{"asOf":"2026-07-25T14:04:11.691Z","block":"2100-2199 COTTMAN AVE","blockUrl":"https://philadelphia.blockreport.homes/block/2100-2199-cottman-ave","address":"2118 COTTMAN AVE","parcelNumber":"882077100","source":"https://property.phila.gov/?p=882077100","ownerType":"investor","kind":"commercial","isHouse":false,"home":false,"commercial":true,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"MC0","buildingCodeNew":"233","buildingClass":"SHOP CENT AREA MASONRY","buildingClassNew":"STRIP SHOPPING CENTER","useLabel":"Store","owner":"COTTMAN REALTY ASSOCIATES","coOwner":null,"marketValue":11167800,"landAssessment":7817400,"improvementAssessment":3350400,"livableArea":31908,"yearBuilt":1950,"lastSale":{"price":4400000,"date":"2001-11-06T05:00:00Z"},"openViolations":0,"violations":[{"number":"1698433","date":"2010-04-22","code":"FC-703.1/5","title":"FIRE-DOOR/HARDWARE MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1698432","date":"2010-04-22","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2416557","date":"2011-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2416558","date":"2011-01-20","code":"FC-912.2/1","title":"FIRE CONNECT SIGN-EXIST BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2416559","date":"2011-01-20","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2416561","date":"2011-01-31","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2517733","date":"2011-10-09","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2366743","date":"2011-10-25","code":"09-610.1/3","title":"MASSEUR/MASSEUSE LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2366744","date":"2011-10-25","code":"14-1605/13","title":"MASSAGE BUSINESS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2501891","date":"2012-07-09","code":"A-301.1/46","title":"PERMB- INSTALL HVAC SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2501892","date":"2012-07-09","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2572490","date":"2012-09-12","code":"A-301.1/67","title":"PERMB- CONST MASONRY FENCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2612266","date":"2012-09-12","code":"A-301.1/52","title":"PERME- INST COMMUN WIRE/EQUIP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2772903","date":"2012-11-01","code":"PM-307.1/12","title":"WALL PARTIALLY COLLAPSED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3281186","date":"2014-08-05","code":"A-501.1/5","title":"LISTED CONDIT DOES NOT COMPLY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3904558","date":"2016-03-11","code":"FC-904.11/4","title":"AFES-COMM KITCH SERVICE & CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3868062","date":"2016-03-11","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3868061","date":"2016-03-11","code":"14-1704/50","title":"NO ZONING/USE PERMIT-SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2024-053437","date":"2024-06-27","code":"PM15-308.1","title":"RUBBISH & GARBAGE","status":"COMPLIED","resolutionDate":"2024-07-19","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2026-036102","date":"2026-05-27","code":"PM15-308.1","title":"RUBBISH & GARBAGE","status":"COMPLIED","resolutionDate":"2026-06-10","resolution":"COMPLIED - OWNER REPAIR"},{"number":"3281090","date":"2014-08-04","code":"A-501.1/5","title":"LISTED CONDIT DOES NOT COMPLY","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3303929","date":"2014-08-22","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"232552","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2010-04-23","completedDate":"2014-12-11","violations":[{"number":"1698433","date":"2010-04-22","code":"FC-703.1/5","title":"FIRE-DOOR/HARDWARE MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1698432","date":"2010-04-22","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"264545","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-01-24","completedDate":"2012-06-20","violations":[{"number":"2416557","date":"2011-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2416558","date":"2011-01-20","code":"FC-912.2/1","title":"FIRE CONNECT SIGN-EXIST BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2416559","date":"2011-01-20","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"265272","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-02-03","completedDate":"2016-07-20","violations":[{"number":"2416561","date":"2011-01-31","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"301184","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2011-10-09","completedDate":"2014-12-11","violations":[{"number":"2517733","date":"2011-10-09","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"303566","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2011-10-26","completedDate":"2012-02-27","violations":[{"number":"2366743","date":"2011-10-25","code":"09-610.1/3","title":"MASSEUR/MASSEUSE LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2366744","date":"2011-10-25","code":"14-1605/13","title":"MASSAGE BUSINESS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"338279","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2012-07-12","completedDate":"2012-08-13","violations":[{"number":"2501891","date":"2012-07-09","code":"A-301.1/46","title":"PERMB- INSTALL HVAC SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2501892","date":"2012-07-09","code":"A-901.13/1","title":"PENALTY- NO BLDG PERM INFO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"349643","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2012-09-12","completedDate":"2012-09-26","violations":[{"number":"2572490","date":"2012-09-12","code":"A-301.1/67","title":"PERMB- CONST MASONRY FENCE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"349651","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2012-09-12","completedDate":"2012-11-14","violations":[{"number":"2612266","date":"2012-09-12","code":"A-301.1/52","title":"PERME- INST COMMUN WIRE/EQUIP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"357712","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2012-11-01","completedDate":"2013-09-26","violations":[{"number":"2772903","date":"2012-11-01","code":"PM-307.1/12","title":"WALL PARTIALLY COLLAPSED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"446368","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DE","status":"CLOSED","createdDate":"2014-08-05","completedDate":"2014-08-27","violations":[{"number":"3281186","date":"2014-08-05","code":"A-501.1/5","title":"LISTED CONDIT DOES NOT COMPLY","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"523728","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-03-14","completedDate":"2016-04-21","violations":[{"number":"3904558","date":"2016-03-11","code":"FC-904.11/4","title":"AFES-COMM KITCH SERVICE & CERT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"523740","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-03-14","completedDate":"2016-03-28","violations":[{"number":"3868062","date":"2016-03-11","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3868061","date":"2016-03-11","code":"14-1704/50","title":"NO ZONING/USE PERMIT-SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2024-068361","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2024-06-27","completedDate":"2024-07-19","violations":[{"number":"VI-2024-053437","date":"2024-06-27","code":"PM15-308.1","title":"RUBBISH & GARBAGE","status":"COMPLIED","resolutionDate":"2024-07-19","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2026-059254","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2026-05-27","completedDate":"2026-06-10","violations":[{"number":"VI-2026-036102","date":"2026-05-27","code":"PM15-308.1","title":"RUBBISH & GARBAGE","status":"COMPLIED","resolutionDate":"2026-06-10","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"549272","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3281090","date":"2014-08-04","code":"A-501.1/5","title":"LISTED CONDIT DOES NOT COMPLY","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"551275","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3303929","date":"2014-08-22","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2010,"n":2,"worst":null},{"y":2011,"n":7,"worst":null},{"y":2012,"n":5,"worst":null},{"y":2014,"n":3,"worst":null},{"y":2016,"n":3,"worst":null},{"y":2024,"n":1,"worst":null},{"y":2026,"n":1,"worst":null}],"investigations":[{"caseNumber":"29905","date":"2004-08-04","type":"L_CLIP","status":"FAILED"},{"caseNumber":"29905","date":"2004-08-19","type":"L_CLIP","status":"CLOSED"},{"caseNumber":"35564","date":"2005-01-04","type":"L_CLIP","status":"FAILED"},{"caseNumber":"35564","date":"2005-01-20","type":"L_CLIP","status":"CLOSED"},{"caseNumber":"232552","date":"2010-04-22","type":"CI INSP","status":"FAILED"},{"caseNumber":"232552","date":"2010-05-26","type":"CI INSP","status":"FAILED"},{"caseNumber":"232552","date":"2010-06-29","type":"CI INSP","status":"PASSED"},{"caseNumber":"264545","date":"2011-01-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"265272","date":"2011-01-31","type":"CI INSP","status":"FAILED"},{"caseNumber":"265272","date":"2011-09-21","type":"CI INSP","status":"FAILED"},{"caseNumber":"264545","date":"2011-09-21","type":"CI INSP","status":"FAILED"},{"caseNumber":"301184","date":"2011-10-07","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"303566","date":"2011-10-25","type":"BC INSP","status":"FAILED"},{"caseNumber":"264545","date":"2011-10-31","type":"CI INSP","status":"CLOSED"},{"caseNumber":"265272","date":"2011-10-31","type":"CI INSP","status":"PASSED"},{"caseNumber":"301184","date":"2011-11-07","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"303566","date":"2011-12-07","type":"BC INSP","status":"FAILED"},{"caseNumber":"301184","date":"2011-12-23","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"301184","date":"2012-02-01","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"303566","date":"2012-02-22","type":"PRECOURT","status":"PASSED"},{"caseNumber":"303566","date":"2012-02-22","type":"BC INSP","status":"CLOSED"},{"caseNumber":"264545","date":"2012-04-19","type":"PRECOURT","status":"FAILED"},{"caseNumber":"265272","date":"2012-04-19","type":"PRECOURT","status":"FAILED"},{"caseNumber":"265272","date":"2012-04-26","type":"PRECOURT","status":"PASSED"},{"caseNumber":"264545","date":"2012-06-15","type":"PRECOURT","status":"PASSED"},{"caseNumber":"338279","date":"2012-07-09","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"301184","date":"2012-07-27","type":"PRECOURT","status":"PASSED"},{"caseNumber":"301184","date":"2012-08-08","type":"PRECOURT","status":"PASSED"},{"caseNumber":"338279","date":"2012-08-13","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"301184","date":"2012-08-13","type":"PRECOURT","status":"PASSED"},{"caseNumber":"349643","date":"2012-09-12","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"349651","date":"2012-09-12","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"349643","date":"2012-09-25","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"349651","date":"2012-10-17","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"357712","date":"2012-11-01","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"349651","date":"2012-11-14","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"357712","date":"2013-01-07","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"357712","date":"2013-03-12","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"357712","date":"2013-03-15","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"357712","date":"2013-04-24","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"357712","date":"2013-09-24","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"446368","date":"2014-08-04","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"446368","date":"2014-08-27","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"523740","date":"2016-03-11","type":"CI INSP","status":"FAILED"},{"caseNumber":"523728","date":"2016-03-11","type":"CI INSP","status":"FAILED"},{"caseNumber":"523740","date":"2016-03-24","type":"CI INSP","status":"PASSED"},{"caseNumber":"523728","date":"2016-04-19","type":"CI INSP","status":"FAILED"},{"caseNumber":"523728","date":"2016-04-21","type":"CI INSP","status":"PASSED"},{"caseNumber":"CF-2024-068361","date":"2024-06-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-068361","date":"2024-07-19","type":null,"status":"PASSED"},{"caseNumber":"CF-2026-059254","date":"2026-05-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-059254","date":"2026-06-10","type":null,"status":"PASSED"}],"inspYears":[{"y":2004,"fails":1,"passes":0},{"y":2005,"fails":1,"passes":0},{"y":2010,"fails":2,"passes":1},{"y":2011,"fails":9,"passes":1},{"y":2012,"fails":7,"passes":10},{"y":2013,"fails":2,"passes":3},{"y":2014,"fails":1,"passes":1},{"y":2016,"fails":3,"passes":2},{"y":2024,"fails":1,"passes":1},{"y":2026,"fails":1,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":40.04907651950287,"lng":-75.06327467566945,"geom":{"type":"Polygon","coordinates":[[[-75.062593418,40.049047858],[-75.06300924,40.048616822],[-75.063238871,40.048717771],[-75.063388425,40.048726847],[-75.063398133,40.048794198],[-75.063953421,40.049108553],[-75.063522401,40.04956166],[-75.062593418,40.049047858]]]},"liDistrict":"EAST","certifications":[{"number":"BC-2021-005198","type":"Fire Alarm Certification","inspectionDate":"2021-09-14","result":"Certified","expirationDate":"2022-09-14","buildingId":"1268090"},{"number":"BC-2021-006798","type":"Special Hazards Certification","inspectionDate":"2021-11-12","result":"Certified","expirationDate":"2022-11-12","buildingId":"1268090"},{"number":"BC-2022-006119","type":"Special Hazards Certification","inspectionDate":"2022-05-06","result":"Certified","expirationDate":"2023-05-06","buildingId":"1268090"},{"number":"BC-2022-016180","type":"Fire Alarm Certification","inspectionDate":"2022-09-29","result":"Certified","expirationDate":"2023-09-29","buildingId":"1268090"},{"number":"BC-2022-017151","type":"Special Hazards Certification","inspectionDate":"2022-11-17","result":"Certified","expirationDate":"2023-11-17","buildingId":"1268090"},{"number":"BC-2023-010541","type":"Sprinkler Certification","inspectionDate":"2023-05-01","result":"Certified","expirationDate":"2024-05-01","buildingId":"1268090"},{"number":"BC-2023-010000","type":"Special Hazards Certification","inspectionDate":"2023-05-09","result":"Certified","expirationDate":"2024-05-09","buildingId":"1268090"},{"number":"BC-2023-019714","type":"Fire Alarm Certification","inspectionDate":"2023-09-15","result":"Certified","expirationDate":"2024-09-15","buildingId":"1268090"},{"number":"BC-2023-022349","type":"Special Hazards Certification","inspectionDate":"2023-11-01","result":"Certified","expirationDate":"2024-11-01","buildingId":"1268090"},{"number":"BC-2024-012524","type":"Sprinkler Certification","inspectionDate":"2024-04-18","result":"Certified","expirationDate":"2025-04-18","buildingId":"1268090"},{"number":"BC-2024-012393","type":"Special Hazards Certification","inspectionDate":"2024-05-01","result":"Certified","expirationDate":"2025-05-01","buildingId":"1268090"},{"number":"BC-2024-025225","type":"Fire Alarm Certification","inspectionDate":"2024-09-13","result":"Certified","expirationDate":"2025-09-13","buildingId":"1268090"},{"number":"BC-2024-025216","type":"Fire Alarm Certification","inspectionDate":"2024-09-13","result":"Certified","expirationDate":"2025-09-13","buildingId":"1268090"},{"number":"BC-2024-029549","type":"Special Hazards Certification","inspectionDate":"2024-11-01","result":"Certified","expirationDate":"2025-11-01","buildingId":"1268090"},{"number":"BC-2025-012506","type":"Special Hazards Certification","inspectionDate":"2025-05-08","result":"Certified","expirationDate":"2026-05-08","buildingId":"1268090"},{"number":"BC-2025-012480","type":"Special Hazards Certification","inspectionDate":"2025-05-08","result":"Certified","expirationDate":"2026-05-08","buildingId":"1268090"},{"number":"BC-2025-025761","type":"Fire Alarm Certification","inspectionDate":"2025-09-23","result":"Certified","expirationDate":"2026-09-23","buildingId":"1268090"},{"number":"BC-2025-029134","type":"Special Hazards Certification","inspectionDate":"2025-11-05","result":"Certified","expirationDate":"2026-11-05","buildingId":"1268090"},{"number":"BC-2026-012706","type":"Fire Alarm Certification","inspectionDate":"2026-02-25","result":"Deficient","expirationDate":null,"buildingId":"1268090"},{"number":"BC-2026-013703","type":"Special Hazards Certification","inspectionDate":"2026-05-13","result":"Certified","expirationDate":"2027-05-13","buildingId":"1268090"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19149","beds":null,"baths":null,"stories":1,"lotArea":65653,"zoning":"CA1","grade":"C+","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"276 POST RD W, WESTPORT CT, 06880","mailOut":true,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR ADDING MASSAGE THERAPY IN SPACE # 2&3 AS PART OF AN EXISTING TANNING SALON AND VIDEO STORE AS PART OF AN EXISTING AREA SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APPROVED.","status":"CLOSED","outcome":"Granted with conditions","date":"2012-05-15","number":"17020","relatedPermit":"375038"},{"type":"Zoning board appeal","grounds":"SPECIAL EXCEPTION FOR A TAKE-OUT RESTAURANT ON SPACE #2  AS PART OF EXISTING AREA SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION.","status":"CLOSED","outcome":"Granted with conditions","date":"2014-10-01","number":"23537","relatedPermit":"547255"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":1,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":3377900,"taxable":3377900,"land":984800,"improvement":2393100,"taxableLand":984800,"taxableImprovement":2393100,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":3377900,"taxable":3377900,"land":984800,"improvement":2393100,"taxableLand":984800,"taxableImprovement":2393100,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":4092700,"taxable":4092700,"land":818540,"improvement":3274160,"taxableLand":818540,"taxableImprovement":3274160,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":3984800,"taxable":3984800,"land":796960,"improvement":3187840,"taxableLand":796960,"taxableImprovement":3187840,"exemptLand":0,"exemptImprovement":0},{"y":2020,"v":3984800,"taxable":3984800,"land":796960,"improvement":3187840,"taxableLand":796960,"taxableImprovement":3187840,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":3984800,"taxable":3984800,"land":796960,"improvement":3187840,"taxableLand":796960,"taxableImprovement":3187840,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":3984800,"taxable":3984800,"land":796960,"improvement":3187840,"taxableLand":796960,"taxableImprovement":3187840,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":4440000,"taxable":4440000,"land":888000,"improvement":3552000,"taxableLand":888000,"taxableImprovement":3552000,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":4440000,"taxable":4440000,"land":888000,"improvement":3552000,"taxableLand":888000,"taxableImprovement":3552000,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":4786200,"taxable":4786200,"land":957240,"improvement":3828960,"taxableLand":957240,"taxableImprovement":3828960,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":4786200,"taxable":4786200,"land":957240,"improvement":3828960,"taxableLand":957240,"taxableImprovement":3828960,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":11167800,"taxable":11167800,"land":7817400,"improvement":3350400,"taxableLand":7817400,"taxableImprovement":3350400,"exemptLand":0,"exemptImprovement":0}],"taxNow":66997,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"76031","date":"2007-06-27","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2007-06-27","scope":"FOR THE ERECTION OF ONE (1) FLATWALL SIGN (2'X20') ON SPACE #5 AND FOR THE REFACE OF A PANEL (3'X8' EACH SIDE) ON AN EXISTING (8'X10') DOUBLE FACED PYLON SIGN, (SIZE AND LOCATION AS SHOWN IN THE APPLICATION). SIGNS ACCESSORY TO A FINANCIAL INSTITUTION (BANK) IN SPACE #5 AS PART OF AN EXISTING SHOPPING CENTER."},{"number":"79629","date":"2007-07-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"INTERIOR RENOVATIONS"},{"number":"90562","date":"2007-07-19","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2007-07-19","scope":"RETAIL SALES OF CELLULAR PHONES AND RELATED ACCESSORIES IN UNIT 5 OF AN EXISTING SHOPPING CENTER WITH USES AS PREVIOUSLY APPROVED."},{"number":"90519","date":"2007-08-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-09-27","scope":"TENANT FIT-OUT FOR RETAIL SALES OF PHONES"},{"number":"96187","date":"2007-08-14","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-10-24","scope":"MAKE RENOVATION TO EXISTING 1 STORY BUILDING, INSTALL NEW DRAIN LINES, VENT, HOT & COLD WATER, MAKE CONNECTION TO EXISTING PIPING, NEW 2 WC, 2 LAVYS, 1 MOP RECEPTOR, 1 KITCHEN SINK, 1 HWH"},{"number":"97627","date":"2007-08-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-09-27","scope":"RELOCATE ( 40) HEADS"},{"number":"97698","date":"2007-08-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-09-21","scope":"ISNTALL 2 LAVYS AND 2 WATER CLOSETS"},{"number":"94842","date":"2007-08-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-28","scope":"RENOVATIONS OF RETAIL SPACE USING THE EXISTING. INSTALLING 20 NEW LIGHTING, HVAC POWER, 20 RECEPTS AND 15 VOICE/DATA OUTLETS (EAST DIST)"},{"number":"98009","date":"2007-09-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-09-27","scope":"INSTALL AN HVAC SYSTEM AS PER PLANS"},{"number":"97843","date":"2007-09-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"ADDING 100 NEW LIGHT FIXTURES, ADDING 50 NEW RECEPTACLES, ADDING 4 NEW PANELS. (EAST DIST)"},{"number":"105874","date":"2007-10-02","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2007-10-02","scope":"FOR THE ERECTION OF ONE (1) FLATWALL SIGN (3'-0\" X 17'-10 1/2\") AND FOR THE REFACE OF A PANEL (3'X8' EACH SIDE) ON AN EXISTING (8'X10') DOUBLE FACED PYLON SIGN, (SIZE AND LOCATION AS SHOWN IN THE APPLICATION). SIGNS ACCESSORY TO A CELLULAR PHONE STORE AND RELATED ACCESSORIES IN SPACE #4 AS PART OF AN EXISTING SHOPPING CENTER."},{"number":"100995","date":"2007-10-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"HVAC INCLUDING DUCTWORK"},{"number":"106763","date":"2007-10-18","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2007-12-21","scope":"ERECT A FLAT WALL SIGN AND REFACE A DOUBLE FACED PYLON SIGN."},{"number":"111005","date":"2007-10-23","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-09-11","scope":null},{"number":"366264","date":"2011-10-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-10-17","scope":"RELOCATION OF EIGHT SPRINKLER HEADS. NO OTHER WORK ALLOWED UNDER THIS PERMIT."},{"number":"375038","date":"2012-05-29","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2012-05-29","scope":"FOR THE ADDIING MASSAGE THEREPY IN SPACE # 2&3 AS PART OF AN EXISTING TANNING SALON AND VIDEO STORE AS PART OF AN EXISTING AREA SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APPROVED"},{"number":"409568","date":"2012-06-07","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2012-06-07","scope":"FOR THE RETAIL SALE OF OPTICAL GOODS TO INCLUDE EXAMINATIONS WITH ACCESSORY OFFICES AND LENS PREP AREA IN SPACE #7 WITHIN AN EXISTING SHOPPING CENTER."},{"number":"412965","date":"2012-06-25","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2012-06-25","scope":"FOR THE CREATION OF TWO (2) TENANT SPACES (SPACE 8 AND SPACE 9) FROM ONE TENANT SPACE (SPACE 8). SPACE 8 WILL BE VACANT. USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY. SPACE 9 FOR THE TREATMENT OF PATIENTS WITH THE RETAIL SALE OF EYE GLASSES AS PART OF AN EXISTING SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGNS ON THIS PERMIT."},{"number":"411188","date":"2012-06-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"INT ALT TO A RETAIL STORE"},{"number":"413303","date":"2012-07-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-02-14","scope":"33 LAY-IN LTS,2 EMERG LTS,5 SW,10 RECEPTS,2 BATH FANS,400A MCB PANEL,3 GFCI RECEPTS ON ROOF,WIRE AND CONNECT RTV 1 AND 2 PER 2008 NEC(SHOPPING CENTER)(EAST DIST)"},{"number":"414737","date":"2012-07-05","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-08-08","scope":"INSTALLING 2 BATHROOM AND 1 WATER COOLER, WATER CLOSET, AND DRAIN LINES"},{"number":"416080","date":"2012-07-13","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"RELOCATE 8 SPRINKLER HEADS (SUITE #8)"},{"number":"416088","date":"2012-07-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"COMPLETE HVAC SYSTEM. 2 ROOFTOP UNITS WITH DUCTWORK AS PER PLAN."},{"number":"409609","date":"2012-07-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"NON STRUCTURAL TENANT FIT OUT OF OPTICAL GOODS STORE AS PER PLAN."},{"number":"418766","date":"2012-08-17","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2012-08-17","scope":"ERECTION OF ONE INTERNALLHY ILLUMINATED FLAT WALL SIGN ( 28\"X20'-1-1/2\") ON SPACE 9, SIZE & LOCATION AS SHOWN IN THE APPLICATION. EXISTIN TREATMENT OF PATIENTS WITH RETAIL SALE OF EYE GLASSES AS PREVIOUSLY APPROVED AS PART OF AN EXISTING SHOPPING CENTER WITH USES AS PREVIOUSLY APPROVED."},{"number":"424568","date":"2012-08-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"RELOCATE HEADS TO FIT NEW WALL AND CEILING LAYOUT"},{"number":"425368","date":"2012-09-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-12","scope":"INSTALL 400 AMP SERVICE. SEE 413303 FOR DETAILS."},{"number":"421480","date":"2012-09-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-09-26","scope":"INSTALLATION OF POWER FOR RECEPTACLES INSTALLATION OF LIGHTS INSTALLATION OF LOW VOLTAGE CAT 5 CABLE FOR PHONE/DATA SYSTEM PER 2008 NEC (SHOPPING CTR)"},{"number":"424934","date":"2012-09-11","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2012-09-26","scope":"INSTALL ONE SET 28\" X 20' 1 1/2\" ILLUM LETTERS ON RACEWAYS. (47.74 SQ. FT.) CONNECT TO EXISTING ELECTRIC"},{"number":"424339","date":"2012-09-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"MECHANCIAL DEMO AND ALTERATIONS TO EXISTING SYSTEM, FURNISH AND INSTALL WARM AIR DUCTWORK AND DIFFUSERS,ACCESSORY MECHANICALS FOR ALTERATIONS TO RETAIL SPACE. COMPLY ISSUED VIOLATION"},{"number":"427394","date":"2012-09-17","work":"Zoning","type":"ZP_ZONING","description":"ZONING PERMIT","status":"COMPLETED","completedDate":"2012-09-17","scope":"FOR THE ERECTION OF TWO CONCRETE MASONRY UNIT WALLS ((6 FT HEIGHT);(4 FT HEIGHT)) TO CONNECT TO AN EXISTING WALL AND FOR THE ERECTION OF ONE BOLLARD WITH FOUR EXISTING BOLLARDS TO REMAIN FOR THE PROTECTION OF A PROPOSED PECO TRANSFORMER. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLAN"},{"number":"425332","date":"2012-09-17","work":"Addition","type":"BP_ADDITON","description":"ADDITION PERMIT","status":"COMPLETED","completedDate":"2012-09-26","scope":"FOR THE INSTALLATION OF A SUBSURFACE TRANSFORMER VAULT WITH THE ERECTION OF TWO CONCRETE MASONRY UNIT WALLS ((SIX (6) FT HEIGHT); (FOUR (4) FT HEIGHT)) TO CONNECT TO EXISTING WALL AND ONE BOLLARD W/ FOUR EXISTING BOLLARDS TO REMAIN FOR THE PROTECTION OF THE PROPOSED TRANSFORMER. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLAN. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK."},{"number":"427143","date":"2012-09-19","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"AMENDING PERMIT # 409609 TO CHANGE SPACE # 7 ON ADDRESS TO SPACE # 9"},{"number":"423172","date":"2012-09-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-09-21","scope":"SPACE #7 - INTERIOR ALTERATIONS (PLUMBING) - TENANT FIT-OUT - (4)SINKS, (1)LAVATORY, (1)MOP RECEPTOR AND (2)FLOOR DRAINS - NOTE: PERMIT WAS AMENDED TO SHOW THE CORRECT CONTRACTOR INFORMATION ON 09/20/2012 - LICENSE HOLDER REMAINS THE SAME"},{"number":"431666","date":"2012-10-09","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-10-10","scope":"REPLACE HOUSE TRAP AND FRESH AIR INLET (COMMERCIAL)"},{"number":"435649","date":"2012-11-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-29","scope":"INSTALLATION OF A BURGLAR SYSTEM AS PER 2008 NEC"},{"number":"454981","date":"2013-02-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-09-26","scope":"MAKE SAFE BRICK WALL AS PER ENGINEER'S REPORT"},{"number":"495570","date":"2013-10-10","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2013-10-10","scope":"FOR THE REMOVAL OF AN EXISTING ILLUMINATED FLATWALL SIGN; FOR THE ERECTION OF ONE(1) FLATWALL SIGN AND FOR THE ERECTION OF TWO(2) DOOR SIGNS ( 8'X 6 1/2\") (TOTAL AREA OF DOOR SIGNS PER FLOOR SHALL NOT EXCEED 20% OF THE TOTAL TRANSPARENT GLAZED AREA OF ALL TRANSPARENT GLASS DOORS ON THAT FLOOR). SIZE AND LOCATION AS SHOWN IN THE APPLICATION. (.2) THE AMOUNT OF AREA USED FOR A WINDOW SIGN IS PERMITTED ). SIGN ACCESSORY TO AN EXISTING RETAIL CONSUMER GOODS AND ACCESSORIES ON SPACE # 5 AS PART OF AN EXISTING AREA SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APPROVED."},{"number":"503571","date":"2013-11-08","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2014-01-16","scope":"REMOVAL OF EXISTING ILLUMINATED LETTERS AS PER PLANS. INSTALL ONE SET ILLUMINATED LETTERS."},{"number":"536363","date":"2014-05-13","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2014-05-13","scope":"FOR THE CREATION OF TWO (2) VACANT TENANT SPACES [SUITES 2 & 3] FROM ONE EXISTING TENANT SPACE (USE REGISTRATION PERMITS REQUIERED PRIOR TO OCCUPANCY) AS PART OF AN EXISTING SHOPPING CENTER WITH OTHER USES AS PREVIOUSLY APPROVED. SIZE AND LOCATION AS SHOWN IN APPLICATION."},{"number":"534609","date":"2014-05-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-05-22","scope":"LEVEL II ALTERATIONS TO CREATE TWO (2) TENANT SPACES [SPACES 2 & 3] FROM ONE (1) EXISTING SPACE [SPACE 2] AS PER APPROVED PLANS. SPACES TO BE VACANT, SEPARATE PERMITS REQUIRED FOR FIT-OUTS PRIOR TO OCCUPANCY."},{"number":"523855","date":"2014-05-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-06-09","scope":"INSTALLATION OF BACKFLOW PREVENTER WITH RISER CHECK ON EXISTING SPRINKLER SYSTEM."},{"number":"549272","date":"2014-07-25","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-01-16","scope":"INSTALL 5-FLOOR SINKS, 3-HANDSINKD, 2-COMPARTMENT SINKS, 1-MOP SINK 5-FLOOR DRAINS, 2-LAVS, 2-WC & CAST & COPPER PIPING (COMM)"},{"number":"553973","date":"2014-08-11","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2014-08-11","scope":"FOR THE CHANGE OF USE OF TENANT SPACE #8 TO RETIAL SALES OF CONSUMER GOODS. NO CHANGE IN HEIGHT OR AREA OF STRUCTURE. ALL USES IN OTHER TENANT SPACES AS PREVIOUSLY APPROVED."},{"number":"551275","date":"2014-08-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-09-12","scope":"LEVEL II ALTERATION INCLUDES PARTITION WALL & DRYWALL WHERE NECESSARY, TILE FLOOR PER PLANS"},{"number":"550231","date":"2014-08-27","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-08-27","scope":"FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED WALL SIGN; SIZE & LOCATION AS SHOWN IN APPROVED PLANS. FOR USE AS RETAIL SALE OF CONSUMER GOODS & MAINTENANCE & REPAIR OF CONSUMER GOODS WITHIN AN EXIST. BUILDING W. USES AS PREVIOUSLY APPROVED."},{"number":"558546","date":"2014-08-28","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"INTERIOR DEMOLITION OF 13,000 SF RETAIL SPACE, REMOVAL OF FLOORING, CEILING, LIGHTING, HVAC COMPONENTS, DRYWALL, ETC.(APPLICANT AREES TO EZ PERMIT INTERIOR DEMOLITION STANDARDS)"},{"number":"557433","date":"2014-09-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RELOCATE LIGHTING SWITCHES, INSTALL 3-EXIT COMBO LGTS, 1-EMER WALL PACK, 2-REMOTE HEADS, 5-POWER POLES FOR FL DISPLAY, 8-TRACK LIGHTS, 10-OUTLETS 20AMP TAMPER PROOF AS PER NEC 2008 (MIXED USE) NO F/A ON THIS PERMIT"},{"number":"557058","date":"2014-09-12","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2014-09-22","scope":"FOR THE INSTALLATION OF ONE SET OF 18\"X14\"1 ILLUMINATED CHANNEL LETTERS ON RACEWAY. ONE VINYL WINDOW SIGN. SEPARATE ELECTRIC PERMIT REQUIRED."},{"number":"538512","date":"2014-10-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-01-21","scope":"INTERIOR ALTERATIONS TO INCLUDE TENANT FIT OUT, NEW ADA RESTROOMS, UPGRADES TO FINISHES, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK"},{"number":"567129","date":"2014-10-16","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2014-10-16","scope":"FOR USE AS AN URGENT CARE MEDICAL SERVICES AND PRIMARY CARE MEDICAL SERVICES IN SPACE #2 OF A STRUCTURE WITH OTHER PREVIOUSLY APPROVED USES. NO SIGNS ASSOCIATED WITH THIS APPLICATION. 6TH DISTRICT 54TH WARD."},{"number":"547255","date":"2014-10-20","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2014-10-20","scope":"FOR A TAKE-OUT RESTAURANT ON SPACE #2 ****CORRECTION TO SPACE # 3**** AS PART OF EXISTING AREA SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION."},{"number":"562929","date":"2014-10-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-04-20","scope":"REPLACE ROOFTOP MECHANICAL UNITS. INCLUDES INCIDENTAL WORK OF CONNECTING TO EXISTING DUCTWORK. NO WORK TO DUCTWORK APPROVED IN THIS PERMIT. PERMIT HOLDER MUST ENSURE ADEQUATE SUPPORT IS PROVIDED AND CERTIFIED BY ENGINEER FOR THE RTU'S. APPROVAL OF THIS PERMIT NOTWITHSTANDING. CODE/MECHANICAL DESIGN PROF: DAVID ALLEY, PE ~APPROVED PLANS"},{"number":"554684","date":"2014-10-30","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2014-10-30","scope":"REGISTER USE AS TAKE-OUT RESTAURANT IN SPACE # 3, INSTALL ONE (1) WALL SIGN AND REPLACE TENANT PANELS IN EXISTING DOUBLE-FACED FREE-STANDING SIGN (NO CHANGE IN SIGN HEIGHT OR AREA)"},{"number":"565963","date":"2014-11-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-04-27","scope":"ELECTRICAL SERVICE IS EXISTING. NEW WIRING TO EQUIPMENT AND LIGHTING AS PER 2008 NEC (EAST DISTRICT)"},{"number":"571172","date":"2014-11-13","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2015-02-27","scope":"FOR THE INSTALLATION ON ONE ACCESSORY ILLUMINATED FLAT WALL SIGN AND REPLACEMENT OF TWO TENANT PANELS IN A EXISTING DOUBLE FACED FREE-STANDING SIGN PER SUBMITTED PLAN. SEPARATE ELECTRIC PERMIT REQURIED."},{"number":"571843","date":"2014-12-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-01-16","scope":"INSTALL COMMERCIAL KITCHEN HOOD, DUCTWORK AND FANS, FOR ANSUL SEE AP571846"},{"number":"571846","date":"2014-12-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-01-16","scope":"INTALL ANSUL R102 6.0 GALLON WET CHEMICAL COMMERCIAL KITCHEN FIRE SUPRESSION SYSTEM FOR HOOD SEE AP571843"},{"number":"583494","date":"2015-01-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-05-05","scope":"REPLACE AND INSTALLED CELING SPEAKER,1 MUSIC RACK AND 3 MICS PER 2008 NEC (SHOPPING CENTER)"},{"number":"584443","date":"2015-01-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-04-20","scope":"FOR INTERIOR ALTERATIONS INCLUDING CONSTRUCTION OF NON-LOAD BEARING PARTITIONS TO CREATE EXAM ROOMS, NURSE ROOMS, ACCESSIBLE TOILET ROOMS AS PER APPROVED PLANS."},{"number":"586924","date":"2015-01-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-04-20","scope":"INSTALL 3WC,3LAV,1MS,8SINKS,1KS AND 1EWC-THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"586224","date":"2015-01-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-06","scope":"FOR MECHANICAL ALTERATIONS TO INCLUDE NEW REGISTERS/DIFFUSERS AND ASSOCIATED DUCT WORK AS PER APPROVED PLANS."},{"number":"589431","date":"2015-02-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-04-10","scope":"WE WILL BE RELOCATING 49 SPRINKLERS IN THE TEMPLE COTTMAN READY CARE. 1ST FLOOR"},{"number":"588435","date":"2015-02-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-04","scope":"F&I 2 NEW PANELS,50 SWITCHES/SENSORS,100 RECEPTACLES AND 110 LIGHT FIXTURES PER 2008 NEC (HEALTH CARE FACILITY)"},{"number":"601043","date":"2015-04-23","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2015-04-23","scope":"FOR THE ERECTION OF ONE(1) FLATWALL SIGN ACCESSORY TO EXISTING GROUP PRACTITIONER ( URGENT CARE MEDICAL SERVICES AND PRIMARY CARE MEDICAL SERVICES) IN SPACE #2 ON THE SAME LOT WITH ALL OTHER USES AS PREVIOUSLY APPROVED."},{"number":"605616","date":"2015-05-22","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2015-07-16","scope":"INSTALL INTERNALLY ILLUMINATED SIGN. REFACE FREESTANDING SIGN."},{"number":"893164","date":"2018-08-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-01-07","scope":"FOR LEVEL II ALTERATIONS (WITHOUT A CHANGE OF OCCUPANCY), FOR FIT-OUT OF A GROUP B TENANT (BANK @ SPACE #6, FORMERLY CALLED SPACE #5, PREVIOUSLY ISSUED CO UNDER AP#79629), WITHIN AN EXISTING SINGLE-STORY DETACHED STRUCTURE, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING IS FULLY SPRINKLERED THROUGHOUT IN ACCORDANCE WITH NFPA 13; NO CHANGE TO TENANT SPACE DIMENSIONS; NO SIGNS ON THIS PERMIT."},{"number":"898738","date":"2018-08-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-20","scope":"FOR ALTERATIONS TO AN EXISTING MECHANICAL SYSTEM WITHIN GROUP B TENANT AT SPACE #6 WITHIN AN EXISTING SINGLE-STORY DETACHED STRUCTURE, AS PER PLANS; SEE AP#893164 FOR BUILDING PERMIT; NO OTHER WORK ON THIS PERMIT."},{"number":"895340","date":"2018-08-08","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2018-08-08","scope":"INSTALLATION OF ACCESSORY SIGNAGE FOR FINANCIAL SERVICES TENANT SPACE."},{"number":"895341","date":"2018-08-08","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2018-12-11","scope":"INSTALLATION OF ACCESSORY SIGNAGE AS SHOWN ON PLANS."},{"number":"904575","date":"2018-08-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-11-21","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"908503","date":"2018-09-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-11-20","scope":"REPLACE 2 WC,2 LAVS,1 DF AND ADD KITCHEN SINK (BANK) THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"904532","date":"2018-09-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-12-11","scope":"REUSE EXISTING SERVICE AND PANEL,111 LIGHT FIXTURES,10 EXIT LIGHTS,(1)1000WATT INVETER FOR EMERGENCY LIGHTS,23 SWITCHES,55 RECEPTACLES,5 FLOOR BOXES AND POWER TO 6 HVAC UNITS PER 2008 NEC (BANK)"},{"number":"909334","date":"2018-09-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-20","scope":"HVAC UNIT REPLACEMENT-ROOFTOP UNIT LIKE FOR LIKE 2X SYSTEMS.FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"908679","date":"2018-09-21","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-11-20","scope":"FOR AN AMENDMENT TO PREVIOUSLY ISSUED ALTERATIONS PERMIT AP#893164 TO INCLUDE FRAMING FOR AN ADDITIONAL ATM, INSTALL GUARD RAILS AROUND ROOF HATCH, AND OTHER RELATED CHANGES, AS PER REVISED PLANS; NO OTHER CHANGES ON THIS PERMIT."},{"number":"907769","date":"2018-10-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-02-11","scope":"INSTALL LOW VOLTAGE 50-PLENUM RATED CAT6 4 PAIR 24AWG CABLES FOR VOICE AND DATA WITH A LONGEST RUN OF ABAOUT 150FT.,ALL CABLES WILL BE SUPPORTED WITH J HOOKS AND CABLE TRAY,ALL FIRE RATED WALLS WILL BE SLEEVED AND FIRE STOPPED AS PER 2008 NEC (EAST DISTRICT)"},{"number":"ZP-2020-003495","date":"2020-07-23","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"FOR THE LEGALIZATION OF THE INSTALLATION OF ONE(1) STATICALLY ILLUMINATED WALL SIGN . SIZE AND LOCATION AS SHOWN IN SCANNED PLAN. SIGN ACCESSORY TO AN EXISTING COMMERCIAL SPACE IN AN EXISTING SHOPPING CENTER."},{"number":"GP-2020-005504","date":"2020-07-30","work":"Sign","type":"General","description":"General Permit","status":"Expired","completedDate":"2023-12-01","scope":"Removal of existing \"Sprint\" sign and Installing a \"T-Mobile\" sign. Channel letters on a aluminum backer. Letters are illuminated will be using existing electric."},{"number":"ZP-2021-000702","date":"2021-02-16","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Completed","completedDate":"2021-07-22","scope":"FOR THE REMOVAL OF ONE ACCESSORY WALL SIGN. FOR THE ERECTION OF A STATICALLY ILLUMINATED ACCESSORY WALL SIGN. SIZE AND LOCATION AS SHOWN ON PLANS."},{"number":"GP-2021-001484","date":"2021-04-12","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2021-07-22","scope":"FOR THE REMOVAL OF ONE ACCESSORY WALL SIGN AND FOR THE ERECTION OF A STATICALLY ILLUMINATED ACCESSORY WALL SIGN AS PART OF AN EXISITING 1-STORY ATTACHED SPACE. SIZE AND LOCATION AS SHOWN ON PLANS."},{"number":"EP-2021-004523","date":"2021-06-07","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-08-19","scope":"Install 48 Cat5e cables as per 2017 nec"},{"number":"EP-2021-005103","date":"2021-06-23","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-10-04","scope":"Install a new Honeywell VISTA-20 BA system consisting of head end control panel, motion sensors, doors contacts, glass breaks, wireless panic/hold up buttons, and cell communicator. A new VERINT Video management system shall also be installed that consists of a Video Recorder, POE Switch, Dome Cameras, 360 Cameras, and a Height Strip camera. Per APPROVED DRAWINGS-2017 NEC."},{"number":"CP-2021-005654","date":"2021-11-30","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-05-19","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING RETAIL PHONE & ACCESSORIES STORE IN AN EXISTING SHOPPING CENTER AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"MP-2021-006271","date":"2021-12-08","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-05-19","scope":"Mechanical / Fuel Gas Permit for combo CP-2021-005654"},{"number":"PP-2021-017834","date":"2021-12-08","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-05-06","scope":"Plumbing Permit (Interior) for combo CP-2021-005654"},{"number":"EP-2021-010952","date":"2021-12-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-05-12","scope":"Electrical Permit for combo CP-2021-005654"},{"number":"FP-2022-000166","date":"2022-01-18","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-05-06","scope":"Relocate 25 sprinklers heads on existing wet system See CP-2021-005654"},{"number":"EP-2022-001013","date":"2022-03-17","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-04-29","scope":"Johnson Controls/Tyco shall install a new Honeywell BA system consisting of head end control panel, motion sensors, doors contacts, cell communicator, and keypad. A new CCTV system shall also be installed consisting of a Video Recorder, POE Switch, Dome Cameras, 360 Cameras, and a Mullion camera as per 2017 NEC. [NOTE: Permit CP-2021-005654 shall rebrand the current Sprint store (which is on the corner and currently open) into a T-MOBILE (4SBD) store.]"},{"number":"EP-2022-009677","date":"2022-10-20","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-01-23","scope":"Furnish and install updated light fixtures to replace lights under the canopy soffit at Bank of America Storefront entrance and at the ATM as per 2017 nec"},{"number":"ZP-2023-004889","date":"2023-05-18","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Completed","completedDate":"2023-08-18","scope":"FOR THE INSTALLATION OF ONE (1) STATICALLY ILLUMINATED WALL SIGN AND FOR THE REFACING OF TWO (2) SIDES OF AN EXISTING FREESTANDING SIGN. SIZE AND LOCATION AS PER APPROVED PLANS. SIGN ACCESSORY TO AN EXISTING COMMERCIAL SPACE IN AN EXISTING SHOPPING CENTER."},{"number":"GP-2023-003958","date":"2023-06-02","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2023-08-04","scope":"FOR THE INSTALLATION OF ONE (1) STATICALLY ILLUMINATED WALL SIGN. SIZE AND LOCATION AS PER APPROVED PLANS. SIGN ACCESSORY TO AN EXISTING COMMERCIAL SPACE IN AN EXISTING SHOPPING CENTER. SEE ZP-2023-004889"},{"number":"PP-2023-006367","date":"2023-06-20","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-06-26","scope":"Replace existing backflow prevention device with a new 3/4\" Watts RP Device"},{"number":"CP-2023-002423","date":"2023-07-12","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-08-18","scope":"FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN USE & OCCUPANCY CLASSIFICATION TO AN EXISTING GROUP M RETAIL BEAUTY SUPPLY STORE (SUITE #4 IN THE EXISTING SHOPPING CENTER). EXISTING BUILDING IS SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK."},{"number":"EP-2023-006297","date":"2023-07-13","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-08-11","scope":"1) Installation of a new 100 amp sub panel including new breakers and connectors. Installation of a new 100 amp SER /MC cable from the main tap box to the service panel. Installation of ground system including ground rod and wire. 2) Installation of a new line 30 amp for the electric water heater. 3) Installation of 2 new lines 20 amps for about 8 new outlets throughout the store. 4) Installation of 4-5 new emergency lights including wire, lights and the breaker. 5) Installation of two 4 feet LED lights . all per 2017 NEC code. Amendment: Changes in the scope of work . Replace the old service panel with a new 200 amp 3 Phase panel 42 spaces with all new breakers. Installation of 2 more additional light fixtures including switches. Installation a new Gfci line . Note: We are not installing an a new 100 amp panel anymore only upgrading the existing one."},{"number":"FP-2023-001660","date":"2023-07-14","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-08-15","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (3) SPRINKLER HEADS AS PER NFPA 13"},{"number":"PP-2023-009558","date":"2023-07-27","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-08-17","scope":"Plumbing Permit (Interior) for combo CP-2023-002423"},{"number":"MP-2023-003080","date":"2023-08-11","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-08-18","scope":"Mechanical / Fuel Gas Permit for combo CP-2023-002423 FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM TO INCLUDE INSTALLATION OF NEW GRILLES / REGISTERS / DIFFUSERS AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK."}],"storyTag":"Improved","storyDelta":null,"timeline":[{"y":2023,"k":"permit","w":"Signs (Accessory / Non-Accessory)"},{"y":2023,"k":"permit","w":"Sign"},{"y":2023,"k":"permit","w":"Alterations"},{"y":2023,"k":"permit","w":"Addition and/or Alteration"},{"y":2023,"k":"permit","w":"Addition and/or Alteration"},{"y":2023,"k":"permit","w":"Addition and/or Alterations"},{"y":2023,"k":"permit","w":"Alterations"},{"y":2023,"k":"permit","w":"Addition and/or Alterations"},{"y":2024,"k":"viol","w":"L&I violation"},{"y":2024,"k":"insp","w":"L&I: 1 failed, 1 passed"},{"y":2026,"k":"viol","w":"L&I violation"},{"y":2026,"k":"insp","w":"L&I: 1 failed, 1 passed"}],"rented":false,"licenses":[{"number":"204795","type":"Food Preparing and Serving","status":"Inactive","businessName":"COUNTRYWIDE DEV LLC","legalName":"COUNTRYWIDE DEV LLC","address":"2118 COTTMAN AVE","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2000-03-01","latestIssueDate":"2000-03-01","expirationDate":"2001-04-30","inactiveDate":null},{"number":"285585","type":"Hazardous Materials","status":"Inactive","businessName":"THE SHERWIN WILLIAMS CO","legalName":"THE SHERWIN WILLIAMS CO","address":"2118 COTTMAN AVE","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2001-11-23","latestIssueDate":"2001-11-23","expirationDate":"2009-06-30","inactiveDate":null},{"number":"280979","type":"Dumpster License - Private Property","status":"Inactive","businessName":"SALLY BEAUTY CO INC","legalName":"SALLY BEAUTY CO INC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2003-10-09","latestIssueDate":"2003-10-09","expirationDate":"2010-07-31","inactiveDate":null},{"number":"332457","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"VALLEY VIDEO ENTERTAINMENT","legalName":"VALLEY VIDEO ENTERTAINMENT","address":"2118 COTTMAN AVE","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2005-08-12","latestIssueDate":"2005-08-12","expirationDate":"2007-04-30","inactiveDate":"2012-12-22"},{"number":"490891","type":"Dumpster License - Private Property","status":"Inactive","businessName":"CTG GROUP LLC","legalName":"CTG GROUP LLC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2010-02-03","latestIssueDate":"2010-02-03","expirationDate":null,"inactiveDate":"2010-02-03"},{"number":"525415","type":"Dumpster License - Private Property","status":"Active","businessName":"SALLY BEAUTY HOLDINGS INC","legalName":"SALLY BEAUTY HOLDINGS INC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2011-02-15","latestIssueDate":"2013-08-03","expirationDate":null,"inactiveDate":null},{"number":"529549","type":"Dumpster License - Private Property","status":"Active","businessName":"SPRINT SPECTRUM LP (ATTEN: KIM PURCELL)","legalName":"SPRINT SPECTRUM LP","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2011-04-05","latestIssueDate":"2013-08-30","expirationDate":null,"inactiveDate":null},{"number":"530042","type":"Dumpster License - Private Property","status":"Inactive","businessName":"T-MOBILE NORTHEAST LLC (PERMITS-NEWPORT 1)","legalName":"T-MOBILE NORTHEAST LLC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2011-04-28","latestIssueDate":"2011-04-28","expirationDate":null,"inactiveDate":null},{"number":"533252","type":"Dumpster License - Private Property","status":"Inactive","businessName":"T-MOBILE NORTHEAST LLC (PERMITS-NEWPORT 1)","legalName":"T-MOBILE NORTHEAST LLC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2011-05-16","latestIssueDate":"2012-08-20","expirationDate":"2013-07-31","inactiveDate":null},{"number":"549181","type":"Dumpster License - Private Property","status":"Active","businessName":"HAGERSTOWN REAL ESTATE LLC","legalName":"HAGERSTOWN REAL ESTATE LLC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2011-11-21","latestIssueDate":"2013-07-27","expirationDate":null,"inactiveDate":null},{"number":"592177","type":"Dumpster License - Private Property","status":"Active","businessName":"VISIONWORKS INC","legalName":"VISIONWORKS INC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2013-05-02","latestIssueDate":"2013-08-31","expirationDate":null,"inactiveDate":null},{"number":"673489","type":"Dumpster License - Private Property","status":"Active","businessName":"GSRH Wings PA, LLC","legalName":"GSRH Wings PA, LLC","address":"2118 COTTMAN AVE","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2015-08-06","latestIssueDate":"2015-08-06","expirationDate":null,"inactiveDate":null},{"number":"673491","type":"Food Preparing and Serving","status":"Expired","businessName":"GSRH Wings PA, LLC","legalName":"GSRH Wings PA, LLC","address":"2118 COTTMAN AVE","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2015-08-06","latestIssueDate":"2023-02-16","expirationDate":"2023-04-30","inactiveDate":null}],"licenseActivity":[{"number":"673489","type":"Dumpster License - Private Property","businessName":"GSRH Wings PA, LLC","legalName":"GSRH Wings PA, LLC","issuedDate":"2015-08-06","latestIssueDate":"2015-08-06","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"673491","type":"Food Preparing and Serving","businessName":"GSRH Wings PA, LLC","legalName":"GSRH Wings PA, LLC","issuedDate":"2015-08-06","latestIssueDate":"2023-02-16","closureDate":"2023-04-30","expirationDate":"2023-04-30","inactiveDate":null,"status":"Expired","statusLabel":"Expired","active":false},{"number":"592177","type":"Dumpster License - Private Property","businessName":"VISIONWORKS INC","legalName":"VISIONWORKS INC","issuedDate":"2013-05-02","latestIssueDate":"2013-08-31","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"549181","type":"Dumpster License - Private Property","businessName":"HAGERSTOWN REAL ESTATE LLC","legalName":"HAGERSTOWN REAL ESTATE LLC","issuedDate":"2011-11-21","latestIssueDate":"2013-07-27","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"533252","type":"Dumpster License - Private Property","businessName":"T-MOBILE NORTHEAST LLC (PERMITS-NEWPORT 1)","legalName":"T-MOBILE NORTHEAST LLC","issuedDate":"2011-04-28","latestIssueDate":"2012-08-20","closureDate":"2013-07-31","expirationDate":"2013-07-31","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"529549","type":"Dumpster License - Private Property","businessName":"SPRINT SPECTRUM LP (ATTEN: KIM PURCELL)","legalName":"SPRINT SPECTRUM LP","issuedDate":"2011-04-05","latestIssueDate":"2013-08-30","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"525415","type":"Dumpster License - Private Property","businessName":"SALLY BEAUTY HOLDINGS INC","legalName":"SALLY BEAUTY HOLDINGS INC","issuedDate":"2011-02-15","latestIssueDate":"2013-08-03","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"490891","type":"Dumpster License - Private Property","businessName":"CTG GROUP LLC","legalName":"CTG GROUP LLC","issuedDate":"2010-02-03","latestIssueDate":"2010-02-03","closureDate":"2010-02-03","expirationDate":null,"inactiveDate":"2010-02-03","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"332457","type":"Food Establishment, Retail Permanent Location","businessName":"VALLEY VIDEO ENTERTAINMENT","legalName":"VALLEY VIDEO ENTERTAINMENT","issuedDate":"2005-08-12","latestIssueDate":"2005-08-12","closureDate":"2012-12-22","expirationDate":"2007-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"280979","type":"Dumpster License - Private Property","businessName":"SALLY BEAUTY CO INC","legalName":"SALLY BEAUTY CO INC","issuedDate":"2003-10-09","latestIssueDate":"2003-10-09","closureDate":"2010-07-31","expirationDate":"2010-07-31","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"285585","type":"Hazardous Materials","businessName":"THE SHERWIN WILLIAMS CO","legalName":"THE SHERWIN WILLIAMS CO","issuedDate":"2001-11-23","latestIssueDate":"2001-11-23","closureDate":"2009-06-30","expirationDate":"2009-06-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"204795","type":"Food Preparing and Serving","businessName":"COUNTRYWIDE DEV LLC","legalName":"COUNTRYWIDE DEV LLC","issuedDate":"2000-03-01","latestIssueDate":"2000-03-01","closureDate":"2001-04-30","expirationDate":"2001-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-24","signals":[{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["8 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"building-certifications","level":"urgent","title":"A life-safety certification is deficient","finding":"Fire Alarm Certification: Deficient; Special Hazards Certification: Certified through May 13, 2027; Sprinkler Certification: Certified through Apr 18, 2025","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Appeal #17020: CLOSED · Granted with conditions; related permit 375038. Use permit #76031: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"1 permit not marked completed: GP-2020-005504 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"28 failed, 20 passed, and 4 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Jun 10, 2026.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Preparing and Serving #204795: Inactive; Hazardous Materials #285585: Inactive; Dumpster License - Private Property #280979: Inactive; Food Establishment, Retail Permanent Location #332457: Inactive since Dec 22, 2012","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as commercial. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 22 historical violations across 16 cases.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}