{"asOf":"2026-07-27T03:35:09.155Z","block":"1600-1699 MARKET ST","blockUrl":"https://philadelphia.blockreport.homes/block/1600-1699-market-st","address":"1650 MARKET ST","parcelNumber":"883031676","source":"https://property.phila.gov/?p=883031676","ownerType":"investor","kind":"offices","isHouse":false,"home":false,"commercial":true,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"DB0","buildingCodeNew":"243","buildingClass":"OFF BLD COM NO GAR MASON","buildingClassNew":"OFFICE BLDNG - High Rise","useLabel":"Offices","owner":"PHILA LIBERTY PLA E LP","coOwner":null,"marketValue":311459300,"landAssessment":62579300,"improvementAssessment":248880000,"livableArea":1464000,"yearBuilt":1986,"lastSale":{"price":10,"date":"2005-08-31T04:00:00Z"},"openViolations":12,"violations":[{"number":"499409","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"499410","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"499411","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"499412","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"499414","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"500509","date":"2007-02-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"500510","date":"2007-02-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"500511","date":"2007-02-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503048","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503049","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503050","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503051","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503053","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503539","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503540","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"503548","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"504667","date":"2007-02-28","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"504706","date":"2007-02-28","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1473114","date":"2009-09-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2296867","date":"2011-11-07","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831751","date":"2013-03-15","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831746","date":"2013-03-15","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831747","date":"2013-03-15","code":"FC-2701.5/1","title":"HAZMAT-LIC REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831748","date":"2013-03-15","code":"FC-406.1/1","title":"FIRE/EVAC PLN-EMPLY TRNG DUTY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831749","date":"2013-03-15","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831750","date":"2013-03-15","code":"FC-906.1/1","title":"FIRE EXTING-INSTALL MAX 75FT","status":"RESOLVE","resolutionDate":null,"resolution":null},{"number":"2831752","date":"2013-03-15","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831745","date":"2013-03-15","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3008943","date":"2013-11-18","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294200","date":"2014-08-14","code":"FC-1027.2/1","title":"EGRESS CLEAR OBSTRUCTION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294199","date":"2014-08-14","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294208","date":"2014-08-14","code":"FC-903.6/1","title":"SPRINKLER HEADS CLEARANCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294207","date":"2014-08-14","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294205","date":"2014-08-14","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4587619","date":"2018-02-13","code":"FC-13-605.6","title":"OPEN JUNCTION BOXES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4587618","date":"2018-02-13","code":"FC-13-605.31","title":"LABELING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4587620","date":"2018-02-13","code":"FC-13-607.4","title":"ELEVATOR KEYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4587621","date":"2018-02-13","code":"FC-13-703.11","title":"FIREBLOCKING/DRAFTSTOPPING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4646729","date":"2018-02-15","code":"FC-13-608","title":"GENERAL REQ.- CITE CODE SECTIO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4646728","date":"2018-02-15","code":"FC-13-2703.5","title":"NFPA 704 SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4646727","date":"2018-02-15","code":"FC-13-2701.5","title":"HAZMAT LICENSE REQUIRED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2020-051941","date":"2020-12-08","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051943","date":"2020-12-08","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051942","date":"2020-12-08","code":"FC-13-605.3.1","title":"LABELING","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051940","date":"2020-12-08","code":"FC-13-703.1.1","title":"FIREBLOCKING/DRAFTSTOPPING","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051939","date":"2020-12-08","code":"FC-13-404.2","title":"FIRE SAFETY/EVACUATION PLAN","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051938","date":"2020-12-08","code":"FC-13-2703.5","title":"NFPA 704 SIGNS","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-008807","date":"2021-02-18","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2021-03-08","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2021-008901","date":"2021-02-19","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2021-03-16","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2022-010684","date":"2022-02-16","code":"FC-13-915.1(A)","title":"FIRE SUPPRESSION CERTIFICATION","status":"COMPLIED","resolutionDate":"2022-04-12","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-010685","date":"2022-02-16","code":"FC-13-604.4","title":"STANDBY POWER SYSTEM TESTED","status":"COMPLIED","resolutionDate":"2022-04-12","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-010680","date":"2022-02-16","code":"FC-13-101","title":"ADMINISTRATION GENERAL","status":"COMPLIED","resolutionDate":"2022-04-12","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-013623","date":"2024-02-29","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"CLOSED","resolutionDate":"2024-03-20","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2024-018481","date":"2024-03-20","code":"F-909.20.2","title":"SMOKE CONTROL SYSTEM RECORDS\n","status":"CLOSED","resolutionDate":"2026-06-02","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2024-018486","date":"2024-03-20","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"COMPLIED","resolutionDate":"2026-06-02","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-018487","date":"2024-03-20","code":"F-1013.6.2","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2026-06-02","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2026-013695","date":"2026-03-11","code":"PM15-108.1","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":"2026-03-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2026-013696","date":"2026-03-11","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":"2026-03-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2026-013697","date":"2026-03-11","code":"PM15-304.1(G)","title":"EXTERIOR WALLS","status":"COMPLIED","resolutionDate":"2026-03-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2026-017288","date":"2026-03-26","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"CLOSED","resolutionDate":"2026-06-02","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2026-038243","date":"2026-06-02","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038218","date":"2026-06-02","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038226","date":"2026-06-02","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038227","date":"2026-06-02","code":"F-1104.3","title":"EXIT SIGN ILLUMINATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038232","date":"2026-06-02","code":"F-1203.4.3","title":"RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038236","date":"2026-06-02","code":"F-904.9","title":"HALON SYSTEMS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038233","date":"2026-06-02","code":"F-701.6.1.5","title":"DAMPER CERTIFICATION REPORT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038237","date":"2026-06-02","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038242","date":"2026-06-02","code":"F-909.20.2","title":"SMOKE CONTROL SYSTEM RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"3340341","date":"2014-09-26","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3453179","date":"2015-01-21","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3755878","date":"2015-10-29","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"102671","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-22","completedDate":"2007-02-22","violations":[{"number":"499409","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"102672","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-22","completedDate":"2007-02-22","violations":[{"number":"499410","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"102673","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-22","completedDate":"2007-02-22","violations":[{"number":"499411","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"102674","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-22","completedDate":"2007-02-22","violations":[{"number":"499412","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"102675","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-22","completedDate":"2007-02-22","violations":[{"number":"499414","date":"2007-02-22","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"102824","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-23","completedDate":"2007-02-23","violations":[{"number":"500509","date":"2007-02-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"102825","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-23","completedDate":"2007-02-23","violations":[{"number":"500510","date":"2007-02-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"102826","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-23","completedDate":"2007-02-23","violations":[{"number":"500511","date":"2007-02-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103177","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503048","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103178","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503049","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103179","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503050","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103180","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503051","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103181","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503053","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103261","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503539","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103263","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503540","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103265","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-27","completedDate":"2007-02-27","violations":[{"number":"503548","date":"2007-02-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103451","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-28","completedDate":"2007-02-28","violations":[{"number":"504667","date":"2007-02-28","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"103455","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-02-28","completedDate":"2007-02-28","violations":[{"number":"504706","date":"2007-02-28","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"215546","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2009-09-25","completedDate":"2009-11-18","violations":[{"number":"1473114","date":"2009-09-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"308193","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-12-05","completedDate":"2011-12-05","violations":[{"number":"2296867","date":"2011-11-07","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"373016","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-03-19","completedDate":"2013-08-13","violations":[{"number":"2831751","date":"2013-03-15","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831746","date":"2013-03-15","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831747","date":"2013-03-15","code":"FC-2701.5/1","title":"HAZMAT-LIC REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831748","date":"2013-03-15","code":"FC-406.1/1","title":"FIRE/EVAC PLN-EMPLY TRNG DUTY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831749","date":"2013-03-15","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831750","date":"2013-03-15","code":"FC-906.1/1","title":"FIRE EXTING-INSTALL MAX 75FT","status":"RESOLVE","resolutionDate":null,"resolution":null},{"number":"2831752","date":"2013-03-15","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2831745","date":"2013-03-15","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"411180","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-11-18","completedDate":"2013-11-18","violations":[{"number":"3008943","date":"2013-11-18","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"448198","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-08-14","completedDate":"2014-09-22","violations":[{"number":"3294200","date":"2014-08-14","code":"FC-1027.2/1","title":"EGRESS CLEAR OBSTRUCTION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294199","date":"2014-08-14","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294208","date":"2014-08-14","code":"FC-903.6/1","title":"SPRINKLER HEADS CLEARANCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294207","date":"2014-08-14","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3294205","date":"2014-08-14","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"621966","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2018-02-13","completedDate":"2018-04-19","violations":[{"number":"4587619","date":"2018-02-13","code":"FC-13-605.6","title":"OPEN JUNCTION BOXES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4587618","date":"2018-02-13","code":"FC-13-605.31","title":"LABELING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4587620","date":"2018-02-13","code":"FC-13-607.4","title":"ELEVATOR KEYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4587621","date":"2018-02-13","code":"FC-13-703.11","title":"FIREBLOCKING/DRAFTSTOPPING","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"622333","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2018-02-15","completedDate":"2018-08-03","violations":[{"number":"4646729","date":"2018-02-15","code":"FC-13-608","title":"GENERAL REQ.- CITE CODE SECTIO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4646728","date":"2018-02-15","code":"FC-13-2703.5","title":"NFPA 704 SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4646727","date":"2018-02-15","code":"FC-13-2701.5","title":"HAZMAT LICENSE REQUIRED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2020-086238","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PROPERTY MAINTENANCE INVESTIGATOR","status":"CLOSED","createdDate":"2020-12-09","completedDate":"2021-01-27","violations":[{"number":"VI-2020-051941","date":"2020-12-08","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051943","date":"2020-12-08","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051942","date":"2020-12-08","code":"FC-13-605.3.1","title":"LABELING","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051940","date":"2020-12-08","code":"FC-13-703.1.1","title":"FIREBLOCKING/DRAFTSTOPPING","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051939","date":"2020-12-08","code":"FC-13-404.2","title":"FIRE SAFETY/EVACUATION PLAN","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2020-051938","date":"2020-12-08","code":"FC-13-2703.5","title":"NFPA 704 SIGNS","status":"COMPLIED","resolutionDate":"2021-01-25","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2021-011528","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"AUDITS AND INVESTIGATIONS BUILDING CERTS","status":"CLOSED","createdDate":"2021-02-18","completedDate":"2021-03-08","violations":[{"number":"VI-2021-008807","date":"2021-02-18","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2021-03-08","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2021-011697","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"AUDITS AND INVESTIGATIONS BUILDING CERTS","status":"CLOSED","createdDate":"2021-02-19","completedDate":"2021-03-16","violations":[{"number":"VI-2021-008901","date":"2021-02-19","code":"PM15-315.2","title":"FACADES","status":"COMPLIED","resolutionDate":"2021-03-16","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2022-012754","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2022-02-16","completedDate":"2022-04-12","violations":[{"number":"VI-2022-010684","date":"2022-02-16","code":"FC-13-915.1(A)","title":"FIRE SUPPRESSION CERTIFICATION","status":"COMPLIED","resolutionDate":"2022-04-12","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-010685","date":"2022-02-16","code":"FC-13-604.4","title":"STANDBY POWER SYSTEM TESTED","status":"COMPLIED","resolutionDate":"2022-04-12","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-010680","date":"2022-02-16","code":"FC-13-101","title":"ADMINISTRATION GENERAL","status":"COMPLIED","resolutionDate":"2022-04-12","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2024-016521","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2024-03-04","completedDate":"2024-03-21","violations":[{"number":"VI-2024-013623","date":"2024-02-29","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"CLOSED","resolutionDate":"2024-03-20","resolution":"CLOSED - REISSUED/REWRITTEN"}]},{"number":"CF-2024-022448","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2024-03-20","completedDate":null,"violations":[{"number":"VI-2024-018481","date":"2024-03-20","code":"F-909.20.2","title":"SMOKE CONTROL SYSTEM RECORDS\n","status":"CLOSED","resolutionDate":"2026-06-02","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2024-018486","date":"2024-03-20","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"COMPLIED","resolutionDate":"2026-06-02","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-018487","date":"2024-03-20","code":"F-1013.6.2","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2026-06-02","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2026-021984","type":"NOTICE OF VIOLATION","priority":"UNSAFE","responsibility":"CSU INVESTIGATOR","status":"CLOSED","createdDate":"2026-03-11","completedDate":"2026-03-27","violations":[{"number":"VI-2026-013695","date":"2026-03-11","code":"PM15-108.1","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":"2026-03-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2026-013696","date":"2026-03-11","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":"2026-03-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2026-013697","date":"2026-03-11","code":"PM15-304.1(G)","title":"EXTERIOR WALLS","status":"COMPLIED","resolutionDate":"2026-03-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2026-028017","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2026-03-26","completedDate":"2026-06-02","violations":[{"number":"VI-2026-017288","date":"2026-03-26","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"CLOSED","resolutionDate":"2026-06-02","resolution":"CLOSED - REISSUED/REWRITTEN"}]},{"number":"CF-2026-062580","type":"NOTICE OF VIOLATION","priority":"ADMINISTRATIVE NOTICE OF VIOLATION","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2026-06-02","completedDate":null,"violations":[{"number":"VI-2026-038243","date":"2026-06-02","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038218","date":"2026-06-02","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038226","date":"2026-06-02","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038227","date":"2026-06-02","code":"F-1104.3","title":"EXIT SIGN ILLUMINATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038232","date":"2026-06-02","code":"F-1203.4.3","title":"RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038236","date":"2026-06-02","code":"F-904.9","title":"HALON SYSTEMS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038233","date":"2026-06-02","code":"F-701.6.1.5","title":"DAMPER CERTIFICATION REPORT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038237","date":"2026-06-02","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2026-038242","date":"2026-06-02","code":"F-909.20.2","title":"SMOKE CONTROL SYSTEM RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"550762","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3340341","date":"2014-09-26","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"575446","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3453179","date":"2015-01-21","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"638461","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3755878","date":"2015-10-29","code":"A-104.1/1","title":"WORKMANLIKE- BUILDING CODE","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2007,"n":18,"worst":null},{"y":2009,"n":1,"worst":null},{"y":2011,"n":1,"worst":null},{"y":2013,"n":9,"worst":null},{"y":2014,"n":6,"worst":null},{"y":2015,"n":2,"worst":null},{"y":2018,"n":7,"worst":null},{"y":2020,"n":6,"worst":null},{"y":2021,"n":2,"worst":null},{"y":2022,"n":3,"worst":null},{"y":2024,"n":4,"worst":null},{"y":2026,"n":13,"worst":"UNSAFE STRUCTURE"}],"investigations":[{"caseNumber":"102671","date":"2007-02-22","type":"BC INSP","status":"PASSED"},{"caseNumber":"102672","date":"2007-02-22","type":"BC INSP","status":"PASSED"},{"caseNumber":"102673","date":"2007-02-22","type":"BC INSP","status":"PASSED"},{"caseNumber":"102674","date":"2007-02-22","type":"BC INSP","status":"PASSED"},{"caseNumber":"102675","date":"2007-02-22","type":"BC INSP","status":"PASSED"},{"caseNumber":"102824","date":"2007-02-23","type":"BC INSP","status":"PASSED"},{"caseNumber":"102825","date":"2007-02-23","type":"BC INSP","status":"PASSED"},{"caseNumber":"102826","date":"2007-02-23","type":"BC INSP","status":"PASSED"},{"caseNumber":"103177","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103178","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103179","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103180","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103181","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103265","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103261","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103263","date":"2007-02-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"103451","date":"2007-02-28","type":"BC INSP","status":"PASSED"},{"caseNumber":"103455","date":"2007-02-28","type":"BC INSP","status":"PASSED"},{"caseNumber":"215546","date":"2009-09-24","type":"BC INSP","status":"FAILED"},{"caseNumber":"215546","date":"2009-11-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"308193","date":"2011-11-08","type":"CI INSP","status":"PASSED"},{"caseNumber":"373016","date":"2013-03-15","type":"CI INSP","status":"FAILED"},{"caseNumber":"373016","date":"2013-06-12","type":"CI INSP","status":"FAILED"},{"caseNumber":"373016","date":"2013-08-08","type":"CI INSP","status":"PASSED"},{"caseNumber":"411180","date":"2013-11-18","type":"CI INSP","status":"PASSED"},{"caseNumber":"448198","date":"2014-08-14","type":"CI INSP","status":"FAILED"},{"caseNumber":"448198","date":"2014-09-22","type":"CI INSP","status":"PASSED"},{"caseNumber":"621966","date":"2018-02-13","type":"CI INSP","status":"FAILED"},{"caseNumber":"622333","date":"2018-02-15","type":"CI INSP","status":"FAILED"},{"caseNumber":"621966","date":"2018-04-19","type":"CI INSP","status":"PASSED"},{"caseNumber":"622333","date":"2018-04-19","type":"CI INSP","status":"FAILED"},{"caseNumber":"622333","date":"2018-05-04","type":"CI INSP","status":"PASSED"},{"caseNumber":"CF-2020-086238","date":"2020-12-09","type":null,"status":"FAILED"},{"caseNumber":"CF-2020-086238","date":"2021-01-27","type":null,"status":"PASSED"},{"caseNumber":"CF-2021-011528","date":"2021-02-18","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-011697","date":"2021-02-19","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-011528","date":"2021-03-08","type":null,"status":"PASSED"},{"caseNumber":"CF-2021-011697","date":"2021-03-16","type":null,"status":"PASSED"},{"caseNumber":"CF-2022-012754","date":"2022-02-16","type":null,"status":"FAILED"},{"caseNumber":"CF-2022-012754","date":"2022-03-28","type":null,"status":"FAILED"},{"caseNumber":"CF-2022-012754","date":"2022-04-12","type":null,"status":"PASSED"},{"caseNumber":"CF-2024-016521","date":"2024-03-04","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-022448","date":"2024-03-21","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-016521","date":"2024-03-21","type":null,"status":"PASSED"},{"caseNumber":"CF-2026-021984","date":"2026-03-11","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-028017","date":"2026-03-26","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-021984","date":"2026-03-27","type":null,"status":"PASSED"},{"caseNumber":"CF-2026-028017","date":"2026-06-02","type":null,"status":"PASSED"},{"caseNumber":"CF-2026-062580","date":"2026-06-02","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-062580","date":"2026-06-03","type":null,"status":"FAILED"}],"inspYears":[{"y":2007,"fails":0,"passes":18},{"y":2009,"fails":1,"passes":1},{"y":2011,"fails":0,"passes":1},{"y":2013,"fails":2,"passes":2},{"y":2014,"fails":1,"passes":1},{"y":2018,"fails":3,"passes":2},{"y":2020,"fails":1,"passes":0},{"y":2021,"fails":2,"passes":3},{"y":2022,"fails":2,"passes":1},{"y":2024,"fails":2,"passes":1},{"y":2026,"fails":4,"passes":2}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.95256026943934,"lng":-75.16808522018142,"geom":{"type":"Polygon","coordinates":[[[-75.167787323,39.952281016],[-75.168482517,39.952365397],[-75.16838156,39.952840062],[-75.167688939,39.952755093],[-75.167787323,39.952281016]]]},"liDistrict":"CENTRAL WEST","certifications":[{"number":"BC-2022-011716","type":"Facade Report","inspectionDate":"2013-08-12","result":"Safe with Repair","expirationDate":"2018-08-12","buildingId":"1519722"},{"number":"BC-2022-008406","type":"Facade Report","inspectionDate":"2014-05-31","result":"Safe with Repair","expirationDate":"2019-05-31","buildingId":"1519722"},{"number":"BC-2022-004075","type":"Facade Report","inspectionDate":"2017-05-31","result":"Safe with Repair","expirationDate":"2022-05-31","buildingId":"1519722"},{"number":"BC-2020-000647","type":"Fire Alarm Certification","inspectionDate":"2020-10-07","result":"Certified","expirationDate":"2021-10-07","buildingId":"1519722"},{"number":"BC-2022-004776","type":"Sprinkler Certification","inspectionDate":"2020-12-10","result":"Certified","expirationDate":"2021-12-10","buildingId":"1519722"},{"number":"BC-2022-001340","type":"Damper Certification","inspectionDate":"2021-09-30","result":"Certified","expirationDate":"2025-09-30","buildingId":"1519722"},{"number":"BC-2022-001341","type":"Smoke Control Certification","inspectionDate":"2021-10-04","result":"Certified","expirationDate":"2022-10-04","buildingId":"1519722"},{"number":"BC-2024-015438","type":"Special Hazards Certification","inspectionDate":"2022-01-28","result":"Certified","expirationDate":"2023-01-28","buildingId":"1519722"},{"number":"BC-2022-004775","type":"Sprinkler Certification","inspectionDate":"2022-03-18","result":"Certified","expirationDate":"2023-03-18","buildingId":"1519722"},{"number":"BC-2022-006270","type":"Sprinkler Certification","inspectionDate":"2022-04-29","result":"Certified","expirationDate":"2023-04-29","buildingId":"1519722"},{"number":"BC-2022-006160","type":"Special Hazards Certification","inspectionDate":"2022-04-29","result":"Certified","expirationDate":"2023-04-29","buildingId":"1519722"},{"number":"BC-2022-008315","type":"Sprinkler Certification","inspectionDate":"2022-05-02","result":"Certified","expirationDate":"2023-05-02","buildingId":"1519722"},{"number":"BC-2022-008316","type":"Sprinkler Certification","inspectionDate":"2022-05-02","result":"Certified","expirationDate":"2023-05-02","buildingId":"1519722"},{"number":"BC-2023-015842","type":"Fire Alarm Certification","inspectionDate":"2022-09-10","result":"Certified","expirationDate":"2023-09-10","buildingId":"1519722"},{"number":"BC-2023-013162","type":"Sprinkler Certification","inspectionDate":"2023-05-23","result":"Certified","expirationDate":"2024-05-23","buildingId":"1519722"},{"number":"BC-2023-016057","type":"Special Hazards Certification","inspectionDate":"2023-08-02","result":"Certified","expirationDate":"2024-08-02","buildingId":"1519722"},{"number":"BC-2024-007126","type":"Special Hazards Certification","inspectionDate":"2023-09-26","result":"Certified","expirationDate":"2024-09-26","buildingId":"1519722"},{"number":"BC-2024-007129","type":"Special Hazards Certification","inspectionDate":"2023-09-26","result":"Certified","expirationDate":"2024-09-26","buildingId":"1519722"},{"number":"BC-2023-022083","type":"Fire Alarm Certification","inspectionDate":"2023-10-30","result":"Certified","expirationDate":"2024-10-30","buildingId":"1519722"},{"number":"BC-2023-023833","type":"Special Hazards Certification","inspectionDate":"2023-11-10","result":"Certified","expirationDate":"2024-11-10","buildingId":"1519722"},{"number":"BC-2023-023733","type":"Emergency and Standby Power Systems Certification","inspectionDate":"2023-11-18","result":"Certified","expirationDate":"2024-11-18","buildingId":"1519722"},{"number":"BC-2024-000505","type":"Special Hazards Certification","inspectionDate":"2023-12-08","result":"Certified","expirationDate":"2024-12-08","buildingId":"1519722"},{"number":"BC-2024-011233","type":"Special Hazards Certification","inspectionDate":"2024-03-22","result":"Certified","expirationDate":"2025-03-22","buildingId":"1519722"},{"number":"BC-2024-016097","type":"Sprinkler Certification","inspectionDate":"2024-04-07","result":"Certified","expirationDate":"2025-04-07","buildingId":"1519722"},{"number":"BC-2024-019161","type":"Facade Report","inspectionDate":"2024-04-25","result":"Safe with Repair","expirationDate":"2029-04-25","buildingId":"1519722"},{"number":"BC-2024-012297","type":"Smoke Control Certification","inspectionDate":"2024-04-29","result":"Certified","expirationDate":"2025-04-29","buildingId":"1519722"},{"number":"BC-2024-015452","type":"Special Hazards Certification","inspectionDate":"2024-05-07","result":"Certified","expirationDate":"2025-05-07","buildingId":"1519722"},{"number":"BC-2024-015447","type":"Special Hazards Certification","inspectionDate":"2024-05-07","result":"Certified","expirationDate":"2025-05-07","buildingId":"1519722"},{"number":"BC-2024-027377","type":"Fire Alarm Certification","inspectionDate":"2024-09-14","result":"Certified","expirationDate":"2025-09-14","buildingId":"1519722"},{"number":"BC-2024-029466","type":"Special Hazards Certification","inspectionDate":"2024-10-28","result":"Certified","expirationDate":"2025-10-28","buildingId":"1519722"},{"number":"BC-2025-000735","type":"Special Hazards Certification","inspectionDate":"2024-12-18","result":"Certified","expirationDate":"2025-12-18","buildingId":"1519722"},{"number":"BC-2025-002952","type":"Fire Alarm Certification","inspectionDate":"2025-02-03","result":"Certified","expirationDate":"2026-02-03","buildingId":"1519722"},{"number":"BC-2025-015552","type":"Special Hazards Certification","inspectionDate":"2025-05-19","result":"Certified","expirationDate":"2026-05-19","buildingId":"1519722"},{"number":"BC-2025-017709","type":"Special Hazards Certification","inspectionDate":"2025-07-01","result":"Certified","expirationDate":"2026-07-01","buildingId":"1519722"},{"number":"BC-2025-017711","type":"Special Hazards Certification","inspectionDate":"2025-07-01","result":"Certified","expirationDate":"2026-07-01","buildingId":"1519722"},{"number":"BC-2025-027399","type":"Special Hazards Certification","inspectionDate":"2025-10-16","result":"Certified","expirationDate":"2026-10-16","buildingId":"1519722"},{"number":"BC-2025-029066","type":"Fire Alarm Certification","inspectionDate":"2025-10-30","result":"Certified","expirationDate":"2026-10-30","buildingId":"1519722"},{"number":"BC-2026-017813","type":"Emergency and Standby Power Systems Certification","inspectionDate":"2025-11-15","result":"Certified","expirationDate":"2026-11-15","buildingId":"1519722"},{"number":"BC-2026-016351","type":"Sprinkler Certification","inspectionDate":"2025-12-15","result":"Certified","expirationDate":"2026-12-15","buildingId":"1519722"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19103","beds":null,"baths":null,"stories":61,"lotArea":32876,"zoning":"CMX5","grade":"C","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"1650 MARKET ST, PHILADELPHIA PA, 19103","mailOut":false,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR AN EAT IN ONLY RESTAURANT WITH SEATING FOR THIRTY (30) PERSONS ON THE ENTIRE 37TH. FLOOR FOR AN EXISTING BUILDING WITH 130 APARTMENTS AND PREVIOUSLY APPROVED USES.","status":"OPEN","outcome":"Granted","date":"2008-12-17","number":"1718","relatedPermit":null},{"type":"BBS Permit Denial","grounds":"Selective demolition and interior fitout of 3 floors (38-40) for business use in 1650 Market St. including a new 3 level communicating stair.","status":"Completed","outcome":"Approved","date":"2024-02-19","number":"PA-2023-006902","relatedPermit":null}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":207713500,"taxable":207713500,"land":9862800,"improvement":197850700,"taxableLand":9862800,"taxableImprovement":197850700,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":207713500,"taxable":207713500,"land":9862800,"improvement":197850700,"taxableLand":9862800,"taxableImprovement":197850700,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":289192200,"taxable":289192200,"land":58053640,"improvement":231138560,"taxableLand":58053640,"taxableImprovement":231138560,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":325830200,"taxable":325830200,"land":49118675,"improvement":276711525,"taxableLand":49118675,"taxableImprovement":276711525,"exemptLand":0,"exemptImprovement":0},{"y":2020,"v":327016600,"taxable":327016600,"land":49289830,"improvement":277726770,"taxableLand":49289830,"taxableImprovement":277726770,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":327016600,"taxable":327016600,"land":49289830,"improvement":277726770,"taxableLand":49289830,"taxableImprovement":277726770,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":327016600,"taxable":327016600,"land":49289830,"improvement":277726770,"taxableLand":49289830,"taxableImprovement":277726770,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":335295000,"taxable":335295000,"land":67307560,"improvement":267987440,"taxableLand":67307560,"taxableImprovement":267987440,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":335295000,"taxable":335295000,"land":67307560,"improvement":267987440,"taxableLand":67307560,"taxableImprovement":267987440,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":310683700,"taxable":310683700,"land":62400420,"improvement":248283280,"taxableLand":62400420,"taxableImprovement":248283280,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":310683700,"taxable":310683700,"land":62400420,"improvement":248283280,"taxableLand":62400420,"taxableImprovement":248283280,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":311459300,"taxable":311459300,"land":62579300,"improvement":248880000,"taxableLand":62579300,"taxableImprovement":248880000,"exemptLand":0,"exemptImprovement":0}],"taxNow":4348950,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"48133","date":"2007-01-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-30","scope":"FLOORS 4,5,6,7,8,9,10,11,12,14,15, REPLACE EXISTING HALL CEILING LIGHTS WITH NEW (120 FIXTURES) (ONLY), REPLACE EXISTING WALL SCONCES LIGHTS WITH NEW (220 FIXTURES), REPLACE EXISTING BATHROOM LIGHTS WITH NEW (350 FIXTURES), REPLACE EXISTING WALL PLATES ON EXISTING DEVICES (5000 PLATES).(ONLY REPLACEMENT ONLY)!"},{"number":"47816","date":"2007-01-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-04-02","scope":"HVAC INCLUDING DUCTWORK AS PER PLANS."},{"number":"49067","date":"2007-01-10","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-04-02","scope":"INTERIOR DEMOLITION, 43RD FLOOR"},{"number":"49458","date":"2007-01-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-07-26","scope":"(O) SK (2) FX"},{"number":"50415","date":"2007-01-17","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-04-02","scope":"INTERIOR NON-BEARING DEMOLITION, 42ND FLOOR"},{"number":"50637","date":"2007-01-18","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-04-02","scope":"INTERIOR NON-BEARING DEMOLITION - 3RD FLOOR, MANAGEMENT OFFICE"},{"number":"51889","date":"2007-01-24","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":null,"scope":"(O) SK (1) FX"},{"number":"47622","date":"2007-01-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-13","scope":"RENOVATIONS TO EXISTING OFFICE SPACE. NO CHANGE IN LOADS, FIRE ALARM EXISTING AND WILL REMAIN OR RELOCATED. THE COMMUNICATION WIRING WILL BE DONE WITH PLENUM WIRING"},{"number":"48121","date":"2007-02-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL NEW LIGHT FIXTURES ON 3RD FLOOR, CONVERT NINE (9) GUEST ROOM BATHROOMS TO ADA. REWIRE 15TH FLOOR SIX (6) SUITES."},{"number":"55353","date":"2007-02-08","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-04-30","scope":"DEMOLITION OF NON-BEARING PARTITIONS"},{"number":"55349","date":"2007-02-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-06-11","scope":"TENANT FIT-OUT AS PER PLANS"},{"number":"57785","date":"2007-02-22","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-04-02","scope":"REMOVAL OF EXISTING NON-EGRESS COMMUNICATION STAIR BETWEEN VACANT 41ST AND 42ND FLOORS PRIOR TO IN-FILL UNDER SEPARATE PERMIT. 42\" GUARD RAIL TO BE PLACED AROUND OPENING PRIOR TO AND DURING STAIR REMOVAL AND FUTURE IN-FILL OPERATIONS"},{"number":"58477","date":"2007-02-26","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-05-08","scope":null},{"number":"56872","date":"2007-02-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-04-03","scope":"REMOVAL OF EXISTING NON-EGRESS COMMUNICATION STAIR AND INFILL OF OPENING WITH 42ND FL. AS PER PLANS"},{"number":"59001","date":"2007-02-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-07-23","scope":"RELOCATE 6 DIFFUSERS/REGISTERS (42ND & 43RD FLOORS - TOILET ROOMS)"},{"number":"58520","date":"2007-03-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-07-23","scope":"INTERIOR ALTERATION AS PER PLAN"},{"number":"59950","date":"2007-03-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"INTERIOR ALTERATIONS AS PER PLAN."},{"number":"60478","date":"2007-03-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":null,"scope":"(O) WC LAV (4) FX"},{"number":"60592","date":"2007-03-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-05-23","scope":"INTERIOR ALTERATIONS: FITOUT OF OFFICE SPACE ON 29TH FLOOR"},{"number":"63956","date":"2007-03-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-08","scope":"4 - 2X2 LIGHTS, 2 SWITCHES, 4 GFI RECEPTS, ADA BATHROOMS (CENTER CITY DISTRICT)"},{"number":"66038","date":"2007-04-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-11-13","scope":"RELOCATE 18 DIFFUSERS"},{"number":"66945","date":"2007-04-05","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-04-30","scope":"INTERIOR DEMO NON BEARING WALLS"},{"number":"67616","date":"2007-04-10","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"66859","date":"2007-04-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"INTERIOR ALTERATIONS, AS PER PLAN"},{"number":"68329","date":"2007-04-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":null,"scope":"(O) SK (1) FX"},{"number":"69437","date":"2007-04-16","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"66943","date":"2007-04-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-08-06","scope":"INTERIOR CONSTRUCTION"},{"number":"70001","date":"2007-04-18","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-05-08","scope":"INTERIOR NON-BEARING DEMOLITION - 50TH FLOOR"},{"number":"68042","date":"2007-04-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-07-05","scope":"INTERIOR ALTERATIONS TO 28TH FLOOR OFFICE SPACE-SINGLE TENANT FLOOR"},{"number":"70279","date":"2007-04-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-06-28","scope":"TENNANT FIT AS PER PLANS NO STRUCTURAL WORK ON THIS PERMIT"},{"number":"73228","date":"2007-05-03","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"73291","date":"2007-05-03","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-06-28","scope":null},{"number":"73397","date":"2007-05-03","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-07-05","scope":null},{"number":"71513","date":"2007-05-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-11-13","scope":"HVAC INCLUDING DUCTWORK 6TH FLOOR PARTIAL TENANT AREA, ALL WORK SHALL CONFORM TO THE APPROVED PLANS."},{"number":"72838","date":"2007-05-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-30","scope":"ADD (30) STROBE LIGHTS TO ADA BATHROOMS. DRAWINGS SHOW 120V SMOKE DETS (PREVIOUSLY INSTALLED UNDER PERMIT 48133) (CC DIST)"},{"number":"70760","date":"2007-05-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-06-28","scope":"ALTERATIONS TO HVAC AS PER SUBMITTED SEALED PLANS. (13 NEW DIFFUSERS & 13 RELOCATIONS.)"},{"number":"61631","date":"2007-05-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-09-28","scope":"INTERIOR ALTERATIONS (TENANT FIT-UP) FOR OFFICE SPACE ON THE 42ND AND 43RD FLOORS"},{"number":"77712","date":"2007-05-21","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-09-28","scope":null},{"number":"77810","date":"2007-05-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-07-26","scope":"(O) SK"},{"number":"76954","date":"2007-05-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-06-28","scope":"TENANT FIT-OUT"},{"number":"79720","date":"2007-05-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLING 1 DISHWASHER, (1) 3\" FLOOR DRAIN W/TRAP PRIMER, 8 KS, ALL FOR COFFEE STATION, 3\" SANITARY LINE FOR DRAIN AND VENT FOR FLOOR DRAIN, 2\" SANITARY DRAIN FOR SINK, HOT AND COLD WATER."},{"number":"71300","date":"2007-05-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"PROVIDE & INSTALL VOICE/DATA CABLES & MAKE TERMINATIONS."},{"number":"80558","date":"2007-06-04","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-11-13","scope":"INTERIOR NON-BEARING DEMOLITION (50TH FLOOR)"},{"number":"71683","date":"2007-06-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-04-18","scope":"36 DUPL RECEPTS, 3 QUAD RECEPTS, 10 FURN FEEDS, 18 MOTION SENSORS. REMOVE AND RELOCATE 32 FXTS & ADD 16 NEWE 2X4'S, 37 DOWNLIGHTS. (CC DIST)"},{"number":"79594","date":"2007-06-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-10-16","scope":"INTERIOR ALTERATIONS AS PER PLANS"},{"number":"72023","date":"2007-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"VOICE/DATA CABLING TO 54 STATIONS, LONGEST CAT5E RUN - 220' (CC DIST)"},{"number":"55908","date":"2007-06-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-09-12","scope":"INSTALL (30) SPEAKERS ABOVE DROP CEILING, 1/2 CABLE IN A DAISY CHAIN CONFIGURATION"},{"number":"81247","date":"2007-06-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-09-28","scope":"HVAC & DUCTWORK AS SHOWN ON PLANS. 332 NEW OPENINGS"},{"number":"72634","date":"2007-06-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-02","scope":"RENOVATION TO EXISTING OFFICE SPACE. ALL ELECTRICAL PANELS ANRE EXISTINGM, FIRE ALARM WILL BE REINSTALLED AND TESTED, NO ADDITIONAL LOAKDS AND ON TELEPHONE AND DATA WIRING(CC DIST)"},{"number":"82564","date":"2007-06-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-07-30","scope":"INSTALL FIXTURE"},{"number":"84321","date":"2007-06-19","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"74364","date":"2007-06-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-07-14","scope":"FURNISH & INSTALL (51) CAT 6 LOCATIONS PLENUM CABLE (CC DIST)"},{"number":"85146","date":"2007-06-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-06-05","scope":"FIXTURE INSTALLATION"},{"number":"70490","date":"2007-06-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-15","scope":"HVAC / DUCTWORK PER PLAN \"CITI GROUP\" TENANT SPACE 35TH FLOOR"},{"number":"70488","date":"2007-06-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-08-15","scope":"INTERIOR ALTERATIONS PER PLAN \"CITI GROUP\" TENANT SPACE 35TH FLOOR"},{"number":"85787","date":"2007-06-26","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-10-16","scope":null},{"number":"85798","date":"2007-06-26","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":null},{"number":"80046","date":"2007-06-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"REFURBISH 46TH FLR. FOR LAW OFFICES"},{"number":"86602","date":"2007-06-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-01-29","scope":"FIXTURE INSTALLATION"},{"number":"85885","date":"2007-07-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-10-16","scope":"HVAC,INCLUDING DUCTWORK PER PLANS"},{"number":"87020","date":"2007-07-02","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"86485","date":"2007-07-03","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-08-06","scope":null},{"number":"82429","date":"2007-07-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-07","scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT. INSTALL 169 LIGHT FIXTURES, 20 WALL SWITCHES, 1 LIGHTING CONTACTOR, 79 RECEPTS, 2 EXHAUST FAN FEEDS, 5 HVAC FEEDS, 1 - 480 VOLT PANEL, 1 - 208/120 V PANEL, 1 REWIRE EXISTING 30KVA TRANSFORMER (CC DIST)"},{"number":"69354","date":"2007-07-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-08","scope":"NEW LIGHTING & POWER IN EXISTING OFFICE SPACE. (CC DIST)"},{"number":"74718","date":"2007-07-09","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-03-19","scope":"INSTALL (250-260) CATEGORY 5e CABLES - LONGEST RUN 175' (CC DIST) INSTALL (250-260) CATEGORY 5e CABLES - LONGEST RUN 175' (CC DIST)"},{"number":"86522","date":"2007-07-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-10-16","scope":"INFILLING STAIRWAY"},{"number":"89755","date":"2007-07-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"INSTALL HVAC SYSTEM TO INCLUDE DUCTWORK AS PER PLANS"},{"number":"79560","date":"2007-07-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-26","scope":"POWER AND LIGHTING, SECURITY ANS SPEAKERS. EXCLUDE FIRE ALARMS FLOORS 42 AND 43. (CC DISTRICT)"},{"number":"90192","date":"2007-07-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-26","scope":"TELECOMMUNICATIONS. (CC DIST)"},{"number":"85018","date":"2007-07-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-26","scope":"INSTALL 4 SMOKE DETECTORS, 2 HEAT DETECTORS, 32 SPEAKERS & 46 STROBES AS PER PLANS."},{"number":"91426","date":"2007-07-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-17","scope":"INSTALL PLENUM CAT 6, 4-PAIR, #24 AWG. TO 21 LOCATIONS WITH ONE CABLE, AND TO 22 LOCATIONS WITH TWO CABLES, WITH THE LONGEST RUN AT 125 FT."},{"number":"93738","date":"2007-08-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-10-25","scope":"FURNISH AND INSTALL FIXTURES"},{"number":"95430","date":"2007-08-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"FOR INTERIOR ALTERATIONS TO THE 54TH FLOOR LOBBY AREA OF AN EXISTING HIGH-RISE BUILDING, AS SHOWN ON THE APPROVED PLANS."},{"number":"96410","date":"2007-08-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"RELOCATE 10 DIFFUSERS/REGISTERS (54TH FLOOR CORRIDORS)"},{"number":"96775","date":"2007-08-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-10-29","scope":"RELOCATE (12) AUTO SPRINKLERS ON THE 57TH FLOOR (07-6637)"},{"number":"66441","date":"2007-08-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-28","scope":"RELOCATE LIGHTING PER DRAWINGS, ADD RECEPTACLES AND SWITCHES PER 2005 NEC AND MODIFY FIRE ALARM. (CC DISTRICT)"},{"number":"99541","date":"2007-08-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-23","scope":"REPLACE EXISTING LIGHTING WITH NEW 10 - 2 X 2 LIGHTS, 16 - CHANNEL LIGHTS, RELOCATE FIRE ALARM DEVICES (4 SMOKES, 4 SPEAKER STROBES), AS PER 2005 NEC (CC DIST)."},{"number":"88792","date":"2007-08-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-23","scope":"REMODEL EXISTING OFFICE SPACE. RELOCATE 105 FXTS, NEW DOWNLIGHTS 120, NEW RECEPTS 150, NEW MOTION SWS 45. (CC DIST ) FIRE ALARM SYSTEM"},{"number":"87423","date":"2007-08-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-23","scope":"ELECTRICAL SVS EXISTING. NO CHANGE IN LOADS. NO TELA/DATA WIRING. RELOCAT EXISTING FIRE ALARM DEVICES. (CC DIST)"},{"number":"96573","date":"2007-08-31","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2009-01-08","scope":"PRELIMINARY PLAN REVIEW"},{"number":"101789","date":"2007-09-10","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-12-26","scope":null},{"number":"90834","date":"2007-09-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-17","scope":"PROVIDE AND INSTALL A TOTAL OF 380 CAT6 CABLES ON 42ND FLOOR, PROVIDE AND INSTALL A TOTAL OF 320 CAT6 CABLES ON 43RD FLOOR (CC DISTRICT)"},{"number":"101472","date":"2007-09-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"INTERIOR DEMO - FIT OUT OF SHOWROOM & OFFICES AS PER PLANS"},{"number":"104025","date":"2007-09-19","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"101291","date":"2007-09-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"LIMITED DEMOLITION AND INTERIOR FIT OUT OF EXISTING OFFICE SPACE ON THE 57TH FLOOR. NEW WOOD FLOORING, NEW PAINTING OF PARTITIONS. INTERIOR ALTERATIONS AS PER PLANS"},{"number":"104267","date":"2007-09-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-01-02","scope":"FIXTURE INSTALLATION"},{"number":"105022","date":"2007-09-24","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"104474","date":"2007-10-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-01-15","scope":"INTERIOR ALTERATIONS AS PER PLAN."},{"number":"107463","date":"2007-10-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-12-26","scope":"RELOCATION OF 15 DIFFUSERS/REGISTERS (3RD FLOOR - STEEL CASE)"},{"number":"105900","date":"2007-10-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-01-15","scope":"RENOVATIONS AS PER PLAN"},{"number":"108152","date":"2007-10-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2007-11-23","scope":"RELOCATE 16 SPRINKLER HEADS ON THE 1ST FLOOR OF LIBERTY PLACE"},{"number":"108033","date":"2007-10-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-28","scope":"RENOVATIONS TO EXISTING OFFICE SPACE TO INCLUDE: REPLACE 22 EXISTIG LIGHTS, 7 NEW LIGHTS, 3 SWITCHES, 5 RECEPTACLES, 1-110 VOLT JUBNCTION BOX, RELOCATE 1 EXISTING LIGHT, 12 TELE/DATA OUTLETS, EXISTING SERVICE PANEL (CC DIST)"},{"number":"104202","date":"2007-10-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-24","scope":"NEW LIGHTING AND POWER 30 RECEPTS, 40 LT FXTS, 23 SWS. ALL FIRE ALARM EXISTING TO RELOCATE: RELOCATING 6 DEVICES (CC DIST)"},{"number":"112278","date":"2007-10-30","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-01-15","scope":null},{"number":"112329","date":"2007-10-30","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-01-15","scope":null},{"number":"113144","date":"2007-11-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-03-08","scope":"FIXTURE INSTALLATION"},{"number":"113147","date":"2007-11-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-07-30","scope":"FIXTURE INSTALLATION"},{"number":"113374","date":"2007-11-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-15","scope":"RELOCATE 18 DIFFUSERS/REGISTERS - 56TH FLOOR - BRAVERMAN"},{"number":"113375","date":"2007-11-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-15","scope":"RELOCATE 16 DIFFUSERS/REGISTERS - 55TH FLOOR - THOMAS DUFFY"},{"number":"113516","date":"2007-11-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-11-07","scope":"INTERIOR ALTERATIONS AS PER PLANS"},{"number":"111682","date":"2007-11-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-12","scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT. INSTALL 143 LIGHT FIXTURES, 31 WALL SWITCHES, 34 RECEPTS, 12 WALL FURNITURE FEEDS AND 1 HVAC FEED AND REUSE EXISTING PANELS 1 NEW 208/128V PANEL, 3 HOT WATER HEATER FEEDS AND 1 PUMP FEED (CC DIST)"},{"number":"111681","date":"2007-11-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-12","scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT. INSTALL 142 LIGHT FIXTURES, 10 WALL SWITCHES, 36 RECEPTS, 4 WALL FURNITURE FEEDS AND 1 HVAC FEED AND REUSE EXISTING PANELS (CC DIST)"},{"number":"101948","date":"2007-11-29","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2007-11-29","scope":"FOR THE ERECTION OF (1) ONE WIRELESS TELECOMMUNICATION ANTENNA ON AN EXISTING ROOFTOP (SPIRE)WITH EXISTING WIRELESS ANTENNA. FOR USE AS A WIRELESS TELECOMMUNICATION/ TELEVISION SERVICE ON AN EXISTING SPIRE WITH EXISTING WIRELESS ANTENNA AND EXISTING OFFICE BUILDING WITH USES AS PREVIOUSLY APPROVED."},{"number":"113401","date":"2007-12-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-02","scope":"FURNISH AND INSTALL 42 CAT 5E PLENUM CABLES AND 34 CAT 6 PLENUM CABLES (CC DISTRICT)"},{"number":"87426","date":"2007-12-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL FIRE ALARM DEVICES CONNECTED TO AN EXISTING SYSTEM. (7) SPEAKERS ONLY, (4) SPEAKER/STROBE, (2) STROBE ONLY, (1) SMOKE DETECTOR AND (1) DOOR INTERFACE. (CC DIST)"},{"number":"120524","date":"2007-12-10","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-10-21","scope":"INSTALL 55 CAT-6 AND 2 PATCH PANELS. (CC DIST) INSTALL 55 CAT-6 AND 2 PATCH PANELS. (CC DIST)"},{"number":"119829","date":"2007-12-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"TENANT FIT-OUT AS PER PLAN."},{"number":"123587","date":"2007-12-26","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-03-31","scope":"FURNISH AND INSTALL (27) DATA LOCATIONS, FURNISH AND INSTALL (1) 25 PAIR VOICE FEED, AVERAGE LENGTH 150' (CC DIST) FURNISH AND INSTALL (27) DATA LOCATIONS, FURNISH AND INSTALL (1) 25 PAIR VOICE FEED, AVERAGE LENGTH 150' (CC DIST)"},{"number":"124627","date":"2008-01-03","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-02-28","scope":null},{"number":"122943","date":"2008-01-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-05","scope":"HVAC INCLUDING DUCTWORK PER PLANS"},{"number":"125475","date":"2008-01-08","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-05-13","scope":null},{"number":"124515","date":"2008-01-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 13 SPEAKER/STROBES, 1 STROBE & (1) BOOSTER PANEL, CONNECT TO EXISTING BUILDING SYSTEM. (CC DIST)"},{"number":"124518","date":"2008-01-09","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2023-12-01","scope":"INSTALL 15 SPEAKER/STROBES, 2 STROBE & (1) BOOSTER PANEL, CONNECT TO EXISTING BUILDING SYSTEM. (CC DIST INSTALL 15 SPEAKER/STROBES, 2 STROBE & (1) BOOSTER PANEL, CONNECT TO EXISTING BUILDING SYSTEM. (CC DIST"},{"number":"125756","date":"2008-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-06-26","scope":"FIXTURE INSTALLATION"},{"number":"125762","date":"2008-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-08-19","scope":"FIXTURE INSTALLATION"},{"number":"124133","date":"2008-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-06-10","scope":"DEMO EXISTING PANTRIES- CUT AND CAP WASTE AND WATER LINES"},{"number":"126630","date":"2008-01-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION OF LFFICE SPACE, CHANGE OUT OF 8 RECEPTS OUTLETS, 16 LIGHT FIXTURES, 8 SWITCHES, 6 FLOOR OUTLETS AS PER 2005 NEC (CC DISTRICT)"},{"number":"127560","date":"2008-01-21","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-10-22","scope":null},{"number":"126449","date":"2008-01-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-10-07","scope":"STRUCTURAL STEEL/SLAB REINFORCING FOR THE 55TH FLOOR AS PER PLANS"},{"number":"127852","date":"2008-01-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"RELOCATE 6 DIFFUSERS."},{"number":"127938","date":"2008-01-23","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"125713","date":"2008-01-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2021-02-24","scope":"INSTALL 253 VOICE/DATA COMMUNICATION OUTLETS."},{"number":"118734","date":"2008-02-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"ERECTION OF FOUR (4) WIRELESS TELECOMMUNICATION ANTENNAS ON EXISTING ROOFTOP WITH EXISTING WIRELESS ANTENNA & EQUIPMENT INSIDE ROOM. PROFESSIONAL ENGINEER OF RECORD SHALL SUBMIT A LETER OF FINAL COMPLINACE BEFORE FINAL PERMIT IS ISSUED. ALL WORK SHALL CONFOR TO THE APPROVED PLANS."},{"number":"130278","date":"2008-03-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-12","scope":"INSTALL 70 CAT 6 PLENUM CABLES, LONGEST RUN 200'."},{"number":"138309","date":"2008-03-14","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":null},{"number":"137473","date":"2008-03-20","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-09-09","scope":"INTERIOR FITOUT OF FLOORS 37-41 AS PER PLANS"},{"number":"140219","date":"2008-03-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-29","scope":"INSTALL CAT5E LOW VOLTAGE CABLE FOR BOICE AND DATA, TOTAL OF 37 CABLES, LONGEST RUN 185' AS PER 2005 NEC (CC DISTRICT)"},{"number":"140555","date":"2008-03-25","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-04-30","scope":"INTERIOR NON-BEARING DEMOLITION (30TH FLOOR)"},{"number":"139544","date":"2008-03-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-10-08","scope":"INSTALL 2 TRANSFORMERS, INSTALL 1 SQUARED DISCONNECT BREAKER, INSTALL ONE TRANSMITTER SWITCH, INSTALL ONE METER SOCKET, INSTALL NEW FEEDER. NO FIRE ALARM WORK. SECO # 9330 (CC DIST)"},{"number":"137471","date":"2008-03-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-11-12","scope":"MINOR DEMOLITION, INTERIOR RECONSTRUCTION OF EXISTING OFFICE SPACE AS PER PLANS PERMIT INCLUDES THE REMOVAL OF NON BEARING INTERIOR PARTITIONS AND THE ERECTION OF NON-COMBUSTIBLE PARTITION WALLS AND CEILINGS TO CREATE OFFICE SPACE, A CONFERENCE ROOM, AND KITCHENETTE/BREAK AREA AS SHOWN ON THE APPROVED PLAN. ADDITIONAL PERMITS REQUIRED FOR; ELECTRICAL, TELE-DATA, MECHANICAL ( EQUIPMENT AND DUCTWORK ) AND FIRE SUPPRESSION"},{"number":"141862","date":"2008-03-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-07-15","scope":"INSTALL ALL DRAIN, WASTE & VENT PIPING FOR (1) NEW PANTRY SINK, WITH DOMESTIC WATER PIPING. INSTALL (1) NEW 6 GALLON ELEC WATER HEATER."},{"number":"146353","date":"2008-04-18","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-06-30","scope":"FIXTURE INSTALLATIONS"},{"number":"146428","date":"2008-04-18","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"INTERIOR NON-BEARING DEMOLITION (54TH FLOOR)"},{"number":"146693","date":"2008-04-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"RELOCAT DIFFUSERS"},{"number":"137032","date":"2008-04-28","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2008-10-07","scope":"AMEND PERMIT # 113516 FOR THE RE-LOCATION OF ADA TOILET ROOM AS PER PLAN."},{"number":"146942","date":"2008-04-30","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-09","scope":"INSTALLATION ENW, REPLACE EXISTING DUCT WORK, ACCESSORY MECHANICALS, AS PER PLANS."},{"number":"149185","date":"2008-05-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-12-03","scope":"FIXTURE INSTALLATION"},{"number":"149773","date":"2008-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-13","scope":"RELOCATE 6 DIFFUSERS/REGISTERS (44TH FLOOR, TOILET ROOMS)"},{"number":"150699","date":"2008-05-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-08-18","scope":"RELOCATE 1 REGISTER/DIFFUSER - TOILET ROOM 22ND FL"},{"number":"150862","date":"2008-05-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-08-04","scope":"RELOCATE 1 REGISTER/DIFFUSER - 3RD FLOOR TOILET ROOM"},{"number":"123012","date":"2008-05-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-08","scope":"INSTALL 300 NEW RECEPTACLES, 22 FURNITURE FEEDS, 35 SWITCHES, 550 NEW LIGHTS, 31 EXISTING SIGNS (CC DIST)"},{"number":"155293","date":"2008-05-30","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-09-09","scope":null},{"number":"155335","date":"2008-05-30","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"154701","date":"2008-06-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-08-11","scope":"INTERIOR ALTERATIONS"},{"number":"155627","date":"2008-06-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 2 LIGHTS, 1 SWITCH AND 1 GFI RECEPTACLE AS PER 2005 NEC (CC DIST)"},{"number":"151541","date":"2008-06-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-25","scope":"INSTALL 2068 CAT6 PLENUM CABLES FOR VOICE & DATA APPLICATION INSTALL COPPER & FIBER RISER CABLES AS PER 2005 NEC (CC DISTRICT)"},{"number":"145472","date":"2008-06-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-02-20","scope":"NEW AUTOMATIC FIRE SUPPRESSION SYSTEM"},{"number":"148908","date":"2008-06-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-10","scope":"INSTALL CLEAN AGENT FIRE ALARM PANEL, INITIATING AND NOTIFICATION DEVICES AND CIRCUITS, AS PER NFPA-72 (CC DIST)"},{"number":"148938","date":"2008-06-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-08-11","scope":"ADDITION OF ADA TIOLET ROOM ON 22ND FLOOR"},{"number":"156658","date":"2008-06-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-09","scope":"INSTALL 22 STROBES, 30 MONITOR MODULES, 18 SMOKES, 18 PULL STATIONS, 109 HORN/STROBES & 1 FACP."},{"number":"134595","date":"2008-07-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-20","scope":"TYPICAL FLOOR RENOVATIONS, 1,518 LIGHT FIXTURES, 745 RECEPTS, 65 SWITCHES, 142 OCCUPANCY SENSORS, AND 32 DIMMERS, FIRE ALARM WILL BE SUBMITTED UNDER A SEPARATE COVER NOT INCLUDED AS PER 2005 NEC (CC DISTRICT)"},{"number":"153962","date":"2008-07-02","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-04-13","scope":"INSTALL FIRE SUPPRESSION SYSTEM"},{"number":"165317","date":"2008-07-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-03","scope":"INSTALLATION OF CAT 5E PLENUM RATED CABLING TO 34 PHONE/DATA OUTLETS, 50PAIR RISER CABLING WITHIN TENANT SPACE AS PER ARTICLES 300.21 AND 800 AS PER 2005 NEC (CC DISTRICT)"},{"number":"160447","date":"2008-07-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-08-07","scope":"INSTALLATION OF A LOW VOLTAGE (12VNC)BURGLAR ALARM SYSTEM AND CARD ACCESS (CC DISTRICT)"},{"number":"156114","date":"2008-08-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-09-09","scope":"INSTALL SPRINKLERS"},{"number":"169706","date":"2008-08-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 1 NEW LIGHT, 1 SWITCH AND 1 GFI RECEPT AS PER 2005 NEC (CC DISTRICT)"},{"number":"169707","date":"2008-08-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 1 NEW LIGHT, 1 SWITCH AND 1 GFI RECEPT AS PER 2005 NEC (CC DISTRICT)"},{"number":"171122","date":"2008-08-14","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-11-05","scope":null},{"number":"169352","date":"2008-08-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-12-03","scope":"TENANT FIT OUT TO INCLUDE DRYWALL, MILLWORK ND FINISHES ON PARTIAL 22ND & 23RD FLOORS PER SUBMITTED SEALED PLANS. C.O.N.R."},{"number":"172493","date":"2008-08-21","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-11-19","scope":"FIXTURE INSTALLATION"},{"number":"172243","date":"2008-08-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"HVAC INCLUDING DUCTWORK AS PER PLANS"},{"number":"175144","date":"2008-09-05","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-03-09","scope":"INSTALL 78 DUEL CAT 5E OUTLETS WITH PLENUM CABLE. 156 TOTAL CABLES 200FT LONGEST CABLE (CC DIST) INSTALL 78 DUEL CAT 5E OUTLETS WITH PLENUM CABLE. 156 TOTAL CABLES 200FT LONGEST CABLE (CC DIST)"},{"number":"172300","date":"2008-09-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-09","scope":"FURNISH/INSTALL 32DUPLEX RECEPT,60 DOUBLE DUPLES RECEPTS,6 DED DUP RECEPS,(64)V/D RW'S,(8)GFI RECEPTS,(16)PWR FOR FAN UNITS,(1)PWR FOR HWH, (207)DOWNLTS,(14)UNDER SCAB LTS,(30)2X4 LTS,(66) 2X4 LTS,(2) PEN LTS,(7) EX SGNS,(42) SPW,(22) SPD,(2) 3-WAY SW'S,(10) REMOVE/RELO 2X4 LTS,(10)REM/REL WIREMOLD W/6 DUP RECPTS, NO FA PER 2005 NEC(CC DIST)"},{"number":"177495","date":"2008-09-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-10-09","scope":"INTERIOR ALTERATIONS TO EXISTING OFFICE SPACE."},{"number":"179065","date":"2008-09-25","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2008-09-25","scope":"FOR PREPARING AND SERVING OF HOT AT COLD FOOD AND RETAIL SALE OF SAME WITHIN AN EXISTING EMPLOYEE FOOD AREA AND ACCESSORY TO AN EXISTING OFFICE ON THE 24TH FLOOR IN AN EXISTING OFFICE BUILDING WITH USES AS PREVIOUSLY APPROVED."},{"number":"179563","date":"2008-09-29","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-10-28","scope":null},{"number":"174549","date":"2008-09-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-03-29","scope":"FURNISH AND INSTALL 5 STROBES, 13 SPEAKERS, 10 HORN STROBES AND 1 BOOSTER PANEL AS PER NFPA72 (CC DISTRICT)"},{"number":"178874","date":"2008-10-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-30","scope":"RENOVATION OF EXISTING OFFICE SPACE.RELOCATE LT FXTS FOR NEW LAYOUT. RELOCATE EXISTING FURN FEED CRTS FOR NEW CONFIGURATION.ADD DUP RECEPTS IN NEW OFFICE & USE CRTS FREED UP FROM DEMO.RE-INSTALL EXISTING FIRE DEVICES IN NEW CEILING TILES. (CC DIST)"},{"number":"180353","date":"2008-11-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-10-09","scope":"HVAC INCLUDING DUCTWORK"},{"number":"166951","date":"2008-11-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL PANEL & DEVICES FOR CLEAN AGENT SUPPRESSION SYSTEM AS SHOWN ON PLANS."},{"number":"179736","date":"2008-11-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-12","scope":"RE-USE EXISTING CABLE/RELOCATE \"ALL\" CABLES FOR NEW FURNITURE CONFIGURATION, INSTALL (10) CATEGORY 6 PLENUM CABLES, LONGEST RUN 150 FEET, AS PER 2005 NEC (CC DIST)"},{"number":"61486","date":"2008-12-18","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2008-12-18","scope":"FOR AN EAT IN ONLY RESTAURANT WITH SEATING FOR A MINIMUM OF (THIRTY) 30 PERSONS ON THE 37TH FLOOR FOR AN EXISTING BUILDING WITH 130 APARTMENTS AND PREVIOUSLY APPROVED USES."},{"number":"194363","date":"2009-01-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-04-27","scope":"ALTERATIONS TO INCLUDE RECONFIGURING AREA, DEMO AND REPLACE PORTIONS OF EXISTING CEILING GRID AND TILE, UPGRADE EXISTING FINISHES. SEPARATE MECHANCIAL (SEE AP #197420), ELECTRICAL AND SPRINKLER PERMITS REQUIRED."},{"number":"197420","date":"2009-01-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-04-27","scope":"DEMO EXISTING AND INSTALL NEW DIFFUSERS, DUCT WORK, ACCESSORY MECHANICALS, AS PER PLANS FOR NEW LAYOUT APPROVED UNDER AP #194363. CONNECT TO EXISTING HVAC SYSTEM."},{"number":"198401","date":"2009-03-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-09","scope":"SELECTIVE DEMOLITION OF LIGHTS AND POWER. ADD 23 DUPLEX RECEPTS, 131 LIGHT FIXTURES, 6 POKE THRUS, 6 FURNITURE FEEDS, 19 SINGLE POLE LIGHT FIXTURES, NO FIRE ALARM AS PER 2005 NEC (CC DISTRICT)"},{"number":"203560","date":"2009-03-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-04-27","scope":"RELOCATE 52 SPRINKLER HEADS (44TH FLOOR ONE LIBERTY PLACE)"},{"number":"210799","date":"2009-04-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-06-17","scope":"RELOCATE(4) DIFFUSERS"},{"number":"211057","date":"2009-04-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-11-11","scope":"FIXTURE INSTALLATION"},{"number":"202976","date":"2009-04-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 56 VOICE/DATA COMMUNICATION OUTLETS CAT5E 4 PAIR PLENUM RATED LONGENT RUN 125' AS PER 2005 (CC DISTRICT)"},{"number":"211732","date":"2009-04-21","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"207126","date":"2009-04-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-09","scope":"ADD 2 SPEAKER/STROBES & RELOCATE 3 SMOKE DETECTORS."},{"number":"220089","date":"2009-06-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-03","scope":"(1) SIGN CONNECTION, (5) DUPLEX RECEPTACLES, (6) GFI RECEPTACLES, AS PER 2005 NEC (CC DIST)"},{"number":"227184","date":"2009-07-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-08-31","scope":"TENANT FIT OUT FOR CANON SOLUTIONS AS PER PLAN."},{"number":"230064","date":"2009-08-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-08-21","scope":"INSTALL SINK AND WATER HEATER"},{"number":"229989","date":"2009-08-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-14","scope":"40 LOC'S OF 3-4PR CAT6 24AVG COPPER WIRE, 12 LOCATIONS OF 2-4PR CAT6 24AVG COPPER WIRE, CAT6 PLENUM CABLE, 2 CABLE LOCATIONS AVG LENGTH-150', 3 CASE LOCATIONS AVG LENGTH-125',ALL WIRE TO BE TERM, LABELED/TESTED ON CAT6 PATCH PANELS/JACKS,PER 2005 NEC(CC DIST)"},{"number":"231855","date":"2009-08-13","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-08-31","scope":null},{"number":"231326","date":"2009-08-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-08-31","scope":"TENANT FIT OUT FOR CANON SOLUTIONS AS PER PLAN."},{"number":"229487","date":"2009-08-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-01","scope":"FURNISH AND INSTALL 140 RECEPTS, 10 OCCUPANCY SENSORS, 71 - 2X4 LIGHTS, 7 - 2X2 LIGHTS, 50 DOWN LIGHTS, 1 - 225AMP PANEL, POWER TO MECHANICAL UNITS AS PER 2005 NEC (CC DISTRICT)"},{"number":"235240","date":"2009-09-24","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-10-30","scope":"INTERIOR ALTERATIONS AS PER PLAN."},{"number":"232312","date":"2009-10-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-03-15","scope":"INSTALL 1 FIRE ALARM BOOSTER, 15 SMOKE DETECTORS, 2 PULL STATIONS, 8 STROBES, 1 SPEAKER, 1 HEAT DETECTOR AS PER NFPA72 (CC DISTRICT)"},{"number":"240663","date":"2009-10-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-01-29","scope":"REMOVE AND RELOCATE 6 - 2X4 FIXTURES, ADD 7 DUPLEX RECEPTS, 14 QUAD RECEPTS, 2 GFI'S, 4 FURNITURE FEEDS AS PER 2005 NEC (CC DISTRICT)"},{"number":"240794","date":"2009-10-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-07-14","scope":"FURNISH AND INSTALL (30)CAT 5E VOICE DATA DROPS"},{"number":"245659","date":"2009-10-30","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-11-02","scope":null},{"number":"244728","date":"2009-11-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-02-24","scope":"INTERIOR ALTERATIONS AS PER PLANS.PERMIT TO INCLUDE INTERIOR DEMOLITION, AND THE INSTALLATION OF NON COMBUSTIBLE PARTITIONS IN AN EXISTING B USE SPACE. SEPARATE PERMITS REQUIRED FOR MECHANICAL,ELECTRICAL, AND FIRE SUPPRESSION WORK REQUIRED."},{"number":"247127","date":"2009-11-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-30","scope":"REMOVE EXISTING 2X2 AND REPLACE WITH NEW 2X2 FIXTURES (48), CHANGE SWITCHES TO MOTION SWITCHES, FIRE ALARM EXISTING AND RELOCATE DEVICES (2), RELOCATE RECEPTACLES AND ADD (12) NEW, NO CHANGE IN LOAD, AS PER 2005 NEC (CC DIST)"},{"number":"247587","date":"2009-11-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-02-24","scope":"RELOCATE (15) DIFFUSERS."},{"number":"247626","date":"2009-11-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-07-20","scope":null},{"number":"242590","date":"2009-11-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-01","scope":"HVAC, INCLUDING DUCTWORK, AS PER PLANS"},{"number":"246971","date":"2009-11-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-07-20","scope":"INTERIOR ALTERATIONS, AS PER PLANS"},{"number":"249736","date":"2009-11-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-07-20","scope":"RELOCATE (2) DIFFUSERS."},{"number":"244618","date":"2009-11-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-01","scope":"ADD 3 SPEAKER/STROBES TO EXISTING FIRE ALARM SYSTEM."},{"number":"248275","date":"2009-12-04","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-02-24","scope":"INTERIOR ALTERATIONS AS PER PLANS. PERMIT TO INCLUDE MINOR INTERIOR DEMOLITION AND THE INSTALLATION OF PARTITIONS TO RECONFIGURE A SINGLE EXIT, B USE GROUP TENANT SPACE. SEPARATE PERMITS REQUIRED FOR ELECTRICAL, MECHANICAL, AND SPRINKLER WORK."},{"number":"252295","date":"2009-12-08","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2010-02-24","scope":null},{"number":"252963","date":"2009-12-11","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2010-02-24","scope":null},{"number":"253192","date":"2009-12-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-01-05","scope":"RELOCATE (12) DIFFUSERS."},{"number":"253302","date":"2009-12-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-03","scope":"INSTALL 25 CATEGORY 6 PLENUM RATED CABLES, LONGEST RUN 100', AS PER 2005 NEC ARTICLE 800."},{"number":"253426","date":"2009-12-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-07-29","scope":"REMOVE AND RELOCATE (6) 2 X 4 LIGHTS, ADD (1) SWITCH, ADD (1) POKE THRU, ADD (2) DUPLEX RECEPTACLES AS PER 2005 NEC (CC DIST)"},{"number":"250887","date":"2009-12-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-05-18","scope":"INTERIOR ALTERATIONS TO INSTALL A SECURITY DESK IN THE LOBBY AREA AS PER PLANS."},{"number":"255462","date":"2010-01-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-29","scope":"RELOCATE LOW VOLTAGE FOR SECURITY DESK, ADD 480V 25A FEED TO 15KVA TRANSFORMER, 10 KVA UPS, 208V PANEL & 9 120V 20A CIRCUITS."},{"number":"247586","date":"2010-02-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-05-18","scope":"INSTALL DUCTWORK TO SERVE SECURITY STATION ON LOBBY LEVEL"},{"number":"262674","date":"2010-02-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-10","scope":"FURNISH AND INSTALL (3) 2 X 2 FIXTURES, (1) SWITCH AND (1) GFI RECEPTACLE AS PER 2005 NEC (CC DIST)"},{"number":"276623","date":"2010-05-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-07-14","scope":"5 POWER WIRE HVAC EQUIPMENT 480V 30 15 AMP EACH AS PER 2008 NEC (CC DISTRICT)"},{"number":"269471","date":"2010-06-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-09-16","scope":"INSTALL WATER SOURCE HEAT PUMPS ON 58TH TO 61ST FLOORS AS PER PLANS."},{"number":"295090","date":"2010-08-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-09-15","scope":"INTERIOR ALTERATIONS AS PER PLANS."},{"number":"295933","date":"2010-08-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-03-09","scope":"RELOCATE 4 SPRINKLER HEADS ON 47TH FLOOR, EXISTING OFFICE SPACE."},{"number":"294648","date":"2010-08-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-03-09","scope":"INTERIOR FIT OUT, PER PLAN"},{"number":"297347","date":"2010-08-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-21","scope":"INSTALL 18 NEW QUAD RECEPTACLES UTILIZING EXISTING CIRCUITS (PER2008 NEC CODE)"},{"number":"301469","date":"2010-09-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"TENANT FIT-OUT TO CREATE OFFICE SPACE"},{"number":"296829","date":"2010-09-29","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-03-28","scope":"INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE. NO STRUCTURAL WORK IN THIS APPLICATION."},{"number":"303066","date":"2010-10-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"HVAC SYSTEM ALTERATIONS FOR OFFICE FITOUT, AS PER PLANS."},{"number":"304719","date":"2010-10-05","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"RELOCATE 130 EXISTING SPRINKLER HEADS (54TH FLOOR)"},{"number":"303297","date":"2010-10-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"FURNISH AND INSTALL WATER CLOSET, LAVATORY, (3)PANTRY SINKS, MOP SINK- CONNECT TO EXISTING SERVICES"},{"number":"303841","date":"2010-11-05","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2023-12-01","scope":"re use existing fixtures,66 now layin fixtures,86 now down lights,40 track lights,14 new exit lights, 25 switches. 36 motion sensors switches, 88 receptacles, 10 furniture as per 2008 nec"},{"number":"310705","date":"2010-11-15","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-03-25","scope":"INTERIOR DEMO ONLY OF NON LOAD BEARING ASSEMBLIES ONLY."},{"number":"310435","date":"2010-12-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-06-27","scope":"INSTALLATION OF HVAC INCLUDING DECTWORK AS PER PLANS, IN LOWER LEVEL."},{"number":"308892","date":"2010-12-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"PROVIDE AND INSTALL 62 CABLE DROPS WITH CAT 6 PLENUM RATED CABLE AS PER 2008 NEC"},{"number":"307301","date":"2010-12-08","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2023-12-01","scope":"add 1 new fire booster panel,add 20 new speaker strobes,add 1 new strobe as per 2008 nec"},{"number":"313403","date":"2010-12-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-03-25","scope":"INTERIOR ALTERATIONS TO RECONFIGURE EXISTING OFFICE SPACE."},{"number":"318854","date":"2010-12-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RELOCATE 10 LIGHTS,3 SWITCHES,3 PANEL OUTLET,UTILIZE EXISTING ELECTRIC SERVICE AS IS NO TELE COM NO FIRE ALARM AS PER 2008 NEC"},{"number":"317580","date":"2011-01-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-02-27","scope":"INTERIOR RENOVATION FOR LAW FIRM. DEMO OF EXISTING WALLS AND MEP SYSTEM, MODIFICATION TO FIRE PROTECTION."},{"number":"322651","date":"2011-01-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-02-27","scope":"RELOCATE 745 HEADS ON FLOORS 15-20"},{"number":"321295","date":"2011-02-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-02-27","scope":"FURNISH AND INSTALL KITCHEN SINKS, WATER CLOSETS, SHOWERS AND LAVATORIES"},{"number":"321276","date":"2011-02-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-02-27","scope":"FOR THE INSTALLATION OF A NEW COMPLEX HVAC SYSTEM INCLUDING DUCTWORK & MECHANICAL UNITS WITH PIPING. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. THIS WORK ACTIVITY SHALL BE PERFORMED BY A CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"326992","date":"2011-03-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-09-14","scope":"INTERIOR ALTERATIONS MODIFY EXISTING MILLWORK IN TWO CONFERENCES ROOMS."},{"number":"322387","date":"2011-03-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-20","scope":"LIGHTING, POWER AND FIRE ALARM FIT OUT WORK FOR 6 FLOORS OF RENOVATED OFFICE SPACE AS SHOWN ON ATTACHED ELECTRICAL AND FIRE ALAR DRAWINGS"},{"number":"324111","date":"2011-03-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-29","scope":"ADD 10 FIRE SPEAKERS IN EAST FIRE TOWER PER SIEMENS DWGS 1-18-11, ADD 10 FIRE SPEAKERS IN WEST FIRE TOWER AS PER SIEMENS DWGS 1-18-11 AS PER 2008 NEC."},{"number":"324858","date":"2011-03-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FIRE ALARM SYSTEM AS PER NFPA-72 (CC DIST)"},{"number":"327215","date":"2011-03-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLING NEW CAT 6E PLENUM CABLES TO SUPPORT VOICE OVER IP PHONE SYSTEM AS PER 2008 NEC.INSTALLATION TO COMPLY WITH ARTICLES 300.21, 800.113, 800.133, 800.154 & 800.179."},{"number":"326433","date":"2011-03-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-29","scope":"INSTALL 3 NEW SMOKE DETECTORS,RELAY AND HEAT FOR SHUNT TRIP BREAKER FURNISH AND INSTALL SHUNT TRIP BREAHER, NEW SAFTEY SWITCH AND WIRE TO NEW ELEVATOR CONTROLLER AS PER 2008 NEC"},{"number":"327478","date":"2011-04-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-09-14","scope":"ADDING (4) SPRINKLER HEADS IN DATA ROOM AS PER DRAWINGS FOR OFFICE."},{"number":"339861","date":"2011-05-09","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-06-06","scope":"REMOVING RADIO EQUIPMENT FROM MECHANICAL ROOM."},{"number":"343791","date":"2011-05-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLATION OF A LOW VOLTAGE BURGLAR ALARM SYSTEM AND CAMERAS (BANK OF AMERICA)"},{"number":"344235","date":"2011-06-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-08-25","scope":"INTERIOR ALTERATIONS AS PER PLANS."},{"number":"349842","date":"2011-06-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-08-27","scope":"RELOCATE 50 EXISTING SPRINKLER HEADS - 57TH FLOOR"},{"number":"355315","date":"2011-07-28","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-08-25","scope":"INTERIOR DEMOLITION OF NON LOAD BEARING PARITIONS FOR AN OFFICE SPACE IN A HIGH RISE BUILDING. FIRE RATED ASSEMBLIES, SPRINKLER AND FIRE ALARM SYSTEMS ARE TO BE MAINTAINED AT ALL TIMES. CALL THE INSPECTOR PRIOR TO STARTING WORK."},{"number":"357672","date":"2011-08-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"INTERIOR RENOVATIONS TO THE 53RD FLOOR OFFICE SPACE AS PER PLANS."},{"number":"360240","date":"2011-08-30","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-10-13","scope":"INSTALL NEW HVAC INCLUDING DUCTWORK 1ST FLOOR"},{"number":"361857","date":"2011-09-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"RELOCATE (65) SPRINKLERS OF OFFICE BLDG."},{"number":"361017","date":"2011-09-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"1 SINK"},{"number":"362409","date":"2011-09-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"RELOCATE (16) DIFFUSERS."},{"number":"362192","date":"2011-09-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-21","scope":"INSTALL LIGHT & NPOWER FOR OFFICE FIT-OUT. NO FIRE ALARM."},{"number":"350255","date":"2012-01-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-02-17","scope":"INTERIOR IMPROVEMENTS TO EXISTING OFFICE SPACE TO INCLUDE UPGRADES TO MILLWORK, FINISHES, BUILT IN FURNISHING AND RELOCATION OF FIXTURES."},{"number":"398339","date":"2012-04-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-06-01","scope":"RELOCATE 2 SPRINKLERS ON THE 30TH FLOOR"},{"number":"398834","date":"2012-04-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-06-01","scope":"RELOCATE (5) DIFFUSERS ON THE 30TH FLOOR. J.P. MORGAN"},{"number":"397118","date":"2012-04-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-05-18","scope":"INTERIOR ALTERATIONS/TENANT IMPROVEMENTS, NEWER PARTIITONS, CEILINGS, UPGRADES TO FINISHES FOR EXISTING OFFICE SPACE. BUILDING SPRINKLERED. NO CHANGE IN OCCUPANCY CLASSIFICATIONS. ADD'L PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS."},{"number":"400036","date":"2012-04-18","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-05-18","scope":"RELOCATION OF (13) SPRINKLERS ON THE 37TH & 38TH FLOORS IN THE AIG CHARTIS SPACE"},{"number":"400282","date":"2012-04-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-06-13","scope":"RENOVATE SPACE INCL INSTALLING LIGHT FIX, WALL SWITCHES, RECPETS AND RELOCATING LIGHT FIXTURES AND FURNITURE FEEDS AS PER 2008 NEC. REUSE EXISTING CIRCS FROM DEMO. NO CHANGES IN LOAD(COMMERCIAL)(CC DIST)"},{"number":"401413","date":"2012-05-01","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-05-18","scope":"HVAC, INCLUDING DUCTWORK, AS PER PLANS WITH (7) REGISTERS/DIFFUSERS FOR OFFICE BLDG."},{"number":"394524","date":"2012-05-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-06-12","scope":"INTERIOR ALTERATIONS TO OFFICE SPACE AS PER PLANS."},{"number":"406901","date":"2012-05-24","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-11-20","scope":"INSTALLATION OF A PANTRY SINK"},{"number":"402690","date":"2012-05-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-09-25","scope":"INSTALL 25 2X4'S, 2 EXIT SIGNS, 5 DOWN LIGHTS, 2 QUAD RECEPTS, 8 DUPLEX RECEPTS, 5 TELE/DATA STUBS, 1 FURNITURE FEED AS PER 2008 NEC (CC DIST) OFFICE SPACE"},{"number":"405655","date":"2012-06-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-10-24","scope":"INSTALL CARD ACCESS AND CAMERAS AS PER 2008 NEC(COMMERCIAL-HIGH RISE)(CC DIST)INSTALLATION TO COMPLY WITH ARTICLES 300.21 & 725.3 OF THE 2008 NEC."},{"number":"404590","date":"2012-06-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-01","scope":"INSTALL 5 STROBES, RELOCATE 2 SPEAKER & INSTALL 1 SPEAKER AS PER NFPA 72 (OFFICE BLDG)"},{"number":"414307","date":"2012-08-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-03-18","scope":"SELECTIVE DEMO. ALTERATIONS AS PER PLAN INCLUDES PATCH AND REPAIR CEILINGS AND NEW WALLS"},{"number":"422519","date":"2012-08-16","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2012-11-01","scope":"15000 SQUARE FEET, INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILINGS ONLY ON THE 33RD FLOOR. NO OTHER WORK ALLOWED UNDER THIS PERMIT. SEPARATE PERMITS REQUIRED FOR INTERIOR RENOVATION. NO STRUCTURAL CHANGES. MUST MAINTAIN ALL CODE REQUIRED FIRE RATING ON WALL AND FLOOR/CEILING ASSEMBLIES. THREE SETS OF PLANS DRAWN TO PROFESSIONAL QUALITY ARE TO BE SUBMITTED FOR REVIEW AND APPROVAL BY THE DEPARTMENT BEFORE WORK ON RENOVATION STARTS."},{"number":"422591","date":"2012-08-21","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2013-03-18","scope":"CHANGE CONTRACTOR INFORMATION ON PERMIT AP# 414307."},{"number":"421373","date":"2012-09-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLATION OF 116 DUAL DATA ONE COAX LOCATIONS 16 TRIPLEX DATA LOCATION 1-12 STRAND FIBER OPTIC RUN FROM MDF TO IDF PER 2008 NEC (ALL MATERIALS WILL BE PROVIDED BY CUSTOMER PRICES INCLUDES LABOR 35K, MATERIALS 44,785.27)"},{"number":"426744","date":"2012-09-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-03-19","scope":"RELOCATE (13) EXISTING SPRINKLER HEADS - 41ST FLOOR"},{"number":"428105","date":"2012-09-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-10-02","scope":"RELOCATE 9 DIFFUSERS IN OFFICE BUILDING"},{"number":"422554","date":"2012-09-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-04-17","scope":"INTERIOR ALTERATIONS TO THE 33RD FLOOR OF A HIGH RISE BUILDING AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING."},{"number":"426602","date":"2012-09-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-12-07","scope":"INSTALL 20 DUPLEX RECEPTACLE 22 QUAD RECEPTACLES 30 TELE/DATA STUBS, 1-120/208 V PANEL, 9 RELOCATING EXISTING 2X2 LIGHTS 1 POKE TRUTH PER 2008 NE (OFFICE SPACE)"},{"number":"432153","date":"2012-10-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-04-15","scope":"INSTALLATION OF A KITCHEN SINK"},{"number":"425547","date":"2012-10-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-12-12","scope":"ADD STROBE LIGHT TO NEW CONFERENCE ROOM AS PER 2008 NEC AND NFPA72 (COMMERCIAL)"},{"number":"431509","date":"2012-11-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-04","scope":"REPLACE DISC SWITCH WITH SHOT TRIP BREAKER CHANGE 3-LIGHTS, CHANGE 3-OUTLETS TO GFI FURNISH & INSTALL 7-CONTROL RELAYS 4- SINGLE INPUT MODULES AS PER NEC 2008 & NFPA 72(COMM OFFICE BLDG)"},{"number":"431439","date":"2012-11-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-05-22","scope":"MECHANICAL ALTERATIONS, DEMOLITION AND INSTALLATION OF NEW DUCTWORK, DIFFUSERS, MECHANICAL ACCESSORIES, EQUIPMENT IN CONJUNCTION WITH ALTERATIONS/RECONFIGURATION OF FLOOR SPACE AP422554"},{"number":"437154","date":"2012-11-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-03-25","scope":"INSTALL LOW VOLTAGE CABLING FOR VOICE DATA AS PER NEC 2008. INSTALLATION TO COMPLY WITH ARTICLES 300.21 & 800 OF THE 2008 NEC."},{"number":"434955","date":"2012-12-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-04-20","scope":"INST 50 DUPLEX RECEP 6 QUAD RECEP 5 POKE THRUS 3 WALL FURN FEEDS 1 POWER TO AC UNIT 35 OCCUPANY SENSORS RE-WORK LIGHTING LAYOUT THROUGHOUT 1 POWER TO HEAT PUMP 25 POWER TO VAV PER 2008 NEC (OFFICE SPACE)"},{"number":"438266","date":"2012-12-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-04-20","scope":"1 AUX POWER SUPPLY 2 SMOKE DETECTORS 35 SPEAKER/STROBES 2 STROBES AS PER 2008 NEC & NFPA 72 (COMMERCIAL)"},{"number":"447011","date":"2013-01-08","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-04-15","scope":"RELOCATE (147) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT FITOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"444603","date":"2013-01-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-04-27","scope":"REMOVE & RELOCATE 4-SPEAKER-STROBE FIRE ALARM DEVICES AS PER NEC 2008 & NFPA 72 (COMM)"},{"number":"450479","date":"2013-02-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-08-15","scope":"FOR STRUCTURAL ALTERATIONS ON 13TH FLOOR AS PER PLANS."},{"number":"450892","date":"2013-03-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-07-20","scope":"FURNISH AND INSTALL NECESSARY 200A 3 PHASE 4 WIRE FEEDER FOR NEW UPS AND PROVIDE ONE 100A 480V FEED TO NEW 75KVA TRANSFORMER INSTALL BYPASS SWITCH PROVIDED BY OTHERS PER 2008 NEC (COMMERCIAL)"},{"number":"454439","date":"2013-03-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-12-02","scope":"INTERIOR DEMOLITION AND ALTERATIONS IN THE 11TH THROUGH 14TH FLOORS OF AN EXISTING BUILDING PER PLANS. ALL SPECIAL INSPECTION REPORTS TO BE FURNISHED TO FIELD INSPECTOR. SEPARATE PERMITS REQUIRED FOR ALL FIRE SUPPRESSION, MECHANICAL, ELECTRICAL AND PLUMBING WORK."},{"number":"457215","date":"2013-03-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (2) 40A, 208V SINGLE-PHASE CIRCUITS FOR ELECTRIC CAR CHARGERS IN PARKING GARAGE IN ACCORDANCE WITH 2008 NEC"},{"number":"460099","date":"2013-03-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-12-02","scope":"RELOCATING 561 SPRINKLERS ON THE 11TH TO THE 14TH FLOOR AT ONE LIBERTY PLACE"},{"number":"457876","date":"2013-04-08","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-12-02","scope":"FURNISH & INSTALL 11 KITCHEN SINKS, 5 WC, 6 LAVS, 2 SHOWERS, 11 FLOOR DRAINS, CONNECT TO EXISTING SERVICES (OFFICE BLDG)"},{"number":"462038","date":"2013-04-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-05-15","scope":"INTERIOR ALTERATIONS FOR STAIRWAY ENCLOSURES TO INCLUDE THE FOLLOWING STRUCTURAL WORK: INTERIOR DEMOLITION, NEW STEEL BEAMS WITH METAL DECK AND CONCRETE SLAB. FIRE RESISTANCE RATING CONSTRUCTION FOR STAIRWAY ENCLOSURE TO BE MAINTAINED. ALL WORK & SPECIAL INSPECTIONS SHALL BE IN ACCORDANCE WITH APPROVED PLANS."},{"number":"459978","date":"2013-04-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-08-17","scope":"WIRING OF DEVICES & LTS, SERVICE PANEL EXISTING TO BE REUSE, F/A ROUGH WIRE & TDERM OF FIELD DEVICES FINAL CONNECTION & CERT BY LANDLORD F/A VENDOR(*ADDITIONAL PERMIT REQUIRED FOR FA WORK*)AS PER NEC 2008 & NFPA 72 (COMM)"},{"number":"458535","date":"2013-05-09","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-12-02","scope":"FOR DEMOLITION OF EXIT. HVAC SYSTEM & ASSOCIATED DUCTWORK & EQUIPMENT & FOR INSTALLATION OF (479) GRILLES, REGISTERS, & DIFFUSERS (GRDS), (31) FAN TERMINAL UNITS (FTUS), THREE (3) CEILING MOUNTED HEAT PUMP (HP) UNITS, & ALL ASSOCIATED SUPPLY, EXHAUST, & RETURN DUCTWORK W. PLENUM CEILING FOR TIE-IN TO EXISTING HVAC SYSTEM SERVING EXIST. HIGH-RISE MIXED USE OFFICE BUILDING."},{"number":"467606","date":"2013-05-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-04-30","scope":"INSTALL 1252 CAT 6 PLENUM CABLES FOR VOICE AND DATA AND 32 CABLES FOR CAMERA AND CARD READERS.INSTALLATION TO COMPLY WITH ARTICLES 300.21, 725 & 800 OF THE 2008 NEC."},{"number":"462581","date":"2013-07-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-12-26","scope":"RENOVATION EXIST GLENMEDE TENANT SPACE INSTALL 1805-FIXTUES, 510-WALL SE, 657-RECPTS, 54-HVAC POWER, 52-FURNITURE FEED, 3-208/120V & 60AMP PANEL AS PER DRAWING AS PER NEC 2008 (COMM)"},{"number":"482800","date":"2013-07-12","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2013-07-12","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY FOR FLOORS 11 AND 13 ONLY."},{"number":"483925","date":"2013-07-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-02-21","scope":"INTERIOR ALTERATIONS AS PER PLAN."},{"number":"484031","date":"2013-07-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-02-21","scope":"FURNNISH AND INSTALL ONE VAV BOX, DUCTWORK AND FOUR AIR DEVICES AS PER PLANS."},{"number":"485797","date":"2013-07-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-27","scope":"REMOVE AND RELOCATE (2) 2X4 LIGHT FIXTURES, 2 OCCUPANCY SENSOR SWITCHES & 2 FLOOR BOXES TO ACCOMMODATE NEW OFFICE CONFIGURATION PER 2008 NEC (OFFICE SPACE)"},{"number":"488171","date":"2013-08-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-01-06","scope":"6-2X2 DIR/INDIR BASKET T8 LTS, 1 EXIT LT, 5 SINGLE POLE SWITHES, 1 CEIL MNTD OCCUPANCY SENSORS, 1 LOGO SIGN FEED W/ TIME CLOCK, 2 DUP REC CEILING MNTD, 1 QUAD REC, 1 PROJ FEED, 1 VAV FEED UP TO 12KW W/ 3PH DISCNCT AS PER 2008 NEC(OFFICE BLDG)AMEND PERMIT 485440"},{"number":"483215","date":"2013-08-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-09-03","scope":"FOR INTERIOR ALTERATIONS TO CONVERT ONE OFFICE INTO TWO OFFICES AS PER PLANS."},{"number":"490084","date":"2013-08-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-02-21","scope":"RELOCATE 4 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"490961","date":"2013-08-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-04-09","scope":"INSTALLATION OF LOW VOLTAGE CAT6 TELECOMMUNICATION CABLE AS PER 2008 NEC (OFFICE SPACE)"},{"number":"497586","date":"2013-10-30","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-05-01","scope":"AMEND PERMIT NUMBER 483925, TO INCLUDE FRAMING STRUCTURAL WORK, AS PER PLANS."},{"number":"481735","date":"2013-11-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-12-26","scope":"RENO TO EXISTING GLENMEDE TENANT SPACE. ITNSTALL 54 STROBES,65 HORN/STROBES,21 SMOKES,8 PULL STATIONS,5 HEAT DETECTORS, AND 2 DUCT DETECTORS AS PER 2008 NEC AND NFPA72 (OFFICE BLDG)"},{"number":"513346","date":"2014-01-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-06-11","scope":"REPLACE EXISTING FINISHES 6TH & 7TH FLOORS CORRIDORS, INCLUDING CONSTRUCTION OF DEMISHING WALLS ON 7TH FLOOR AND CONSTRUCTION OF COMMON AREA ADA TOILET ROOM ON 6TH & 7TH FLOOR."},{"number":"520310","date":"2014-02-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-06-11","scope":"INSTALL 2 NEW WATER CLOSETS,2 NEW SINKS ALONG WITH ASSOCIATED SANITARY,VENT AND WATER PIPING AND REPLACE 2 EXISTING DRINKING FOUNTAINS (OFFICE BLDG)"},{"number":"521970","date":"2014-02-28","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-06-13","scope":"SELECTIVE DEMO OF NON-LOAD BEARING PARTITIONS, ACOUSTIC CEILING SYSTEM, MILLWORK, ETC. 28000 SQUARE FEET, INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILINGS ONLY. NO OTHER WORK ALLOWED UNDER THIS PERMIT. NO STRUCTURAL CHANGES. MUST MAINTAIN ALL CODE REQUIRED FIRE RATING ON WALL AND FLOOR/CEILING ASSEMBLIES. THREE SETS OF PLANS DRAWN TO PROFESSIONAL QUALITY ARE TO BE SUBMITTED FOR REVIEW AND APPROVAL BY THE DEPARTMENT BEFORE WORK ON RENOVATION STARTS. CONTACT STREETS DEPARTMENT FOR DUMPSTER PERMIT AND FOOTWAY CLOSURE PERMITS."},{"number":"524949","date":"2014-03-18","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-09-30","scope":"RELOCATE (91) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE THE NEW TENANT LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"524959","date":"2014-03-18","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-09-30","scope":"RELOCATE (21) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW TENANT LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"515063","date":"2014-03-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-12-16","scope":"6TH FL REMOVE EXISTING 1X4 & INSTALL 32- NEW 2X2, RECONNECT TO EXISTING CKTS, 7TH FL REMOVE EXISTING 1X4 & INSTALL 21-NEW 2X2, ADD NEW PANEL & METER & REWIRE EXISTING TRANSFORMER AS PER NEC 2008 (OFFICE BLDG)**SEE LOG**"},{"number":"527599","date":"2014-03-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-09-06","scope":"RELOCATE 2-FURNITURE FEEDS, 4-DUPLEX RECPTS, 1-POKE-THRU, 3-2X4 LIGHTS TO ACCOMMODATE NEW LAY OUT (OFFICE SPACE)"},{"number":"524685","date":"2014-03-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-08-15","scope":"INTERIOR ALTERATIONS AND DEMO, UPGRADES TO FINISHES AND FURNISHINGS, RECONFIGURATION OF EXISTING OFFICE TENANT SPACE, NEW PARTITIONS, INCLUDING MECHANICAL ALTERATIONS OF RELOCATING, REPLACING CEILING DIFFUSERS, GRILLES FOR CEILING GRID RECONFIGURATION AS PER PLANS AND SPECS. ADDITIONAL PERMITS REQUIRED: ELECTRICAL, SPRINKLERS."},{"number":"524503","date":"2014-04-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-01-21","scope":"LEVEL II ALTERATION INCLUDE SLAB REMOVAL FOR COMMUNICATING STAIR **SEPARATE MECHANICAL, ELECTRICAL AND PLUMBING PERMITS IS REQUIRED**"},{"number":"525641","date":"2014-04-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"INTERIOR ALTERATIONS TO REMOVE 1 COPY ROOM AND RECONFIGURE EXISTING CONFERENCE ROOM TO ACCOMODATE NEW 3 WORKSTATIONS"},{"number":"530058","date":"2014-04-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-05-28","scope":"RELOCATE 9 SPRINKLERS ON THE 43RD FLOOR OF CITIBANK AT ONE LIBERTY PLACE"},{"number":"530103","date":"2014-04-14","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-06-10","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 7TH FLOOR ONLY."},{"number":"531654","date":"2014-04-22","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"DEMOLITION OF INTERIOR NON-BEARING PARTITIONS AND CEILINGS ONLY"},{"number":"531799","date":"2014-04-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-01-04","scope":"REMOVE DATA/VOICE/AUDIO CABLING FROM WALLS BEING DEMOLISHED & RELOCATE IN NEW WALLS."},{"number":"532366","date":"2014-04-25","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-11-14","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 26TH FLOOR ONLY."},{"number":"532980","date":"2014-04-29","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-11-14","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 24TH FLOOR ONLY."},{"number":"533594","date":"2014-04-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-10-31","scope":"RELOCATION OF 3 SPRINKLER HEADS."},{"number":"533859","date":"2014-05-01","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-28","scope":"RELOCATE 4 DIFFUSERS"},{"number":"529941","date":"2014-05-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-08-26","scope":"INSTALL 3 POWER POLES FOR SYSTEM FURNITURE,16 DUPLEX RECEPTACLES,PER TO AC UNIT & RELOCATE (11) 2X4 LIGHT FIXTURES TO ACCOMMODATE NEW LAYOUT PER 2008 NEC (OFFICE SPACE)"},{"number":"537062","date":"2014-05-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-09-16","scope":"RELOCATE (192) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"537639","date":"2014-05-20","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-09-18","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS 21ST FLOOR ONLY."},{"number":"531234","date":"2014-05-22","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-05-12","scope":"INSTALL 150 CATEGORY 6 CABLES,(1)25 PAIR DEMARCATION EXTENSION AND (2)12 STRAND FIBER OPTIC CABLES PER 2008 NEC. INSTALLATION TO COMPLY WITH ARTICLES 300.21, 300.22, 770.3 & 800 OF THE 2008 NEC."},{"number":"538978","date":"2014-05-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-09-06","scope":"REMOVE AND RELOCATE 1 SPEAKER STROBE PER 2008 NEC & NFPA 72(OFFICE SPACE)"},{"number":"537644","date":"2014-05-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-09-16","scope":"HVAC INCLUDING DUCTWORK AND MECHANICAL EQUIPMENT AS PER PLANS. 228 REGISTERS/DIFFUSERS."},{"number":"537602","date":"2014-06-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"LEVEL II INTERIOR ALTERATIONS TO OFFICE SPACES ON 7TH FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**"},{"number":"534148","date":"2014-06-13","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-11-14","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 27TH FLOOR ONLY."},{"number":"536426","date":"2014-06-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-09-06","scope":"INSTALL 2 FIRE ALARM STROBES AND RELOCATE 7 FIRE ALARM STROBES PER 2008 NEC & NFPA 72 (OFFICE SPACE)"},{"number":"537122","date":"2014-06-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-09-27","scope":"INSTALL NEW LIGHTING AND POWER AS PER 2008 NEC (CC DISTRICT) INSTALL FIRE ALARM DEIVCES THROUGH OUT SPACE AS PER NFPA72"},{"number":"543760","date":"2014-06-23","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-08-15","scope":"INSTALLATION OF WASTE AND VENT, DOMESTIC HOT AND COLD PIPING, SINK"},{"number":"545701","date":"2014-06-26","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-07-28","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 28TH FLOOR ONLY."},{"number":"539198","date":"2014-06-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-05-27","scope":"FOR ALTERATION TO EXISTING AUTOMATIC SPRINKLER SYSTEM W. EXIST. FIRE PUMP & BACKFLOW PREVENTION (BFP) ASSEMBLIES TO PROVIDE DOUBLE-ACTION PREACTION SYSTEM FOR PREVIOUSLY APPROVED DATA CENTER WITHIN AN EXIST. MIXED-USE HIGH RISE OFFICE BUILDING. AUTOMATIC SPRINKLER SYSTEM INSTALLATION IN ACCORDANCE WITH NFPA 13."},{"number":"538350","date":"2014-06-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"F&I 102 CAT6 PLENUM CABLES ON 7TH FL,206 CAT6 PLENUM CABLES ON 8TH FL,96 CAT6 PLENUM CABLES SERVER ROOM,12 STRANDS OF FIBER BETWEEN FLOORS 75FT PULL. INSTALLATION TO COMPLY WITH ARTICLES 300.21, 300.22, 770 & 800 OF THE 2008 NEC."},{"number":"546562","date":"2014-07-01","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2014-07-01","scope":"FOR THE CHANGE OF USE OF THE THIRD FLOOR TO PERSONAL SERVICES. NO CHANGE IN HEIGHT OR AREA OF EXISTING STRUCTURE. NO SIGNS ON THIS APPLICATION."},{"number":"543222","date":"2014-07-01","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-08-07","scope":"LEVEL II INTERIOR ALTERATIONS AS PER PLAN."},{"number":"537660","date":"2014-07-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-09-16","scope":"FURNISH AND INSTALL 3 KITCHEN SINKS,3 FLOOR DRAINS,3 LAVS,1 WATER CLOSET AND 1 SHOWER AND CONNECT TO EXISTING SERVICE (OFFICE BLDG)"},{"number":"540856","date":"2014-07-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-12-23","scope":"INSTALLATION OF AN AUTOMATIC CLEAN AGENT FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2001 AS PER PLANS."},{"number":"548657","date":"2014-07-11","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-01-24","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 23RD FLOOR ONLY."},{"number":"549709","date":"2014-07-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"RELOCATE 36 HEADS - 7TH FLOOR"},{"number":"541133","date":"2014-07-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"LEVEL II INTERIOR ALTERATION OF NEW OFFICE SPACE ON FLOORS 21 THROUGH 28 FOR COZEN O'CONNER"},{"number":"542667","date":"2014-07-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-02-11","scope":"ALTERATIONS TO EXISTING SPRINKLER SYSTEM TO INCLUDE COVERSION OF A PRE-ACTION SYSTEM TO EXISTING NFPA 13 WET SYSTEM."},{"number":"552846","date":"2014-07-31","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-03-06","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 22ND FLOOR ONLY."},{"number":"552255","date":"2014-08-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"FURNISH AND INSTALL HVAC SYSTEM, AS PER PLANS AND SPECS, INSTALLATION OF 233 FAN TERMINAL UNITS ALONG WITH 2 WATER SOURCE HEAT PUMPS MECHANICAL PIPING, ACCESSORIES."},{"number":"551480","date":"2014-08-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-09-01","scope":"FURNISH AND INSTALL NEW LIGHTING AND RECEPTS FOR THE TENANT FIT OUT, INSTALL 3725 LIGHT FIXTURES, 1617 SWITCHES AND RECEPTS, 33 FURNITURE CONNECTIONS, EXISTING PANELS WILL BE REUSED, 12 NEW PANELS & 3 TRANSFORMERS, LIGHTING CONTROL SYSTEMS AS PER 2008 NEC (CC DISTRICT)"},{"number":"550762","date":"2014-09-09","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"SANITARY, VENT AND DOMESTIC WATER CONNECTED TO EXISTING SERVICES, NEW PIPE RUN FOR NEW TENANT FIT OUT, 15 WATER CLOSET, 17 LAVY SINKS, 2 URINALS, 2 SHOWERS, 14 SINKS, 9 WATER COOLERS, 7 WASHING MACHINES, 7 FOLLR DRAINS AND 12 FLOOR SINKS"},{"number":"555980","date":"2014-09-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-10-23","scope":"FOR THE CREATION OF A VIDEO CONFERENCE ROOM ON THE 30TH FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING. WORK INCLUDES NEW INTERIOR NON-BEARING PARTITIONS, FINISHES AND FURNITURE. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND FIRE SUPPRESSION SYSTEMS."},{"number":"562132","date":"2014-09-16","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-09-19","scope":"TEMPORARY CO FOR 7TH AND 8TH FLOORS"},{"number":"562957","date":"2014-09-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-11-13","scope":"INSTALL ONE POKE-THRU AND CAT5E TELE/DATA WIRING WITH LONGEST RUN OF 10INCHES AND ONE DROP AS PER 2008 NEC (CC DISTRICT)"},{"number":"555830","date":"2014-09-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 59 CARD READER SYSTEMS WITH LOW VOLTAGE ELECTIRC LOCKS ON 7TH FLOOR STE A1&A2 AND , 21ST TO 28TH FLOORS USING PLENUM RATED CABLE CMP/FT6 WIHT FIRE RELEASE (ALL LOW VOLTAGE <30V) AS PER 2008 NEC (CC DISTRICT)"},{"number":"568495","date":"2014-10-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-06-15","scope":"RELOCATE 903 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"567416","date":"2014-11-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-09-01","scope":"FURNISH AND INSTALL NEW FIRE ALARM SYSTEM FOR THE TENANT FIT-OUT AS PER NFPA72 (CC DISTRICT)"},{"number":"574683","date":"2014-11-17","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-01-14","scope":"INTERIOR DEMO OF NON-LOAD BEARING RENOVATIONS"},{"number":"574680","date":"2014-11-17","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-03-25","scope":"INTERIOR DEMO OF NON-LOAD BEARING RENOVATIONS"},{"number":"576822","date":"2014-12-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-04-27","scope":"REMOVE EXISTING CORRIDOR LIGHT (20),FURNISH AND INSTALL NEW 2X2 FIXTURES (RECONNECT TO EXISTING0 AND REPLACE 12 EXISTING COVE LIGHTS AND ADD 1 SWITCH AND 1 RECEPTACLE PER 2008 NEC (OFFICE BLDG)"},{"number":"576788","date":"2014-12-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-05-07","scope":"FURNISH AND INSTALL 1 WATER CLOSET AND 1 LAV AND CONNECT TO EXISTING SANITARY,VENT AND DOMESTIC WATER (OFFICE SPACE)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"575446","date":"2014-12-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-09-17","scope":"LEVEL II ALTERATION INCLUDE NON LOAD BEARING RENOVATIONS"},{"number":"575439","date":"2014-12-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-03-25","scope":"LEVEL II ALTERATION INCLUDE NON LOAD BEARING RENOVATIONS"},{"number":"577652","date":"2014-12-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-03-25","scope":"RELOCATE 5 DIFFUSERS"},{"number":"577653","date":"2014-12-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-03-25","scope":"RELOCATE 3 DIFFUSERS"},{"number":"578959","date":"2014-12-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-04-27","scope":"REMOVE EXISTING CORRIDOR LIGHTS F&I 13-NEW 2X2 FIXTURES RECONNECT TO LEXISTING & REMOVE & REINSTALL 4-EXITS AS PER NEC 2008 (OFFICE BLDG) CC DISTRICT"},{"number":"578667","date":"2014-12-17","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2014-12-17","scope":"USE REGISTRATION PERMIT FOR TILT EXPERIENCE / OBSERVATION DECK WITH ASSOCIATED QUEUE AND MERCANTILE AREAS PARTIAL 1ST & 2ND, ENTIRE 57TH FLOOR"},{"number":"582865","date":"2015-01-06","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-03-25","scope":"RELOCATE 27 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"583920","date":"2015-01-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-08-07","scope":"RELOCATE 61 SPRINKLER HEADS (COMMERICAL)"},{"number":"585373","date":"2015-01-20","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-02-10","scope":"TO AMEND PERMIT #572401 TO CORRECT THE ADDRESS FROM 1600 MARKET STREET (PNC BUILDING) TO 1650 MARKET STREET (2 LIBERTY PLACE)."},{"number":"586318","date":"2015-02-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-08-07","scope":"HVAC INCLUDING DUCTWORK AS PER PLANS."},{"number":"586418","date":"2015-02-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-10-02","scope":"F&I FIRE ALARM EQUIPMENT PER 2008 NFPA (COMMERCIAL)"},{"number":"584366","date":"2015-02-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-10","scope":"F&I LIGHTING AND POWER PER 2008 NEC (COMMERCIAL)PANEL R1 SHALL BE FROM 30KVA TRANSFORMER THROUGH A 100A CIRCUIT BREAKER ON 30KVA TRANSFORMER SECONDARY."},{"number":"586335","date":"2015-02-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-08-07","scope":"ONE LIBERTY PLACE - 3RD & 4TH FLOORS - FITNESS CENTER PLUMBING ALTERATIONS - INSTALLATION WILL COMPLY WITH THE APPROVED PLANS AND THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"588492","date":"2015-02-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-02-02","scope":"52 NEW CONDO UNITS IN EXISTING BUILDING, SANITARY AND DOMESTIC WATER CONNECTIONS TO EXISTING SERVICES WITHIN BUILDING, NEW PLUMBING FIXTURFES - WORK IN COMPLIANCE WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"593910","date":"2015-03-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-09-24","scope":"RELOCATE THREE DIFFUSERS EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"596681","date":"2015-03-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RELOCATE FIRE STROBE FROM CORRIDER WALL TO NEW ADA BATH WALL MOVE APPROX 12\"- NOT NEW WIRING OR STROBE REUSE EXISTING AS PER NFPA 72"},{"number":"600557","date":"2015-04-06","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-07-17","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"580591","date":"2015-04-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-11-04","scope":"INTERIOR ALTERATIONS AT PORTION OF FIRST FLOOR, SECOND FLOOR AND THROUGHOUT ENTIRE 57TH FLOOR PER PLANS. WORK TO INCLUDE NEW EXTERIOR DOOR AT COURTYARD, PARTITIONS, FINISHES, ACCESSIBLE SERVICE COUNTERS AND BATHROOM FACILITIES FOR OBSERVATION DECK. ALL ELEVATOR WORK REQUIRES APPROVAL FROM PENNSYLVANIA DEPARTMENT OF LABOR AND INDUSTRY. SEE PERMIT # 580592 FOR STRUCTURAL WORK ASSOCIATED WITH \"TILT EXPERIENCE\" AND MECHANICAL PERMIT # 580604. CERTIFICATE OF OCCUPANCY FOR 1ST/2ND FLOOR UNDER PERMIT # 601169; CERTIFICATE OF OCCUPANCY AND LAWFUL OCCUPANCY SIGN FOR 57TH FLOOR UNDER PERMIT # 601170. SEPARATE PERMITS REQUIRED FOR ALL ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"601169","date":"2015-04-28","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-01-29","scope":"CERTIFICATE OF OCCUPANCY FOR PARTIAL CHANGE IN OCCUPANCY IN A PORTION OF THE FIRST AND SECOND FLOORS OF AN EXISTING HIGH-RISE BUILDING. SEE PARENT PERMIT # 580591 FOR ASSOCIATED ALTERATIONS."},{"number":"580604","date":"2015-04-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-03","scope":"MECHANICAL WORK ASSOCIATED WITH FITOUT FOR NEW 57TH FLOOR OBSERVATION DECK AND ASSOCIATED FIRST/SECOND FLOOR SUPPORT SPACES. PARTIAL DEMOLITION OF EXISTING DUCTWORK, FAN COIL UNITS AND ASSOCIATED PIPING. INSTALLATION OF NEW DUCTWORK, GRILLES, REGISTERS, DIFFUSERS, FAN TERMINAL UNITS, FAN COIL UNITS, HEAT PUMPS AND WATER COOLED CONDENSING UNIT PER PLANS. SEPARATE PERMITS REQUIRED FOR ALL ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"601170","date":"2015-04-28","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-05-04","scope":"CERTIFICATE OF OCCUPANCY AND LAWFUL OCCUPANCY SIGN FOR COMPETE CHANGE OF OCCUPANCY IN THE 57TH FLOOR OF AN EXISTING HIGH-RISE BUILDING TO AN OBSERVATION DECK WITH \"TILT EXPERIENCE\". SEE PARENT PERMITS # 580591 AND # 580592 FOR ASSOCIATED ALTERATIONS."},{"number":"603235","date":"2015-05-08","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-11-03","scope":"FURNISH & INSTALL 6-WC-1, 3-WC-2, 5-LAVS-1, 2-SK-1, 2-UR-1, 3-FD-1,1-MR-1 & 1-EWC-1 CONNECT TO EXISTING SANITARY, VENT & DOMESTIC WATER (MIXED USE) THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"611233","date":"2015-05-19","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-11-03","scope":"RELOCATE 124 SPRINKLERS ON THE 1ST AND 2ND FLOOR OF ONE LIBERTY PLACE OBSERVATORY-TILT"},{"number":"612180","date":"2015-05-22","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-05-27","scope":"TCO FOR 21ST FLOOR INT FIT OUT OF NEW OFFICE SPACE FOR COZEN O'CONNER"},{"number":"597509","date":"2015-06-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-10-01","scope":"FOR PRESCRIPTIVE ALTERATIONS AT WITHIN EXIST. MIXED-USE HIGH-RISE MULTI-FAMILY & COMMERCIAL BUILDING TO INCLUDE ERECTION OF PARTITION WALLS FOR OFFICE SPACES, TENANT SEPARATION WALLS, & OPEN OFFICE SPACE & INSTALLATION OF SUSPENDED CEILING SYSTEM; WORK AREA TO BE FULLY SPRINKLERED. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, & FIRE SUPPRESSION WORK."},{"number":"620306","date":"2015-06-25","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-07-07","scope":"TCO FOR OFFICE NUMBERS 3715, 3716, & 3717."},{"number":"563954","date":"2015-07-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INTERIOR ELECTRICAL ALTERATIONS FOR TENANT (COZEN O'CONNER) - FLOORS 7 & 21 THRU 28 - (23)WORK AREA OUTLETS CONSISTING OF (42)CAT6 PLENUM CABLE - NOTE: INSTALLATION TO COMPLY WITH ARTICLES 300.21, 300.22 & 725 OF THE 2008 NEC - NOTE: ADDRESS CORRECTED ON 07.02.2015"},{"number":"608810","date":"2015-07-07","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-08-12","scope":"AMEND PERMIT #580604 REMOVAL AND RELOCATION OF SOME DUCT WORK AS PER PLAN."},{"number":"608820","date":"2015-07-07","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-08-12","scope":"AMEND PERMIT #580591. NEW PROPOSED LOCATION FIR THE TURNSTILES ON THE 2ND FLOOR."},{"number":"615668","date":"2015-07-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-12","scope":"FURNISH & INSTALL NECESSARY POWER & LIGHTING & TELE/DATA WIRING (158) TOTAL DROPS LONGEST RUN IS 200' AS PER NEC 2008 CC DISTRICT"},{"number":"580592","date":"2015-07-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"STRUCTURAL WORK ASSOCAITED WITH \"TILT\" AMUSEMENT EXPERIENCE (MOVEABLE GLASS ENCLOSURE AT EXTERIOR WALLS ON SOUTHWEST CORNER OF 57TH FLOOR OF EXISTING HIGH RISE BUILDING. WORK INCLUDES STRUCTURAL STEEL INSTALLATIONS, MULTI-LAYER TEMPERED ENCLOSURE WITH \"SENTRYGLASS\" LAMINATE, HANDRAILS, INSULATION, HYDRAULIC ACTUATING SYSTEM / ASSOCAITED SUPPORTS, AND FINISHES PER PLANS. ALL SPECIAL INSPECTION REPORTS TO BE FURNISHED TO DEPARTMENT FIELD INSPECTOR **SPECIAL INSPECTORS TO BE NAMED AND REVIEWED UNDER SEPARATE AMENDED PERMIT APPLICATION PRIOR TO START OF WORK REQUIRING INSPECTIONS SELECTED IN SCHEDULE** ALTERATIONS APPROVED UNDER PERMIT # 580591, C/O UNDER PERMIT # 601170. SEPARATE PERMITS REQUIRED FOR ALL FS / MECH / ELEC / PLUMB WORK."},{"number":"612960","date":"2015-07-23","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-08-15","scope":"AMEND PERMIT # 537602 FOR INTERIOR FITOUT OF OFFICE AND ADMINISTRATIVE SPACE, OFFICE MAIL/COPY SUPPORT AREA AND SHOWER ROOMS TO REFLECT AS BUILT CONDITIONS AS PER APPROVED PLANS."},{"number":"612958","date":"2015-07-23","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-08-15","scope":"AMEND PERMIT # 541133 FOR INTERIOR FITOUT OF NEW OFFICE SPACE ON FLOORS 21 THROUGH 28. SCOPE OF WORK TO INCLUDE MINOR CHANGES TO FLOOR LAYOUT, DOORS, PARTITIONS, AND ALL OTHER WORK AS PER APPROVED PLANS. SEE AP# 541133 FOR CERTIFICATE OF OCCUPANCY AND SUPPLEMENTAL DOCUMENTS."},{"number":"627860","date":"2015-07-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-09-16","scope":"RELOCATE (23) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"627553","date":"2015-07-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 6 SPEAKERS, 1 AUDIO PLATE, 1 MUSIC RACK, 1 WALL CONTROL & 13 RF CONTROL PLATES."},{"number":"597513","date":"2015-08-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-10-01","scope":"DUCTWORK, REGISTERS/DIFFUSERS, MECHANICAL UNITS, AND ALL INCIDENTALS (HVAC) AS PART OF RENOVATION PROJECT."},{"number":"624750","date":"2015-08-04","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-02-24","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING BUSINESS AND PROFESSIONAL OFFICE ON THE 35TH FLOOR OF AN EXISTING HIGH RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"629868","date":"2015-08-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-03-15","scope":"INSTALLATION OF CUSTOMER SUPPLIED MATERIALS TO SUPPORT COMMUNICATION CONNECTIVITY TO 38 STATIONS"},{"number":"630012","date":"2015-08-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-10-01","scope":"INSTALLATION OF KITCHEN SINK AND OPEN SITE DRAIN(INDIRECT WASTE) WITH TRAP PRIMER; CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC WATER"},{"number":"623190","date":"2015-08-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-23","scope":"INSTALL 30 SPEAKER/STROBES,9 STROBES,12 SMOKE DETECTORS AND 1 NAC PANEL PER NFPA 72 (OFFICE SPACE)"},{"number":"633304","date":"2015-08-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-02-11","scope":"RELOCATE 148 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"633495","date":"2015-09-09","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-02-11","scope":"ROUGH-IN PLUMBING FOR: 2- SINKS, 1- WATER COOLER, 2- WATER CLOSETS, 2- LAVS, 1- FLOOR DRAIN. SEPARATE ELECTRIC PERMIT REQUIRED FOR ANY ELECTRICAL WORK"},{"number":"632570","date":"2015-09-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-05","scope":"FURNISH AND INSTALL (7) CEILING SPEAKERS-STROBES, (2) WALLS STROBES AND 1 PANEL AS PER NFPA 72 AND DRAWINGS"},{"number":"641164","date":"2015-09-24","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-10-06","scope":"C.O."},{"number":"635866","date":"2015-10-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-11-03","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 ON THE 57TH FLOOR AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"638461","date":"2015-10-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-12-28","scope":"LEVEL II ALTERATION INCLUDE SELECTIVE DEMOLITION, NEW INTERIOR FINSIHES AS PER PLAN."},{"number":"643925","date":"2015-10-08","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-12-23","scope":"RELOCATE (38) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"641876","date":"2015-10-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-02-11","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO INCLUDE FURNISHING AND INSTALLATION OF NEW VAV BOXES, DOOR, AND AIR DEVICES FOR NEW OFFICE LAYOUT ON 35TH FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS."},{"number":"644301","date":"2015-10-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-23","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM FOR 30TH FLOOR OFFICE SPACE TO INCLUDE FURNISH AND INSTALL HVAC DUCT, VAV BOXES, AIR DEVICES FOR NEW LAYOUT AS PER APPROVED PLANS."},{"number":"647229","date":"2015-10-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-01-25","scope":"REPLACE EXISTING 20KW UPS WITH NEW 20KW UPS AS PER 2008 NEC (CC DISTRICT)"},{"number":"648027","date":"2015-11-03","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-12-23","scope":"30TH FLOOR (ONE LIBERTY PLACE) - M3 USA PLUMBING ALTERATIONS - INSTALL SINKS, SAFE WASTE RECEPTACLES, INDIRECT WASTE LINES FROM EQUIPMENT AND WATER SUPPLY PIPING TO FIXTURES/EQUIPMENT PROTECTED BY A METHOD LISTED IN TABLE 608.1 OF THE 2009 INTERNATIONAL PLUMBING CODE - EACH WATER SUPPLY TO EQUIPMENT (CM-1, IM-1, DW-1 AND THE REFRIGERATOR ICE MAKERS) MUST BE INDIVIDUALLY PROTECTED BETWEEN THE OUTLET AND CONTROL VALVE PER SECTION P-806.1.1 OF THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"650328","date":"2015-11-05","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-12-30","scope":"RELOCATE (5) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"650571","date":"2015-11-06","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2015-11-09","scope":"120 DAY TCO"},{"number":"635978","date":"2015-11-09","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"EXPIRED","completedDate":null,"scope":"AMEND BUILDING PERMIT # 580592 TO REFLECT CHANGES TO THE \"TILT\" FEATURE STRUCTURAL DESIGN PLANS, NEW SHEETS AND REVISIONS PER LETTER DATED AUGUST 24, 2015 FROM ROBERT C. SINN, P.E. OF THORNTON TOMASETTI. ALL SPECIAL INSPECTIONS SHALL PROCEED UNDER ORIGINAL PERMIT."},{"number":"635974","date":"2015-11-09","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2017-09-25","scope":"AMEND BUILDING PERMIT # 580591 TO REFLECT DESIGN CHANGES INCLUDING THE ADDITION OF A ONE (1) HOUR RATED SHAFT WALL ON THE 2ND FLOOR CORRIDOR AND THE REPLACEMENT/ADDITION OF THE SLOPED GLAZING SAFETY FILM PER MANUFACTURER'S INSTALLATION INSTRUCTIONS/SPECIFICATIONS AT CERTAIN AREAS OF THE 57TH FLOOR."},{"number":"643764","date":"2015-11-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-16","scope":"PROVIDE LABOR TO INSTALL 284 CATEGORY 6 PLENUM CABLE LOCATIONS.THE LONGEST CABLE RUN IS 275FT PER 2008 (OFFICE SPACE)"},{"number":"643654","date":"2015-11-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (30) DUPLEX RECEPTS, (10) DED DUP RECEPTS, (25) 2X4 FIXTURES, (60) DOWNLIGHTS, (8) EXIS SIGNS & (15) OCC SENSEORS. AS PER 2008 NEC (CC DISTRICT)"},{"number":"646833","date":"2015-11-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-03-30","scope":"FURNISH AND INSTALL 34 CAT6 PLENUM CABLES FOR VOICE AND DATA AS PER 2008 NEC (CC DISTRICT)"},{"number":"646657","date":"2015-11-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-02-23","scope":"INSTALL (11) SPEAKER/STROBES AND (10) STROBES.AS PER NFPA72 (CC DISTRICT)"},{"number":"646742","date":"2015-11-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION TO EXISTING TENANT SPACE,INSTALL 32 SPEAKER/STROBES AS PER NFPA72 (CC DISTRICT)"},{"number":"631807","date":"2015-12-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT, INTALL 390-LIGHT FIXTURES, 76-LIGHT SWITCHES, 1-LIGHTING CONTROL PANEL, 189-RECEPTS, 27-FURNITURE FEED, 30-EQUIPMENT FEED, 1-480/277 VOLT PANEL AS PER NEC 2008 CC DISTRICT"},{"number":"659662","date":"2016-01-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-06-17","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING BUSINESS AND PROFESSIONAL OFFICE ON THE 7TH FLOOR OF AN EXISTING HIGH RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"649523","date":"2016-01-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-10-08","scope":"ALTERATION: INTERIOR PLUMBING OF (1) RESIDENTIAL UNIT ON THE 57TH FLOOR OF A HIGH RISE BUILDING. - THE INSTALLATION WILL COMPY WITH THE PHILADEPHIA PLUMBING CODE, 2004"},{"number":"666531","date":"2016-02-09","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-06-14","scope":"INSTALLATION OF HVAC MECHANICALS, FAN TERMINAL UNITS, LINEAR AND CEILING DIFFUSERS, CONTROLS, MECHANICAL ACCESSORIES AS PER PLANS AND SCHEDULES."},{"number":"669457","date":"2016-02-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-06-14","scope":"RELOCATE (24) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"662750","date":"2016-02-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 84 CAT6 CABLE PLENUM NOT TO EXCEED 295, INSTALL NEW 48 PORT PATCH PANEL AND 2-24 PORT MODULAR PATCH PANEL ALL CABLE TO BE LABEL AND TESTED PER 2008 NEC (OFFICE SPACE)"},{"number":"670994","date":"2016-02-19","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-02-19","scope":"120 DAY TCO"},{"number":"673335","date":"2016-04-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-07-27","scope":"ADD 7 NEW DEVICES TO EXISTING FIRE PANEL PER NFPA 72. INSTALL 6 FURNITURE POWER FEEDS. 30 RECEPTACLES, 35 LAY-IN FIXTURES,25 DOWN LIGHTS,3 EXIT LIGHTS AND 9 WALL SWITCHES AND 3 CEILING SENSORS PER 2008 NEC (OFFICE SPACE)CC DISTRICT"},{"number":"684784","date":"2016-04-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-10-13","scope":"LEVEL II ALTERATIONS INCLUDES INTERIOR, NON LOAD BEARING WALLS AS PER PLAN.**SEPARATE PERMITS REQUIRED FOR M.E.P.S**"},{"number":"689197","date":"2016-05-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 1-20AMP CIRCUIT TO POWER 1 NEW ILLUMINATED SIGN AS PER 2008 NEC (CC DISTRICT) OTHER 2 SIGNS ARE NOT ILLUMINATED"},{"number":"690881","date":"2016-05-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-12-05","scope":"RELOCATE (8) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"691616","date":"2016-05-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-12-09","scope":"RELOCATE (1) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"690022","date":"2016-05-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-12-05","scope":"MECHANICAL ALTERATIONS AND NEW INSTALLATIONS TO HVAC SYSTEM, NEW DUCTWORK, DIFFUSERS, EQUIPMENT, MECHANICALS AS PER PLANS."},{"number":"690290","date":"2016-05-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-07-07","scope":"ALTERATIONS INCLUDES INSTALLATION OF GLASS LOBBY DOOR AS PER PLAN."},{"number":"690746","date":"2016-05-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-12-05","scope":"INSTALL 1- ADA WATER CLOSET AND 1- ADA WALL HUNG LAVATORY, CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC WATER"},{"number":"693397","date":"2016-06-06","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-06-14","scope":"FOR A TEMPORARY CERTIFICATE OF OCCUPANCY FOR THE 57TH FLOOR ON 6/22/2016 AT 8PM TO 6/23/2016 AT 10AM. SPECIAL EVENT AND FIRE WATCH TO COMPLY WITH ATTACHED CODE BULLETIN NO. A-1501."},{"number":"696789","date":"2016-06-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-06-08","scope":"FOR PRESCRIPTIVE ALTERATIONS FOR INTERIOR DEMOLITION, PARTITION WALL INSTALLATION & FINISH WORK FOR OFFICE SPACES INCLUDING OPEN WORK, CONFERENCE & KITCHENETTE SPACES; BUILDING IS FULLY SPRINKLERED. SEPARATE PERMIT REQ'D FOR ANY MECH., ELEC., PLUMB. & FIRESUPP WORK."},{"number":"702640","date":"2016-06-24","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-04-17","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. RELOCATE 147 SPRINKLERS ON THE 51ST AND 52ND FLOORS"},{"number":"692596","date":"2016-06-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-09-08","scope":"REMOVE EXISTING FLORESCENT LIGHT FIXTURES ON THE 30TH AND 31ST FL.,INSTALL 31-NEW FLORESCENT LIGHT FIXTURES,100FT LINEAR SOFFIT LIGHTS AND ALL TO RECONNECT TO EXISTING CIRCUITS AS PER 2008 NEC (CC DISTRICT) ADD 1-NEW HORN/STROBE ON 30TH FL ADA BATH AND 1-NEW HORN/STROBE ON THE 31ST FL ADA BATH AS PER NFPA72"},{"number":"705804","date":"2016-07-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-05-31","scope":"2- SINKS, 2- INDIRECT WASTE AND WATER HEATER... 51ST AND 52ND FLOORS"},{"number":"707509","date":"2016-07-14","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-08-05","scope":"120 DAY TCO"},{"number":"709839","date":"2016-07-25","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2017-07-17","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"704008","date":"2016-07-27","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-08","scope":"FOR MECHANICAL ALTERATIONS TO INCLUDE NEW REGISTERS/DIFFUSERS WITH ASSOCIATED DUCT WORK IN AN EXISTING STRUCTURE, AS PER APPROVED PLANS."},{"number":"705859","date":"2016-07-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-04-17","scope":"LEVEL II ALTERATION NON-LOAD BEARING RENOVATION TO INSTALL AN ACCESSIBLE TOILET ROOM AS PER PLAN.** SEPARATE PERMITS REQUIRED FOR M.E.P.S **"},{"number":"712490","date":"2016-08-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-02-27","scope":"RELOCATE 25 SPRINKLERS ON THE 6TH FLOOR-EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"714734","date":"2016-08-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-03-10","scope":"INSTALLATION OF 1 WATER CLOSET,1 LAVATORY AND 1 WATER COOLER (OFFICE SPACE)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"709057","date":"2016-08-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-10","scope":"PROVIDE LABOR TO INSTALL 131 UNIPRISE CATEGORY 6 PLENUM 4 PAIR LOCATIONS LONGEST CABLE RUN IS 275' AS PER 2008 NEC (CC DISTRICT)"},{"number":"718811","date":"2016-08-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL CIRCUITS FOR HVAC AND EXHAUST FAN AND INSTALL 2 DUPLEX RECEPTACLES PER 2008 NEC (SFD)CC DISTRICT"},{"number":"704187","date":"2016-09-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-08","scope":"RENONVATION TO EXISTING SPACE FOR NEW TENANT, INSTALL 677 LIGHT FIXTURES, 72 LIGHT SWITCHES, 90 RECEPTS, 7 FURNITURE FEEDS, 13 EQUIPMENT FEED AS PER 2008 NEC (CC DISTRICT)"},{"number":"710799","date":"2016-09-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-10","scope":"INSTALL 21-SPEAKER/STROBE, 2-STROBE, 6-MODULE & 2-AUXILLIARY POWER SUPPLY AS PER NFPA 72 CC DISTRICT"},{"number":"722714","date":"2016-09-19","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"EZ STANDARD LIMITED COMMERCIAL ALTERATIONS & REPAIRS- FOR THE LIMITED DEMOLITION AND COMMERCIAL ALTERATIONS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"709545","date":"2016-09-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-01-17","scope":"INSTALLATION OF NEW 5-TON SPLIT LIEBERT MIN-MATE A/C UNIT ON 6TH FLOOR & SPLIT DUCTLESS UNIT IN FIRE COMMAND CENTER ON 1ST FLOOR OF EXISTING HIGH RISE. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL OR PLUMBING WORK."},{"number":"723894","date":"2016-09-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION TO EXISTING SPACE, REMOVE AND REINSTALL 12-LIGHT FIXTURES,INSTALL 2-WALL FURNITURE FEED AND REUSE EXISTING CIRCUITS FROM DEMO AS PER 2008 NEC (CC DISTRICT)"},{"number":"717741","date":"2016-09-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-03-10","scope":"LEVEL TWO ALTERATIONS WITHIN EXISTING OFFICE SPACE, AS PER PLANS."},{"number":"730177","date":"2016-10-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-11-22","scope":"PLUMBING ALTERATIONS IN OCCUPANCIES OTHER THAN ONE-FOUR FAMILY DWELLINGS"},{"number":"722062","date":"2016-10-20","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-09-23","scope":"INSTALL 1 LIGHT FIXTURES,1 LIGHT SWITCH,2 RECEPTACLES PER 2008 NEC (OFFICE SPACE)CC DISTRICT INSTALL FIRE ALARM SPEAKER/STROBE PER NFPA 72"},{"number":"723432","date":"2016-10-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-04-17","scope":"FOR ALTERATIONS TO AN EXISTING MECHANICAL SYSTEM ON THE 51ST FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING. WORK TO INCLUDE NEW REGISTER/DIFFUSER AND SUPPLEMENTAL DUCTWORK AS SHOWN IN APPROVED PLANS."},{"number":"726358","date":"2016-11-01","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-10","scope":"FOR ALTERATIONS TO AN EXISTING MECHANICAL SYSTEM IN A HIGH-RISE OFFICE BUILDING TO CONFORM TO ALTERATIONS PERFORMED UNDER PERMIT #724679. WORK TO INCLUDE NEW REGISTERS/DIFFUSERS AND ALL SUPPLEMENTAL DUCTWORK AS SHOWN IN APPROVED PLANS."},{"number":"724679","date":"2016-11-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-08-10","scope":"FOR LEVEL II INTERIOR ALTERATIONS ON THE NINTH AND TENTH FLOORS OF AN EXISTING HIGH-RISE OFFICE BUILDING. WORK TO INCLUDE SELECTIVE DEMOLITION AND THE ERECTION OF INTERIOR NON-BEARING PARTITIONS, MILLWORK, AND FINISHES. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS."},{"number":"726801","date":"2016-11-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-12-12","scope":"RENOVATION TO EXISTING SPACE. INSTALL 2 LIGHT FIXTURES, 5 RECEPTACLES, 1 INSTA HOT POWER, RELAMP 138 LIGHT FIXTURES PER NEC 2008 (OFFICE SPACE)CC DISTRICT"},{"number":"733962","date":"2016-11-14","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-08-24","scope":"FOR THE INSTALLATION OF A DOORWAY FOR UNIT 5701 AS SHOWN PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"735375","date":"2016-11-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-05-10","scope":"REMOVE AND REPLACE ONE SINK IN LUNCH ROOM, CONNECT TO EXISTING PLUMBING ROUGH-IN."},{"number":"739817","date":"2016-12-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALLATION OF 19- DUPLEX CAT 5E PLENUM RATED CABLES ON 9TH & 10TH FLOORS, 24AWG.... IN ACCORDANCE WITH 2008 NEC"},{"number":"741697","date":"2016-12-07","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-12-19","scope":"T C O"},{"number":"737903","date":"2017-01-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-25","scope":"FURNISH 243 LIGHTING FIXTURES,27 SWITCHES & SENSORS,2 LIGHTING CONTROL PANELS,5 FURNITURE FEEDS,22 RECEPTACLES AND RE-USE EXISTING POWER PANELS PER 2008 NEC (OFFICE SPACE)CC DISTRICT"},{"number":"753956","date":"2017-01-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REPLACE 12 EXISTING CARD READERS AND ASSOCIATED SECURITY DEVICES AS PER 2008 NEC (CC DISTRICT)"},{"number":"756939","date":"2017-02-06","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2017-03-27","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"759865","date":"2017-03-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-07-29","scope":"LEVEL II ALTERATIONS TO INCLUDE STRUCTURAL WORK, INTERIOR DEMOLITION OF NON-LOAD BEARING PARTITIONS AS PER PLAN. **SEPARATE PERMIT IS REQUIRED FOR M.E.P.S**"},{"number":"764214","date":"2017-03-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-10-24","scope":"FOR LEVEL II INTERIOR ALTERATIONS ON THE 51ST OF AN EXISTING HIGH-RISE OFFICE BUILDING. WORK TO INCLUDE SELECTIVE DEMOLITION AND THE ERECTION OF INTERIOR NON-BEARING PARTITIONS, MILLWORK, AND FINISHES. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS."},{"number":"762495","date":"2017-03-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-25","scope":"INSTALL 3 FA SPEAKER STROBES AND 2 FA STROBES."},{"number":"766160","date":"2017-03-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-29","scope":"FOR MECHANICAL ALTERATIONS TO INCLUDE NEW REGISTERS/DIFFUSERS AND ASSOCIATED DUCT WORK, AS PER APPROVED PLANS."},{"number":"775974","date":"2017-04-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL (133) CATEGORY 5E PLENUM CABLES. FURNISH AND INSTALL (142) CATEGORY 6 PLENUM CABLES, FURNISH AND INSTALL (4) CATEGORY 6A PLENUM CABLES. AVERAGE CABLE PULL 175 FEET"},{"number":"764768","date":"2017-04-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-07-29","scope":"ALTERATIONS:INTERIOR PLUMBING;HIGH-RISE OFFICE BUILDING; 34 FLOOR -THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"776422","date":"2017-04-19","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-07-29","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"777299","date":"2017-04-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-10-25","scope":"REPLACE EXISTING PANTRY SINK"},{"number":"773500","date":"2017-05-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-29","scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT.INSTALL 460 LIGHTS FIXTURES,156 LIGHT SWITCHES178 RECEPTACLES,12 FURNITURE FEED,10 EQUIPMENT FEED PER 2008 NEC (OFFICE SPACE)INSTALL 55 FA DEVICE PER NFPA 72"},{"number":"772637","date":"2017-05-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-05","scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT.INSTALL 15 LIGHTS FIXTURES,13 LIGHT SWITCHES,36 RECEPTACLES,3 FLOOR RECEPTACLES,31 LIGHT FIXTURES PER 2008 NEC (OFFICE SPACE)INSTALL 3 SPEAKER/STROBE AND 2 STROBES PER NFPA 72"},{"number":"786753","date":"2017-05-25","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-08-10","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"785159","date":"2017-06-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-07","scope":"FURNISH AND INSTALL APPROX 96 CAT 5E PLENUM CABLES FOR VOICE AND DATA PER 2008 NEC (OFFICE SPACE)"},{"number":"793372","date":"2017-06-20","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2017-07-26","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"788909","date":"2017-06-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-09-29","scope":"LEVEL II ALTERATIONS OF COMMERCIAL OFFICE SPACE ON THE 38TH AND 39TH FLOOR. PROJECT INCLUDES NEW PARTITIONS FINISHES AND CEILING. ** SEPARATE PERMIT IS REQUIRED FOR M.E.P.S.**"},{"number":"798040","date":"2017-07-07","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-02-01","scope":"EZ INTERIOR DEMOLITION-INTERIOR, NON LOAD BEARING DEMOLITION FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"800197","date":"2017-07-17","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2017-11-08","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"802140","date":"2017-07-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-02-21","scope":"FOR INTERIOR ALTERATIONS OF ADA RESTROOM ON THE 31ST FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER PLANS, SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS."},{"number":"804025","date":"2017-08-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-09-29","scope":"DEMO EXISTING FLOOR DRAIN, INSTALL NEW FLOOR DRAIN. INSTALL HOT AND COLD WATER PIPING AND ELECTRIC WATER HEATER"},{"number":"805159","date":"2017-08-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-09-29","scope":"RELOCATING 18 SPRINKLER HEADS IN THE ONE LIBERTY BUILDING ON THE 39TH FLOOR"},{"number":"801820","date":"2017-08-09","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-29","scope":"HVAC, INCLUDING DUCTWORK AND MECHANICAL EQUIPMENT, AS PER PLANS (19) REGISTRERS/DIFFUSERS"},{"number":"806809","date":"2017-08-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-10-24","scope":"THIS IS AN OVER THE COUNTER PERMIT APPLICATION. WE WILL BE ROLCATING (22) SPRINKLERS ON THE 51ST FLOOR IN THE ONE LIB ERTY PLACE BUILDING, IN GOLKOW TECHNOLOGIES."},{"number":"800219","date":"2017-08-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-05","scope":"INSTALL LIGHT FIXTRUES & RELOCATE EXISTING LIGHTS AS NEEDED, NEW BRANCH CKT CONDUCTERS OFF NEW PNL IN MC CABLE FOR RECEPTS, 1-100AMP PANELFOR IT ROOM EQUIPMENT AS PER NEC 2008 & INSTALL NEW HORN/STROBE AS PER NFPA 72 CC DISTRICT"},{"number":"804911","date":"2017-08-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-04-30","scope":"INTERIOR NON-LOAD BEARING RENOVATIONS TO THE THIRD FLOOR TO CREATE A LOUNGE AND CONFERENCE SPACE ACCESSORY TO THE OFFICE TENANTS AS PER PLANS. SEPARATE PERMITS REQUIRED FOR M, E, P."},{"number":"811390","date":"2017-09-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-12-12","scope":"LEVEL II ALTERATION INCLUDES INTERIOR NON LOAD BEARING RENOVATIONS TO INSTALL A TURNSTYLE IN THE LOBBY."},{"number":"812102","date":"2017-09-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-16","scope":"FOR LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) ON THE 15TH FLOOR OF AN EXISTING OFFICE BUILDING TO INCLUDE DEMOLITION AND ERECTION OF PARTITION WALLS AND ALL ASSOCIATED FINISH WORK AS PER PLANS; BUILDING IS FULLY SPRINKLED, SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS."},{"number":"809498","date":"2017-09-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-29","scope":"ADDING 1- 2X2 LIGHT FIXTURE, 1 WALL MOUNTED OCCUPANCY SENSOR SWITCH, 1 -20AMP CIRCUIT FOR FUTURE HAND DRYER AS PER 2008 NEC (CC DISTRICT) ADD FIRE ALARM SPEAKER STROBE AS PER NFPA 72"},{"number":"812640","date":"2017-09-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-02-21","scope":"INSTALL 1- HANDI-CAP WATER CLOSET AND LAV. CONNECT TO EXISTING SANITARY AND WATER PIPING"},{"number":"816317","date":"2017-09-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-07","scope":"PHASE #1, 39TH FLOOR: 10 CAT 6 DATA DROPS, 2- RG6 CABLE LOCATIONS, REROUTE F20- DATA LOCATIONS, PHASE #2, BETWEEN 37TH & 39TH FLOORS: PULL PRE-TERMINATED 12 STRAND SAM FIBER (200' MAX RUN), AND 12 STRAND 50 MICRON (75' MAX RUN), 3- 25 PR CAT 5E CABLES- 200' MAX... PER 2008 NEC (HI-RISE)"},{"number":"819295","date":"2017-09-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-11-16","scope":"RELOCATE OF 32 EXISTING FIRE SPRINKLER HEADS ON 15TH FLR."},{"number":"819608","date":"2017-09-27","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-11","scope":"INTERIOR DEMOLITION PERMIT - FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. NO CHANGE TO EXISTING FIRE AND SAFETY SYSTEMS DURING THE INTERIOR DEMOLITION OF THE CORRIDORS IN THIS QUADRANT. SEPARATE PERMITS REQUIRED FOR ALTERATIONS, ELECTRIC, PLUMBING, HVAC & FSS."},{"number":"819604","date":"2017-09-27","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-11","scope":"INTERIOR DEMOLITION PERMIT - FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. NO CHANGE TO EXISTING FIRE AND SAFETY SYSTEMS DURING THE INTERIOR DEMOLITION OF THE CORRIDORS IN THIS QUADRANT. SEPARATE PERMITS REQUIRED FOR ALTERATIONS, ELECTRIC, PLUMBING, HVAC & FSS."},{"number":"810619","date":"2017-09-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-02-21","scope":"MECHANICAL WORK, TO INCLUDE, INSTALLATION OF EXHAST DUCTWORK, AS PER PLANS."},{"number":"821642","date":"2017-10-05","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-11-16","scope":"INSTALL SOIL, VENT AND DOMESTIC WATER PIPE TO NEW PANTRY LOCATION. INSTALL ONE SINK AND WATER HEATER"},{"number":"819020","date":"2017-10-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-16","scope":"HVAC INSTALLATION INCLUDES RELOCATION OF VAV BOX, INSTALL DUCT AND AIR DEVICES FOR NEW OFFICE LAYOUT AS PER PLAN."},{"number":"825968","date":"2017-10-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-02-15","scope":"RELOCATE 41 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"823432","date":"2017-10-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-01-17","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"823344","date":"2017-10-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-17","scope":"INSTALL 11 FIRE ALARM DEVICES PER NFPA 72 INSTALL SECURITY DEVICE PER 2008(OFFICE SPACE)"},{"number":"817973","date":"2017-10-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-16","scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT.INSTALL 97 LIGHTS FIXTURES,26 LIGHT SWITCH,71 RECEPTACLES,3 FURNITURE FEED,6 EQUIPMENT FEED AND (1)208/120 VOLT PANEL PER 2008 NEC (OFFICE SPACE)"},{"number":"821670","date":"2017-10-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-02-21","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CREATE STORAGE SPACES FOR EXISTING BUSINESS AND PROFESSIONAL OFFICES ON THE 6TH FLOOR OF AN EXISTING HIGH RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"830334","date":"2017-11-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-02-12","scope":"RELOCATE 12 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"822281","date":"2017-11-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-09-04","scope":"FURNISH AND INSTALL 89 CAT6 PLENUM CABLE FOR VOICE AND DATA (OFFICE SPACE)"},{"number":"832250","date":"2017-12-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-30","scope":"HVAC INSTALLATION INCLUDING DUCTWORK,AS PER PLANS. (55) REGISTERS/DIFFUSERS."},{"number":"832644","date":"2017-12-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-04","scope":"INSTALL 12-RECEPTACLES,3-FURNITURE FEED,16-LIGHT FIXTURES AND 6-SWITCHES AS PER 2008 NEC (CC DISTRICT) INSTALL 2-SPEAKER STROBE FIRE ALARM DEVICES AS PER NFPA72"},{"number":"831866","date":"2017-12-14","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-04-30","scope":"INSTALL NEW PLUMBING SYSTEM FOR THREE COMPARTMENT SINK, HAND SINKS, FLOOR DRAINS AND FLOOR SINKS FOR KITCHEN AND BAR AT 3RD FLOOR CONFERENCE CENTER. THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUMBING CODE 2004"},{"number":"832501","date":"2017-12-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-14","scope":"RENOVATION TO EXISTING SPACE.INSTALL 10 LIGHT FIXTURES AND 7 LIGHT SWITCHES PER 2008 NEC (COMMERCIAL) INSTALL 2 FIRE ALARM DEVICES PER NFPA 72"},{"number":"827888","date":"2017-12-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-14","scope":"INSTALL 17 NEW AUDIO PANEL EXTEND EMERGENCY POWER TO NEW PANELS. INSTALL NEW CONDUITS AND AUDIO WIRE PER NFPA 72 (OFFICE SPACE)"},{"number":"841248","date":"2017-12-21","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-02-12","scope":"INTERIOR DEMOLITION OF NON-LOAD BEARING PARTITIONS AND FINISHES ONLY IN A PORTION OF THE 23RD FLOOR OF AN EXISTING HIGH RISE; NO STRUCTURAL WORK! SEPARATE PERMITS REQUIRED FOR ANY INTERIOR FITOUT, MECHANICAL, ELECTRICAL, PLUMBING OR FIRE SUPPRESSION WORK. **MODIFICATIONS TO ANY EXISTING FIRE-RESISTANCE RATED ASSEMBLIES PROHIBITED**"},{"number":"841773","date":"2018-01-04","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-08-06","scope":"RENOVATION/RECONFIGURATION OF EXISTING OFFICE SPACE."},{"number":"835584","date":"2018-01-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-16","scope":"FURNISH AND INSTALL NEW LIGHTING SWITCHES LIGHTING CONTROLS RECEPTACLES AND WIRING DEVICES ADD FIRE DEVICES"},{"number":"841350","date":"2018-01-11","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-01-11","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY"},{"number":"844593","date":"2018-01-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-23","scope":"RENOVATION TO EXISTING SPACE RELOCATE 6 LIGHT FIXTURES INSTALL 1 LIGHT SWITCH 4 RECEPTACLES AS PER 2008 NEC."},{"number":"849894","date":"2018-02-05","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-02-12","scope":"RELOCATE ONE SPRINKLER HEAD IN CONFERENCE ROOM."},{"number":"844862","date":"2018-02-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-02-12","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM FOR 23RD FLOOR OFFICE SPACE TO INCLUDE NEW DUCTWORK AND GRD'S AS PER APPROVED PLANS."},{"number":"853410","date":"2018-02-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-04-30","scope":"RELOCATE (64) SPRINKLER HEADS."},{"number":"855033","date":"2018-02-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-16","scope":"INSTALL 26 CAT6 PLENUM RATED LOW VOLTAGE NETWORK CABLES WITH THE LONGEST RUN 280' AS PER 2008 NEC (CC DISTRICT) NO BUILDING PERMIT ON FILE WITH THE DEPARTMENT"},{"number":"854030","date":"2018-03-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-12-11","scope":"NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. INTERIOR ALTERATIONS AND STRUCTURAL WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK."},{"number":"858129","date":"2018-03-09","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-10-01","scope":"INTERIOR DEMO OF NON LOAD BEARING PARTITIONS ONLY. (COMMERCIAL)"},{"number":"851710","date":"2018-03-29","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2018-05-04","scope":"AMENDMENT TO BUILDING PERMITS # 580591 AND # 580592, ISSUED ON APRIL 28, 2015 AND JULY 17, 2015, RESPECTIVELY; MODIFICATIONS INCLUDE ELIMINATION OF \"TILT\" AMUSEMENT ATTRACTION ELEMENT RESULTING IN CHANGES TO FLOOR PLANS (A SERIES SHEETS FROM GENSLER) AND NO STRUCTURAL WORK (AS SHOWN IN S-SERIES SHEETS FROM THORTON THOMASETTI AS PREVIOUSLY APPROVED UNDER PERMIT # 580592). SEPARATE ELECTRICAL AND FIRE SUPPRESSION PERMITS REQUIRED FOR ANY ASSOCIATED AMENDMENTS."},{"number":"863300","date":"2018-04-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-08-21","scope":"INTERIOR ALTERATION THROUGHOUT THE 29TH FLOOR OFFICE BUILDING AS PER SUBMITTED PLANS. NO CHANGE IN OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION."},{"number":"876177","date":"2018-05-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-12-11","scope":"RELOCATE 131 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"874684","date":"2018-05-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-21","scope":"INSTALLATION OF NEW HVAC SYSTEM FOR 29TH FLOOR OFFICE FIT-OUT TO INCLUDE DUCTWORK, FAN TERMINAL UNITS AND (126) REGISTERS/DIFFUSERS AS PER APPROVED PLANS."},{"number":"875128","date":"2018-05-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-12-11","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIAATED DUCTWORK IN A BUSINESS OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITONS VARY DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER."},{"number":"880848","date":"2018-05-29","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-07-13","scope":"INTERIOR DEMO OF NON-LOAD BEARING PARTITIONS ONLY. (COMMERCIAL)"},{"number":"878995","date":"2018-06-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-08-21","scope":"ALTERATIONS: INTERIOR PLUMBING; OFFICE BUILDING; 29TH FLOOR SUITE 2900 (COZEN O'CONNOR); 1 WATER CLOSET, 7 LAVATORY SINK, 1 COUNTER TOP SINK, 1 ELECTRIC WATER COOLER, 1 OPEN SITE DRAIN, 1 FLOOR DRAIN WITH TRAP PRIMER & 2 WATER HEATERS - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"885760","date":"2018-06-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-08-21","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- RELOCATING 179 SPRINKLER FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"885401","date":"2018-07-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-09-09","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY - OFFICE USE) ON THE 48TH THROUGH 50TH FLOORS OF AN EXISTING HIGHRISE. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"878194","date":"2018-07-10","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-08-26","scope":"FURNISH & INSTALL NEW LIGHTING & PROVIDE POWER FOR NEW OFFICE LAYOUT AS PER NEC 2008 CC DISTRICT"},{"number":"885691","date":"2018-07-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-14","scope":"FURNISH & INSTALL NEW SPEAKER STROBES, STROBES, SMOKE DETECTORS & NAC PANEL AS PER NFPA 72 CC DISTRICT"},{"number":"876145","date":"2018-07-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-14","scope":"INSTALL LIGHTING,LIGHTING CONTROLS,RECEPTS AND NEW PANELS ON 29TH FLOOR AS PER 2008 NEC (CC DISTRICT)"},{"number":"881102","date":"2018-07-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-12-11","scope":"ALTERATIONS: INTERIOR PLUMBING;ONE LIBERTY PLACE, 44TH & 45TH FLOOR-THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"879034","date":"2018-07-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 272 CAT6 PLENUM RATED CABLES ON 44TH & 45TH FLOORS, COAX CABLE TO 7 TV LOCATIONS, PROVIDE & INSTALL ALL TERMINATION HARDWARE AS PER 2008 NEC (CC DISTRICT)"},{"number":"884815","date":"2018-07-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL NEW STROBES SPEAKERS/STROBES AND SMOKES AS PER PLANS REMODELED OFFICE SPACE AS PER NFPA72 (CC DISTRICT)"},{"number":"893798","date":"2018-07-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-23","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT ON THE 48TH THROUGH 50TH FLOORS TO INCLUDE DUCTWORK AND MECHANICAL EQUIPMENT AS PER APPROVED PLANS."},{"number":"888359","date":"2018-07-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-02-14","scope":"FOR INSTALLING (2) SPRINKLERS WITH DOUBLE INTERLOCK PREACTION SYSTEM IN THE EVIDENCE ROOM TIED INTO EXISTING WET SYSTEM ON THE 29TH FLOOR, AS PER SUBMITTED PLANS AND CALCS."},{"number":"890938","date":"2018-08-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-16","scope":"RENOVATION EXISTING SPACE, INSTALL 132-CAT6 PLENUM CABLES LONGEST RUN 150' AND & 67-SOUND MASKING SPEAKERS WITH CONTROLS AS PER NEC 2008 CC DISTRICT"},{"number":"893431","date":"2018-08-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-01-08","scope":"INSTALL 15-TURNSTILES AND 15-CARD READERS IN THE LOBBY LEVEL AS PER 2008 NEC (CC DISTRICT)"},{"number":"893440","date":"2018-08-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-09-09","scope":"DISCONNECTION/DEMO, TEMP LTG & POWER, NEW/EXIST ELECTRICAL PANEL, BUSS SWITCHES, FEEDERS, LTG FIXTURES, SWITCHES, LTG CONTROLS, RECEPTS ETC AS PER NEC 2008 CC DISTRICT AND FIRE ALARM AS PER NFPA 72 **SEE LOG**"},{"number":"914345","date":"2018-10-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"24 CARD READERS SYSTEMS WITH LOW VOLTAGE ELECTRIC LOCKS ON 48TH,49TH AND 50TH FLOORS,USING PLENUM RATED CABLE CMP/FT6 WITH FIRE RELEASE PER 2008 NEC (OFFICE SPACE)"},{"number":"914640","date":"2018-10-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"FOR LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) ON THE 53RD FLOOR OF AN EXISTING OFFICE BUILDING TO INCLUDE DEMOLITION AND ERECTION OF PARTITION WALLS AND ALL ASSOCIATED FINISH WORK AS PER PLANS; BUILDING IS FULLY SPRINKLED, SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS."},{"number":"910408","date":"2018-10-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-09-09","scope":"INSTALLATION OF STRUCTURED COMMUNICATIONS CABLING SYSTEM, CATEGORY 6, 12 STRAND FIBER OPTIC BACKBONE, EQUIPMENT RACKS IN 3 IDF ROOMS, 301 TOTAL CAT6 CABLES PLENUM RATED LONGEST RUN 250 FEET AS PER 2008 NEC (CC DISTRICT)"},{"number":"916350","date":"2018-10-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"HVAC, INSTALLATION INCLUDING DUCTWORK AND VAV BOXES AS PER PLANS."},{"number":"928914","date":"2018-11-27","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-12-18","scope":"FOR MECHANICAL ALTERATIONS ON THE 24TH FLOOR OF AN EXISTING STRUCTURE, TO INCLUDE THE INSTALLATION OF A NEW HEAT PUMP WITH ASSOCIATED DUCTWORK, AS PER APPROVED PLANS."},{"number":"929759","date":"2018-11-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"INSTALL SINK, OPEN SITE DRAIN, ELECTRIC WATER HEATER- LABOR AND MATERIAL TO EXTEND FROM EEXISTING SANITARY AND DOMESTIC WATER"},{"number":"926488","date":"2018-11-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-11","scope":"INSTALL LIGHTING FIXTURES, RECEPTACLES, AND POWER PER PLANS AND SPECS AND IN ACCORDANCE WITH NEC 2008."},{"number":"933348","date":"2018-12-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. RELOCATE FOURTEEN (14) SPRINKLER HEADS"},{"number":"934892","date":"2019-01-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-11","scope":"INSTALL (10) NEW SPEARKER/STROBE AND (1) DUAL SYNC MODULE FOR AUX POWER SUPPLY.AS PER NFPA 72 (CC DIST)"},{"number":"938369","date":"2019-01-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-07-15","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 30TH FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE BUILDING TO FIT-OUT FOR NEW TENANT AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"939048","date":"2019-01-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-11","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE TENANT LAYOUT ON THE 30TH FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS."},{"number":"947935","date":"2019-02-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-07-15","scope":"2 PLUMBING FIXTURES WITH PIPING, 1-WATER HEATER"},{"number":"950885","date":"2019-02-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2020-03-09","scope":"RELOCATE 264 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"949487","date":"2019-03-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-15","scope":"DISCONNECTS, TEMP LIGHTING & POWER, INSTALL NEW LIGHT FIXTURES AND CONTROLS. REWORK AND REUSE EXISTING PANELS. PROVIDE NEW RECEPTACLES, FLOOR OUTLETS, AND FURNITURE FEEDS. INSTALL NEW FIRE ALARM DEVICES, CONNECTING TO EXISTING SYSTEMS. PROVIDE EMPTY BOX AND STUB-UP FOR TELE/DATA/SECURITY. PROVIDE POWER TO HVAC AS PER 2008 NEC AND NFPA 13. (CC DIST)"},{"number":"888978","date":"2019-03-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-09-24","scope":"FOR THE INSTALLATION OF TWO (2) FM-200 CLEAN AGENT SUPPRESSION SYSTEMS FOR SERVER ROOMS 1 & 2, IN ACCORDANCE WITH NFPA 2001, AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK."},{"number":"960346","date":"2019-03-25","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2019-05-31","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. . STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS"},{"number":"953025","date":"2019-03-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-06-19","scope":"PROVIDE AND INSTALL 226 COMMSCOPE CAT 6 PLENUM RATED 4 PAIR CABLES. PROVIDEAND INSTALL 2 COMMSCOPE RG6 QUAD SHEILD PLENUM RATED COAX. LONGEST CABLE RUN IS 200 FEET AS PER 2008 NEC. (CC DIST)"},{"number":"961210","date":"2019-04-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 15TH FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE BUILDING TO FIT-OUT FOR NEW TENANT AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"894725","date":"2019-04-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-08-23","scope":"INSTALL NEW SANITARY,WASTE & VENT & HOT & COLD WATER PIPING FOR NEW 48TH 2-SINKS, 49TH-1-SINK, 1-WATER CLOSET, 2-LAVS, 1-SHOWER & 1-FLOOR DRAIN, & 50TH FLOOR 2-SINKS,1-LAV, 1-FLOOR DRAIN AT PANTRY THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"970454","date":"2019-04-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"FURNISH AND INSTALL 110 CAT 6 PLENUM PLATED CABLES, PER 2017 NEC"},{"number":"969812","date":"2019-05-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"FURNISH LABOR TO RELOCATE 6 VAV BOXES. FURNISH AND INSTALL ONE HEAT PUMP AND ONE VAV BOX. DUCT & AIR DEVICES FOR NEW OFFICE LAYOUT."},{"number":"973033","date":"2019-05-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-07-15","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)-RELOCATE 75 SPRINKLER HEADS ON THE 30TH FLOOR. FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"960776","date":"2019-05-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-02-10","scope":"LEVEL 2 ALTERATION FOR RENOVATION TO OFFICE TENANT SPACE WITHIN EXIST. MIXED-USE HIGH-RISE OFFICE BUILDING PER APPROVED PLANS INCLUDING DEMOLITION OF EXIST. PARTITIONS, NEW PARTITIONS FOR OFFICE & CONFERENCE RM SPACES, EXIST. STAIRWAY GUARD & RAIL INSTALL, & ALL ASSOCIATED FINISH WORK; BUILDING IS FULLY SPRINKLERED. SEPARATE PERMIT REQ'D FOR ANY MECH., ELEC., PLUMB., & FIRESUPP WORK. (2018 IEBC)"},{"number":"977660","date":"2019-05-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"RELOCATE 40 EXISTING SPRINKLER HEADS"},{"number":"974781","date":"2019-05-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"RENOVATION TO EXISTING SPACE INSTALL 142 LIGHTS 94 SWITCH 113 RECEPS 10 FLOOR RECEPS 11 EQUIPMENT POWER 1-208/120V PANEL 50' BASKET TRAY PER 2008 NEC"},{"number":"981196","date":"2019-05-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"FURNISH AND INSTALL SANITARY VENT AND DOMESTIC WATER PIPING TO NEW PANTRY LOCATION, FURNISH AND INSTALL 1 PANTRY SINK, 1 WATER HEATER, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004"},{"number":"984517","date":"2019-06-11","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2019-08-09","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. . STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS."},{"number":"980908","date":"2019-06-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-12-30","scope":"FURNISH AND INSTALL NEW POWER AND LIGHTING IN EXISTING OFFICE SPACE PER PLANS AND SPECS AS PER 2017 NEC (CC DIST)"},{"number":"976855","date":"2019-06-17","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2020-01-07","scope":"AMEND ALTERATION PERMIT NO. 885401 TO CHANGE 48TH FLOOR LAYOUT IN AN EXISTING STRUCTURE AS PER APPROVED PLANS. NO CHANGE IN OCCUPANCY CLASSIFICATION. SEE AP#885401 FOR ALL SUPPORTING DOCUMENTATION. 49TH AND 50TH FLOORS TO REMAIN AS PREVIOUSLY APPROVED. ***SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**"},{"number":"984128","date":"2019-06-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-12-23","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT ON THE 30TH FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS."},{"number":"986478","date":"2019-06-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-10","scope":"INSTALL COMPUTER LINES (10-15), LOW VOLTAGE ON 42ND & 43RD FLOOR, PER 2017 NEC"},{"number":"984509","date":"2019-06-19","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-12-23","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 30TH FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE BUILDING TO FIT-OUT FOR NEW TENANT AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"978639","date":"2019-06-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-23","scope":"INSTALLATION OF A NEW MECHANICAL SYSTEM TO ACCOMMODATE THE EXISTING 42ND AND 43RD FLOORS ( MORGAN &STANLEY) OF AN EXISTING HIGH-RISE BUILDING TO INCLUDE , NEW AIR HANDLERS, DIFFUSERS, EXHAUST FAN AND ALL ASSOCIATED DUCTWORK AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL OR FIRE SUPPRESSION WORK**"},{"number":"987965","date":"2019-06-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2020-01-23","scope":"RELOCATE 56 HEADS ON 42 FLOOR AND 16 HEADS ON 43RD FLOOR. (CMX-5)"},{"number":"989696","date":"2019-06-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"FURNISH AND INSTALL 55 CAT5E PLENUM RATED CABLES TO VARIOUS LOCATION AVERAGE LENGTH 150 PER CABLE AS PER 2017 NEC"},{"number":"990337","date":"2019-07-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-08-09","scope":"FURNISH SANITARY, SANITARY VENT & DOMESTIC WATER PIPING & FURNISH & INSTALL 1-PANTRY SINK, & 1-INDIRECT WASTE & WATER HEATER THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"980833","date":"2019-07-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"RENOVATION TO EXISTING SPACE. INSTALL 11 SPEAKER/STROBE, 5 STROBE, 1 RELAY, 1 POWER SUPPLY AS PER DRAWINGS AS PER NFPA 72 (CC DIST)"},{"number":"990590","date":"2019-07-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2022-06-07","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 48TH FLOOR CORRIDORS AND RESTROOMS IN AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"988504","date":"2019-07-09","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-09-23","scope":"TENANT FITOUT PROJECT AS PER THE 2017 NEC AND ENGINEERED DRAWINGS BY D2 GROUPS LLC. 59-LIGHTING FIXTURES. 22-SWITCHES. 42-RECEPTACLES. 01-WIRE AND CONNECT TO EXISTING PANELS. **NO FIRE ALARM ON THIS PERMIT**"},{"number":"984704","date":"2019-07-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-12-23","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.RELOCATE 30 SPRINKLER HEADS TO ACCOMMODATE NEW LAYOUT."},{"number":"984513","date":"2019-07-15","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2019-08-30","scope":"EXPANDED AREA OF CONSTRUCTION ON THE 48TH FLOOR ONLY. AMEND PERMIT #893440. INSTALL ADDITIONAL LTG FIXTURES & DEVICES , LTG CONTROL SWITCHES & RECEPTACLES. ADDITIONAL FA DEVICES TO SYSTEM, EMPTY BOX & STRING FOR TELE/DATA. ADDITIONA DEMO & MISC DISCONNECTIONS. REWORK EXISITNG PANELS.PROVIDE NEW (3) PANELS.**MIDDLE ATLANTIC INSPECTION AGENCY**"},{"number":"994231","date":"2019-07-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-09-23","scope":"4-RELOCATE EXISTING SPEAKER/STROBE DEVICES, 2-INSTALL SMOKE DETECTORS & 1-TEST & RECERTIFICATION AS PER NFPA 72 CC DISTRICT"},{"number":"988835","date":"2019-08-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-12-30","scope":"INSTALL (6) NEW NOTIFICATIONS DEVICES IN EXISTING OFFICE TO MATCH NEW LAYOUT PER PLANS AND SPECS AND NFPA 72."},{"number":"996084","date":"2019-08-05","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-12-07","scope":"INSTALLTION OF THREE NEW FIXTURES IN ACCORDANCE WITH 2004 IPC."},{"number":"995076","date":"2019-08-07","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-06-22","scope":"FURNISH AND INSTALL NEW BRANCH POWER AND LIGHTING IN EXISTING CORRIDOR PER PLANS AND SPEC AND IN ACCORDANCE WITH NEC 2017.(CC DIST)"},{"number":"989312","date":"2019-08-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2020-01-23","scope":"ALTERATION FOR RENOVATION TO OFFICE TENANT SPACE WITHIN EXIST. MIXED-USE HIGH-RISE OFFICE BUILDING 6 SINKS AND 6 UNDER COUNTER ELECTRIC INSTANTANEOUS WATER HEATER."},{"number":"1002523","date":"2019-08-19","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2020-03-09","scope":"RELOCATING (20) SPRINKLER HEADS TO ACCOMMODATE FOR RENOVATIONS ON 48TH FLOOR."},{"number":"1001482","date":"2019-09-13","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-10-24","scope":"FURNISH AND INSTALL 7 NOTIFICATION DEVICES AND 2 SMOKE DETECTORS IN AN EXISTING CORRIDOR PER NFPA 72"},{"number":"996085","date":"2019-10-08","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2021-11-05","scope":"FOR THE INSTALLATION OF REGISTERS/DIFFUSERS AND DUCTWORK AS PER APPROVED PLAN. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL AND PLUMBING WORK."},{"number":"1019210","date":"2019-10-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-02-03","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 7TH FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"1021375","date":"2019-10-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-11-21","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"1022572","date":"2019-10-28","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2021-09-13","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 43RD FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE BUILDING (ONE LIBERTY PLACE) AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"1025549","date":"2019-11-07","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2020-01-14","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; INCLUDING UNDERPINNING, EXCAVATION, AND REMOVAL OF FOUNDATION SLAB. NO WORK MAY BE PEFORMED IN THE BASEMENT OR CELLAR)"},{"number":"1025775","date":"2019-11-07","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2020-01-10","scope":"FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"1026439","date":"2019-11-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2020-02-20","scope":"RELOCATE 4 EXISTING SPRINKLER HEADS ON THE 47TH FLOOR TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 ANA ALL LOCAL CODES."},{"number":"1025086","date":"2019-11-12","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2021-07-12","scope":"43RD FL CITI BANK FURNISH & INSTALL NEW KIT SINK WITH 6 GAL ELEC HW TANK TO EXT'G STACK AS PER 2004 PHILA PLUM CODE. SEPERATE ELEC PERMIT REQ'D"},{"number":"1025081","date":"2019-11-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2020-02-03","scope":"6TH FL AARP REMOVE AND REPLACE EXT'G 6 GAL ELEC DOM HOT WATER (LIKE AND SAME) AS PER 2004 PHILA PLUM CODE"},{"number":"1024366","date":"2019-11-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-20","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"1023966","date":"2019-11-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-02-20","scope":"FOR LEVEL II ALTERATIONS TO THE 47TH FLOOR LEVEL OF AN EXISTING BUILDING FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"1027245","date":"2019-11-20","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-03","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT ON THE 6TH FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS."},{"number":"1029386","date":"2019-11-21","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2020-02-03","scope":"AMEND ALTERATIONS PERMIT NO. 1019210 TO CORRECT PERMIT LANGUAGE TO LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO *6TH* FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS."},{"number":"1029484","date":"2019-11-25","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-02-11","scope":"INSTALL 22-CAT6 LOW VOLTAGE CABLES FOR COMPUTER LOCATIONS AS PER 2017 NEC (CC DISTRICT)"},{"number":"1029409","date":"2019-11-26","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-06-18","scope":"FOR LEVEL II ALTERATIONS TO THE 43RD FLOOR LEVEL OF AN EXISTING BUILDING FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MEPS WORK."},{"number":"1025443","date":"2019-12-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-04","scope":"INSTALL LIGHT FIXTURES, NEW WALL SWITCHES/OCCUPANCY SENSORS, NEW RECEPTACLES/WIRING, POWER CONNECTIONS TO MISC EQUIPMENT AS PER ELECTRICAL DRAWINGS **BUILDING PERMIT# 1019210**"},{"number":"1033636","date":"2019-12-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2020-02-03","scope":"RELOCATING (9) SPRINKLER HEADS TO ACCOMDATE RENOVATIONS. (CMX-5)"},{"number":"1032860","date":"2019-12-11","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-06-09","scope":"INSTALL 61 CAT6 LOW VOLTAGE COMPUTER LOCATIONS AS PER 2017 NEC"},{"number":"1032890","date":"2019-12-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-20","scope":"ALTERATION TO EXISTING OFFICE SPACE, REMOVE LIGHTS AND INSTALL NEW 1X4 AND DOWNLIGHTS. INSTALL NEW RECEPTACLES AND FURNITURE FEEDS. INSTALL ONE NEW FIRE ALARM DEVICE PER NFPA 72 AND 2017 NEC (CC DIST)"},{"number":"1036583","date":"2019-12-19","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-06-18","scope":"relocate 32 existing Sprinkler heads on the 43rd floor to accommodate Tenant Layouts as per NFPA No. 13 and all Local Codes"},{"number":"1034953","date":"2019-12-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-03","scope":"INSTALL (QTY) FIRE ALARM STROBE DEVICES AS IN ACCORDANCE WITH NFPA72.(CC DISTRICT)"},{"number":"1036299","date":"2019-12-30","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-12-09","scope":"FOR LEVEL II ALTERATIONS TO THE 36TH FLOOR LEVEL OF AN EXISTING BUILDING FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"1039896","date":"2020-01-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-04-14","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 3RD FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"1039578","date":"2020-01-21","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-06-15","scope":"NEW LIGHT FIXTURES CONTROLLED VIA LOCAL CONTROLS. NEW RECEPTACLES FED FROM EXISTING PANEL BOARDS. TELE/DATA, SECURITY AND CCTV BACK BOXES AND RACEWAY ONLY. (WIRING AND DEVICES BY OTHERS) FINAL POWER CONNECTIONS TO MODULAR FURNITURE AND HVAC EQUIPMENT"},{"number":"1045877-RI","date":"2020-02-06","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-06-08","scope":"EXTEND EXISTING CIRCUITS AND ADD DEVICES PER THE RED HAWN DRAWINGS SUBMITTED WITH THIS PERMIT APPLICATION PER NFPA 72 (CC DIST)"},{"number":"1044457","date":"2020-02-06","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-05-07","scope":"Replacement of fixture only: 1 kitchen sink per 2004 PPC."},{"number":"1049866","date":"2020-02-14","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2022-03-22","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. FOR RELOCATION OF FOUR(4) DIFFUSERS TO CONJUNCTION WITH AP#1039896."},{"number":"1048620","date":"2020-02-24","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2020-06-18","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND, APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"1044458","date":"2020-02-26","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-06-18","scope":"Install supply and DWN pipe to 2 kitchen sinks, 1 open site drain and 1-10 gallon electric water heater per 2004 PPC"},{"number":"1048180","date":"2020-02-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-06-18","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 43RD FLOOR CORRIDOR AREA IN AN EXISTING HIGH-RISE BUILDING (ONE LIBERTY PLACE) AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"1048623","date":"2020-02-28","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2021-09-22","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"1047127","date":"2020-03-10","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-08-18","scope":"PROVIDE AND INSTALL 53 CAT6 PLENUM RATED 4 PAIR CABLES AND 1 COMMSCOPE RG6 QUAD SHIELD PLENUM RATE COAX. LONGEST CABLE RUN IS 200 FEET PER 2017 NEC (CC DIST)"},{"number":"1056417","date":"2020-03-10","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-06-15","scope":"REPLACEMENT OF EQUIPMENT IN KIND WITH NO ADDITIONAL WIRING TO REPLACE EXISTING LAMPS WITH DED AND REMOVE & REPLACE WALL & CEILING DEVICES IN KIND AS PER NEC 2017 CC DISTRICT"},{"number":"1057511","date":"2020-03-12","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-04","scope":"RELOCATE FOUR EXISTING LAY IN TYPE FIXTURES TWO NEW RECESSED DOWN LIGHTS ONE NEW SWITCH THREE DUPLEX RECEPTACLES ONE POKE THRU DEVICE ALL CONNECTED TO EXISTING WIRING AS PER 2017 NEC"},{"number":"CP-2020-000893","date":"2020-05-07","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-11-10","scope":"FOR INTERIOR ALTERATIONS ON THE 31ST FLOOR OF AN EXISTING HIGH RISE OFFICE BUILDING, TO INCLUDE NEW INTERIOR PARTITIONS AND INTERIOR FINISHES, AS PER APPROVE PLANS."},{"number":"1045877","date":"2020-06-09","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-07-21","scope":"EXTEND EXISTING CIRCUITS AND ADD DEVICES PER THE RED HAWN DRAWINGS SUBMITTED WITH THIS PERMIT APPLICATION PER NFPA 72 (CC DIST)"},{"number":"FP-2020-000104","date":"2020-06-16","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-12-09","scope":"Relocate 32 Heads in suite 3600"},{"number":"MP-2020-001781","date":"2020-07-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2020-11-10","scope":"FOR THE INSTALLATION OF A NEW HVAC SYSTEM EXTENSION FROM EXISTING MAIN BUILDING DUCT WITH ASSOCIATED DUCTWORK, (13) VAV BOXES, (2) EXHAUST FANS AND (68) DIFFUSERS/GRILLES/REGISTERS. AS PER APPROVED PLANS OF THE 5TH FLOOR OF THE WOOD BUILDING. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION."},{"number":"EP-2020-003767","date":"2020-07-14","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-08-13","scope":"Rough-In Permit for EP-2020-003765 installation of new light fixtures, receptacles, new electrical panels"},{"number":"PP-2020-004336","date":"2020-07-23","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-11-10","scope":"For Interior Plumbing to include [1]KITCHEN SINK, [1]INDIRECT WASTE/HUB DRAIN, and [1] WATER HEATER as per 2018 Philadelphia Plumbing Code."},{"number":"EP-2020-001847","date":"2020-07-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"Johnson Controls to furnish and install a video Intercom station at the front entrance, rear entrance, wall near IT room, near the rear cubicals, and near the IT room. An Aiphone power supply shall be plugged into a 120V receptacle in the IT room."},{"number":"CP-2020-003366","date":"2020-07-30","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-04-14","scope":"For prescriptive alterations to the Group B office tenants on the 7th, 8th, and 54th floors of an existing high-rise office building, to erect partitions for new meeting rooms (<50 occ., ea.) and offices, as per plans; separate permits required for all MEP/FSP work; sprinklers installed throughout; no work outside of tenant space demising walls."},{"number":"FP-2020-001082","date":"2020-07-30","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-11-10","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Relocate 59 heads ON 31st fl."},{"number":"EP-2020-005658","date":"2020-08-05","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-10-29","scope":"Data Cabling: furnish and install (1) fiber optic cable, (37) CAT-6A cables"},{"number":"EP-2020-003765","date":"2020-08-13","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-09-24","scope":"installation of new light fixtures, receptacles, (4) new electrical panels, bus duct switch,45 kva transformer, wiring hvac equipment as per the 2017 nec. NO FIRE ALARM WORK."},{"number":"EP-2020-003790","date":"2020-09-14","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2023-12-05","scope":"MacDonald Electric will furnish and install new branch circuits as shown on the drawings. We will run new branch circuits in EMT conduit too feed new HVAC units as per 2017 NEC. MacDonald Electric will relocate F/A as required for this project as shown on the drawings. MacDonald Electric will furnish and install (2) new duct detectors for Fire Alarm as per 2016 NFPA 72."},{"number":"EP-2020-004334","date":"2020-09-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-11-09","scope":"Fire alarm Installation. 13 speaker strobes and power supply as per 2016 NFPA72."},{"number":"EP-2020-007581","date":"2020-09-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-03","scope":"Furnish & Install (40) Cat 6 plenum cables for voice/data as per 2017 nec"},{"number":"EP-2020-007776","date":"2020-09-24","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-10-08","scope":"Rough-In Permit for EP-2020-007770 Install new light fixtures, receptacles tele/data raceways and HVAC power wiring utilizing existing service panels as per drawings as per 2017 nec"},{"number":"PP-2020-009268","date":"2020-09-25","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-12-09","scope":"Furnish and install sanitary, sanitary vent and domestic water piping with insulation to new fixtures. Furnish and install 1 kitchen sink and 1 electric hot water heater."},{"number":"MP-2020-003447","date":"2020-09-28","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2020-12-09","scope":"FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE ONE VAV BOX, AIR DEVISES, DIFFUSERS/REGISTERS/GRILLES, AND ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"MP-2020-001789","date":"2020-09-29","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-04-16","scope":"FOR MECHANICAL ALTERATIONS ON PARTIAL FOURTH FLOOR OF AN EXISTING OFFICE BUILDING, TO INCLUDE NEW SPLIT SYSTEMS, HEAT PUMPS WITH REGISTERS/DIFFUSERS AND ASSOCIATED DUCTWORK, AS PER APPROVED PLANS."},{"number":"EP-2020-007770","date":"2020-10-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-01","scope":"Install new light fixtures, receptacles, tele/data raceways, and HVAC power wiring utilizing existing service panels as per drawings as per 2017 NEC. Install fire alarm system as per 2016 NFPA 72."},{"number":"FP-2020-001976","date":"2020-10-26","work":"Rough-In","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-11-05","scope":"Rough-In Permit for FP-2020-001945 (AIG, 37th floor)"},{"number":"FP-2020-001945","date":"2020-11-05","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2023-01-09","scope":"FOR THE REMOVAL OF EXISTING PRE-ACTION SYSTEM AND CONVERSION TO WET SYSTEM, SYSTEM TO BE TIED INTO EXISTING WET SYSTEM AS PER NFPA 13. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS."},{"number":"EP-2020-002992","date":"2020-11-30","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-12-03","scope":"Installing lights, receptacles, switches as per 2017 NEC. Install fire alarm devices as per 2016 NFPA 72."},{"number":"FP-2020-002478","date":"2020-12-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-04-14","scope":"Relocate (11) sprinkler heads on the 7th & 8th floor. See CP-3366"},{"number":"EP-2020-011346","date":"2020-12-14","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-27","scope":"Extend existing circuits and add as required. Replace light fixtures with energy efficient LED as per 2017 NEC. No Fire Alarm work."},{"number":"EP-2021-000272","date":"2021-01-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-27","scope":"Replacement of existing light fixtures illuminating the buildings Spire. Replace total of (72). No new wiring, No fire alarm as per 2017 nec"},{"number":"GP-2021-003559","date":"2021-04-22","work":"Shelter/Platform","type":"General","description":"General Permit","status":"Completed","completedDate":"2021-11-10","scope":"SHELTER PLATFORM PERMIT- Erection of sidewalk shelter platform 200 l.f. on Market St. with the deck at 300 P.S.I. each as per Engineered Plans. Streets Department permit is required for sidewalk closure prior to the start work."},{"number":"CP-2021-003778","date":"2021-07-12","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-10-28","scope":"INTERIOR ALTREATION TO CREATE 2 WELLNESS ROOM FROM AN EXISTING COPY ROOM ON 11TH FLOOR OF AN EXISTING STRUCTURE AS PER APPROVED PLAN."},{"number":"PP-2021-014136","date":"2021-08-04","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-10-26","scope":"Remove and replace existing plumbing fixtures with new, 1 pantry sink and 1 electric water heater."},{"number":"EP-2021-007585","date":"2021-08-04","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-10-28","scope":"Re-wire (2) light fixture, install (2) switch, (2) receptacle as per 2017 NEC"},{"number":"CP-2021-005152","date":"2021-08-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-11-26","scope":"FOR A LEVEL II INTERIOR ALTERATION TO AN EXISTING BUSINESS OCCUPANCY LOCATED ON THE 30TH FLOOR OF AN BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF NEW WALL PARTITIONS AND TO PROVIDE FINISHES AND FURNISHINGS THROUGHOUT THE DESIGNATED AREA . ALL WORK TO BE DONE PER APPROVED PLANS.**BUILDING TO IS FULLY SPRINKLERED **IEBC 2018** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**ANY DEVIATION TO THE APPROVED SCOPE OF WORK WILL REQUIRED AN AMENDED PERMIT**"},{"number":"FP-2021-002383","date":"2021-08-25","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-11-22","scope":"Relocate 33 heads See CP-2021 005152"},{"number":"MP-2021-005533","date":"2021-09-01","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-11-26","scope":"FOR ALTERATIONS TO AN EXISTING HVAC MECHANICAL SYSTEM TO INCLUDE REGISTERS/DIFFUSERS/GRILLES AND ASSOCIATED DUCTWORK."},{"number":"EP-2021-009425","date":"2021-09-16","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-09-22","scope":"Fire Alarm: Install (2) strobes as per NFPA 72"},{"number":"CP-2021-005656","date":"2021-09-21","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-07-14","scope":"Renovation of existing restrooms on the third floor as per approved plans."},{"number":"PP-2021-017088","date":"2021-09-21","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-06-23","scope":"Swapping out 6 Lavs 1 Urinal utilizing existing rough in NO PIPING"},{"number":"PP-2021-017092","date":"2021-09-21","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-06-23","scope":"Swap out 6 Lavs 1 Urinal utilizing existing rough in NO PIPING"},{"number":"CP-2021-005655","date":"2021-09-21","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-07-14","scope":"FOR RENOVATIONS (LEVEL I ALTERATION) TO EXISTING 31ST FLOOR RESTROOM AS PER APPROVED PLANS."},{"number":"FP-2021-002558","date":"2021-09-22","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-07-14","scope":"PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of 6 Sprinkler Heads in Bathroom on 3rd Floor as per attached standards. Deviations from these standards require submission of construction and site plans. (CP-2021-005656)"},{"number":"FP-2021-002574","date":"2021-09-22","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-07-14","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (6) Sprinkler Heads in 31st Floor Bathroom (CP-2021-005655)"},{"number":"EP-2021-010361","date":"2021-09-24","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-11-10","scope":"Relocate (26) light fixture, Install (22) light fixture (14) switch, (44) receptacle as per APPROVED DRAWINGS-2017 NEC."},{"number":"EP-2021-010610","date":"2021-09-30","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-11-10","scope":"Fire Alarm: Install (5) strobe, (3) speaker/strobe AS PER APPROVED DRAWINGS . 2016 NFPA-72,2018 Phila Fire Code."},{"number":"EP-2021-011835","date":"2021-10-19","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-11-22","scope":"Furnish & Install (55) Cat 6 Plenum cables for voice/data & (3) access control cables / Longest Run 200' as per 2017 nec"},{"number":"ZP-2021-012529","date":"2021-10-22","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Residential - Household Living - Multi-Family"},{"number":"CP-2021-005842","date":"2021-11-01","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-04-04","scope":"For prescriptive compliance method alterations (w/o a change in occupancy) to erect new Group S-2 bicycle storage room within the basement of an existing high-rise office building, as per plans; separate permits required for any MEP/FSP work; building is fully sprinklered; no other work on this permit; tamper-proof locks for individual bicycles to be provided as per Section 14-804(3)(b) in the Zoning Code; see ZP-2021-012529 for use permit documenting bicycle parking."},{"number":"FP-2021-003149","date":"2021-11-03","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-04-01","scope":"Relocating (6) Existing Sprinkler Heads See CP-2021-005842"},{"number":"MP-2021-007199","date":"2021-11-22","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-04-01","scope":"FOR NEW HVAC SYSTEM TO THE BIKE STORAGE ROOM AS PER APPROVED PLANS."},{"number":"EP-2021-013324","date":"2021-11-24","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-03-25","scope":"ELECTRICAL: Install wiring for light fixtures, devices, and mechanical equipment per NEC 2017. FIRE ALARM: Install wiring and notification appliance per 2016 NFPA 72. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS."},{"number":"EP-2022-000913","date":"2022-01-31","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-07-07","scope":"Replace existing fixtures with new LED energy-efficient fixtures in the men/ women's room on the 31st floor. Total: 4 downlights, 5 linear soffit lights. The fire alarm is exiting to remain. No fire alarm work. As per 2017 NEC"},{"number":"EP-2022-000912","date":"2022-01-31","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-07-07","scope":"Replace existing fixtures with new LED energy-efficient fixtures in the men/ women's room on the 3rd floor. Total: 4 downlights, 5 linear soffit lights. The fire alarm is exiting to remain. No fire alarm work. As per 2017 NEC"},{"number":"CP-2022-003030","date":"2022-05-31","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-01-06","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. WORK TO BE LIMITED TO THE 15TH & 16TH FLOOR LEVEL FLOOR OF THE STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING TO IS FULLY SPRINKLERED. LIMITED STRUCTURAL WORK TO BE INCLUDED IN THE SCOPE OF WORK. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2022-003913","date":"2022-07-14","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-09-26","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 51ST AND 52ND FLOOR OFFICE SPACES WITHIN AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"GM-2022-006757","date":"2022-08-03","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2023-02-21","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2022-004079","date":"2022-08-04","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-11-08","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 48TH FLOOR LEVEL FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING TO IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2022-008089","date":"2022-08-22","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-10-26","scope":"Furnish and install 68 duplex receptacles, 6 GFI's, 7 wall furniture feeds, 4 floor boxes, 1 L5-30R device and 2 L6-30R devices, 2 water heaters, 1 crac feed, 160 light fixtures, 12 exits, lighting controls as per 2017 NEC. Furnish and install fire alarm as per drawings as per 2016 NFPA 72."},{"number":"EP-2022-008427","date":"2022-08-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-12-20","scope":"Install 3 downlights, 2 exit signs and 1 wall occupancy sensor utilizing existing circuits. Recircuit existing to remain devices as per 2017 NEC"},{"number":"FP-2022-002435","date":"2022-09-08","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-09-25","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating 46 sprinkler heads for renovations"},{"number":"PP-2022-012601","date":"2022-09-09","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-10-26","scope":"Demo existing sinks and water heater, replace and install 2 new sinks and 2 instantaneous water heaters."},{"number":"EP-2022-009118","date":"2022-09-09","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-10-26","scope":"Provide and install 40 Cat6 plenum cables at 150' average. Provide and install 4 RG6 plenum cables at 150' average. Provide and install 4 Cat6A plenum cables at 150' average. All cabling will be installed per NEC 2017. No rescue systems work."},{"number":"FP-2022-002450","date":"2022-09-12","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-10-26","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. (CP-2022-004079) Relocate (77) Sprinkler Heads on the 48th Floor"},{"number":"MP-2022-004502","date":"2022-09-14","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-10-26","scope":"FOR ALTERATION TO THE EXISTING HVAC SYSTEM TO ACCOMMODATE NEW FLOOR LAYOUT AS PER APPROVED PLANS."},{"number":"GP-2022-008148","date":"2022-09-23","work":"Shelter/Platform","type":"General","description":"General Permit","status":"Completed","completedDate":"2023-04-17","scope":"SHELTER PLATFORM PERMIT- Erection of sidewalk shelter platform 180 l.f. on Market St. and 160 l.f. on S. 17th St. with the deck at 300 P.S.I. each as per Engineered Plans. Streets Department permit is required for sidewalk closure prior to the start work."},{"number":"CP-2022-005572","date":"2022-10-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-09-25","scope":"FOR THE LEVEL I INTERIOR ALTERATIONS TO AN EXISTING RESTROOM LOCATED ON THE 46TH FLOOR OF AN EXISTING STRUCTURE. ALTERATIONS LIMITED TO FINISHES UPGRADE, FURNISHING, AND ACCESSIBILITY IMPROVEMENTS . BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2022-010826","date":"2022-10-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-04-12","scope":"Remove eight light fixtures and install eight new light fixtures in existing location of restrooms AS PER NEC 2017"},{"number":"PP-2022-015078","date":"2022-10-27","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-08-21","scope":"Replace 14 plumbing fixtures"},{"number":"MP-2022-005392","date":"2022-11-02","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-09-25","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"EP-2022-011161","date":"2022-11-04","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-07-21","scope":"Install new light fixtures and lighting controls, receptacles, tele/data raceways utilizing existing circuits as per drawings as per 2017 NEC. Install fire alarm . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS -2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"EP-2022-011267","date":"2022-11-28","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-09-19","scope":"STATEMENT OF WORK: 51ST FLOOR: Cabling will be CommScope Category 6 plenum rated 4-pair. • Provide labor to demo existing cabling in Phase 1 and Phase 2. • Provide and install six (6) furniture mount dual locations in Phase 1. • Provide and install four (4) flush mount dual locations in Phase 1. • Provide and install five (5) flush mount dual locations in Phase 2. • Provide and install one (1) HDMI plenum rated 50’ cable. • Provide and install CommScope faceplates and modular jacks as required for termination of the 4-pair cables at the workstation location. • Provide and install one (1) CommScope Category 6 48-port patch panel. This will be installed at the closet location for termination of the 4-pair cables. • Provide and install all necessary j-hooks as required to facilitate cable distribution. • Provide labor and materials to seal all through penetrations of fire rated walls for telecommunications use to maintain necessary fire ratings. • Bluestone Communications, Inc. will provide labor to test and label all new cabling installed by Bluestone Communications, Inc. throughout the facility. Test results will be submitted as part of the asbuilt package. 52ND FLOOR: Cabling will be CommScope Category 6 plenum rated 4-pair. • Provide labor to demo existing cabling in Phase 1 and Phase 2. • Provide and install six (6) furniture mount dual locations in Phase 1. • Provide and install four (4) furniture mount dual locations in Phase 2. • Provide and install four (4) flush mount dual locations in Phase 1. • Provide and install seven (7) flush mount dual locations in Phase 2. • Provide and install one (1) floor mount dual location in Phase 2. • Provide and install two (2) HDMI plenum rated 50’ cables. Bluestone Communications, Inc. Bid Number # 22-08700 September 21, 2022 Page 2 STATEMENT OF WORK (Continued): 52ND FLOOR (Continued): • Provide and install CommScope faceplates and modular jacks as required for"},{"number":"GM-2022-010608","date":"2022-12-06","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2024-01-04","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2023-000249","date":"2023-01-19","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-09-25","scope":"For Level II Alterations within an existing Group B occupancy on the partial 48th floor in an existing high-rise structure, as per plans; separate permits required for all MEP/FSP work; no structural work on this permit; building is currently sprinklered throughout in accordance with NFPA 13, with standpipes installed within the exit stairways in accordance with NFPA 14, and with a fire alarm system installed throughout in accordance with NFPA 72; if field conditions vary contact design engineer prior to the start of any work; compliance with Philadelphia Fire and Property Maintenance Codes required prior to occupancy."},{"number":"CP-2023-000100","date":"2023-01-23","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-08-04","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING HIGH RISE BUILDING ON THE 32ND AND 33RD FLOOR FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2023-000282","date":"2023-02-06","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-08-04","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (295) sprinkler heads on floors 32 & 33, per NFPA 13"},{"number":"CP-2023-000591","date":"2023-02-07","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-10-23","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 48TH FLOOR LEVEL FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2023-000286","date":"2023-02-13","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-08-11","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 47TH FLOOR OF AN EXISTING BUILDING FOR USE AS A BUSINESS OCCUPANCY. ALTERATION TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2023-000353","date":"2023-02-14","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-08-11","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. (CP-2023-000286) Relocate (12) Sprinkler Heads on the 47th fl."},{"number":"MP-2023-000758","date":"2023-02-16","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-08-11","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating (5) diffusers to accommodate new floor plan"},{"number":"PP-2023-001681","date":"2023-02-17","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-08-04","scope":"INSTALL 7 HOT WATER HEATERS, 5 KITCHEN SINKS, 13 LAVATORIES, 2 ELECTRIC WATER COOLERS AND 19 WATER CLOSETS ACCORDING TO THE 2018 PPC."},{"number":"PP-2023-002170","date":"2023-02-20","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-08-11","scope":"Replace One Kitchen Sink utilizing Existing Rough In WITHOUT PIPING"},{"number":"CP-2023-000996","date":"2023-02-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-03-27","scope":"For Level II Alterations on the 48th floor in an existing high-rise structure, Work to include selective demolition & Construction of new partitions, ceilings, lighting fixtures, & finishes as indicated on drawings. As per plans; separate permits required for all MEP/FSP work; no structural work on this permit; building is currently sprinklered throughout in accordance with NFPA 13, with standpipes installed within the exit stairways in accordance with NFPA 14, and with a fire alarm system installed throughout in accordance with NFPA 72; if field conditions vary contact design engineer prior to the start of any work; compliance with Philadelphia Fire and Property Maintenance Codes required prior to occupancy."},{"number":"CP-2023-000998","date":"2023-02-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-10-30","scope":"For Level II Alterations within the existing elevator lobby on the 32nd floor in an existing high-rise structure, as per plans; separate permits required for all MEP/FSP work; no structural work on this permit; building is currently sprinklered throughout in accordance with NFPA 13, with standpipes installed within the exit stairways in accordance with NFPA 14, and with a fire alarm system installed throughout in accordance with NFPA 72; if field conditions vary contact design engineer prior to the start of any work; compliance with Philadelphia Fire and Property Maintenance Codes required prior to occupancy."},{"number":"MP-2023-000572","date":"2023-02-27","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-08-04","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"EP-2023-002052","date":"2023-03-13","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-06-01","scope":"Install fire alarm devices as per drawings as per APPROVED DRAWINGS-2016 nfpa 72."},{"number":"EP-2023-002050","date":"2023-03-13","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-06-02","scope":"Install new panel, receptacles, poke-thrus, lights & light controls as per drawings as per 2017 NEC"},{"number":"EP-2023-001733","date":"2023-03-16","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-07-14","scope":"734 Lighting fixtures 458 Switches 186 1.25” EMT Conduit stub for data outlets 025 1.25” EMT Conduit stub for A/V outlets 066 Dedicated 20 Amp receptacles 175 Duplex receptacles 154 Quadraplex receptacles 025 TV Receptacles 018 Fire rated poke-thru receptacles 020 Power for motorized shades 001 Exhaust fan to wire and connect 008 Insta-hot to wire and connect 002 Dishwashers to wire and connect 047 HVAC units to wire and connect 007 Existing panelboards to connect 001 New panel “UPS” 001 16 kva “UPS” to wire and connect 004 Smoke detectors 013 F/A Strobe lights 090 F/A speaker/strobes 004 F/A SNAC panels to wire and connect 001 F/A Test & recertification as per 2017 NEC and 2016 NFPA 72"},{"number":"EP-2023-002199","date":"2023-03-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-06-21","scope":"Furnish & install (215) Category 6 plenum cables (General) from the MDF/IDF to the customer indicated workstation locations Furnish & install (1) 2-post rack (CPI), with requisite ladder rack, to the customer indicated location within the MDF/IDF Furnish & install (5) Category 6, rack mounted, 48-port patch panels (Panduit NK-unloaded) for the termination of Category 6 cabling within the 7Th Floor IDF Furnish & install (258) Category 6 plenum (General) cables from the MDF/IDF to the customer indicated workstation locations As per 2017 nec"},{"number":"GM-2023-002259","date":"2023-03-23","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2023-11-20","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"EP-2023-002972","date":"2023-04-05","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-06-30","scope":"HORIZONTAL CABLING: Cabling will be Systimax Category 6 riser rated 4-pair and CommScope RG6 quad shield riser rated coax. ? Provide labor to demo voice/data cabling back to the TR, remove Category 5 patch panels and relocate wire managers in MER. ? Provide and install thirteen (13) flush mount dual Category 6 locations. ? Provide and install one hundred two (102) furniture mount dual Category 6 locations. ? Provide and install two (2) floor mount dual Category 6 locations. ? Provide and install four (4) flush mount single coax AV locations. ? Provide and install three (3) flush mount quad Category 6 locations. ? Provide and install Systimax faceplates, floor frames, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables at the workstation location. ? Provide and install eight (8) Systimax Category 6 48-port angled patch panels. These will be installed at the closet location for termination of the 4-pair cables installed. ? The coax cables will be terminated and left coiled at the closet location for final connections by others. ? Provide and install one hundred twenty-three (123) Systimax Category 6 patch cords, 5’ in length (workstation). ? Provide and install one hundred twenty-three (123) Systimax Category 6 patch cords, 7’ in length (workstation). ? Provide and install two hundred forty-six (246) Systimax Category 6 patch cords, 7’ in length (MER). MISCELLANEOUS: ? Provide and install all necessary j-hooks as required to facilitate cable distribution. ? Provide labor and materials to seal all through penetrations of fire rated walls for telecommunications use to maintain necessary fire ratings. ? Bluestone Communications, Inc. will provide labor to test and label all new cabling installed by Bluestone Communications, Inc. throughout the facility. Test results will be submitted as part of the asbuilt package. As per 2017 nec"},{"number":"CP-2023-002588","date":"2023-05-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-04-05","scope":"FOR A LEVEL II INTERIOR ALTERATIONS TO 53RD AND 54TH FLOOR OF AN EXISTING STRUCTURE. FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. **STRUCTURAL ALTERATION TO BE INCLUDED** BUILDING IS FULLY SPRINKLERED.** ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"EP-2023-004788","date":"2023-05-31","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-02-28","scope":"Furnish and install (189) duplex receptacles, (12) dedicated duplex, (22) GFCI receptacles, (18) USB receptacles, (12) quad duplex receptacles, (2) 208 volt 20 amp receptacles,(9) wall furniture feeds, (24) floor boxes, (6) junction box feeds, wiring for (30) VAV's, (3) water heaters, relocate one 100 amp panel, install new 100 amp panel. Furnish and install 500 lights as per 2017 NEC."},{"number":"PP-2023-006941","date":"2023-05-31","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-04-05","scope":"INSTALL 2 WATER CLOSETS, 2 LAVATORIES, 6 PANTRY SINKS, 2 ELECTRIC WATER COOLERS, 2 FLOOR DRAINS, 3 HOT WATER HEATERS, 4 DRAIN BOXES, 6 SUPPLY OUTLET BOXES, 1 COFFEE MAKER AND ICE MAKER ACCORDING TO THE 2018 PPC AND PER PLANS."},{"number":"FP-2023-001233","date":"2023-06-05","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-04-05","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 397 SPRINKLER HEADS AS PER NFPA 13"},{"number":"MP-2023-002674","date":"2023-07-05","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-04-05","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUTS ON THE 53RD AND 54TH FLOORS OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. *2018 IMC REVIEW*"},{"number":"CP-2023-004086","date":"2023-07-27","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2025-06-10","scope":"FOR A LEVEL II INTERIOR ALTERATION TO AN EXISTING TENANT SPACE LOCATED ON THE 47TH FLOOR OF AN EXITING BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF NEW WALL PARTITIONS AND TO PROVIDE FINISHES AND FURNISHINGS THROUGHOUT THE DESIGNATED AREA . ALL WORK TO BE DONE PER APPROVED PLANS.**BUILDING IS FULLY SPRINKLERED **IEBC 2018** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**ANY DEVIATION TO THE APPROVED SCOPE OF WORK WILL REQUIRED AN AMENDED PERMIT**"},{"number":"EP-2023-005640","date":"2023-08-01","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-02-28","scope":"Furnish and install 9 wall strobes, 30 ceiling speaker strobes, one wall speaker strobe, one booster panel as per 2016 NFPA 72."},{"number":"EP-2023-007309","date":"2023-08-03","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-11-27","scope":"• Provide and install twenty-four (24) surface mount dual Category 6A wireless access point locations. • Provide labor to install twenty-four (24) customer-provided wireless access points. • Provide and install fifty-four (54) flush mount dual Category 6A locations. • Provide and install one (1) flush mount quad Category 6A location. • Provide and install one hundred thirty-seven (137) furniture mount dual Category 6A locations. • Provide and install two (2) floor mount dual Category 6A locations. • Provide and install eight (8) ceiling mount single Category 6A locations. • Provide and install two (2) floor mount quad Category 6A locations. • Provide and install eighteen (18) flush mount quad (3 Category 6A/1 coax) locations. • Provide and install two (2) ceiling mount dual Category 6A locations. • Provide and install six (6) ceiling mount quad (3 Category 6A/1 coax) locations. • Provide and install one (1) flush mount triple Category 6A location. • Provide and install CommScope faceplates, surface mount boxes, floor frames, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables installed at the workstation location. • Provide and install twelve (12) CommScope Category 6A 48-port patch panels, each loaded with the required modular jacks, with two (2) Chatsworth 1RU horizontal wire managers and twelve (12) CommScope patch panel strain relief bars. These will be installed at the required closet location for termination of the 4-pair cables installed. • The coax cables will be terminated and left coiled at the closet location for final connections by others. FIBER BACKBONE CABLING: • Provide and install one (1) Corning 12-strand OM4 multimode armored plenum rated fiber optic cable from the MDF to the IDF. • Provide and install twenty-four (24) Corning LC multimode connectors. These will be installed for termination of each strand of fiber optic cable installed. • Provide and install two (2) Corning"},{"number":"CP-2023-004276","date":"2023-08-25","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-03-07","scope":"FOR LEVEL I ALTERATIONS TO THE EXISTING 20TH FLOOR TENANT SPACE AS PER APPLICATION/PLANS AND IN ACCORDANCE WITH THE 2018 IBC. NO CHANGES TO MEANS OF EGRESS OR OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MEP WORK."},{"number":"EP-2023-008250","date":"2023-08-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-11-13","scope":"Install Lighting and Power"},{"number":"CP-2023-005048","date":"2023-09-11","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-03-18","scope":"FOR THE RENOVATION OF A RESTROOM AREA LOCATED ON THE 9TH AND 30TH FLOOR OF AN EXISTING STRUCTURE.**ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.**"},{"number":"GM-2023-008414","date":"2023-09-18","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2024-03-19","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"EP-2023-009086","date":"2023-09-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-06-10","scope":"HORIZONTAL CABLING: Cabling will be Systimax Category 6 riser rated 4-pair and CommScope RG6 quad shield riser rated coax. ? Provide labor to demo voice/data cabling back to the TR, remove Category 5 patch panels and relocate wire managers in MER. ? Provide and install thirteen (13) flush mount dual Category 6 locations. ? Provide and install one hundred two (102) furniture mount dual Category 6 locations. ? Provide and install two (2) floor mount dual Category 6 locations. ? Provide and install four (4) flush mount single coax AV locations. ? Provide and install three (3) flush mount quad Category 6 locations. ? Provide and install Systimax faceplates, floor frames, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables at the workstation location. ? Provide and install eight (8) Systimax Category 6 48-port angled patch panels. These will be installed at the closet location for termination of the 4-pair cables installed. ? The coax cables will be terminated and left coiled at the closet location for final connections by others. ? Provide and install one hundred twenty-three (123) Systimax Category 6 patch cords, 5’ in length (workstation). ? Provide and install one hundred twenty-three (123) Systimax Category 6 patch cords, 7’ in length (workstation). ? Provide and install two hundred forty-six (246) Systimax Category 6 patch cords, 7’ in length (MER). AS PER NEC 2017"},{"number":"EP-2023-008956","date":"2023-09-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-11-16","scope":"Install receptacles, lights & light controls as per drawings-2017 NEC. **Separate fire alarm permit req'd.**"},{"number":"PP-2023-013235","date":"2023-09-25","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-03-07","scope":"• Furnish and install [2] Kitchen Sinks, • Provide labor and materials to modify existing sanitary and water to accommodate new sink."},{"number":"MP-2023-003964","date":"2023-10-04","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-11-20","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating (9) air diffusers"},{"number":"FP-2023-002436","date":"2023-10-12","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-11-20","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (6) sprinkler heads to accommodate interior alterations on 47th floor"},{"number":"EP-2023-009803","date":"2023-10-19","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-11-16","scope":"Install fire alarm devices as per drawings -2016 NFPA-72."},{"number":"EP-2023-009945","date":"2023-10-23","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-03-05","scope":"Install 21 light fixtures, 8 switch. Install fire alarm notification appliances. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72."},{"number":"GM-2023-010281","date":"2023-11-15","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2024-02-21","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"EP-2023-011209","date":"2023-12-01","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-12-08","scope":"Provide and install 1 Camera to 8 locations. Provide and install plenum composite cable to 12 doors. Terminate and test all cabling. All work will be completed per 2017 NEC. No rescue systems work."},{"number":"CP-2023-006629","date":"2024-01-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-01-27","scope":"FOR A LEVEL II INTERIOR ALTERATIONS (NO CHANCGE IN OCCUPANCY) TO ACCOMMODATE THE 38TH, 39TH AND 40TH FLOOR LEVEL OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE SELECTIVE DEMOLITION OF EXISTING PARTITIONS AND THE ERECTION OF NEW PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. **INTERIOR STAIRWAYS NOT PART OF THE REVIEW **BUILDING IS FULLY SPRINKLERED.** ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.** AMENDED AS OF 3/28/2024 TO INCLUDE THE STEEL WORK FOR THE COMMUNICATING STAIRS BETWEEN THE 28TH ,39TH AND 40TH FLOOR.** WORK APPROVED UNDER PA-2024-6902 WITH MI-2023-6689**"},{"number":"FP-2024-000164","date":"2024-01-30","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-01-27","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. NO NEW MAINS, CROSS MAINS OR EXTENDING THE COUNT OF THE EXISTING HEAD-TO ADD MORE."},{"number":"PP-2024-001823","date":"2024-02-15","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-01-27","scope":"INSTALL 13 KITCHEN SINKS, 12 SUPPLY OUTLET BOXES, 5 HOT WATER HEATERS, 1 DISHWASHER, 1 ICE MAKER, 5 LAVATORIES, 5 WATER CLOSETS, 3 FLOOR SINKS AND 14 FLOOR DRAINS ACCORDING TO THE 2018 PPC AND PER PLANS."},{"number":"CP-2024-001079","date":"2024-03-19","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-06-10","scope":"FOR LEVEL I ALTERATIONS TO INCLUDE INSTALLATION OF NEW DOOR IN AN EXISTING DOOR OPENING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2024-002985","date":"2024-03-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-01-08","scope":"INSTALLATION TELECOMMJNICATION WIRING ACCORDING TO THE 2017 NEC."},{"number":"MP-2024-000175","date":"2024-04-01","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-01-27","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"EP-2024-002461","date":"2024-04-01","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-12-11","scope":"Install 1325 light fixture, 55 exit, 3 inverter, 274 switch, 3 time clock, 774 receptacle, 31 furniture power, 44 equipment power, 101 HVAC power only, 1 208/120 volt panel as per 2017 NEC. Fire Alarm: Install 90 speaker/strobe, 22 strobe, 11 smoke detector, 3 relay, 2 door holder, 3 booster panel as per 2016 NFPA 72."},{"number":"EP-2024-003746","date":"2024-05-02","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-05-16","scope":"Furnish and install (2) High Power Control Relay Modules for fire alarm system as per drawings and 2016 NFPA 72."},{"number":"CP-2024-002567","date":"2024-05-28","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-10-22","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING BUSINESS OCCUPANCY AT SUITE 3500 WITHIN AN EXISTING HISE RISE BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2024-001110","date":"2024-06-06","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-10-24","scope":"FOR LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 51ST FLOOR OFFICE SPACE WITHIN AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"EP-2024-005025","date":"2024-06-10","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-24","scope":"ISTALL (7) ADDITIONAL FIRE ALARM DEVICES ON THE EXISTING FIRE ALARM SYSTEM. ALL WORK IN ACCORDANCE WITH THE 2017 NEC."},{"number":"FP-2024-001314","date":"2024-06-28","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-10-22","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 7 sprinkler heads"},{"number":"EP-2024-007043","date":"2024-07-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-24","scope":"Furnish and install 4 duplex outlets, 4 quad outlets, one floor core, 6 F-1 and 4 F-2, 3 ceiling motions and 4 dimmers Fire Alarm as per drawings. This is adding new devices to the existing fire alarm -2017 NEC, 2016 NFPA-72."},{"number":"CP-2024-004136","date":"2024-08-07","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-01-29","scope":"FOR LEVEL II INTERIOR ALTERATIONS (DEMOLITION OF NON-LOADBEARING PARTITIONS) AT THE 31ST AND 37TH FLOORS TO CREATE VACANT SHELL SPACES. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK."},{"number":"MP-2024-003642","date":"2024-08-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-10-22","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES."},{"number":"FP-2024-001765","date":"2024-08-20","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-01-29","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (138) SPRINKLER HEADS AS PER NFPA 13"},{"number":"PP-2024-011740","date":"2024-08-23","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-01-29","scope":"Swapping Old Fixtures for New 32 FIXTURES (16) Water Closets (4) urinals (12) Lavs 31st & 37th Floor Restrooms"},{"number":"MP-2024-003895","date":"2024-08-30","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-01-29","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. Relocating (12) GRDs to accommodate a new wall layout"},{"number":"EP-2024-008262","date":"2024-09-09","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-01-10","scope":"Furnish and install temporary 2x2 fixtures throughout space utilizing existing circuitry -FOR DEMO ,AND HAVE gfci PROTECTION PER: 590.6 Ground-Fault Protection for Personnel (VACANT SHELL SPACES) . **SEPARATE ELECTRICAL PERMITS REQ'D FOR FIRE ALARM AND FITOUT**"},{"number":"CP-2024-004118","date":"2024-09-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-01-31","scope":"FOR THE RENOVATIONS OF A RESTROOM AREA LOCATED ON THE 37th AND 43rd FLOOR OF AN EXISTING STRUCTURE. **ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. **"},{"number":"CP-2024-004716","date":"2024-09-13","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-02-20","scope":"FOR LEVEL II ALTERATIONS TO EXISTING BUSINESS OCCUPANCY AT SUITE 665, 1200 AND 1300, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"PP-2024-012972","date":"2024-09-24","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-01-31","scope":"Replacing OF FIXTURES WITHOUT PIPING (12) LAVs, (16) Water Closets, (4) Urinals utilizing existing rough in"},{"number":"CP-2024-004679","date":"2024-09-25","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2026-05-05","scope":"FOR THE REMOVAL OF EXISTING COMMUNICATING STAIRS BETWEEN LEVELS 11-12 AND 13-14 AND INFILL OF THE EXISTING FLOOR OPENINGS AS PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"MP-2024-004322","date":"2024-09-25","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-01-31","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (12) Diffusers to accommodate new floor plan"},{"number":"FP-2024-002178","date":"2024-10-11","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2026-05-05","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (6) sprinkler heads to accommodate interior alterations"},{"number":"PP-2024-014918","date":"2024-10-29","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-02-20","scope":"Supplying (5) Shut off boxes and (5) Water Filters in existing kitchens"},{"number":"EP-2024-010327","date":"2024-10-30","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-01-30","scope":"Furnish & Install Power and Lighting Per Plans. amendment: Install fire alarm . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC."},{"number":"MP-2024-004929","date":"2024-11-25","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-02-19","scope":"FOR ALTERATION TO THE EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT AS PER APPROVED PLANS."},{"number":"FP-2024-002494","date":"2024-11-26","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-02-19","scope":"EZ SPRINKLER HEAD RELOCATION DOCUMENT SIGNED - Please upload the MOST RECENT EZ-Standard sprinkler head relocation form, both pages signed, acknowledging the standard. We will complete processing your Application as soon as the EZ-Standard Statement is received. Relocate (39) sprinklers on 6th, 12th, and 13th floors to accommodate interior alterations"},{"number":"EP-2025-000324","date":"2025-01-14","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-01-21","scope":"One-for-one swap-out of 12 L-1, 84 feet L-2, and 4 GFI's."},{"number":"CP-2025-000892","date":"2025-03-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-08-20","scope":"FOR A LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 51ST FLOOR LEVEL OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS .BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"MP-2025-001803","date":"2025-03-25","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-08-20","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. relocate [1] existing thermostat, relocate [5] existing diffusers, and provide air balance. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies."},{"number":"EP-2025-002059","date":"2025-03-27","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-04-30","scope":"Reinstall (4) relocated duplex outlets in new demising wall, install (1) wall motion sensor, and relocate (3) 2x4 fixtures as per 2017 NEC."},{"number":"CP-2025-001573","date":"2025-04-08","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-09-05","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING OFFICE SPACE ON THE 51ST FLOOR, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2025-000863","date":"2025-04-24","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-09-05","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (29) SPRINKLER HEADS ON THE 51st FLOOR, PER NFPA 13"},{"number":"PP-2025-005427","date":"2025-04-24","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-09-05","scope":"• Provide labor and material to disconnect [1] sink and [1] water heater. All debris is to be dropped to the floor for removal by others • Furnish and install [1] Pantry Sink, [1] Electric Water Heater, [1] Open Site Drain, • Provide labor and materials to extend from existing sanitary, VENT and domestic cold water as shown"},{"number":"EP-2025-003981","date":"2025-04-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-08-21","scope":"Cabling will be CommScope Category 6 plenum rated 4-pair. • Provide and install two (2) flush mount single locations. • Provide and install one (1) floor mount dual location. • Provide and install eight (8) flush mount dual locations. • Provide and install nine (9) furniture mount dual locations. • Provide and install CommScope faceplates, floor frames and modular jacks as required for termination of the 4-pair cables at the workstation location. • Provide and install one (1) CommScope Category 6 48-port patch panel. This will be installed at the appropriate closet location for termination of the 4-pair cables installed. • Provide and install all necessary j-hooks as required to facilitate cable distribution. • Provide labor and materials to seal all through penetrations of fire rated walls for telecommunications use to maintain necessary fire ratings. • Bluestone Communications, Inc. will provide labor to test and label all new cabling installed by Bluestone Communications, Inc. throughout the facility. Test results will be submitted as part of the asbuilt package."},{"number":"MP-2025-002515","date":"2025-05-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-09-05","scope":"FOR THE INSTALLATION OF VAVs, GRDs, AND ASSOCIATED DUCTWORK AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2025-001573 FOR ASSOCIATED BUILDING PERMIT."},{"number":"EP-2025-004662","date":"2025-05-23","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-09-02","scope":"Furnish and Install 24-duplex outlets, 11-quad outlets,2-GFI outlet,3-floor cores,1-dedicated outlet,18-ring and strings, 44-F1,26-F3,5-F4,3-F5,2-F6,1-F7,4-Exits,1-Hot water heater feed, 6-FPV as per 2017 NEC. Fire alarm as per drawing and 2016 NFPA 72."},{"number":"CP-2025-002887","date":"2025-06-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-02-27","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SUITE 3100 ON THE 31ST FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"PP-2025-009004","date":"2025-07-16","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2026-02-26","scope":"• Furnish and install [2] Pantry Sinks, [1] Electric Water Heater, [1] Floor Drain and [1] Hub Drain • Provide labor and materials to extend from existing sanitary, vent and domestic water."},{"number":"EP-2025-007346","date":"2025-08-01","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-10-02","scope":"Rough-In Permit for EP-2025-007342 Power, teledata, lighting and lighting controls as per attached drawings. Contract value $740,635.00= $701,635 for electrical and teledata portion of work and $39,000 for fire alarm portion of work. FA will be applied for at a later date."},{"number":"FP-2025-001508","date":"2025-08-07","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-02-26","scope":"FOR THE INSTALLATION OF NEW SPRINKLER HEADS AND THE RELOCATION OF SPRINKLER HEADS IN ACCORDANCE WITH NFPA 13 THROUGHOUT THE 31ST FLOOR LEVEL WITH EXISTING 6\" BACKFLOW PREVENTION ASSEMBLY. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA."},{"number":"EP-2025-007808","date":"2025-08-12","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-08-25","scope":"Rough-In Permit for EP-2025-007807 Reconfigure existing fire alarm as per the attached drawings."},{"number":"EP-2025-007807","date":"2025-08-19","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-12-11","scope":"Reconfigure existing fire alarm as per the attached drawings and 2016 NFPA 72. This is only for the fire alarm portion of work."},{"number":"EP-2025-007342","date":"2025-09-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-12-11","scope":"Install power, tele/data, lighting, and lighting controls as per attached drawings and 2017 NEC."},{"number":"CP-2025-004540","date":"2025-09-19","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-03-06","scope":"FOR A LEVEL II INTERIOR ALTERATIONS ( NO CHANGE IN OCCUPANCY) TO A PORTION OF THE 28TH FLOOR OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE DEMOLITION OF EXISTING PARTITIONS AND THE ERECTION OF NEW PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ** ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"MP-2025-003775","date":"2025-09-19","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-02-26","scope":"FOR THE INSTALLATION OF HVAC APPLIANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS TO THE 31ST FLOOR OF AN EXISTING STRUCTURE PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS. *2018 IMC REVIEW*"},{"number":"FP-2025-001982","date":"2025-09-25","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-03-06","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (14) SPRINKLER HEADS ON THE 28TH FLOOR, PER NFPA 13"},{"number":"MP-2025-004925","date":"2025-10-02","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-03-06","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND WITH ASSOCIATED DUCTWORK TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2025-009293","date":"2025-10-15","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-01-28","scope":"Relocate 20 light fixtures. Install 24 light fixtures, 2 exit, 3 switches, 8 receptacles, and provide power to 1 shade as per 2017 NEC. Fire Alarm: Install 1 speaker/strobe and relocate 1 speaker/strobe as per 2016 NFPA 72."},{"number":"MP-2025-005087","date":"2025-10-17","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Issued","completedDate":null,"scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2025-004541","date":"2025-10-22","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-03-18","scope":"FOR LEVEL I ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE PROVIDING FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ** NO CERTIFICATE OF OCCUPANCY REQUIRED FOR THIS WORK. ALTERATIONS SHALL BE DONE IN A MANNER THAT DOES NOT IMPACT THE EGRESS OR THE LEVEL OF FIRE PROTECTION PROVIDED AS PER SECTION A-701.1 (EXCEPTION 2) OF THE PHILADELPHIA ADMINISTRATIVE CODE **"},{"number":"PP-2025-014002","date":"2025-10-28","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2026-03-18","scope":"Remove and replace (32) plumbing fixtures, (12) lavatories, (14) water closets and (6) urinals connecting to existing piping. *WITHOUT PIPING*"},{"number":"CP-2025-005740","date":"2025-11-25","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-04-09","scope":"FOR A LEVEL II INTERIOR ALTERATIONS TO AN EXISTING STRUCTURE. FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE SELECTIVE DEMOLITION OF EXISTING PARTITION AND THE ERECTION OF NEW PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"PP-2025-015414","date":"2025-12-02","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2026-04-08","scope":"Furnish and install (2) plumbing fixtures, (1) kitchen sink and (1) hot water heater, with piping. ALL WORK PER 2018 PPC AND EZ STANDARD"},{"number":"EP-2025-010693","date":"2025-12-10","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"Rework Chillers #1, 2 & 4 with Conduit and Wire - Rework Pumps 8, 9 & 10 with Conduit and Wire - Control Conduit and Wiring for the Same Units - Disconnect and Reconnect EF-4 .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **MP-2025-005087**"},{"number":"FP-2025-002442","date":"2025-12-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-04-08","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 18 Heads"},{"number":"CP-2025-005658","date":"2025-12-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR INTERIOR DEMOLITION AND RESTROOM ALTERATIONS (WITH NO CHANAGE OF OCCUPANCY) PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"EP-2025-011515","date":"2025-12-18","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-03-26","scope":"Furnish and install wiring for one hot water heater, one VAV, 4 FPV, five duplex receptacles, 4 quads, 2 dedicated receptacles, 20 light fixtures, lighting controls, relocate 30 existing light fixtures and fire alarm as per drawings In accordance with the NFPA72 2016 & The Philadelphia fire code 2018"},{"number":"MP-2025-006209","date":"2025-12-22","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-04-08","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"PP-2025-016472","date":"2025-12-29","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2026-03-18","scope":"• Provide labor and material to disconnect [8] water closets, [7] lavatories, [3] urinals on the 6th Floor Core Restroom • Provide labor and material to disconnect [6] water closets, [5] lavatories, [2] urinals on 56th Floor Core Restroom"},{"number":"EP-2025-012288","date":"2026-01-12","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-03-11","scope":"Furnish and install 6 F1, 215 F2, 3 F3, 19 F4, 27 F5, 2 F6, 2 F7 light fixtures 1 for 1 swap using existing circuitry. Replace 73 ceiling occupancy sensors in kind as per 2017 NEC."},{"number":"FP-2025-002533","date":"2026-01-13","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-04-21","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 97 sprinkler heads"},{"number":"MP-2026-000684","date":"2026-02-06","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-04-21","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 14 exhaust grilles only, then provide air balance report."},{"number":"EP-2025-012296","date":"2026-03-02","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-04-13","scope":"Installation of New lighting and lighting sensors. Installation of new speakers. Replacement of strobes 1 for one. changing color from red to white. Temporary power and lighting NEC 2017"},{"number":"GM-2026-003894","date":"2026-05-11","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Issued","completedDate":null,"scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2026-002238","date":"2026-05-21","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR LEVEL II INTERIOR ALTERATIONS TO THE VACANT THIRD FLOOR TO ACCOMODATE EXPANSION OF BUILDING AMENITIES/ OFFICE SPACE PER APPROVED PLANS. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/ FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2026-002137","date":"2026-05-21","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2026-07-14","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2026-001008","date":"2026-05-28","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Issued","completedDate":null,"scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (65) SPRINKLER HEADS, PER NFPA 13"},{"number":"EP-2026-004790","date":"2026-05-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-07-09","scope":"Relocate 18 light fixture, 6 switch. Install 3 light fixture, 3 switch, 9 receptacle, 9 CAT-6 cables."},{"number":"PP-2026-007319","date":"2026-06-05","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Issued","completedDate":null,"scope":"Install (2) plumbing fixtures, (1) kitchen sink and (1) hot water heater, connecting to existing piping."},{"number":"EP-2026-004808","date":"2026-06-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"Furnish and install 43 duplex outlets, 9 quad outlets, 4 GFI's, 6 TV outlets, 2 projector outlets, 9 floor cores, 3 wall furniture feeds, 1 hot water heater, 7 fan power boxes, 70' L-1, 22 L-2, 32 L-3, 6 L-4, 4 L-5, 3 L-6, 45 L-7, 3 L-8, 3 L-9, 14 L-10, 6 L-11, 1 L-12, 8 exits, 2 dimmers, 8 wall occupancy sensors, 15 ceiling sensors ,Fire Alarm ALL NWORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72."},{"number":"MP-2026-003163","date":"2026-06-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Issued","completedDate":null,"scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"MP-2026-003048","date":"2026-06-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2026-07-14","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, WITH ASSOCIATED DUCTWORK TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2026-001414","date":"2026-07-07","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2026-07-14","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (9) SPRINKLER HEADS, PER NFPA 13"}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2026,"k":"permit","w":"Interior Non-Load-Bearing Wall Demo."},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Addition and/or Alterations"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Alterations"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Addition and/or Alterations"},{"y":2026,"k":"permit","w":"Addition and/or Alterations"},{"y":2026,"k":"viol","w":"13 L&I violations incl UNSAFE STRUCTURE"},{"y":2026,"k":"permit","w":"Addition and/or Alterations"},{"y":2026,"k":"insp","w":"L&I: 4 failed, 2 passed"}],"rented":false,"licenses":[{"number":"200262","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"RICHERB INC","legalName":"RICHERB INC","address":"1650 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2001-02-28","latestIssueDate":"2001-02-28","expirationDate":"2002-04-30","inactiveDate":null},{"number":"199107","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"FABER COE & GREGG OF PA INC (PHILLY NEWS NOW)","legalName":"FABER COE & GREGG OF PA INC","address":"1650 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2002-04-18","latestIssueDate":"2002-04-18","expirationDate":"2003-04-30","inactiveDate":null},{"number":"200815","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"SHIRISH PATEL (GATEWAY NEWSSTAND)","legalName":"SHIRISH PATEL","address":"1650 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2004-03-26","latestIssueDate":"2012-05-08","expirationDate":"2013-04-30","inactiveDate":null},{"number":"207889","type":"Food Preparing and Serving","status":"Active","businessName":"LIBERTY PLACE MW INC","legalName":"LIBERTY PLACE MW INC","address":"1650 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2004-04-23","latestIssueDate":"2026-03-16","expirationDate":"2027-04-30","inactiveDate":null},{"number":"209685","type":"Food Caterer","status":"Inactive","businessName":"BROCK & CO INC","legalName":"BROCK & CO INC","address":"1650 MARKET ST","revenueCode":"3122","rentalCategory":null,"units":null,"issuedDate":"2004-04-29","latestIssueDate":"2005-06-04","expirationDate":"2006-04-30","inactiveDate":"2012-12-22"},{"number":"299125","type":"High Rise","status":"Inactive","businessName":"PHILA LIBERTY PLACE (SUNBELT MANAGEMENT CO)","legalName":"PHILA LIBERTY PLACE","address":"1650 MARKET ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2004-04-29","latestIssueDate":"2008-05-29","expirationDate":"2010-04-30","inactiveDate":"2010-04-15"},{"number":"286053","type":"Public Garage / Parking Lot","status":"Active","businessName":"KWIK PARK CORP","legalName":"KWIK PARK CORP","address":"1650 MARKET ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2004-12-16","latestIssueDate":"2025-12-15","expirationDate":"2026-12-31","inactiveDate":null},{"number":"286431","type":"Hazardous Materials","status":"Inactive","businessName":"PHILA LIBERTY PLACE LP","legalName":"PHILA LIBERTY PLACE LP","address":"1650 MARKET ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2005-01-06","latestIssueDate":"2008-11-30","expirationDate":"2009-11-30","inactiveDate":null},{"number":"457346","type":"Food Preparing and Serving","status":"Inactive","businessName":"BSC SERVICES CORP (EUREST COFFEE BAR)","legalName":"BSC SERVICES CORP","address":"1650 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2008-09-25","latestIssueDate":"2008-09-25","expirationDate":"2009-04-30","inactiveDate":"2012-12-22"},{"number":"505406","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"BROWN BETTY DESSERT BOUTIQUE LLC","legalName":"BROWN BETTY DESSERT BOUTIQUE LLC","address":"1650 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2010-06-14","latestIssueDate":"2014-05-24","expirationDate":"2015-04-30","inactiveDate":"2015-06-29"},{"number":"528477","type":"High Rise","status":"Active","businessName":"PHILADELPHIA LIBERTY PLACE LP","legalName":"PHILADELPHIA LIBERTY PLACE LP","address":"1650 MARKET ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2011-03-23","latestIssueDate":"2026-06-26","expirationDate":"2027-04-30","inactiveDate":null},{"number":"597689","type":"Hazardous Materials","status":"Inactive","businessName":"GREATER BOSTON RADIO INC","legalName":"GREATER BOSTON RADIO INC","address":"1650 MARKET ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2013-08-09","latestIssueDate":"2018-02-01","expirationDate":"2017-12-31","inactiveDate":"2015-03-01"},{"number":"670000","type":"Food Preparing and Serving","status":"Closed","businessName":"HEATHLAND HOSPITALITY GROUP","legalName":"HEATHLAND HOSPITALITY GROUP","address":"1650 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2015-07-02","latestIssueDate":"2018-02-07","expirationDate":"2018-04-30","inactiveDate":null},{"number":"774389","type":"Food Preparing and Serving (30+ SEATS)","status":"Active","businessName":"HEATHLAND HOSPITALITY GROUP","legalName":"HEATHLAND HOSPITALITY GROUP","address":"1650 MARKET ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2018-04-26","latestIssueDate":"2026-04-14","expirationDate":"2027-04-30","inactiveDate":null},{"number":"787608","type":"Food Establishment, Retail Permanent Location","status":"Closed","businessName":"Event Network, LLC (Philly From the Top )","legalName":"Event Network, LLC","address":"1650 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2018-08-29","latestIssueDate":"2019-07-22","expirationDate":"2020-08-28","inactiveDate":null}],"licenseActivity":[{"number":"787608","type":"Food Establishment, Retail Permanent Location","businessName":"Event Network, LLC (Philly From the Top )","legalName":"Event Network, LLC","issuedDate":"2018-08-29","latestIssueDate":"2019-07-22","closureDate":"2020-08-28","expirationDate":"2020-08-28","inactiveDate":null,"status":"Closed","statusLabel":"Closed","active":false},{"number":"774389","type":"Food Preparing and Serving (30+ SEATS)","businessName":"HEATHLAND HOSPITALITY GROUP","legalName":"HEATHLAND HOSPITALITY GROUP","issuedDate":"2018-04-26","latestIssueDate":"2026-04-14","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"670000","type":"Food Preparing and Serving","businessName":"HEATHLAND HOSPITALITY GROUP","legalName":"HEATHLAND HOSPITALITY GROUP","issuedDate":"2015-07-02","latestIssueDate":"2018-02-07","closureDate":"2018-04-30","expirationDate":"2018-04-30","inactiveDate":null,"status":"Closed","statusLabel":"Closed","active":false},{"number":"597689","type":"Hazardous Materials","businessName":"GREATER BOSTON RADIO INC","legalName":"GREATER BOSTON RADIO INC","issuedDate":"2013-08-09","latestIssueDate":"2018-02-01","closureDate":"2015-03-01","expirationDate":"2017-12-31","inactiveDate":"2015-03-01","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"528477","type":"High Rise","businessName":"PHILADELPHIA LIBERTY PLACE LP","legalName":"PHILADELPHIA LIBERTY PLACE LP","issuedDate":"2011-03-23","latestIssueDate":"2026-06-26","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"505406","type":"Food Establishment, Retail Permanent Location","businessName":"BROWN BETTY DESSERT BOUTIQUE LLC","legalName":"BROWN BETTY DESSERT BOUTIQUE LLC","issuedDate":"2010-06-14","latestIssueDate":"2014-05-24","closureDate":"2015-06-29","expirationDate":"2015-04-30","inactiveDate":"2015-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"457346","type":"Food Preparing and Serving","businessName":"BSC SERVICES CORP (EUREST COFFEE BAR)","legalName":"BSC SERVICES CORP","issuedDate":"2008-09-25","latestIssueDate":"2008-09-25","closureDate":"2012-12-22","expirationDate":"2009-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"286431","type":"Hazardous Materials","businessName":"PHILA LIBERTY PLACE LP","legalName":"PHILA LIBERTY PLACE LP","issuedDate":"2005-01-06","latestIssueDate":"2008-11-30","closureDate":"2009-11-30","expirationDate":"2009-11-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"286053","type":"Public Garage / Parking Lot","businessName":"KWIK PARK CORP","legalName":"KWIK PARK CORP","issuedDate":"2004-12-16","latestIssueDate":"2025-12-15","closureDate":null,"expirationDate":"2026-12-31","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"209685","type":"Food Caterer","businessName":"BROCK & CO INC","legalName":"BROCK & CO INC","issuedDate":"2004-04-29","latestIssueDate":"2005-06-04","closureDate":"2012-12-22","expirationDate":"2006-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"299125","type":"High Rise","businessName":"PHILA LIBERTY PLACE (SUNBELT MANAGEMENT CO)","legalName":"PHILA LIBERTY PLACE","issuedDate":"2004-04-29","latestIssueDate":"2008-05-29","closureDate":"2010-04-15","expirationDate":"2010-04-30","inactiveDate":"2010-04-15","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"207889","type":"Food Preparing and Serving","businessName":"LIBERTY PLACE MW INC","legalName":"LIBERTY PLACE MW INC","issuedDate":"2004-04-23","latestIssueDate":"2026-03-16","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"200815","type":"Food Establishment, Retail Permanent Location","businessName":"SHIRISH PATEL (GATEWAY NEWSSTAND)","legalName":"SHIRISH PATEL","issuedDate":"2004-03-26","latestIssueDate":"2012-05-08","closureDate":"2013-04-30","expirationDate":"2013-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"199107","type":"Food Establishment, Retail Permanent Location","businessName":"FABER COE & GREGG OF PA INC (PHILLY NEWS NOW)","legalName":"FABER COE & GREGG OF PA INC","issuedDate":"2002-04-18","latestIssueDate":"2002-04-18","closureDate":"2003-04-30","expirationDate":"2003-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"200262","type":"Food Establishment, Retail Permanent Location","businessName":"RICHERB INC","legalName":"RICHERB INC","issuedDate":"2001-02-28","latestIssueDate":"2001-02-28","closureDate":"2002-04-30","expirationDate":"2002-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"record-pressure","level":"elevated","title":"Records to verify together","summary":"More than one separately dated public record deserves a current-status check.","evidence":["12 open L&I violations","failed L&I inspection activity in 2022, 2024, 2026"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."},{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["10 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Appeal #1718: OPEN · Granted. Use permit #101948: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"38 permits not marked completed: 120524 (Expired), 123587 (Expired), 124518 (Expired), 125713 (Expired), 303841 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"12 open L&I violations","finding":"72 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"building-certifications","level":"attention","title":"A life-safety certification appears expired","finding":"Facade Report: Safe with Repair through Apr 25, 2029; Fire Alarm Certification: Certified through Oct 30, 2026; Sprinkler Certification: Certified through Dec 15, 2026; Damper Certification: Certified through Sep 30, 2025; Smoke Control Certification: Certified through Apr 29, 2025; Special Hazards Certification: Certified through Oct 16, 2026; Emergency and Standby Power Systems Certification: Certified through Nov 15, 2026","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"18 failed, 32 passed, and 0 CLOSED investigation outcomes are in the fetched history; the latest dated visit was FAILED on Jun 3, 2026.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Establishment, Retail Permanent Location #200262: Inactive; Food Establishment, Retail Permanent Location #199107: Inactive; Food Establishment, Retail Permanent Location #200815: Inactive; Food Caterer #209685: Inactive since Dec 22, 2012","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}