{"asOf":"2026-07-25T16:12:34.926Z","block":"3000-3099 MASTER ST","blockUrl":"https://philadelphia.blockreport.homes/block/3000-3099-master-st","address":"3000 MASTER ST","parcelNumber":"886906021","source":"https://property.phila.gov/?p=886906021","ownerType":"investor","kind":"multi-family","isHouse":false,"home":false,"commercial":false,"residential":false,"taxExempt":false,"institutional":false,"buildingCode":"CB0","buildingCodeNew":"804","buildingClass":"APTS 51-100 UNITS MASONRY","buildingClassNew":"APARTMENTS - LOW RISE","useLabel":"Apartment building","owner":"MASTER STREET HOUSING LP","coOwner":null,"marketValue":1884500,"landAssessment":740600,"improvementAssessment":1143900,"livableArea":157869,"yearBuilt":1947,"lastSale":{"price":1,"date":"2004-05-14T04:00:00Z"},"openViolations":0,"violations":[{"number":"VI-2025-009628","date":"2025-02-25","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-009629","date":"2025-02-25","code":"PM15-605.3","title":"ELECTRICAL- LIGHTING","status":"OPEN","resolutionDate":null,"resolution":null}],"violationCases":[{"number":"CF-2025-012245","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PROPERTY MAINTENANCE INVESTIGATOR","status":"CANCELLED","createdDate":"2025-02-25","completedDate":"2025-02-25","violations":[{"number":"VI-2025-009628","date":"2025-02-25","code":"PM15-305.3","title":"INTERIOR SURFACES","status":"OPEN","resolutionDate":null,"resolution":null},{"number":"VI-2025-009629","date":"2025-02-25","code":"PM15-605.3","title":"ELECTRICAL- LIGHTING","status":"OPEN","resolutionDate":null,"resolution":null}]}],"violYears":[{"y":2025,"n":2,"worst":null}],"investigations":[{"caseNumber":"CF-2025-012245","date":"2025-02-25","type":null,"status":"FAILED"}],"inspYears":[{"y":2025,"fails":1,"passes":0}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":39.977252344879034,"lng":-75.18538333418611,"geom":{"type":"Polygon","coordinates":[[[-75.184806871,39.976592067],[-75.186206548,39.976779273],[-75.185961779,39.977912115],[-75.184558576,39.977725038],[-75.184806871,39.976592067]]]},"liDistrict":"NORTH","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19121","beds":null,"baths":null,"stories":null,"lotArea":40609,"zoning":"CMX3","grade":"C","basement":null,"heater":null,"centralAir":null,"extCond":"4","intCond":"4","garage":null,"homestead":false,"mail":"230 WYOMING AVE, KINGSTON PA, 18704","mailOut":true,"appeals":[],"taxYears":[{"year":2015,"total":4040.86,"principal":3026.06,"interest":317.74,"penalty":211.82}],"taxNet":4040.86,"taxLien":false,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":0,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2017,"v":1220500,"taxable":1220500,"land":193288,"improvement":1027212,"taxableLand":193288,"taxableImprovement":1027212,"exemptLand":0,"exemptImprovement":0},{"y":2018,"v":1463200,"taxable":1463200,"land":365800,"improvement":1097400,"taxableLand":365800,"taxableImprovement":1097400,"exemptLand":0,"exemptImprovement":0},{"y":2019,"v":1463200,"taxable":1463200,"land":365800,"improvement":1097400,"taxableLand":365800,"taxableImprovement":1097400,"exemptLand":0,"exemptImprovement":0},{"y":2020,"v":1463200,"taxable":1463200,"land":365800,"improvement":1097400,"taxableLand":365800,"taxableImprovement":1097400,"exemptLand":0,"exemptImprovement":0},{"y":2021,"v":1463200,"taxable":1463200,"land":365800,"improvement":1097400,"taxableLand":365800,"taxableImprovement":1097400,"exemptLand":0,"exemptImprovement":0},{"y":2022,"v":1463200,"taxable":1463200,"land":365800,"improvement":1097400,"taxableLand":365800,"taxableImprovement":1097400,"exemptLand":0,"exemptImprovement":0},{"y":2023,"v":1463200,"taxable":1463200,"land":365800,"improvement":1097400,"taxableLand":365800,"taxableImprovement":1097400,"exemptLand":0,"exemptImprovement":0},{"y":2024,"v":1463200,"taxable":1463200,"land":365800,"improvement":1097400,"taxableLand":365800,"taxableImprovement":1097400,"exemptLand":0,"exemptImprovement":0},{"y":2025,"v":1854800,"taxable":1854800,"land":710900,"improvement":1143900,"taxableLand":710900,"taxableImprovement":1143900,"exemptLand":0,"exemptImprovement":0},{"y":2026,"v":1854800,"taxable":1854800,"land":710900,"improvement":1143900,"taxableLand":710900,"taxableImprovement":1143900,"exemptLand":0,"exemptImprovement":0},{"y":2027,"v":1884500,"taxable":1884500,"land":740600,"improvement":1143900,"taxableLand":740600,"taxableImprovement":1143900,"exemptLand":0,"exemptImprovement":0}],"taxNow":25963,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"94714","date":"2007-08-09","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2007-08-29","scope":"T.C.O. FOR 90 DAYS. PREVIOUS BUILDING PERMIT NUMBER 55006, DATED 3/5/07."},{"number":"118698","date":"2007-12-04","work":"Administrative","type":"BP_ADMINST","description":"ADMINISTRATIVE PERMIT","status":"COMPLETED","completedDate":"2008-12-12","scope":"EXTEND T.C.O.FOR PHASE I ONLY STORAGE SPACE ON EXISTING 2ND FLOOR. PREVIOUS B.P. # 55006."},{"number":"618661","date":"2015-07-17","work":"Zoning/use","type":"ZP_ZON/USE","description":"ZONING/USE PERMIT","status":"COMPLETED","completedDate":"2015-07-17","scope":"FOR THE ERECTION OF BUILDING-MOUNTED ANTENNAS ON AN EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN PLANS. FOR USE AS A WIRELESS SERVICE FACILITY ON THE SAME LOT AS EXISTING MULTI-FAMILY HOUSEHOLD LIVING (ONE HUNDRED SIXTY (160) DWELLING UNITS) ON THE SECOND-SIXTH FLOORS, BUSINESS & PROFESSIONAL OFFICES ON THE FIRST FLOOR, AND TWO HUNDRED NINETY-SIX (296) ACCESSORY OFF-STREET PARKING SPACES. SEE PERMIT #16441 FOR ADDITIONAL ALLOWED USES AS PREVIOUSLY APPROVED."},{"number":"644260","date":"2015-11-05","work":"Major alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"EXPIRED","completedDate":"2016-09-29","scope":"FOR THE INSTALLATION OF ANTENNAS AND COMMUNICATION EQUIPMENT FOR A TELECOMMUNICATION FACILITY ON THE ROOF LEVEL OF AN EXISTING BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANCIAL, ELECTRICAL AND PLUMBING WORK."},{"number":"MP-2025-000222","date":"2025-01-29","work":"New Construction","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Swap Out/Replace HVAC 3-ton ac Unit & 96% 80,000 btu furnace one-for-one: no duct work.. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000602","date":"2025-01-30","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #602 Swap Out/Replace HVAC 4-ton ac Unit & 96% 100,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000604","date":"2025-01-30","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #604 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000616","date":"2025-01-31","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For Mechanical Work to include the installation as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. 5th Floor Unit #506 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one: . NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000617","date":"2025-01-31","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For Mechanical Work to include the installation as per attached standards. Deviations from these standards require submission of construction and site plans. 5th Floor Unit #507 Replacement installation of an existing unit of same like and kind. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000606","date":"2025-02-03","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-10","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #606 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000605","date":"2025-02-03","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #605 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000603","date":"2025-02-03","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #603 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one: no duck work. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000607","date":"2025-02-04","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #607 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000608","date":"2025-02-04","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #608 Swap Out/Replace HVAC 3-ton ac Unit & 96% 80,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000609","date":"2025-02-05","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #609 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000610","date":"2025-02-05","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #610 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000611","date":"2025-02-05","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Swap Out/Replace HVAC 3-ton ac Unit & 96% 80,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000618","date":"2025-02-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 5th Floor Unit #508 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000620","date":"2025-02-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 5th Floor Unit #510 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000615","date":"2025-02-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 5th Floor Unit #505 Swap Out/Replace HVAC 3-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000613","date":"2025-02-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000614","date":"2025-02-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000612","date":"2025-02-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 6th Floor Unit #502 Swap Out/Replace HVAC 3-ton ac Unit & 96% 80,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000619","date":"2025-02-07","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 5th Floor Unit #509 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000624","date":"2025-02-11","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #403 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one: no duck work. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000622","date":"2025-02-11","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000621","date":"2025-02-11","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #401 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000626","date":"2025-02-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000625","date":"2025-02-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #404 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000627","date":"2025-02-12","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #406 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000637","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #302 Swap Out/Replace HVAC 3-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000636","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #301 Swap Out/Replace HVAC 3-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000638","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #303 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000635","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #414 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000634","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #413 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-on. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000657","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-10","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #312 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-on. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000631","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #410 Swap Out/Replace HVAC 4-ton ac Unit & 96% 100,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000628","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #407 Swap Out/Replace HVAC 4-ton ac Unit & 96% 80,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000629","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-02","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #408 Swap Out/Replace HVAC 3-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000633","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #412 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000632","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #411 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000630","date":"2025-02-18","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 4th Floor Unit #409 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000642","date":"2025-02-20","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #307 Swap Out/Replace HVAC 4-ton ac Unit & 96% 80,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000640","date":"2025-02-20","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #305 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 60,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000639","date":"2025-02-20","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #304 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000644","date":"2025-02-20","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #309 Swap Out/Replace HVAC 2.5-ton ac Unit & 96% 40,000 btu furnace one-for-one. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"},{"number":"MP-2025-000641","date":"2025-02-20","work":"Addition and/or Alterations","type":"Mechanical","description":"Mechanical / Fuel Gas Permit","status":"Expired","completedDate":"2026-03-24","scope":"EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. 3rd Floor Unit #306 Replacement installation of an existing unit of same like and kind. NO OTHER WORK PERMITTED ON THIS PERMIT. No penetrations to fire-rated assemblies. NO NEW DUCTWORK proposed on ductwork or common areas"}],"storyTag":"New construction","storyDelta":null,"timeline":[{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"permit","w":"Addition and/or Alterations"},{"y":2025,"k":"viol","w":"2 L&I violations"},{"y":2025,"k":"insp","w":"Inspection failed"}],"rented":true,"licenses":[{"number":"396052","type":"Rental","status":"Active","businessName":"MASTER STREET HOUSING PARTNERSHIP LP (PENNROSE MANAGEMENT CO AGT)","legalName":"MASTER STREET HOUSING PARTNERSHIP LP","address":"3000 MASTER ST","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":62,"issuedDate":"2007-01-05","latestIssueDate":"2026-02-14","expirationDate":"2027-02-28","inactiveDate":null}],"licenseActivity":[{"number":"396052","type":"Rental","businessName":"MASTER STREET HOUSING PARTNERSHIP LP (PENNROSE MANAGEMENT CO AGT)","legalName":"MASTER STREET HOUSING PARTNERSHIP LP","issuedDate":"2007-01-05","latestIssueDate":"2026-02-14","closureDate":null,"expirationDate":"2027-02-28","inactiveDate":null,"status":"Active","statusLabel":"Active","active":true}],"businessLicenseSourceDate":"2026-07-24","units":62,"signals":[{"kind":"transition-activity","level":"watch","title":"Recent transition activity","summary":"The property has an unusually active paper trail worth monitoring for the next permit, inspection, deed, or listing.","evidence":["10 permit events since 2023"],"caveat":"Record activity alone does not establish that a sale or redevelopment is planned."}],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"Use permit #618661: COMPLETED.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"44 permits not marked completed: 644260 (EXPIRED), MP-2025-000222 (Expired), MP-2025-000602 (Expired), MP-2025-000604 (Expired), MP-2025-000616 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"rental-license","level":"verify","title":"A rental license does not transfer with the deed","finding":"1 active Rental License record matched.","why":"If dwelling space is rented, the buyer must obtain a new annual Rental License; the seller’s license is not transferable. New applications require proof of ownership and legal occupancy, tax compliance, no open L&I violations, and lead compliance where applicable.","action":"Plan the buyer’s replacement license before settlement.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"managing-agent","level":"verify","title":"Tax mail goes outside Philadelphia; owner residence still needs verification","finding":"OPA mails the property tax record outside Philadelphia (230 WYOMING AVE, KINGSTON PA, 18704).","why":"A tax mailing destination does not establish where the owner lives. If a rental owner lives outside Philadelphia, the City requires a managing agent with a Philadelphia mailing address; the owner remains legally responsible.","action":"Verify the buyer’s residence and, if the buyer will live outside Philadelphia, identify the Philadelphia managing agent on the new license application.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"lead","level":"verify","title":"Lead compliance is a separate record","finding":"OPA records a 1947 build year; BlockReport does not receive the Health Department’s unit-level lead certificate file.","why":"Philadelphia requires covered pre-March-1978 rentals to be certified lead-safe or lead-free for a new or renewed lease and for a new or renewed Rental License. A certificate is unit-specific; a renovation does not by itself create an exemption.","action":"Request the current lead certificate or City exemption for every dwelling unit.","url":"https://www.phila.gov/documents/lead-and-healthy-homes-resources-for-landlords/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"1 failed, 0 passed, and 0 CLOSED investigation outcomes are in the fetched history; the latest dated visit was FAILED on Feb 25, 2025.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"building-certifications","level":"verify","title":"A fire-system permit exists, but no annual certification matched","finding":"43 fire/suppression-related permits matched; the fetched BIN certification feed returned no row.","why":"Installed systems in mixed-use and larger buildings generally require periodic certification, but applicability and limited-area exceptions vary. A missing BIN/address join is not proof of a compliance failure.","action":"Confirm what system was installed and whether a current annual certificate is required and filed.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/maintenance-certifications/fire-protection-certifications/"},{"id":"commercial-trash","level":"verify","title":"A separate Commercial Trash account may apply","finding":"OPA classifies the parcel as multi-family. BlockReport does not receive a current Commercial Trash account balance.","why":"Philadelphia charges qualifying small commercial, mixed-use, and multi-unit properties that use City collection; exemptions and private collection can change applicability. A use category alone does not prove a fee is due.","action":"Check the Commercial Trash account inside the date-effective Property Payoff.","url":"https://www.phila.gov/2026-06-09-pay-your-trash-fee-bill-by-june-30/"},{"id":"violations","level":"clear","title":"No open violation; closed history remains relevant","finding":"The fetched record shows 0 open and 2 historical violations across 1 case.","why":"A closed case is materially better than an open one, but it does not by itself prove that every altered use, unit, or concealed condition matches today’s approvals.","action":"Use the closed cases to target the inspection and occupancy-file review.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"}]}