{"asOf":"2026-07-26T09:37:23.931Z","block":"400-499 WASHINGTON AVE","blockUrl":"https://philadelphia.blockreport.homes/block/400-499-washington-ave","address":"401-41 WASHINGTON AVE","parcelNumber":"886760905","source":"https://property.phila.gov/?p=886760905","ownerType":"investor","kind":"multi-family","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":true,"institutional":true,"buildingCode":"CC0","buildingCodeNew":"828","buildingClass":"APTS 100+ UNITS MASONRY","buildingClassNew":"APTS - GARDEN","useLabel":"Apartment building","owner":"PHILADELPHIA HOUSING AUTH","coOwner":null,"marketValue":8143500,"landAssessment":2035800,"improvementAssessment":6107700,"livableArea":194392,"yearBuilt":1975,"lastSale":{"price":4,"date":"2016-12-20T05:00:00Z"},"openViolations":6,"violations":[{"number":"1161521","date":"2008-11-17","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPEXCP","resolutionDate":null,"resolution":null},{"number":"1272747","date":"2009-03-18","code":"FC-914.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1272745","date":"2009-03-18","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1272746","date":"2009-03-18","code":"FC-907.10/2","title":"FA-AUDIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307661","date":"2011-02-22","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307659","date":"2011-02-22","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307660","date":"2011-02-22","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307663","date":"2011-02-22","code":"FC-912.2/1","title":"FIRE CONNECT SIGN-EXIST BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307662","date":"2011-02-22","code":"FC-409.5/1","title":"SHELTER DRILL CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307658","date":"2011-02-22","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2763710","date":"2013-01-17","code":"PM-305.3/3","title":"INT S-CEILING REPAIR/MAINT SAN","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737147","date":"2013-03-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737149","date":"2013-03-11","code":"PM-102.1/1","title":"LICENSE-RES MFD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737148","date":"2013-03-11","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3057128","date":"2014-01-09","code":"PM-407.2/9","title":"ELEC-RECEPTABLE DEFECTIVE-RES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3057127","date":"2014-01-09","code":"PM-303.4/1","title":"INT A-RODENT BURROWS, ELIMINAT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3860143","date":"2015-06-29","code":"PM-307.1/10","title":"WALL LOOSE/MISS BRICKS","status":"ERROR","resolutionDate":null,"resolution":null},{"number":"3860144","date":"2015-06-29","code":"PM-307.1/11","title":"WALL DETERIORATED","status":"ERROR","resolutionDate":null,"resolution":null},{"number":"3786660","date":"2015-10-13","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3786659","date":"2015-10-13","code":"FC-901.7/1","title":"FIRE PROT SYS MAINTENANCE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"VI-2025-016522","date":"2025-03-26","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-016521","date":"2025-03-26","code":"F-1103.9","title":"CARBON MONOXIDE ALARMS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-016520","date":"2025-03-26","code":"PM15-403.5","title":"VENTILATION- DRYER EXHAUST","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-017888","date":"2025-03-31","code":"PM15-304.15","title":"EXTERIOR STRUCTURE DOORS","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-017889","date":"2025-03-31","code":"PM15-309.1","title":"PEST ELIMINATION INFESTATION","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-017890","date":"2025-03-31","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"OPEN","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"185584","type":"HAZARDOUS","priority":"HAZARDOUS","responsibility":"HCEU","status":"CLOSED","createdDate":"2008-11-18","completedDate":"2008-11-25","violations":[{"number":"1161521","date":"2008-11-17","code":"A.CNE.000","title":"COULD NOT ENTER","status":"COMPEXCP","resolutionDate":null,"resolution":null}]},{"number":"194251","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2009-03-18","completedDate":"2009-10-15","violations":[{"number":"1272747","date":"2009-03-18","code":"FC-914.1/5","title":"ANNUAL CERT STANDBY/EMERG LITE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1272745","date":"2009-03-18","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"1272746","date":"2009-03-18","code":"FC-907.10/2","title":"FA-AUDIBILITY","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"267066","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2011-02-23","completedDate":"2016-05-16","violations":[{"number":"2307661","date":"2011-02-22","code":"FC-409.4/1","title":"SHELTER PLN-EMPLY TRNG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307659","date":"2011-02-22","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307660","date":"2011-02-22","code":"FC-409.1/1","title":"SHELTER PLN-REQ¿D","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307663","date":"2011-02-22","code":"FC-912.2/1","title":"FIRE CONNECT SIGN-EXIST BLDG","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307662","date":"2011-02-22","code":"FC-409.5/1","title":"SHELTER DRILL CONDUCT","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2307658","date":"2011-02-22","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"371856","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2013-03-07","completedDate":"2013-06-25","violations":[{"number":"2763710","date":"2013-01-17","code":"PM-305.3/3","title":"INT S-CEILING REPAIR/MAINT SAN","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"372241","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2013-03-12","completedDate":"2013-04-29","violations":[{"number":"2737147","date":"2013-03-11","code":"A-000.0/10","title":"VIOL C&I MESSAGE","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737149","date":"2013-03-11","code":"PM-102.1/1","title":"LICENSE-RES MFD","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"2737148","date":"2013-03-11","code":"FC-408.12/1","title":"HIRISE-PAY HIRISE FEE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"415925","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2014-01-09","completedDate":"2014-02-27","violations":[{"number":"3057128","date":"2014-01-09","code":"PM-407.2/9","title":"ELEC-RECEPTABLE DEFECTIVE-RES","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3057127","date":"2014-01-09","code":"PM-303.4/1","title":"INT A-RODENT BURROWS, ELIMINAT","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"488271","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2015-06-29","completedDate":"2016-07-13","violations":[{"number":"3860143","date":"2015-06-29","code":"PM-307.1/10","title":"WALL LOOSE/MISS BRICKS","status":"ERROR","resolutionDate":null,"resolution":null},{"number":"3860144","date":"2015-06-29","code":"PM-307.1/11","title":"WALL DETERIORATED","status":"ERROR","resolutionDate":null,"resolution":null}]},{"number":"506540","type":"STANDARD","priority":"STANDARD","responsibility":"CI","status":"CLOSED","createdDate":"2015-10-15","completedDate":"2016-01-19","violations":[{"number":"3786660","date":"2015-10-13","code":"FC-915.1/4","title":"ANNUAL CERT FIRE SUPP","status":"COMPLIED","resolutionDate":null,"resolution":null},{"number":"3786659","date":"2015-10-13","code":"FC-901.7/1","title":"FIRE PROT SYS MAINTENANCE","status":"COMPLIED","resolutionDate":null,"resolution":null}]},{"number":"CF-2025-022110","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PUBLIC PROPERTY","status":"IN VIOLATION","createdDate":"2025-03-26","completedDate":null,"violations":[{"number":"VI-2025-016522","date":"2025-03-26","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-016521","date":"2025-03-26","code":"F-1103.9","title":"CARBON MONOXIDE ALARMS\n","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-016520","date":"2025-03-26","code":"PM15-403.5","title":"VENTILATION- DRYER EXHAUST","status":"OPEN","resolutionDate":null,"resolution":null}]},{"number":"CF-2025-023727","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PUBLIC PROPERTY","status":"IN VIOLATION","createdDate":"2025-03-31","completedDate":null,"violations":[{"number":"VI-2025-017888","date":"2025-03-31","code":"PM15-304.15","title":"EXTERIOR STRUCTURE DOORS","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-017889","date":"2025-03-31","code":"PM15-309.1","title":"PEST ELIMINATION INFESTATION","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-017890","date":"2025-03-31","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"OPEN","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2008,"n":1,"worst":null},{"y":2009,"n":3,"worst":null},{"y":2011,"n":6,"worst":null},{"y":2013,"n":4,"worst":null},{"y":2014,"n":2,"worst":null},{"y":2015,"n":4,"worst":null},{"y":2025,"n":6,"worst":null}],"investigations":[{"caseNumber":"72953","date":"2006-07-28","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"72953","date":"2008-11-17","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"185584","date":"2008-11-17","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"185584","date":"2008-11-24","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"194251","date":"2009-03-18","type":"CI INSP","status":"FAILED"},{"caseNumber":"194251","date":"2009-10-14","type":"CI INSP","status":"PASSED"},{"caseNumber":"267066","date":"2011-02-22","type":"CI INSP","status":"FAILED"},{"caseNumber":"267066","date":"2011-04-15","type":"CI INSP","status":"FAILED"},{"caseNumber":"267066","date":"2011-06-17","type":"CI INSP","status":"CLOSED"},{"caseNumber":"267066","date":"2011-10-06","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"267066","date":"2011-12-13","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"267066","date":"2012-01-26","type":"PRECOURT","status":"PASSED"},{"caseNumber":"371856","date":"2013-01-17","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"372241","date":"2013-03-11","type":"CI INSP","status":"FAILED"},{"caseNumber":"371856","date":"2013-04-12","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"372241","date":"2013-04-24","type":"CI INSP","status":"PASSED"},{"caseNumber":"371856","date":"2013-06-21","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"415925","date":"2014-01-09","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"415925","date":"2014-02-27","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"488271","date":"2015-06-29","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"488271","date":"2015-07-29","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"488271","date":"2015-08-31","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"488271","date":"2015-09-30","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"506540","date":"2015-10-13","type":"CI INSP","status":"FAILED"},{"caseNumber":"506541","date":"2015-10-13","type":"CI INSP","status":"CLOSED"},{"caseNumber":"488271","date":"2015-11-30","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"488271","date":"2015-11-30","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"506540","date":"2015-12-02","type":"CI INSP","status":"FAILED"},{"caseNumber":"488271","date":"2015-12-30","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"506540","date":"2016-01-15","type":"CI INSP","status":"PASSED"},{"caseNumber":"488271","date":"2016-02-01","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"488271","date":"2016-03-04","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"488271","date":"2016-07-12","type":"CSUINITIAL","status":"PASSED"},{"caseNumber":"CF-2025-022110","date":"2025-03-27","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-023727","date":"2025-03-31","type":null,"status":"FAILED"}],"inspYears":[{"y":2006,"fails":1,"passes":0},{"y":2008,"fails":1,"passes":0},{"y":2009,"fails":1,"passes":1},{"y":2011,"fails":2,"passes":0},{"y":2012,"fails":0,"passes":1},{"y":2013,"fails":3,"passes":2},{"y":2014,"fails":1,"passes":1},{"y":2015,"fails":9,"passes":0},{"y":2016,"fails":2,"passes":2},{"y":2025,"fails":2,"passes":0}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.93583382240861,"lng":-75.15125855759784,"geom":{"type":"Polygon","coordinates":[[[-75.150309376,39.936850123],[-75.150856282,39.934451333],[-75.152202943,39.934829486],[-75.151672714,39.937200208],[-75.150309376,39.936850123]]]},"liDistrict":"CENTRAL EAST","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":false,"permits":true,"licenses":true},"zip":"19147","beds":null,"baths":null,"stories":null,"lotArea":353627,"zoning":"RM2","grade":"C+","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"2013 RIDGE AVE, PHILADELPHIA PA, 19121","mailOut":false,"appeals":[],"taxYears":[],"taxNet":0,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":4117500,"taxable":4117500,"land":1768135,"improvement":2349365,"taxableLand":1768135,"taxableImprovement":2349365,"exemptLand":0,"exemptImprovement":0},{"y":2017,"v":4117500,"taxable":4117500,"land":1768135,"improvement":2349365,"taxableLand":1768135,"taxableImprovement":2349365,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":6917500,"taxable":6917500,"land":1729375,"improvement":5188125,"taxableLand":1729375,"taxableImprovement":5188125,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":7832400,"taxable":0,"land":1958100,"improvement":5874300,"taxableLand":0,"taxableImprovement":0,"exemptLand":1958100,"exemptImprovement":5874300},{"y":2020,"v":7832400,"taxable":0,"land":1958100,"improvement":5874300,"taxableLand":0,"taxableImprovement":0,"exemptLand":1958100,"exemptImprovement":5874300},{"y":2021,"v":7832400,"taxable":0,"land":1958100,"improvement":5874300,"taxableLand":0,"taxableImprovement":0,"exemptLand":1958100,"exemptImprovement":5874300},{"y":2022,"v":7832400,"taxable":0,"land":1958100,"improvement":5874300,"taxableLand":0,"taxableImprovement":0,"exemptLand":1958100,"exemptImprovement":5874300},{"y":2023,"v":7832400,"taxable":0,"land":1958100,"improvement":5874300,"taxableLand":0,"taxableImprovement":0,"exemptLand":1958100,"exemptImprovement":5874300},{"y":2024,"v":7832400,"taxable":0,"land":1958100,"improvement":5874300,"taxableLand":0,"taxableImprovement":0,"exemptLand":1958100,"exemptImprovement":5874300},{"y":2025,"v":8143500,"taxable":0,"land":2035875,"improvement":6107625,"taxableLand":0,"taxableImprovement":0,"exemptLand":2035875,"exemptImprovement":6107625},{"y":2026,"v":8143500,"taxable":0,"land":2035875,"improvement":6107625,"taxableLand":0,"taxableImprovement":0,"exemptLand":2035875,"exemptImprovement":6107625},{"y":2027,"v":8143500,"taxable":0,"land":2035800,"improvement":6107700,"taxableLand":0,"taxableImprovement":0,"exemptLand":2035800,"exemptImprovement":6107700}],"taxNow":0,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"121612","date":"2007-12-14","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2008-02-15","scope":"INSTALL 2 - 30AMP JCIRCUITS FROM 120VOLT HOUSE PANEL FOR 6 NEW OUTLETS, INSTALL 10 CAT5, 10 GAUGE PLENUM CABLES FOR COMPUTERS LONGEST DROP 125' AS PER 2005 NEC (SOUTH DISTRICT)"},{"number":"490623","date":"2013-08-21","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2014-03-18","scope":"REPLACE 2 VALVES IN PIT FOR WATER DEPT (APTS)"},{"number":"740805","date":"2016-12-14","work":"Use","type":"ZP_USE","description":"USE PERMIT","status":"COMPLETED","completedDate":"2016-12-14","scope":"DOCUMENTATION OF EXISTING USE FOR (22) TWO STORY STRUCTURES WITH 182 UNTIS."},{"number":"746516","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-10-12","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (4) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS,"},{"number":"745838","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-08-21","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (2) TWO FAMILY DWELLING UNITS"},{"number":"746517","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-10-12","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (4) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746518","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-09-25","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746519","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-09-22","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746520","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-10-02","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (2) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746521","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-10-27","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746522","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746523","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-06-12","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (2) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746524","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (2) TWO FAMILY DWELLING UNITS"},{"number":"746525","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (3) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746526","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (4) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746527","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-12-19","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (2) TWO FAMILY DWELLING UNITS"},{"number":"746528","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (4) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746529","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (3) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746530","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746531","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-15","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746532","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (2) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746533","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-02","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746534","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-07-25","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746535","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-15","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (2) SINGLE DWELLING UNITS AND (4) TWO FAMILY DWELLING UNITS"},{"number":"746536","date":"2016-12-29","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2017-11-14","scope":"LEVEL 1 ALTERATIONS TO EXITING STRUCTURES-INTERIOR DRYWALL-63SF OF DRYWALL REPLACEMENT. (1425 SF.)VINYL SIDING REPLACEMENT/ 725 SF OF ROOF REPLACEMENT-ALL WORK TO CONFORM WITH EZ STANDARDS. (6) SINGLE DWELLING UNITS AND (2) TWO FAMILY DWELLING UNITS"},{"number":"766986","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-05-11","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNITS 300,308,320 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 302,304,306,310,312,314,316,318"},{"number":"766988","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-04-13","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNIT 335 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 321,323,325,327,329,331,333"},{"number":"766987","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-04-03","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNIT 315 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS301,303,305,307,309,311,313"},{"number":"766990","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-05-05","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNITS 960,970 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 962,964,966,968,"},{"number":"766989","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-03-23","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNITS 3411,351 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 343,345,347,349"},{"number":"766991","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-05-03","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNITS 972,990 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 974,976,978,980,982,984,986,988"},{"number":"766992","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-04-20","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNITS 1000,1018 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 1002,1004,1006,1008,1010,1012,1014,1016"},{"number":"766993","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-04-07","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNITS 1034 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 1020,1022,1024,1026,1028,1030,1032"},{"number":"766994","date":"2017-03-16","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-05-18","scope":"REPLACEMENT OF OLD UNITS WITH IN MOD: FURNACE EQUIPMENT NAT GAS DIRECT VENT GOODMAN 40,000 BTU 96% AFUE A/C R410A, GSX160 18 16SEER 18,000 BTU WITHIN UNITS 953,963 AND NAT GAS DIRECT VENT 40,000 96% AFUE A/C R 410A, GSX16024 16 SEER 24,000 BTU WITH IN UNITS 955,957,959,961"},{"number":"781170","date":"2017-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-20","scope":"REPLACEMENT OF OLD UNITS WITH MOD: GOODMAN EQIPMENT FURNACE NAT GAS, DIRECT VENT GMEC 960402 40,000BTU 96% AGU, A/C R410A GSX, 16018 16SEER 18,000BTUWITH IN UNITS: 931 AND FURNACE WAT GAS, DIRECT VENT, GMEC 960402 40000BTU 96% AFUE, A/C R410A,GSX 16024 16 SEER 24,000BTU WITH UNITS 921,923,925,927,929"},{"number":"781155","date":"2017-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-05-25","scope":"REPLACEMENT OF OLD UNITS WITHIN MOD\" GOODMAN EQUIPMENT FURNACE NAT GAS, DIRECT VENT GMBC 960402 40,000BTU 96% AFUE,A/C R410AGSX 16018 16SEER 18,000BTU WITH IN UNITS: 933, 9512 AND FURNACE WATGAS, DIRECT VENT GMEC 9604022 40,000BTU 96 AFUE, A/C NAT GAS, DUIRECT VENT GMEC 960402 40,000BTU 96% AFUFE. A/C R410A GSX 16024, 16 SEER 24,000BTU WITH UNITS 935, 937, 939,941,943,945,947,949"},{"number":"781172","date":"2017-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-16","scope":"REPLACEMENT OF OLD UNITS WITH MOD: GOODMAN EQIPMENT FURNACE NAT GAS, DIRECT VENT GMEC 960402 40,000BTU 96% AGU, A/C R410A GSX, 16018 16SEER 18,000BTUWITH IN UNITS: 905, 919 AND FURNACE WAT GAS, DIRECT VENT, GMEC 960402 40000BTU 96% AFUE, A/C R410A,GSX 16024 16 SEER 24,000BTU WITH UNITS 907, 909, 911, 913, 915, 917"},{"number":"781247","date":"2017-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-05","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES ( HIGH EFFIENCY AC UNITS) FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"781253","date":"2017-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-07-20","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES ( HIGH EFFIENCY AC UNITS) FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"781251","date":"2017-05-05","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-12-19","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES ( HIGH EFFIENCY AC UNITS) FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS."},{"number":"782788","date":"2017-05-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.NATURAL GAS, DIRECT VENT, 40000 BTU, 96% AFUE, AC, 16SEER, 24000 BTU (4 UNITS)"},{"number":"782796","date":"2017-05-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-06-09","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.NATURAL GAS, DIRECT VENT, 40000 BTU, 96% AFUE, AC, 16SEER, 24000 BTU (6 UNITS)"},{"number":"787121","date":"2017-05-26","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-07-20","scope":"REPLACEMENT OF 15 WATER CLOSET,15 LAVY SINKS, 9 BATHTUBS 9 KITCHEN SINKS AND 8 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2008"},{"number":"799025","date":"2017-07-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-10","scope":"REPLACEMENT OF OLS UNITS WITH MOD. GOODMAN EQUIPMAN.. GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE, DIRECT VENT 96%AFUE, 40000BTU, AIR CONDITION SGX16024 16SEER, R410A, 24.000BTU WITH IN UNITS 420, 422,424,428,430,432. PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO EXISTING DUCT SYSTEM."},{"number":"799032","date":"2017-07-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-21","scope":"REPLACENT OF OLD UNITS WITH IN KOD. GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE DIRECT VENT 96%AFUE, 40,000BTU. AIR CONDITION GSX 16018 16SEER, RA104A, 18,000 BTU WITH IN UNITS 460. AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE, DIRECT VENT, 96 5AFUE, 40,000BTU AIR CONDITION GSX16024 16SEER R410A, 24,000BTU WITHIN UNITSS PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO EXISTING DUCT SYSTEM."},{"number":"799034","date":"2017-07-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-12-19","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO EXISTING DUCT SYSTEM."},{"number":"799050","date":"2017-07-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-20","scope":"REPLACENT OF OLD UNITS WITH IN KOD. GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE DIRECT VENT 96%AFUE, 40,000BTU. AIR CONDITION GSX 16018 16SEER, RA104A, 18,000 BTU WITH IN UNITS 400. AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE, DIRECT VENT, 96 5AFUE, 40,000BTU AIR CONDITION GSX16024 16SEER R410A, 24,000BTU WITHIN UNITSS #402,404,406,408,410,410,412,414.PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO EXISTING DUCT SYSTEM."},{"number":"799051","date":"2017-07-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-12","scope":"REPLACENT OF OLD UNITS WITH IN KOD. GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE DIRECT VENT 96%AFUE, 40,000BTU. AIR CONDITION GSX 16018 16SEER, RA104A, 18,000 BTU WITH IN UNITS 456. AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE, DIRECT VENT, 96 5AFUE, 40,000BTU AIR CONDITION GSX16024 16SEER R410A, 24,000BTU WITHIN UNITSS #442,444,446,448,450,452,454PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO EXISTING DUCT SYSTEM."},{"number":"799052","date":"2017-07-12","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-12","scope":"REPLACENT OF OLD UNITS WITH IN KOD. GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE DIRECT VENT 96%AFUE, 40,000BTU. AIR CONDITION GSX 16018 16SEER, RA104A, 18,000 BTU WITH IN UNITS905919. AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNANCE, DIRECT VENT, 96 5AFUE, 40,000BTU AIR CONDITION GSX16024 16SEER R410A, 24,000BTU WITHIN UNITSS #4907,909,913,915,917PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO EXISTING DUCT SYSTEM."},{"number":"801125","date":"2017-07-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-10-20","scope":"REPLACEMENT OF 14 WATER CLOSETS, 14 LAVY SINKS, 8 BATHTUBS 8 KITCHEN SINKS AND 8 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"801126","date":"2017-07-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-10-12","scope":"REPLACEMENT OF 12 WATER CLOSETS, 12 LAVY SINKS, 10 BATHTUBS 8 KITCHEN SINKS AND 8 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"801127","date":"2017-07-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-08-21","scope":"REPLACEMENT OF 14 WATER CLOSETS, 14 LAVY SINKS, 8 BATHTUBS 8 KITCHEN SINKS AND 8 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"801128","date":"2017-07-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-11-09","scope":"REPLACEMENT OF 10 WATER CLOSETS, 10 LAVY SINKS, 9 BATHTUBS 7 KITCHEN SINKS AND 7 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"801129","date":"2017-07-19","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-11-03","scope":"REPLACEMENT OF 8 WATER CLOSETS, 8 LAVY SINKS, 6 BATHTUBS 6 KITCHEN SINKS AND 6 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"803430","date":"2017-07-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-21","scope":"REPLACE WITH NO ADDITIONAL WIRING WITH IN A 8 UNIT BUILDING WITH LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"803434","date":"2017-07-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-08-21","scope":"REPLACE WITH NO ADDITIONAL WIRING WITH IN A 6 UNIT BUILDING WITH LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"803435","date":"2017-07-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"REPLACE WITH NO ADDITIONAL WIRING WITH IN A 8 UNIT BUILDING WITH LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"809060","date":"2017-08-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-25","scope":"REPLACEMENT OF OLD UNITS WITHIN MOD: GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCT NAT GAS FURNACE, DIRECT VENT,96% 40,000 BTU, AIR CONDITION GSX16018 16 SEER, R410A, 18,000BTU WITHIN UNITS:921,939 AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNACE, DIRECT VENT,96%AFUE,40,00BTU, AIR CONDITION GSX16024 16SEER, R410A, 24,000BTU WITHIN UNITS:923,925,927,929,931,933,935,937"},{"number":"809062","date":"2017-08-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-22","scope":"REPLACEMENT OF OLD UNITS WITHIN MOD: GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCT NAT GAS FURNACE, DIRECT VENT,96% 40,000 BTU, AIR CONDITION GSX16018 16 SEER, R410A, 18,000BTU WITHIN UNITS:941,959 AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNACE, DIRECT VENT,96%AFUE,40,00BTU, AIR CONDITION GSX16024 16SEER, R410A, 24,000BTU WITHIN UNITS:943,945,947,949,951,953,955,957"},{"number":"809063","date":"2017-08-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-02","scope":"REPLACEMENT OF OLD UNITS WITHIN MOD: GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCT NAT GAS FURNACE, DIRECT VENT,96% 40,000 BTU, AIR CONDITION GSX16018 16 SEER, R410A, 18,000BTU WITHIN UNITS:961,971 AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNACE, DIRECT VENT,96%AFUE,40,00BTU, AIR CONDITION GSX16024 16SEER, R410A, 24,000BTU WITHIN UNITS:963,965,967,969"},{"number":"809064","date":"2017-08-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-27","scope":"REPLACEMENT OF OLD UNITS WITHIN MOD: GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCT NAT GAS FURNACE, DIRECT VENT,96% 40,000 BTU, AIR CONDITION GSX16018 16 SEER, R410A, 18,000BTU WITHIN UNITS:973,991 AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNACE, DIRECT VENT,96%AFUE,40,00BTU, AIR CONDITION GSX16024 16SEER, R410A, 24,000BTU WITHIN UNITS:975,977,979,981,983,985,987,989"},{"number":"809065","date":"2017-08-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-02-16","scope":"REPLACEMENT OF OLD UNITS WITHIN MOD: GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCT NAT GAS FURNACE, DIRECT VENT,96% 40,000 BTU, AIR CONDITION GSX16018 16 SEER, R410A, 18,000BTU WITHIN UNITS:960,970 AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNACE, DIRECT VENT,96%AFUE,40,00BTU, AIR CONDITION GSX16024 16SEER, R410A, 24,000BTU WITHIN UNITS:962,964,966,968"},{"number":"809066","date":"2017-08-17","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-02-16","scope":"REPLACEMENT OF OLD UNITS WITHIN MOD: GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCT NAT GAS FURNACE, DIRECT VENT,96% 40,000 BTU, AIR CONDITION GSX16018 16 SEER, R410A, 18,000BTU WITHIN UNITS:940,958 AND GMEC 960402 HIGH EFFICIENCY NAT GAS FURNACE, DIRECT VENT,96%AFUE,40,00BTU, AIR CONDITION GSX16024 16SEER, R410A, 24,000BTU WITHIN UNITS:942,944,946,948,950,952,954,956"},{"number":"810120","date":"2017-08-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-05","scope":"REPLACE EXISTING OUTLETS WITH NEW TR OUTLETS,SWITCHES ENERGY EFFICIENT LIGHT FIXTURES AND SMOKE DETECTORS *REPLACEMENT OF EQUIPMENT IN KIND* PER 2008 NEC (MULTI FAMILY)"},{"number":"810121","date":"2017-08-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-13","scope":"REPLACE EXISTING OUTLETS WITH NEW TR OUTLETS,SWITCHES ENERGY EFFICIENT LIGHT FIXTURES AND SMOKE DETECTORS *REPLACEMENT OF EQUIPMENT IN KIND* PER 2008 NEC (MULTI FAMILY)"},{"number":"810122","date":"2017-08-21","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-15","scope":"REPLACE EXISTING OUTLETS WITH NEW TR OUTLETS,SWITCHES ENERGY EFFICIENT LIGHT FIXTURES AND SMOKE DETECTORS *REPLACEMENT OF EQUIPMENT IN KIND* PER 2008 NEC (MULTI FAMILY)"},{"number":"812245","date":"2017-08-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-10-12","scope":"REPLACEMENT OF 12 WATER CLOSETS, 12 LAVY SINKS, 10 BATHTUBS 8 KITCHEN SINKS AND 8 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"812246","date":"2017-08-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-09-25","scope":"REPLACEMENT OF 16 WATER CLOSETS, 16 LAVY SINKS, 10 BATHTUBS 10 KITCHEN SINKS AND 10 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"812247","date":"2017-08-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-09-22","scope":"REPLACEMENT OF 16 WATER CLOSETS, 16 LAVY SINKS, 10 BATHTUBS 10 KITCHEN SINKS AND 10 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"812248","date":"2017-08-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-10-02","scope":"REPLACEMENT OF 8 WATER CLOSETS, 8 LAVY SINKS, 6 BATHTUBS 6 KITCHEN SINKS AND 6 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"812249","date":"2017-08-29","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-10-27","scope":"REPLACEMENT OF 16 WATER CLOSETS, 16 LAVY SINKS, 10 BATHTUBS 10 KITCHEN SINKS AND 10 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"814996","date":"2017-09-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-02","scope":"NO NEW WIRING INSTALLATIONS. REPLACE ONLY EXISTING OUTLETS WITH TR OUTLETS, SWITCHES, LIGHTS FIXTURES AND HARD WIRED SMOKE DETECTORS, REPLACE WITH NO ADD'L WIRING AS PER NEC 2008 SOUTH DISTRICT"},{"number":"814998","date":"2017-09-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-09-22","scope":"NO NEW WIRING INSTALLATIONS. REPLACE ONLY EXISTING OUTLETS WITH TR OUTLETS, SWITCHES, LIGHTS FIXTURES AND HARD WIRED SMOKE DETECTORS, REPLACE WITH NO ADD'L WIRING AS PER NEC 2008 SOUTH DISTRICT"},{"number":"815002","date":"2017-09-11","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-19","scope":"NO NEW WIRING INSTALLATIONS. REPLACE ONLY EXISTING OUTLETS WITH TR OUTLETS, SWITCHES, LIGHTS FIXTURES AND HARD WIRED SMOKE DETECTORS, REPLACE WITH NO ADD'L WIRING AS PER NEC 2008 SOUTH DISTRICT"},{"number":"821541","date":"2017-10-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-12-19","scope":"ONLY REMOVING EXISTING OUTLETS AND REPLACINGWITH TR OUTLETS, SWITCHES, LIGHT FIXTURES AND SMIK DEFUSERS"},{"number":"821537","date":"2017-10-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-03","scope":"ONLY REMOVING EXISTING OUTLETS AND REPLACINGWITH TR OUTLETS, SWITCHES, LIGHT FIXTURES AND SMIK DEFUSERS"},{"number":"821532","date":"2017-10-04","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-10-19","scope":"ONLY REMOVING EXISTING OUTLETS AND REPLACINGWITH TR OUTLETS, SWITCHES, LIGHT FIXTURES AND SMIK DEFUSERS"},{"number":"823014","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-03-23","scope":"PERMIT - DIRECT VENT HEATING APPARATUS & A/C APPLIANCES - FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. INSTALL GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCY NAT. GAS FURNACE, DIRECT VENT, 96% AFUE, 40,000 BTU, AIR CONDITIONER GSX16018 16 SEER, R410A, 18,000 BTU WITHIN UNIT 475, AND GMEC 960402 HIGH EFFICIENCY NAT. GAS FURNACE, DIRECT VENT, 96% AFUE, 40,000 BTU, AIR CONDITIONER GSX16024 16 SEER, R410A, 24,000 BTU WITHIN UNITS 461, 463, 465, 467, 469, 471, 473."},{"number":"823028","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-10-24","scope":"PERMIT - DIRECT VENT HEATING APPARATUS & A/C APPLIANCES - FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. INSTALL GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCY NAT. GAS FURNACE, DIRECT VENT, 96% AFUE, 40,000 BTU, AIR CONDITIONER GSX16024 16 SEER, R410A, 24,000 BTU WITHIN UNITS 441, 443, 445, 447, 449, 451, 453."},{"number":"823039","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-04-27","scope":"PERMIT - DIRECT VENT HEATING APPARATUS & A/C APPLIANCES - FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. INSTALL GOODMAN EQUIPMENT: GMEC 960402 HIGH EFFICIENCY NAT. GAS FURNACE, DIRECT VENT, 96% AFUE, 40,000 BTU, AIR CONDITIONER GSX16024 16 SEER, R410A, 24,000 BTU WITHIN UNITS 441, 443, 445, 447, 449, 451, 453; AND GMEC 960402 HIGH EFFICIENCY NAT. GAS FURNACE, DIRECT VENT, 96% AFUE, 40,000 BTU, AIR CONDITIONER GSX16018 16 SEER, R410A, 18,000 BTU WITHIN UNITS 976, 994."},{"number":"823069","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-20","scope":"1 HIGH EFFICENCY HEATER- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"823070","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-16","scope":"1 HIGH EFFICENCY HEATER- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"823067","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-06-14","scope":"1 HIGH EFFICENCY HEATER-FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"823106","date":"2017-10-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-12-22","scope":"REPLACEMENT WITH NO ADDITIONAL PIPING 16 WATER CLOSETS, 16 LAVY SINKS, 10 BATHTUBS 10 KITCHEN SINKS AND 10 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"823105","date":"2017-10-11","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-06-28","scope":"REPLACEMENT WITH NO ADDITIONAL PIPING 8 WATER CLOSETS, 8 LAVY SINKS, 6 BATHTUBS 6 KITCHEN SINKS AND 6 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"823139","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-02-02","scope":"1 HIGH EFFICENCY HEATER- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"823146","date":"2017-10-11","work":"Mechanical","type":"BP_MECH","description":"MECHANICAL PERMIT","status":"COMPLETED","completedDate":"2018-07-16","scope":"1 HIGH EFFICENCY HEATER- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS."},{"number":"826163","date":"2017-10-23","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-12-22","scope":"REPLACEMENT WITH NO ADDITIONAL PIPING 10 WATER CLOSETS, 10 LAVY SINKS, 9 BATHTUBS 7 KITCHEN SINKS AND 7 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004."},{"number":"826164","date":"2017-10-23","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2017-12-22","scope":"REPLACEMENT WITH NO ADDITIONAL PIPING 16 WATER CLOSETS, 16 LAVY SINKS, 10 BATHTUBS 10 KITCHEN SINKS AND 10 GAS WATER HEATERS - THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"828896","date":"2017-11-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-22","scope":"REPLACE WITH NO ADDITIONAL WIRING WITHIN BUILDING LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"828895","date":"2017-11-01","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-11-03","scope":"REPLACE WITH NO ADDITIONAL WIRING WITHIN BUILDING LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"830238","date":"2017-11-07","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-12-19","scope":"REPLACE WITH NO ADDITIONAL WIRING IN KIND LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"830311","date":"2017-11-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-11-09","scope":"REPLACEMENT OF: 14 W-CLOSETS, 14-LAVS, 10 BATHTUBS, 8 KITCHEN SINKS, AND 8 GAS W-HEATERS."},{"number":"830310","date":"2017-11-07","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-07-16","scope":"REPLACEMENT OF: 16W-CLOSETS, 16LAVS, 10 BATHTUBS, 10 KITCHEN SINKS, AND 10 GAS W-HEATERS."},{"number":"833296","date":"2017-11-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-04-13","scope":"REPLACE 16-WATER CLOSETS, 16-LAVS, 10-BATHTUBS, 10-KITCHEN SINKS, 1-LAUNDRY & 10-WATER HEATERS THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"833295","date":"2017-11-17","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-11-09","scope":"REPLACE 12-WATER CLOSETS, 12-LAVS, 10-BATHTUBS, 8-KITCHEN SINKS, 1-LAUNDRY & 8-WATER HEATERS THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"836742","date":"2017-12-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":null,"scope":"INSTALL NEW OUTLETS SWITCHES LIGHT AND SMOKE DETECTORS AS PER 2008 NEC."},{"number":"836743","date":"2017-12-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2017-12-15","scope":"INSTALL NEW OUTLETS SWITCHES LIGHT AND SMOKE DETECTORS AS PER 2008 NEC."},{"number":"836745","date":"2017-12-05","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-09-17","scope":"INSTALL NEW OUTLETS SWITCHES LIGHT AND SMOKE DETECTORS AS PER 2008 NEC."},{"number":"844167","date":"2018-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-03-16","scope":"REPLACE 12-WATER CLOSETS, 12-LAVS, 8-BATHTUB, 8-KITCHEN SINKS & 8-GAS WATER HEATERS THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"844172","date":"2018-01-10","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2018-02-02","scope":"REPLACE 14-WATER CLOSETS, 14-LAVS, 10-BATHTUB, 8-KITCHEN SINKS & 8-GAS WATER HEATERS THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004"},{"number":"845624","date":"2018-01-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-19","scope":"REPLACE WITH NO ADDITIONAL WIRING WITH IN A 8 UNIT BUILDING WITH LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"845625","date":"2018-01-16","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2018-01-26","scope":"REPLACE WITH NO ADDITIONAL WIRING WITH IN A 8 UNIT BUILDING WITH LIGHT FIXTURES, SMOKES DETECTORS, LIGHT SWITCHES AND TAMPER RESISTANT OUTLETS AS PER NEC 2008 (SOUTH DISTRICT)"},{"number":"EP-2023-007515","date":"2023-09-25","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2023-12-20","scope":"Upgrade existing fire alarm system. One for one replacement AS PER NEC 2017"}],"storyTag":"Improved","storyDelta":null,"timeline":[{"y":2017,"k":"permit","w":"Plumbing"},{"y":2017,"k":"permit","w":"Plumbing"},{"y":2017,"k":"permit","w":"Electrical"},{"y":2017,"k":"permit","w":"Electrical"},{"y":2017,"k":"permit","w":"Electrical"},{"y":2018,"k":"permit","w":"Plumbing"},{"y":2018,"k":"permit","w":"Plumbing"},{"y":2018,"k":"permit","w":"Electrical"},{"y":2018,"k":"permit","w":"Electrical"},{"y":2023,"k":"permit","w":"Addition and/or Alteration"},{"y":2025,"k":"viol","w":"6 L&I violations"},{"y":2025,"k":"insp","w":"Inspection failed ×2"}],"rented":false,"licenses":[{"number":"243989","type":"Rental","status":"Inactive","businessName":"SOUTHWARK PLAZA LIMITED PTNRSP","legalName":"SOUTHWARK PLAZA LIMITED PTNRSP","address":"401-41 WASHINGTON AVE","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":1,"issuedDate":"2004-06-07","latestIssueDate":"2005-06-08","expirationDate":"2006-02-28","inactiveDate":"2012-12-22"},{"number":"209057","type":"Food Preparing and Serving (30+ SEATS)","status":"Inactive","businessName":"PHILA HOUSING AUTHORITY","legalName":"PHILA HOUSING AUTHORITY","address":"401-41 WASHINGTON AVE","revenueCode":"3121","rentalCategory":null,"units":null,"issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","expirationDate":"2009-06-30","inactiveDate":null},{"number":"351990","type":"Rental","status":"Inactive","businessName":"SOUTHWARK PLAZA LTD PARTNERSHIP (C/O COHEN & WILLWORTH PC)","legalName":"SOUTHWARK PLAZA LTD PARTNERSHIP","address":"401-41 WASHINGTON AVE","revenueCode":"3202","rentalCategory":null,"units":165,"issuedDate":"2006-01-12","latestIssueDate":"2006-01-12","expirationDate":"2006-02-28","inactiveDate":"2012-12-22"},{"number":"378548","type":"Rental","status":"Closed","businessName":"SOUTHWARK PLAZA LIMITED PTNRSP (INTERSTATE REALTY)","legalName":"SOUTHWARK PLAZA LIMITED PTNRSP","address":"401-41 WASHINGTON AVE","revenueCode":"3202","rentalCategory":null,"units":484,"issuedDate":"2006-07-24","latestIssueDate":"2016-04-21","expirationDate":"2017-02-28","inactiveDate":null},{"number":"552192","type":"High Rise","status":"Inactive","businessName":"SOUTHWARK PLAZA LIMITED PTNRSP (INTERSTATE REALTY)","legalName":"SOUTHWARK PLAZA LIMITED PTNRSP","address":"401-41 WASHINGTON AVE","revenueCode":"3629","rentalCategory":null,"units":null,"issuedDate":"2012-01-12","latestIssueDate":"2015-09-17","expirationDate":"2016-04-30","inactiveDate":"2016-06-29"},{"number":"732664","type":"Rental","status":"Inactive","businessName":"COURTYARD PRESERVATION LP","legalName":"COURTYARD PRESERVATION LP","address":"401-41 WASHINGTON AVE","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":470,"issuedDate":"2017-03-23","latestIssueDate":"2025-03-25","expirationDate":"2026-03-22","inactiveDate":"2026-05-21"}],"licenseActivity":[{"number":"732664","type":"Rental","businessName":"COURTYARD PRESERVATION LP","legalName":"COURTYARD PRESERVATION LP","issuedDate":"2017-03-23","latestIssueDate":"2025-03-25","closureDate":"2026-05-21","expirationDate":"2026-03-22","inactiveDate":"2026-05-21","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"552192","type":"High Rise","businessName":"SOUTHWARK PLAZA LIMITED PTNRSP (INTERSTATE REALTY)","legalName":"SOUTHWARK PLAZA LIMITED PTNRSP","issuedDate":"2012-01-12","latestIssueDate":"2015-09-17","closureDate":"2016-06-29","expirationDate":"2016-04-30","inactiveDate":"2016-06-29","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"378548","type":"Rental","businessName":"SOUTHWARK PLAZA LIMITED PTNRSP (INTERSTATE REALTY)","legalName":"SOUTHWARK PLAZA LIMITED PTNRSP","issuedDate":"2006-07-24","latestIssueDate":"2016-04-21","closureDate":"2017-02-28","expirationDate":"2017-02-28","inactiveDate":null,"status":"Closed","statusLabel":"Closed","active":false},{"number":"351990","type":"Rental","businessName":"SOUTHWARK PLAZA LTD PARTNERSHIP (C/O COHEN & WILLWORTH PC)","legalName":"SOUTHWARK PLAZA LTD PARTNERSHIP","issuedDate":"2006-01-12","latestIssueDate":"2006-01-12","closureDate":"2012-12-22","expirationDate":"2006-02-28","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false},{"number":"209057","type":"Food Preparing and Serving (30+ SEATS)","businessName":"PHILA HOUSING AUTHORITY","legalName":"PHILA HOUSING AUTHORITY","issuedDate":"2005-01-28","latestIssueDate":"2005-01-28","closureDate":"2009-06-30","expirationDate":"2009-06-30","inactiveDate":null,"status":"Inactive","statusLabel":"Inactive","active":false},{"number":"243989","type":"Rental","businessName":"SOUTHWARK PLAZA LIMITED PTNRSP","legalName":"SOUTHWARK PLAZA LIMITED PTNRSP","issuedDate":"2004-06-07","latestIssueDate":"2005-06-08","closureDate":"2012-12-22","expirationDate":"2006-02-28","inactiveDate":"2012-12-22","status":"Inactive","statusLabel":"Inactive","active":false}],"businessLicenseSourceDate":"2026-07-25","signals":[{"kind":"record-pressure","level":"elevated","title":"Records to verify together","summary":"More than one separately dated public record deserves a current-status check.","evidence":["6 open L&I violations","failed L&I inspection activity in 2025"],"caveat":"A screening signal, not a foreclosure prediction. Tax entries are historical and must be verified with Philadelphia Revenue."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #740805: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"violations","level":"attention","title":"6 open L&I violations","finding":"26 violation rows are retained in the City ledger.","why":"Open notices can accrue fees, block permits or license renewal, and move to court or collection. Standard initial notices generally have a 30-day appeal window; unsafe or imminently-dangerous notices have a much shorter window.","action":"Read the notice—not only the summary status—and confirm reinspection, fees, and appeal posture with L&I.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"22 failed, 7 passed, and 6 CLOSED investigation outcomes are in the fetched history; the latest dated visit was FAILED on Mar 31, 2025.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"verify","title":"A fire-system permit exists, but no annual certification matched","finding":"1 fire/suppression-related permit matched; the fetched BIN certification feed returned no row.","why":"Installed systems in mixed-use and larger buildings generally require periodic certification, but applicability and limited-area exceptions vary. A missing BIN/address join is not proof of a compliance failure.","action":"Confirm what system was installed and whether a current annual certificate is required and filed.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"business-license","level":"verify","title":"A historical business license is not current operating authority","finding":"Food Preparing and Serving (30+ SEATS) #209057: Inactive; High Rise #552192: Inactive since Jun 29, 2016","why":"A license record proves the licensed activity existed at that time. An inactive or expired license does not establish that the business still operates—or that it may legally reopen under the same use.","action":"If business income matters, verify the current tenant, use registration, and active license in eCLIPSE.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/licenses/business-licenses/"},{"id":"full-tax-exemption","level":"verify","title":"OPA shows a full exemption; its legal basis is unverified","finding":"OPA currently marks the land and building assessment fully tax-exempt; BlockReport does not receive the exemption determination or basis.","why":"Full OPA exemptions can have different legal bases, including government, religious, charitable/institutional, veteran, or other treatment. The current owner/use record is not a buyer’s tax forecast.","action":"Confirm the exact exemption basis, buyer eligibility, and next tax-year treatment directly with OPA.","url":"https://www.phila.gov/departments/office-of-property-assessment/tax-exemptions-and-abatements/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as multi-family. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}