Apartment building report

1030 N 48th St

13,700 sqftRSA5built 1930

Property at a glancePlace of worship

Dvir 48, LLC

2026 assessment
$9.5M OPA value, not a listing price
2027 published assessment
$11M Future roll, not the current tax bill
Neighborhood area
Wynnefield · West Park Approximate · based on ZIP 19131
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $11,411,500. It is not yet the billed-year tax basis.

$0$10M$20M$11M201320162019202220252027
Property assessmentAssessmentL&I violationAppealPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record39 events · exact dates, newest first
  1. AppealZBA Permit Denial - Special Exception
  2. InspectionL&I investigation
  3. InspectionL&I investigation
  4. L&I violationEXTERIOR AREA WEEDS
  5. CertificationFire Alarm Certification
  6. PermitAddition and/or Alterations
  7. CertificationSprinkler Certification
  8. PermitAlterations
  9. PermitAddition and/or Alterations
  10. PermitAlterations
  11. PermitAddition and/or Alterations
  12. PermitAddition and/or Alteration
  13. PermitAddition and/or Alteration
  14. PermitAddition and/or Alteration
  15. PermitAddition and/or Alteration
  16. PermitAddition and/or Alterations
  17. PermitAddition and/or Alterations
  18. PermitAddition and/or Alteration
  19. PermitAddition and/or Alteration
  20. PermitAlterations
  21. PermitAddition and/or Alterations
  22. PermitLot Line Relocation
  23. InspectionL&I investigation
  24. PermitAddition and/or Alteration
  25. CertificationSprinkler Certification
  26. InspectionL&I investigation
  27. InspectionL&I investigation
  28. L&I violationGENERAL EXTERIOR VIOLATIONS
  29. L&I violationUNSAFE STRUCTURE
  30. L&I violationCONCRETE COMPONENTS
  31. L&I violationEXTERIOR WALLS
  32. L&I violationMASONRY COMPONENTS
  33. L&I violationSTRUCTURAL DETERIORATION
  34. InspectionL&I investigation
  35. PermitAddition and/or Alteration
  36. PermitAddition and/or Alteration
  37. PermitAddition and/or Alteration
  38. CertificationFire Escape Report
  39. CertificationFacade Report

Verify the public record

$133,477/year estimated property tax

2026 taxable assessment $9,535,400 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $11,411,500. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881000487
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Place of worship, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Place of worship Hse Worship All 1 Sty Mas
Owner
Dvir 48, LLC
$ / sq ft
$833 above the $147 median for 2,826 apartments parcels citywide
Interior area
13,700 sqft
Lot size
80,004 sqft
Built
1930
Zoning
RSA5

Recorded owner

Who's behind it

Dvir 48, LLC · corporate / LLC owner

• Owns 2 properties across Philadelphia under this name, assessed at $11M combined
• Tax bills mail to 7237 State Road, Philadelphia PA, 19136

Block context

1000 block of N 48th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1000 N 48th St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 40 dated rows
  1. AppealZBA Permit Denial - Special Exception

    Appeal ZP-2025-006845 · Scheduled

    Related permit ZP-2025-006845 · SPECIAL EXCEPTION FOR AN INCREASE OF SIXTEEN (16) ROOMING UNITS FOR A TOTAL OF THIRTY-TWO (32) ROOMING UNITS IN THE SAME EXISTING DETACHED STRUCTURE WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS PERMIT.

  2. InvestigationL&I investigation

    Case CF-2025-108488 · PASSED

    The cited inspection visit was marked passed.

  3. InvestigationL&I investigation

    Case CF-2025-108488 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  4. ViolationEXTERIOR AREA WEEDS

    Case CF-2025-108488 · Violation VI-2025-077652 · Code PM15-302.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  5. CertificationFire Alarm Certification

    Certification BC-2025-018387 · Certified

    Expires 2026-05-20

  6. PermitAddition and/or Alterations

    Permit MP-2025-000514 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  7. CertificationSprinkler Certification

    Certification BC-2025-014397 · Certified

    Expires 2026-02-10

  8. PermitAlterations

    Permit PP-2023-005260 · Completed

    INSTALL 4 INCH WATER SERVICE, 11 HOT WATER HEATERS, 11 WATER CLOSETS, 11 LAVATORIES, 11 SHOWER/TUBS, 1 BACKFLOW PREVENTER, 11 KITCHEN SINKS, 6 STORM DRAINS, 11 HOT WATER HEATERS AND 11 WASHING MACHINE BOXES ACCORDING TO THE 2018 PPC AND PER PLANS.

  9. PermitAddition and/or Alterations

    Permit FP-2023-002520 · Completed

    FOR THE INSTALLATION OF AUTOMATIC WET AND DRY SPRINKLER SYSTEMS THROUGHOUT A THREE (3) STORY MULTI-FAMILY DWELLING (BUILDING "D"). SYSTEMS TO BE SERVED BY A FOUR (4) INCH FIRE SERVICE LINE CONNECTED TO AN ON-SITE SIX (6) INCH COMBINED DOMESTIC & FIRE PRIVATE INFRASTRUCTURE SERVICE LINE AND A BACKFLOW PREVENTER LOCATED IN A METER PIT. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13 BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE AP#1000934 FOR ASSOCIATED BUILDING PERMIT. [AMENDMENT 9/26/2025 FOR A CHANGE FROM NFPA 13 TO NFPA 13R SYSTEM AND A CHANGE IN BACKFLOW PREVENTER MODEL AS PER APPROVED AMENDED PLANS.]

  10. PermitAlterations

    Permit PP-2023-005258 · Completed

    INSTALL 4 INCH WATER SERVICE, 47 WATER CLOSETS, 47 LAVATORIES, 35 SHOWER/TUBS, 35 WASHING MACHINE BOXES, 35 HOT WATER HEATERS, 35 KITCHEN SINKS, 6 STORM DRAINS AND 1 BACKFLOW PREVENTER ACCORDING TO THE 2018 PPC AND PER PLANS.

  11. PermitAddition and/or Alterations

    Permit FP-2024-000227 · Completed

    FOR THE INSTALLATION OF A 4-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A BACKFLOW PREVENTION ASSEMBLY, STANDPIPES, FIRE PUMP IN ACCORDANCE WITH NFPA 13, 14, 20. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. AMENDMENT 4/30/24 TO MATCH THE UPDATED UTILITY PLAN SHOWING A 6" PRIVATE FIRE SERVICE MAIN WITH 6" BACKFLOW IN METER PIT AMENDMENT 9/15/25 TO CHANGE FROM NFPA 13 TO NFPA 13R.

  12. PermitAddition and/or Alteration

    Permit EP-2023-002890 · Completed

    Wiring apartment complex General wiring in common area, General wiring in apts, lighting, 110v interconnected smoke alarms ,em.lighting.Install new 600 Amp service. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**

  13. PermitAddition and/or Alteration

    Permit EP-2023-010443 · Completed

    Installation of Fire Alarm system as per plans -2017 NEC,2016 NFPA-72.

  14. PermitAddition and/or Alteration

    Permit EP-2023-010283 · Completed

    INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.

  15. PermitAddition and/or Alteration

    Permit EP-2023-010445 · Completed

    Installation of Fire Alarm System as per plans and 2016 NFPA 72.

  16. PermitAddition and/or Alterations

    Permit FP-2023-001861 · Completed

    INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 4" MAIN FIRE SERVICE LINE WITH 4" WILKINS 350AST BACKFLOW PREVENTION ASSEMBLY AND TWO STANDPIPES IN EXIT STAIRWAYS, STANDPIPES TO BE INTERCONNECTED PER NFPA 14. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. AMENDMENT: AMENDED DOCUMENTS AND PLANS SHOWING A 6" PRIVATE WATER SERVICE AND 6" AMES 2000SS BACKFLOW.

  17. PermitAddition and/or Alterations

    Permit MP-2023-001451 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. *Asbestos abatement required prior to commencement of work*

  18. PermitAddition and/or Alteration

    Permit EP-2023-002883 · Completed

    AMENDMENT: Reduced electrical service to 1200 amps per Engineer's drawings and as per 2017 NEC. Providing new 2000 amp service and disconnect and panel boards for each apartment. Wire throughout: lighting, receptacles, power to equipment, and smoke/CO alarms as per 2017 NEC.

  19. PermitAddition and/or Alteration

    Permit EP-2023-002884 · Completed

    Converting Existing building to apartment complex General wiring in common area and apartments, lighting, receptacles, smoke/CO alarms, HVAC, and new 800 amp service as per 2017 NEC.

  20. PermitAlterations

    Permit PP-2023-005247 · Completed

    INSTALL 4 INCH WATER SERVICE, 21 WATER CLOSETS, 21 LAVATORIES, 21 SHOWER/TUB, 16 HOT WATER HEATERS, 16 WASHING MACHINE BOXES, 16 KITCHEN SINKS, 9 STORM DRAINS AND 1 BACKFLOW PREVENTER ACCORDING TO THE 2018 PPC AND PER PLANS.

  21. PermitAddition and/or Alterations

    Permit MP-2023-001449 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  22. PermitLot Line Relocation

    Permit ZP-2023-004225 · Issued

    FOR THE RELOCATION OF LOT LINE TO CREATE TWO (2) LOTS (PARCEL B AND PARCEL C) FROM ONE (1) EXISTING DEEDED LOT WITH OPA ACCOUNT. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLAN.

  23. InvestigationL&I investigation

    Case CF-2021-102951 · PASSED

    The cited inspection visit was marked passed.

  24. PermitAddition and/or Alteration

    Permit CP-2023-000732 · Completed

    MAKE SAFE PERMIT TO RESOLVE CASE VIOLATION # CF-2021-102951 FOR FACADE RECONSTRUCTION/RESTORATION AND REPAIRS TO FOUR (4) SIDES OF THE STRUCTURE WHERE FACADE SECTIONS HAVE COLLAPSED, WITH ROOF FRAMING REPAIR AND STONE PATCHING, AS IDENTIFIED IN REPORT/PLAN, AS PER THE APPROVED ENGINEERED PLANS AND ENGINEER REPORT. IF FIELD CONDITIONS VARY CONTACT THE DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS WILL BE REQUIRED FOR ANY ADDITIONAL ALTERATIONS NOT ADDRESSED IN THE ENGINEER'S REPORT / PLANS. Abutting sidewalk must be closed with fencing a minimum of 6 ft. in height. In accordance with Code Bulletin PM-1801, a PA professional engineer is required to monitor repairs made under this permit. The engineer must submit a sealed statement to the Department confirming that the structure is in sound condition at completion.

  25. CertificationSprinkler Certification

    Certification BC-2023-005763 · Certified

    Expires 2024-03-06

  26. InvestigationL&I investigation

    Case CF-2021-102951 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  27. InvestigationL&I investigation

    Case CF-2021-102951 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  28. ViolationGENERAL EXTERIOR VIOLATIONS

    Case CF-2021-102951 · Violation VI-2021-074212 · Code PM15-304.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. ViolationUNSAFE STRUCTURE

    Case CF-2021-102951 · Violation VI-2021-074209 · Code PM15-108.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  30. ViolationCONCRETE COMPONENTS

    Case CF-2021-102951 · Violation VI-2021-074210 · Code PM15-306.1(2) · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  31. ViolationEXTERIOR WALLS

    Case CF-2021-102951 · Violation VI-2021-074211 · Code PM15-304.1(G) · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  32. ViolationMASONRY COMPONENTS

    Case CF-2021-102951 · Violation VI-2021-074213 · Code PM15-306.1(4) · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  33. ViolationSTRUCTURAL DETERIORATION

    Case CF-2021-102951 · Violation VI-2021-074214 · Code PM15-304.1(E) · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  34. InvestigationL&I investigation

    Case CF-2021-102951 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  35. PermitAddition and/or Alteration

    Permit 1000934 · Completed

    INTERIOR ALTERATIONS (LEVEL III) AND STRUCTURAL WORK AS PER APPROVED PLANS. ENTIRE BUILDING TO BE FULLY SPRINKLERED PER NFPA 13R @ MIN. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESION WORK. TYPE B DWELLING UNITS REQUIRED AT THE 1ST FLOOR LEVEL. *ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK*

  36. PermitAddition and/or Alteration

    Permit 1000937 · Completed

    FOR LEVEL III ALTERATION WITHOUT CHANGE OF OCCUPANCY CLASSIFICATION FOR A MULTI-FAMILY (16 DWELLING UNITS). BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQURIED FOR M.E.P.S WORK. Amendment to change the floor layout with associated structural changes as per approved amended plans.

  37. PermitAddition and/or Alteration

    Permit CP-2020-000484 · Completed

    FOR CHANGE IN OCCUPANCY TO R-2 AND LEVEL III ALTERATIONS TO INCLUDE ADDITION GROSS FLOOR AREA, STRUCTURAL MODIFICATIONS, PARTITIONS, STAIRS, FIXTURES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 MINIMUM. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. AMENDMENT 7/22/24 FOR LAYOUT CHANGES, WHEELCHAIR LIFT, AND OTHER MODIFICATIONS AS PER APPROVED PLANS. AMENDMENT 11/13/24 FOR REVISED FIRE RATING OF INTERIOR EXIT STAIRWAYS AND REDUCTION OF STORIES. AMENDMENT 7/8/25 TO REDUCE SPRINKLER REQUIREMENT TO NFPA 13R.

  38. CertificationFire Escape Report

    Certification BC-2023-008480 · Safe

    Expires 2023-03-26

  39. CertificationFacade Report

    Certification BC-2022-011722 · Safe with Repair

    Expires 2018-09-24

  40. PermitChange of Use

    Permit ZP-2025-006845 · Denied

    Group Living - Single-Room Residence

Where this comes from

Methodology & freshness

This report was assembled Jul 23, 2026, 7:01 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)