{"asOf":"2026-07-28T17:39:11.148Z","block":"6100-6199 TACONY ST","blockUrl":"https://philadelphia.blockreport.homes/block/6100-6199-tacony-st","address":"6101 TACONY ST","parcelNumber":"884178000","source":"https://property.phila.gov/?p=884178000","ownerType":"investor","kind":"industrial","isHouse":false,"home":false,"commercial":true,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"LB1","buildingCodeNew":"401","buildingClass":"IND LIGHT MFG MASONRY+OTH","buildingClassNew":"MANUFACTURING/PROCESSING","useLabel":"Industrial","owner":"NEWMAN & COMPANY INC","coOwner":null,"marketValue":6410000,"landAssessment":1282000,"improvementAssessment":5128000,"livableArea":200313,"yearBuilt":1930,"lastSale":{"price":1,"date":"2022-08-01T04:00:00Z"},"openViolations":0,"violations":[{"number":"1596607","date":"2009-11-03","code":"FC-703.4/1","title":"FIRE-TEST HORIZ/VERT/ROLL DOOR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596609","date":"2009-11-03","code":"FC-2703.2/5","title":"HAZMAT-REM DEF CON+TNK REP/DIS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596608","date":"2009-11-03","code":"FC-901.4/1","title":"OBTAIN PERMIT EXTEN SPRKLR SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596606","date":"2009-11-03","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596611","date":"2009-11-03","code":"FC-912.4/1","title":"FIRE CONNECT SIGN-NEW CONST","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596610","date":"2009-11-03","code":"FC-105.7/3","title":"F+C LIQ-PERMIT REQ'D REMOV TNK","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5265338","date":"2019-12-10","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5265337","date":"2019-12-10","code":"CP-305","title":"RUBBISH/GARBAGE EXTERIOR-OWNER","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5265336","date":"2019-12-10","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2021-002344","date":"2021-01-13","code":"PM15-308.1","title":"RUBBISH & GARBAGE","status":"COMPLIED","resolutionDate":"2021-01-26","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2022-086438","date":"2022-11-16","code":"PM15-108.1","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":"2024-01-10","resolution":"COMPLIED - PERMIT OBTAINED"},{"number":"VI-2022-086439","date":"2022-11-16","code":"PM15-304.1(H)","title":"ROOF DEFICIENCIES","status":"COMPLIED","resolutionDate":"2024-01-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2022-086440","date":"2022-11-16","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":"2024-01-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2023-079342","date":"2023-10-11","code":"F-105.6.1.8","title":"HAZARDOUS MATERIALS\n","status":"COMPLIED","resolutionDate":"2024-05-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2024-029574","date":"2024-04-25","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029575","date":"2024-04-25","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029576","date":"2024-04-25","code":"F-507.5.2","title":"FIRE HYDRANT INSPECTION, TESTING, MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029577","date":"2024-04-25","code":"F-5003.4.1","title":"STORAGE OF SAFETY DATA SHEETS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029562","date":"2024-04-25","code":"F-1104.3","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029560","date":"2024-04-25","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029559","date":"2024-04-25","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029558","date":"2024-04-25","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029557","date":"2024-04-25","code":"F-5003.5.1","title":"MARKING OF CONTAINERS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029561","date":"2024-04-25","code":"F-5003.5.1","title":"MARKING OF CONTAINERS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029563","date":"2024-04-25","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029564","date":"2024-04-25","code":"F-1103.4.2","title":"THREE TO FIVE STORIES\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029573","date":"2024-04-25","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"}],"violationCases":[{"number":"219653","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2009-11-05","completedDate":"2010-04-05","violations":[{"number":"1596607","date":"2009-11-03","code":"FC-703.4/1","title":"FIRE-TEST HORIZ/VERT/ROLL DOOR","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596609","date":"2009-11-03","code":"FC-2703.2/5","title":"HAZMAT-REM DEF CON+TNK REP/DIS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596608","date":"2009-11-03","code":"FC-901.4/1","title":"OBTAIN PERMIT EXTEN SPRKLR SYS","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596606","date":"2009-11-03","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596611","date":"2009-11-03","code":"FC-912.4/1","title":"FIRE CONNECT SIGN-NEW CONST","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1596610","date":"2009-11-03","code":"FC-105.7/3","title":"F+C LIQ-PERMIT REQ'D REMOV TNK","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"718630","type":"STANDARD","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2019-12-10","completedDate":"2019-12-18","violations":[{"number":"5265338","date":"2019-12-10","code":"CP-312A","title":"HIGH WEEDS-CUT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5265337","date":"2019-12-10","code":"CP-305","title":"RUBBISH/GARBAGE EXTERIOR-OWNER","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"5265336","date":"2019-12-10","code":"CP-01","title":"CLIP VIOLATION NOTICE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2021-003096","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"CLIP","status":"CLOSED","createdDate":"2021-01-13","completedDate":"2021-01-26","violations":[{"number":"VI-2021-002344","date":"2021-01-13","code":"PM15-308.1","title":"RUBBISH & GARBAGE","status":"COMPLIED","resolutionDate":"2021-01-26","resolution":"COMPLIED - OWNER REPAIR"}]},{"number":"CF-2022-115905","type":"NOTICE OF VIOLATION","priority":"UNSAFE","responsibility":"CSU INVESTIGATOR","status":"CLOSED","createdDate":"2022-11-16","completedDate":"2024-01-10","violations":[{"number":"VI-2022-086438","date":"2022-11-16","code":"PM15-108.1","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":"2024-01-10","resolution":"COMPLIED - PERMIT OBTAINED"},{"number":"VI-2022-086439","date":"2022-11-16","code":"PM15-304.1(H)","title":"ROOF DEFICIENCIES","status":"COMPLIED","resolutionDate":"2024-01-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"},{"number":"VI-2022-086440","date":"2022-11-16","code":"A-304.1/1","title":"ARCHITECT/ENGINEER SERVICES","status":"COMPLIED","resolutionDate":"2024-01-10","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2023-106299","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2023-10-12","completedDate":"2024-05-14","violations":[{"number":"VI-2023-079342","date":"2023-10-11","code":"F-105.6.1.8","title":"HAZARDOUS MATERIALS\n","status":"COMPLIED","resolutionDate":"2024-05-13","resolution":"COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED"}]},{"number":"CF-2024-031581","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"FIRE SAFETY INVESTIGATOR","status":"CLOSED","createdDate":"2024-04-16","completedDate":"2024-08-12","violations":[{"number":"VI-2024-029574","date":"2024-04-25","code":"F-903.5","title":"SUPPRESSION SYSTEM TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029575","date":"2024-04-25","code":"F-901.6.4","title":"PERIODIC TESTING\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029576","date":"2024-04-25","code":"F-507.5.2","title":"FIRE HYDRANT INSPECTION, TESTING, MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029577","date":"2024-04-25","code":"F-5003.4.1","title":"STORAGE OF SAFETY DATA SHEETS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029562","date":"2024-04-25","code":"F-1104.3","title":"EXIT SIGN ILLUMINATION\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029560","date":"2024-04-25","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029559","date":"2024-04-25","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029558","date":"2024-04-25","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029557","date":"2024-04-25","code":"F-5003.5.1","title":"MARKING OF CONTAINERS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029561","date":"2024-04-25","code":"F-5003.5.1","title":"MARKING OF CONTAINERS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029563","date":"2024-04-25","code":"F-901.6","title":"INSPECTION, TESTING & MAINTENANCE\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029564","date":"2024-04-25","code":"F-1103.4.2","title":"THREE TO FIVE STORIES\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"},{"number":"VI-2024-029573","date":"2024-04-25","code":"F-5003.5","title":"HAZARD IDENTIFICATION SIGNS\n","status":"COMPLIED","resolutionDate":"2024-08-07","resolution":"COMPLIED - OWNER REPAIR"}]}],"violYears":[{"y":2009,"n":6,"worst":null},{"y":2019,"n":3,"worst":null},{"y":2021,"n":1,"worst":null},{"y":2022,"n":3,"worst":"UNSAFE STRUCTURE"},{"y":2023,"n":1,"worst":null},{"y":2024,"n":13,"worst":null}],"investigations":[{"caseNumber":"219653","date":"2009-11-03","type":"CI INSP","status":"FAILED"},{"caseNumber":"219653","date":"2010-02-18","type":"CI INSP","status":"FAILED"},{"caseNumber":"219653","date":"2010-04-01","type":"CI INSP","status":"PASSED"},{"caseNumber":"CF-2021-003096","date":"2021-01-13","type":null,"status":"FAILED"},{"caseNumber":"CF-2021-003096","date":"2021-01-26","type":null,"status":"PASSED"},{"caseNumber":"CF-2022-115905","date":"2022-11-16","type":null,"status":"FAILED"},{"caseNumber":"CF-2023-106299","date":"2023-10-12","type":null,"status":"FAILED"},{"caseNumber":"CF-2022-115905","date":"2024-01-10","type":null,"status":"PASSED"},{"caseNumber":"CF-2024-031581","date":"2024-04-26","type":null,"status":"FAILED"},{"caseNumber":"CF-2023-106299","date":"2024-05-14","type":null,"status":"PASSED"},{"caseNumber":"CF-2024-031581","date":"2024-08-12","type":null,"status":"PASSED"}],"inspYears":[{"y":2009,"fails":1,"passes":0},{"y":2010,"fails":1,"passes":1},{"y":2021,"fails":1,"passes":1},{"y":2022,"fails":1,"passes":0},{"y":2023,"fails":1,"passes":0},{"y":2024,"fails":1,"passes":3}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":40.01431390620391,"lng":-75.05271907775891,"geom":{"type":"Polygon","coordinates":[[[-75.053748363,40.013746493],[-75.053570925,40.013838789],[-75.054221351,40.014580599],[-75.053719204,40.014841503],[-75.052273209,40.01544218],[-75.051163065,40.01416791],[-75.053197938,40.013118718],[-75.053748363,40.013746493]]]},"liDistrict":"EAST","certifications":[{"number":"BC-2022-001831","type":"Fire Alarm Certification","inspectionDate":"2022-02-03","result":"Certified","expirationDate":"2023-02-03","buildingId":"1276568"},{"number":"BC-2023-003891","type":"Sprinkler Certification","inspectionDate":"2022-06-12","result":"Certified","expirationDate":"2023-06-12","buildingId":"1277152"},{"number":"BC-2023-003889","type":"Sprinkler Certification","inspectionDate":"2022-06-12","result":"Certified","expirationDate":"2023-06-12","buildingId":"1276568"},{"number":"BC-2023-003888","type":"Sprinkler Certification","inspectionDate":"2022-06-12","result":"Certified","expirationDate":"2023-06-12","buildingId":"1276569"},{"number":"BC-2024-011772","type":"Sprinkler Certification","inspectionDate":"2023-07-26","result":"Certified","expirationDate":"2024-07-26","buildingId":"1277152"},{"number":"BC-2024-012762","type":"Fire Alarm Certification","inspectionDate":"2023-09-06","result":"Certified","expirationDate":"2024-09-06","buildingId":"1277152"},{"number":"BC-2023-021332","type":"Fire Alarm Certification","inspectionDate":"2023-10-05","result":"Certified","expirationDate":"2024-10-05","buildingId":"1276568"},{"number":"BC-2024-012758","type":"Fire Alarm Certification","inspectionDate":"2023-10-05","result":"Certified","expirationDate":"2024-10-05","buildingId":"1276568"},{"number":"BC-2024-012761","type":"Fire Alarm Certification","inspectionDate":"2023-10-05","result":"Certified","expirationDate":"2024-10-05","buildingId":"1276569"},{"number":"BC-2023-021337","type":"Fire Alarm Certification","inspectionDate":"2023-10-05","result":"Certified","expirationDate":"2024-10-05","buildingId":"1276569"},{"number":"BC-2024-022594","type":"Fire Alarm Certification","inspectionDate":"2024-02-01","result":"Certified","expirationDate":"2025-02-01","buildingId":"1277152"},{"number":"BC-2024-012810","type":"Sprinkler Certification","inspectionDate":"2024-04-27","result":"Certified","expirationDate":"2025-04-27","buildingId":"1277152"},{"number":"BC-2024-022298","type":"Sprinkler Certification","inspectionDate":"2024-06-25","result":"Certified","expirationDate":"2025-06-25","buildingId":"1277152"},{"number":"BC-2024-027801","type":"Fire Alarm Certification","inspectionDate":"2024-10-07","result":"Certified","expirationDate":"2025-10-07","buildingId":"1276569"},{"number":"BC-2024-027805","type":"Fire Alarm Certification","inspectionDate":"2024-10-07","result":"Certified","expirationDate":"2025-10-07","buildingId":"1276568"},{"number":"BC-2025-003188","type":"Fire Alarm Certification","inspectionDate":"2025-02-03","result":"Certified","expirationDate":"2026-02-03","buildingId":"1276568"},{"number":"BC-2026-008219","type":"Sprinkler Certification","inspectionDate":"2025-07-21","result":"Certified","expirationDate":"2026-07-21","buildingId":"1277152"},{"number":"BC-2026-008217","type":"Sprinkler Certification","inspectionDate":"2025-07-21","result":"Certified","expirationDate":"2026-07-21","buildingId":"1276569"},{"number":"BC-2026-008214","type":"Sprinkler Certification","inspectionDate":"2025-07-21","result":"Certified","expirationDate":"2026-07-21","buildingId":"1276568"},{"number":"BC-2025-019638","type":"Fire Alarm Certification","inspectionDate":"2025-07-25","result":"Certified","expirationDate":"2026-07-25","buildingId":"1276568"},{"number":"BC-2025-020021","type":"Fire Alarm Certification","inspectionDate":"2025-07-25","result":"Certified","expirationDate":"2026-07-25","buildingId":"1276568"},{"number":"BC-2025-026846","type":"Fire Alarm Certification","inspectionDate":"2025-10-13","result":"Certified","expirationDate":"2026-10-13","buildingId":"1276568"},{"number":"BC-2026-003525","type":"Fire Alarm Certification","inspectionDate":"2026-02-09","result":"Certified","expirationDate":"2027-02-09","buildingId":"1276568"}],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19135","beds":null,"baths":null,"stories":null,"lotArea":358934,"zoning":"I3","grade":"C","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"6101 TACONY ST, PHILADELPHIA PA, 19135","mailOut":false,"appeals":[{"type":"RB_LIRB","grounds":"NEWMAN OBJECTS TO THE ISSUANCE BY AIR MANAGEMENT RELATING TO A FAILURE TO SURRENDER OZONE SEASON NOx ALLOWANCES IN 2007 AND THREE SEPARATE VIOLATIONS FROM A SINGLE SET OF CIRCUMSTANCES.","status":"OPEN","outcome":"Withdrawn","date":"2010-06-15","number":"7956","relatedPermit":null},{"type":"RB_LIRB","grounds":"NEWMAN OBJECTS TO THE FACTUAL AND LEGAL CHARACTERIZATIONS OF THE ASSERTED VIOLATIONS.NEWMAN HAS REQUESTED A MEETING TO DISCUSS THE NOV WITH AMS.","status":"CLOSED","outcome":"Withdrawn","date":"2018-07-10","number":"33935","relatedPermit":null},{"type":"LIRB-H Environmental Health","grounds":"Continued at least 90 days","status":"Closed","outcome":"Continued","date":"2026-03-27","number":"HA-2025-004813","relatedPermit":null}],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":2737500,"taxable":2737500,"land":1040900,"improvement":1696600,"taxableLand":1040900,"taxableImprovement":1696600,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":2737500,"taxable":2737500,"land":1040900,"improvement":1696600,"taxableLand":1040900,"taxableImprovement":1696600,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":3713700,"taxable":3713700,"land":1076973,"improvement":2636727,"taxableLand":1076973,"taxableImprovement":2636727,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":3713800,"taxable":3713800,"land":1435736,"improvement":2278064,"taxableLand":1435736,"taxableImprovement":2278064,"exemptLand":0,"exemptImprovement":0},{"y":2020,"v":3737900,"taxable":3737900,"land":1445053,"improvement":2292847,"taxableLand":1445053,"taxableImprovement":2292847,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":3737900,"taxable":3737900,"land":1445053,"improvement":2292847,"taxableLand":1445053,"taxableImprovement":2292847,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":3737900,"taxable":3737900,"land":1445053,"improvement":2292847,"taxableLand":1445053,"taxableImprovement":2292847,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":4406900,"taxable":4406900,"land":881380,"improvement":3525520,"taxableLand":881380,"taxableImprovement":3525520,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":4406900,"taxable":4406900,"land":881380,"improvement":3525520,"taxableLand":881380,"taxableImprovement":3525520,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":4607200,"taxable":4607200,"land":1382160,"improvement":3225040,"taxableLand":1382160,"taxableImprovement":3225040,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":4607200,"taxable":4607200,"land":1382160,"improvement":3225040,"taxableLand":1382160,"taxableImprovement":3225040,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":6410000,"taxable":6410000,"land":1282000,"improvement":5128000,"taxableLand":1282000,"taxableImprovement":5128000,"exemptLand":0,"exemptImprovement":0}],"taxNow":64492,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"477587","date":"2013-06-14","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-08-28","scope":"ROOF RECOVERING, TPO MEMBRANE SYSTEM (COMMERCIAL)"},{"number":"487491","date":"2013-08-06","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2013-08-28","scope":"ROOF RECOVERING, EPDM SYSTEM - ADDITIONAL WORK BEING DONE TO FINISH ROOF (SEE BP 477587) - COMMERCIAL PROPERTY"},{"number":"614676","date":"2015-06-03","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2015-09-23","scope":"REMOVE EXISTING ROOF COVERING AND REPLACE WITH NEW TPO MEMBRANE. ROOF MEMBRANE COVERING TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS. THE NEW ROOF COVERING SHALL PROVIDE A WEATHERTIGHT ROOF SYSTEM. **POST THIS PERMIT** **POST THE PROJECT INFORMATION SIGN**"},{"number":"785703","date":"2017-05-22","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-06-28","scope":"RECOVER THE EXISTING CORRUGATED METAL ROOF BY MECHANICALLY ATTACHED 1 LAYER OF 1/2\" HD POLY INSULATION AND MECHANICALLY ATTACHED .060 WHITE TPO ROOF MEMBRANE"},{"number":"SP-2020-000440","date":"2020-11-09","work":"Sitework with Onsite Utility Services","type":"Site / Utility Permit","description":"Site / Utility Permit","status":"Expired","completedDate":"2022-05-16","scope":"Construction of Subsurface Detention Bed, Roof Drains and drainage pipes, manholes and inlets in the asphalt parking area between the commercial buildings. Detention Bed will utilize pumping system to harvest stormwater as desired and the rest will overflow into the Sanitary Sewer underneath Comly Street."},{"number":"PP-2020-011716","date":"2021-02-08","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2023-10-16","scope":"Construction of Subsurface Detention Bed, Roof Drains and drainage pipes, manholes and inlets in the asphalt parking area between the commercial buildings. Detention Bed will utilize pumping system to harvest stormwater as desired and the rest will overflow into the Sanitary Sewer underneath Comly Street."},{"number":"CP-2022-006909","date":"2022-12-15","work":"Addition and/or Alteration","type":"Building","description":"Commercial Building Permit","status":"Completed","completedDate":"2024-01-10","scope":"MAKE SAFE PERMIT TO COMPLY WITH CASE VIOLATION CF-2022-115905 TO INCLUDE ROOF/WALL REPAIRS PER APPROVED PLANS, ENIGINEERS REPORT AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION."},{"number":"SP-2023-001212","date":"2024-02-06","work":"Sitework with Onsite Utility Services","type":"Site / Utility Permit","description":"Site / Utility Permit","status":"Issued","completedDate":null,"scope":"FOR SITEWORK AND ONSITE UTILITY TO ACCOMMODATE THE UPDATED STORMWATER DRAINAGE SYSTEM. ALL WORK PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK."},{"number":"PP-2024-001666","date":"2024-02-08","work":"New Construction or Additions","type":"Plumbing","description":"Plumbing Permit","status":"Issued","completedDate":null,"scope":"Plumbing Permit for combo SP-2023-001212"},{"number":"GM-2025-009504","date":"2025-10-08","work":"Roof Covering Replacement","type":"General Permit Minor","description":"General Permit Minor","status":"Completed","completedDate":"2025-12-30","scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."},{"number":"GM-2026-002536","date":"2026-04-02","work":"Roof Covering Replacement","type":"General Permit Minor","description":"General Permit Minor","status":"Issued","completedDate":null,"scope":"For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work."}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2022,"k":"viol","w":"3 L&I violations incl UNSAFE STRUCTURE"},{"y":2022,"k":"insp","w":"Inspection failed"},{"y":2022,"k":"permit","w":"Addition and/or Alteration"},{"y":2023,"k":"viol","w":"L&I violation"},{"y":2023,"k":"insp","w":"Inspection failed"},{"y":2024,"k":"permit","w":"Sitework with Onsite Utility Services"},{"y":2024,"k":"permit","w":"New Construction or Additions"},{"y":2024,"k":"viol","w":"13 L&I violations"},{"y":2024,"k":"insp","w":"L&I: 1 failed, 3 passed"},{"y":2025,"k":"permit","w":"Roof Covering Replacement"},{"y":2026,"k":"appeal","w":"Appeal continued"},{"y":2026,"k":"permit","w":"Roof Covering Replacement"}],"rented":false,"licenses":[{"number":"286105","type":"Hazardous Materials","status":"Active","businessName":"NEWMAN & COMPANY INC","legalName":"NEWMAN & COMPANY INC","address":"6101 TACONY ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2004-12-03","latestIssueDate":"2026-01-05","expirationDate":"2026-12-31","inactiveDate":null},{"number":"286760","type":"Hazardous Materials","status":"Inactive","businessName":"UNITED STATES RECYCLING INC","legalName":"UNITED STATES RECYCLING INC","address":"6101 TACONY ST","revenueCode":"3335","rentalCategory":null,"units":null,"issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","expirationDate":"2009-06-30","inactiveDate":null}],"licenseActivity":[{"number":"286760","type":"Hazardous Materials","businessName":"UNITED STATES RECYCLING INC","legalName":"UNITED STATES RECYCLING INC","issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","closureDate":"2009-06-30","expirationDate":"2009-06-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"286105","type":"Hazardous Materials","businessName":"NEWMAN & COMPANY INC","legalName":"NEWMAN & COMPANY INC","issuedDate":"2004-12-03","latestIssueDate":"2026-01-05","closureDate":null,"expirationDate":"2026-12-31","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true}],"businessLicenseSourceDate":"2026-07-27","signals":[{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["4 permit events since 2023","1 zoning/board appeal since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"5 permits not marked completed: SP-2020-000440 (Expired), PP-2020-011716 (Expired), SP-2023-001212 (Issued), PP-2024-001666 (Issued), GM-2026-002536 (Issued). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"An unsafe-building history still deserves the repair file","finding":"The fetched record shows 0 open and 27 historical violations across 6 cases.","why":"The aggregate currently shows zero open violations, so a historical unsafe/imminently-dangerous row is not a current hazard finding. The repair or demolition permit, final inspection, and case closure are the evidence that resolves the former designation.","action":"Review the Make Safe/repair permit, final inspection, and case closure.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"building-certifications","level":"attention","title":"A life-safety certification appears expired","finding":"Fire Alarm Certification: Certified through Feb 9, 2027; Sprinkler Certification: Certified through Jul 21, 2026","why":"Fire-protection certifications apply to the named system and inspection period only; they are not a whole-building safety certificate. Philadelphia generally requires annual sprinkler, standpipe, fire-alarm, special-hazard, and emergency-power inspections where those systems exist.","action":"Request the correction/reinspection and current filed certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"6 failed, 5 passed, and 0 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Aug 12, 2024.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Hazardous Materials #286760: Inactive","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}