{"asOf":"2026-07-27T03:51:47.221Z","block":"1500-1599 MARKET ST","blockUrl":"https://philadelphia.blockreport.homes/block/1500-1599-market-st","address":"1500-42 MARKET ST","parcelNumber":"883320000","source":"https://property.phila.gov/?p=883320000","ownerType":"investor","kind":"offices","isHouse":false,"home":false,"commercial":true,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"DA0","buildingCodeNew":"243","buildingClass":"OFF BLD W/COM GAR MASONRY","buildingClassNew":"OFFICE BLDNG - High Rise","useLabel":"Offices","owner":"NG 1500 MARKET ST LLC","coOwner":null,"marketValue":107000000,"landAssessment":21974800,"improvementAssessment":85025200,"livableArea":2215276,"yearBuilt":1974,"lastSale":{"price":328000000,"date":"2017-07-14T04:00:00Z"},"openViolations":36,"violations":[{"number":"539994","date":"2007-04-11","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"535589","date":"2007-04-03","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"535597","date":"2007-04-04","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"535603","date":"2007-04-04","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"535609","date":"2007-04-04","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"535624","date":"2007-04-03","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"538618","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"538804","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"538847","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"538864","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"538890","date":"2007-04-05","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"538896","date":"2007-04-05","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"539980","date":"2007-04-11","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"540005","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"540006","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"540007","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"541557","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1741697","date":"2007-04-11","code":"06-301.2/11","title":"FREEZER DESSERT MIX LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1741698","date":"2007-04-11","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1741690","date":"2007-04-11","code":"LR-1","title":"RENEW LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"545416","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"545429","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"545470","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"545667","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"545670","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"546650","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"546701","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"546747","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"546791","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"546840","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"547119","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"547134","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"548329","date":"2007-04-19","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1176643","date":"2007-04-19","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"548336","date":"2007-04-19","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"548357","date":"2007-04-19","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"548368","date":"2007-04-19","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550076","date":"2007-04-20","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550080","date":"2007-04-20","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550102","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550119","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550144","date":"2007-04-20","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550582","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550604","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550697","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"550718","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"552835","date":"2007-04-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"552837","date":"2007-04-23","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"552847","date":"2007-04-23","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"552858","date":"2007-04-23","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"552873","date":"2007-04-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"552884","date":"2007-04-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"553276","date":"2007-04-24","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554390","date":"2007-04-24","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1899073","date":"2007-04-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554399","date":"2007-04-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554416","date":"2007-04-25","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554422","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554423","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554547","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554557","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554560","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"554575","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"556136","date":"2007-04-26","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559271","date":"2007-04-26","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1898849","date":"2007-04-26","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559284","date":"2007-04-26","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559287","date":"2007-04-26","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559293","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559294","date":"2007-04-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559462","date":"2007-04-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559523","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"559537","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1899057","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"560360","date":"2007-05-01","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1898876","date":"2007-05-01","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1899088","date":"2007-05-01","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"560413","date":"2007-05-01","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"560417","date":"2007-05-02","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"561302","date":"2007-05-03","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1149917","date":"2007-05-03","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"561307","date":"2007-05-03","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1899058","date":"2007-05-02","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"561315","date":"2007-05-02","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"561318","date":"2007-05-02","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1898892","date":"2007-05-03","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"710269","date":"2007-10-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"991553","date":"2008-06-17","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"991554","date":"2008-06-17","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1176632","date":"2008-12-01","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"1176751","date":"2008-12-01","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"1591407","date":"2010-02-10","code":"PM-307.1/18","title":"RETAINING/FENCE WALL PRTLY C","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1797715","date":"2010-08-24","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1797716","date":"2010-08-24","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1797717","date":"2010-08-24","code":"FC-904.11/4","title":"AFES-COMM KITCH SERVICE & CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1797714","date":"2010-08-24","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1813106","date":"2010-08-31","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1813109","date":"2010-08-31","code":"FC-1011.1/2","title":"EGRESS EXIT SIGNS VISIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1813108","date":"2010-08-31","code":"FC-903.6/1","title":"SPRINKLER HEADS CLEARANCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1813107","date":"2010-08-31","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2272877","date":"2011-10-27","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2698395","date":"2013-01-24","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2698382","date":"2013-01-24","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2698383","date":"2013-01-24","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2698384","date":"2013-01-24","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2960941","date":"2013-10-07","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116504","date":"2014-03-19","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116488","date":"2014-03-19","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116489","date":"2014-03-19","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116490","date":"2014-03-19","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116491","date":"2014-03-19","code":"FC-2703.5/2","title":"HAZMAT ID ABOVEGROUND TANKS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116492","date":"2014-03-19","code":"FC-2703.5/5","title":"HAZMAT-INDIV CARTON ETC LABEL","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116493","date":"2014-03-19","code":"FC-2703.9/6","title":"HAZMAT-SEPARATE INCOMPAT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116494","date":"2014-03-19","code":"FC-2705.2/1","title":"HAZMAT-INDOOR DISPENSE & USE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116495","date":"2014-03-19","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116500","date":"2014-03-19","code":"FC-901.6/13","title":"FIRE SUPP DRY CHEM SYS MAINT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116505","date":"2014-03-19","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116506","date":"2014-03-19","code":"PM-407.2/1","title":"ELEC-FAC MEET ELEC CODE-RES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116507","date":"2014-03-20","code":"PM-407.2/2","title":"ELEC-SYSTEM HAZARDOUS-RES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116336","date":"2014-03-19","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116335","date":"2014-03-19","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116334","date":"2014-03-19","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116337","date":"2014-03-19","code":"FC-1027.2/1","title":"EGRESS CLEAR OBSTRUCTION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116339","date":"2014-03-19","code":"FC-607.2/1","title":"ELEVATORS POST EMERGENCY SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116338","date":"2014-03-19","code":"FC-2703.5/2","title":"HAZMAT ID ABOVEGROUND TANKS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116342","date":"2014-03-19","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116341","date":"2014-03-19","code":"FC-901.4/1","title":"OBTAIN PERMIT EXTEN SPRKLR SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116340","date":"2014-03-19","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3154842","date":"2014-03-20","code":"FC-1004.3/1","title":"EGRESS-ASSEM OCC SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3154841","date":"2014-03-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451463","date":"2015-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451464","date":"2015-01-20","code":"FC-13-605.6","title":"OPEN JUNCTION BOXES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451465","date":"2015-01-20","code":"FC-13-703","title":"FIRE RESISTANCE RATING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451470","date":"2015-01-20","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451471","date":"2015-01-20","code":"FC-13-912","title":"GENERAL REQ.- CITE CODE SECTIO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451492","date":"2015-01-20","code":"FC-13-1006","title":null,"status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451491","date":"2015-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451493","date":"2015-01-20","code":"FC-13-703","title":"FIRE RESISTANCE RATING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451496","date":"2015-01-20","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3808371","date":"2015-11-17","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3808370","date":"2015-11-17","code":"A-301.1/43","title":"PERMB- INSTALL DUCTWORK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4002655","date":"2016-07-08","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141706","date":"2016-11-09","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141711","date":"2016-11-09","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141710","date":"2016-11-09","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141709","date":"2016-11-09","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141708","date":"2016-11-09","code":"FC-1011.1/2","title":"EGRESS EXIT SIGNS VISIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141707","date":"2016-11-09","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4143243","date":"2016-11-10","code":"A-301.1/32","title":"PERME- EXTEND SMKE DETECT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4236727","date":"2017-02-27","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"ERROR","resolutionDate":null,"resolution":null},{"number":"4236726","date":"2017-02-27","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4882184","date":"2018-11-26","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4918502","date":"2019-01-07","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4918503","date":"2019-01-07","code":"FC-13-906.3","title":"SIZE AND DISTRIBUTION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"211992416","date":"2020-02-26","code":"FC-13-1003.4","title":"EGRESS READILY OPENABLE","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992415","date":"2020-02-26","code":"LR-1","title":"RENEW LIC INDICATED","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992414","date":"2020-02-26","code":"FC-13-906.5","title":"EXTINGUISHER - CONSPICUOUS LOC","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992378","date":"2020-02-26","code":"FC-13-915.1A","title":"FIRE SUPPRESSION CERTIFICATION","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992377","date":"2020-02-26","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992376","date":"2020-02-26","code":"FC-13-100823","title":"LOCKING DEVICES","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011383","date":"2021-03-03","code":"FC-13-101","title":"ADMINISTRATION GENERAL","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011384","date":"2021-03-03","code":"FC-13-604.1","title":"EMERGENCY LIGHTING TESTED","status":"COMPLIED","resolutionDate":"2021-06-03","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011391","date":"2021-03-03","code":"FC-13-701","title":"FIRE RESISTANCE RATED CONSTRUCTION","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011392","date":"2021-03-03","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011393","date":"2021-03-03","code":"FC-13-907.5.1","title":"PULL STATION SIGNS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011394","date":"2021-03-03","code":"PM15-604.3","title":"ELECTRICAL- HAZARD","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011395","date":"2021-03-03","code":"FC-13-2703.5","title":"NFPA 704 SIGNS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011396","date":"2021-03-03","code":"FC-13-901","title":"FIRE PROTECTION SYSTEMS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011397","date":"2021-03-03","code":"FC-13-807","title":"VIOLATION OF DECORATIVE MATERIALS REQUIREMENTS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011398","date":"2021-03-03","code":"FC-13-915.1(B)","title":"STANDPIPE SYSTEM CERTIFICATION","status":"COMPLIED","resolutionDate":"2021-06-03","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011399","date":"2021-03-03","code":"FC-13-1016.1","title":"MEANS OF EGRESS MAINTENANCE","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011385","date":"2021-03-03","code":"FC-13-906","title":"PORTABLE FIRE EXTINGUISHERS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-075362","date":"2021-10-26","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":"2021-12-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2021-075363","date":"2021-10-26","code":"A-402.4","title":"FAILURE TO PERFORM SPECIAL INSPECTIONS","status":"COMPLIED","resolutionDate":"2021-12-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2021-087797","date":"2021-12-21","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":"2022-01-31","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2021-087798","date":"2021-12-21","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":"2022-01-31","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2022-054543","date":"2022-07-27","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"CLOSED","resolutionDate":"2024-02-29","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2022-054536","date":"2022-07-27","code":"A-301.1/66","title":"PERMZ- OR REMOVE ADVERTISING","status":"COMPLIED","resolutionDate":"2023-07-27","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-054540","date":"2022-07-27","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2022-10-12","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2023-053340","date":"2023-07-20","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-013661","date":"2024-02-29","code":"F-912.4.1","title":"FDC LOCKING CAPS\n","status":"CLOSED","resolutionDate":"2024-03-26","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2024-013664","date":"2024-02-29","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-03-26","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-013654","date":"2024-02-29","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"CLOSED","resolutionDate":"2024-03-26","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2024-013665","date":"2024-02-29","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-03-26","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-020224","date":"2024-03-26","code":"F-701.2","title":"FIRE RESISTANCE RATED CONSTRUCTION\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020003","date":"2024-03-26","code":"F-906.1","title":"FIRE EXTINGUISHERS REQUIRED\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020009","date":"2024-03-26","code":"F-5003.5.1","title":"MARKING OF CONTAINERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020015","date":"2024-03-26","code":"F-5303.5.3","title":"SECURING COMPRESSED CYLINDERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020019","date":"2024-03-26","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020022","date":"2024-03-26","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020182","date":"2024-03-26","code":"F-316.2.2","title":"INTERIOR ACCESS TO SHAFTWAYS","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-020183","date":"2024-03-26","code":"F-1031.4","title":"EXIT SIGNS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020184","date":"2024-03-26","code":"F-1013.6.2","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020189","date":"2024-03-26","code":"F-906.7","title":"FIRE EXTINGUISHER HANGERS & BRACKETS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020198","date":"2024-03-26","code":"F-1031.2","title":"RELIABILITY\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020199","date":"2024-03-26","code":"F-315.3","title":"STORAGE IN BUILDINGS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020202","date":"2024-03-26","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020205","date":"2024-03-26","code":"F-604.5 ","title":"EXTENSION CORDS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020213","date":"2024-03-26","code":"F-604.6","title":"UNAPPROVED CONDITIONS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020220","date":"2024-03-26","code":"F-315.3.3","title":"EQUIPMENT ROOMS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020221","date":"2024-03-26","code":"F-315.3.1","title":"CEILING CLEARANCE\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020348","date":"2024-03-26","code":"F-1013.1","title":"EXIT SIGNS WHERE REQUIRED\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020356","date":"2024-03-26","code":"F-912.4.1","title":"FDC LOCKING CAPS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020399","date":"2024-03-26","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2026-05-08","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-020400","date":"2024-03-26","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2026-05-08","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-019890","date":"2024-03-26","code":"F-701.6.1.5","title":"DAMPER CERTIFICATION REPORT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-019891","date":"2024-03-26","code":"F-909.20.2","title":"SMOKE CONTROL SYSTEM RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-019893","date":"2024-03-26","code":"F-403.11.2","title":"HIGH RISE BUILDINGS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-019894","date":"2024-03-26","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"COMPLIED","resolutionDate":"2026-03-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-019897","date":"2024-03-26","code":"F-1203.4.3","title":"RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-019924","date":"2024-03-26","code":"F-904.8","title":"CARBON DIOXIDE SYSTEMS\n","status":"COMPLIED","resolutionDate":"2026-03-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-019998","date":"2024-03-26","code":"F-5004.2.1","title":"SPILL CONTROL\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020407","date":"2024-03-26","code":"F-906.1","title":"FIRE EXTINGUISHERS REQUIRED\n","status":"COMPLIED","resolutionDate":"2024-05-01","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020423","date":"2024-03-26","code":"F-906.7","title":"FIRE EXTINGUISHER HANGERS & BRACKETS\n","status":"COMPLIED","resolutionDate":"2025-02-04","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020424","date":"2024-03-26","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"COMPLIED","resolutionDate":"2025-02-04","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020422","date":"2024-03-26","code":"LR-1","title":"FOOD PREPARING AND SERVING","status":"COMPLIED","resolutionDate":"2025-02-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-020419","date":"2024-03-26","code":"LO-1","title":"SCALES AND SCANNERS","status":"COMPLIED","resolutionDate":"2025-02-04","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-020474","date":"2024-03-26","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020473","date":"2024-03-26","code":"F-906.6","title":"FIRE EXTINGUISHER UNOBSTRUCTED & UNOBSCURED\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2026-016850","date":"2026-03-24","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"3179705","date":"2014-05-15","code":"A-402.5/2","title":"PERMB- FINAL PRE-CO INSP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3510082","date":"2015-04-01","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3510083","date":"2015-04-01","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3801905","date":"2015-12-17","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3801906","date":"2015-12-17","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"4680048","date":"2018-05-17","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4882150","date":"2018-11-26","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"98439","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-01-18","completedDate":"2008-12-03","violations":[{"number":"539994","date":"2007-04-11","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"107752","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-04","completedDate":"2007-04-04","violations":[{"number":"535589","date":"2007-04-03","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"107758","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-04","completedDate":"2007-04-04","violations":[{"number":"535597","date":"2007-04-04","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"107760","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-04","completedDate":"2007-04-04","violations":[{"number":"535603","date":"2007-04-04","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"107765","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-04","completedDate":"2007-04-04","violations":[{"number":"535609","date":"2007-04-04","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"107769","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-04","completedDate":"2007-04-04","violations":[{"number":"535624","date":"2007-04-03","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108143","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-10","completedDate":"2007-04-10","violations":[{"number":"538618","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108179","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-10","completedDate":"2007-04-10","violations":[{"number":"538804","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108188","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-10","completedDate":"2007-04-10","violations":[{"number":"538847","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108192","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-10","completedDate":"2007-04-10","violations":[{"number":"538864","date":"2007-04-10","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108195","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-10","completedDate":"2007-04-10","violations":[{"number":"538890","date":"2007-04-05","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108197","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-10","completedDate":"2007-04-10","violations":[{"number":"538896","date":"2007-04-05","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108339","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-11","completedDate":"2007-04-17","violations":[{"number":"539980","date":"2007-04-11","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108345","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-11","completedDate":"2007-04-11","violations":[{"number":"540005","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108346","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-11","completedDate":"2007-04-11","violations":[{"number":"540006","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108347","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-11","completedDate":"2007-04-11","violations":[{"number":"540007","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108516","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-12","completedDate":"2007-04-12","violations":[{"number":"541557","date":"2007-04-11","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108518","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-12","completedDate":"2010-07-08","violations":[{"number":"1741697","date":"2007-04-11","code":"06-301.2/11","title":"FREEZER DESSERT MIX LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1741698","date":"2007-04-11","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"108923","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-16","completedDate":"2010-07-08","violations":[{"number":"1741690","date":"2007-04-11","code":"LR-1","title":"RENEW LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109158","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-17","completedDate":"2007-04-17","violations":[{"number":"545416","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109163","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-17","completedDate":"2007-04-17","violations":[{"number":"545429","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109170","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-17","completedDate":"2007-04-17","violations":[{"number":"545470","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109198","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-17","completedDate":"2007-04-17","violations":[{"number":"545667","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109200","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-17","completedDate":"2007-04-17","violations":[{"number":"545670","date":"2007-04-17","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109377","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-18","completedDate":"2007-04-18","violations":[{"number":"546650","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109379","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-18","completedDate":"2007-04-18","violations":[{"number":"546701","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109380","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-18","completedDate":"2007-04-18","violations":[{"number":"546747","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109381","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-18","completedDate":"2007-04-18","violations":[{"number":"546791","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109383","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-18","completedDate":"2007-04-18","violations":[{"number":"546840","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109427","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-18","completedDate":"2007-04-18","violations":[{"number":"547119","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109430","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-18","completedDate":"2007-04-18","violations":[{"number":"547134","date":"2007-04-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109543","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-19","completedDate":"2007-04-19","violations":[{"number":"548329","date":"2007-04-19","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109545","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-19","completedDate":"2008-12-22","violations":[{"number":"1176643","date":"2007-04-19","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109547","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-19","completedDate":"2007-04-26","violations":[{"number":"548336","date":"2007-04-19","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109552","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-19","completedDate":"2007-04-19","violations":[{"number":"548357","date":"2007-04-19","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109554","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-19","completedDate":"2007-04-26","violations":[{"number":"548368","date":"2007-04-19","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109755","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-20","completedDate":"2007-04-20","violations":[{"number":"550076","date":"2007-04-20","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109758","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-20","completedDate":"2007-04-20","violations":[{"number":"550080","date":"2007-04-20","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109761","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-20","completedDate":"2017-07-11","violations":[{"number":"550102","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109764","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-20","completedDate":"2008-12-03","violations":[{"number":"550119","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109768","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-20","completedDate":"2007-04-20","violations":[{"number":"550144","date":"2007-04-20","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109838","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-23","completedDate":"2007-05-03","violations":[{"number":"550582","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109841","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-23","completedDate":"2007-05-24","violations":[{"number":"550604","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109853","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-23","completedDate":"2008-11-19","violations":[{"number":"550697","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"109855","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-23","completedDate":"2008-10-30","violations":[{"number":"550718","date":"2007-04-20","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110161","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-24","completedDate":"2007-04-24","violations":[{"number":"552835","date":"2007-04-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110162","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-24","completedDate":"2007-04-25","violations":[{"number":"552837","date":"2007-04-23","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110164","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-24","completedDate":"2008-12-03","violations":[{"number":"552847","date":"2007-04-23","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110166","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-24","completedDate":"2008-12-02","violations":[{"number":"552858","date":"2007-04-23","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110167","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-24","completedDate":"2007-04-24","violations":[{"number":"552873","date":"2007-04-23","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110168","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-24","completedDate":"2007-08-13","violations":[{"number":"552884","date":"2007-04-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110253","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-24","completedDate":"2007-04-24","violations":[{"number":"553276","date":"2007-04-24","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110357","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2007-04-25","violations":[{"number":"554390","date":"2007-04-24","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110358","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2016-07-20","violations":[{"number":"1899073","date":"2007-04-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110359","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2008-06-04","violations":[{"number":"554399","date":"2007-04-24","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110360","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2008-12-03","violations":[{"number":"554416","date":"2007-04-25","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110364","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2007-04-25","violations":[{"number":"554422","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110365","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2007-04-25","violations":[{"number":"554423","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110399","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2007-04-25","violations":[{"number":"554547","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110402","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2007-04-25","violations":[{"number":"554557","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110405","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2007-04-25","violations":[{"number":"554560","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110406","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-25","completedDate":"2007-04-25","violations":[{"number":"554575","date":"2007-04-25","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"110617","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-04-26","completedDate":"2007-04-26","violations":[{"number":"556136","date":"2007-04-26","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111014","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2007-05-01","violations":[{"number":"559271","date":"2007-04-26","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111019","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2011-01-05","violations":[{"number":"1898849","date":"2007-04-26","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111020","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2007-05-01","violations":[{"number":"559284","date":"2007-04-26","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111021","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2008-12-02","violations":[{"number":"559287","date":"2007-04-26","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111023","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2008-12-03","violations":[{"number":"559293","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111024","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2017-07-11","violations":[{"number":"559294","date":"2007-04-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111057","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2007-05-01","violations":[{"number":"559462","date":"2007-04-27","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111059","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2008-12-03","violations":[{"number":"559523","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111062","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2008-11-05","violations":[{"number":"559537","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111065","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-01","completedDate":"2017-07-17","violations":[{"number":"1899057","date":"2007-04-27","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111144","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-02","completedDate":"2008-11-19","violations":[{"number":"560360","date":"2007-05-01","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111146","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-02","completedDate":"2011-01-05","violations":[{"number":"1898876","date":"2007-05-01","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111150","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-02","completedDate":"2016-07-20","violations":[{"number":"1899088","date":"2007-05-01","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111153","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-02","completedDate":"2007-05-02","violations":[{"number":"560413","date":"2007-05-01","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111154","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-02","completedDate":"2007-05-24","violations":[{"number":"560417","date":"2007-05-02","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111313","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-03","completedDate":"2008-12-03","violations":[{"number":"561302","date":"2007-05-03","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111314","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-03","completedDate":"2010-07-30","violations":[{"number":"1149917","date":"2007-05-03","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111316","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-03","completedDate":"2007-05-03","violations":[{"number":"561307","date":"2007-05-03","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111319","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-03","completedDate":"2016-07-20","violations":[{"number":"1899058","date":"2007-05-02","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111321","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-03","completedDate":"2008-12-02","violations":[{"number":"561315","date":"2007-05-02","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111322","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-03","completedDate":"2007-05-03","violations":[{"number":"561318","date":"2007-05-02","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"111717","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-05-07","completedDate":"2015-12-11","violations":[{"number":"1898892","date":"2007-05-03","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"131891","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2007-10-22","completedDate":"2007-10-22","violations":[{"number":"710269","date":"2007-10-18","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"165799","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2008-06-19","completedDate":"2008-10-06","violations":[{"number":"991553","date":"2008-06-17","code":"19-2602.1/1","title":"CAL LO","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"991554","date":"2008-06-17","code":"LO-1","title":"OBTAIN LIC INDICATED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"186923","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2008-12-03","completedDate":"2008-12-03","violations":[{"number":"1176632","date":"2008-12-01","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"186940","type":"STANDARD","priority":"STANDARD","responsibility":"BU","status":"CLOSED","createdDate":"2008-12-03","completedDate":"2008-12-03","violations":[{"number":"1176751","date":"2008-12-01","code":"A-000.0/11","title":"VIOL BC MESSAGE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"226757","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2010-02-11","completedDate":"2010-03-04","violations":[{"number":"1591407","date":"2010-02-10","code":"PM-307.1/18","title":"RETAINING/FENCE WALL PRTLY C","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"248758","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2010-08-25","completedDate":"2010-10-08","violations":[{"number":"1797715","date":"2010-08-24","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1797716","date":"2010-08-24","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1797717","date":"2010-08-24","code":"FC-904.11/4","title":"AFES-COMM KITCH SERVICE & CERT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1797714","date":"2010-08-24","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"249856","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2010-09-01","completedDate":"2010-10-08","violations":[{"number":"1813106","date":"2010-08-31","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1813109","date":"2010-08-31","code":"FC-1011.1/2","title":"EGRESS EXIT SIGNS VISIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1813108","date":"2010-08-31","code":"FC-903.6/1","title":"SPRINKLER HEADS CLEARANCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1813107","date":"2010-08-31","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"305411","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-11-08","completedDate":"2011-11-08","violations":[{"number":"2272877","date":"2011-10-27","code":"A-000.0/1","title":"VIOL NONE FOUND","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"366991","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-01-25","completedDate":"2013-03-07","violations":[{"number":"2698395","date":"2013-01-24","code":"FC-915.1/3","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2698382","date":"2013-01-24","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2698383","date":"2013-01-24","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2698384","date":"2013-01-24","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"405869","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2013-10-07","completedDate":"2013-12-13","violations":[{"number":"2960941","date":"2013-10-07","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"422782","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-03-19","completedDate":"2014-04-23","violations":[{"number":"3116504","date":"2014-03-19","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116488","date":"2014-03-19","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116489","date":"2014-03-19","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116490","date":"2014-03-19","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116491","date":"2014-03-19","code":"FC-2703.5/2","title":"HAZMAT ID ABOVEGROUND TANKS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116492","date":"2014-03-19","code":"FC-2703.5/5","title":"HAZMAT-INDIV CARTON ETC LABEL","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116493","date":"2014-03-19","code":"FC-2703.9/6","title":"HAZMAT-SEPARATE INCOMPAT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116494","date":"2014-03-19","code":"FC-2705.2/1","title":"HAZMAT-INDOOR DISPENSE & USE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116495","date":"2014-03-19","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116500","date":"2014-03-19","code":"FC-901.6/13","title":"FIRE SUPP DRY CHEM SYS MAINT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116505","date":"2014-03-19","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116506","date":"2014-03-19","code":"PM-407.2/1","title":"ELEC-FAC MEET ELEC CODE-RES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116507","date":"2014-03-20","code":"PM-407.2/2","title":"ELEC-SYSTEM HAZARDOUS-RES","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"422788","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-03-19","completedDate":"2014-04-23","violations":[{"number":"3116336","date":"2014-03-19","code":"FC-1019.1/2","title":"EGRESS LANDING SIGN IN STAIRS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116335","date":"2014-03-19","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116334","date":"2014-03-19","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116337","date":"2014-03-19","code":"FC-1027.2/1","title":"EGRESS CLEAR OBSTRUCTION","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116339","date":"2014-03-19","code":"FC-607.2/1","title":"ELEVATORS POST EMERGENCY SIGN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116338","date":"2014-03-19","code":"FC-2703.5/2","title":"HAZMAT ID ABOVEGROUND TANKS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116342","date":"2014-03-19","code":"FC-907.4/4","title":"FIRE-PULL STATION SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116341","date":"2014-03-19","code":"FC-901.4/1","title":"OBTAIN PERMIT EXTEN SPRKLR SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3116340","date":"2014-03-19","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"422821","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2014-03-20","completedDate":"2014-05-08","violations":[{"number":"3154842","date":"2014-03-20","code":"FC-1004.3/1","title":"EGRESS-ASSEM OCC SIGNS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3154841","date":"2014-03-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"466479","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2015-01-20","completedDate":"2015-03-18","violations":[{"number":"3451463","date":"2015-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451464","date":"2015-01-20","code":"FC-13-605.6","title":"OPEN JUNCTION BOXES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451465","date":"2015-01-20","code":"FC-13-703","title":"FIRE RESISTANCE RATING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451470","date":"2015-01-20","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451471","date":"2015-01-20","code":"FC-13-912","title":"GENERAL REQ.- CITE CODE SECTIO","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"466481","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2015-01-20","completedDate":"2015-03-18","violations":[{"number":"3451492","date":"2015-01-20","code":"FC-13-1006","title":null,"status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451491","date":"2015-01-20","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451493","date":"2015-01-20","code":"FC-13-703","title":"FIRE RESISTANCE RATING","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3451496","date":"2015-01-20","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"510767","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2015-11-18","completedDate":"2016-02-05","violations":[{"number":"3808371","date":"2015-11-17","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3808370","date":"2015-11-17","code":"A-301.1/43","title":"PERMB- INSTALL DUCTWORK","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"543375","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2016-07-08","completedDate":"2016-08-15","violations":[{"number":"4002655","date":"2016-07-08","code":"A-301.1/55","title":"PERMP- ALTER/REPAIR/REPL PLUMB","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"563151","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2016-11-09","completedDate":"2016-12-14","violations":[{"number":"4141706","date":"2016-11-09","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141711","date":"2016-11-09","code":"FC-906.2/2","title":"FIRE EXTING-NEEDS INSP/TAG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141710","date":"2016-11-09","code":"FC-703.1/2","title":"FIRE-MAINTAIN FIREBLOCK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141709","date":"2016-11-09","code":"FC-605.6/1","title":"FIRE-ELECT OPEN JUNCTION BOX","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141708","date":"2016-11-09","code":"FC-1011.1/2","title":"EGRESS EXIT SIGNS VISIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4141707","date":"2016-11-09","code":"FC-1006.3/2","title":"EMERG LIGHTING DEFECTIVE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"563308","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2016-11-10","completedDate":"2016-12-19","violations":[{"number":"4143243","date":"2016-11-10","code":"A-301.1/32","title":"PERME- EXTEND SMKE DETECT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"574140","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2017-02-28","completedDate":"2017-03-17","violations":[{"number":"4236727","date":"2017-02-27","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"ERROR","resolutionDate":null,"resolution":null},{"number":"4236726","date":"2017-02-27","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"664922","type":"CONSTRUCTION SERVICES","priority":"CONSTRUCTION SERVICES","responsibility":"DCC","status":"CLOSED","createdDate":"2018-11-26","completedDate":"2018-12-17","violations":[{"number":"4882184","date":"2018-11-26","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"669593","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2019-01-08","completedDate":"2019-03-15","violations":[{"number":"4918502","date":"2019-01-07","code":"FC-13-906.2","title":"FIRE EXTINGUISHERS TAGGED","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"4918503","date":"2019-01-07","code":"FC-13-906.3","title":"SIZE AND DISTRIBUTION","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"725409","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PROPERTY MAINTENANCE INVESTIGATOR","status":"CLOSED","createdDate":"2020-02-27","completedDate":"2021-06-08","violations":[{"number":"211992416","date":"2020-02-26","code":"FC-13-1003.4","title":"EGRESS READILY OPENABLE","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992415","date":"2020-02-26","code":"LR-1","title":"RENEW LIC INDICATED","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992414","date":"2020-02-26","code":"FC-13-906.5","title":"EXTINGUISHER - CONSPICUOUS LOC","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992378","date":"2020-02-26","code":"FC-13-915.1A","title":"FIRE SUPPRESSION CERTIFICATION","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992377","date":"2020-02-26","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"},{"number":"211992376","date":"2020-02-26","code":"FC-13-100823","title":"LOCKING DEVICES","status":"COMPLIED","resolutionDate":"2020-10-08","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2021-014647","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2021-03-03","completedDate":"2021-06-03","violations":[{"number":"VI-2021-011383","date":"2021-03-03","code":"FC-13-101","title":"ADMINISTRATION GENERAL","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011384","date":"2021-03-03","code":"FC-13-604.1","title":"EMERGENCY LIGHTING TESTED","status":"COMPLIED","resolutionDate":"2021-06-03","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011391","date":"2021-03-03","code":"FC-13-701","title":"FIRE RESISTANCE RATED CONSTRUCTION","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011392","date":"2021-03-03","code":"FC-13-901.6","title":"FIRE SYSTEMS MAINTAINED","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011393","date":"2021-03-03","code":"FC-13-907.5.1","title":"PULL STATION SIGNS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011394","date":"2021-03-03","code":"PM15-604.3","title":"ELECTRICAL- HAZARD","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011395","date":"2021-03-03","code":"FC-13-2703.5","title":"NFPA 704 SIGNS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011396","date":"2021-03-03","code":"FC-13-901","title":"FIRE PROTECTION SYSTEMS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011397","date":"2021-03-03","code":"FC-13-807","title":"VIOLATION OF DECORATIVE MATERIALS REQUIREMENTS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011398","date":"2021-03-03","code":"FC-13-915.1(B)","title":"STANDPIPE SYSTEM CERTIFICATION","status":"COMPLIED","resolutionDate":"2021-06-03","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011399","date":"2021-03-03","code":"FC-13-1016.1","title":"MEANS OF EGRESS MAINTENANCE","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2021-011385","date":"2021-03-03","code":"FC-13-906","title":"PORTABLE FIRE EXTINGUISHERS","status":"COMPLIED","resolutionDate":"2021-04-23","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2021-104621","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"BUILDING INVESTIGATOR","status":"CLOSED","createdDate":"2021-10-26","completedDate":"2021-12-10","violations":[{"number":"VI-2021-075362","date":"2021-10-26","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":"2021-12-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2021-075363","date":"2021-10-26","code":"A-402.4","title":"FAILURE TO PERFORM SPECIAL INSPECTIONS","status":"COMPLIED","resolutionDate":"2021-12-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2021-120003","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"BUILDING INVESTIGATOR","status":"CLOSED","createdDate":"2021-12-21","completedDate":"2022-01-31","violations":[{"number":"VI-2021-087797","date":"2021-12-21","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":"2022-01-31","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2021-087798","date":"2021-12-21","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":"2022-01-31","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2022-074883","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2022-07-27","completedDate":"2024-03-04","violations":[{"number":"VI-2022-054543","date":"2022-07-27","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"CLOSED","resolutionDate":"2024-02-29","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2022-054536","date":"2022-07-27","code":"A-301.1/66","title":"PERMZ- OR REMOVE ADVERTISING","status":"COMPLIED","resolutionDate":"2023-07-27","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-054540","date":"2022-07-27","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2022-10-12","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2023-070321","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"BUILDING INVESTIGATOR","status":"IN VIOLATION","createdDate":"2023-07-20","completedDate":null,"violations":[{"number":"VI-2023-053340","date":"2023-07-20","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"CF-2024-016565","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2024-03-04","completedDate":"2024-03-26","violations":[{"number":"VI-2024-013661","date":"2024-02-29","code":"F-912.4.1","title":"FDC LOCKING CAPS\n","status":"CLOSED","resolutionDate":"2024-03-26","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2024-013664","date":"2024-02-29","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-03-26","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-013654","date":"2024-02-29","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"CLOSED","resolutionDate":"2024-03-26","resolution":"CLOSED - REISSUED/REWRITTEN"},{"number":"VI-2024-013665","date":"2024-02-29","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-03-26","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2024-024430","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2024-03-26","completedDate":null,"violations":[{"number":"VI-2024-020224","date":"2024-03-26","code":"F-701.2","title":"FIRE RESISTANCE RATED CONSTRUCTION\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020003","date":"2024-03-26","code":"F-906.1","title":"FIRE EXTINGUISHERS REQUIRED\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020009","date":"2024-03-26","code":"F-5003.5.1","title":"MARKING OF CONTAINERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020015","date":"2024-03-26","code":"F-5303.5.3","title":"SECURING COMPRESSED CYLINDERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020019","date":"2024-03-26","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020022","date":"2024-03-26","code":"F-509.1.1","title":"UTILITY IDENTIFICATION\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020182","date":"2024-03-26","code":"F-316.2.2","title":"INTERIOR ACCESS TO SHAFTWAYS","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-020183","date":"2024-03-26","code":"F-1031.4","title":"EXIT SIGNS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020184","date":"2024-03-26","code":"F-1013.6.2","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020189","date":"2024-03-26","code":"F-906.7","title":"FIRE EXTINGUISHER HANGERS & BRACKETS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020198","date":"2024-03-26","code":"F-1031.2","title":"RELIABILITY\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020199","date":"2024-03-26","code":"F-315.3","title":"STORAGE IN BUILDINGS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020202","date":"2024-03-26","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020205","date":"2024-03-26","code":"F-604.5 ","title":"EXTENSION CORDS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020213","date":"2024-03-26","code":"F-604.6","title":"UNAPPROVED CONDITIONS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020220","date":"2024-03-26","code":"F-315.3.3","title":"EQUIPMENT ROOMS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020221","date":"2024-03-26","code":"F-315.3.1","title":"CEILING CLEARANCE\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020348","date":"2024-03-26","code":"F-1013.1","title":"EXIT SIGNS WHERE REQUIRED\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020356","date":"2024-03-26","code":"F-912.4.1","title":"FDC LOCKING CAPS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020399","date":"2024-03-26","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2026-05-08","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-020400","date":"2024-03-26","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2026-05-08","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-019890","date":"2024-03-26","code":"F-701.6.1.5","title":"DAMPER CERTIFICATION REPORT\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-019891","date":"2024-03-26","code":"F-909.20.2","title":"SMOKE CONTROL SYSTEM RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-019893","date":"2024-03-26","code":"F-403.11.2","title":"HIGH RISE BUILDINGS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-019894","date":"2024-03-26","code":"F-105.6.3","title":"HIGH-RISE BUILDING\n","status":"COMPLIED","resolutionDate":"2026-03-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-019897","date":"2024-03-26","code":"F-1203.4.3","title":"RECORDS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2024-019924","date":"2024-03-26","code":"F-904.8","title":"CARBON DIOXIDE SYSTEMS\n","status":"COMPLIED","resolutionDate":"2026-03-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-019998","date":"2024-03-26","code":"F-5004.2.1","title":"SPILL CONTROL\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2024-024950","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2024-03-27","completedDate":"2024-05-02","violations":[{"number":"VI-2024-020407","date":"2024-03-26","code":"F-906.1","title":"FIRE EXTINGUISHERS REQUIRED\n","status":"COMPLIED","resolutionDate":"2024-05-01","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2024-024956","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2024-03-27","completedDate":null,"violations":[{"number":"VI-2024-020423","date":"2024-03-26","code":"F-906.7","title":"FIRE EXTINGUISHER HANGERS & BRACKETS\n","status":"COMPLIED","resolutionDate":"2025-02-04","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020424","date":"2024-03-26","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"COMPLIED","resolutionDate":"2025-02-04","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020422","date":"2024-03-26","code":"LR-1","title":"FOOD PREPARING AND SERVING","status":"COMPLIED","resolutionDate":"2025-02-27","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-020419","date":"2024-03-26","code":"LO-1","title":"SCALES AND SCANNERS","status":"COMPLIED","resolutionDate":"2025-02-04","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2024-025024","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2024-03-27","completedDate":null,"violations":[{"number":"VI-2024-020474","date":"2024-03-26","code":"F-906.2","title":"FIRE EXTINGUISHERS\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-020473","date":"2024-03-26","code":"F-906.6","title":"FIRE EXTINGUISHER UNOBSTRUCTED & UNOBSCURED\n","status":"COMPLIED","resolutionDate":"2026-03-24","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2026-027258","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"QOL FIRE SAFETY INVESTIGATOR","status":"IN VIOLATION","createdDate":"2026-03-24","completedDate":null,"violations":[{"number":"VI-2026-016850","date":"2026-03-24","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"456618","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3179705","date":"2014-05-15","code":"A-402.5/2","title":"PERMB- FINAL PRE-CO INSP","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"595376","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3510082","date":"2015-04-01","code":"A-301.1/4","title":"PERMB- ALTER REPAIR INT PART","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3510083","date":"2015-04-01","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"638717","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"3801905","date":"2015-12-17","code":"A-301.1/51","title":"PERME- INST/REPL/REPAIR WIRE","status":"CLOSEDCASE","resolutionDate":null,"resolution":null},{"number":"3801906","date":"2015-12-17","code":"A-302.8/32","title":"INSURANCE - POST CERT","status":"CLOSEDCASE","resolutionDate":null,"resolution":null}]},{"number":"866839","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"4680048","date":"2018-05-17","code":"A-402.1/1","title":"COMPL CONCEAL- BLDG PERM WORK","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"904169","type":null,"priority":null,"responsibility":null,"status":"CLOSED","createdDate":null,"completedDate":null,"violations":[{"number":"4882150","date":"2018-11-26","code":"A-302.11/1","title":"PERMB- WK DONE W/O NOTIFY INSP","status":"COMPLIED","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2007,"n":87,"worst":null},{"y":2008,"n":4,"worst":null},{"y":2010,"n":9,"worst":null},{"y":2011,"n":1,"worst":null},{"y":2013,"n":5,"worst":null},{"y":2014,"n":25,"worst":null},{"y":2015,"n":15,"worst":null},{"y":2016,"n":8,"worst":null},{"y":2017,"n":2,"worst":null},{"y":2018,"n":3,"worst":null},{"y":2019,"n":2,"worst":null},{"y":2020,"n":6,"worst":null},{"y":2021,"n":16,"worst":null},{"y":2022,"n":3,"worst":null},{"y":2023,"n":1,"worst":null},{"y":2024,"n":39,"worst":null},{"y":2026,"n":1,"worst":null}],"investigations":[{"caseNumber":"57753","date":"2006-03-03","type":"CI INSP","status":"FAILED"},{"caseNumber":"54764","date":"2006-03-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"57753","date":"2006-06-06","type":"CI INSP","status":"PASSED"},{"caseNumber":"71975","date":"2006-07-24","type":"BC INSP","status":"PASSED"},{"caseNumber":"71976","date":"2006-07-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"71978","date":"2006-07-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"72235","date":"2006-07-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"72241","date":"2006-07-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"107752","date":"2007-04-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"107769","date":"2007-04-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"107758","date":"2007-04-04","type":"BC INSP","status":"PASSED"},{"caseNumber":"107760","date":"2007-04-04","type":"BC INSP","status":"PASSED"},{"caseNumber":"107765","date":"2007-04-04","type":"BC INSP","status":"PASSED"},{"caseNumber":"108195","date":"2007-04-05","type":"BC INSP","status":"PASSED"},{"caseNumber":"108197","date":"2007-04-05","type":"BC INSP","status":"PASSED"},{"caseNumber":"108143","date":"2007-04-10","type":"BC INSP","status":"PASSED"},{"caseNumber":"108179","date":"2007-04-10","type":"BC INSP","status":"PASSED"},{"caseNumber":"108188","date":"2007-04-10","type":"BC INSP","status":"PASSED"},{"caseNumber":"108192","date":"2007-04-10","type":"BC INSP","status":"PASSED"},{"caseNumber":"108339","date":"2007-04-11","type":"BC INSP","status":"FAILED"},{"caseNumber":"108345","date":"2007-04-11","type":"BC INSP","status":"PASSED"},{"caseNumber":"108346","date":"2007-04-11","type":"BC INSP","status":"PASSED"},{"caseNumber":"108347","date":"2007-04-11","type":"BC INSP","status":"PASSED"},{"caseNumber":"108347","date":"2007-04-11","type":"BC INSP","status":"PASSED"},{"caseNumber":"108516","date":"2007-04-11","type":"BC INSP","status":"PASSED"},{"caseNumber":"108518","date":"2007-04-11","type":"BC INSP","status":"FAILED"},{"caseNumber":"108923","date":"2007-04-11","type":"BC INSP","status":"FAILED"},{"caseNumber":"108339","date":"2007-04-17","type":"BC INSP","status":"PASSED"},{"caseNumber":"109158","date":"2007-04-17","type":"BC INSP","status":"PASSED"},{"caseNumber":"109163","date":"2007-04-17","type":"BC INSP","status":"PASSED"},{"caseNumber":"109170","date":"2007-04-17","type":"BC INSP","status":"PASSED"},{"caseNumber":"109198","date":"2007-04-17","type":"BC INSP","status":"PASSED"},{"caseNumber":"109200","date":"2007-04-17","type":"BC INSP","status":"PASSED"},{"caseNumber":"109377","date":"2007-04-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"109379","date":"2007-04-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"109380","date":"2007-04-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"109381","date":"2007-04-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"109383","date":"2007-04-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"109427","date":"2007-04-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"109430","date":"2007-04-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"109543","date":"2007-04-19","type":"BC INSP","status":"PASSED"},{"caseNumber":"109545","date":"2007-04-19","type":"BC INSP","status":"FAILED"},{"caseNumber":"109547","date":"2007-04-19","type":"BC INSP","status":"FAILED"},{"caseNumber":"109552","date":"2007-04-19","type":"BC INSP","status":"PASSED"},{"caseNumber":"109554","date":"2007-04-19","type":"BC INSP","status":"FAILED"},{"caseNumber":"109755","date":"2007-04-20","type":"BC INSP","status":"PASSED"},{"caseNumber":"109758","date":"2007-04-20","type":"BC INSP","status":"PASSED"},{"caseNumber":"109761","date":"2007-04-20","type":"BC INSP","status":"FAILED"},{"caseNumber":"109764","date":"2007-04-20","type":"BC INSP","status":"FAILED"},{"caseNumber":"109768","date":"2007-04-20","type":"BC INSP","status":"PASSED"},{"caseNumber":"109838","date":"2007-04-20","type":"BC INSP","status":"FAILED"},{"caseNumber":"109841","date":"2007-04-20","type":"BC INSP","status":"FAILED"},{"caseNumber":"109853","date":"2007-04-20","type":"BC INSP","status":"FAILED"},{"caseNumber":"109855","date":"2007-04-20","type":"BC INSP","status":"FAILED"},{"caseNumber":"110161","date":"2007-04-23","type":"BC INSP","status":"PASSED"},{"caseNumber":"110162","date":"2007-04-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"110164","date":"2007-04-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"110166","date":"2007-04-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"110167","date":"2007-04-23","type":"BC INSP","status":"PASSED"},{"caseNumber":"110253","date":"2007-04-24","type":"BC INSP","status":"PASSED"},{"caseNumber":"110168","date":"2007-04-24","type":"BC INSP","status":"FAILED"},{"caseNumber":"110357","date":"2007-04-24","type":"BC INSP","status":"PASSED"},{"caseNumber":"110358","date":"2007-04-24","type":"BC INSP","status":"FAILED"},{"caseNumber":"110359","date":"2007-04-24","type":"BC INSP","status":"FAILED"},{"caseNumber":"110162","date":"2007-04-24","type":"BC INSP","status":"PASSED"},{"caseNumber":"110360","date":"2007-04-25","type":"BC INSP","status":"FAILED"},{"caseNumber":"110364","date":"2007-04-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"110365","date":"2007-04-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"110399","date":"2007-04-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"110402","date":"2007-04-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"110405","date":"2007-04-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"110406","date":"2007-04-25","type":"BC INSP","status":"PASSED"},{"caseNumber":"109554","date":"2007-04-26","type":"BC INSP","status":"PASSED"},{"caseNumber":"109547","date":"2007-04-26","type":"BC INSP","status":"PASSED"},{"caseNumber":"110617","date":"2007-04-26","type":"BC INSP","status":"PASSED"},{"caseNumber":"111014","date":"2007-04-26","type":"BC INSP","status":"PASSED"},{"caseNumber":"111019","date":"2007-04-26","type":"BC INSP","status":"FAILED"},{"caseNumber":"111020","date":"2007-04-26","type":"BC INSP","status":"PASSED"},{"caseNumber":"111021","date":"2007-04-26","type":"BC INSP","status":"FAILED"},{"caseNumber":"111023","date":"2007-04-27","type":"BC INSP","status":"FAILED"},{"caseNumber":"111024","date":"2007-04-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"111057","date":"2007-04-27","type":"BC INSP","status":"PASSED"},{"caseNumber":"111059","date":"2007-04-27","type":"BC INSP","status":"FAILED"},{"caseNumber":"111062","date":"2007-04-27","type":"BC INSP","status":"FAILED"},{"caseNumber":"111065","date":"2007-04-27","type":"BC INSP","status":"FAILED"},{"caseNumber":"111144","date":"2007-05-01","type":"BC INSP","status":"FAILED"},{"caseNumber":"111146","date":"2007-05-01","type":"BC INSP","status":"FAILED"},{"caseNumber":"111150","date":"2007-05-01","type":"BC INSP","status":"FAILED"},{"caseNumber":"111153","date":"2007-05-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"111154","date":"2007-05-02","type":"BC INSP","status":"FAILED"},{"caseNumber":"111319","date":"2007-05-02","type":"BC INSP","status":"FAILED"},{"caseNumber":"111321","date":"2007-05-02","type":"BC INSP","status":"FAILED"},{"caseNumber":"111322","date":"2007-05-02","type":"BC INSP","status":"PASSED"},{"caseNumber":"109838","date":"2007-05-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"111313","date":"2007-05-03","type":"BC INSP","status":"FAILED"},{"caseNumber":"111314","date":"2007-05-03","type":"BC INSP","status":"FAILED"},{"caseNumber":"111316","date":"2007-05-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"111717","date":"2007-05-21","type":"BC INSP","status":"FAILED"},{"caseNumber":"98439","date":"2007-05-21","type":"BC INSP","status":"FAILED"},{"caseNumber":"109841","date":"2007-05-21","type":"BC INSP","status":"PASSED"},{"caseNumber":"111154","date":"2007-05-23","type":"BC INSP","status":"PASSED"},{"caseNumber":"110168","date":"2007-08-13","type":"BC INSP","status":"PASSED"},{"caseNumber":"131891","date":"2007-10-18","type":"BC INSP","status":"PASSED"},{"caseNumber":"110359","date":"2008-05-28","type":"BC INSP","status":"PASSED"},{"caseNumber":"165799","date":"2008-06-17","type":"BC INSP","status":"FAILED"},{"caseNumber":"111314","date":"2008-09-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"111319","date":"2008-09-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"111065","date":"2008-09-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"108923","date":"2008-09-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"110358","date":"2008-09-23","type":"BC INSP","status":"FAILED"},{"caseNumber":"165799","date":"2008-10-06","type":"BC INSP","status":"CLOSED"},{"caseNumber":"111062","date":"2008-10-20","type":"BC INSP","status":"PASSED"},{"caseNumber":"111150","date":"2008-10-20","type":"BC INSP","status":"FAILED"},{"caseNumber":"109761","date":"2008-10-24","type":"BC INSP","status":"PASSED"},{"caseNumber":"109855","date":"2008-10-24","type":"BC INSP","status":"PASSED"},{"caseNumber":"109853","date":"2008-11-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"111144","date":"2008-11-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"108518","date":"2008-11-03","type":"BC INSP","status":"FAILED"},{"caseNumber":"110166","date":"2008-11-04","type":"BC INSP","status":"PASSED"},{"caseNumber":"111021","date":"2008-11-04","type":"BC INSP","status":"PASSED"},{"caseNumber":"111321","date":"2008-11-05","type":"BC INSP","status":"PASSED"},{"caseNumber":"98439","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"109545","date":"2008-12-01","type":"BC INSP","status":"FAILED"},{"caseNumber":"186923","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"109764","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"110164","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"111023","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"110360","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"111313","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"111059","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"186940","date":"2008-12-01","type":"BC INSP","status":"PASSED"},{"caseNumber":"109545","date":"2008-12-22","type":"BC INSP","status":"PASSED"},{"caseNumber":"226757","date":"2010-02-11","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"226757","date":"2010-02-24","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"108923","date":"2010-07-07","type":"BC INSP","status":"PASSED"},{"caseNumber":"108518","date":"2010-07-07","type":"BC INSP","status":"PASSED"},{"caseNumber":"111314","date":"2010-07-29","type":"BC INSP","status":"PASSED"},{"caseNumber":"248758","date":"2010-08-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"249856","date":"2010-08-31","type":"CI INSP","status":"FAILED"},{"caseNumber":"249856","date":"2010-09-23","type":"CI INSP","status":"FAILED"},{"caseNumber":"249856","date":"2010-10-08","type":"CI INSP","status":"PASSED"},{"caseNumber":"248758","date":"2010-10-08","type":"CI INSP","status":"PASSED"},{"caseNumber":"111019","date":"2010-11-08","type":"BC INSP","status":"FAILED"},{"caseNumber":"111146","date":"2010-11-08","type":"BC INSP","status":"FAILED"},{"caseNumber":"111717","date":"2010-11-08","type":"BC INSP","status":"FAILED"},{"caseNumber":"111319","date":"2010-11-08","type":"BC INSP","status":"FAILED"},{"caseNumber":"111065","date":"2010-11-08","type":"BC INSP","status":"FAILED"},{"caseNumber":"111065","date":"2010-11-08","type":"BC INSP","status":"CLOSED"},{"caseNumber":"111319","date":"2010-11-08","type":"BC INSP","status":"CLOSED"},{"caseNumber":"110358","date":"2010-11-08","type":"BC INSP","status":"CLOSED"},{"caseNumber":"110358","date":"2010-11-08","type":"BC INSP","status":"FAILED"},{"caseNumber":"111150","date":"2010-11-08","type":"BC INSP","status":"FAILED"},{"caseNumber":"111150","date":"2010-11-08","type":"BC INSP","status":"CLOSED"},{"caseNumber":"111019","date":"2010-12-30","type":"BC INSP","status":"PASSED"},{"caseNumber":"111146","date":"2010-12-30","type":"BC INSP","status":"PASSED"},{"caseNumber":"111065","date":"2011-03-08","type":"PRECOURT","status":"PASSED"},{"caseNumber":"111319","date":"2011-03-10","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"110358","date":"2011-03-10","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"111150","date":"2011-03-10","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"54764","date":"2011-05-17","type":"BC INSP","status":"PASSED"},{"caseNumber":"111717","date":"2011-05-23","type":"BC INSP","status":"PASSED"},{"caseNumber":"305411","date":"2011-10-27","type":"CI INSP","status":"PASSED"},{"caseNumber":"268785","date":"2012-05-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"268782","date":"2012-05-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"268786","date":"2012-05-03","type":"BC INSP","status":"PASSED"},{"caseNumber":"366991","date":"2013-01-24","type":"CI INSP","status":"FAILED"},{"caseNumber":"366991","date":"2013-03-06","type":"CI INSP","status":"PASSED"},{"caseNumber":"405869","date":"2013-10-07","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"405869","date":"2013-12-13","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"422782","date":"2014-03-19","type":"CI INSP","status":"FAILED"},{"caseNumber":"422821","date":"2014-03-19","type":"CI INSP","status":"FAILED"},{"caseNumber":"422788","date":"2014-03-19","type":"CI INSP","status":"FAILED"},{"caseNumber":"422821","date":"2014-04-23","type":"CI INSP","status":"FAILED"},{"caseNumber":"422788","date":"2014-04-23","type":"CI INSP","status":"PASSED"},{"caseNumber":"422782","date":"2014-04-23","type":"CI INSP","status":"PASSED"},{"caseNumber":"422821","date":"2014-05-08","type":"CI INSP","status":"PASSED"},{"caseNumber":"466479","date":"2015-01-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"466481","date":"2015-01-20","type":"CI INSP","status":"FAILED"},{"caseNumber":"466479","date":"2015-03-18","type":"CI INSP","status":"PASSED"},{"caseNumber":"466481","date":"2015-03-18","type":"CI INSP","status":"PASSED"},{"caseNumber":"510767","date":"2015-11-17","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"510767","date":"2015-12-29","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"510767","date":"2016-02-05","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"543375","date":"2016-07-08","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"543375","date":"2016-08-15","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"563151","date":"2016-11-09","type":"CI INSP","status":"FAILED"},{"caseNumber":"563308","date":"2016-11-10","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"563151","date":"2016-12-14","type":"CI INSP","status":"PASSED"},{"caseNumber":"563308","date":"2016-12-19","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"574140","date":"2017-02-27","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"574140","date":"2017-03-16","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"664922","date":"2018-11-26","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"664922","date":"2018-12-17","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"669593","date":"2019-01-07","type":"CI INSP","status":"FAILED"},{"caseNumber":"669593","date":"2019-03-12","type":"CI INSP","status":"PASSED"},{"caseNumber":"725409","date":"2020-02-26","type":"CI INSP","status":"FAILED"},{"caseNumber":"CF-2021-014647","date":"2021-03-03","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-014647","date":"2021-04-23","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-014647","date":"2021-06-03","type":null,"status":"PASSED"},{"caseNumber":"725409","date":"2021-06-08","type":null,"status":"PASSED"},{"caseNumber":"CF-2021-104621","date":"2021-10-26","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-104621","date":"2021-11-30","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-104621","date":"2021-12-10","type":null,"status":"PASSED"},{"caseNumber":"CF-2021-120003","date":"2021-12-21","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-120003","date":"2022-01-25","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-120003","date":"2022-01-31","type":null,"status":"PASSED"},{"caseNumber":"CF-2022-074883","date":"2022-07-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2023-070321","date":"2023-07-20","type":null,"status":"FAILED"},{"caseNumber":"CF-2023-070321","date":"2023-08-25","type":null,"status":"FAILED"},{"caseNumber":"CF-2023-070321","date":"2023-10-20","type":null,"status":"FAILED"},{"caseNumber":"CF-2022-074883","date":"2024-03-04","type":null,"status":"PASSED"},{"caseNumber":"CF-2024-016565","date":"2024-03-04","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-016565","date":"2024-03-26","type":null,"status":"PASSED"},{"caseNumber":"CF-2024-024430","date":"2024-03-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-024956","date":"2024-03-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-025024","date":"2024-03-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-024950","date":"2024-03-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-025024","date":"2024-05-01","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-024430","date":"2024-05-01","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-024956","date":"2025-02-04","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-024956","date":"2025-02-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-024430","date":"2026-03-24","type":null,"status":"FAILED"},{"caseNumber":"CF-2026-027258","date":"2026-03-24","type":null,"status":"FAILED"},{"caseNumber":"CF-2024-025024","date":"2026-03-24","type":null,"status":"FAILED"}],"inspYears":[{"y":2006,"fails":2,"passes":6},{"y":2007,"fails":35,"passes":60},{"y":2008,"fails":9,"passes":19},{"y":2010,"fails":11,"passes":8},{"y":2011,"fails":0,"passes":4},{"y":2012,"fails":0,"passes":3},{"y":2013,"fails":2,"passes":2},{"y":2014,"fails":4,"passes":3},{"y":2015,"fails":4,"passes":2},{"y":2016,"fails":3,"passes":4},{"y":2017,"fails":1,"passes":1},{"y":2018,"fails":1,"passes":1},{"y":2019,"fails":1,"passes":1},{"y":2020,"fails":1,"passes":0},{"y":2021,"fails":5,"passes":3},{"y":2022,"fails":2,"passes":1},{"y":2023,"fails":3,"passes":0},{"y":2024,"fails":7,"passes":2},{"y":2025,"fails":2,"passes":0},{"y":2026,"fails":3,"passes":0}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.95217168239286,"lng":-75.16615211657817,"geom":{"type":"Polygon","coordinates":[[[-75.165408101,39.952475423],[-75.165570122,39.95175605],[-75.165693392,39.951712337],[-75.166891942,39.951869758],[-75.166724486,39.952637675],[-75.165408101,39.952475423]]]},"liDistrict":"CENTRAL WEST","certifications":[{"number":"BC-2022-010309","type":"Facade Report","inspectionDate":"2013-10-28","result":"Safe","expirationDate":"2018-10-28","buildingId":"1526914"},{"number":"BC-2022-002129","type":"Facade Report","inspectionDate":"2018-05-09","result":"Safe","expirationDate":"2023-05-09","buildingId":"1526914"},{"number":"BC-2022-000039","type":"Special Hazards Certification","inspectionDate":"2021-12-28","result":"Certified","expirationDate":"2022-12-28","buildingId":"1526914"},{"number":"BC-2022-013372","type":"Fire Alarm Certification","inspectionDate":"2022-03-16","result":"Deficient","expirationDate":null,"buildingId":"1526914"},{"number":"BC-2022-015907","type":"Fire Alarm Certification","inspectionDate":"2022-05-26","result":"Certified","expirationDate":"2023-05-26","buildingId":"1526914"},{"number":"BC-2022-014244","type":"Sprinkler Certification","inspectionDate":"2022-08-01","result":"Deficient","expirationDate":null,"buildingId":"1526914"},{"number":"BC-2023-000716","type":"Special Hazards Certification","inspectionDate":"2022-12-30","result":"Certified","expirationDate":"2023-12-30","buildingId":"1526914"},{"number":"BC-2023-008845","type":"Facade Report","inspectionDate":"2023-03-30","result":"Safe with Repair","expirationDate":"2028-03-30","buildingId":"1526914"},{"number":"BC-2023-014418","type":"Sprinkler Certification","inspectionDate":"2023-04-25","result":"Deficient","expirationDate":null,"buildingId":"1526914"},{"number":"BC-2023-019149","type":"Fire Alarm Certification","inspectionDate":"2023-06-01","result":"Certified","expirationDate":"2024-06-01","buildingId":"1526914"},{"number":"BC-2023-019165","type":"Fire Alarm Certification","inspectionDate":"2023-06-01","result":"Certified","expirationDate":"2024-06-01","buildingId":"1526914"},{"number":"BC-2023-014550","type":"Special Hazards Certification","inspectionDate":"2023-06-26","result":"Certified","expirationDate":"2024-06-26","buildingId":"1526914"},{"number":"BC-2023-016926","type":"Special Hazards Certification","inspectionDate":"2023-07-21","result":"Certified","expirationDate":"2024-07-21","buildingId":"1526914"},{"number":"BC-2023-019024","type":"Fire Alarm Certification","inspectionDate":"2023-08-07","result":"Certified","expirationDate":"2024-08-07","buildingId":"1526914"},{"number":"BC-2023-021000","type":"Sprinkler Certification","inspectionDate":"2023-08-14","result":"Deficient","expirationDate":null,"buildingId":"1526914"},{"number":"BC-2023-022904","type":"Fire Alarm Certification","inspectionDate":"2023-09-30","result":"Certified","expirationDate":"2024-09-30","buildingId":"1526914"},{"number":"BC-2023-023187","type":"Sprinkler Certification","inspectionDate":"2023-11-09","result":"Certified","expirationDate":"2024-11-09","buildingId":"1526914"},{"number":"BC-2023-025670","type":"Special Hazards Certification","inspectionDate":"2023-12-04","result":"Certified","expirationDate":"2024-12-04","buildingId":"1526914"},{"number":"BC-2023-025661","type":"Special Hazards Certification","inspectionDate":"2023-12-06","result":"Certified","expirationDate":"2024-12-06","buildingId":"1526914"},{"number":"BC-2024-021231","type":"Special Hazards Certification","inspectionDate":"2024-07-12","result":"Certified","expirationDate":"2025-07-12","buildingId":"1526914"},{"number":"BC-2024-024547","type":"Fire Alarm Certification","inspectionDate":"2024-08-24","result":"Certified","expirationDate":"2025-08-24","buildingId":"1526914"},{"number":"BC-2024-030577","type":"Special Hazards Certification","inspectionDate":"2024-10-28","result":"Certified","expirationDate":"2025-10-28","buildingId":"1526914"},{"number":"BC-2025-000734","type":"Special Hazards Certification","inspectionDate":"2024-12-18","result":"Certified","expirationDate":"2025-12-18","buildingId":"1526914"},{"number":"BC-2025-002880","type":"Special Hazards Certification","inspectionDate":"2025-02-03","result":"Certified","expirationDate":"2026-02-03","buildingId":"1526914"},{"number":"BC-2025-024095","type":"Fire Alarm Certification","inspectionDate":"2025-05-21","result":"Certified","expirationDate":"2026-05-21","buildingId":"1526914"},{"number":"BC-2025-024092","type":"Fire Alarm Certification","inspectionDate":"2025-05-22","result":"Certified","expirationDate":"2026-05-22","buildingId":"1526914"},{"number":"BC-2025-020689","type":"Fire Alarm Certification","inspectionDate":"2025-06-21","result":"Certified","expirationDate":"2026-06-21","buildingId":"1526914"},{"number":"BC-2025-024951","type":"Fire Alarm Certification","inspectionDate":"2025-08-11","result":"Certified","expirationDate":"2026-08-11","buildingId":"1526914"},{"number":"BC-2026-012151","type":"Sprinkler Certification","inspectionDate":"2025-10-07","result":"Certified","expirationDate":"2026-10-07","buildingId":"1526914"},{"number":"BC-2026-001214","type":"Special Hazards Certification","inspectionDate":"2025-12-05","result":"Certified","expirationDate":"2026-12-05","buildingId":"1526914"},{"number":"BC-2026-004475","type":"Special Hazards Certification","inspectionDate":"2026-02-17","result":"Certified","expirationDate":"2027-02-17","buildingId":"1526914"},{"number":"BC-2026-013398","type":"Emergency and Standby Power Systems Certification","inspectionDate":"2026-05-09","result":"Certified","expirationDate":"2027-05-09","buildingId":"1526914"},{"number":"BC-2026-013399","type":"Emergency and Standby Power Systems Certification","inspectionDate":"2026-05-09","result":"Certified","expirationDate":"2027-05-09","buildingId":"1526914"},{"number":"BC-2026-020040","type":"Fire Alarm Certification","inspectionDate":"2026-06-23","result":"Certified","expirationDate":"2027-06-23","buildingId":"1526914"},{"number":"BC-2026-019669","type":"Special Hazards Certification","inspectionDate":"2026-07-13","result":"Certified","expirationDate":"2027-07-13","buildingId":"1526914"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19102","beds":null,"baths":null,"stories":43,"lotArea":107221,"zoning":"CMX5","grade":"B","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"1500 MARKET ST, PHILADELPHIA PA, 19102","mailOut":false,"appeals":[{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF ONE INTERNALLY ILLUMINATED FLATWALL SIGN","status":"OPEN","outcome":"Dismissed","date":"2017-10-04","number":"31093","relatedPermit":"792152"},{"type":"Zoning board appeal","grounds":"PERMIT FOR THE ERECTION OF ONE INTERNALLY ILLUMINATED FLATWALL SIGN","status":"OPEN","outcome":"Granted with conditions","date":"2017-08-23","number":"31148","relatedPermit":"792152"},{"type":"LIRB Violation Appeal","grounds":"Violation sites that we are in violation of Chapter 14-2000 of the Zoning Code.  In our review of the Code we understand that we do not meet the criteria of Chapter 14-2000 and our property is not located in any of the areas listed under Ch","status":"Closed","outcome":"Complete","date":"2023-08-02","number":"HA-2022-003562","relatedPermit":null},{"type":"LIRB Violation Appeal","grounds":"See Attached","status":"Closed","outcome":"Complete","date":"2025-03-12","number":"HA-2024-001324","relatedPermit":null},{"type":"ZBA Permit Denial - Variance","grounds":"PERMIT FOR USE AS PERSONAL VEHICLE SALES AND RENTAL WITH ALL OTHER USES IN THE SAME STRUCTURE AS PREVIOUSLY APPROVED; NO SIGN ON THIS APPLICATION.","status":"Completed","outcome":"Granted with conditions","date":"2024-09-23","number":"ZP-2024-001368","relatedPermit":"ZP-2024-001368"}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":247000000,"taxable":247000000,"land":32166300,"improvement":214833700,"taxableLand":32166300,"taxableImprovement":214833700,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":247000000,"taxable":247000000,"land":32166300,"improvement":214833700,"taxableLand":32166300,"taxableImprovement":214833700,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":329803100,"taxable":329803100,"land":66391020,"improvement":263412080,"taxableLand":66391020,"taxableImprovement":263412080,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":339681000,"taxable":339681000,"land":68366600,"improvement":271314400,"taxableLand":68366600,"taxableImprovement":271314400,"exemptLand":0,"exemptImprovement":0},{"y":2020,"v":349855200,"taxable":349855200,"land":70401440,"improvement":279453760,"taxableLand":70401440,"taxableImprovement":279453760,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":349855200,"taxable":349855200,"land":70401440,"improvement":279453760,"taxableLand":70401440,"taxableImprovement":279453760,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":349855200,"taxable":349855200,"land":70401440,"improvement":279453760,"taxableLand":70401440,"taxableImprovement":279453760,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":275000000,"taxable":275000000,"land":55000000,"improvement":220000000,"taxableLand":55000000,"taxableImprovement":220000000,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":250000000,"taxable":250000000,"land":50000000,"improvement":200000000,"taxableLand":50000000,"taxableImprovement":200000000,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":107000000,"taxable":107000000,"land":21400000,"improvement":85600000,"taxableLand":21400000,"taxableImprovement":85600000,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":250659200,"taxable":250659200,"land":50659200,"improvement":200000000,"taxableLand":50659200,"taxableImprovement":200000000,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":107000000,"taxable":107000000,"land":21974800,"improvement":85025200,"taxableLand":21974800,"taxableImprovement":85025200,"exemptLand":0,"exemptImprovement":0}],"taxNow":3508727,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"58881","date":"2007-02-28","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2007-02-28","scope":"FOR A DRY CLEANING DROP OFF AND PICK-UP STORE IN SPACE #L441 WITHIN AN EXISTING OFFICE BUILDING WITH USES AS PREVIOUSLY APPROVED."},{"number":"56875","date":"2007-03-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-04-16","scope":"INTERIOR FIT-OUT FOR DROP-OFF DRY CLEANERS IN OFFICE BUILDING AS PER PLANS"},{"number":"62162","date":"2007-03-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-17","scope":"FURNISH AND INSTALL VOICE AND DATA CABLING CATEGORY 6 (CC DIST)"},{"number":"65357","date":"2007-03-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-09-10","scope":"RELOCATE (1) 2X2 FXT. INSTALL (3) WALL SCONCE FXTS, (3) SWS, (9) RECEPTS. REUSE EXISTING CIRCUITS (CC DIST)"},{"number":"66406","date":"2007-04-03","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-04-16","scope":null},{"number":"66971","date":"2007-04-05","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-10-23","scope":"INTERIOR NON-BEARING DEMOLITION (UUPPR MEZZ. EAST SIDE)"},{"number":"66972","date":"2007-04-05","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2007-10-23","scope":"INTERIOR NON-BEARING DEMO (MEZZANINE WEST SIDE)"},{"number":"72885","date":"2007-05-01","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-28","scope":"RELOCATE 20 DIFFUSERS/REGISTERS (24TH FLOOR, TENANT HEALTHCARE)"},{"number":"73418","date":"2007-05-03","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-04-30","scope":"INTERIOR DEMOLITION"},{"number":"76409","date":"2007-05-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-28","scope":"REPLACE 41 EXISTING LIGHT FIXTURES WITH NEW ENERGY EFFICIENT LIGHT FIXTURES. REMOVE AND REINSTALL (IN SAME SPOT) 5 FIRE ALARM DEVICE FOR PAINT AND CEILING TILE INSTALLATION (CC DISTRICT)"},{"number":"75863","date":"2007-05-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-04-30","scope":"INT. ALT TO EXISTING OFFICES"},{"number":"73416","date":"2007-05-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-08-06","scope":"INTERIOR RENOVATIONS OF EXISTING COMMON CORRIDORS"},{"number":"79552","date":"2007-05-30","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2007-08-06","scope":"RELOCATE 10 DIFFUSERS/REGISTERS (24TH FLOOR - CORRIDOR & TOILETS)"},{"number":"71864","date":"2007-05-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-08-28","scope":"TENANT FIT-OUT AS PER PLANS"},{"number":"79935","date":"2007-06-01","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2007-08-06","scope":"REPAIR WATER DAMAGED: REMOVE LOWER 48\" OF 800 L.F OF 5/8\"GWB ON EXISTING PARTITIONS AND REPLACE WITH NEW 5/8 GWB.NO NEW PARTITIONS. REPLACE DAMAGED CEILING TILES AS REQUIRED"},{"number":"66312","date":"2007-06-01","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2021-02-24","scope":"INSTALL 16 EXIT LIGHTS, 336 LIGHT FIXTURES, FIRE ALARM, INTRUSION ALARM, 12 MESSAGE SIGNS, 32 CAMERAS, 4 PHONES & 49 SPEAKERS. NEW POWER & COMMUNICATION WIRING, PANELS EXISTING."},{"number":"80116","date":"2007-06-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-06-12","scope":"REPLACE FIXTURES"},{"number":"80120","date":"2007-06-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-07-23","scope":"INSTALL SINKS"},{"number":"84327","date":"2007-06-19","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-08-06","scope":null},{"number":"84334","date":"2007-06-19","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2007-08-28","scope":null},{"number":"74337","date":"2007-07-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-08-28","scope":"INSTALL WET SPRINKLER SYSTEM FOR TRASH ROOM P2 ONLY."},{"number":"88800","date":"2007-07-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2007-07-20","scope":"FIXTURE INSTALLATION"},{"number":"89848","date":"2007-08-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2007-11-26","scope":"REMOVE AND RECLOCATE (76) 2 X 4'S, (20) 2 X 2'S, (6) EXIT SIGNS. ADD (6) DEDICATED RECEPTACLES, (48) DUPLEX RECEPTACLES, (7) FURNITURE FEEDS, ALL CIRCUITRY IS EXISTING, TO BE RE-USED. (CC DIST)"},{"number":"96636","date":"2007-08-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-01-30","scope":"INTERIOR ALTERATIONS, FIT OUT, FINISHES OF EXISTING SPACE IN OFFICE BUILDING, AS PER SUBMITTED PLANS."},{"number":"91262","date":"2007-09-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (150-160) CAT 5E, PLENUM CABLES (LONGEST RUN 195') (CC DIST)"},{"number":"97877","date":"2007-09-13","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2007-09-13","scope":"FOR THE REMOVAL OF ALL ACCESSORY BANK SIGNS, AND FOR THE ERECTION OF SIX (6) FLATWALL WINDOW SIGNS (60\"X84\" EACH) AND ONE (1) CHANNEL LETTER SIGN (42\"X26'6\"). ALL SIGNS TO BE LOCATED BELOW THE BOTTOM OF THE SECOND FLOOR, (SIZE AND LOCATION AS SHOWN IN THE APPLICATION). SIGNS ACCESSORY TO AN EXISTING BANK AS PART OF AN EXISTING OFFICE BUILDING WITH PREVIOUSLY APPROVED USES AND SIGNS."},{"number":"104358","date":"2007-09-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-01-25","scope":"INTERIOR ALTERATIONS 5 SINKS"},{"number":"97878","date":"2007-09-20","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2009-03-13","scope":"REMOVE AND REPLACE 7 SIGNS AS SHOWN ON PLAN."},{"number":"104588","date":"2007-09-21","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-01-30","scope":null},{"number":"110440","date":"2007-10-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-30","scope":"INSTALL DUCTWORK"},{"number":"104337","date":"2007-10-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-06-21","scope":"INSTALL A NEW 600 AMP PANEL, 2 NEW 225AMP PANELS AND WIRE APPROX 40 HVAC UNITS (CC DIST)."},{"number":"110913","date":"2007-10-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-01-30","scope":"HVAC AND DUCTWORK"},{"number":"111216","date":"2007-11-05","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2008-01-30","scope":"AMEND PERMIT # 96636 TO INCLUDE RENOVATION OF EXISTING BATHROOMS."},{"number":"114498","date":"2007-11-08","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-09-29","scope":"FIXTURE INSTALLATION"},{"number":"114869","date":"2007-11-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-16","scope":"15TH STREET AND 3RD FLOOR, TEMP STANDBY 600KW GENERATOR WIRED INTO 3RD FLOOR EMERGENCY PANEL FOR POWER WHILE GENERATOR REPAIRS ARE CONDUCTED ON WEST TOWER. FROM NOVEMBER 23 TO NO LATER THAN DECEMBER 23."},{"number":"113067","date":"2007-12-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-09-14","scope":"DATE & VOICE CABLING, INSTALL 400 LOCATIONS CONSISTING OF 2 CAT6 PLENUM CABLES AND 1 CAT5 PLENUM CABLE. ALL CABLES WILL BE SUPPORTED WITH I HOOKS AS PER 2005 NEC (CC DISTRICT)"},{"number":"109071","date":"2007-12-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-28","scope":"INSTALLING NEW FIRE ALARM DEVICES AND WIRE FROM AN EXISTING FIRE ALARM HOUSE PANEL. INSTALLING NEW PANELS AND TRANSFORMERS AS PER NFPA72. (CC DIST)"},{"number":"103102","date":"2007-12-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-28","scope":"NEW LTS AND TIME CLOCK SYSTEM. PULLING NEW BRANCH CTS, RECEPTS AND POWER POLES. 135 FURN CONNECTIONS. CONNECTIONS (POWER) TO MECHANICAL EQUIP. WILL APPLY FOR A SEPARATE PANELS AND FEEDERS PERMIT. WILL APPLY FOR A SEPARATE FA. (CC DIST)"},{"number":"121790","date":"2008-01-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-04-02","scope":"REPLACE EXISTING MOTOR CONTROL FUSED SWITCH W/NEW VFD'S. INSTALL NEW CIRCUIT BREAKERS AND DISCONNECTS. (CC DIST)"},{"number":"131888","date":"2008-02-12","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-04-30","scope":"MINOR DEMOLITION OF CARPET, CEILING TILES AND GRID AND NON-LOAD BEARING PARTITIONS."},{"number":"130017","date":"2008-02-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-04-30","scope":"DEMO OF INTERIOR UNDER CEILING WALLS, PATCH CEILINGS AND NEW CARPET"},{"number":"133095","date":"2008-02-29","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-04-11","scope":"INTERIOR FIT OUT RENOVATION TO ACCOMODATE THE EXPANSION OF THE WANAMAKER TICKET OFFICE IN THE CENTRE SQUARE BLDG. SCOPE OF WORK INCLUDES DEMOLITION OF DRYWALL PARTITION REPAIRS TO LAYIN ACOUSTICAL CEILING NEW MILLWORK RELOCATION OF INTERIORE DOOR NEW DRYWALL PARTITION ADN PAINTING"},{"number":"135651","date":"2008-03-04","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-05-13","scope":null},{"number":"133218","date":"2008-03-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-11-05","scope":"DEMOLITION AND INTERIOR RENOVATIONS AS PER PLANS - 33RD THRU 36TH FLOORS"},{"number":"134710","date":"2008-03-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-30","scope":"DEMO EXISTING LIGHTING & POWER. INSTALL TEMPORARY LIGHTING, INSTALL (8) DUPLEX RECEPTACLES, (1) QUAD RECEPTACLE, (27) FURNITURE FEEDS, (3) FLOOR RECEPTACLES (CC DIST)"},{"number":"141291","date":"2008-03-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-04-24","scope":"REPLACE 1 FOR 1 EXISTING LIGHT FIXTURES, SWITCHING AND RECEPTCS NO NEW WIRING TO DEVICE, NEW EXISTING BRANCH CIRCUITS ARE TO BE REUSED AS PER 2005 NEC (CC DISTRICT)"},{"number":"111626","date":"2008-03-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-07-31","scope":"RENOVATIONS OF EXISTING OFFICE SPACE AS PER PLAN."},{"number":"145482","date":"2008-04-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2008-05-13","scope":"RELOCATION OF 25 SPRINKLER HEADS ON THE 10TH FLOOR OF AN EXISTING B USE OCCUPANCY."},{"number":"146532","date":"2008-04-18","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-11-13","scope":"DEMOLITION OF NON-BEARING WALLS"},{"number":"147420","date":"2008-04-23","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-03-13","scope":null},{"number":"148710","date":"2008-04-29","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-07-31","scope":"INTERIOR DEMOLITION OF NON BEARING PARTITIONS"},{"number":"144490","date":"2008-04-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-25","scope":"COMPLETE DEMOLITION OF THE FLOORS (33,34,35 & 36) LISTED ABOVE, NEW LIGHTING THROUGHOUT AND POWER. RE-USE ALL EXISTING CIRCUITRY FROM DEMO, AS PER 2005 NEC (CC DIST)"},{"number":"148859","date":"2008-05-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-09-03","scope":"FIXTURE INSTALLATION"},{"number":"149190","date":"2008-05-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-09-25","scope":"FIXTURE INSTALLATION"},{"number":"149600","date":"2008-05-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-06-20","scope":"FIXTURE INSTALLATION"},{"number":"149141","date":"2008-05-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-06-20","scope":"FIXTURE REPLACEMENTS"},{"number":"149772","date":"2008-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"RELOCATE 6 DIFFUSERS/REGISTERS (33RD FLOOR - CORRIDOR)"},{"number":"147632","date":"2008-05-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-11-05","scope":"ALTERATIONS TO OFFICE SPACES AND TO BASE BUILDING."},{"number":"146082","date":"2008-05-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-11-05","scope":"FIT-OUT FOR A DATA CENTER @ LOWER MEZZANINE LEVEL AND A RECORDS ROOM @ CONCOURSE LEVEL"},{"number":"145761","date":"2008-05-08","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2021-02-24","scope":"INSTALLATION OF (2) CATEGORY 5E, 4 PAIR, PLENUM RATED CABLES TO 100 DATA LOCATIONS, AS PER 2005 NEC (CC DIST) INSTALLATION OF (2) CATEGORY 5E, 4 PAIR, PLENUM RATED CABLES TO 100 DATA LOCATIONS, AS PER 2005 NEC (CC DIST)"},{"number":"146537","date":"2008-05-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-12-29","scope":"INTERIOR ALERATIONS 33RD FLOOR: RENOVATIONS TO RESTROOMS AND HALLWAYS PER PLAN, CLOSE OPENING IN FLOOR."},{"number":"147781","date":"2008-05-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-30","scope":"INSTALL (2) 400A PANEL BOARDS, WIRE (2) 125A AC UNITS, WIRE (21) VAV'S (VARIABLE AIR BOXES), WIRE (25) FPB'S (FAN POWERED BOXES WITH REHEAT) CC DIST)"},{"number":"150770","date":"2008-05-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-30","scope":"HVAC"},{"number":"150766","date":"2008-05-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-11-05","scope":"HVAC. WORK TO INCLUDE THE DEMOLITION OF EXISTING AND THE INSTALLATION OF NEW DUCTWORK,DIFFUSERS,REFRIGERANT PIPING, AND THE INSTALLATION OF ONE AIR CONDITIONING/CONDENSER (LIEBERT UNIT) ON THE 41ST AND 42ND FLOOR OF AN EXISTING B USE OCCUPANCY."},{"number":"151172","date":"2008-05-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-08","scope":"33RD FLOOR, REMOVE 32 LIGHTS AND REPLACE WITH 32 NEW 2X2 LIGHTS. REPLACE 8 EXIT SIGNS. ADD 2 NEW OCCUPANCY SENSORS. ALL CIRCUITS EXISTING"},{"number":"151158","date":"2008-05-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-08","scope":"33RD,34TH,35TH,36TH FL'S DEMO OLD HORN STROBES AND REPLACE WITH NEW SPEAKER STROBES. INSTALL NEW NAC PANELS ON FLOORS 33,34,35,36"},{"number":"155314","date":"2008-05-30","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":null},{"number":"155333","date":"2008-05-30","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-11-05","scope":null},{"number":"150504","date":"2008-05-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-29","scope":"INSTALLATION OF APPROXIMATELY (350) LIGHT FIXTURES, (21) EXIT LIGHTS, (80) SWITCHES, (150) RECEPTACLES, (13) FURNITURE FEEDS, (4) FLOOR RECEPTACLES, (2) AC UNIT FEEDS, (1) NEW PANEL, ALL AS PER 2005 NEC (CC DIST)"},{"number":"156336","date":"2008-06-04","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-11-05","scope":null},{"number":"152840","date":"2008-06-06","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2008-06-06","scope":"FOR THE REMOVAL OF UNDER GROUND VAULT AND FOR THE RECONFIGURATION OF EXISTING PARKING SPACES (510) FOR UNDERGROUND PUBLIC PARKING GARAGE TO (437) SPACES FOR PUBLIC PARKING (TWO LEVELS), IN THE SAME BULIDING AS OFFICE SPACES FLOORS 2 THRU 36 AND GROUND FLOOR RETAIL AS PREVIOUSLY APPROVED, NO SIGNS ON THIS APPLICATION."},{"number":"157067","date":"2008-06-09","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-09-30","scope":null},{"number":"153824","date":"2008-06-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-08-19","scope":"INSTALL 100 LOCATIONS CONSISTING OF 2 CAT 5E PLENUM CABLES, ALL PLENUM CABLES WILL BE SUPPORTED WITH CADDY J HOOKS, ALL SLEEVES AND PENETRATIONS WILL BE FIRE STOPPED AS PER 2005 NEC (CC DISTRICT)"},{"number":"149675","date":"2008-06-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-11-06","scope":"INTERIOR RENOVATIONS"},{"number":"152611","date":"2008-06-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-29","scope":"INSTALL 1 NEW PANEL, 7 SPEAKER STROBES, 1 STROBE ONLY, 1 SPEAKER ONLY (FIRE ALARM SYSTEM) (CC DIST)"},{"number":"154518","date":"2008-06-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-08","scope":"INSTALL 898 CAT 6 PLENUM RATED CABLES FOR VOICE/DATA. INSTALL COPPER & FIBER RISER CABLE."},{"number":"158917","date":"2008-06-17","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"INTERIOR NON-BEARING DEMOLITION (FLOOR VAULT AREA, SUB-BASEMENT LEVEL)"},{"number":"158927","date":"2008-06-17","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"INTERIOR NON-BEARING DEMOLITION (8TH FLOOR, WEST TOWER CENTER SQ.)"},{"number":"156413","date":"2008-06-18","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"INSTALL DUCT AND DIFFUSERS, VAV BOXES ETC. WITHIN THE 25TH FLOOR AS PER PLANS."},{"number":"161110","date":"2008-06-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2008-07-25","scope":"FIXTURE INSTALLATION"},{"number":"158366","date":"2008-06-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-10-01","scope":"INSTALL 208 CATEGORY 6 PLENUM DATA CABLES, 280' LONGEST RUN, INSTALL 154 CATEGORY 5E PLENUM VOICE CABLES, INSTALL COPPER AND FIBER RISER, AS PER 2005 NEC (CC DIST)"},{"number":"157661","date":"2008-06-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-25","scope":"REMOVE AND RELOCATE 20 PENDANT FIXTURES, ADD 78 NEW DUPLEX RECEPTS, ADD NEW LOW VOLTAGE LIGHTING CONTROL PANEL, ADD 12 - 2X2 FIXTURES AS PER 2005 NEC (CC DISTRICT)"},{"number":"162463","date":"2008-07-03","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"INTERIOR NON-BEARING DEMOLITION, WEST SIDE 10TH FLOOR CENTRE SQ."},{"number":"160616","date":"2008-07-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-03-13","scope":"INSTALL NEW MECHANICALS, INCLUDING DUCTWORK."},{"number":"164060","date":"2008-07-11","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-09-30","scope":null},{"number":"161617","date":"2008-07-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-09-25","scope":"FURNISH AND INSTALL 16 KVA UPS, (2) NEW 120/208 VOLT PANELS, (1) NEW 277/480 VOLT, 200 AMP PANEL, NEW 30 KVA AS PER 2005 NEC (CC DIST)"},{"number":"128230","date":"2008-08-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-12-16","scope":"CONVERT EXISTING UNOCCUPIED BANK VAULT INTO A TWO-LEVEL PARKING SPACE WITH ACCESS FROM EXISTING PARKING GARAGE."},{"number":"168971","date":"2008-08-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"CONVERT EXISTING UNOCCUPIED BANK VAULT INTO A TWO-LEVEL PARKING SPACE WITH ACCESS FROM EXISTING PARKING GARAGE. REFER TO PARENT A/P#128230 FOR HVAC PLANS."},{"number":"170534","date":"2008-08-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2008-11-05","scope":"COMMERCIAL TENANT FITOUT"},{"number":"173992","date":"2008-09-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-07-27","scope":"FIXTURE INSTALLATION"},{"number":"172635","date":"2008-09-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-03-13","scope":"CONVERT EXISTING WET SPRINKLER SYSTEM IN UPPER LEVEL VAULT TO DRY SPRINKLER SYSTEM AND MODIFY NEW DRY SYSTEM TO ACCOMODATE NEW PARKING GARAGE LAYOUT. EXTEND DRY SYSTEM TO PROTECT NEW LOWER LEVEL VAULT PARKING GARAGE AS PER NFPA NO 13 AND LOCAL CODES"},{"number":"169114","date":"2008-09-08","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2021-02-24","scope":"AUDIO VISUAL AS PER 2005 NEC (CC DIST) AUDIO VISUAL AS PER 2005 NEC (CC DIST)"},{"number":"174169","date":"2008-09-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-09","scope":"HVAC AS PER PLANS"},{"number":"177185","date":"2008-09-15","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":null},{"number":"173916","date":"2008-09-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-16","scope":"DEMOLITION OF BOTH FLOORS, INSTALL TEMPORARY LIGHTING, INSTALL 7 NEW 120/208 VOLT PANELS, INSTALL NEW RECEPTS AND LIGHTING , RE FEED EXISTING RECEPTS AS PER 2005 NEC (CC DISTRICT)"},{"number":"175150","date":"2008-09-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-21","scope":"RELOCATE EXISTING 480 VOLT SVS, ADD (1) TRANSFORMER, 1 NEW PANEL, 2 RELOCATED PANELS, 38 FXTS, 22 EXITS, 12 NEW RECEPTS, 2 EXHAUST FAN FEEDS AND 12 NEW FIRE DEVICES. (CC DIST)"},{"number":"175758","date":"2008-10-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-22","scope":"INSTALLATION OF VAV BOXES NOTED ON DRAWINGS AS PER PLANS. SPECIFICATIONS GRD'S BEING SUPPLED BY OTHERS"},{"number":"181339","date":"2008-10-06","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"INTERIOR NON-BEARING DEMOLITION - 9TH FLOOR WEST TOWER (REMOVE CARPET/CEILINGS)"},{"number":"182013","date":"2008-10-09","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2008-12-26","scope":"INTERIOR NON-BEARING DEMOLITION - CENTRE SQUARE, 11TH FLOOR WEST"},{"number":"166952","date":"2008-10-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-16","scope":"SUITE E3500- INSTALL PANEL AND DEVICES FOR CLEAN AGENT SUPPRESSION SYSTEM ."},{"number":"180232","date":"2008-10-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-12-09","scope":"VOICE AND DATE CABLING AND APPLICABLE, RISER CABLES FOR FIT OUT AS PER 2005 NEC (CC DISTRICT)"},{"number":"179602","date":"2008-10-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-01-16","scope":"NEW AUDIO & VISUAL AS PER 2005 NEC (CC DISTRICT)"},{"number":"187361","date":"2008-11-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-06-12","scope":"INSTALL (2) NEW FLOOR DRAINS"},{"number":"189595","date":"2008-11-24","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"INSTALL 16 CAT 5E PLENUM CABLES, LONGEST FUN 225' AS PER 2005 NEC (CC DISTRICT) INSTALL 16 CAT 5E PLENUM CABLES, LONGEST FUN 225' AS PER 2005 NEC (CC DISTRICT)"},{"number":"193729","date":"2008-12-19","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2009-06-01","scope":"DEMOLITION REMOVING OF NON BEARING INTERIOR PARTITIONS. FOR OFFICE BLDG."},{"number":"188938","date":"2008-12-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-08-31","scope":"INSTALLATION OF THE FOLLOWING EQUIPMENT 13 VAV'S PER FLOOR, 6 AMS PER FL., 4 60X12, 2 40X16 6 DPT'S PER FL., SMOKE DAMPERS, OTHER WORK TO INCLUDES CAPING OF PIPE, AND THE PATCHING OF DUCTWORK. FOR AN OFFICE BLDG."},{"number":"194845","date":"2008-12-30","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2009-06-18","scope":"INTERIOR DEMOLITION OF NON BEARING PARTITIONS AND KITCHEN EQUIPMENT"},{"number":"197338","date":"2009-01-20","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2009-06-01","scope":"INTERIOR DEMOLITION OF NON LOAD BEARING WALLS ONLY. NO OTHER WORK ALLOWED UNDER THIS PERMIT."},{"number":"201232","date":"2009-02-17","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"INSTALL OWNER SUPPLIED FIXTURES: 20 HI-HATS, 6 WALL SCONCES, INSTALL 12 20 AMP, 110 VOLT OUTLETS, AS PER 2005 NEC (CC DIST) INSTALL OWNER SUPPLIED FIXTURES: 20 HI-HATS, 6 WALL SCONCES, INSTALL 12 20 AMP, 110 VOLT OUTLETS, AS PER 2005 NEC (CC DIST)"},{"number":"202457","date":"2009-02-24","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-06-01","scope":"DRYWALL THRU OUT ON PERIMETER WALLS, OVER EXISTING STUDDED WALLS FOR BAR/RESTAURANT (COSMETIC WORK) NO FIRE RATED ASSEMBLIES TO BE DISTURBED"},{"number":"203422","date":"2009-03-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-06-12","scope":"INTERIOR RENOVATIONS; PERMIT TO INCLUDE MINOR INTERIOR DEMOLITION AND THE INSTALLATION OF NON COMBUSTIBLE PARTITIONS ON THE 24TH FLOOR,TENET HEALTHCARE SPACE CENTRE SQUARE WEST."},{"number":"206353","date":"2009-03-25","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-06-08","scope":null},{"number":"206180","date":"2009-03-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-06-16","scope":"INTERIOR ALTERATIONS TO OFFICE SPACE WITH ALL NEW FINISHES LOCATED IN EXISITING BLDG."},{"number":"206897","date":"2009-03-31","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-06-12","scope":"HVAC, INCLUDING DUCTWORK AS PER PLANS."},{"number":"208861","date":"2009-04-07","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2009-06-18","scope":"INTERIOR NON LOAD-BEARING DEMOLITION (11TH FLOOR WEST TOWER)"},{"number":"211416","date":"2009-04-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"PROVIDE AND INSTALL 44 DATA CABLES AND 46 VOICE CABLLES, PROVIDE AND INSTALL WALL MOUNT RACK AND PATCH PANELS, TERMINATE AND TEST CABLES, AS PER 2005 NEC (CC DIST)"},{"number":"211489","date":"2009-04-20","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2009-09-10","scope":null},{"number":"209240","date":"2009-04-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-25","scope":"INSTALL (32) DUPLEX RECEPTACLES, (12) DOUBLE DUPLEX RECEPTACLES, (30) 2X2 FIXTURES, (28) DOWNLIGHTS, (12) SINGLE POLE SWITCHES, AS PER 2005 NEC (CC DIST)"},{"number":"207988","date":"2009-04-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-06-12","scope":"PARTIAL DEMO OF EXISTING WET SYSTEM AND INSTALLATION OF NEW WET SYSTEM ON 41ST FLR TO CONNECT TO EXISTING SYSTEM AS PER PLANS."},{"number":"214760","date":"2009-05-07","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":null,"scope":null},{"number":"213041","date":"2009-05-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-09-10","scope":"INTERIOR ALTERATIONS AS PER PLAN."},{"number":"212836","date":"2009-06-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2009-09-10","scope":"HVAC ALTERATIONS ON THE 11TH FLOOR AS PER APPROVED PLANS."},{"number":"212676","date":"2009-06-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-10-15","scope":"FURNISH & INSTALL 12 SPEAKER/STROBES & 3 RELAYS."},{"number":"217537","date":"2009-06-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-11-05","scope":"(38) DUPLEX RECEPTACLES, (44) FURNITURE FEEDS, (12) POKE THRUS, (14) GFI RECEPTACLES, (72) TELE/DATA STUBS, (250) 2 X 4 FIXTURES, (6) NEW 120 VOLT PANELS, AS PER 2005 NEC (CC DIST)"},{"number":"220821","date":"2009-06-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-10-12","scope":"FIXTURE INSTALLATION"},{"number":"220124","date":"2009-07-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2009-11-05","scope":"INSTALL 18 SPEAKER/STROBES, 8 STROBES, 1 SMOKE DETECTOR & 1 BOOSTER PANEL."},{"number":"222148","date":"2009-08-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-03-15","scope":"INSTALL 182 LOCATIONS CONSISTING OF 2 CAT 6 PLENUM CABLES, ALL CABLING WILL BE INSTALLED IN JHOOKS, ALL SLEEVES AND FIRE RATED WALLS WILL BE FIRE STOPPED AS PER 2005 NEC(CC DISTRICT)"},{"number":"234080","date":"2009-09-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-01-12","scope":"INTERIOR ALTERATIONS: RETRO-FIT EXISTING DUNKIN' DONUTS TENANT SPACE PER PLAN"},{"number":"240708","date":"2009-10-05","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-12-07","scope":null},{"number":"160483","date":"2009-10-29","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2009-11-19","scope":"INSTALL CLEAN AGENT FIRE SUPPRESSION SYSTEM IN COMPUTER ROOM"},{"number":"248750","date":"2009-12-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-12-19","scope":"INTERIOR ALTERATIONS: 36TH,37TH,38TH, & 40TH FLOORS AS PER PLANS"},{"number":"252836","date":"2009-12-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-01-12","scope":"REMOVE AND REPLACE (8) COFFEE URNS, REPIPE WATER LINES = 30 LINEAR FEET,INSTALL NEW FIXTURES (2 PIECE BATHROOM)"},{"number":"253194","date":"2009-12-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-12-19","scope":"INSTALL DUCTWORK AND MECHANICAL UNITS ON THE 36TH, 37TH, 38TH AND 40TH FLOORS"},{"number":"253602","date":"2010-01-06","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-12-19","scope":"94 FIXTURES WITH PIPING REFER TO APPROVED PLANS"},{"number":"257791","date":"2010-01-19","work":"Fast form building","type":"L_FFORM","description":"FAST FORM BUILDING PERMIT","status":"COMPLETED","completedDate":"2010-12-19","scope":null},{"number":"257379","date":"2010-02-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-05-04","scope":"HORIZONTAL VOICE/DATA CABLING PER PLANS."},{"number":"220542","date":"2010-03-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-05-26","scope":"ERECT SIDEWALK SHELTER PLATFORM"},{"number":"258039","date":"2010-03-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-12-10","scope":"INSTALL 1800 LIGHT FIXTURES, 255 OCCUPANCY SENSORS, 66 SWITCHES, 7 LIGHTING CONTROL PANELS, 96 RECEPTACLES, 18 HVAC FEEDS, 1 208/120V PANEL & 7 FIRE ALARM STROBES. REPLACE EXISTING FIXTURES WITH ENERGY EFFICIENT FIXTURES."},{"number":"264371","date":"2010-03-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-04-30","scope":"INTERIOR ALTERATIONS OF OFFICE"},{"number":"266624","date":"2010-03-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2010-04-30","scope":"INSTALLATION OF SINK, CONNECT TO EXISTING SERVICES"},{"number":"267985","date":"2010-03-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-04-30","scope":"HVACM INCLUDING DUCTWORK, AS PER PLAN"},{"number":"269516","date":"2010-04-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-28","scope":"FIRE ALARM: ADD (11) NEW SPEAKER STROBES (2 IN CORRIDOR, 9 IN TENANT SPACE), TIE INTO EXISTING PANEL AS PER NFPA-72 (CC DIST)"},{"number":"267227","date":"2010-04-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-28","scope":"ADD 42 (2X4) 11-DOWN LTS,5 EXITS, 3 TASK LTS, 19 SWITCHES,45 RECEPTACLES, ALL NEW CIRCIUITS TIE TO EXISTING PANELS AS PER 2008 NEC (CC DISTRICT)"},{"number":"269626","date":"2010-04-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-04-30","scope":"RELOCATE 44 SPRINKLERS ON THE 24TH FLOOR OF THE CENTER SQUARE WEST BLDG"},{"number":"277683","date":"2010-05-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2010-06-03","scope":"RELOCATION OF 9 DIFFUSERS/REGISTERS(COMMERCIAL)"},{"number":"278366","date":"2010-05-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-06-03","scope":"RELOCATE (4) SPRINKLERS"},{"number":"283249","date":"2010-06-04","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2010-09-22","scope":"INTERIOR DEMO"},{"number":"279254","date":"2010-06-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL FIRE ALARM DEVICES AND ASSOCIATED WIRING PER PLANS AND CODES AS PER NFPA 72 (CC DISTRICT)"},{"number":"283253","date":"2010-06-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2010-09-22","scope":"INTERIOR RENOVATION OF EXISTING SPACE PER PLAN."},{"number":"280069","date":"2010-06-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-07-26","scope":"EXPANSION OF EXISTING CLEAN AGENT FIRE SUPPRESSION TO COVER FILE STORAGE AREA AS PER PLANS."},{"number":"287448","date":"2010-06-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-08-03","scope":"RELOCATE EXISTING POWER FOR (2) NEW SIGNS, REMOVE (5) EXISTING PENDANT FIXTURES AND REPLACE WITH DIFFERENT STYLE AS PER 2008 (CC DIST)"},{"number":"287416","date":"2010-06-24","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2010-06-24","scope":"FOR OUTDOOR SEATING COMPLETELY WITHIN THE PROPERTY ACCESSORY TO AN EXISTING RESTAURANT/BAR WITH ACCESSORY RETAIL SALE OF FOOD FOR TAKE-OUT ON THE GROUND FLOOR AND CONCOURSE LEVEL OF AN EXISTING OFFICE BUILDING WITH USES AS PREVIOUSLY APPROVED."},{"number":"299201","date":"2010-09-08","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-02-22","scope":"INTERIOR NON-BEARING DEMOLITION (11TH FLOOR, EAST TOWER)"},{"number":"301476","date":"2010-10-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-09-24","scope":"PHASE 1 CONCRETE REPAIRS AT TWO CENTRE SQUARE TOWERS: WEST FAÇADE OF EAST TOWER AND EAST FAÇADE OF WEST TOWER PHASE 1 DOES NOT INCLUDE WORK ON ANY FAÇADE ABUTTING PUBLIC SIDEWALKS NO SCAFFOLDING OR CLOSURE OR PARTIAL CLOSURE OF SIDEWALK WITHOUT STREET'S DEPT.STREET CLOSURE PERMIT. SEPARATE BUILDING PERMIT REQUIRED SHELTER PLATFORM"},{"number":"272009","date":"2010-11-05","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-03-01","scope":"INSTALL WET CHEMICAL SYSTEM, WET ANSUL R-102, INTO REPLACED NEW HOOD FOR RESTAURANT PER MANUFACTURUR'S INSTRUCTIONS AND BY A LICENSED INSTALLER ONLY."},{"number":"311740","date":"2010-11-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2010-12-06","scope":"RELOCATE (4) SPRINKLERS ON 3RD FL. OF SUITE 335"},{"number":"312201","date":"2010-11-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-06-01","scope":"RELOCATE 35 EXISTING SPRINKLER HEADS (27TH FLOOR)"},{"number":"311259","date":"2010-11-17","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-06-01","scope":"INTERIOR ALTERATIONS TO BASE BUILDING AS PER PLAN."},{"number":"311631","date":"2010-11-29","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-08","scope":"FURNISH AND INSTALL (6) DUPLEX RECEPTACLES UTILIZING EXISTING CIRCUITRY, NO NEW CIRCUITING REQUIRED, AS PER 2008 NEC (CC DIST)"},{"number":"315544","date":"2010-12-08","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-06-01","scope":"INSTALL 12 AIR DIFFUSERS & EXHAUST REGISTERS"},{"number":"315957","date":"2010-12-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-06-01","scope":"REMOVE AND REINSTALL WITH NO ADDITIONAL PIPING: (8) WATER CLOSETS, (3)URINALS, (12)LAVATORIES"},{"number":"317988","date":"2010-12-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-02-22","scope":"RELOCATE 70 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"314997","date":"2011-01-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-08","scope":"FIRE ALARM: FURNISH AND INSTALL (12) SPEAKER STROBES AS PER NFPA-72 (CC DIST)"},{"number":"317796","date":"2011-01-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-02-22","scope":"REPLACEMENT OF TEN LAV SINK FAUCETS (ONLY IN RESTROOM) REPLACE EXISTING PANTRY SINK AND INSTALL (1)NEW PANTRY SINK"},{"number":"278560","date":"2011-01-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-03-09","scope":"INSTALLATION OF ONE NEW KITCHEN EXHASUST HOOD BY A LICENSED CONTRACTOR ONLY."},{"number":"317212","date":"2011-01-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-03-22","scope":"MINOR DEMO AND REBUILD OF OFFICES AND CONFERENCES TO INCLUDE: NEW FLOOR AREA, TENANT SPACES,PARTITIONS,DOORS, BREAKROOM,AND COPY ROOM"},{"number":"315216","date":"2011-01-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-03-08","scope":"1 FOR 1 REPLACEMENT OF 25 CORRIDOR LIGHT FIXTURES."},{"number":"320588","date":"2011-01-13","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-02-14","scope":"INTERIOR NON-LOAD BEARING DEMOLITION (9TH FLOOR WEST TOWER)"},{"number":"320337","date":"2011-01-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-04-26","scope":"INTERIOR ALTERATIONS TO 9TH FLOOR AS PER PLANS FOR OFFICE SPACE. NONCOMBUSTIBLE AND PROTECTED CONSTRUCTION AND A FULLY SPRINKLERED BUILDING ONLY. C.O.N.R."},{"number":"322024","date":"2011-01-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-04-26","scope":"(1) PROVIDE (2) SINKS WITH ALL PLUMBING PIPING (2) PROVIDE (2) NEW SINKS IN COUNTER TOP WITH NO PIPING, FOR DEMONSTRATION PURPOSES ONLY"},{"number":"318151","date":"2011-01-31","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-03-22","scope":"INSTAL NEW HVAC INCLUDING DUCTWORK & VAV BOXES PER PLANS"},{"number":"323048","date":"2011-02-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-04-26","scope":"RELOCATE 106 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"317342","date":"2011-02-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-27","scope":"INSTALL (94) DUPLEX RECEPTACLES,(8) GFI RECEPTACLES,(183) 1X4 FIXTURES, (140) DOWN LIGHTS,(4) COVE LIGHTS,(3) PENDANTS,(17) EXITS,(15) SWITCHES, (20) OCCUPANCY SENSORS,(18) FURNITURE FEEDS,(4) VAV,(2) PANELS, AS PER 2008 NEC (CC DIST)"},{"number":"322846","date":"2011-02-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-02-14","scope":"AUDIO VISUAL AS PER 2008 NEC"},{"number":"319092","date":"2011-02-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-03-15","scope":"VOICE AND DATA CABLING TO APPROX 182 LOCATIONS THRU-OUT THE 11TH FLOOR OF 1500 MARKET ST.,COPPER BACKBONE CABLE BETWEEN 9TH FLOOR TELEPHONE AND 11TH FLOOR TELEPHONE CLOSET AS PER 2008 NEC"},{"number":"322841","date":"2011-02-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-08-02","scope":"INTERIOR RENOVATIONS OF EXISTING CORRIDOR & RESTROOM FINISHES INCLUDING ADA TOILETS. NEW FINISHES,PARTITIONS, LIGHTING COMPLIANT WITH THE 2009IECC."},{"number":"324533","date":"2011-02-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-08-02","scope":"REPLACING 22 EXISTING FIXTURES,9 TOILETS,10 LAVATORY AND 3 URINALS,INSTALL 1 NEW TOILET AND 1 NEW LAVATORY WITH SANITARY AND WASTE"},{"number":"323511","date":"2011-02-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-12-02","scope":"INSTALLATION OF TEMPORARY PEDESTRIAN PROTECTION SCAFFOLDING ON MARKET ST,15TH ST AND 16TH ST."},{"number":"320702","date":"2011-02-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-03-11","scope":"49 SPEAKERS,5 HORNS STROBES,15 STROBES,2 RELAYS,1 NAC EXTENDER PANEL AS PER 2008 NEC"},{"number":"325232","date":"2011-02-16","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-05-12","scope":"install 31 new energy effiecent 2x2s suplied by owner,install 4 new down lights,replace 8 exits lights as per 2008 nec"},{"number":"322032","date":"2011-02-22","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-26","scope":"INTERIOR FITOUT, EXISTING & NEW DUCTWORK AS PER PLAN."},{"number":"326093","date":"2011-02-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-08-02","scope":"RELOCATE 20 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"326733","date":"2011-02-25","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-05-26","scope":"INTERIOR DEMOLITION OF NON-LOAD BEARING WALLS FOR FUTURE FITOUT"},{"number":"322039","date":"2011-02-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-05-05","scope":"INSTALL LIGHTING AND POWER THRU-OUT SPACE AS PER 2008 NEC"},{"number":"327282","date":"2011-03-01","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-07-01","scope":"RELOCATION OF 7 SPRINKLER HEADS"},{"number":"324266","date":"2011-03-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-05-05","scope":"FURNISH AND INSTALL NEW FIRE ALARM SYSTEM THROUGHOUT SPACE AS PER NFPA-72 (CC DIST)"},{"number":"325555","date":"2011-03-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-08-25","scope":"FOR INTERIOR ALTERATIONS WITHIN AN EXISTING TENANT SPACE TO INCLUDE NEW PARTITIONS, BUILT-IN SERVICE COUNTERS AND FINISHES. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. THIS WORK ACTIVITY SHALL BE PERFORMED BY A CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED FOR THIS ACTIVITY."},{"number":"322286","date":"2011-03-11","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2011-03-11","scope":"REMOVAL OF ALL EXISTING WACHOVIA SIGNS INCLUDING WINDOW SIGN (ATM INSIDE BANK SIGN- LOCATED IN WINDOW ON MARKET ST. FRONTAGE) AND REPLACEMENT THE OF TWO (2) FLAT WALL SIGNS (39\"X186\" EA.) LOCATED ABOVE THE BOTTOM OF THE SECOND FLOOR AND REPLACEMENT OF ONE (1) FLAT WALL SIGN (2'11\"X7'PIN LETTERS), LOCATED BELOW THE BOTTOM OF THE SECOND FLOOR, SIZE & LOCATION AS SHOWN IN THE APPLICATION. THREE PROPOSED FLAT WALL SIGNS ACCESSORY TO EXISTING BANK AS PART OF AN EXISTING OFFICE BUILDING WITH PUBLIC GARAGE AND ALL USES AND REMAINING ACCESSORY SIGNS AS PREVIOUSLY APPROVED."},{"number":"323589","date":"2011-03-14","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2011-04-04","scope":"C.O. NOT REQUIRED MEMO ISSUED ALONG WITH THE PREVIOUS ISSUED/FINALED BUILDING PERMIT APP. #060509044, PLAN # 2238-A-06. FOR SINGLE TENANT OFFICE SPACE ON 12TH FLOOR ONLY."},{"number":"329384","date":"2011-03-21","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2011-05-18","scope":"ERECTION OF WALL SIGNS FOR BANK"},{"number":"329014","date":"2011-03-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-10-17","scope":"DEMO INTERIOR NON LOAD BEARING WALLS/SINKS. CONSTRUCT NEW WALLS AND PANTRY AREA, GLASS SLIDING DOORS. RELOCATE SPRINKLER AND RELOCATE DIFFUSERS. NO CHANGE IN USE CLASSIFCATION. EXISTING USE."},{"number":"325247","date":"2011-04-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-10-28","scope":"PHASE 2 GROUND WORK CONCRETE REPAIR ON FACADE"},{"number":"314683","date":"2011-04-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-04-27","scope":"TIE NEW ANSUL SYSTEM INTO FIRE ALARM SYSTEM,RELOCATE EXISTING POWER 6 DEVICES TO CONFORM TO NEW LAYOUT AS PER 2008 NEC"},{"number":"332642","date":"2011-04-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-07-01","scope":"INTERIOR RENOVATIONS FOR FITOUT."},{"number":"339312","date":"2011-05-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-07-27","scope":"RELAMP LIGHT FIXTURES."},{"number":"339341","date":"2011-05-05","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-07-01","scope":"RELOCATE 13 SPRINKLERS ON THE 25TH FLOOR-OFFICE BLDG"},{"number":"341591","date":"2011-05-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-08-10","scope":"INTERIOR FITOUT PER PLAS"},{"number":"343207","date":"2011-05-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-12-22","scope":"RELOCATE 14 SPRINKLER HEADS (WEST TOWER, 29TH FLOOR)"},{"number":"343208","date":"2011-05-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-08-10","scope":"RELOCATE 30 SPRINKLER HEADS (EAST TOWER, 33RD FLOOR)"},{"number":"343601","date":"2011-05-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-10-12","scope":"FURNISH AND INSTALL LIGHTING AND POWER THROUGHOUT SPACE AS PER 2008 NEC (CC DIST)"},{"number":"324305","date":"2011-06-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-04-30","scope":"INSTALL 276 CAT6 CABLES AND 70 CAT5E CABLES,1 24 STANDS ARMORED MM FIBER CABLES AND 1 12 STRAND FIBER CABLES AS PER 2008 NEC"},{"number":"338249","date":"2011-06-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-12-09","scope":"INTERIOR RENOVATIONS FOR WANAMAKER TICKET AGENCY EXPANSION IN SUITE 635. SCOPE OF WORK INCLUDES; DRYWALL PARTITION & SOFFIT; DOORS AND FRAMES, ACOUSTICAL CEILINGS AND PAINTING IN OFFICE."},{"number":"339305","date":"2011-06-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-08-01","scope":"INSTALL LIGHTING & POWER THROUGHOUT SPACE."},{"number":"347220","date":"2011-06-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL (7) TELE/DATA DROPS AS PER 2008 NEC (CC DIST)"},{"number":"341477","date":"2011-06-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-12-22","scope":"INTERIOR ALTERATIONS TO CREATE IMPROVED OFFICE SPACE."},{"number":"346844","date":"2011-06-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-08-10","scope":"FURNISH AND INSTALL 3 NEW VAV BOXES, DUCT AND NEW AIR DEVICES FOR NEW OFFICE LAYOUT"},{"number":"348382","date":"2011-06-21","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-10-17","scope":"RELOCATION OF (8) SPRINKLERS ON 27TH FLOOR IN TOWERS OF OFFICE/COMMERCIAL BLDG."},{"number":"341965","date":"2011-06-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-07-01","scope":"FOR THE PARTIAL DEMOLITION OF EXISTING MECHANICAL SYSTEM AND FOR THE INSTALLATION OF NEW DUCTS, REGISTERS AND DIFFUSERS, VAV BOXES AND AIR DEVICES FOR EXISTING OFFICE AS PER PLANS."},{"number":"343250","date":"2011-06-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-08","scope":"FRUNISH AND INSTALL 2 SPEAKER/STROBES AND 4 STROBES AS PER NFPA72 (CC DISTRICT)"},{"number":"345953","date":"2011-06-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-08-01","scope":"FURNISH AND INSTALL LIGHTING AND POWER THROUGHOUT SPACE AS PER 2008 NEC (CC DIST)"},{"number":"349590","date":"2011-06-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-08-10","scope":"33RD FLOOR - FURNISH AND INSTALL (1)ONE SINK - CONNECT TO EXISTING SERVICES"},{"number":"349107","date":"2011-06-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-08-10","scope":"33RD FLOOR - FURNISH AND INSTALL (1)SINK - CONNECT TO EXISTING SERVICES"},{"number":"350490","date":"2011-07-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-08-25","scope":"INTERIOR RENOVATIONS TO EXISTING CONCOURSE AS PER PLANS."},{"number":"351823","date":"2011-07-08","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-08-25","scope":"RELOCATE 17 SPRINKLERS ON THE CONCOURSE LEVEL."},{"number":"351929","date":"2011-07-11","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2011-08-02","scope":"INTERIOR DEMO OF NON-LOAD BEARING PARTITIONS FOR OFFICE BLDG."},{"number":"352406","date":"2011-07-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-08","scope":"FURNISH AND INSTALL 4 DUPLEX RECEPTACLES, 3 GFCI RECEPTACLES, 2 DEDICATED GFCI RECEPTACLE, 3 TELE/ DATA STUBS, 5 SINGLE POLE SWITCHES AS PER 2008 NEC"},{"number":"351958","date":"2011-07-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"INTERIOR ALTERATIONS AS PER PLANS."},{"number":"348934","date":"2011-07-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"LOW VOLTAGE INSTALLATIONS FOR (15) NEW AND (8) VOICE CABLES, ALSO (4) EXISTING VOICE CABLES TO BE RELOCATED, AS PER 2008 NEC (CC DIST)"},{"number":"348912","date":"2011-07-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-08-08","scope":"FURNISH AND INSTALL (8) SPEAKER/STROBES, (1) NAC PANEL, (1) SIGNAL ZAM, AS PER NFPA-72 (CC DIST)"},{"number":"348203","date":"2011-07-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-02-14","scope":"FURNISH & INSTALL ELEVEN (11) SPEAKER/STROBES, TWO (2) STROBES ONE (1)PANEL, & ONE (1) SIGNAL ZAM AS PER 2008 NEC"},{"number":"353901","date":"2011-07-21","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"RELOCATE 405 SPRINKLER HEADS (CONCOURSE, 39TH & 40TH FLOORS WEST TOWERS)"},{"number":"353835","date":"2011-07-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"HVAC INCLUDING DUCTWORK AS PER PLANS. 88 REGISTERS/DIFFUSERS FIRE RATED ASSEMBLIES ARE TO BE MAINTAINED AT ALL TIMES."},{"number":"355235","date":"2011-07-28","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"39TH AND 40TH FLOORS - FURNISH AND INSTALL (4)SINKS - (2)SINKS ON THE 39TH FLOOR - (2)SINKS ON THE 40TH FLOOR - CONNECT TO EXISTING SERVICES"},{"number":"353606","date":"2011-07-29","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-01-06","scope":"INTERIOR ALTERATIONS, DEMO AND UPGRADES TO FINISHES FOR OFFICE RENOVATIONS, TENANT FIT UP. NO CHANGE IN USE OR OCCUPANCY."},{"number":"347988","date":"2011-08-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RELOCATE 50 VOICE AND DATA CABLE STATIONS,INSTALL 40 NEW CAT 6 PLENUM CABLES FOR DATA APLICATIONS,PROVIDE AND INSTALL CAT 6 PATCH CABLES TO CONNECT STATION EQUIPMENT TO NETWORK EQUIPMENT AS PER 2008 NEC"},{"number":"357299","date":"2011-08-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-01-06","scope":"RELOCATE (33) SPRINKLER HEADS ON THE 8TH AND 9TH FLOORS"},{"number":"356987","date":"2011-09-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-06-13","scope":"FURNISH & INSTALL LIGHTING & POWER THROUGHOUT SPACE AS PER 2008 NEC (CC DISTRICT)"},{"number":"356534","date":"2011-09-02","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-01","scope":"HVAC INCLUDING DUCTWORK ON THE 8TH AND 9TH FLOORS AS PER PLANS."},{"number":"355816","date":"2011-09-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-09","scope":"1 DEMO EXISTING,1 TEMP LITING,9-GFI, QUAD RECEPS,15 DED RECEPTS IN DATA CTR,20 DED RECEPS,170 RECEPTS,38 QUAD RECEPS, 11 FIRE RATED FLOOR RECEPTS,139 V/D,105 MOTION SENSORS,10 DIMMER SWITCHES,4 -3 WAY SWITCHES,753 LITING FIXTURES,3 EX FANS, 3 WATER HTRS,1 RELOCATE VAV WIRING,2 CABLE TRAY,1 WIRE & CONNECT UPS AS PER 2008 NEC (CC DISTRICT) INSTALL FIRE ALARM SYSTEM AS PER NFPA72"},{"number":"364605","date":"2011-09-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION TO EXISTING SPACE, INSTALL 9 LIGHT FIXTURES,1 WALL SWITCHES, 7 RECEPTACLES, 3 EXIT FIXTURE, RE USE EXISTING CIRCUITS FROM DEMOLITION, NO ANTICAPATED CHANGE IN LOAD AS PER 2008 NEC"},{"number":"366709","date":"2011-10-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2011-10-26","scope":"RELOCATE 2 SPRINKLER HEADS (1ST FLOOR)"},{"number":"368221","date":"2011-10-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-10-17","scope":"RELOCATE 4 DIFFUSERS FOR NEW OFFICE LAYOUT"},{"number":"363207","date":"2011-10-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2011-12-22","scope":"INSTALL (6) NEW VAV BOXES AND (20) NEW DIFUUSERS WITH ASSOCIATED DUCT"},{"number":"355520","date":"2011-10-27","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2011-10-27","scope":"ERECTION OF A FLATWALL SIGN(SIZE AND LOCATION AS SHOWN ON THE APPLICATION). ACCESSORY TO A PUBLIC PARKING GARAGE/FINANCIAL INSTITUTION AS PART OF AN EXISTING OFFICE BUILDING WITH ALL USES AND ACCESSORY SIGNS AS PREVIOUSLY APPROVED."},{"number":"369644","date":"2011-11-14","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2011-11-14","scope":"FOR THE ERECTION OF EIGHT(8) PANEL ANTENNAS ON THE ROOF AND FOR THE INSTALLATION OF PECO CABINET ON THE 43RD FLOOR . SIZE AND LOCATION AS SHOWN IN THE APPLICATION. FOR A WIRELESS SERVICE IN THE SAME BUILDING WITH EXISTING WIRELESS SERVICES AND PARKING, BANK, RETAIL STORES, MECHANICAL SERVICES FOR BUILDING, OFFICES AND RESTAURANT AS PREVIOUSLY APPROVED."},{"number":"371836","date":"2011-12-02","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2012-03-21","scope":"INSTALLATION OF (1) WALL SIGN FOR PARKING/OFFICE"},{"number":"382452","date":"2012-02-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-03-01","scope":"LOW VOLTAGE VOICE/DATA CAB. RELOCATE 27 WORK STATIONS ON 8TH FL AND INSTALL 43 NEW WORK STATIONS. RELOCATE 32 STATIONS ON 9TH FL AND INSTLL 47 NEW STATIONS AS PER 2008 NEC(COMMERCIAL)(CC DIST)"},{"number":"397071","date":"2012-04-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-26","scope":"ALTERATIONS TO MECHANICAL SYSTEM TO INCLUDE REMOVE AND REPLACE EXISTING COOLING UNITS AND DUCTWORK"},{"number":"402110","date":"2012-05-04","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-01-14","scope":"1 PANTRY SINK"},{"number":"399782","date":"2012-05-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-06-22","scope":"ADDING OFFICE SPACE ON 18TH FLOOR AND FRAMING FOR BUSINESS"},{"number":"406250","date":"2012-05-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-09-25","scope":"REMOVE & RELOCATE25-2X2'S/INSTALL 10 NEW DUPLEX RECEPTS RE-USING EXISTING CIRCUITRY/12 TELE/DATA STUB UPS AS PER 2008 NEC"},{"number":"408129","date":"2012-06-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-07-23","scope":"INTERIOR ALTERATIONS, AS PER PLANS"},{"number":"403628","date":"2012-06-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-10-04","scope":"INTERIOR ALTERATIONS / RE-FIT EXISTING CENTRE SQUARE STARBUCKS RETAIL / COMM'L GROUND FLOOR SPACE PER PLAN"},{"number":"410485","date":"2012-06-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-01-17","scope":"INSTALL 2 FLOOR SINKS REINSTALL EXISITING INDIRECT WASTE TO NEW FLOOR SINKS"},{"number":"411869","date":"2012-06-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"4 FURNITURE SYSTEM FEEDS 1-GFCI RECEPTACLE 1-COPIER RECEPTACLE 2-SINGLE POLE SWITCHES 12-RELOCATE EXISTING LIGHTING 5-DUPLEX RECEPTACLES PER 2008 NEC"},{"number":"413015","date":"2012-06-25","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-07-18","scope":"RELOCATE 5 SPRINKLER HEADS, LOWER MEZZANINE"},{"number":"413953","date":"2012-06-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-07-18","scope":"RELOCATE 4 DIFFUSERS"},{"number":"414925","date":"2012-07-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-17","scope":"PROVIDE & INSTALL 7 VOICE /DATA CABLES FOR 7 WORKSTATIONS (HIGH RISE)(CC DISTRICT)"},{"number":"405594","date":"2012-07-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-13","scope":"RELOCATE 56 CAT6 LENUM CABS FOR VOICE AND DATA, INSTALL 56 NE CAT6 PLENUM CABS, PROVIDE AND INSTALL CAT6 PATCH CABS TO CONNECT STATION EQUIPMENT TO NETWORK EQUIPMENT AS PER 2008 NEC(HIGH RISE OFFICE)(CC DIST)"},{"number":"419489","date":"2012-07-31","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2012-09-28","scope":"RELOCATE 5 SPRINKLER HEADS."},{"number":"415397","date":"2012-08-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2012-09-28","scope":"INTERIOR ALTERATIONS PARTIAL 32ND FLOOR - WEST TOWER OFFICE SPACE PER PLANS"},{"number":"421297","date":"2012-08-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2012-09-28","scope":"RELOCATE 6 DIFFUSERS"},{"number":"421547","date":"2012-08-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-10-05","scope":"RELOCATE 21 EXISTING LIGHTS 5 FIXTURES INSTALL 8 POWER OUTLET NO TELE/COMMUNICATION NO FIRE ALARM INCLUDED UTILIZE EXISTING ELECTRICAL SERVICE PER 2008 NEC (OFFICE BLDG)"},{"number":"421299","date":"2012-08-13","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2012-09-28","scope":"INSTALL 8 LAVS, RELOCATE 3 URINALS AND INSTALL 1 PANTRY SINK(HIGH RISE OFFICE BLDG)"},{"number":"420557","date":"2012-08-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-01-14","scope":"RENOVATE OFFICE INTO MEDIATATION SPACE."},{"number":"424658","date":"2012-09-07","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-04-12","scope":"ALTERATIONS TO BUILDING CORRIDOR."},{"number":"434945","date":"2012-10-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2012-12-10","scope":"REMOVE & RELOCATE 17 HI HATS & DUPLEX RECEPTACLES PER 2008 NEC (OFFICE SPACE)"},{"number":"457131","date":"2013-03-05","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-04-08","scope":"RELOCATE 1 EXISTING SPRIKLER HEAD TO ACCOMMODATE WALL AND CEILING LAYOUT. (30TH FLOOR)"},{"number":"456618","date":"2013-03-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-06-24","scope":"RENOVATIONS OF EXISTING TENANT SPACE TO INCLUDE CERTIFICATE OF OCCUPANCY AS PER PLANS."},{"number":"462757","date":"2013-04-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-07-19","scope":"TENANT FIT OUT PER PLANS."},{"number":"465692","date":"2013-04-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-05-31","scope":"INTERIOR ALTERATIONS TO COMMERCIAL OFFICE."},{"number":"464885","date":"2013-04-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-09-10","scope":"INTERIOR ALTERATIONS TO AN EXISTING OFFICE BUILDING AS PER PLANS."},{"number":"467600","date":"2013-04-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-05-31","scope":"RELOCATE (10) EXISTING SPRINKLER HEADS IN ORER TO ACCOMMODATE TENANT WALL AND CEILING LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES - MEZZANINE LEVEL, LM - 525"},{"number":"466346","date":"2013-04-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-05-31","scope":"INSTALLATION OF KITCHEN SINK, CONNECT TO EXISTING SANITARY VENT AND WATER"},{"number":"462637","date":"2013-05-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-07-08","scope":"FOR THE INSTALLATION OF ONE (1) CEILING MOUNTED TRANSFER FAN (TF) UNIT, ONE (1) RETURN GRILLE (RG), & ALL ASSOCIATED SUPPLY, RETURN, & EXHAUST DUCTWORK TO TIE-IN TO EXIST. HVAC SYSTEM WITHIN AN EXIST. HIGH-RISE MIXED-USE OFFICE BUILDING."},{"number":"469068","date":"2013-05-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-08-16","scope":"RELOCATION (3) SPRINKLERS ON THE 28TH FLOOR IN TOWER WATSON."},{"number":"469782","date":"2013-05-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-11-13","scope":"RELOCATE EXISTING HI HATS (15) AND RELOCATE EXISTING RECEPTACLES (6) PER 2008 NEC (OFFICE BLDG)"},{"number":"462172","date":"2013-05-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-08-16","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 28TH FLOOR OF AN EXISTING BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS AND FOR THE INSTALLATION OF CABINETRY. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK."},{"number":"471044","date":"2013-05-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-08-03","scope":"RELOCATE 4 DUPLEX AND 2 GFI RECEPTACLES TO ACCOMODATE NEW OFFICE SPACE CONFIGURATION - AS PER 2008 NEC"},{"number":"471717","date":"2013-05-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-08-03","scope":"RELOCATE 920) 2X2 FIXTURE, CHANGE (5) WALL SWITCH TO MOTION SWITCH RELOCATE (10) RECEPTACLES ADD (1) NEW COPIER RECEPTACLES AND 1 EXIT LIGHT PER 2008 (OFFICE SPACE)"},{"number":"472579","date":"2013-05-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-08-26","scope":"RELOCATE (5) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW TENANT LAYOUT, AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"473961","date":"2013-05-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-07-19","scope":"RELOCATE FOUR AIR DIFFUSERS"},{"number":"474476","date":"2013-05-30","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2013-08-19","scope":"FURNISH LABOR AND MARTERIAL TO RELOCATE 5 AIR DEVICES"},{"number":"474690","date":"2013-05-31","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-02-28","scope":"RELOCATE (6) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT FITOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"476172","date":"2013-06-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-09-10","scope":"REMOVE (26) EXISTING FIXTURES ANBD RE-INSTALL AFTER FLOORS AND WALLS HAVE BEEN TILED IN OFFICE BLDG."},{"number":"476639","date":"2013-06-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-27","scope":"RELOCATE 20-OUTLETS, 3-2X4 FIXTURES & REMOVE 2-HI HATS AS PER NEC 2008 (OFFICE BLDG)"},{"number":"476971","date":"2013-06-12","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-04-22","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ONLY AND REMOVAL OF DEBRIS (LOWER MEZZ.)"},{"number":"478040","date":"2013-06-19","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-01-06","scope":"INTERIOR NON-LOAD BEARING DEMOLITION ONLY & DEBRIS REMOVAL (15TH FLOOR)"},{"number":"479539","date":"2013-06-26","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2013-12-27","scope":"INTERIOR NON-LOAD BEARING DEMOLITION ONLY AND REMOVAL OF DEBRIS (16TH FLOOR)"},{"number":"475939","date":"2013-06-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-12-24","scope":"INSTALLATION OF LGTS FIXTURES AS SHOWN ON DRAWING (OFFICE BLDG) AS PER NEC 2008"},{"number":"482076","date":"2013-07-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-08-22","scope":"RELOCATING 1 SPRINKLER ON THE GROUND FLOOR OF DUNKIN DONUTS AT CENTRE SQUARE"},{"number":"480597","date":"2013-07-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-12-30","scope":"INTERIOR ALTERATIONS TO EXISTING TENANT SPACE."},{"number":"482335","date":"2013-07-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-09-25","scope":"RELOCATE 3-DEDICATED RECPTS FOR VENDING MACHINES AS PER NEC 2008 (OFFICE BLDG)"},{"number":"474903","date":"2013-07-16","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-06-24","scope":"SOME MODIFICATION OF EXISTING PLUMBING IS REQUIRED TO ACCOMMODATE NEW ARCH LAYOUT"},{"number":"485585","date":"2013-07-26","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-03-20","scope":"INTERIOR DEMOLITION OF TOILET ROOMS ON 14TH FLOOR. 501 SQUARE FEET, INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILINGS ONLY. NO OTHER WORK ALLOWED UNDER THIS PERMIT. SEPARATE PERMITS REQUIRED FOR RENOVATION. NO STRUCTURAL CHANGES. MUST MAINTAIN ALL CODE REQUIRED FIRE RATING ON WALL AND FLOOR/CEILING ASSEMBLIES. THREE SETS OF PLANS DRAWN TO PROFESSIONAL QUALITY ARE TO BE SUBMITTED FOR REVIEW AND APPROVAL BY THE DEPARTMENT BEFORE WORK ON RENOVATION STARTS. CONTACT STREETS DEPARTMENT FOR DUMPSTER PERMIT AND FOOTWAY CLOSURE PERMITS. NO DEMOLITION TO FIRE RATED ASSEMBLIES."},{"number":"485497","date":"2013-07-26","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2013-12-14","scope":"INTERIOR NON-LOAD BEARING DEMOLITION & REMOVAL OF DEBRIS (17TH FLOOR)"},{"number":"485500","date":"2013-07-26","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2013-12-14","scope":"INTERIOR NON-LOAD BEARING DEMOLITION & REMOVAL OF DEBRIS (14TH FLOOR)"},{"number":"485803","date":"2013-08-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-02-26","scope":"REPLACE EXISTING FIXTURES: (10)LAVATORIES, (2)URINALS, (7)WATER CLOSETS"},{"number":"487528","date":"2013-08-06","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2013-12-30","scope":"RELOCATE (2) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW TENANT LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES (GROUND FLOOR)."},{"number":"487088","date":"2013-08-12","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2013-11-12","scope":"INSTALLATION OF (2)KITCHEN SINKS AND (2) FLOOR DRAINS, CONNECT TO EXISTING SANITARY, VENT AND WATER"},{"number":"486522","date":"2013-08-14","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-09-17","scope":"GENERAL INTERIOR DEMO AND RENOVATIONS, UPGRADES TO FINISHES, PARTITIONS, WALL COVERINGS, CEILING GRIDS, REPLACE FIXTURES, CARPETING AND BASE, PREP WORK. ADDITIONAL PERMITS IF MODIFIED : ELECTRICAL, HVAC, SPRINKLERS."},{"number":"485586","date":"2013-08-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-02-26","scope":"TOILET ROOM RENOVATION INCLUDING FLOORING, TOILET PARTITIONS AND ACCESSORIES, NEW CEILING TILE AS PER PLANS.- ADDITIONAL PERMITS ARE REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND SUPPRESSION."},{"number":"491726","date":"2013-08-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-01-03","scope":"REMOVE EXISTING LIGHTING, FURNISH & INSTALL 11-NEW 2X2, 2-DOWNLIGHT & 4-NEW OCCUPENCY SINSORS IN RESTROOMS AS PER NEC 2008 (OFFICE BLDG)"},{"number":"482919","date":"2013-09-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-06-12","scope":"TENANT FIT OUT OF PARTIAL LOWER MEZZ FLOOR AND FLOORS 14, 15, 16, 17 OF EAST TOWER CONSISTING OF OPEN PLAN OFFICES, SPACES, CONFERENCE ROOMS, AND OTHER SUPPORT SPACES. ALTERATIONS INCLUDE COMMUNICATING STAIR BETWEEN FLOORS 15-17. NO CHANGE IN OCCUPANCY CLASSIFICATION. SEPARATE PERMITS SEPARATE PERMITS REQUIRED FOR MODIFICATIONS TO 14TH FLOOR TOILET ROOM, MECHANICAL, ELECTRICAL, AND PLUMBING WORK."},{"number":"491469","date":"2013-09-18","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-04-14","scope":"REMOVING CARPET. CEILING TILES AND GRID, FLEX DUCTWORK, INTERIOR NON LOAD BEARING WALLS.. ETC"},{"number":"493959","date":"2013-09-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-02-03","scope":"FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13 TO TIE INTO AN EXISTING FIRE SUPPRESSION SYSTEM AS PER APPROVED PLANS."},{"number":"495903","date":"2013-09-20","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-06-25","scope":"RELOCATING 4 SPRINKLERS IN CENTRE SQUARE BATHROOMS ON THE LOWER MEZZANINE."},{"number":"499555","date":"2013-10-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2013-11-08","scope":"REPLACE & ADD LIGHTING FIXTURE & DEVICES FOR RENOVATION, RELOCATE COMMUNICATION DEVICES AS PER NEC 2008 (RESTAURANT)"},{"number":"501874","date":"2013-10-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-03-02","scope":"RELOCATE (96) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW TENANT LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES (32ND FLOOR)"},{"number":"494061","date":"2013-10-25","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-04-22","scope":"INSTALL SANITARY WASTE & VENT, INSTALL DOMESTIC HOT & COLD WATER PIPING, INSTALL OF FIXTURES (OFFICE BLDG)"},{"number":"500914","date":"2013-10-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-03-02","scope":"INSTALLATION OF: WATER CLOSET, LAVATORY, KITCHEN SINK"},{"number":"497874","date":"2013-10-31","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-03-02","scope":"TENANT FIT OUT AS PER PLANS, INCLUDING SKETCHES SK2-1 THROUGH SK2-6.RAMPS MUST BE EQUIPPED WITH HANDRAILS ON BOTH SIDES AND INSTALLATION MUST COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. LIGHTING MUST COMPLY WITH THE 2009 IECC AS NOTED ON ATTACHED SHEET. NO CHANGE IN OCCUPANCY CLASSIFICATION."},{"number":"498977","date":"2013-11-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-04-22","scope":"MECHANICAL ALTERATIONS AS PER PLANS."},{"number":"504143","date":"2013-11-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL A DEDICATED 20A, 120V BRANCH CIRCUIT AND DUPLEX OUTLET FOR NEW COPY/FAX MACHINE... IN ACCORDANCE WITH 2008 NEC"},{"number":"504533","date":"2013-11-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-03-02","scope":"HVAC, INCLUDING DUCTWORK AND MECHANICAL EQUIPMENT. ALL NEW DUCTOWRK MUST COMPLY WITH CHAPTER 5 OF THE 2009 IECC-SEE ATTACHED SHEET."},{"number":"504617","date":"2013-12-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-02","scope":"ALTERNATION TO TENANT FLOOR,INSTALL NEW LIGHTING FIXTURES,INSTALL BRANCH CIRCUIT WIRING FOR NEW OUTLETS PER 2008 NEC (OFFICE SPACE )"},{"number":"509408","date":"2013-12-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-06-18","scope":"RELOCATE EXISTING HEADS TO CONFORM TO NEW CEILING GRID REPLACE OLD HEADS WITH NEW - OFFICE BLDG"},{"number":"505995","date":"2013-12-16","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2013-12-16","scope":"REPLACE EXISTING LETTERS, INSTALL NEW 1'X4'X10'-6 15/16\" LETTERS ON EXISTING BACKGROUND PANEL, REFACE EXISTING ATM SIGN FACE, NEW INTERIOR SIGN-NON ILLUM PLATE LETTERS MOUNTER ON BACKGROUND PANEL, REMOVE 4 WINDOW SIGNS, INSTALL 3 NEW INTERIOR ILLUM SIGN BANDS, REMOVE 2 WINDOW SIGNS, INSTALL 2 NEW TERIOR ILLUM SIGNS- BANK"},{"number":"506003","date":"2013-12-16","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2014-02-19","scope":"REPLACE EXISTING LETTERS, INSTALL NEW 1'X4'X10'-6 15/16\" LETTERS ON EXISTING BACKGROUND PANEL, REFACE EXISTING ATM SIGN FACE, NEW INTERIOR SIGN-NON ILLUM PLATE LETTERS MOUNTER ON BACKGROUND PANEL, REMOVE 4 WINDOW SIGNS, INSTALL 3 NEW INTERIOR ILLUM SIGN BANDS, REMOVE 2 WINDOW SIGNS, INSTALL 2 NEW TERIOR ILLUM SIGNS- BANK"},{"number":"510413","date":"2014-01-24","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-04-14","scope":"INSTALL NEW DEVICES TO EXISTING AS PER NFPA72 (OFFICE BLDG)(CC DISTRICT)"},{"number":"514876","date":"2014-02-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-02","scope":"SECURITY INSTALLATION PER 2008 NEC (OFFICE SPACE)"},{"number":"495456","date":"2014-02-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-05-22","scope":"RENOVATION W/NEW LGTS,WIRING & DEVICES, CHANGE/RELOCATE FIRE ALARM DEVICES, 4-NEW ELEC PANEL, 1-TRANS-WILL SUBMIT ANY NEW F/A DRAWINGS AS THEY ARE RECEIVE FROM SIMPLEX GRINNELL AS PER NEC 2008 & NFPA 72 (OFFICE)"},{"number":"500779","date":"2014-02-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-04-28","scope":"FURNISH AND INSTALL 819 CATEGORY 6 PLENUM CABLES,13 R66 PLENUM CABLES,SOUND MASKING SYSTEM (LONGEST RUN 175') INSTALLATION TO COMPLY WITH ARTICLES 300.21 & 800 OF THE 2008 NEC."},{"number":"521515","date":"2014-02-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-03-20","scope":"RELOCATE (6) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMMODATE WALL AND CEILING LAYOUTS AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"530428","date":"2014-04-14","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-11-06","scope":"FURNISH LABOR & MATERIAL TO RELOCATE 13 AIR DEVICES - OFFICE"},{"number":"531655","date":"2014-04-22","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2014-04-22","scope":"TEMPORARY CERTIFICATE OF OCCUPANCY FOR THE LOWER MEZZANINE ALSO FLOORS 14,15,16 AND 17 ONLY."},{"number":"531937","date":"2014-04-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-05-08","scope":"RELOCATE 814 HEADS."},{"number":"515614","date":"2014-05-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-07-07","scope":"INSTALLATION OF (UP TO 2) 120VOLT/20AMP CIRCUITS FOR FREEZER IN STOCK AREA AS PER NEC 2008 (COMM/RESTAURANT/RETAIL)***SEE LOG***"},{"number":"532524","date":"2014-05-06","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-06-18","scope":"RELOCATE HEADS TO NEW CEILING HEIGHT."},{"number":"538693","date":"2014-05-30","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-01-14","scope":"REMOVE EXISTING ROOFING DOWN TO EXISTING CONCRETE DECK, REPLACE WITH NEW 3.5\" INSULATION, AND NEW SIPLAST ROOF SYSTEM TO WATER TIGHT CONDITIONS. INSTALL NEW ROOF COVER AS PER MANUFACTURER'S SPECIFICATIONS. . NEW ROOF COVERINGS SHALL NOT BE INSTALLED WITHOUT FIRST REMOVING ALL EXISTING LAYERS WHEN THE ROOF HAS TWO OR MORE APPLICATIONS OF ANY TYPE OF ROOF COVERING. SUBMIT ROOF CERTIFICATION TO INSPECTOR FOR FINAL INSPECTION"},{"number":"548038","date":"2014-07-10","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2014-08-15","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON THE 12TH FLOOR ONLY."},{"number":"551047","date":"2014-07-23","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-01-21","scope":"RELOCATE 6 DIFFUSERS"},{"number":"550255","date":"2014-07-28","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-02-24","scope":"LEVEL II ALTERATION OF EXISTING OFFICE SPACE"},{"number":"551051","date":"2014-08-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-12-18","scope":"FOR LEVEL II ALTERATIONS TO AN THE 12TH AND 14TH FLOOR OF AN EXISTING BUILDING, ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF PARITION WALLS, PROVIDE FINSIHES AND APPLIANCES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED.SEPARATE PERMTIS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK."},{"number":"554874","date":"2014-08-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"FOR THE INSTALLATION OF A NEW HVAC SYSTEM THROUGHOUT AN OFFICE BUILDING AS SHOWN IN APPROVED PLANS. WORK INCLUDES NEW APPLIANCES, REGISTERS/DIFFSUERS AND ALL SUPPLEMENTAL DUCTWORK."},{"number":"556472","date":"2014-08-18","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"RELOCATING SPRINKLER HEADS ON THE 12TH & 14TH FLOORS OF THE WEST TOWER."},{"number":"555386","date":"2014-08-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"INSTALL KITCHEN SINKS (4), CONNECT TO EXISTING- 2- PER FLOOR"},{"number":"558322","date":"2014-08-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REMOVE & RELOCATE 7-EXISTING 2X4 LAY IN FLUUR LGT FIX , INSTALL 7- OCCUP SENSORS IN WALL, RELOCATE 2-EXIST SINGLE POLE SW, INSTALL 5-DUPLES RECPT & 2 QUAD RECPT ON EXIST CKTS AS PER NEC 2008 (OFFICE BLDG)"},{"number":"557717","date":"2014-08-28","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-04-28","scope":"INTERIOR DEMOLITION OF NON-BEARING PARTITIONS ON 27TH FLOOR ONLY."},{"number":"560878","date":"2014-09-10","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"RELOCATE 8 SPRINKLER HEADS (COMMERCIAL)"},{"number":"556165","date":"2014-09-15","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-04-24","scope":"FURNISH AND INSTALL LIGHTING AND POWER THROUGH OUT OFFICE SPACE AS PER 2008 NEC (CC DISTRICT)"},{"number":"559695","date":"2014-09-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"REPLACEMENT OF (9) WATER CLOSETS, (10)LAVATORIES (2)URINALS"},{"number":"562316","date":"2014-09-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"RELOCATING 16 SPRINKLER HEADS"},{"number":"562317","date":"2014-09-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-01-21","scope":"RELOCATING 2 SPRINKLER HEADS"},{"number":"563448","date":"2014-09-23","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2014-12-17","scope":"RELOCATION OF 2 SPRINKLER HEADS ON 16TH FLOOR (COMMERCIAL)"},{"number":"559355","date":"2014-09-24","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"FOR LEVEL II ALTERATIONS AT EXIST. OFFICE SPACE FOR RENOVATIONS TO TOILET ROOM AREAS; WORK AREA IS FULLY SPRINKLERED. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, & PLUMBING WORK."},{"number":"558227","date":"2014-09-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-10-13","scope":"INSTALL LOW VOLTAGE CABLING FOR VOICE AND DATA.INSTALL RACKS AND TERMINATION HARDWARE IN IDF'S PER 2008 NEC (OFFICE SPACE)"},{"number":"564300","date":"2014-09-26","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"RELOCATE 4 DIFFUSERS"},{"number":"566090","date":"2014-10-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RUNNING WIR AND INSTALLING OUTLET FOR SANDWICH MAKER BY FRONT COUNTER AREA AS PER 20085 NEC (CC DISTRICT)"},{"number":"561385","date":"2014-10-08","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"FOR LEVEL II ALTERATIONS TO SUITE 2701 OF AN EXISTING BUILDING, ALTERATIONS TO INCLUDE THE DEMOLITION/ERECTION OF PARITION WALLS, PROVIDE FINSIHES AND APPLIANCES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED.SEPARATE PERMTIS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK."},{"number":"566869","date":"2014-10-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REPLACING EXISTING FIXTURES 8 PER 2008 NEC (OFFICE SPACE)"},{"number":"560438","date":"2014-10-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-05","scope":"INSTALL FIRE ALARM DEVICES AS PER NEC 2008 & NFPA 72 (OFFICE BLDG)"},{"number":"568210","date":"2014-10-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2014-11-21","scope":"FOR LEVEL II ALTERATIONS TO EXISTING MECHANICAL SYSTEM, ALTERATIONS TO INCLUDE THE INSTALLATION OF REGISTERS, DIFFUSERS AND MECHANICAL EQUIPMENT WITH ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ELECTRICAL AND PLUMBING WORK."},{"number":"564654","date":"2014-11-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-01-07","scope":"INSTALL NEW 112 KVA TRANSFORMER, 3 PANELS, RELOCATE 25 2X4'S, 80 NEW RECEPTACLES, 6 MOTION SENSORS AND RELOCATE 3 EXITS AS PER 2008 NEC (CC DISTRICT)"},{"number":"571861","date":"2014-11-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2014-12-18","scope":"INSTALL VOICE AND DATA CABLE CAT5E NON-PLENUM RATED WITH A LONGEST RUN OF 450FT FROM WORK STATION TO I.T. ROOM AS PER 2008 NEC (CC DISTRICT)"},{"number":"568271","date":"2014-11-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RENOVATION TO EXISTING SPACE FOR NEW TENANT. INSTALL 13 SPEAKER/STROBES, 1 PANEL & 2 NEW ADDRESS MODULES AS PER NFPA72 (CC DISTRICT)"},{"number":"580782","date":"2015-01-15","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2015-01-15","scope":"FOR THE INSTALLATION OF ONE ACCESSORY ILLUMINATED FLAT WALL SIGN ACCESSORY TO A PREVIOUSLY APPROVED USE AS MEDICAL OFFICE."},{"number":"586384","date":"2015-02-04","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-10-13","scope":"LEVEL II ALTERATION AS PER PLAN."},{"number":"584912","date":"2015-02-05","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2015-03-07","scope":"NEW FLAT WALL SIGN"},{"number":"588472","date":"2015-02-09","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-07-19","scope":"8,500 SQUARE FEET, INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILINGS ONLY. NO OTHER WORK ALLOWED UNDER THIS PERMIT. SEPARATE PERMITS REQUIRED FOR RENOVATION. NO STRUCTURAL CHANGES. MUST MAINTAIN ALL CODE REQUIRED FIRE RATING ON WALL AND FLOOR/CEILING ASSEMBLIES. CALL INSPECTOR PRIOR FOR INITIAL INSPECTION PRIOR TO THE START OF WORK."},{"number":"23354","date":"2015-02-18","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2015-02-18","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 02/18/2016"},{"number":"592908","date":"2015-02-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-10-15","scope":"INSTALL 2 PANTRY SINKS ONE ON EACH FLOOR - WORK WILL COMPLY WITH THE PHHILADELPHIA PLUMBING CODE 2004"},{"number":"593169","date":"2015-02-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-13","scope":"INSTALL 6 2X4 LIGHT FIXTURES, 7 DOWNLIGHTS & 1 EXIT SIGN. NO NEW WIRING."},{"number":"593909","date":"2015-03-04","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-09-24","scope":"RELOCATE THREE DIFFUSERS EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"595376","date":"2015-03-11","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-04-22","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"597647","date":"2015-03-23","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-05-21","scope":"ADD 14 RECEPTACLES,2 SWS,2 OCCUPANCY SENSORS CEILING,6 WALL SENSORS,RELAMP EXISTING 2X4'S AND DOWN LIGHTS.RELOCATE AND RE-CIRCUIT LIGHTING FOR NEW LAYOUT PER 2008 NEC (OFFICE SPACE)"},{"number":"598760","date":"2015-03-30","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-05-01","scope":"FURNISH AND INSTALL 1 KITCHEN SINK - CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC WATER (ALL WORK TO COMPLY WITH 2004 PHILADELPHIA PLUMBING CODE)"},{"number":"595962","date":"2015-03-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-23","scope":"FURNISH AND INSTALL FIRE ALARM DEVICES PER NFPA 72 (OFFICE SPACE)"},{"number":"597085","date":"2015-04-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-05-01","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 26TH FLOOR OF AN EXISTING BUILDING FOR THE USE OF A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF NON BEARING PARTITION WALLS, PROVIDE ACCESSIBILITY IMPROVEMENTS AND FINISHES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"600519","date":"2015-04-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-05-01","scope":"RELOCATE 11-DIFFUSERS AND INSTALL 1-CEILING MOUNTED DUCTLESS EXHAUST FAN. EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"601353","date":"2015-04-08","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-05-01","scope":"RELOCATE 9 EXISTING SPRINKLER HEADS(COMMERCIAL)"},{"number":"607426","date":"2015-05-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REMOVE AND RELOCATE (6) DOWNLIGHTS, 1 FURNITURE FEED AND 5 DUPLEX RECEPTICILES PER 2008 NEC (OFFICE SPACE)"},{"number":"604742","date":"2015-05-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REMOVE AND 2 EXISTING SPEAKER STROBES AND FURNISH AND INSTALL 8 NEW SPEAKER STROBES TO EXISTING CIRCUITS PER NFPA 72(OFFICE SPACE)"},{"number":"615651","date":"2015-06-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-11-13","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 35TH FLOOR OF AN EXISTING BUILDING FOR THE USE OF A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF NON BEARING PARTITION WALLS, PROVIDE ACCESSIBILITY IMPROVEMENTS AND FINISHES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"620835","date":"2015-06-26","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-11-13","scope":"RELOCATE (6) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER ALL NFPA NO. 13 AND LOCAL CODES."},{"number":"620939","date":"2015-06-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-13","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"621276","date":"2015-06-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-10-28","scope":"INSTALL (16) DUPLEX RECEPTACLES (2) FLOOR BOXES. RELOCATE (10) 2X4 FIXTURES.REPLACE EXISTING LIGHTS WITH NEW DOWNLIGHTS. INSTALL (1) EXIT SIGN. REMOVE AND REINSTALL (2) SPEAKER STROBES FOR WALL/CEILING REPLACEMENT AS PER 2008 NEC. (CC DISTRICT)"},{"number":"619792","date":"2015-07-09","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-12-09","scope":"TENANT IMPROVEMENTS PER PLANS. SEE AP #622652 FOR ALTERATIONS TO HVAC SYSTEM. HVAC PLANS INCLUDED WITH FIT-OUT PLANS UNDER THIS AP."},{"number":"622652","date":"2015-07-09","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-09","scope":"ALTERATIONS TO HVAC AS PART OF GROUND FLOOR TENANT IMPROVEMENT. SEE TENANT ALTERATION PERMIT #619792 FOR MECHANICAL PLANS."},{"number":"623050","date":"2015-07-15","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-11-05","scope":"WE WILL BE RELOCATING (30) SPRINKLERS IN THE SANTANDER TRAINER CENTER ON THE 1ST FLOOR"},{"number":"629252","date":"2015-08-03","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2016-04-08","scope":"INERIOR DEMOLITION AS PER EZ STANDARDS"},{"number":"623791","date":"2015-08-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-21","scope":"INSTALL 39-RECEPTS, 5-SWITCHES, 13-2X4 LGTS FIXTURES, 17-RECESSED FIXTURES & 7-RELOCATED LGTS FIXTURES AS PER NEC 2008 & RELOCATE 6-EXIST FIRE ALARM DEVICES IN KIND NO ADD'L DEVICES TO EXIST SYSTEM AS PER NFPA 72 (CC DISTRICT)"},{"number":"624035","date":"2015-08-06","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-09","scope":"FOR THE INSTALLATION OF VAV'S, REGISTERS/DIFFUSERS, SUPPLY/EXHAUST DUCTWORK, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL AND PLUMBING WORK."},{"number":"630425","date":"2015-08-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-12-08","scope":"RELOCATING 25 SPRINKLERS IN THE SAUL EWING SPACE ON THE 38TH FLOOR OF CENTRE SQUARE"},{"number":"631054","date":"2015-08-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-12-18","scope":"INSTALLATION OF 2- SHOWER STALLS, 2- FLOOR DRAINS WITH TRAP PRIMERS, W- WATER CLOSETS, 2- LAVATORIES"},{"number":"631628","date":"2015-08-12","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2015-11-21","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"625025","date":"2015-08-20","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-11-09","scope":"INSTALL 2-NEW RESTROOMS, PANTRY SINK, WATER HEATER, MOP SINK & BOOSTER PUMP THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"624428","date":"2015-08-20","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REWIRE EXISTING LAY-IN LIGHT FIXTURES INSTALL (4) TRACK LIGHTS RELOCATE EXISTING SWITCHES REWIRE RECESSED LIGHTS INSTALL (3) EMERGENCY LIGHTS REWIRE EXISTING RECEPTACLES INSTALL (8) NEW RECEPTACLES ADD (2) SMOKE DETECTORS AND (1) CEILING MOUNTED HORN STROBE TO EXISTING FIRE ALARM SYSTEM AS PER 2008 NEC AND NFPA 72 (CC DISTRICT)"},{"number":"630190","date":"2015-08-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-07-02","scope":"INTERIOR ALTERATIONS/RENOVATIONS TO EXISTING RETAIL SPACE, SCOPE OF WORK TO INCLUDE BUT NOT LIMITED TO NEW SEATING, FINISHES, CASEWORK, AND LIGHTING UPGRADES. NO CHANGES IN USE-OCCUPANCY. ADD'L PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKELRS IF MODIFIED"},{"number":"630752","date":"2015-08-24","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-18","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO INCLUDE DUCTWORK AND MECHANICAL EQUIPMENT AND EIGHTEEN (18) REGISTERS/DIFFUSERS AS PER APPROVED PLANS."},{"number":"633882","date":"2015-08-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-23","scope":"INSTALL 39- PLENUM CAT6 CABLES WITH LONGERST BEING 205 FT INTO EXISTING RACK INSTALL 3- NEW CATEGORY 6 PATCH PANELS TO SUPPORT NEW CABLING... IN ACCORDANCE WITH 2008 NEC"},{"number":"630121","date":"2015-08-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-11-04","scope":"PROVIDE POWER TO (1) CHILLER UNIT (2) NEW POINT OF SALES LOCATIONS AND (1) VIZZIO LOCATION. INSTALL AND CONNECT (1) NEW LIGHT FIXTURE. RELOCATE (4) TELE/DATA LOCATIONS FOR POS AS PER 2008 NEC (NORTH DISTRICT)"},{"number":"636903","date":"2015-09-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL CABLE AND DEVICES FOR 5 DOORS. TIE INTO EXISTING FA CONTROL CIRCUIT AS PER 2008 NEC (CC DISTRICT)"},{"number":"629836","date":"2015-09-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 15 SPEAKER STROBES, 2 SPEAKERS AND 1 NAC PANELAS PER NFPA72 (CC DISTRICT)"},{"number":"630455","date":"2015-09-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-12-18","scope":"LEVEL II ALTERATIONS AS PER PLAN."},{"number":"638717","date":"2015-09-15","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2016-06-30","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"631914","date":"2015-09-17","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-01-09","scope":"FURNISH & INSTALL 10-HI-HATS, 18-2X2 LIGHTS, 9-DUPLEX RECEPTS, 4-EXITS, REMOVE & RELOCATE 19-2X2 LIGHTS AS PER NEC 2008 OFFICE BLDG CC DISTRICT"},{"number":"637912","date":"2015-09-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-08","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND MECHANICAL EQUIPMENT WITH ASSOCIATED DUCTWORK IN AN CHILD CARE OCCUPANCY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"637355","date":"2015-09-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-12-21","scope":"INTERIOR ALTERATIONS, UPGRADES, RENOVATIONS TO OFFICE FLOOR AREA AS PER PLANS. ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS."},{"number":"640699","date":"2015-09-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"ELECTRICAL SAFE OFF, INSTALL 3 TEMP GFCI RECEPTS FOR DEMO FOR ONE MONTH AS PER 2008 NEC (CC DISTRICT)"},{"number":"635602","date":"2015-09-23","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-03-24","scope":"INTERIOR RENOVATIONS/ALTERATIONS TO EXISTING OFFICE AND LOBBY FLOOR LEVELS, UPGRADES TO COMMUNICATING STAIRS AND BATHROOMS INCLUDING, DRYWALL, CEILING, FLOOR TILE,RAILS, FINISHES, ALL AS PER PLANS. NO CHANGE IN USE OR OCCUPANCY. ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS."},{"number":"642666","date":"2015-10-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-29","scope":"REMOVE & REPLACE 88-2X4 LIGHT FIXTURES - ONE FOR ONE LIGHT FIXTURES REPLACEMENT NO NEW WIRING FIXTURES -REPLACEMENT ONLY AS PER NEC 2008 CC DISTRICT"},{"number":"23794","date":"2015-10-07","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2015-10-07","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 10/7/2016"},{"number":"645639","date":"2015-10-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"ONE FOR ONE SWAP OF ACCESS PANELS AND READERS: 30TH FLOOR COPY AREA, 31ST FLOOR VOICE/DATA ROOM PER 2008 NEC (OFFICE SPACE)"},{"number":"648221","date":"2015-10-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-01-09","scope":"REMOVE & RELOCATE 2-EXISTING STROBES (ONLY) AS PER NFPA 72 CC DISTRICT"},{"number":"643884","date":"2015-10-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-01-11","scope":"INTERIOR ALTERATIONS, SELECTIVE DEMO OF INTERIOR PARTITIONS, NEW PARTITIONS,CEILINGS, RECONFIGURATION OF FLOOR SPACE, NEW WINDOWS, DOORS, UPGRADES TO FINISHES, AS INDICATED PER PLANS. SEPARATE MEPS PERMITS REQUIRED."},{"number":"649552","date":"2015-11-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2015-12-22","scope":"RELOCATE 15 DIFFUSERS AND 1 VAV BOX. ** EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"649994","date":"2015-11-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-18","scope":"RELOCATE 411 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"649505","date":"2015-11-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"TELECOM- 20- RUNS OF CAT5 CABLE AND 20 STATION RECEPTACLES...... IN ACCORDANCE WITH 2008 NEC"},{"number":"650402","date":"2015-11-06","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2015-11-06","scope":"FOR USE AS A GROUP DAYCARE CENTER IN AN EXISTING STRUCTURE WITH ALL OTHER USES AS PREVIOUSLY APPROVED."},{"number":"620848","date":"2015-11-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-04-08","scope":"PARTIAL CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS TO INCLUDE FIT OUT, STRUCTURAL WORK, UPGRADES TO FINISHES, ADA UPGRADES, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE SUPPRESSION WORK."},{"number":"641796","date":"2015-11-09","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-04-08","scope":"SANITARY & DOMESTIC PIPING PER PLANS. CONNECTIONS TO EXISTING PIPING. FIXTURES AS FOLOWS 17WC, 23 LAV, 22 SINKS, 5 FLOOR DRAINS THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"651603","date":"2015-11-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-01-08","scope":"NO NEW WIRING FISHING ONLY - RELOCATE 10 FIXTURES FURNISH AND INSTALL 3 NEW FIXTURES ADD 1 EXIT ADD 3 WALL SENSOR 4 RECEPTICLES 2 FURNITURE FEEDS 1 EXHAUST FAN CONNECTION ALL NEW DEVICES CONNECT TO EXISTING CIRCUITS AS PER 2008 NEC (CC DISTRICT)"},{"number":"651640","date":"2015-11-12","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2015-12-22","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"651917","date":"2015-11-13","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-04-08","scope":"RELOCATE (205) SPRINKLER HEADS TO ACCOMDATE NEW WALL/CEILING LAYOUTS"},{"number":"652176","date":"2015-11-18","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2015-12-22","scope":"REMOVE OLD PANTRY SINK, INSTALL NEW. INSTALL POINT OF USE WATER HEATER"},{"number":"652943","date":"2015-11-18","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2015-11-18","scope":"RETAIL SALE OF FOOD, BEVERAGES, AND GROCERY IN SUITE # 38"},{"number":"649437","date":"2015-11-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-03-21","scope":"NEW CEILING GRID AND TILES. NEW LIGHTS. RELOCATE DOORWAY AS PER PLAN. **PERMIT TO COMPLY WITH VIOLATION# 510767**"},{"number":"653579","date":"2015-12-02","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-21","scope":"INSTALL MOP SINK, HAND SINK AND KITCHEN SINK, INSTALL 30- GALLON WATER HEATER, EXTEND FROM EXISTING SANITARY, VENT AND COLD WATER"},{"number":"655756","date":"2015-12-03","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-21","scope":"RELOCATING 7 SPRINKLOERS IN THE NUTS TO YOU SPACE ON THE 1ST FLOOR"},{"number":"652221","date":"2015-12-07","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-03-18","scope":"MECHANICAL DEMOLITION AND ALTERATIONS, INSTALL NEW DUCTWORK, AIR DEVICES, PUMP, MECHANICAL PIPING, EXHAUST FANS, DUCT HEATERS, RECALIBRATE AND RELOCATE EXISTING VAV BOXES, COMPUTER ROOM CRU'S, ACCOMODATE FLOOR RECONFIGURATION, NEW LAYOUT."},{"number":"657553","date":"2015-12-11","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-02-19","scope":"RELOCATE (20) SPRINKLER HEADS TO ACCOMMODATE TENANTS LAYOUT AS PER NFPA NO. 13 AND LOCAL CODES."},{"number":"657020","date":"2015-12-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-18","scope":"PANTRY SINK INSTALLATIONS - ONE SINK ON THE CONCOURSE LEVEL WITH A PUMPED WASTE, (3)SINKS ON THE 33RD FLOOR AND (4)SINKS ON THE 34TH FLOOR - NOTE: ALL WATER SUPPLIES TO EQUIPMENT (DISHWASHER, ICE MAKER, COFFEE MAKER, ETC.) MUST BE PROTECTED INDIVIDUALLY BY A BACKFLOW ISOLATION DEVICE COMPLYING WITH SECTION P-806.1.1 OF THE PHILADELPHIA PLUMBING CODE AND TABLE 608.1 OF THE 2009 INTERNATIONAL PLUMBING CODE"},{"number":"655000","date":"2015-12-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-03-18","scope":"HVAC, INCLUDED DUCTWORK AND MECHANICAL EQUIPMENT, AS PER PLANS. 7 REGISTERS/DIFFUSERS"},{"number":"660388","date":"2015-12-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-12","scope":"INSTALL 2- KITCHEN SINKS, 2- POINT OF USE WATER HEATERS, EXTEND FROM EXISTING SANITARY, VENT AND COLD WATER"},{"number":"661334","date":"2016-01-04","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-12","scope":"RELOCATE 116 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"656575","date":"2016-01-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-08","scope":"FURNISH AND INSTALL (62) WORK AREA OUTLETS CLASSROOMS CONSITING OF PLENUM RATED CAT6 TELECOMMUNICATION CABLES WITH A RUN OF ABOUT 225. INSTALL CUSTOMER PROVIDE TELECOM EQUIPMENT FOR FITOUT IN TELCOMMUNICATION ROOM AS PER 2008 NEC (CC DISTRICT)"},{"number":"655689","date":"2016-01-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"RELOCATE (6) 2 X 4'S, (1) NEW WALL FIXTURE. (2) HVAC POWER, (3) DUPLEX RECEPTACLES. ALL CONNECTION TO EXIST 100 AMP PANEL IN SPACE AS PER 2008 NEC (CC DISTRICT)"},{"number":"651161","date":"2016-01-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-08","scope":"190-DUPLEX, 2-TRANSFORMERS, 4-PANELS, 11-VAV CONNECTIONS, 200-LIGHT FIXTURES, 30-LIGHT SENSORS AS PER NEC 2008 & FIRE ALARM 37-SPEAKER STROBE, 1-PULL STATION, 2-EXTENDER PANELS & 11-MODULES AS PER NFPA 72"},{"number":"656161","date":"2016-01-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-27","scope":"ELECTRICAL WORK FOR A TENANT FITOUT PROJECT FIXTURES, RECEPTACLES & WIRING AS PER DRAWINGS BY HPE ENGINEERS AND THE 2008 NEC CC DISTRICT & FIRE ALARM DEVICES, STROBES & ETC AS PER NFPA 72, ALSO INSTALLING SECURITY DEVICES AND EQUIPMENT.AS PER 2008 NEC. (CENTER CITY DISTRICT)"},{"number":"658892","date":"2016-01-12","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-03-14","scope":"OFFICE FIT OUT OF 23RD FLOOR EXISTING SHELL SPACE"},{"number":"660665","date":"2016-01-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-03-12","scope":"HVAC INSTALLATION INCLUDING DUCTWORK, HEATING COILS AND EXHAUST FANS, AS PER PLANS."},{"number":"658267","date":"2016-01-19","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-08-15","scope":"FOR THE RELOCATION OF SEVENTEEN (17) SPRINKLER HEADS AND THE EXPANSION OF AN EXISTING FIRE SUPPRESSION SYSTEM IN AN EXISTING OFFICE BUILDING (THIRTY-TWO (32) NEW SPRINKLERS). SPRINKLERS TO BE SERVICED VIA EXISTING"},{"number":"23981","date":"2016-01-19","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2016-01-19","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 1/19/2017"},{"number":"664453","date":"2016-01-19","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-04-12","scope":"RELOCATE (3) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"657255","date":"2016-01-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-08-17","scope":"INSTALL 63 CATEGORY 6 PLENUM CABLES ON CONCOURSE LEVEL, 276 CATEGORY 6 PLENUM CABLES ON THE 33RD FL. AND 342 CATEGORY 6 PLENUM CABLES ON THE 34TH FL. AVERAGE CABLE PULL 165 FEET PER 2008 NEC (OFFICE SPACE)CC DISTRICT"},{"number":"666475","date":"2016-01-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-03-29","scope":"RELOCATE 8 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"660984","date":"2016-02-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-04-14","scope":"FURNISH AND INSTALL POWER,LIGHTING AND LIGHTING CONTROLS PER 2008 NEC (OFFICE SPACE)CC DISTRICT"},{"number":"668207","date":"2016-02-05","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-05-19","scope":"INSTALL (1) COMPOSITE WIRE TO (3) DOORS FOR CARD ACCESS SYSTEM AS PER 2008 NEC (CC DISTRICT)"},{"number":"665783","date":"2016-02-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2016-03-29","scope":"LEVEL II ALTERATION INCLUDES OF NON BEARING WALLS FOR TOILET ROOMS AS PER PLAN. **SEPARATE PERMITS REQUIRED FOR MEP WORK**"},{"number":"660197","date":"2016-02-10","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL COMPOSET CABLE FOR CARD READER LONGEST RUN 100\" AS PER 2008 NEC (CC DISTRICT)"},{"number":"669542","date":"2016-02-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-03-29","scope":"RELOCATE SIX (6) DIFFUSERS, EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"663475","date":"2016-02-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-16","scope":"FURNISH AND INSTALL 668 CATEGORY 6A PLENUM RATED DATA CABLES WITH LONGEST RUN BEING 285FT. FURNISH AND INSTALL 28 CATEGORY 6A PATCH PANELS TO SUPPORT NEW CABLING. FAI PLENUM 50 PAIR COPPER RISER TO PENN IDF ON 10TH FLOOR. FAI 1 PLENUM 24 STRAND SINGLE MODE FIBER CABLE TO PENN IDF ON MEZZANINE. FAI ALL NECESSARY SUPPORTS AS PER CODE 2008"},{"number":"668060","date":"2016-02-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (8) 2X4'S, (8) DOWNLIGHTS & (4) SWITCHES. BY FISHING AS PER 2008 NEC (CC DISTRICT)"},{"number":"671646","date":"2016-02-24","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2016-06-11","scope":"INTERIOR DEMO OF NON LOAD BEARING PARTITIONS ONLY (COMMERCIAL)"},{"number":"671066","date":"2016-02-25","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-03-29","scope":"REPLACEMENT OF: 12- WATER CLOSETS, 10- LAVATORIES, 2- URINALS. INSTALL TWO ADA BATHROOMS: 2- WATER CLOSETS, 2- LAVATORIES, SOIL, VENT AND DOMESTIC WATER"},{"number":"664460","date":"2016-02-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL SPEAKER SPEAKER STROBES, PULL STATIONS AND FIRE ALARM DEVICES AS PER NFPA72"},{"number":"667229","date":"2016-03-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-23","scope":"INSTALL CUSTOM PROVIDED AV EQUIPMENT, NEW TV AND MOUNTS. CONTROL CABLING AND SPEAKERS FOR CONFERENCE ROOMS,ALL CABLING IS PLENUM RATED AND LONGEST CABLE RUN IN 75FT,CABLING IS 10-HDMI,6-VGA AND 12-RJ45 TO RJ45 CATEGORY PATCH CABLES AS PER 2008 NEC (CC DISTRICT)"},{"number":"676717","date":"2016-03-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-08-09","scope":"THISIS AN OVER THE COUNTER PERMIT APPLICATION. WE WILL BE RELOCATING (6) SPRINKLER ON THE 30TH FLOOR WEST TOWER.EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"672469","date":"2016-03-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 1-CARD ACESS PANEL & ACCESS CONTROL DOORS AS PER NEC 2008 CC DISTRICT"},{"number":"672211","date":"2016-04-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 4 STROBES PER NFPA 72 (OFFICE SPACE)CC DISTRICT"},{"number":"683477","date":"2016-04-12","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL TEMPORARY LIGHTS & WIRE - FROM EXISTING SERVICE, 120V PANEL 2-TEMPORARY STRINGER PER FLOOR FROM 4/18/16 TO 10/18/16 AS PER NEC 2008 CC DISTRICT"},{"number":"683241","date":"2016-04-12","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2016-06-06","scope":"AMEND PERMIT# 666270 TO REFLECT THE CORRECT ADDRESS FOR LEVEL II ALTERATIONS INCLUDES FIT OUT OF NON-BEARING WALLS AS PER PLAN."},{"number":"684275","date":"2016-04-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-05-10","scope":"REPLACE WITH NO ADDITONAL WIRING WITH IN EXISTING RENOVATED SPACE - RELOCATE 3 LIGHT FIXTURES, 2 LIGHT SWITCHES AND 4 RECEPTACLES AS PER 2008 NEC (CC DISTRICT)"},{"number":"682812","date":"2016-04-20","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"ABANDONED","completedDate":"2016-05-11","scope":"AMEND PERMIT NUMBER 620848. FOR THE CONSTRUCTION OF GWB FIRE RATED ASSEMBLY IN SELECT AREAS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE SUPPRESSION WORK. NO STRUCTURAL WORK ON THIS PERMIT."},{"number":"687783","date":"2016-04-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-06-06","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"698530","date":"2016-06-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2016-10-14","scope":"INSTALL TEMP LIGHTS AND RECPTACLES ON EXISTING PANEL AS PER 2008 NEC (CC DISTTRICT)"},{"number":"699720","date":"2016-06-15","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2016-07-08","scope":"INTERIOR DEMO OF NON LOAD BEARING PARTITIONS ONLY. (COMMERCIAL)"},{"number":"698916","date":"2016-06-22","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-04-05","scope":"LEVEL II ALTERATION INCLUDES OF NON BEARING WALLS FOR OFFICE SPACE AS PER APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR MEP WORK**"},{"number":"701581","date":"2016-06-30","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2016-09-29","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK TO THE 27TH/28TH FLOOR OF AN EXISTING BUILDING FOR USE AS A BUSINESS OCCUPANCY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ELECTRICAL AND PLUMBING WORK."},{"number":"704201","date":"2016-06-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2016-09-29","scope":"RELOCATE (214) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"707095","date":"2016-07-13","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"EXPIRED","completedDate":null,"scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"700930","date":"2016-07-15","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-08-01","scope":"FOR INTERIOR LEVEL 2 ALTERATIONS TO FLOORS 15 THROUGH 20 OF AN EXISTING HIGHRISE BUILDING. ALTERATIONS TO INCLUDE FIT-OUT FOR NEW OFFICE SPACES AND NEW STAIRWAY CONNECTING THE 18TH AND 19TH FLOOR. DRAFT CURTAIN REQUIRED AS PER 708.2 OF THE 2009 IBC. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"707669","date":"2016-07-26","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":null,"scope":"LEVEL II ALTERATION INCLUDES NEW WALL FOR NEW HVAC UNIT AS PER PLAN."},{"number":"710245","date":"2016-07-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-09-29","scope":"REMOVE AND REPLACEMENT ONLY: 8- WATER CLOSETS, 12- LAVATORIES, 3- URINALS AND 2- FLOOR DRAINS (NO OTHER FIXTURES ON THIS PERMIT"},{"number":"710270","date":"2016-07-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-09-29","scope":"REMOVE 4- PANTRIES, INSTALL 5- NEW PANTRIES WITH NEW ROUGH-INS. NO OTHER FIXTURES ON THIS PERMIT"},{"number":"707791","date":"2016-07-27","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-01","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND MECHANICAL APLICANCES WITH ASSOCIATED DUCTWORK THROUGHOUT AN EXISTING BUILDING FROM THE 15TH THROUGH THE 20TH FLOOR. MECHANICAL APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ELECTRICAL AND PLUMBING WORK."},{"number":"702971","date":"2016-08-02","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"NEW LIGHTING, SWITCHES, RECEPTACLES, PANELS, TRANSFORMER, FEEDERS, HVAC WIRING & COMMUNICATION OUTLET BOXES (EXCLUDING CABLE & JACKS) AS PER 2008 & FIRE ALARM DEVICES ON EXISTING PANEL AS PER NFPA 72 CC DISTRICT"},{"number":"712250","date":"2016-08-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-02-10","scope":"FOR LEVEL II ALTERATIONS TO THE TOILET ROOMS ON THE UPPER MEZZANINE, 9TH FLR, 10TH FLR AND 11TH FLR AND THE RECEPTION AREA ON THE 9TH FLR. NO STRUCTURAL WORK ON THIS APPLICATION. NO CHANGE IN PREVIOUSLY APPROVED OCCUPANCY AND OCCUPANT LOAD. **SEPARATE PERMITS REQUIRED FOR MEP WORK**"},{"number":"706680","date":"2016-08-16","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-08-01","scope":"RELOCATE 842 EXISTING SPRINKLERS HEADS (COMMERCIAL)"},{"number":"709033","date":"2016-08-23","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-08-01","scope":"ALTERATION: INTERIOR PLUMBING FOR AN TENANT FIT-OUT (BUSINESS OFFICE) OF FLOORS 15 THOUGH 20, IN THE WEST TOWER OF A HIGH RISE BUILDING. THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUMBING CODE, 2004.REFER TO BP #700930."},{"number":"717565","date":"2016-08-25","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-02-08","scope":"RELOCATE 32 SPRINKLERS ON THE UPHS CENTER SQUARE RESTROOM AND OFFICE -EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"709229","date":"2016-08-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-01","scope":"INSTALL NEW PANELS, RECEPTS, POKE THRUS AND LIGHTING AS PER 2008 NEC (CC DISTRICT) NO FIRE ON THIS PERMIT"},{"number":"716186","date":"2016-09-01","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-02-08","scope":"FOR THE INSTALLATION OF A NEW MECHANICAL SYSTEM IN AN EXISTING OFFICE BUILDING. WORK TO INCLUDE REGISTERS/DIFFUSERS, EXHAUSTS, AND ALL SUPPLEMENTAL DUCTWORK AS SHOWN IN APPROVED PLANS."},{"number":"713467","date":"2016-09-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-26","scope":"FURNISH & INSTALL NAC PANELS, SPEAKERS/STROBES AND STROBES THROUGHOUT PER PLAN AND PER SPACE."},{"number":"712093","date":"2016-09-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-03-29","scope":"FOR ALTERATIONS TO AN EXISTING FIRE SUPPRESSION SYSTEM WITH THE INSTALLATION OF A NEW SINGLE INTERLOCK PRE-ACTION SPRINKLER SYSTEM TO CONNECT TO EXISTING SYSTEM IN ACCORDANCE WITH NFPA 2007, STANDARD 13. (SEPARATE RELOCATE PERMIT WAS PULLED, #704201)"},{"number":"721846","date":"2016-09-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-04-06","scope":"RELOCATE 1 SPRINKLER HEAD IN THE 20TH FLOOR BATHROOM"},{"number":"705361","date":"2016-09-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL (1116) CATEGORY 6A PLENUM CABLES.INSTALL (1681) CATEGORY 6 PLENUM CABLES. AVG CABLE PULL 170. AS PER 2008 NEC. (CC DISTRICT)"},{"number":"705359","date":"2016-09-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-03-14","scope":"INSTALL (681) CATEGORY 6 PLENUM CABLES. AVG CABLE PULL 150 FEET.AS PER 2008 NEC (CC DISTRICT)"},{"number":"716168","date":"2016-09-22","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-02-08","scope":"ALTERATION: INTERIOR PLUMBING FOR TOILET ROOMS ON THE MEZZANINE, 8TH, 10TH AND 11TH FLOORS OF A HIGH RISE BUILDING. THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004."},{"number":"716224","date":"2016-09-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL DOWNLIGHTS, LINEAR FIXTURES, GFI RECEPTACLES, POWER TO HAND DRYERS, FURNITURE FEEDS AND LIGHTING CONTROLS AS PER PLANS AND SPECS IN ACCORDANCE WITH 2008 NEC (OFFICE SPACE)CC DISTRICT"},{"number":"724847","date":"2016-10-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-07-11","scope":"PERMIT TO RECONFIGURE EXISTING OFFICE (RECEPTION) AREA, AS PER PLANS."},{"number":"720533","date":"2016-10-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-31","scope":"INSTALL SECURITY DEVICES AND LOW VOLTAGE COMPOSITE ABLING AS PER PLANS. AS PER 2008 NEC. (CC DISTRICT)"},{"number":"721556","date":"2016-10-13","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-02-15","scope":"FURNISH AND INSTALL 4 SPEAKER STROBES AND 19 SROBES AS PER NFPA72"},{"number":"732480","date":"2016-10-28","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"EXPIRED","completedDate":null,"scope":"RELOCATING 6 SPRINKLERS ON 31ST FLOOR"},{"number":"709376","date":"2016-11-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL NEW CATEGORY 6 WIRING TO 34 DUAL LOCATION 41 SINGLE LOCATIONS.INSTALL 2 NEW NETWORK RACKS IN COMMUNICATIONS ROOM. INSTALL NEW SOUND MASKING SYSTEM WITH 38 SPEAKER LOCATIONS ABOVE CEILING.ALL CABLING WILL BE PLENUM RATED CABLE PER 2008 NEC (OFFICE SPACE)"},{"number":"733464","date":"2016-11-10","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-01-24","scope":"FOR LEVEL II ALTERATIONS TO THE LUNCHROOM / KITCHEN ON THE 10TH FLR. NO STRUCTURAL WORK ON THIS APPLICATION. NO CHANGE IN PREVIOUSLY APPROVED OCCUPANCY AND OCCUPANT LOAD. **SEPARATE PERMITS REQUIRED FOR MEP WORK**"},{"number":"733373","date":"2016-11-28","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2017-02-08","scope":"TO AMEND A/P NO 712250 TO DOCUMENT MINOR CHANGES TO PLANS AND FINISHES. A/P NO 712250 WAS ISSUED FOR LEVEL II ALTERATIONS TO THE TOILET ROOMS ON THE UPPER MEZZANINE, 9TH FLR, 10TH FLR AND 11TH FLR AND THE RECEPTION AREA ON THE 9TH FLR. NO STRUCTURAL WORK ON THIS APPLICATION. NO CHANGE IN PREVIOUSLY APPROVED OCCUPANCY AND OCCUPANT LOAD. **SEPARATE PERMITS REQUIRED FOR MEP WORK**"},{"number":"739780","date":"2016-12-01","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2016-12-27","scope":"REPLACEMENT 1- KITCHEN SINK. RELOCATE A KITCHEN SINK TO NEW LOCATION"},{"number":"717499","date":"2016-12-02","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2016-12-02","scope":"FOR THE ERECTION OF A STRUCTURE AROUND AND EXISTING STAIRWAY AND SEMI-DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON APPROVED PLANS. STRUCTURES FOR ACCESS TO 1500S MARKET ST."},{"number":"717501","date":"2016-12-02","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-12-14","scope":"ALTERATIONS TO CONCOURSE AS PER APPROVED PLANS.** ASBESTOS REMOVAL REQUIRED PRIOR TO COMMENCING WORK ** SEPARATE PERMITS REQUIRED FOR ANY M.E.P. WORK."},{"number":"720672","date":"2016-12-02","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-12-14","scope":"ERECTION OF ELEVATOR AND A GLASS ENCLOSURE AROUND EXISTING STEPS. BOTH FOR ACCESS TO CONCOURSE. SEE A/P NO. 717501 FOR APPROVED PLANS. ** ASBESTOS REMOVAL REQUIRED PRIOR TO COMMENCING WORK ** SEPARATE PERMITS REQUIRED FOR ANY M.E.P. WORK."},{"number":"24606","date":"2016-12-02","work":"Operations","type":"OPS PERMIT","description":"OPERATIONS PERMIT","status":"COMPLETED","completedDate":"2016-12-02","scope":"HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES:120217"},{"number":"756580","date":"2017-02-03","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-11","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"757660","date":"2017-02-08","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2017-07-11","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"758126","date":"2017-02-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"FURNISH AND INSTALL APPROXIMATELY 30 CAT 5E PLEMUM CABLES FOR VOICE AND DATA PER 2008 NEC (OFFICE SPACE)"},{"number":"749816","date":"2017-03-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":"2017-06-30","scope":"SELECTIVE DEMOLITION AND RENOVATIONS TO THE 31ST FLOOR. RENVOATIONS INCLUDE MINOR CUT AND PATCHING AT EXISTING PARTITIONS AS PER PLAN."},{"number":"753946","date":"2017-03-13","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-07-11","scope":"NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. SEPARATE PERMITR REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK. PERMIT TO COMPLY WITH VIOLATION CASE NO. 574140"},{"number":"759720","date":"2017-03-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-14","scope":"ELECTRICAL WORK INCLUDING RELOCATING 20-LIGHTS,8-NEW LIGHT FIXTURES,8-SWITCHES AND 16-RECEPTS AS PER 2008 NEC (CC DISTRICT) INSTALL 3-STROBES TO THE FIRE ALARM SYSTEM AS PER NFPA72"},{"number":"765125","date":"2017-03-23","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-12-14","scope":"MODIFICATIONS TO AN EXISTING FIRE SUPPRESSION SYSTEM AND FOR THE INSTALLATION OF NEW SPRINKLER HEADS AS PER NFPA 13 IN NEW ELEVATOR PITS AND MACHINE ROOMS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL AND PLUMBING WORK."},{"number":"762110","date":"2017-04-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 75 DUAL CATEGORY 6 PLENUM CABLES FROM 30TH FLOOR IDF TO LOCATION ON 30TH & 31ST FLOOR LONGEST RUN 220' AS PER NEC 2008 CC DISTRICT"},{"number":"776466","date":"2017-04-19","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-11-10","scope":"INSTALL 2\" RPZ BACKFLOW ON WATER MAIN FEED NEW BATHROOM (SEPTA FACILITY)THE INSTALLATION SHALL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004"},{"number":"769567","date":"2017-05-04","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":"2017-12-07","scope":"FOR LEVEL II ALTERATIONS TO THE 30TH AND 31ST FLOOR OF AN EXISITNG BUILDING FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE INSTALLATION OF FINISHES AND FURNISHING THROUGHOUT WITH THE INSTALLATION OF A MOTHERING ROOM IN RESTROOM AREA ON THE 30TH FLOOR LEVEL. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"799865","date":"2017-07-25","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-02-13","scope":"FOR LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) ON 18TH FLOOR OF AN EXISTING OFFICE BUILDING AS PER PLANS, SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS."},{"number":"803541","date":"2017-07-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-23","scope":"REWORK 10 EXISTING LIGHTS AND RELOCATE 4 EXISTING OUTLETS AS PER NEC 2008 CC DISTRICT"},{"number":"803992","date":"2017-07-28","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-02-13","scope":"FURNISH LABOR TO RELOCATE 3 DIFUSSERS"},{"number":"792152","date":"2017-09-28","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2017-09-28","scope":"INSTALL (1) SET OF INTERNALLY ILLUMINATED CHANNEL LETTERS FLAT WALL SIGN 30\"X162\"=33.7SF"},{"number":"819814","date":"2017-10-24","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2017-11-11","scope":"INSTALL 1 SET OF INTERNALLY ILLUMINATED CHANNELS."},{"number":"818006","date":"2017-10-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-17","scope":"SUPPLY POWER FOR NEW SIGN 120V 20AMP CKT WIRING INSIDE TO FEED SIGN OUTSIDE AS PER NEC 2008 CC DISTRICT"},{"number":"830455","date":"2017-11-08","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-01-10","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"843891","date":"2018-01-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-07-31","scope":"RELOCATE 16 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"844057","date":"2018-01-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-02-13","scope":"RELOCATE 11 EXISTING SPRINKLER HEADS (COMMERCIAL)"},{"number":"844287","date":"2018-01-10","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-02","scope":"- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. INTRERIOR DEMO OF NON-BEARING WALLS"},{"number":"845337","date":"2018-01-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-16","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"845762","date":"2018-01-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-06-16","scope":"THIS IS AN OVER THE COUNTER PERMIT APPLICATION. WE WILL BE RELOCATING (3) SPRINKLERS WITHIN PENN MEDICINE ON THE 23RD FLOOR.FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"844771","date":"2018-01-24","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-06-16","scope":"INTERIOR DEMOLITION AND RENOVATION OF EXISTING OFFICE SPACE."},{"number":"844854","date":"2018-01-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"EXPIRED","completedDate":null,"scope":"FOR THE REPLACEMENT OF COOLING TOWER WITH STRUCTURAL RENOVATIONS TO SUPPORT NEW COOLING TOWER, WORK TO BE COMPLETED ON THE FOLLOWING FLOORS: 41, 42, 43. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.***AMENDED PERMIT REQUIRED FOR SPECIAL INSPECTIONS.***"},{"number":"848845","date":"2018-01-30","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-27","scope":"FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"848847","date":"2018-01-30","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-27","scope":"FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"848848","date":"2018-01-30","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-27","scope":"FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"853714","date":"2018-02-21","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-27","scope":"24TH FLOOR/ WEST TOWER EZ INTERIOR DEMO FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"853717","date":"2018-02-21","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2018-04-16","scope":"26TH FLOOR/ WEST TOWER EZ DEMP PERMIT FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"845983","date":"2018-02-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-09","scope":"NEW ELECTRICAL FEEDERS, DISCONNECTS, AND HEAT TRACE FOR NEW COOLING TOWERS BEING INSTALLED ON THE ROOF AS PER NEC 2008 CC DISTRICT"},{"number":"852763","date":"2018-03-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-05-25","scope":"FOR LEVEL II ALTERATIONS TO THE FIFTH FLOOR LEVEL (SUITE 545) OF AN EXISITNG BUILDING FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE INSTALLATION OF PARTITION WALLS WITH FINISHES AND FURNISHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"849477","date":"2018-03-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-27","scope":"INSTALL RECEPTACLES, LIGHT FIXTURES AND LIGHTING CONTROLS ONLY AS PER NEC 2008 (CC DISTRICT)"},{"number":"857967","date":"2018-03-09","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-05-25","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"859704","date":"2018-03-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-12-17","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. REPLACE TWO (2) 6 TON HEAT PUMP"},{"number":"860701","date":"2018-03-20","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-30","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"857919","date":"2018-03-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-07-10","scope":"LEVEL 2 ALTERATIONS TO RECONFIGURE OFFICE TENANT SPACE WITHIN A PORTION OF THE 24TH FLOOR OF AN EXISTING HIGHRISE BUILDING AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION."},{"number":"862339","date":"2018-03-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-05-21","scope":"RELOCATE EXISTING CIRCUITS FOR FOR NEW OFFICE LAYOUT REPLACE EXISTING LIGHTING WITH NEW PER 2008 NEC (OFFICE SPACE) RELOCATE 2 FIRE ALARM SIGNALING DEVICES *NO ADDITIONAL WIRING* PER NFPA 72"},{"number":"868008","date":"2018-04-18","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-12-05","scope":"INSTALL: 44- CAT6A PLENUM RATED 4- PAIR CABLES, 3- RG6 QUAD SHIELD PLENUM RATED COAX CABLES. LONGEST RUN- 200'.... IN ACCORDANCE WITH 2008 NEC (OFFICE)"},{"number":"867318","date":"2018-04-25","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-16","scope":"FOR MECHANICAL ALTERATIONS TO PARTIAL NINTH FLOOR, TO INCLUDE NEW A/C UNIIT, VAV'S WITH ASSOCIATED DUCTWORK AND REGISTERS/DIFFUSERS, AS PER APPROVED PLANS."},{"number":"866839","date":"2018-04-27","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-06-16","scope":"ALTERATIONS TO PORTIONS OF THE 9TH FLOOR OFFICES TO INCLUDE REMOVAL OF SHELVING AND CEILING EQUIPMENT/DEVICES AND REPAIR OF PARTITIONS IN THOSE LOCATIONS AS PER PLANS."},{"number":"869440","date":"2018-04-27","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-07-10","scope":"PROVIDE 1 KITHCEN SINKS WITH SANITARY AND DOMESTIC PIPING TIED INTO EXISTING RISERS ADD ONE INDIRECT WAIST DRAIN. INSTALLATIONS IN ACCORDANCE WITH 2004 PPC"},{"number":"872412","date":"2018-04-30","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2018-07-10","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"869764","date":"2018-05-01","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-10","scope":"FURNISH AND INSTALL 2 VAV DAMPERS, DUCT, AIR DEVICES, FOR NEW OFFICE LAYOUT AS PER PLAN."},{"number":"866826","date":"2018-05-03","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-25","scope":"INSTALL 90 RECEPTACLES 1-45KVA TRANSFORMER 4 WALL FURNITURE FEEDS 2 FLOOR BOXES 20 MOTION DETECTORS 60 LIGHTS 6 EXIST SIGNS 1 EXHAUST FAN FEED 1-60AMP BREAKER 2 NEW VAV FEEDS RELOCATE 1 VAV FEED"},{"number":"870399","date":"2018-05-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 76- CAT6 PLENUM CABLES - LONGEST RUN, 175'. TERMINATE, TEST AND LABEL ALL NEW CABLING, SUPPORT ALL CABLING. CABLES WILL LAND IN EXISTING RACKS. ALL WORK IN ACCORDANCE WITH 2008 NEC (OFFICE)"},{"number":"873389","date":"2018-05-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-08","scope":"FURNISH AND ISNTALL 10 NEW SPEAKERS,STROBES, 1 MODULE AND 1 NA PANEL PER NFPA 72 (OFFICE SPACE)"},{"number":"867817","date":"2018-05-22","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2018-05-22","scope":"NO CHANGE OTHER THAN THE FOLLOWING 1)EXPANSION OF PORTION OF FIRST FLOOR BUILDING ALONG MARKET ST FTONTAGE TO FRONT PROPERTY LINE AS PER SUBMITTED ARCHITECTURAL AND ZONING PLANS 1)EXPANDED/NEW CONSTRUCTION OF NEWLY CREATED AREA OF 1615 SF TO BE USED FOR RETAIL SALES AND THUS EXEMPT FROM GROSS FLOOR AREA CALCULATIONS PURSUANT TO SRCTION 12-202)(4)(B)(.10); AND 3)ALL SITE PLAN CHANGES ARE AS ATTACHED/SUBMITTED PROPOSED ZONING AN ARCHTECTURAL PLANS (Z-001, Z-002, & Z-003). THIS APPLICATIOM IS FILED WITHOUT PREJUDICE TO , OR ABANDONRMENT OF, ALL PRIOR PERMITS AND APPROVALS."},{"number":"879253","date":"2018-05-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-08-09","scope":"INSTALLING ACCESS CONTROL WIRING AND 20-PLENUM RATED DATA CABLES FOR COMPUTERS WITH A LONGEST RUN OF ABOUT 120FT AS PER 2008 NEC (CC DISTRICT)"},{"number":"872419","date":"2018-05-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-27","scope":"INSTALL RECEPTACLES, PROJECTOR POWER & PROJECTOR SCREEN POWER AS PER 2008 NEC (CC DISTRICT)"},{"number":"868200","date":"2018-07-09","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2018-07-09","scope":"INSTALL 3 ACCESSORY SIGNS TO AN EXISTING NON ACCESSORY GARAGE"},{"number":"906208","date":"2018-09-11","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2018-11-21","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 27TH FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**"},{"number":"911717","date":"2018-09-19","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-11-21","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"911721","date":"2018-09-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-11-21","scope":"INSTALL ONE PANTRY SINK WITH A CEILING MOUNTED 6 GAL HOT WATER HEATER AND REQUIRED PIPE THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"912357","date":"2018-10-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL 28 DEPLEX RECEPTACLES, 1 FLOOR BOX, 3 FURNITURE FEEDS, 35 FIXTURES & 15 SWITCHES AS PER 2008 NEC (CC DISTRICT)"},{"number":"915544","date":"2018-10-03","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2019-01-10","scope":"- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"921911","date":"2018-10-29","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2018-10-29","scope":"FOR A RETAIL SALE OF CONSUMER GOODS AT SPACE# L460 AS PART OF EXISTING STRUCTURE IN THE SAME BUILDING WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION."},{"number":"904169","date":"2018-11-02","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2019-01-17","scope":"THE ERECTION OF ACCESSORY SIGNAGE-ONE (1) NEW FREESTANDING SIGN, ONE (1) NEW FLATWALL SIGN WITH A DIGITAL DISPLAY, AND THE REPLACEMENT OF AN EXISTING FLATWALL SIGN.SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION.SEPARATE PERMIT REQUIRED FOR ELECTRIC.SIGNS ONLY PERMIT."},{"number":"915315","date":"2018-11-02","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-01-09","scope":"FOR DEMOLITION AND INTERIOR LEVEL 2 ALTERATIONS FOR A NEW MERCANTILE USE WITHIN AN EXISTING BUILDING. SCOPE OF WORK WILL INCLUDE PARTIAL DEMOLITION OF EXISTING INTEIOR FIXTURES AND WALLS, AS WLL AS ARCHITECTURAL WORK FOR A NEW \"ROLL\" SHOWROOM. NO ROOF WORK OR EXTERIOR WORK IS ANTICIPATED AS PART OF THIS PROJECT SCOPE."},{"number":"916343","date":"2018-11-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL FIRE ALARM DEVICES 6-SPEAKER STROBES, 1-EXTENDER & 1-RELAY AS PER NFPA 72 CC DISTRICT"},{"number":"915639","date":"2018-11-08","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-11","scope":"INSTALLATION OF 41 CAT 6 PLENUM 4 PAIR 24 AWG CABLES FOR VOICE AND DATE ALL CABLE WILL BE SUPPORTED WITH J HOOKS ALL FIRE RATES WALLS WILL BE SLEEVED AND FIRE STOPPED"},{"number":"929514","date":"2018-11-30","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-04-17","scope":"FOR LEVEL II ALTERATIONS TO THE EXISTING OFFICE ON THE 35TH FLOOR. NO EXTERIOR OR STRUCTURAL WORK ON THIS APPLICATION. **SEPARATE PERMITS REQUIRED FOR PLUM, ELEC, MECH AND FIRE SUPP WORK**"},{"number":"930731","date":"2018-11-30","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-01-09","scope":"REMOVE EXISTING LIGHTING AND REPLACE WITH NEW. REUSE EXISTING WIRING AND CIRCUITRY. INSTALL NEW SWITCHES (3) AND RECEPTACLES (2)... PER 2008 NEC (SHOWROOM)"},{"number":"933088","date":"2018-12-06","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REMOVE AND RECONNECT POWER TO SIGN #1 120V,INSTALL POWER TO SIGN #2,#3 120V POWER FED FROM PANEL \"G\" CIRCUIT #12,#14.LOCATED IN PARKING GARAGE OFFICE.PANEL IS 120/208V 20 CIRCUIT AS PER 2008 NEC (CC DISTRICT)"},{"number":"902033","date":"2018-12-11","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-03-26","scope":"REPLACEEMNT OF RETAIL CURTAIN WALL ALONG MARKET STREET, MODIFICATION OF PLANTERS IN THE PLAZA, AND INTERIOR FINISHED WITHIN THE COMMON SPACES OF THE CONCOURSE, GROUND FLOOR AND MEZZANINE LEVELS OF THE BUILDING AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY M.E.P. AND FIRE SUPPRESSION WORK. AMENDMENT 03/23/2021: AMEND PERMIT TO CHANGE DPRC-SI."},{"number":"935432","date":"2019-01-03","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-04-17","scope":"FOR LEVEL II ALTERATIONS TO THE 24TH FLOOR LEVEL OF AN EXISITNG BUILDING FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE INSTALLATION OF PARTITION WALLS, WITH FINISHES/FURNISHINGS THROUGHOUT AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"939425","date":"2019-01-07","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-03-20","scope":"EZ PERMIT. RELOCATE 14 HEADS OFF OF EXISTING SYSTEM TO ACCOMMODATE NEW LAYOUT PER NFPA 13"},{"number":"940579","date":"2019-01-10","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-20","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"940604","date":"2019-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-03-20","scope":"INSTALL ONE PANTRY SINK WITH A UNDER COUNTER HOT WATER HEATER AND REQUIRED PIPE THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"940687","date":"2019-01-14","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-04-17","scope":"BUSINESS AND PROFESSIONAL OFFICES. 35TH FLOOR. RELOCATION OF 131 SPRINKLER HEADS AND CONVERTING 70 PENDANTS TO UPRIGHTS. 201 HEAD TOTAL RELOCATES."},{"number":"940636","date":"2019-01-28","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-12","scope":"INSTALL NEW OUTLETS, SWITCHES AND LIGHTS AS PER PLANS AND NEC 2008 (CC DIST)"},{"number":"941605","date":"2019-01-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-17","scope":"ELECTRICAL FIT OUT WORK TO ENTAIL INSTALLATION OF APPROXIMATELY 152 RECEPTACLES, 4 FLOOR BOXES, HOOK UP OF 16 MECHANICAL UNITS, 350 LIGHTING FIXTURES, AND 12 EXIT SIGNS AS PER 2008 NEC. (CC DIST)"},{"number":"943451","date":"2019-01-31","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-04-17","scope":"INSTALL 3-PANTRY SINKS, INSTALL 2-UNDER-COUNTER WATER HEATERS, INSTALL 1-ELECTRIC WATER HEATER, INSTALL ALL REQUIRED PIPE, INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"941600","date":"2019-02-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-17","scope":"HVAC,INSTALLATION INCLUDING DUCTWORK, AS PER PLANS. (81)REGISTER/DIFFUSERS"},{"number":"943788","date":"2019-02-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-01-10","scope":"REPLACING EXISTING LIGHT FIXTURES WITH NEW LIGHTS, NEW LIGHTING CONTROL PANELS, RECEPTACLES. ADDITION OF BEAM DETECTORS TO FIRE ALARM SYSTEM. AS PER NEC. FIRE ALARM AS PER NFPA 72."},{"number":"951246","date":"2019-03-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-03-27","scope":"INSTALL NEW FIRE ALARM DEVICES AS PER NFPA 70E AND PLANS PROVIDED. (CC DIST)"},{"number":"951642","date":"2019-03-06","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-05-07","scope":"LEVEL II INTERIOR ALTERATIONS(NO CHANGE OF OCCUPANCY). FOR RENOVATIONS TO OFICE SPACES ON THE 27TH & 28TH FLOORS OF AN EXISTING STRUCTURE (WITH OTHER APPROVED USES)] AS PER APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"948342","date":"2019-03-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-03","scope":"FURNISH AND INSTALL 261 CAT 6 PLENUM CABLE FROM IDF PATCH PANELS TO OUTLET LOCATIONS AVERAGE RUN IS 175' INSTALL DATA RACK IN IDF ROOM AND CAT 6 PANELS PER 2008 NEC"},{"number":"952421","date":"2019-03-13","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-03-26","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMMODATE NEW LOBBY/ATRIUM LAYOUT AS PER APPROVED PLANS."},{"number":"959943","date":"2019-03-22","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-04-24","scope":"INSTALL 4 CAT 6 PLENUM CABLES, AVERAGE RUN 150', ALL PLENUM CABLES WILL BE SUPPORTED WITH CADDY J HOOKS, ALL SLEEVES AND PENETRATIONS WILL BE FIRE STOPPED AS PER 2005 NEC (CC DISTRICT)"},{"number":"960187","date":"2019-03-22","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-05-07","scope":"RELOCATE 14 EXISTING SPRINKLER HEADS"},{"number":"952429","date":"2019-03-26","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2021-10-18","scope":"INSTALL 8 NEW AREA DRAINS TIE IN PIPING TO EXISTING INSTALL NEW ROOF DRAIN TIE IN TO EXISTING EXTEND 2\" WATER LINE FROM EXISTING TO PLAZA LEVEL INSTALL NEW NO FREEZE HOSE BID"},{"number":"955482","date":"2019-03-27","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"FIRE ALARM FIT-OUT WORK TO ENTAIL INSTALLATION OF APPROXIMATELY (26) NOTIFICATION DEVICES; AND (1) POWER SUPPLY AS PER NFPA 72"},{"number":"956657","date":"2019-03-29","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-05-07","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT ON THE 28TH FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS."},{"number":"957690","date":"2019-04-25","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-05-07","scope":"RELOCATE5-LIGHTS, INSTALL 4-NEW LIGHTS, 4-NEW EXIT LIGHTS, 13-RECEPTACLES, 1-OCCUPANCY SENSOR, RELOCATE 3-SWITCHES AS PER NEC 2008 CC DISTRICT AND FIRE ALARM MANUAL PULL STATION AND 2-SPEAKER/STROBES AS PER NFPA 72"},{"number":"972945","date":"2019-05-03","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-03-26","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"962727","date":"2019-05-07","work":"Zoning admin review","type":"ZP_ADMIN","description":"ZONING ADMIN REVIEW","status":"COMPLETED","completedDate":"2019-05-07","scope":"ZONING BOARD OF ADJUSTMENT ADMINISTRATIVELY APPROVED CHANNEL LETTER SIGNAGE AT THE SAMEW LOCATION FROM ALL CAPITAL LETTERS TO LOWER CASE LETTERS, NO CHANGE TO SIGN AREA."},{"number":"977766","date":"2019-06-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 19TH FLOOR OF AN EXISTING BUILDING (EAST TOWER) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**"},{"number":"977279","date":"2019-06-07","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2019-12-09","scope":"INSTALL (1) SET OF INTERNALLY ILLUMINATED CHANNEL LETTERS 189\" X 58 1/4\" = 76 SF"},{"number":"982095","date":"2019-06-11","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2022-03-30","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 32ND FLOOR OF AN EXISTING BUILDING (WEST TOWER) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**"},{"number":"984529","date":"2019-06-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"984641","date":"2019-06-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"INSTALL 2 FIXTURES AND REPLACE ONLY THREE PANTRY SINKS AS PER 2004 PPC"},{"number":"985371","date":"2019-06-17","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"RELOCATE 37 EXISTING SPRINKLER HEADS ON THE 19TH FLOOR TO ACCOMMODATE TENANT LAYOUTS AS ER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"983464","date":"2019-06-18","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-01-07","scope":"FOR LEVEL II ALTERATIONS TO THE 41ST FLOOR LEVEL OF AN EXISITNG BUILDING FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE INSTALLATION OF PARTITION WALLS, WITH FINISHES/FURNISHINGS THROUGHOUT AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"986711","date":"2019-06-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"INSTALL 35 CAT 6 PLENUM RATES 4 PAIR 23AWG CABLES TO LOCATIONS. ALL CABLES TO BE SUPPORTED WITH J HOOKS AND ALL FIRE RATED WALLS WILL BE FIRE STOPPED AS PER 2017 NEC"},{"number":"984167","date":"2019-06-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"INSTALL LIGHTING FIXTURES, RECEPTACLES & POWER AS PER NEC 2017 CC DISTRICT"},{"number":"988187","date":"2019-06-24","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-01-22","scope":"RELOCATE 51 EXISTING SPRINKLER HEADS ON THE 32ND FLOOR TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"985670","date":"2019-06-26","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-07-02","scope":"INSTALL (17) NEW SPEAKER/STROBES AND (6) NEW SPEAKERS."},{"number":"987242","date":"2019-07-09","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-09-23","scope":"FURNISH AND INSTALL 300 LIGHTS EXIT SIGNS, 72 OCC SENSORS, 40 DIMMERS, 1 GROUND BAR, 11 GFI RECEPTACLES, 11 DEDICATED RECEPTACLES, 90 DUPLEX, RECEPTACLES 30 QUADS, 9 FLOOR BOXES, 6 WALL FURNITURE FEEDS AS PER 2008 NEC. (CC DIST)"},{"number":"990680","date":"2019-07-16","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2020-02-25","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 41ST AND 42ND FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**"},{"number":"995191","date":"2019-07-19","work":"Suppression","type":"BP_FIRESUP","description":"SUPPRESSION PERMIT","status":"COMPLETED","completedDate":"2020-02-12","scope":"RELOCATE 25 EXISTING SPRINKLER HEADS"},{"number":"992618","date":"2019-07-22","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-12-03","scope":"FOR THE INSTALLATION OF A MECHANICAL SYSTEM TO INCLUDE REGISTERS/DIFFUSERS, SUPPLY/EXHAUST DUCTWORK, VAVS, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL AND PLUMBING WORK."},{"number":"917928","date":"2019-07-26","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-07-27","scope":"FURNISH AND INSTALL 250KV LOAD BANK AND ASSOCIATED TRANSFER SWITCH"},{"number":"990362","date":"2019-08-07","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"FURNISH AND INSTALL FIRE ALARM DEVICES AS PER DRAWINGS AS PER NFPA 72 (CC DIST)"},{"number":"1000493","date":"2019-08-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-10-09","scope":"INSTALL 150 CAT 6 PLENUM RATED LOW VOLT NETWORK CABLE DROPS AS PER 2017 NEC"},{"number":"999744","date":"2019-08-15","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2020-02-25","scope":"ALTERATIONS: INTERIOR PLUMBING; (NO CHANGE IN OCCUPANCY);BUSINESS & PROFESSIONAL OFFICE; 41ST AND 42ND-THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004"},{"number":"999751","date":"2019-08-15","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-12","scope":"ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUTS ON THE 41ST AND 42ND FLOORS OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS."},{"number":"1006334","date":"2019-09-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-12","scope":"INSTALL 11 DUPLEX REC, 2 FLOOR BOXES, 3 GFI RECEPTACLES, REWORK LIGHTING ADD 4 QUADS, 2 HWH, 2 VAV, 16 FI LIGHTS, 2 FLEM LIGHTS, 13 F2, 6 F3, 11 F4, 1 F5, 6 EXIT LIGHTS, 1 6TD, 2 DIMMERS AND 1 3WAY SWITCH AS PER 2017 NEC (CC DIST)"},{"number":"1002232","date":"2019-09-19","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2020-02-24","scope":"INSTALL 3 NEW FIRE ALARM DEVICES PER NFPA 72"},{"number":"1011933","date":"2019-09-25","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-05-30","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING RESTROOMS ON THE 42ND FLOOR OF AN EXISTING BUILDING (WEST TOWER) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**"},{"number":"1015128","date":"2019-10-01","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Issued","completedDate":null,"scope":"REPLACE LIGHTS IN KIND UTILIZE EXITING POWER FOR SINKS AS PER 2017 NEC"},{"number":"1017014","date":"2019-10-08","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2022-12-12","scope":"RELOCATE 41 EXISTING SPRINKLER HEADS ON THE 23RD FLOOR TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES."},{"number":"1018020","date":"2019-10-16","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2021-05-18","scope":"INSTALLATION OF NEW HVAC SYSTEM FOR RENOVATED OFFICE SPACE ON THE 26TH FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS."},{"number":"1017748","date":"2019-10-21","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2019-11-07","scope":"FOR LEVEL II ALTERATIONS TO THE 26TH FLOOR LEVEL OF AN EXISITNG BUILDING FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE INSTALLATION OF PARTITION WALLS, WITH FINISHES/FURNISHINGS THROUGHOUT AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK."},{"number":"1018736","date":"2019-10-21","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2019-11-07","scope":"FOR THE INSTALLATION OF REGISTERS,DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS.IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"1020128","date":"2019-10-25","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2021-07-12","scope":"FURNISH & INSTALL KITCHEN SINK AND 6 GAL ELEC HOT WATER HEATER 2 FIXTURES AS PER 2004 PPC"},{"number":"1020232","date":"2019-10-31","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2019-11-07","scope":"FURNISH & INSTALL LIGHTS LIGHTING CONTROLS RECEPS AND BRANCH WIRING AS PER DRAWINGS AND IN ACCORDANCE WITH 2017 NEC CC DISTRICT FURNISH & INSTALL 1 FIRE ALARM NAC PANEL 18 SPEAKER STROBES & 1 STROBE AS PER DRAWINGS AND IN ACCORDANCE WITH NFPA 72"},{"number":"1030744","date":"2019-12-13","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2019-12-13","scope":"INSTALL CHANNEL LETTERS ON EXISTING SIGN BAND"},{"number":"1030743","date":"2019-12-13","work":"Sign","type":"BP_SIGN","description":"SIGN PERMIT","status":"COMPLETED","completedDate":"2020-01-10","scope":"INSTALL CHANNEL LETTERS ON EXISTING SIGN BAND"},{"number":"1036769","date":"2020-01-03","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2021-09-13","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR REPLACEMENT OF ELEVATOR LOBBY DOOR ON THE 18TH FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL WORK**"},{"number":"995494","date":"2020-01-31","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2022-03-23","scope":"ALTERATIONS: INTERIOR PLUMBING; 32ND FL-THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004 (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 32ND FLOOR OF AN EXISTING BUILDING (WEST TOWER) 1-WATER CLOSET, 1-LAV & 3-SINK"},{"number":"1046751","date":"2020-02-13","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2021-06-03","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 8TH FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**"},{"number":"1049457","date":"2020-02-13","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2022-04-07","scope":"ONE FOR ONE REPLACEMENT OF 5-WATER CLOSETS AND 3-URINALS ONLY WITH NO ADDITIONAL PIPING.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2018"},{"number":"1051127","date":"2020-02-20","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2020-06-15","scope":"EZ INTERIOR DEMOLITION- For the interior demolition on non-bearing partition wall and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. . Structural alteration or repair is expressly prohibited under this permit. Prohibited structural work includes any modification to exterior walls, party walls, floor/roof framing or foundations. FLOORS 20,21,22,25,26,27,28,29 ( 2 PARTIAL FLOORS 30 & 31), ( AND LOWER MEZZANINE LEVEL 5TH FL)"},{"number":"1054770","date":"2020-03-04","work":"New Construction","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2021-06-03","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"1054829-RI","date":"2020-03-04","work":"Rough-In","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-03-17","scope":"FIT OUT FOR OFICE SPACE PLUMBING ALL CONNECTIONS WILL TIE INTO EXISTING UTILITIES FIXTURE COUNT= 2 WC, 2 LAV, 5 SINKS 2 ECW"},{"number":"1054912-RI","date":"2020-03-04","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-06-12","scope":"INSTALL RECEPTACLES, FURNITURE FEEDS, LIGHT FIXTURES AND LIGHTING CONTROLS PER 2017 NEC (CC DIST)"},{"number":"1052561","date":"2020-03-05","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-09-15","scope":"FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, DOORS, FINISHES, FURNISHINGS, AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. **IEBC 2018**"},{"number":"1046055","date":"2020-03-05","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-06-26","scope":"FOR PRESCRIPTIVE ALTERATIONS TO REMOVE AN INTER-STORY STAIR BETWEEN THE 30TH AND 31ST FLOORS AND FOR STRUCTURAL WORK TO FILL-IN THE FLOOR OPENING OF AN EXISTING HIGH-RISE OFFICE BUILDING (EAST TOWER), AS PER PLANS; NO OTHER WORK ON THIS PERMIT."},{"number":"1053825","date":"2020-03-09","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2021-06-03","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"1056389-RI","date":"2020-03-10","work":"Rough-In","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-04-20","scope":"ELECTRICAL DEMOLITION, TEMPORARY LIGHTING AND GFI RECEPTACLES-EXTEND EXISTING TENAT SERVICE TO NEW DISTRUBUTION EQUIPMENT-NEW PANELS, TRANSFORMERS AND METERS-NEW BRANCH WIRING FROM NEW PANELS-NEW RECEPTACLES AND FLOOR MOUNTED POKETHURS-POWER AND CONN"},{"number":"1057336","date":"2020-04-21","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2020-09-15","scope":"FOR LEVEL II INTERIOR ALTERATION WITHOUT CHANGE OF OCCUPANCY ON 18TH FLOOR COMMON AREA OF EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEPS WORK."},{"number":"1052055","date":"2020-04-21","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-06-17","scope":"SELECTIVE DEMO OF LIGHTS, POWER AND T/D PER 2017 NEC (CC DIST)"},{"number":"1054829","date":"2020-04-23","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2021-06-03","scope":"FIT OUT FOR OFICE SPACE PLUMBING ALL CONNECTIONS WILL TIE INTO EXISTING UTILITIES FIXTURE COUNT= 2 WC, 2 LAV, 5 SINKS 2 ECW"},{"number":"EP-2020-000255","date":"2020-05-04","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-08-31","scope":"Furnish and install One Hundred and Two (102) new telecommunication/data Category 6 low voltage cable locations. Furnish and install Ten (10) 18/2 and 22/6 low voltage cables for door access control. All work as per 2017 NEC."},{"number":"PP-2020-000648","date":"2020-05-15","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-12-17","scope":"Install 2 Sinks, Install 2 Water heaters. Installation must comply with 2018 Philadelphia Plumbing Code section 919"},{"number":"EP-2020-000851","date":"2020-05-19","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-08-26","scope":"Install (9) speaker/strobe devices as per NFPA 72."},{"number":"EP-2020-000963","date":"2020-06-08","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-08-26","scope":"Install and replacement of lighting fixtures throughout 18th floor common area. Install replacement of speaker/strobe fire alarm devices (no new devices) PER THE 2017 NEC"},{"number":"1056389","date":"2020-06-08","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2022-07-11","scope":"ELECTRICAL DEMOLITION, TEMPORARY LIGHTING AND GFI RECEPTACLES-EXTEND EXISTING TENAT SERVICE TO NEW DISTRUBUTION EQUIPMENT-NEW PANELS, TRANSFORMERS AND METERS-NEW BRANCH WIRING FROM NEW PANELS-NEW RECEPTACLES AND FLOOR MOUNTED POKETHURS-POWER AND CONN"},{"number":"MP-2020-001157","date":"2020-06-09","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2020-09-15","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Replacing 15 Grilles"},{"number":"PP-2020-002915","date":"2020-06-10","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2020-06-22","scope":"Replace (8) Lavatories Replace (2) Urinals) Replace (9) Water Closets Using existing Rough Ins. No new piping associated with this permit."},{"number":"1054912","date":"2020-06-12","work":"New Construction","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-08-26","scope":"INSTALL RECEPTACLES, FURNITURE FEEDS, LIGHT FIXTURES AND LIGHTING CONTROLS .ALL WORK SHALL BE DONE ACCORDING TO THE 2017 NEC (CC DIST)"},{"number":"EP-2020-000960","date":"2020-06-30","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2020-08-24","scope":"Install of lighting fixtures throughout 18th floor common area."},{"number":"FP-2020-000010","date":"2020-07-06","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2020-09-15","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"PP-2020-004813","date":"2020-07-13","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2022-03-10","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"MP-2020-002018","date":"2020-07-21","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2022-08-16","scope":"FOR THE INSTALLATION OF ONE (1) HEAT PUMP WITH NEW REGISTERS/DIFFUSERS AND ASSOCIATED DUCTWORK AND THE RELOCATION OF VAV'S ON THE 18TH FLOOR OF AN EXISTING HIGH RISE, AS PER APPROVED PLANS."},{"number":"CP-2020-005614","date":"2020-10-28","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-03-23","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING BUISNESS USE ON THE 24TH FLOOR LEVEL TO INCLUDE THE ERECTION OF PARTITION WALLS, REPLACEMENT OF FIXTURES, INSTALLATION OF FINISHES AND FURNISHINGS. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2020-006193","date":"2020-11-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-03-08","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING 24TH FLOOR OFFICE SPACE AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"CP-2020-005687","date":"2020-11-10","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2022-05-25","scope":"FOR EXTERIOR WORK. FOR NEW PAVER INSTALLATION AND CONCRETE REPAIRS AS PER APPROVED PLAN. ANY DEVIATION TO THE APPROVED SCOPE OF WORK WILL REQUIRE THE PERMIT TO BE AMENDED**EXTERIOR WORK ONLY**"},{"number":"PP-2020-012459","date":"2020-11-10","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-03-08","scope":"Furnish and install [1] pantry sink, [1] water heater and [1] hub drain"},{"number":"FP-2020-002159","date":"2020-11-10","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-03-08","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (71) SPRINKLER HEADS ON THE 24th FLOOR AS PER NFPA 13"},{"number":"PP-2020-012858","date":"2020-11-16","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-03-23","scope":"Remove fixtures on 24th floor core restroom and replace with new in same location"},{"number":"FP-2020-002216","date":"2020-11-17","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-03-23","scope":"We will be relocating (28) sprinklers in the West Tower, 24th floor corridor."},{"number":"EP-2020-009930","date":"2020-11-18","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-25","scope":"Interior renovation including new LED lighting, and receptacles as per 2017 NEC."},{"number":"EP-2020-010076","date":"2020-11-26","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-03-08","scope":"1 Temporary Lighting and Power Lighting 27 Type F1 6 Type F2-6' 2 Type F3 23 Type F4 2 Type F5-17' 1 Type F5-14.5' 1 Type F5-18.5' 12 Type F6 @ 8'5\" W/ remote LED drivers 11 Exit Lights 1 Tie new lighting into existing building lighting controls 1 Wall mounted occupancy sensor 1 Replace existing receptacles with new As per 2017 nec"},{"number":"EP-2020-011080","date":"2020-12-09","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-02-25","scope":"Installation of 186 Category 6 plenum rated 4 pair 23AWG cables to various location on 24th floor West tower. All cable will be supported with Jhooks or conduit and all fire walls will be fire stopped as per 2017 nec"},{"number":"MP-2020-006140","date":"2020-12-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-03-08","scope":"FOR THE INSTALLATION OF NEW DUCTWORK, GRD'S AND FAN BOXES ON THE 24TH FLOOR - STATE FARM SPACE, OF AN EXISTING HIGH RISE, AS PER APPROVED PLANS."},{"number":"EP-2020-011353","date":"2020-12-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-01-29","scope":"Upgrade Fire Alarm in Tenant Suite as per APPROVED DRAWINGS- 2016nfpa 72"},{"number":"MP-2020-006790","date":"2021-01-04","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-03-23","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - (Relocate [2] existing thermostats and [13] diffusers . Provide air balance report). For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (Note: rooftop installations will require plans unless it has already been included on any approved alteration plans.)"},{"number":"EP-2021-000579","date":"2021-01-20","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2023-01-24","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"CP-2021-000499","date":"2021-02-23","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2022-03-17","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACES ON THE LOWER MEZZANINE, 14TH, 15TH, 16TH, AND 17TH FLOORS OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK** AMENDMENT APPROVED 3/13/21 AMEND ALTERATIONS PERMIT CP-2021-000499 FOR CHANGES TO LOWER MEZZANINE LAYOUT AS PER APPROVED PLANS."},{"number":"FP-2021-000573","date":"2021-03-04","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2022-02-02","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (10) sprinkler heads on the 16th & 17th floors (CP-2021-000499)"},{"number":"EP-2021-001776","date":"2021-03-09","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-08-04","scope":"(22) ? Disconnect existing demountable wall partitions, retain existing feed for new partitions (18) ? Reconnect existing circuits to (18) new demountable wall connections. (71) ? Remove existing light fixtures, retain designated fixtures for reinstallation in new finishes (71) ? Retain light fixture circuitry for connection to reinstalled/new lighting fixtures (08) ? Install new Type F1-8? fixtures connected to existing circuitry (02) ? Install new Type F2-8? fixtures connected to existing circuitry (05) ? Install new Type F3 fixtures connected to existing circuitry (56) ? Install new Type F4 fixtures connected to existing circuitry (13) ? Remove ceiling mounted occupancy sensors, retain for reinstallation in new finishes (09) ? Install salvaged ceiling mounted occupancy sensors (04) - Remove existing ceiling mounted fire alarm devices for reinstallation in new finishes at same location. (No new wiring) Provide F/A test and recertification upon completion of project. As per 2017 nec AMENDMENT 6-1-2021: The list of additional scope of work to be completed is: 10 Lighting fixtures 08 Switches 11 Receptacles 01 90 Amp, 208 Volt, 3? Dryer connection 01 20 Amp, 208 Volt, 1? Washer connection 04 F/A Speaker/Strobe 01 F/A Speaker/strobe to be relocated 01 F/A Testing & recertification of system"},{"number":"CP-2021-000315","date":"2021-03-12","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-05-11","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO SUBDIVIDE EXISTING GROUND FLOOR SHELL COMMERCIAL SPACE INTO TWO SPACES AND FOR THE INSTALLATION OF NEW ACCESSIBLE LIFT AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR FIT-OUT OF SPACE(S) PRIOR TO OCCUPANCY. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK** AMENDMENT APPROVED 4/12/21 AMEND ALTERATIONS PERMIT CP-2021-000315 TO REMOVE ACCESSIBLE LIFT FROM SCOPE OF WORK AS PER APPROVED REVISED PLANS."},{"number":"MP-2021-001571","date":"2021-03-22","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2022-02-02","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND ASSOCIATED DUCTWORK TO EXTEND AN EXISTING HVAC SYSTEM AT THE LOWER MEZZANINE, 14TH, 15TH, 16TH, AND 17TH FLOORS. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2021-000499 FOR ASSOCIATED ALTERATIONS WORK."},{"number":"ZP-2021-001353","date":"2021-04-02","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Completed","completedDate":"2022-01-31","scope":"For the erection of two(2) statically illuminated flatwall signs. size and location as shown in plan. Signs accessory to an existing financial institution"},{"number":"CP-2021-000217","date":"2021-04-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2021-10-29","scope":"For level II alteration- tenant fitout of an existing shell space into a bank branch as per approved plans. Separate permits required for MEPS work. Existing building is fully sprinklered. AMENDMENT FOR MINOR CHANGE TO FLOOR LAYOUT AS PER APPROVED REVISED PLANS."},{"number":"PP-2021-005855","date":"2021-04-12","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2022-02-02","scope":"Furnish and install [4] water closet, [3] lavatories , [1] wash machine box for laundry room"},{"number":"FP-2021-001055","date":"2021-04-14","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2022-10-31","scope":"We will be relocating (24) sprinklers on the 43rd Floor. There is NO building permit. THERE IS NO BUILDING PERMIT"},{"number":"FP-2021-001141","date":"2021-04-15","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2021-10-29","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (27) Sprinkler Heads First Floor Tenant Space. Suite L470. (CP-2021-000217)"},{"number":"GP-2021-004152","date":"2021-05-21","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2022-01-31","scope":"FOR THE ERECTION OF TWO (2) STATIC INTERNALLY ILLUMINATED WALL SIGNS ACCESSORY TO A FINANCIAL INSTITUTION. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK. SIGNS PERMIT ONLY."},{"number":"GM-2021-005142","date":"2021-05-25","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2021-08-13","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2021-006438","date":"2021-06-10","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-10-29","scope":"Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018."},{"number":"EP-2021-006313","date":"2021-06-16","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-10-13","scope":"INSTALLATION OF IP NETWROK VIDEO SYSTEM, 16 IP NETWORK CAMERAS, NETWORK VIDEO SERVER. INSTALLATION OF SECURITY SYSTEM, ONE CONTROL PANEL, TWO USER INTERFACES, SIX MOTION DETECTORS, EIGHT HOLDUP BUTTONS, EIGHT SECURITY DOOR CONTACTS AND TWO GLASS BREAK DETECTORS. ATM CARD ACCESS CARD READER AND ONE LOCK. NETWORK CAT5e CABLE CONCEALED AND CLASS 2 CABLE CONCEALED AS PER NEC 2017"},{"number":"MP-2021-002635","date":"2021-06-22","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2021-10-29","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (New/Modification to Mechanical Ductwork Plan No HVAC Equipment being installed. Only Modification)."},{"number":"EP-2021-006088","date":"2021-07-06","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-10-05","scope":"Riley Electric will be providing labor only for the following work: Install j-hook cable supports in the branch ceiling. Install two four-inch pass-through sleeves for cable migration into the IT room. Install Category 6 cables (grey) for 15 workstations and one AP location, according to the provided print. Install a wall-mount data rack and 48-port Category 6 patch panel in the IT Room. Ground a data rack to the provided bus bar in IT Room. Terminate cables on the patch panel and extend the provided demark circuits in the IT Room to the patch panel. Terminate the stations with Category 6 grey jacks and white faceplates. Test and label all Category 6 cabling. As per 2017 NEC"},{"number":"EP-2021-005349","date":"2021-08-02","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-10-14","scope":"Electrical fit-out of existing white shell for use of bank. Main service into space is existing. Fire alarm system shall be extended from buildings main provider.ALL WORK TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC ,2018 PHILA FIRE CODE AND 2016 NFPA-72."},{"number":"CP-2021-004663","date":"2021-08-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Expired","completedDate":"2023-10-20","scope":"FOR INTERIOR ALTERATIONS TO AN EXISTING SPACE TO INCLUDE NEW INTERIOR PARTITION WALLS AND WALL/FLOOR/CEILING FINISHING. (IEBC 2018, WORK-AREA METHOD, LVL II ALTERATIONS) **SEPARATE PERMITS REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE SUPPRESSION SYSTEM ALTERATIONS.**"},{"number":"FP-2021-002346","date":"2021-08-20","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Expired","completedDate":"2023-10-20","scope":"Relocate (15) sprinkler heads in suite 2740 as per NFPA 13 See CP-2021 004663"},{"number":"PP-2021-015255","date":"2021-08-20","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2023-10-20","scope":"Furnish and install [2] sinks REPLACEMENT"},{"number":"EP-2021-009112","date":"2021-08-26","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-01-18","scope":"55 Lighting fixtures 8 Single Pole Switch 2 Three Way Switch 1 Power supply @ 120 volts for Security 12 Gfi Dedicated Receptacles 27 Duplex Receptacles 15 IG Receptacles 2 TV Receptacle 6 Furniture Feed - Wall 3 Conference Rm stub up with table connection 1 Exhaust Fan to Wire and Connect 2 Dishwashers to wire and connect 1 Wire And Connect to Existing Panelboards Fire Alarm 12 Speaker/strobe 1 Door release relay to wire and connect. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"EP-2021-009869","date":"2021-09-09","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2022-02-23","scope":"Furnish & Install 91 Plenum Cat 6 Cabling as per 2017 nec"},{"number":"MP-2021-005497","date":"2021-09-13","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2023-10-20","scope":"FOR ALTERATIONS TO THE EXISTING HVAC SYSTEM THROUGHOUT SUITE #2740 TO INCLUDE THE INSTALLATION OF NEW REGISTERS / DIFFUSERS AND ASSOCIATED DUCTWORK SERVED BY EXISTING VAVs. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2021-004663 FOR ASSOCIATED BUILDING ALTERATIONS PERMIT."},{"number":"ZP-2021-008748","date":"2021-09-20","work":"New construction, addition, GFA change","type":"Zoning","description":"Zoning Permit","status":"Completed","completedDate":"2022-03-02","scope":"FOR THE INTALLATION OF ONE (1), 500-GALLON, DOUBLE WALL ABOVE GROUND STORAGE TANK SYSTEM. SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLANS."},{"number":"GP-2021-007597","date":"2021-10-25","work":"Tank Install/Removal","type":"General","description":"General Permit","status":"Completed","completedDate":"2022-03-02","scope":"Supply and install one (1) 500 gallon, double wall Fireguard Aboveground Storage Tank system for the storage of diesel fuel for an emergency generator. Close-in-place one (1) 900 gallon Aboveground Storage Tank (belly tank for emergency generator). Zoning Permit No. #ZP-2021-008748 has been issued for this project."},{"number":"CP-2022-001205","date":"2022-03-11","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-03-14","scope":"FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE (L455)USED AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2022-003296","date":"2022-04-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-09-27","scope":"• MacDonald Electric will install 1–100-amp 480-volt feed from lower-level electrical distribution approximately 200’ away to facilitate power to new distribution. • MacDonald Electric will furnish and install 1-45 kVA transformer above ceiling that will convert power to 480-volt 3 phase to 120/208-volt 3 phase 4 wire 200 amps. • MacDonald Electric will furnish and install 1–200-amp 120/208-volt 3 phase 4 wire fuse disconnect switch on secondary side of transformer. • MacDonald Electric will provide 1–200-amp 3 phase 4 wire feed to new distribution panel from load side of disconnect. • MacDonald Electric will provide 1–200-amp 120/208-volt 3 phase 4 wire 42 circuit main lug only distribution panel with flush mount cover. • MacDonald Electric will provide 2–30-amp 2 pole breakers, 2–20-amp 2 pole breakers, and 15–20-amp single pole breakers for future loads. • MacDonald Electric will provide 12-2x2 lay in Columbia fixtures. • MacDonald Electric will provide demo of existing lighting, receptacles, and 60-amp 208-volt panel. • MacDonald Electric will provide and install 2 new exit signs. • MacDonald Electric will provide tie in of 2 light fixtures to emergency building lighting circuit. • MacDonald Electric will provide saw cutting of dry wall ceiling to hang transformer from. (Please note: drywall ceiling will have to be patched by others). • MacDonald Electric will provide one 100am 480Volt Emon Dmon meter for metering of electrical consumption. • MacDonald Electrical will provide necessary coring of concrete deck and patching to facilitate installation of 480Volt feeder. • MacDonald Electric will furnish and install necessary disconnect switches for RTU. • MacDonald Electric will provide engineered drawings, permitting and inspection • MacDonald Electric will be providing 208-volt feeder as required per new single line provided for RTU. As per 2017 nec"},{"number":"GP-2021-013847","date":"2022-04-21","work":"Sign","type":"General","description":"General Permit","status":"Expired","completedDate":"2025-03-27","scope":"For the erection of one (1) window sign as per approved plans accessory to an existing financial institution."},{"number":"FP-2022-001207","date":"2022-04-26","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-03-14","scope":"Modifying 9 Sprinklers EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans."},{"number":"MP-2022-002043","date":"2022-04-28","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-03-14","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED WORK FOR A BUSINESS OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"CP-2022-005839","date":"2022-10-20","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-03-31","scope":"FOR A LEVEL II INTERIOR ALTERATION TO THE 19TH &20TH FLOOR LEVEL.FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"ZP-2022-010179","date":"2022-10-28","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Eating and Drinking Establishments - Take-Out Restaurant"},{"number":"CP-2022-004403","date":"2022-11-01","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-11-03","scope":"FOR LEVEL II INTERIOR ALTERATIONS AND CHANGE IN OCCUPANCY PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING."},{"number":"EP-2022-009906","date":"2022-11-18","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-05-04","scope":"Installation of light throughout unit, outlets and switches, partial rewire wiring as needed throughout unit min. existing wiring and service as per code NEC 2017"},{"number":"FP-2022-003109","date":"2022-11-29","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-03-30","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. (CP-2022-005839) Relocate (51) sprinkler heads on the 19th & 20th floors as per NFPA 13"},{"number":"EP-2022-011996","date":"2022-11-29","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-03-20","scope":"F&I (30) Dual Cat6 Plenum Cables. F&I (60) Single Cat6 CommScope Cat6 RJ-45 Outlets. F&I (2) Unloaded Cat6 CommScope 48 Port Patch Panels AS PER NEC 2014"},{"number":"EP-2022-012044","date":"2022-12-07","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-03-15","scope":"Furnish and install lighting, power and distribution . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC . **SEPARATE FIRE ALARM PERMIT REQ'D** AMENDMENT: Remove and reinstall fire alarm devices, and add two notification appliances ."},{"number":"MP-2022-006251","date":"2022-12-28","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-03-30","scope":"FOR THE INSTALLATION OF DIFFUSERS AS PER PLANS."},{"number":"PP-2022-018155","date":"2022-12-28","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-03-31","scope":"Furnish and install [1] breakroom sink, [1] open site drain and [1] electric water heater Provide labor and material extend from existing sanitary, vent and domestic cold water stacks."},{"number":"FP-2022-003319","date":"2022-12-29","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-03-27","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (33) sprinkler heads in lower mezzanine"},{"number":"CP-2022-005872","date":"2023-01-03","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-03-27","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING SHELL SPACE ON THE LOWER MEZZANINE FOR A NEW OFFICE SUITE FIT-OUT AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"PP-2023-000074","date":"2023-01-09","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-03-27","scope":"Install indirect drain and a water line for an office ice machine."},{"number":"EP-2023-000876","date":"2023-02-06","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-03-21","scope":"Supply / install all conduit, wiring, receptacles, switches, devices, junction boxes, cover plates, etc. required for a complete electrical system . Install fire alarm. Supply / install lighting fixtures, including hangers, clamps, and lamps. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"MP-2023-000306","date":"2023-02-20","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-03-27","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"CP-2023-000058","date":"2023-02-22","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-09-01","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 29TH FLOOR OFFICE SPACE WITHIN AN EXISTING HIGH-RISE OFFICE BUILDING (WEST TOWER) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"FP-2023-000483","date":"2023-03-07","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-08-31","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (96) SPRINKLER HEADS AS PER NFPA 13"},{"number":"PP-2023-003036","date":"2023-03-07","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-08-15","scope":"Furnish and install [1] Sink and [1] on demand water heater. Provide labor and material to extend from existing sanitary, vent and domestic cold water mains as shown on drawings."},{"number":"EP-2023-002154","date":"2023-03-09","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-08-17","scope":"Installation of (98) Cat-6 cables in accordance with all NEC 2017"},{"number":"MP-2023-001077","date":"2023-03-13","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-08-15","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"PP-2023-002706","date":"2023-04-03","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2023-07-12","scope":"Furnish and install new plumbing fixtures, with sanitary, sanitary vent and domestic water piping, (4) sinks, (1) mop receptor and (4) floor drains, as per plans"},{"number":"EP-2023-002229","date":"2023-05-17","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-08-22","scope":"Electrical demolition, temporary lighting and power, (QTY. 1) 100A, 208/120V panel, light fixtures, receptacles, and empty raceways for low voltage systems as per 2017 NEC. Install fire alarm as per 2016 NFPA 72."},{"number":"CP-2023-002685","date":"2023-05-25","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-11-03","scope":"LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 29TH FLOOR COMMON CORRIDOR AND ELEVATOR LOBBY AREAS IN AN EXISTING HIGH-RISE BUILDING (WEST TOWER) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**"},{"number":"CP-2023-002914","date":"2023-05-30","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2023-11-03","scope":"FOR A LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 27TH FLOOR LEVEL. FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"FP-2023-001172","date":"2023-06-02","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-11-02","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (20) SPRINKLER HEADS ON 29TH FLOOR AS PER NFPA 13"},{"number":"FP-2023-001232","date":"2023-06-05","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2023-11-02","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 25 SPRINKLER HEADS AS PER NFPA 13"},{"number":"MP-2023-002573","date":"2023-06-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-11-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. relocate [10] diffusers and provide air balance report."},{"number":"EP-2023-006343","date":"2023-07-18","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-01-04","scope":"Installation of (81) Cat-6 data low voltage cables in accordance with all NEC 2017"},{"number":"MP-2023-003125","date":"2023-08-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2023-11-02","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK FOR A BUSINESS OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2023-006450","date":"2023-08-09","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-10-27","scope":"REPLACEMENT OF EXISTING LIGHTING AND RECEPTACLES ON THE 29th FLOOR CORRIDOR AND RESTROOMS. CONNECT TO EXISTING CIRCUITS. REPLACEMENT OF FIRE ALARM DEVICES ONLY ACCORDING TO THE 2017 NEC, 2016 NFPA AND PER PLANS."},{"number":"EP-2023-006491","date":"2023-08-15","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-10-06","scope":"Provide new lighting ,receptacles and fire alarm . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE."},{"number":"AP-2023-006123","date":"2023-08-30","work":"Certificate of Occupancy (CO) (may inclu…","type":"Administrative","description":"Administrative Permit","status":"Cancelled","completedDate":"2024-07-11","scope":"FOR THE CERTIFICATE OF OCCUPANCY GROUP B (TAKEOUT RESTAURANT) PER APPROVED PLANS. NO CONSTRUCTION WORK ON THIS PERMIT. **FOR CONSTRUCTION WORK SEE CP-2022-004403**"},{"number":"CP-2023-006977","date":"2024-01-08","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-02-15","scope":"FOR LEVEL II INTERIOR ALTERATION TO AN EXISTING TENANT SPACE ON THE 19TH FLOOR LEVEL FOR USE AS A BUSINESS OCCUPANCY. FOR THE CREATION OF AN ADDITIONAL OFFICE SPACE, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS. BUILDING TO BE FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**"},{"number":"CP-2024-000411","date":"2024-02-20","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-09-13","scope":"FOR LEVEL II ALTERATIONS WITH NO CHANGE IN OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK."},{"number":"ZP-2023-013458","date":"2024-03-07","work":"Signs (Accessory / Non-Accessory)","type":"Zoning","description":"Zoning Permit","status":"Completed","completedDate":"2024-07-18","scope":"FOR ERECTION OF ONE (1) FLAT WALL SIGN ON EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLAN."},{"number":"CP-2024-000560","date":"2024-04-17","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-06-14","scope":"FOR A LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY ). ALTERATIONS TO INCLUDE INSTALLATION OF NEW WALL PARTITIONS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT AS PER APPROVED PLANS. ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK**IEBC 2018**EXISTING BUILDING FULLY SPRINKLERED** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**"},{"number":"EP-2024-003685","date":"2024-04-18","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-06-10","scope":"Selective electric demo, Replacing 12 existing 2x2 recessed fluorescent fixtures with 12 new LED 2x2 fixtures . Replacing 2 exit signs and emergency lights. Installing 4- 120 volt 20 ampere outlets . F& I 4 connectrac floor outlets and Cat 6 cabling to check out booths. Also wiring up power to small kitchenette"},{"number":"GP-2024-002193","date":"2024-05-22","work":"Sign","type":"General","description":"General Permit","status":"Completed","completedDate":"2024-07-18","scope":"FOR ERECTION OF ONE (1) FLAT WALL SIGN ON EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2024-001067","date":"2024-05-23","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2024-09-13","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (19) SPRINKLER HEADS IN STARBUCKS AS PER NFPA 13"},{"number":"EP-2024-004478","date":"2024-06-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-12","scope":"INSTALL NEW LIGHT FIXTURES NORMAL & EMERGENCY, SWITCHES & SENSORS FED FROM THE EXISTING CIRCUITING. CLEAN & RELAMP EXISTING LIGHT FIXTURES AS REQUIRED. INSTALL RECEPTACLES & FLOOR OUTLET USING THE EXISTING CIRCUITS. INSTALL NEW SPEAKERS. PROVIDE EMPTY CONDUITS FOR THE TELE COM WIRING. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. * NO SERVICE WORK. ** NO FIRE ALARM WORK."},{"number":"PP-2024-007448","date":"2024-06-24","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2024-09-13","scope":"INSTALL 3 HAND SINKS, 2 WATER CLOSETS, 2 LAVATORIES, 7 FLOOR SINKS, 2 FLOOR DRAINS, 1 MOP SINK AND 1 HOT WATER HEATER ACCORDING TO THE 2018 PPC AND PER PLANS."},{"number":"MP-2024-002567","date":"2024-06-28","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2024-09-13","scope":"FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK."},{"number":"EP-2024-005818","date":"2024-07-01","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-09-12","scope":"Fire alarm installation per engineered drawings and 2016 NFPA 72."},{"number":"EP-2024-007200","date":"2024-07-26","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Expired","completedDate":"2025-08-05","scope":"Installing approx 150' of 1\" EMT for Cat 6 wire for cameras. Wire by others. All work to be done in parking garage"},{"number":"ZP-2024-001368","date":"2024-08-07","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Personal Vehicle Sales and Rentals."},{"number":"CP-2024-004784","date":"2024-09-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-11-01","scope":"FOR LEVEL II ALTERATIONS AT SUITE 1800 OF AN EXISTING BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"EP-2024-009035","date":"2024-09-20","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2024-10-28","scope":"Relocate Existing Wiring for Power & Lighting via Fishing. No new Interior wiring."},{"number":"CP-2025-001821","date":"2025-04-21","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-08-13","scope":"FOR LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE (SPACE #2410) FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE SELECTIVE DEMOLITION OF EXISTING PARTITION AND THE ERECTION OF NEW WALL PARTITIONS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"FP-2025-000887","date":"2025-04-28","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-08-13","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (9) sprinkler heads to accommodate interior alterations to tenant space"},{"number":"GM-2025-004146","date":"2025-05-02","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2026-05-07","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"PP-2025-005532","date":"2025-05-07","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-08-13","scope":"Furnish and install (2) new plumbing fixtures, (1) kitchen sink and (1) water heater, connecting to existing piping."},{"number":"MP-2025-002610","date":"2025-05-08","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-08-13","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Additional permits may be required. Furnish labor to relocate 7 existing diffusers with no wall penetrations within a single tenant space area. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies."},{"number":"GM-2025-004476","date":"2025-05-12","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2026-05-07","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"GM-2025-004475","date":"2025-05-12","work":"Interior Non-Load-Bearing Wall Demo.","type":"General Permit Minor","description":"General Permit Minor","status":"Expired","completedDate":"2026-05-07","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"EP-2025-004381","date":"2025-05-15","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-07-22","scope":"Furnish and install 8 duplex outlets, 2 furniture feeds, 1 GFI, Relocate 14 F-1, 2 F-2 and one exit sign Fire Alarm , testing for re-certification. .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72."},{"number":"CP-2025-003126","date":"2025-06-16","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2025-12-08","scope":"FOR LEVEL II ALTERATIONS TO CONCOURSE AND 24TH FLOOR IN AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. ***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************"},{"number":"FP-2025-001294","date":"2025-06-18","work":"Addition and/or Alterations","type":"Fire Suppression","description":"Fire Suppression Permit","status":"Completed","completedDate":"2025-12-05","scope":"EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 39 Sprinkler Heads"},{"number":"MP-2025-003375","date":"2025-07-08","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Completed","completedDate":"2025-12-05","scope":"FOR THE INSTALLATION OF HVAC APPLIANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS."},{"number":"EP-2025-006669","date":"2025-07-21","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2025-10-15","scope":"Furnish and install 19 duplex outlets, 11 quads, 6 L6-30R, 15 dedicated outlets, 2 floor cores, 2 furniture feeds and one hot water heater. 56 2x4 fixtures to match existing, 1 linear, 3 new exits to match existing, 10 wall motions and 1 ceiling motion Existing fire alarm to remain. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC."},{"number":"PP-2025-007933","date":"2025-07-25","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2025-12-08","scope":"Demo (2)- Pantry Sink 24th fl Move all piping approx 10' to new location Install (2)- Pantry sink (1)- Water Heater"},{"number":"CP-2026-001042","date":"2026-03-09","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Issued","completedDate":null,"scope":"FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN USE AND OCCUPANCY CLASSIFICATION TO A GROUP B OFFICE (SUITE #4110) AND COMMON CORRIDOR TO INCLUDE NEW INTERIOR FINISHES, MILLWORK, DOORS, FRAMES, AND HARDWARE. EXISTING BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK."},{"number":"PP-2026-002991","date":"2026-03-10","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Issued","completedDate":null,"scope":"Provide labor and material to replace [1] sink at Pantry Area. *WITHOUT PIPING*"},{"number":"EP-2026-002042","date":"2026-03-11","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2026-07-08","scope":"Furnish and install 1 quad outlet, 3 2x2 light fixtures and one wall motion sensor"}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"permit","w":"Alterations"},{"y":2025,"k":"insp","w":"Inspection failed ×2"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"permit","w":"Alterations"},{"y":2026,"k":"permit","w":"Addition and/or Alteration"},{"y":2026,"k":"viol","w":"L&I violation"},{"y":2026,"k":"insp","w":"Inspection failed ×3"}],"rented":false,"licenses":[{"number":"205991","type":"Food Preparing and Serving","status":"Inactive","businessName":"KAWEJO INC","legalName":"KAWEJO INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2001-06-07","latestIssueDate":"2001-06-07","expirationDate":"2002-04-30","inactiveDate":null},{"number":"202671","type":"Food Preparing and Serving","status":"Inactive","businessName":"AMY ENTERPIRSES INC","legalName":"AMY ENTERPIRSES INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2002-04-11","latestIssueDate":"2002-04-11","expirationDate":"2003-04-30","inactiveDate":null},{"number":"200797","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"GERTRUDE HAWK CHOCOLATES INC","legalName":"GERTRUDE HAWK CHOCOLATES INC","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2002-10-29","latestIssueDate":"2002-10-29","expirationDate":"2003-04-30","inactiveDate":null},{"number":"206484","type":"Food Preparing and Serving","status":"Inactive","businessName":"APS I INC","legalName":"APS I INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2004-04-30","latestIssueDate":"2018-04-16","expirationDate":"2019-04-30","inactiveDate":"2019-06-29"},{"number":"200228","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"EXPRESSIONS 11 CARDS AND GIFTS","legalName":"EXPRESSIONS 11 CARDS AND GIFTS","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2004-05-16","latestIssueDate":"2010-01-05","expirationDate":"2010-04-30","inactiveDate":"2012-12-22"},{"number":"199976","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"FABER COE & GREGG OF PA INC (PHILLY NEWS NOW)","legalName":"FABER COE & GREGG OF PA INC","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2004-05-20","latestIssueDate":"2009-04-22","expirationDate":"2010-04-30","inactiveDate":"2012-12-22"},{"number":"299157","type":"High Rise","status":"Closed","businessName":"REIT MANAGEMENT & RESEARCH LLC","legalName":"REIT MANAGEMENT & RESEARCH LLC","address":"1500-42 MARKET ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2004-05-26","latestIssueDate":"2014-05-06","expirationDate":"2015-04-30","inactiveDate":"2015-06-29"},{"number":"200807","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"SUB STAT SOFT PRETZEL FACTORY","legalName":"SUB STAT SOFT PRETZEL FACTORY","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2004-06-18","latestIssueDate":"2004-06-18","expirationDate":"2006-04-30","inactiveDate":"2012-12-22"},{"number":"209699","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"PHILADELPHIA DAKOTAS INC","legalName":"PHILADELPHIA DAKOTAS INC","address":"1500-42 MARKET ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2004-08-26","latestIssueDate":"2004-08-26","expirationDate":"2005-04-30","inactiveDate":"2012-12-22"},{"number":"207705","type":"Food Preparing and Serving","status":"Active","businessName":"STARBUCKS CORPORATION (STARBUCKS COFFEE # 7840)","legalName":"STARBUCKS CORPORATION","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2004-09-02","latestIssueDate":"2026-05-04","expirationDate":"2027-04-30","inactiveDate":null},{"number":"200747","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"JAYSHREE & KIRIT DESAI","legalName":"JAYSHREE & KIRIT DESAI","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2004-09-16","latestIssueDate":"2006-06-30","expirationDate":"2007-04-30","inactiveDate":"2008-07-28"},{"number":"284819","type":"Public Garage / Parking Lot","status":"Inactive","businessName":"CENTRAL PARKING SYSTEMS OF PA INC","legalName":"CENTRAL PARKING SYSTEMS OF PA INC","address":"1500-42 MARKET ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2005-01-03","latestIssueDate":"2013-04-06","expirationDate":"2013-12-31","inactiveDate":"2013-12-16"},{"number":"425651","type":"Food Preparing and Serving","status":"Inactive","businessName":"NEW LIVING INC (RAINDROP CAFE)","legalName":"NEW LIVING INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2007-10-05","latestIssueDate":"2012-03-15","expirationDate":"2012-04-30","inactiveDate":"2012-12-22"},{"number":"452457","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"ABHAY & BINA V SHETH (ANAR NEWS)","legalName":"ABHAY & BINA V SHETH","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2008-07-28","latestIssueDate":"2015-07-03","expirationDate":"2016-04-30","inactiveDate":"2016-06-29"},{"number":"478201","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"CLOTHESPIN ENTERPRISES LLC (THE AMERICAN PUB)","legalName":"CLOTHESPIN ENTERPRISES LLC","address":"1500-42 MARKET ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2009-07-02","latestIssueDate":"2014-04-08","expirationDate":"2015-04-30","inactiveDate":"2015-06-29"},{"number":"495501","type":"Food Establishment, Retail Permanent Location","status":"Inactive","businessName":"SHAILESH N TILVAWALA","legalName":"SHAILESH N TILVAWALA","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2010-03-12","latestIssueDate":"2014-05-23","expirationDate":"2015-04-30","inactiveDate":"2015-06-29"},{"number":"512668","type":"Dumpster License - Private Property","status":"Active","businessName":"STARBUCKS CORPORATION (STARBUCKS COFFEE # 7840)","legalName":"STARBUCKS CORPORATION","address":"1500-42 MARKET ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2010-08-25","latestIssueDate":"2013-08-03","expirationDate":null,"inactiveDate":null},{"number":"514779","type":"Dumpster License - Private Property","status":"Active","businessName":"TONITA ATTN: BROOKS (REIT MANAGEMENT & RESEARCH)","legalName":"TONITA ATTN: BROOKS","address":"1500-42 MARKET ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2010-09-17","latestIssueDate":"2013-08-05","expirationDate":null,"inactiveDate":null},{"number":"498766","type":"Hazardous Materials","status":"Inactive","businessName":"REIT MANAGMENT & RESEARCH LLC","legalName":"REIT MANAGMENT & RESEARCH LLC","address":"1500-42 MARKET ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2010-10-27","latestIssueDate":"2010-10-27","expirationDate":"2011-12-31","inactiveDate":"2011-12-27"},{"number":"531977","type":"Food Preparing and Serving","status":"Inactive","businessName":"AKB MIR INC (CROWN CHICKEN OF MARKET ST)","legalName":"AKB MIR INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2011-05-02","latestIssueDate":"2011-05-02","expirationDate":"2012-04-30","inactiveDate":"2012-12-22"},{"number":"671704","type":"Public Garage / Parking Lot","status":"Closed","businessName":"LAZ PARKING MID-ATLANTIC LLC","legalName":"LAZ PARKING MID-ATLANTIC LLC","address":"1500-42 MARKET ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2015-08-11","latestIssueDate":"2017-04-20","expirationDate":"2017-08-31","inactiveDate":"2017-10-30"},{"number":"677248","type":"Dumpster License - Private Property","status":"Active","businessName":"SANTANDER BANK","legalName":"SANTANDER BANK","address":"1500-42 MARKET ST","revenueCode":"3230","rentalCategory":null,"units":null,"issuedDate":"2015-09-11","latestIssueDate":"2015-09-11","expirationDate":null,"inactiveDate":null},{"number":"689493","type":"Food Preparing and Serving","status":"Active","businessName":"NUTS TO YOU INC","legalName":"NUTS TO YOU INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2016-01-26","latestIssueDate":"2025-12-04","expirationDate":"2027-01-01","inactiveDate":null},{"number":"690017","type":"High Rise","status":"Inactive","businessName":"HRPT PROPERTIES TRUST (HUB PROPERTIES TRUST)","legalName":"HRPT PROPERTIES TRUST","address":"1500-42 MARKET ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2016-02-01","latestIssueDate":"2017-03-19","expirationDate":"2018-02-01","inactiveDate":"2018-04-02"},{"number":"693219","type":"Food Preparing and Serving","status":"Closed","businessName":"TRUST HOUSE SERVICES GROUP INC","legalName":"TRUST HOUSE SERVICES GROUP INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2016-03-01","latestIssueDate":"2017-06-19","expirationDate":"2018-03-01","inactiveDate":"2018-04-30"},{"number":"702336","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"PHMC 1500","legalName":"PHMC 1500","address":"1500-42 MARKET ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2016-05-19","latestIssueDate":"2018-05-17","expirationDate":"2019-05-18","inactiveDate":"2019-07-17"},{"number":"708071","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"THE AMERICAN PUB","legalName":"THE AMERICAN PUB","address":"1500-42 MARKET ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2016-07-15","latestIssueDate":"2019-07-16","expirationDate":"2020-07-14","inactiveDate":"2020-09-12"},{"number":"752395","type":"Public Garage / Parking Lot","status":"Active","businessName":"PARKWAY CORPORATION","legalName":"PARKWAY CORPORATION ","address":"1500-42 MARKET ST","revenueCode":"3371","rentalCategory":null,"units":null,"issuedDate":"2017-09-21","latestIssueDate":"2025-09-02","expirationDate":"2026-09-20","inactiveDate":null},{"number":"759276","type":"Annual Small Games Of Chance","status":"Inactive","businessName":"Benefits Data Trust","legalName":"Benefits Data Trust","address":"1500-42 MARKET ST","revenueCode":"3843","rentalCategory":null,"units":null,"issuedDate":"2017-12-07","latestIssueDate":"2017-12-07","expirationDate":"2018-12-06","inactiveDate":"2019-02-04"},{"number":"768753","type":"Food Preparing and Serving","status":"Expired","businessName":"OVATIONS FOOD SERVICES LP","legalName":"OVATIONS FOOD SERVICES LP","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2018-03-09","latestIssueDate":"2022-04-01","expirationDate":"2023-03-08","inactiveDate":null},{"number":"811824","type":"Food Preparing and Serving","status":"Inactive","businessName":"RP Dough 3 INC","legalName":"RP Dough 3 INC","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2019-05-08","latestIssueDate":"2025-05-01","expirationDate":"2026-05-07","inactiveDate":"2026-07-06"},{"number":"850600","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"NOBEL LEARNING COMMUNITIES INC","legalName":"NOBEL LEARNING COMMUNITIES INC","address":"1500-42 MARKET ST","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2020-09-04","latestIssueDate":"2020-09-04","expirationDate":"2021-09-03","inactiveDate":"2021-11-02"},{"number":"854238","type":"High Rise","status":"Active","businessName":"NG 1500 Market St LLC","legalName":"NG 1500 Market St LLC","address":"1500-42 MARKET ST","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2020-10-26","latestIssueDate":"2025-10-28","expirationDate":"2026-10-25","inactiveDate":null},{"number":"935573","type":"Food Preparing and Serving","status":"Closed","businessName":"Kwench Juice Cafe","legalName":"Kwench Juice Cafe","address":"1500-42 MARKET ST","revenueCode":"3120","rentalCategory":null,"units":null,"issuedDate":"2023-10-13","latestIssueDate":"2024-10-12","expirationDate":"2025-10-12","inactiveDate":null},{"number":"950057","type":"Food Establishment, Retail Permanent Location","status":"Active","businessName":"PUBLIC HEALTH MANAGEMENT CORP","legalName":"PUBLIC HEALTH MANAGEMENT CORP","address":"1500-42 MARKET ST","revenueCode":"3118","rentalCategory":null,"units":null,"issuedDate":"2024-04-26","latestIssueDate":"2026-04-30","expirationDate":"2027-04-25","inactiveDate":null}],"licenseActivity":[{"number":"950057","type":"Food Establishment, Retail Permanent Location","businessName":"PUBLIC HEALTH MANAGEMENT CORP","legalName":"PUBLIC HEALTH MANAGEMENT CORP","issuedDate":"2024-04-26","latestIssueDate":"2026-04-30","closureDate":null,"expirationDate":"2027-04-25","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"935573","type":"Food Preparing and Serving","businessName":"Kwench Juice Cafe","legalName":"Kwench Juice Cafe","issuedDate":"2023-10-13","latestIssueDate":"2024-10-12","closureDate":"2025-10-12","expirationDate":"2025-10-12","inactiveDate":null,"status":"Closed","statusLabel":"Closed","active":false},{"number":"854238","type":"High Rise","businessName":"NG 1500 Market St LLC","legalName":"NG 1500 Market St LLC","issuedDate":"2020-10-26","latestIssueDate":"2025-10-28","closureDate":null,"expirationDate":"2026-10-25","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"850600","type":"Food Preparing and Serving (30+ SEATS)","businessName":"NOBEL LEARNING COMMUNITIES INC","legalName":"NOBEL LEARNING COMMUNITIES INC","issuedDate":"2020-09-04","latestIssueDate":"2020-09-04","closureDate":"2021-11-02","expirationDate":"2021-09-03","inactiveDate":"2021-11-02","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"811824","type":"Food Preparing and Serving","businessName":"RP Dough 3 INC","legalName":"RP Dough 3 INC","issuedDate":"2019-05-08","latestIssueDate":"2025-05-01","closureDate":"2026-07-06","expirationDate":"2026-05-07","inactiveDate":"2026-07-06","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"768753","type":"Food Preparing and Serving","businessName":"OVATIONS FOOD SERVICES LP","legalName":"OVATIONS FOOD SERVICES LP","issuedDate":"2018-03-09","latestIssueDate":"2022-04-01","closureDate":"2023-03-08","expirationDate":"2023-03-08","inactiveDate":null,"status":"Expired","statusLabel":"Expired","active":false},{"number":"759276","type":"Annual Small Games Of Chance","businessName":"Benefits Data Trust","legalName":"Benefits Data Trust","issuedDate":"2017-12-07","latestIssueDate":"2017-12-07","closureDate":"2019-02-04","expirationDate":"2018-12-06","inactiveDate":"2019-02-04","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"752395","type":"Public Garage / Parking Lot","businessName":"PARKWAY CORPORATION","legalName":"PARKWAY CORPORATION ","issuedDate":"2017-09-21","latestIssueDate":"2025-09-02","closureDate":null,"expirationDate":"2026-09-20","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"708071","type":"Food Preparing and Serving (30+ SEATS)","businessName":"THE AMERICAN PUB","legalName":"THE AMERICAN PUB","issuedDate":"2016-07-15","latestIssueDate":"2019-07-16","closureDate":"2020-09-12","expirationDate":"2020-07-14","inactiveDate":"2020-09-12","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"702336","type":"Food Preparing and Serving (30+ SEATS)","businessName":"PHMC 1500","legalName":"PHMC 1500","issuedDate":"2016-05-19","latestIssueDate":"2018-05-17","closureDate":"2019-07-17","expirationDate":"2019-05-18","inactiveDate":"2019-07-17","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"693219","type":"Food Preparing and Serving","businessName":"TRUST HOUSE SERVICES GROUP INC","legalName":"TRUST HOUSE SERVICES GROUP INC","issuedDate":"2016-03-01","latestIssueDate":"2017-06-19","closureDate":"2018-04-30","expirationDate":"2018-03-01","inactiveDate":"2018-04-30","status":"Closed","statusLabel":"Inactive","active":false},{"number":"690017","type":"High Rise","businessName":"HRPT PROPERTIES TRUST (HUB PROPERTIES TRUST)","legalName":"HRPT PROPERTIES TRUST","issuedDate":"2016-02-01","latestIssueDate":"2017-03-19","closureDate":"2018-04-02","expirationDate":"2018-02-01","inactiveDate":"2018-04-02","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"689493","type":"Food Preparing and Serving","businessName":"NUTS TO YOU INC","legalName":"NUTS TO YOU INC","issuedDate":"2016-01-26","latestIssueDate":"2025-12-04","closureDate":null,"expirationDate":"2027-01-01","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"677248","type":"Dumpster License - Private Property","businessName":"SANTANDER BANK","legalName":"SANTANDER BANK","issuedDate":"2015-09-11","latestIssueDate":"2015-09-11","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"671704","type":"Public Garage / Parking Lot","businessName":"LAZ PARKING MID-ATLANTIC LLC","legalName":"LAZ PARKING MID-ATLANTIC LLC","issuedDate":"2015-08-11","latestIssueDate":"2017-04-20","closureDate":"2017-10-30","expirationDate":"2017-08-31","inactiveDate":"2017-10-30","status":"Closed","statusLabel":"Inactive","active":false},{"number":"531977","type":"Food Preparing and Serving","businessName":"AKB MIR INC (CROWN CHICKEN OF MARKET ST)","legalName":"AKB MIR INC","issuedDate":"2011-05-02","latestIssueDate":"2011-05-02","closureDate":"2012-12-22","expirationDate":"2012-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"498766","type":"Hazardous Materials","businessName":"REIT MANAGMENT & RESEARCH LLC","legalName":"REIT MANAGMENT & RESEARCH LLC","issuedDate":"2010-10-27","latestIssueDate":"2010-10-27","closureDate":"2011-12-27","expirationDate":"2011-12-31","inactiveDate":"2011-12-27","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"514779","type":"Dumpster License - Private Property","businessName":"TONITA ATTN: BROOKS (REIT MANAGEMENT & RESEARCH)","legalName":"TONITA ATTN: BROOKS","issuedDate":"2010-09-17","latestIssueDate":"2013-08-05","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"512668","type":"Dumpster License - Private Property","businessName":"STARBUCKS CORPORATION (STARBUCKS COFFEE # 7840)","legalName":"STARBUCKS CORPORATION","issuedDate":"2010-08-25","latestIssueDate":"2013-08-03","closureDate":null,"expirationDate":null,"inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"495501","type":"Food Establishment, Retail Permanent Location","businessName":"SHAILESH N TILVAWALA","legalName":"SHAILESH N TILVAWALA","issuedDate":"2010-03-12","latestIssueDate":"2014-05-23","closureDate":"2015-06-29","expirationDate":"2015-04-30","inactiveDate":"2015-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"478201","type":"Food Preparing and Serving (30+ SEATS)","businessName":"CLOTHESPIN ENTERPRISES LLC (THE AMERICAN PUB)","legalName":"CLOTHESPIN ENTERPRISES LLC","issuedDate":"2009-07-02","latestIssueDate":"2014-04-08","closureDate":"2015-06-29","expirationDate":"2015-04-30","inactiveDate":"2015-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"452457","type":"Food Establishment, Retail Permanent Location","businessName":"ABHAY & BINA V SHETH (ANAR NEWS)","legalName":"ABHAY & BINA V SHETH","issuedDate":"2008-07-28","latestIssueDate":"2015-07-03","closureDate":"2016-06-29","expirationDate":"2016-04-30","inactiveDate":"2016-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"425651","type":"Food Preparing and Serving","businessName":"NEW LIVING INC (RAINDROP CAFE)","legalName":"NEW LIVING INC","issuedDate":"2007-10-05","latestIssueDate":"2012-03-15","closureDate":"2012-12-22","expirationDate":"2012-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"284819","type":"Public Garage / Parking Lot","businessName":"CENTRAL PARKING SYSTEMS OF PA INC","legalName":"CENTRAL PARKING SYSTEMS OF PA INC","issuedDate":"2005-01-03","latestIssueDate":"2013-04-06","closureDate":"2013-12-16","expirationDate":"2013-12-31","inactiveDate":"2013-12-16","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"200747","type":"Food Establishment, Retail Permanent Location","businessName":"JAYSHREE & KIRIT DESAI","legalName":"JAYSHREE & KIRIT DESAI","issuedDate":"2004-09-16","latestIssueDate":"2006-06-30","closureDate":"2008-07-28","expirationDate":"2007-04-30","inactiveDate":"2008-07-28","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"207705","type":"Food Preparing and Serving","businessName":"STARBUCKS CORPORATION (STARBUCKS COFFEE # 7840)","legalName":"STARBUCKS CORPORATION","issuedDate":"2004-09-02","latestIssueDate":"2026-05-04","closureDate":null,"expirationDate":"2027-04-30","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true},{"number":"209699","type":"Food Preparing and Serving (30+ SEATS)","businessName":"PHILADELPHIA DAKOTAS INC","legalName":"PHILADELPHIA DAKOTAS INC","issuedDate":"2004-08-26","latestIssueDate":"2004-08-26","closureDate":"2012-12-22","expirationDate":"2005-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"200807","type":"Food Establishment, Retail Permanent Location","businessName":"SUB STAT SOFT PRETZEL FACTORY","legalName":"SUB STAT SOFT PRETZEL FACTORY","issuedDate":"2004-06-18","latestIssueDate":"2004-06-18","closureDate":"2012-12-22","expirationDate":"2006-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"299157","type":"High Rise","businessName":"REIT MANAGEMENT & RESEARCH LLC","legalName":"REIT MANAGEMENT & RESEARCH LLC","issuedDate":"2004-05-26","latestIssueDate":"2014-05-06","closureDate":"2015-06-29","expirationDate":"2015-04-30","inactiveDate":"2015-06-29","status":"Closed","statusLabel":"Inactive","active":false},{"number":"199976","type":"Food Establishment, Retail Permanent Location","businessName":"FABER COE & GREGG OF PA INC (PHILLY NEWS NOW)","legalName":"FABER COE & GREGG OF PA INC","issuedDate":"2004-05-20","latestIssueDate":"2009-04-22","closureDate":"2012-12-22","expirationDate":"2010-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"200228","type":"Food Establishment, Retail Permanent Location","businessName":"EXPRESSIONS 11 CARDS AND GIFTS","legalName":"EXPRESSIONS 11 CARDS AND GIFTS","issuedDate":"2004-05-16","latestIssueDate":"2010-01-05","closureDate":"2012-12-22","expirationDate":"2010-04-30","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"206484","type":"Food Preparing and Serving","businessName":"APS I INC","legalName":"APS I INC","issuedDate":"2004-04-30","latestIssueDate":"2018-04-16","closureDate":"2019-06-29","expirationDate":"2019-04-30","inactiveDate":"2019-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"200797","type":"Food Establishment, Retail Permanent Location","businessName":"GERTRUDE HAWK CHOCOLATES INC","legalName":"GERTRUDE HAWK CHOCOLATES INC","issuedDate":"2002-10-29","latestIssueDate":"2002-10-29","closureDate":"2003-04-30","expirationDate":"2003-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"202671","type":"Food Preparing and Serving","businessName":"AMY ENTERPIRSES INC","legalName":"AMY ENTERPIRSES INC","issuedDate":"2002-04-11","latestIssueDate":"2002-04-11","closureDate":"2003-04-30","expirationDate":"2003-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"205991","type":"Food Preparing and Serving","businessName":"KAWEJO INC","legalName":"KAWEJO INC","issuedDate":"2001-06-07","latestIssueDate":"2001-06-07","closureDate":"2002-04-30","expirationDate":"2002-04-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"record-pressure","level":"elevated","title":"Records to verify together","summary":"More than one separately dated public record deserves a current-status check.","evidence":["36 open L&I violations","failed L&I inspection activity in 2021, 2022, 2023, 2024, 2025, 2026"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."},{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["9 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Appeal #ZP-2024-001368: Completed · Granted with conditions; related permit ZP-2024-001368. Use permit #58881: COMPLETED. The history also contains “PERMB- FINAL PRE-CO INSP.”","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"48 permits not marked completed: 66312 (Expired), 145761 (Expired), 169114 (Expired), 189595 (Issued), 201232 (Issued). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"36 open L&I violations","finding":"227 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"96 failed, 120 passed, and 8 CLOSED investigation outcomes are in the fetched history; the latest dated visit was FAILED on Mar 24, 2026.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"verify","title":"A filed system certification needs status or date verification","finding":"Facade Report: Safe with Repair through Mar 30, 2028; Special Hazards Certification: Certified through Jul 13, 2027; Fire Alarm Certification: Certified through Jun 23, 2027; Sprinkler Certification: Certified through Oct 7, 2026; Emergency and Standby Power Systems Certification: Certified through May 9, 2027","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Confirm the result, expiration, and L&I acceptance before treating the filing as current.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Preparing and Serving #205991: Inactive; Food Preparing and Serving #202671: Inactive; Food Establishment, Retail Permanent Location #200797: Inactive; Food Preparing and Serving #206484: Inactive since Jun 29, 2019","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}