)"},{"number":"433815","date":"2012-11-28","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2012-11-28","scope":"FOR THE ERECTION OF A ROOF DECK ABOVE THE 6TH FLOOR LEVEL. SIZE AND LOCATION AS SHOWN IN THE APPLICATION. ROOF DECK ACCESSORY TO AN EXISTING STRUCTURE (HEIGHT 89 FEET, 7 INCHES) WITH FIRST FLOOR RETAIL SPACES AND 104 DWELLING UNITS ON FLOORS TWO THROUGH EIGHT."},{"number":"431438","date":"2012-12-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-06-30","scope":"HVAC INCLUDING DUCTWORK AND MECHANICAL EQUIPMENT AS PER PLANS."},{"number":"431092","date":"2012-12-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"104-APT FIRE ALARMS & SERVICE & MECHANICAL IN RETAIL ONLY AS PER NEC 2008 & NFPA 72 (MIXED USE)"},{"number":"435659","date":"2013-01-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-06-30","scope":"INSTALLATION OF NFPA 13 SPRINKLER SYSTEM THROUGHOUT BUILDING WITH 6\" SERVICE, PUMP, AND STANDPIPES"},{"number":"449783","date":"2013-01-25","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2013-01-25","scope":"FOR A SIT DOWN RESTAURANT ON SPACE # A, PERSONAL SERVICE ON SPACE# B ( BEAUTY SALON)ON FIRST FLOOR IN THE SAME BUILDING WITH 104 DWELLING UNITS FROM 2ND THRU 08TH FLOOR."},{"number":"450066","date":"2013-02-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-09-10","scope":"INTERIOR ALTERATIONS TO CREATE NEW BEAUTY SALON AT FIRST FLOOR COMMERCIAL SPACE."},{"number":"449442","date":"2013-02-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-05-23","scope":"NEW SANI & STORM PIPING TO NEW APT BLDG(97 UNITS)PA1#20130180818"},{"number":"455749","date":"2013-03-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-08-30","scope":"TENANT FIT-OUT TO INCLUDE (6) WATER CLOSET (5) FLOOR DRAINS (1) MOP RECEP. (5) LAVATORIES (26) SINKS (2) WASHING MACHINES (1) URINAL (5) SHOWERS"},{"number":"465578","date":"2013-05-20","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-06-24","scope":"FOR INTERIOR FIT-OUT FOR ONE (1) STORY TENANT SPACE TO INCLUDE ERECTION OF PARTITIONS FOR KITCHEN, BAR, DINING ROOM, & TOILET ROOM SPACES, & INSTALLATION OF LIGHT-FRAME DECORATIVE CEILING; WORK AREA TO BE FULLY SPRINKLERED. NO CHANGE IN HEIGHT, AREA OR EXIST. ELEMENTS OF EXTERIOR FACADE PERMITTED HEREIN."},{"number":"472699","date":"2013-05-21","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-09-10","scope":"RELOCATION OF EXISTING 84 HEADS TO ACCOMODATE NEW CEILINGS"},{"number":"466311","date":"2013-05-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-08-05","scope":"INTERIOR RENOVATION 3 WC, 2 LAV, 1 UR, 12 FD, 1 MR, 4 SINKS,1 DISHWASHER"},{"number":"461379","date":"2013-06-18","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2013-07-17","scope":"AMEND PERMIT NUMBER 407774 TO REFLECT CHANGE IN THE REQUIRED TWO HOUR FIRE PROOFING OF THE STRUCTURAL STEEL COLUMNS AS PER THE SUBMITTED SEALED PLAN. SPECIAL INSPECTIONS TO CERTIFY THE INSTALLATION IS IN COMPLIANCE WITH U.L. DESIGN NUMBER Y615. CALL THE INSPECTOR TO SCHEDULE AN INSPECTION."},{"number":"478373","date":"2013-06-19","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2013-06-19","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY FOR UNITS 209,210,305,311,313,314,401,409,411,412,607,611,612 AND 613 ONLY"},{"number":"474705","date":"2013-06-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-27","scope":"116-DUPLEX RECPTS, 55- DED DUPLEX RECPT, 27- GFI, 2-NEW PANELS, 150-DOWNLIGHTS, 14-2X2, 10-WALL SCONES & 1-LIGHTING INVEWRTER & DIMMING AS PER NEC 2008 (RETAIL SPACE)"},{"number":"474701","date":"2013-06-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-27","scope":"FURNISH & INSTALL F/A DEVICES & EQUIPMENT AS PER PLANS & SPECS, 1-FACP, 3-PULLSTATIONS, 33-SMOKE DETECTORS, 9-HORN STROBES & 14-STROBES AS PER NEC 2008 & NFPA 72 (RETAIL SPACE)"},{"number":"475245","date":"2013-07-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-10","scope":"NEW HVAC SYSTEM INCLUDING DUCTWORK AND 65 REGISTERS/DIFFUSERS AS PER APPROVED PLANS."},{"number":"473053","date":"2013-07-30","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-08-30","scope":"ROUGH IN DOMESTIC WASTE AND VENT GAS AND INSTALL FIXTURES;1MS,1 URN,6 WC,5 LAV,12 HAIR WASH SINK,4 SH,8 SINKS,1 WASHER BX (HAIR SALON)"},{"number":"510746","date":"2014-01-10","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-08-11","scope":"AMEND PERMIT # 461379 PERTAINING TO VIOLATION/CASE #390465(ATTACHED) AS PER THE SEALED SUBMITTED PLAN. CALL THE INSPECTOR TO SCHEDULE AN INSPECTION."},{"number":"507950","date":"2014-01-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-08-06","scope":"FOR INTERIOR FIT-OUT OF AN EXISTING TENANT SPACE TO INCLUDE THE ERECTION OF INTERIOR, NON-BEARING PARTITIONS, KITCHEN, BAR, DINING ROOM & ACCESSIBLE TOILET FACILITIES. TENANT SPACE TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION SYSTEMS."},{"number":"518394","date":"2014-02-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-08-06","scope":"FOR THE INSTALLATION OF A NEW HVAC SYSTEM THROUGHOUT A RESTAURANT. SYSTEM TO INCLUDE NEW APPLIANCES, FANS, EXHAUSTS AND ALL SUPPLEMENTAL REGISTERS/DIFFUSERS AND DUCTWORK AS SHOWN IN APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEMS."},{"number":"528210","date":"2014-04-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-08-05","scope":"RELOCATE 40 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"520970","date":"2014-05-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-02-22","scope":"20 LIGHTS SWITCHES,63 LIGHT OPENINGS,41 OUTLETS AND 12 PHONE/DATA OUTLETS PER 2008 NEC. INSTALLATION TO COMPLY WITH ARTICLE 210.8(B)(2) OF THE 2008 NEC & 125A FEEDER TO PANEL PP-2 SHALL BE 4 #2 & 1 #6GROUND."},{"number":"518467","date":"2014-05-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-08-05","scope":"FOR THE INSTALLATION OF THREE (3) COMMERCIAL COOKING HOODS (8'-0\", 9'-6\" AND 3'-7.5\") LISTED TO UL-710 REQUIREMENTS AND ASSOCIATED FANS AND DUCT WORK PER PLANS. SEPARATE PERMIT FOR FIRE SUPPRESSION."},{"number":"518462","date":"2014-05-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-08-05","scope":"INSTALLATION OF ONE (1) COMMERCIAL COOKING EXTINGUISHING SYSTEMS PER NFPA 17A STANDARDS (SPACE A). SEPARATE MECHANICAL PERMIT FOR INSTALLATION OF HOODS."},{"number":"533803","date":"2014-07-08","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-07-08","scope":"FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED FLAT-WALL SIGN AND THE DOCUMENTATION OF THE INSTALLATION OF TWO (2) NON-ILLUMINATED WINDOW SIGNS. SIZE AND LOCATION AS SHOWN IN APPLICATION. FOR USE AS SIGNS ACCESSORY TO EXISTING SIT DOWN RESTAURANT IN SPACE \"A\" ON THE FIRST FLOOR IN THE SAME BUILDING WITH AN EXISTING PERSONAL SERVICES (BEAUTY SALON) IN SPACE \"B\" ON THE FIRST FLOOR AND MULTI-FAMILY HOUSEHOLD LIVING OF ONE HUNDRED FOUR (104) DWELLING UNITS ABOVE."},{"number":"547778","date":"2014-07-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-08-08","scope":"FOR THE ERECTION OF AN ALLUMINUM FRAME AWNING AND PAINTED ALUMINUM COVER (NO SIGN COPY) AS PER APPROVED PLANS. ***SEE A/P 533808 FOR PLANS***"},{"number":"533808","date":"2014-07-08","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2015-02-02","scope":"FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED FLAT WALL SIGN AND THE DOCUMENTATION OF THE INSTALLATION OF TWO (2) NON-ILLUMINATED WINDOW SIGNS AS PER APPROVED PLANS. SEPARATE ELECTRICAL PERMIT REQUIRED."},{"number":"534700","date":"2014-07-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-02-25","scope":"RELOCATING ONE HORN STROBE AND INSTALLING 2 NEW HORN STROBES,3 STROBES(RESTROOM) AND 2 PULL STATIONS PER 2008 NEC & NFPA 72(RESTAURANT)"},{"number":"948410","date":"2019-02-11","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2019-02-11","scope":"FOR A VISITOR ACCOMODATIONS IN UNIT# 201,214,215,703, 3D,4F,4H,5A,5D,6B,6C,6G,7G,8F,8G,10C,10H,11B,AND 12F FOR STAYS OF 30 DAYS OR LESS. BUT MORE THAN HUNDRED AND EIGHTY(180)DAYS IN A CALENDAR YEAR IN THE SAME BUILDING WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION."},{"number":"968775","date":"2019-04-22","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2019-04-22","scope":"FOR A VISITOR ACCOMODATIONS IN UNIT# 202,207,301,304, 307,313,401,405,505,700,802,7D,7B,8A,3H,9H,12C,12D AND 13CFOR STAYS OF 30 DAYS OR LESS. BUT MORE THAN HUNDRED AND EIGHTY(180)DAYS IN A CALENDAR YEAR IN THE SAME BUILDING WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION."},{"number":"968772","date":"2019-04-22","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2019-04-22","scope":"FOR THE VISITOR ACCOMODATIONS OF UNIT# 309 AS PART OF EXISTING MULTI-FAMILY HOUSEHOLD LIVING IN THE SAME LOT WITH ALL OTHER USES AS PREVIOUSLY APPROVED.NO SIGN ON THIS APPLICATION."},{"number":"CP-2021-000529","date":"2021-02-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-08-12","scope":"For the erection of a temporary structure in the right of way for use as restaurant seating; Separate Permit(s) required if new electrical connections or HVAC equipment is proposed; Upon issuance of this permit, the restaurant's Temporary Sidewalk Caf?/Streetery License must be amended to document the approval of the structure. Please submit this permit to https://form.jotform.com/203103777242045"},{"number":"CP-2023-003053","date":"2023-06-20","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-01-04","scope":"LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CREATE A SHELL COMMERCIAL SPACE (TENANT SPACE 'C') ON THE GROUND FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. SEPARATE USE REGISTRATION AND FIT-OUT PERMITS REQUIRED PRIOR TO OCCUPANCY. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK** AMENDMENT APPROVED 8/1/23 AMEND ALTERATIONS PERMIT CP-2023-003053 TO RELOCATE PROPOSED DEMISING WALL BASED ON EXISTING UTILITY ROOMS AS PER APPROVED PLANS."},{"number":"CP-2023-002291","date":"2023-06-22","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-01-26","scope":"FOR LEVEL 2 ALTERATION TO AN EXISTING RESTAURANT TO INCLUDE NEW STOREFRONT, NEW PARTITIONS, INTERIOR FINISHES, LIGHTING, AND NEW KITCHEN EQUIPMENT AS PER PLANS."},{"number":"PP-2023-009424","date":"2023-07-11","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-01-26","scope":"Furnish and install sanitary vent and domestic water piping to new plumbing fixtures, (3) floor drains, (2) indirect waste and (1) hand sink."},{"number":"MP-2023-003055","date":"2023-07-28","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2024-06-01","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2023-006649","date":"2023-08-02","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-01-16","scope":"Furnish and install 18 dedicated GFI's, 2 30-amp outlets, 1 exhaust fan, 1 MAU, 1 oven Furnish and install 13 pendant lights, 11 downlights, 6 track lights, 5 exits and 10 emergency heads Fire Alarm . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"FP-2023-001900","date":"2023-08-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-01-26","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating 29 sprinkler heads"},{"number":"CP-2023-004367","date":"2023-08-31","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-05-17","scope":"LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO AN EXISTING SALON ON THE GROUND FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"PP-2023-012832","date":"2023-09-15","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-01-04","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"FP-2023-002284","date":"2023-09-22","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-05-17","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (27) sprinklers to accommodate renovations to ground floor retail space"},{"number":"EP-2023-008544","date":"2023-09-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-12-18","scope":"INSTALL A 400 AMP 120/208V 3 PHASE SERVICE, 400 AMP PANEL & FEEDER. INSTALL LIGHTS NORMAL & EMERGENCY. INSTALL A RECEPTACLE. PROVIDE POWER FOR THE HVAC EQUIPMENT. INSTALL (2) 4\" CONDUITS FOR FUTURE LOW VOLTAGE. INSTALL NEW FIRE ALARM POWER SUPPLY & FIRE ALARM DEVICES CONNECTING TO THE EXISTING BUILDING FIRE ALARM PANEL. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. ** CORE & SHELL WORK ** NO FITOUT WORK."},{"number":"MP-2023-004114","date":"2023-10-03","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-01-04","scope":"FOR A MECHANICAL WORK TO ACCOMMODATE THE FIRST FLOOR OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"ZP-2023-009775","date":"2023-10-31","work":"New construction, addition, GFA change","type":"Zoning","description":"Zoning Permit","status":"Completed","completedDate":"2024-10-25","scope":"FOR THE EXPANSION OF EXISTING ROOF DECK AT SEVENTH FLOOR ACCESSORY TO RESIDENTIAL USE. SIZE AND LOCATION AS SHOWN ON PLANS."},{"number":"MP-2023-005393","date":"2023-12-14","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-05-17","scope":"FOR THE INSTALLATION OF REGISTERS/DIFFUSERS ASSOCIATED DUCT WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION"},{"number":"EP-2023-011995","date":"2023-12-27","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-05-06","scope":"Install 17 light fixture, 5 lighting tracks, 13 track light fixture, 17 emergency light, 6 exit, 21 switch, 1 time clock, 65 receptacle, 3 floor receptacle, 3 equipment power-2017 NEC. **Separate fire alarm permit req'd.**"},{"number":"PP-2024-000386","date":"2024-01-12","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-05-17","scope":"Replace (10) plumbing fixtures with new, (3) water closets, (6) treatment sinks, and (1) lavatory, connecting to existing piping. WITHOUT PIPING"},{"number":"EP-2024-001130","date":"2024-02-06","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-05-15","scope":"Fire Alarm: Install 4 smoke detector, 4 horn/strobe, 3 strobe . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"CP-2023-005047","date":"2024-02-15","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-10-25","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING ATTACHED STRUCTURE. ALTERATIONS TO INCLUDE THE 1ST FLOOR EXISTING LOBBY AREA AND ALTERATIONS FOR THE EXPANSION OF EXISTING ROOF DECK AT SEVENTH FLOOR ACCESSORY TO RESIDENTIAL USE. FOR USE AS AN EXISTING MIXED USES ON FIRST FLOOR WITH RESIDENTIAL USE ABOVE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. ***************** SEPARATE PERMTIS TO BE OBTAINED FOR ALL OTHER WORK. ****************************************** FOR THE EXPANSION OF EXISTING ROOF DECK AT SEVENTH FLOOR ACCESSORY TO RESIDENTIAL USE. EXISTING MIXED USES ON FIRST FLOOR WITH RESIDENTIAL USE ABOVE AS PREVIOUSLY APPROVED. AS PER APPROVED PLANS."},{"number":"EP-2024-002959","date":"2024-07-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-10-16","scope":"Replace existing light fixtures with new light fixtures in existing lobby. Relocate existing receptacle and data line to new desk location in lobby. Install lighting for metal wall panel display in lobby behind desk. Replace existing light fixtures on 7th floor roof deck. Install new circuit, receptacles, and light fixtures at new roof deck area on 7th floor, controlled by new time clock. Install new string lighting on 7th floor roof deck-2017 NEC."}],"storyTag":"Torn down & rebuilt","storyDelta":null,"timeline":[{"y":2023,"k":"permit","w":"Addition and/or Alterations"},{"y":2023,"k":"permit","w":"Addition and/or Alteration"},{"y":2023,"k":"permit","w":"Addition and/or Alterations"},{"y":2023,"k":"permit","w":"New construction, addition, GFA change"},{"y":2023,"k":"permit","w":"Addition and/or Alterations"},{"y":2023,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Alterations"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"viol","w":"L&I violation"},{"y":2025,"k":"insp","w":"L&I: 1 failed, 1 passed"}],"rented":true,"licenses":[{"number":"208482","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"MINAR PALACE INDIAN RESTAURANT INC","legalName":"MINAR PALACE INDIAN RESTAURANT INC","address":"1605-27 SANSOM ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2004-04-08","latestIssueDate":"2006-04-19","expirationDate":"2007-04-30","inactiveDate":"2012-12-22"},{"number":"315171","type":"Public Garage / Parking Lot","status":"Inactive","businessName":"GRANT PARKING JOINT VENTURE (FIVE STAR PARKING)","legalName":"GRANT PARKING JOINT VENTURE","address":"1605-27 SANSOM ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2005-11-14","latestIssueDate":"2012-02-18","expirationDate":"2012-12-31","inactiveDate":null},{"number":"563152","type":"Dumpster License - Private Property","status":"Inactive","businessName":"DIVISION PLACE HOSPITALITY GROUP LLC (HONEYGROW)","legalName":"DIVISION PLACE HOSPITALITY GROUP LLC","address":"1605-27 SANSOM ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2012-05-08","latestIssueDate":"2012-11-20","expirationDate":"2013-07-31","inactiveDate":null},{"number":"597470","type":"Dumpster License - Public ROW","status":"Inactive","businessName":"G2S2 ASSOCIATES LP","legalName":"G2S2 ASSOCIATES LP","address":"1605-27 SANSOM ST","revenueCode":"3417","rentalCategory":null,"units":null,"issuedDate":"2013-07-02","latestIssueDate":"2016-05-02","expirationDate":"2017-03-31","inactiveDate":"2017-05-30"},{"number":"606475","type":"Dumpster License - Public ROW","status":"Inactive","businessName":"JEAN MADELINE, INC.","legalName":"JEAN MADELINE, INC.","address":"1605-27 SANSOM ST","revenueCode":"3417","rentalCategory":null,"units":null,"issuedDate":"2013-10-15","latestIssueDate":"2016-04-29","expirationDate":"2017-03-31","inactiveDate":"2017-05-30"},{"number":"636238","type":"Rental","status":"Inactive","businessName":"G2S2 ASSOCIATES LP","legalName":"G2S2 ASSOCIATES LP","address":"1605-27 SANSOM ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":104,"issuedDate":"2014-07-25","latestIssueDate":"2022-02-24","expirationDate":"2023-02-28","inactiveDate":"2023-04-29"},{"number":"636295","type":"Food Preparing and Serving (30+ SEATS)","status":"Active","businessName":"ABE FISHER LLC","legalName":"ABE FISHER LLC","address":"1605-27 SANSOM ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2014-07-28","latestIssueDate":"2026-03-20","expirationDate":"2027-04-30","inactiveDate":null},{"number":"641482","type":"Sidewalk Cafe","status":"Active","businessName":"ABE FISHER LLC","legalName":"ABE FISHER LLC","address":"1605-27 SANSOM ST","revenueCode":"3123","rentalCategory":null,"units":null,"issuedDate":"2014-09-12","latestIssueDate":"2026-06-20","expirationDate":"2027-06-30","inactiveDate":null},{"number":"845144","type":"Sidewalk Cafe (Temporary)","status":"Inactive","businessName":"ABE FISHER LLC","legalName":"ABE FISHER LLC","address":"1605-27 SANSOM ST","revenueCode":"3123","rentalCategory":null,"units":null,"issuedDate":"2020-07-02","latestIssueDate":"2021-12-22","expirationDate":"2022-12-31","inactiveDate":"2023-03-01"},{"number":"940312","type":"Rental","status":"Active","businessName":"1605 Sansom Associates LLC","legalName":"1605 Sansom Associates LLC","address":"1605-27 SANSOM ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":104,"issuedDate":"2023-12-19","latestIssueDate":"2025-12-22","expirationDate":"2026-12-18","inactiveDate":null}],"licenseActivity":[{"number":"940312","type":"Rental","businessName":"1605 Sansom Associates LLC","legalName":"1605 Sansom Associates LLC","issuedDate":"2023-12-19","latestIssueDate":"2025-12-22","closureDate":null,"expirationDate":"2026-12-18","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"845144","type":"Sidewalk Cafe (Temporary)","businessName":"ABE FISHER LLC","legalName":"ABE FISHER LLC","issuedDate":"2020-07-02","latestIssueDate":"2021-12-22","closureDate":"2023-03-01","expirationDate":"2022-12-31","inactiveDate":"2023-03-01","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"641482","type":"Sidewalk Cafe","businessName":"ABE FISHER LLC","legalName":"ABE FISHER LLC","issuedDate":"2014-09-12","latestIssueDate":"2026-06-20","closureDate":null,"expirationDate":"2027-06-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"636295","type":"Food Preparing and Serving (30+ SEATS)","businessName":"ABE FISHER LLC","legalName":"ABE FISHER LLC","issuedDate":"2014-07-28","latestIssueDate":"2026-03-20","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"636238","type":"Rental","businessName":"G2S2 ASSOCIATES LP","legalName":"G2S2 ASSOCIATES LP","issuedDate":"2014-07-25","latestIssueDate":"2022-02-24","closureDate":"2023-04-29","expirationDate":"2023-02-28","inactiveDate":"2023-04-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"606475","type":"Dumpster License - Public ROW","businessName":"JEAN MADELINE, INC.","legalName":"JEAN MADELINE, INC.","issuedDate":"2013-10-15","latestIssueDate":"2016-04-29","closureDate":"2017-05-30","expirationDate":"2017-03-31","inactiveDate":"2017-05-30","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"597470","type":"Dumpster License - Public ROW","businessName":"G2S2 ASSOCIATES LP","legalName":"G2S2 ASSOCIATES LP","issuedDate":"2013-07-02","latestIssueDate":"2016-05-02","closureDate":"2017-05-30","expirationDate":"2017-03-31","inactiveDate":"2017-05-30","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"563152","type":"Dumpster License - Private Property","businessName":"DIVISION PLACE HOSPITALITY GROUP LLC (HONEYGROW)","legalName":"DIVISION PLACE HOSPITALITY GROUP LLC","issuedDate":"2012-05-08","latestIssueDate":"2012-11-20","closureDate":"2013-07-31","expirationDate":"2013-07-31","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"315171","type":"Public Garage / Parking Lot","businessName":"GRANT PARKING JOINT VENTURE (FIVE STAR PARKING)","legalName":"GRANT PARKING JOINT VENTURE","issuedDate":"2005-11-14","latestIssueDate":"2012-02-18","closureDate":"2012-12-31","expirationDate":"2012-12-31","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"208482","type":"Food Preparing and Serving (30+ SEATS)","businessName":"MINAR PALACE INDIAN RESTAURANT INC","legalName":"MINAR PALACE INDIAN RESTAURANT INC","issuedDate":"2004-04-08","latestIssueDate":"2006-04-19","closureDate":"2012-12-22","expirationDate":"2007-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-27","units":104,"signals":[{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["10 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Appeal #3882: CLOSED · Granted with conditions; related permit 105883. Use permit #397330: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"2 permits not marked completed: 404245 (Expired), MP-2023-003055 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"attention","title":"A life-safety certification appears expired","finding":"Special Hazards Certification: Certified through Sep 10, 2022; Fire Alarm Certification: Certified through Dec 9, 2026; Damper Certification: Certified through Jun 14, 2027; Sprinkler Certification: Certified through Sep 23, 2025; Emergency and Standby Power Systems Certification: Certified through Feb 4, 2027; Facade Report: Safe through Feb 3, 2030","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"rental-license","level":"verify","title":"A rental license does not transfer with the deed","finding":"1 active Rental License record matched.","why":"If dwelling space is rented, the buyer must obtain a new annual Rental License; the seller’s license is not transferable. New applications require proof of ownership and legal occupancy, tax compliance, no open L&I violations, and lead compliance where applicable.","action":"Plan the buyer’s replacement license before settlement.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"managing-agent","level":"verify","title":"Tax mail goes outside Philadelphia; owner residence still needs verification","finding":"OPA mails the property tax record outside Philadelphia (801 OLD YORK RD, JENKINTOWN PA, 19046).","why":"A tax mailing destination does not establish where the owner lives. If a rental owner lives outside Philadelphia, the City requires a managing agent with a Philadelphia mailing address; the owner remains legally responsible.","action":"Verify the buyer’s residence and, if the buyer will live outside Philadelphia, identify the Philadelphia managing agent on the new license application.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"8 failed, 6 passed, and 1 CLOSED investigation outcome are in the fetched history; the latest dated visit was PASSED on Apr 11, 2025.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Preparing and Serving (30+ SEATS) #208482: Inactive since Dec 22, 2012; Public Garage / Parking Lot #315171: Inactive; Dumpster License - Private Property #563152: Inactive; Dumpster License - Public ROW #597470: Inactive since May 30, 2017","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as apartments. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 8 historical violations across 7 cases.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}