{"asOf":"2026-07-26T16:00:47.742Z","block":"1600-1699 WALNUT ST","blockUrl":"https://philadelphia.blockreport.homes/block/1600-1699-walnut-st","address":"1619-21 WALNUT ST","parcelNumber":"883043300","source":"https://property.phila.gov/?p=883043300","ownerType":"investor","kind":"offices","isHouse":false,"home":false,"commercial":true,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"DB0","buildingCodeNew":"241","buildingClass":"OFF BLD COM NO GAR MASON","buildingClassNew":"OFFICE BLDNG - Low Rise","useLabel":"Offices","owner":"WALNUT STREET RETAIL INVE","coOwner":null,"marketValue":8106000,"landAssessment":1621200,"improvementAssessment":6484800,"livableArea":42624,"yearBuilt":1937,"lastSale":{"price":7100000,"date":"2007-12-13T05:00:00Z"},"openViolations":2,"violations":[{"number":"1382346","date":"2009-06-03","code":"PM-308.1/11","title":"WALL PARTIALLY COLLAPSED ID","status":"COMPEXCP","resolutionDate":null,"resolution":null},{"number":"1382347","date":"2009-06-03","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPEXCP","resolutionDate":null,"resolution":null},{"number":"1495901","date":"2009-10-16","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1495902","date":"2009-10-16","code":"PM-311.0/2","title":"EXT-GRAFFITI","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2736968","date":"2013-03-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2736969","date":"2013-03-11","code":"FC-901.6/12","title":"FIRE DEPT CONNECT REP DAM CAPS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2967373","date":"2013-03-20","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2967371","date":"2013-03-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2967372","date":"2013-03-20","code":"FC-405.2/2","title":"EVAC DRILL-GRP B HI RISE-2X/YR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2967374","date":"2013-03-20","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2867378","date":"2013-07-18","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"ERROR","resolutionDate":null,"resolution":null},{"number":"2962534","date":"2013-10-04","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2962533","date":"2013-10-04","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070569","date":"2014-01-23","code":"FC-605.4/1","title":"FIRE-ELECT MULTIPLUG PROHIB","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070572","date":"2014-01-23","code":"FC-607.3/1","title":"ELEVATOR KEY LOCATION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070576","date":"2014-01-23","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070575","date":"2014-01-23","code":"FC-907.20/1","title":"FA-TEST REQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070574","date":"2014-01-23","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070573","date":"2014-01-23","code":"FC-703.1/5","title":"FIRE-DOOR/HARDWARE MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070566","date":"2014-01-23","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070567","date":"2014-01-23","code":"FC-1011.1/2","title":"EGRESS EXIT SIGNS VISIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070568","date":"2014-01-23","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070570","date":"2014-01-23","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070633","date":"2014-01-23","code":"FC-304.1/2","title":"EXT RUBBISH/EXCESS STORAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070632","date":"2014-01-23","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070634","date":"2014-01-23","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3408723","date":"2014-10-27","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3481013","date":"2014-12-30","code":"FC-915.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3481010","date":"2014-12-30","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3481011","date":"2014-12-30","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3481012","date":"2014-12-30","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4078463","date":"2016-07-27","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4164423","date":"2016-09-20","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2025-094425","date":"2025-12-04","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-094426","date":"2025-12-04","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"COMPLIED","resolutionDate":"2026-03-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}],"violationCases":[{"number":"201366","type":"IMMINENTLY DANGEROUS","priority":"IMMINENTLY DANGEROUS","responsibility":"CSU","status":"CLOSED","createdDate":"2009-06-03","completedDate":"2010-01-06","violations":[{"number":"1382346","date":"2009-06-03","code":"PM-308.1/11","title":"WALL PARTIALLY COLLAPSED ID","status":"COMPEXCP","resolutionDate":null,"resolution":null},{"number":"1382347","date":"2009-06-03","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPEXCP","resolutionDate":null,"resolution":null}]},{"number":"217763","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2009-10-16","completedDate":"2013-10-31","violations":[{"number":"1495901","date":"2009-10-16","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1495902","date":"2009-10-16","code":"PM-311.0/2","title":"EXT-GRAFFITI","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"372223","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-03-12","completedDate":"2013-04-19","violations":[{"number":"2736968","date":"2013-03-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2736969","date":"2013-03-11","code":"FC-901.6/12","title":"FIRE DEPT CONNECT REP DAM CAPS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"373349","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-03-21","completedDate":"2013-11-05","violations":[{"number":"2967373","date":"2013-03-20","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2967371","date":"2013-03-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2967372","date":"2013-03-20","code":"FC-405.2/2","title":"EVAC DRILL-GRP B HI RISE-2X/YR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2967374","date":"2013-03-20","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"392191","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2013-07-18","completedDate":"2013-07-22","violations":[{"number":"2867378","date":"2013-07-18","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"ERROR","resolutionDate":null,"resolution":null}]},{"number":"406094","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-10-08","completedDate":"2013-11-05","violations":[{"number":"2962534","date":"2013-10-04","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2962533","date":"2013-10-04","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"417304","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-01-27","completedDate":"2014-12-30","violations":[{"number":"3070569","date":"2014-01-23","code":"FC-605.4/1","title":"FIRE-ELECT MULTIPLUG PROHIB","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070572","date":"2014-01-23","code":"FC-607.3/1","title":"ELEVATOR KEY LOCATION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070576","date":"2014-01-23","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070575","date":"2014-01-23","code":"FC-907.20/1","title":"FA-TEST REQ","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070574","date":"2014-01-23","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070573","date":"2014-01-23","code":"FC-703.1/5","title":"FIRE-DOOR/HARDWARE MAINTAIN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070566","date":"2014-01-23","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070567","date":"2014-01-23","code":"FC-1011.1/2","title":"EGRESS EXIT SIGNS VISIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070568","date":"2014-01-23","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070570","date":"2014-01-23","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"417314","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-01-27","completedDate":"2014-12-30","violations":[{"number":"3070633","date":"2014-01-23","code":"FC-304.1/2","title":"EXT RUBBISH/EXCESS STORAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070632","date":"2014-01-23","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3070634","date":"2014-01-23","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"458495","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2014-10-27","completedDate":"2015-04-01","violations":[{"number":"3408723","date":"2014-10-27","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"464920","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-12-30","completedDate":"2015-02-26","violations":[{"number":"3481013","date":"2014-12-30","code":"FC-915.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3481010","date":"2014-12-30","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3481011","date":"2014-12-30","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3481012","date":"2014-12-30","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"547210","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2016-07-29","completedDate":"2016-10-19","violations":[{"number":"4078463","date":"2016-07-27","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"557692","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2016-09-30","completedDate":"2017-02-08","violations":[{"number":"4164423","date":"2016-09-20","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2025-130347","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2025-12-04","completedDate":null,"violations":[{"number":"VI-2025-094425","date":"2025-12-04","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-094426","date":"2025-12-04","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"COMPLIED","resolutionDate":"2026-03-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]}],"violYears":[{"y":2009,"n":4,"worst":null},{"y":2013,"n":9,"worst":null},{"y":2014,"n":18,"worst":null},{"y":2016,"n":2,"worst":null},{"y":2025,"n":2,"worst":null}],"investigations":[{"caseNumber":"64701","date":"2006-12-07","type":"BC INSP","status":"PASSED"},{"caseNumber":"201366","date":"2009-06-03","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"201366","date":"2009-06-25","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"201366","date":"2010-01-06","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"372223","date":"2013-03-11","type":"CI INSP","status":"FAILED"},{"caseNumber":"373349","date":"2013-03-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"372223","date":"2013-04-18","type":"CI INSP","status":"PASSED"},{"caseNumber":"392191","date":"2013-07-18","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"392191","date":"2013-07-22","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"373349","date":"2013-07-23","type":"CI INSP","status":"FAILED"},{"caseNumber":"406094","date":"2013-10-04","type":"CI INSP","status":"FAILED"},{"caseNumber":"373349","date":"2013-10-09","type":"CI INSP","status":"CLOSED"},{"caseNumber":"373349","date":"2013-11-05","type":"PRECOURT","status":"PASSED"},{"caseNumber":"406094","date":"2013-11-05","type":"CI INSP","status":"PASSED"},{"caseNumber":"417304","date":"2014-01-23","type":"CI INSP","status":"FAILED"},{"caseNumber":"417314","date":"2014-01-23","type":"CI INSP","status":"FAILED"},{"caseNumber":"458495","date":"2014-10-27","type":"BC INSP","status":"FAILED"},{"caseNumber":"458495","date":"2014-12-01","type":"BC INSP","status":"FAILED"},{"caseNumber":"417314","date":"2014-12-30","type":"CI INSP","status":"PASSED"},{"caseNumber":"417304","date":"2014-12-30","type":"CI INSP","status":"PASSED"},{"caseNumber":"464920","date":"2015-02-25","type":"CI INSP","status":"PASSED"},{"caseNumber":"464920","date":"2015-02-25","type":"CI INSP","status":"PASSED"},{"caseNumber":"464920","date":"2015-02-25","type":"CI INSP","status":"PASSED"},{"caseNumber":"458495","date":"2015-04-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"547210","date":"2016-07-27","type":"CI INSP","status":"FAILED"},{"caseNumber":"547210","date":"2016-09-01","type":"CI INSP","status":"FAILED"},{"caseNumber":"557692","date":"2016-09-20","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"547210","date":"2016-10-14","type":"CI INSP","status":"PASSED"},{"caseNumber":"557692","date":"2016-10-25","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"557692","date":"2016-12-01","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"557692","date":"2017-02-07","type":"PRECOURT","status":"PASSED"},{"caseNumber":"CF-2025-130347","date":"2025-12-04","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-130347","date":"2026-01-08","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-130347","date":"2026-03-13","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-130347","date":"2026-04-30","type":null,"status":"FAILED"}],"inspYears":[{"y":2006,"fails":0,"passes":1},{"y":2009,"fails":2,"passes":0},{"y":2010,"fails":0,"passes":1},{"y":2013,"fails":5,"passes":4},{"y":2014,"fails":4,"passes":2},{"y":2015,"fails":0,"passes":4},{"y":2016,"fails":4,"passes":1},{"y":2017,"fails":0,"passes":1},{"y":2025,"fails":1,"passes":0},{"y":2026,"fails":3,"passes":0}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.95009656144414,"lng":-75.16836980553482,"geom":{"type":"Polygon","coordinates":[[[-75.168316803,39.949925978],[-75.168493238,39.949949164],[-75.168423379,39.950266942],[-75.168245924,39.950243539],[-75.168316803,39.949925978]]]},"liDistrict":"CENTRAL WEST","certifications":[{"number":"BC-2022-007481","type":"Facade Report","inspectionDate":"2014-12-23","result":"Safe with Repair","expirationDate":"2019-12-23","buildingId":"1454523"},{"number":"BC-2021-006973","type":"Sprinkler Certification","inspectionDate":"2021-09-16","result":"Certified","expirationDate":"2022-09-16","buildingId":"1454523"},{"number":"BC-2022-002246","type":"Sprinkler Certification","inspectionDate":"2022-02-17","result":"Certified","expirationDate":"2023-02-17","buildingId":"1454523"},{"number":"BC-2022-018514","type":"Sprinkler Certification","inspectionDate":"2022-11-14","result":"Certified","expirationDate":"2023-11-14","buildingId":"1454523"},{"number":"BC-2022-017506","type":"Sprinkler Certification","inspectionDate":"2022-11-15","result":"Certified","expirationDate":"2023-11-15","buildingId":"1454523"},{"number":"BC-2023-025592","type":"Special Hazards Certification","inspectionDate":"2023-11-09","result":"Certified","expirationDate":"2024-11-09","buildingId":"1454523"},{"number":"BC-2024-030307","type":"Sprinkler Certification","inspectionDate":"2024-11-01","result":"Certified","expirationDate":"2025-11-01","buildingId":"1454523"},{"number":"BC-2026-001444","type":"Sprinkler Certification","inspectionDate":"2025-12-22","result":"Certified","expirationDate":"2026-12-22","buildingId":"1454523"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19103","beds":null,"baths":null,"stories":6,"lotArea":5967,"zoning":"CMX5","grade":"C","basement":null,"heater":null,"centralAir":null,"extCond":"3","intCond":"3","garage":null,"homestead":false,"mail":"3535 US HWY ONE, PRINCETON NJ, 08540","mailOut":true,"appeals":[{"type":"Building standards appeal","grounds":"ON 3/23/09 DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED NOTICE OF REFUSAL FOR APPLICATION # 201895.","status":"OPEN","outcome":"APPROVED","date":"2009-05-28","number":"8835","relatedPermit":"201895"},{"type":"Zoning board appeal","grounds":"PERMIT/ CERTIFICATE APPLICATION FOR: FOR RETAIL SALE OF COSMETICS/BEAUTY SUPPLIES, A BEAUTY SALON(MANICURE/NAIL SALON) ALL IN CELLAR FIRST AND SECOND FLOORS, FOR A REAL ESTATE OFFICE ON THE THIRD FLOOR, FOR AN ADVERTISING OFFICE ON THE THIR","status":"CLOSED","outcome":"Granted","date":"2011-10-05","number":"16167","relatedPermit":"359435"},{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF A FLAT WALL CHANGEABLE MESSAGE SIGN ACCESSORY TO AN EXISTING REAL ESTATE DEVELOPMENT OFFICE -  ON A PORTION OF THE 3RD FLOOR , ADVERTISING OFFICE - PORTION OF 3RD  FLOOR AND FOURTH FLOOR AND REAL ESTATE OFFICE ON ","status":"CLOSED","outcome":"Granted with conditions","date":"2012-01-31","number":"16655","relatedPermit":"372072"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":2,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":6995600,"taxable":5196700,"land":1193400,"improvement":5802200,"taxableLand":1193400,"taxableImprovement":4003300,"exemptLand":0,"exemptImprovement":1798900},{"y":2017,"v":6995600,"taxable":5196700,"land":1193400,"improvement":5802200,"taxableLand":1193400,"taxableImprovement":4003300,"exemptLand":0,"exemptImprovement":1798900},{"y":2018,"v":7879500,"taxable":5925147,"land":1575900,"improvement":6303600,"taxableLand":1575900,"taxableImprovement":4349247,"exemptLand":0,"exemptImprovement":1954353},{"y":2019,"v":9010600,"taxable":6496338,"land":901060,"improvement":8109540,"taxableLand":901060,"taxableImprovement":5595278,"exemptLand":0,"exemptImprovement":2514262},{"y":2020,"v":9258300,"taxable":6674921,"land":925830,"improvement":8332470,"taxableLand":925830,"taxableImprovement":5749091,"exemptLand":0,"exemptImprovement":2583379},{"y":2021,"v":9258300,"taxable":9258300,"land":925830,"improvement":8332470,"taxableLand":925830,"taxableImprovement":8332470,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":9258300,"taxable":9258300,"land":925830,"improvement":8332470,"taxableLand":925830,"taxableImprovement":8332470,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":9580200,"taxable":9580200,"land":1916040,"improvement":7664160,"taxableLand":1916040,"taxableImprovement":7664160,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":9580200,"taxable":9580200,"land":1916040,"improvement":7664160,"taxableLand":1916040,"taxableImprovement":7664160,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":8309800,"taxable":8309800,"land":1661960,"improvement":6647840,"taxableLand":1661960,"taxableImprovement":6647840,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":8309800,"taxable":8309800,"land":1661960,"improvement":6647840,"taxableLand":1661960,"taxableImprovement":6647840,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":8106000,"taxable":8106000,"land":1621200,"improvement":6484800,"taxableLand":1621200,"taxableImprovement":6484800,"exemptLand":0,"exemptImprovement":0}],"taxNow":116321,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"63662","date":"2007-04-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-12-05","scope":"INSTALL NEW 8\" UNDERGROUND CONNECTION, NEW FIRE PUMP FOR CONVERSION OF DRY TO WET STANDPIPES."},{"number":"165305","date":"2008-09-11","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2008-09-11","scope":"INSTALLATION OF SINAGE. 1 ILLUNMINATED WALL SIGN AS PER PLANS"},{"number":"176621","date":"2008-09-18","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2009-01-26","scope":"INSTALL (1)FLAT WALL SIGN OVER ENTRANCE;INSTALL (1) DIRECTORY SIGN PER PLANS."},{"number":"209119","date":"2009-04-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-11-10","scope":"CHANGE WATER METER FROM 3\" TO 1 1/2\""},{"number":"208444","date":"2009-05-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-03-15","scope":"INSTALL NEW 400AMP PANEL FROM EXISTING GENERATOR, EXTEND NORMAL POWER FROM 2ND TO 6TH FLOOR, RECONNECT EXISTING 225AMP PANEL. INSTALL NEW 200AMP XFER SWITCH AND PANEL REUSE EXISTING WIRING AS PER 2005 NEC (CC DISTRICT) INSTALL 1 NEW FIRE ALARM PANEL, 20 NEW STROBES, 75 HORN STROBES, 16 SMOKES, 21 PULL STATIONS, 10 HEAT DETECTORS AND 8 TAMPER AND FLOW SWITCHES AS PER NFPA72"},{"number":"223682","date":"2009-07-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-02-04","scope":"FOR THE INSTALLATION OF STAIRWAY PRESSURIZATION IN A FULLY SPRINKLERED BUILDING AS PER APPROVED PLANS."},{"number":"236042","date":"2009-09-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-04-18","scope":"PERMIT TO COMPLY VIOLATION, CASE #201366."},{"number":"235358","date":"2009-09-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-09","scope":"PROVIDE NEW ELECTRICAL SERVICE TO BUILDING, REMOVE EXISTING PECO, PROVIDE TRANSFORMERS AND NEW UNDERGROUND WIRE, NEW 1600AMP SWITCHBOARD AND RE FEED EXISTING SWITCHGEAR, GROUNDING AS PER 2005 NEC (CC DISTRICT)"},{"number":"253990","date":"2010-02-25","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2010-02-25","scope":"FOR THE INSTALLATION OF A LIGHT BOX AND FOR THE INFILL ON 2ND AND 6TH FLOOR (SIZE AND LOCATION AS SHOWN IN THE APPLICATION). FOR VACANT COMMERCIAL/RETAIL SPACE AS PERMITTED IN THE DISTRICT NOT FOR DWELLING PURPOSES (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) ON BASEMENT THRU 4TH FLOOR AND 6TH FLOOR AND LEGALIZATION OF THE ARCHITECTS OFFICE ON THE 5TH FLOOR."},{"number":"264158","date":"2010-03-01","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2010-06-27","scope":"INTERIOR DEMOLITION OF NON-BEARING WALLS AND CEILINGS; WORK ALSO TO INCLUDE: DEMO OF SHEETMETAL DUCTWORK AND PIPING."},{"number":"268360","date":"2010-03-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-06-04","scope":"RELOCATE (25) SPRINKLER HEADS ON 2ND FLOOR OF COMMERCIAL BUILDING DUE TO DEMOLITION."},{"number":"263934","date":"2010-03-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-12-01","scope":"STRUCTURAL WORK AND REMEDIATION ONLY. INTERIOR/EXTERIOR, REMOVAL OF EXISTING SOUTHERN FACADE AND INSTALLATION OF NEW FACADE AS PER DRAWINGS, STRUCTURAL MODIFICATIONS TO CREATE ATRIUM IN EXISTING 2ND FLOOR AREA, FLOOR IN FILL ON THE SIXTH FLOOR AND NEW WINDOW FENESTRATIONS ON THE WEST AND NORTH FACADES. ***CONTRACTOR TBD*** SEPARATE SIDEWALK SHELTER PLATFORM PERMIT REQUIRED. VACANT SPACE: TENANT FIT OUTS/ALTERATIONS REQUIRED AND CO CHECK FOR PROPOSED TENANT SPACES FOR EXISTING BUILDING WITH COMMERCIAL APPROVED USES. HIGH RISE PROVISIONS WILL APPLY WHEN OCCUPIED FLOOR >75' ABOVE FD ACCESS."},{"number":"268354","date":"2010-03-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-06-04","scope":"INSTALLATION OF NEW SPRINKLERS, PIPING, RECONFIGURATION FOR INTERIOR DEMO/ALTERATIONS OF 5TH FLOOR VACANT COMMERICAL SPACE, CONNECT TO EXISTING SYSTEM/PUMP/BACKFLOW ASSEMBLY"},{"number":"271251","date":"2010-04-08","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2010-04-08","scope":"ADMINISTRATIVE OFFICES FOR A MARKETING COMPANY."},{"number":"269621","date":"2010-04-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"INTERIOR ALTERATIONS AS PER PLAN."},{"number":"271776","date":"2010-04-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-06-27","scope":"RELOCATE 24 EXISTING SPRINKLER HEADS (4TH FLOOR)"},{"number":"272543","date":"2010-04-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-06-27","scope":"ONE SINK"},{"number":"279167","date":"2010-05-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"DEMO, PROVIDE TEMP LIGHT @ THE ABOVE PROJECT AS PER 2008 NEC (CC DISTRICT)"},{"number":"272656","date":"2010-05-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-08-25","scope":"4TH FLOOR INSTALL 9 FLOOR BOXES, 1 CEILING RECPT, 3 QUADS, 2 DEDICATED RECPTS, 25 DUPLEX RECPTS, 65 LIGHTS, 6 EXIT, 8 SW, 6 DIMMERS, 15 MOTION, RELOCATE 3 FIRE ALARM DEVICES."},{"number":"280687","date":"2010-05-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-08-19","scope":"ADD 3 F/A DEVICES, REOLOCATE 3 F/A DEVICES AS PER NFPA 72 (CC DISTRICT)"},{"number":"280343","date":"2010-05-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"INSTALL NEW HANDICAP ACCESSIBLE BATHROOM ON THE THIRD FLOOR AND ALTERATIONS TO EXISTING BATHROOMS ON THE THIRD AND FOURTH FLOORS AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING."},{"number":"281926","date":"2010-05-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"RELOCATE 6 SPRINKLER HEADS (3RD & 4TH FLOOR BATHROOMS)"},{"number":"282393","date":"2010-06-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"INSTALLATION OF NEW ADA RESTROOM- ONE WATER CLOSET AND ONE LAVATORY SINK (BLDG PERMIT # 280343)"},{"number":"282704","date":"2010-06-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"RELOCATION OF (19) DIFFUSERS"},{"number":"282998","date":"2010-06-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-06-27","scope":"RELOCATE 86 SPRINKLER HEADS(BASEMENT & 2ND FLOOR)"},{"number":"281809","date":"2010-06-03","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"TO INSTALL (2) NEW OVERFLOW DRAINS ON ROOF (GOING INTO EXISTING ROOF RISER PIPE). REPLACE EXISTING ROOF DRAIN THAT GOES INTO EXISTING PIPING"},{"number":"284201","date":"2010-06-09","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"RELOCATE 6 OPENINGS"},{"number":"276361","date":"2010-06-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-08-03","scope":"FURNISH & INSTALL (248) CATEGORY 6 PLENUM CABLES, LONGEST RUN 175' AS PER 2008 NEC (NORTH DISTRICT)"},{"number":"284466","date":"2010-06-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-07-07","scope":"INSTALLATION OF FIXTURES ONLY. ROUGH-IN COMPLETED BY OTHERS: (7)WATER CLOSETS, (2)URINALS, (7)LAVATORIES"},{"number":"285172","date":"2010-07-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"EXTEND EXISTING AND INSTALL (30) NEW HEADS TO 1ST, 5TH AND 6TH FLRS."},{"number":"297076","date":"2010-09-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-12-07","scope":"PROVIDE ELECTRICAL MODIFICATIONS INCLUDING LIGHTING DEVICES AND POWE TO BASE BOARD HEATER PER DRAWINGS INSSTALLATIO PER NEC 2008CODE"},{"number":"304448","date":"2010-10-04","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2010-11-08","scope":"DEMO OF NON BEARING PARTITIONS"},{"number":"305695","date":"2010-10-20","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"PERMIT IS FOR THE INSTALLATION OF NON COMBUSTIBLE PARTITIONS, SOFFITS, AND CEILINGS ON THE THIRD FLOOR OF AN EXISTING B USE SPACE. SEPARATE PERMITS REQUIRED FOR PLUMBING, ELECTRICAL, MECHANICAL, AND FIRE SUPPRESSION WORK."},{"number":"304433","date":"2010-10-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"TENANT FIT TO CREATE IMPROVED OFFICE SPACE"},{"number":"309046","date":"2010-10-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"RELOCATE (20) DIFFUSERS FOR OFFICE BLDG."},{"number":"309414","date":"2010-11-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"RELOCATE 8 SPRINKLERS HEADS."},{"number":"304438","date":"2010-11-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"TENANT FIT OUT IN AN OFFICE"},{"number":"307932","date":"2010-11-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"REMOVE AND REINSTALL FIXTURES IN SAME LOCATIONS: (7)WATER CLOSETS, (2)URINALS, (9)LAVATORIES.."},{"number":"310084","date":"2010-11-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-20","scope":"REMOVE AND RELOCATE,15 EXISTING PENDANT FIXTURES AND 12 DUPLEX RECEPTACLES.RE-USE ALL EXISTING CIRCUITING,NO NEW CIRCUITRY REQUIRED AS PER 2008 NEC"},{"number":"309970","date":"2010-11-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-06-28","scope":"FURNISH AND INSTALL (6) CAT 5E PLENUM CABLES...LONGEST RUN- 50 FEET..... IN ACCORDANCE WITH 2008 NEC"},{"number":"309481","date":"2010-11-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-02-08","scope":"RELOCATE (85) SPRINKLERS FOR OFFICE BLDG.5TH AND 6TH FLOORS"},{"number":"309137","date":"2010-12-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-01-21","scope":"78 2X4 FIXTURES,2 2X2 FIXTURES,8 EXIT SIGNS,1 PENDANT,120 DUPLEX RECEPTACLES,29 SINGLE POLE SWITCHES AS PER 2008 NEC"},{"number":"312252","date":"2010-12-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-01-12","scope":"FURNISH & INSTALL (92) CAT5E PLENUM CABLES ON 5TH FLOOR, (133) CATE5E PLENUM CABLES ON 6TH FLOOR, LONGEST RUN 125' AS PER 2008 NEC (CC DIST)"},{"number":"330211","date":"2011-03-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-05-31","scope":"INTERIOR ALTERATIONS PER PLAN PARTIAL 3RD FLOOR TO INCLUDE SPIRAL STAIR TO 4TH FLOOR FOR NEIMAN GROUP OFFICES"},{"number":"331788","date":"2011-03-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-06-28","scope":"REMOVE AND RELOCATE 26 RECEPTACLES AND 15 EXISTING LIGHT FIXTURES,REUSE ALL EXISTING CIRCUITY,NO NEW CIRCUITING REQUIRED AS PER 2008 NEC"},{"number":"334141","date":"2011-04-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-05-31","scope":"RELOCATE (12) DIFFUSERS IN EXISTING DUCTWORK"},{"number":"334780","date":"2011-04-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-05-31","scope":"RELOCATE 22 EXISTING SPRINKLER HEADS (3RD FLOOR)"},{"number":"333253","date":"2011-04-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-06-28","scope":"FURNISH AND INSTALL APPROXIMATELY (70) CATEGORY 6 PLENUM CABLES AS PER 2008 NEC"},{"number":"359435","date":"2011-10-11","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2011-10-11","scope":"USE C,1 & 2 FOR RETAIL SALES OF COSMETICS AND BEAUTY SUPPLIES, 3RD FLOOR REAL ESTATE OFFICE; ADVERTISING OFFICE AND 4-05TH FLOOR REAL ESTATE OFFICE."},{"number":"365265","date":"2011-12-05","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2012-08-29","scope":"PRELIMINARY PLAN REVIEW"},{"number":"372072","date":"2012-02-09","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2012-02-09","scope":"ZONING FOR A LCD SIGN"},{"number":"420624","date":"2012-08-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-05-03","scope":"ALTERATION TO CREATE AN IMPROVED MULTI STORY RETAIL TENANT SPACE"},{"number":"424975","date":"2012-08-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-05-03","scope":"RELOCATE 102 SPRINKLER HEADS, BASEMENT"},{"number":"427367","date":"2012-10-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-05-03","scope":"INSTALLATION OF DUCTWORK, MECHANICALS, REGISTERS/DIFFUSERS IN MULTI-STORY TENANT SPACE."},{"number":"427086","date":"2012-10-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-05-29","scope":"NEW SANITARY & WATER LINES CONNECTED TO EXISTING SERVICES IN BLDG, NEW FIXTURES-4 TOILETS, 4 LAV SINKS, 7 SINKS, 3 FLOOR DRAINS, 1 MOP RECEPTOR & 1 WATER COOLER (RETAIL TENANT SPACES)"},{"number":"433883","date":"2012-12-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-05-03","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM AT THE 2ND LEVEL OF AN EXISTING STRUCTURE IN CONFORMANCE WITH NFPA 2007, STANDARD 13."},{"number":"442360","date":"2013-01-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL VOICE AND DATA WIRING 74 COMMUNICATION OUTLET IN ACCORDANCE WITH 2008 NEC(WEST DIST). INSTALLATION TO COMPLY WITH ARTICLES 300.21 & 800 OF THE 2008 NEC."},{"number":"436401","date":"2013-02-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-30","scope":"INSTALL NEW LIGHTING, NEW/RELOCATED FIRE ALARM DEVICES, NEW RECEPTACLES & SWITCHES, NEW EMS PANEL AND NEW PANEL BOARD E AS PER 2008 NEC & NFPA 72 (OFFICES)"},{"number":"456070","date":"2013-03-01","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2013-03-04","scope":"T C O IN ASSOCIATION WITH ALTERATIONS PERMIT #420624"},{"number":"451372","date":"2013-03-14","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2013-03-14","scope":"FOR USE OF THE 3RD FLOOR BREAKROOM. TENANT ONLY"},{"number":"462025","date":"2013-04-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-06-26","scope":"INSTALL LOW VOLTAGE WIRING FOR CHECK POINT SECURITY SYSTEM, CONNECT CONTROL PANEL TO 5 SECURITY STATIONS AS PER NEC 2008 (COMM)"},{"number":"450845","date":"2013-04-02","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2013-04-02","scope":"INSTALLATION OF ONE ILLUMINATED CHANNEL LETTER SIGN TO READ ULTRA BEAUTY"},{"number":"462014","date":"2013-04-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-08-27","scope":"INTERIOR DEMO AND RENOVATIONS FOR EXISTING OFFICE SPACES, UPGRADES TO FINISHES, NEW INTERIOR PARTITIONS, WINDOWS AND DOORS FOR OUTDOOR 3RD FLOOR AREA, RE-USE AND RELOCATE EXISTING FIXTURES, NEW FURNISHINGS. NO CHANGE IN USE OR OCCUPANCY CLASSIFICATION. CO REQUESTED AND ATTACHED AS MATTER OF RECORD. ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS, SIGNS, IF ANY MODIFIED/NEW"},{"number":"459323","date":"2013-04-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-07","scope":"FURNISH & INSTALL 56-CATEGORY, 6-PLENUM CABLES FOR VOICE & DATA. INSTALLATION TO COMPLY WITH ARTICLES 300.21 & 800 OF THE 2008 NEC."},{"number":"462511","date":"2013-04-11","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2013-05-13","scope":"INSTALL ONE INTERNALLY ILLUMINATED CHANNEL LETTER WALL SIGN ATTACHED PER SEALED ENGINEER'S PLAN. SEPARATE ELECTRIC PERMIT REQUIRED."},{"number":"471227","date":"2013-05-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-11-26","scope":"RELOCATE 8 EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE WALL AND/OR CEILING LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"471228","date":"2013-05-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-07-18","scope":"RELOCATE 20 EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW TENANT WALL AND CEILING LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"471550","date":"2013-05-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-07-18","scope":"RELOCATE 25 CEILINGS DIFFUSERS TO ACCOMMODATE NEW TENANT LAYOUT ON THIRD FLOOR."},{"number":"475479","date":"2013-06-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-07-18","scope":"RELOCATE (6) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE WALL AND CEILING LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES (LOBBY)"},{"number":"480463","date":"2013-06-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-10-03","scope":"RELOCATE WIRING FOR NEW GFI'S IN EXISTING BATHROOMS RELOCATE LIGHTING THROUGHOUT AND SINGLE POLE SWITCHING/MOTION SENSORS FOR NEW LAYOUT PER 2008 NEC (COMMERCIAL)"},{"number":"505532","date":"2013-12-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL LIGHTING AND OCCUPANCY SENSORS,WIRING DEVICES AND FURNITURE FEEDS PER 2008 NEC (OFFICE SPACE)"},{"number":"545376","date":"2014-07-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"INTERIOR ALTERATIONS ON THE 6TH FLOOR EXISTING OFFICE SPACE TO INCLUDE NEW INTERIOR NON-LOAD BEARING PARTITIONS AND ALL OTHER ALTERATIONS AS PER APPROVED PLANS."},{"number":"580011","date":"2014-12-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-01-14","scope":"SIDEWALK SHELTER PLATFORM AS PER ATTACHED PLANS."},{"number":"598857","date":"2015-03-27","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-09-15","scope":"RELOCATE 7 SPRINKLERS FOR AN ELEVATOR MODERNIZATION ON THE 6TH FLOOR AND PENTHOUSE EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"600139","date":"2015-05-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-08-25","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING ELEVATOR MACHINE ROOM IN AN EXISTING HIGH RISE BUILDING AS PER APPROVED PLANS."},{"number":"601478","date":"2015-05-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-08-25","scope":"INSTALL (2) DUCTLESS MINI SPLITS AS PER PLANS."},{"number":"613552","date":"2015-07-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-14","scope":"FURNISH & INSTALL ALL NECESSARY POWER & LIGHTING AS PER NEC 2008 & FURNISH & INSTALL STROBES, SMOKES & HEAT DETECTORS WHERE REQUIRED AS PER NFPA 72 (OFFICE SPACE)CC DISTRICT"},{"number":"643154","date":"2015-10-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-01-20","scope":"SIDEWALK SHELTER SHED PLATFORM SCAFFOLD"},{"number":"906151","date":"2018-08-29","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-05-15","scope":"ERECTION OF A SIDEWALK SHELTER PLATFORM AS PER ENGINEERED PLANS. STREETS DEPARTMENT PERMIT IS REQUIRED FOR SIDEWALK CLOSURE PRIOR TO THE START WORK."},{"number":"907397","date":"2018-09-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2020-11-23","scope":"REPOINTING BRICK FACADES, REPLACEMENT OF DAMAGED BRICK, REPLACEMENT OF SEALANT, AND CLEANING AND RECOATING EXPOSED STEEL SURFACES AS PER APPROVED PLANS. PEDESTRIAN PROTECTION REQUIRED AS PER B-3306."},{"number":"GM-2020-007376","date":"2020-09-14","work":"Roof Covering Replacement","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2021-10-05","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2021-007633","date":"2021-11-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-03-06","scope":"FOR LEVEL II ALTERATIONS TO INCLUDE PARTITIONS, FIXTURES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK."},{"number":"MP-2021-007241","date":"2021-12-30","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2023-03-21","scope":"Mechanical / Fuel Gas Permit for combo CP-2021-007633"},{"number":"PP-2021-020472","date":"2022-01-05","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2023-03-24","scope":"Plumbing Permit (Interior) for combo CP-2021-007633"},{"number":"EP-2021-012810","date":"2022-01-06","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-03-23","scope":"Electrical Permit for combo CP-2021-007633"},{"number":"FP-2022-000378","date":"2022-02-09","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2023-03-06","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (3) Sprinkler Heads on the 3rd floor and (9) Sprinkler Heads on the 4th floor offices. (CP-2021-007633)"},{"number":"EP-2022-008746","date":"2023-04-17","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-07-21","scope":"INSTALL A 300 KW GENERATOR, 800 AMP FEEDER FROM THE GENERATOR TO THE TROUGH, INSTALL A 200 AMP FEEDER TO THE EXISTING 200 AMP FUSED DISCONNECT SWITCH, INSTALL A 400 AMP FEEDER TO THE EXISTING 400 AMP FUSED DISCONNECT SWITCH. INSTALL A 200 AMP FEEDER FROM THE GENERATOR TO THE EXISTING FIRE PUMP TRANSFER SWITCH, INSTALL A 200 AMP SERVICE TO THE NEW 200 AMP FIRE PUMP SERVICE DISCONNECT SWITCH. ALL WORK IN ACCORDANCE WITH THE 2017 NEC."},{"number":"MP-2024-001043","date":"2024-03-14","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-09-20","scope":"FOR THE INSTALLATION OF APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. *NO REGISTERS, DIFFUSERS ON THIS PERMIT."},{"number":"EP-2024-003190","date":"2024-04-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-24","scope":"• Demo/make safe electrical connections to existing AHU-1 • Supply and install (1) 200amp fusible disconnect for connection to new unit single point connection; re-terminate circuit. • Mount new field installed VFD to BC-1 in replacement of the existing motor starter reconnect the existing feeder. * Equipment is replacement in kind using existing feeders."},{"number":"CP-2024-002693","date":"2024-05-16","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-10-21","scope":"FOR A LEVEL II INTERIOR AND EXTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"FP-2024-001103","date":"2024-05-28","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-06-16","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (30) SPRINKLER HEADS AS PER NFPA 13 AND LOCAL CODE"},{"number":"PP-2024-007604","date":"2024-06-12","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-09-20","scope":"INSTALL THREE INCH SANITARY PIPING AND CAP FOR FUTERE WORK. INSTALL THREE INCH VENT PIPING AND CAP FOR FUTURE WORK AND INSTALL 3/4 INCH DOMESTIC WATER SUPPLY PIPING WITH SHUT OFF VALVE FOR FUTURE WORK ACCORDING TO THE 2018 PPC AND PER PLANS."},{"number":"EP-2024-006116","date":"2024-07-17","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-17","scope":"Furnish and install Fire Alarm as per drawings Furnish and install 4 duplex outlets, 16 A fixtures, 5 EM, 2 RH and 3 exits, 4 ceiling occupancy sensors. Relocate three panels, add metering per panel-2017 NEC.2016 NFPA-72."},{"number":"CP-2024-003591","date":"2024-08-22","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-01-16","scope":"For level iI alteration without change of occupancy classification to include interior tenant fit-out improvement with new partitions, new light fixtures, new merchandising displays, a new ADA complaint room, new storefront roll and a security gate as per approved plans. Building is fully sprinklered. Separate permits required for MEP & FP work. Amendment to the special inspection items."},{"number":"PP-2024-011617","date":"2024-08-29","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-01-16","scope":"Plumbing Permit (Interior) for combo CP-2024-003591"},{"number":"MP-2024-003847","date":"2024-08-29","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-01-16","scope":"Mechanical / Fuel Gas Permit for combo CP-2024-003591"},{"number":"EP-2024-008188","date":"2024-09-03","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-01-08","scope":"AMEND PERMIT 12/23/2024 PER OWNERS REPRESENTATIVE REQUEST. Electrical Permit for combo CP-2024-003591"},{"number":"FP-2024-001871","date":"2024-09-05","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-01-16","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (30) SPRINKLER HEADS AS PER NFPA 13"},{"number":"EP-2024-009448","date":"2024-09-30","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-01-08","scope":"Provide CAT6 Telecom cabling for (24) Tele/Data Outlets. Raceways By Others."},{"number":"EP-2024-009525","date":"2024-10-04","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-01-10","scope":"Install a security system control panel and various security alarm devices. Install (7) CCTV cameras. All wiring to be fished through existing ceiling spaces. **Low voltage wiring only. No electrical."},{"number":"EP-2024-009159","date":"2024-10-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-12-17","scope":"Install Fire Alarm as per drawings and 2016 NFPA 72."},{"number":"ZP-2024-012323","date":"2024-12-12","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Retail Sales - Wearing Apparel and Accessories"},{"number":"ZP-2024-008692","date":"2024-12-23","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"FOR ERECTION OF ONE (1) ILLUMINATED FLAT WALL SIGN ON CANOPY OF EXISTING STRUCTURE . SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLAN."},{"number":"GP-2024-011265","date":"2025-02-05","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2025-02-27","scope":"FOR THE INSTALLATION OF ONE (1) ILLUMINATED FLAT WALL SIGN ON THE CANOPY OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK."}],"storyTag":"Improved","storyDelta":-0.26,"timeline":[{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Addition and/or Alterations"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Addition and/or Alteration"},{"y":2024,"k":"permit","w":"Change of Use"},{"y":2024,"k":"permit","w":"Signs (Accessory / Non-Accessory)"},{"y":2025,"k":"permit","w":"Sign"},{"y":2025,"k":"viol","w":"2 L&I violations"},{"y":2025,"k":"insp","w":"Inspection failed"},{"y":2026,"k":"sale","p":5230000},{"y":2026,"k":"insp","w":"Inspection failed ×3"}],"rented":false,"licenses":[{"number":"299181","type":"High Rise","status":"Closed","businessName":"GIRARD ESTATE","legalName":"GIRARD ESTATE","address":"1619-21 WALNUT ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2004-04-08","latestIssueDate":"2007-05-01","expirationDate":"2008-04-30","inactiveDate":"2012-07-24"},{"number":"294266","type":"Dumpster License - Public ROW","status":"Closed","businessName":"PHILADELPHIA BISTRO INC","legalName":"PHILADELPHIA BISTRO INC","address":"1619-21 WALNUT ST","revenueCode":"3417","rentalCategory":null,"units":null,"issuedDate":"2004-04-08","latestIssueDate":"2008-04-03","expirationDate":"2009-03-31","inactiveDate":"2011-12-14"},{"number":"294267","type":"Dumpster License - Public ROW","status":"Closed","businessName":"PHILADELPHIA BISTRO INC","legalName":"PHILADELPHIA BISTRO INC","address":"1619-21 WALNUT ST","revenueCode":"3417","rentalCategory":null,"units":null,"issuedDate":"2004-04-08","latestIssueDate":"2008-04-03","expirationDate":"2009-03-31","inactiveDate":"2011-12-14"},{"number":"209119","type":"Food Preparing and Serving (30+ SEATS)","status":"Closed","businessName":"PHILADELPHIA BISTRO LTD INC","legalName":"PHILADELPHIA BISTRO LTD INC","address":"1619-21 WALNUT ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2004-04-08","latestIssueDate":"2008-04-29","expirationDate":"2009-04-30","inactiveDate":"2012-12-22"},{"number":"294268","type":"Dumpster License - Public ROW","status":"Inactive","businessName":"PHILADELPHIA BISTRO INC","legalName":"PHILADELPHIA BISTRO INC","address":"1619-21 WALNUT ST","revenueCode":"3417","rentalCategory":null,"units":null,"issuedDate":"2004-04-17","latestIssueDate":"2008-04-03","expirationDate":"2009-03-31","inactiveDate":"2011-12-14"},{"number":"210011","type":"Sidewalk Cafe","status":"Closed","businessName":"PHILADELPHIA BISTRO LTD INC","legalName":"PHILADELPHIA BISTRO LTD INC","address":"1619-21 WALNUT ST","revenueCode":"3123","rentalCategory":null,"units":null,"issuedDate":"2004-06-27","latestIssueDate":"2004-06-27","expirationDate":"2005-06-30","inactiveDate":null},{"number":"318777","type":"Sidewalk Cafe","status":"Closed","businessName":"PHILADELPHIA BISTRO LTD INC","legalName":"PHILADELPHIA BISTRO LTD INC","address":"1619-21 WALNUT ST","revenueCode":"3123","rentalCategory":null,"units":null,"issuedDate":"2005-05-17","latestIssueDate":"2008-07-03","expirationDate":"2009-06-30","inactiveDate":"2009-05-15"},{"number":"535211","type":"Dumpster License - Private Property","status":"Closed","businessName":"WALNUT STREET RETAIL INVESTORS LP","legalName":"WALNUT STREET RETAIL INVESTORS LP","address":"1619-21 WALNUT ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2011-06-06","latestIssueDate":"2011-06-06","expirationDate":"2012-07-31","inactiveDate":null},{"number":"566404","type":"High Rise","status":"Inactive","businessName":"WALNUT STREET RETAIL INVESTORS LP","legalName":"WALNUT STREET RETAIL INVESTORS LP","address":"1619-21 WALNUT ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2012-06-08","latestIssueDate":"2025-12-31","expirationDate":"2026-04-30","inactiveDate":"2026-06-29"},{"number":"594054","type":"Dumpster License - Private Property","status":"Active","businessName":"ULTA SALON COSMETICS & FRAGRANCE INC","legalName":"ULTA SALON COSMETICS & FRAGRANCE INC","address":"1619-21 WALNUT ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2013-05-17","latestIssueDate":"2013-08-03","expirationDate":null,"inactiveDate":null},{"number":"597802","type":"Dumpster License - Public ROW","status":"Closed","businessName":"ULTA SALON COSMETICS & FRAGRANCE INC","legalName":"ULTA SALON COSMETICS & FRAGRANCE INC","address":"1619-21 WALNUT ST","revenueCode":"3417","rentalCategory":null,"units":null,"issuedDate":"2013-06-28","latestIssueDate":"2020-05-13","expirationDate":"2021-03-31","inactiveDate":null},{"number":"794438","type":"Dumpster License - Public ROW","status":"Active","businessName":"WALNUT STREET RETAIL INVESTORS LP","legalName":"WALNUT STREET RETAIL INVESTORS LP","address":"1619-21 WALNUT ST","revenueCode":"3417","rentalCategory":null,"units":null,"issuedDate":"2018-11-14","latestIssueDate":"2025-12-15","expirationDate":"2026-11-13","inactiveDate":null}],"licenseActivity":[{"number":"794438","type":"Dumpster License - Public ROW","businessName":"WALNUT STREET RETAIL INVESTORS LP","legalName":"WALNUT STREET RETAIL INVESTORS LP","issuedDate":"2018-11-14","latestIssueDate":"2025-12-15","closureDate":null,"expirationDate":"2026-11-13","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"597802","type":"Dumpster License - Public ROW","businessName":"ULTA SALON COSMETICS & FRAGRANCE INC","legalName":"ULTA SALON COSMETICS & FRAGRANCE INC","issuedDate":"2013-06-28","latestIssueDate":"2020-05-13","closureDate":"2021-03-31","expirationDate":"2021-03-31","inactiveDate":null,"status":"Closed","statusLabel":"Closed","active":false},{"number":"594054","type":"Dumpster License - Private Property","businessName":"ULTA SALON COSMETICS & FRAGRANCE INC","legalName":"ULTA SALON COSMETICS & FRAGRANCE INC","issuedDate":"2013-05-17","latestIssueDate":"2013-08-03","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"566404","type":"High Rise","businessName":"WALNUT STREET RETAIL INVESTORS LP","legalName":"WALNUT STREET RETAIL INVESTORS LP","issuedDate":"2012-06-08","latestIssueDate":"2025-12-31","closureDate":"2026-06-29","expirationDate":"2026-04-30","inactiveDate":"2026-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"535211","type":"Dumpster License - Private Property","businessName":"WALNUT STREET RETAIL INVESTORS LP","legalName":"WALNUT STREET RETAIL INVESTORS LP","issuedDate":"2011-06-06","latestIssueDate":"2011-06-06","closureDate":"2012-07-31","expirationDate":"2012-07-31","inactiveDate":null,"status":"Closed","statusLabel":"Closed","active":false},{"number":"318777","type":"Sidewalk Cafe","businessName":"PHILADELPHIA BISTRO LTD INC","legalName":"PHILADELPHIA BISTRO LTD INC","issuedDate":"2004-06-27","latestIssueDate":"2008-07-03","closureDate":"2009-05-15","expirationDate":"2009-06-30","inactiveDate":"2009-05-15","status":"Closed","statusLabel":"Inactive","active":false},{"number":"294266","type":"Dumpster License - Public ROW","businessName":"PHILADELPHIA BISTRO INC","legalName":"PHILADELPHIA BISTRO INC","issuedDate":"2004-04-08","latestIssueDate":"2008-04-03","closureDate":"2011-12-14","expirationDate":"2009-03-31","inactiveDate":"2011-12-14","status":"Closed","statusLabel":"Inactive","active":false},{"number":"209119","type":"Food Preparing and Serving (30+ SEATS)","businessName":"PHILADELPHIA BISTRO LTD INC","legalName":"PHILADELPHIA BISTRO LTD INC","issuedDate":"2004-04-08","latestIssueDate":"2008-04-29","closureDate":"2012-12-22","expirationDate":"2009-04-30","inactiveDate":"2012-12-22","status":"Closed","statusLabel":"Inactive","active":false},{"number":"299181","type":"High Rise","businessName":"GIRARD ESTATE","legalName":"GIRARD ESTATE","issuedDate":"2004-04-08","latestIssueDate":"2007-05-01","closureDate":"2012-07-24","expirationDate":"2008-04-30","inactiveDate":"2012-07-24","status":"Closed","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"record-pressure","level":"elevated","title":"Records to verify together","summary":"More than one separately dated public record deserves a current-status check.","evidence":["2 open L&I violations","failed L&I inspection activity in 2025, 2026"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #165305: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"7 permits not marked completed: 545376 (EXPIRED), 907397 (Expired), GM-2020-007376 (Expired), CP-2021-007633 (Expired), MP-2021-007241 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"2 open L&I violations","finding":"35 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"building-certifications","level":"attention","title":"A life-safety certification appears expired","finding":"Facade Report: Safe with Repair through Dec 23, 2019; Sprinkler Certification: Certified through Dec 22, 2026; Special Hazards Certification: Certified through Nov 9, 2024","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"19 failed, 14 passed, and 2 CLOSED investigation outcomes are in the fetched history; the latest dated visit was FAILED on Apr 30, 2026.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"High Rise #299181: Closed since Jul 24, 2012; Dumpster License - Public ROW #294266: Closed since Dec 14, 2011; Dumpster License - Public ROW #294267: Closed since Dec 14, 2011; Food Preparing and Serving (30+ SEATS) #209119: Closed since Dec 22, 2012","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}