Commercial property report

111 S Independence Mall E

5 stories218,900 sqftCMX4built 1895

Property at a glanceOffices

Lak Bourse Owner LLC

2026 assessment
$19M OPA value, not a listing price
2027 published assessment
$19M Future roll, not the current tax bill
Neighborhood area
Old City · Society Hill Approximate · based on ZIP 19106
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $18,597,700. It is not yet the billed-year tax basis.

$0$25M$50M$19M200720112015201920232027
Property assessmentAssessmentL&I violationPermitInspection

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record174 events · exact dates, newest first
  1. PermitAlterations
  2. PermitAddition and/or Alteration
  3. PermitAddition and/or Alterations
  4. PermitAddition and/or Alteration
  5. PermitAddition and/or Alterations
  6. PermitAddition and/or Alteration
  7. PermitAlterations
  8. InspectionL&I investigation
  9. L&I violationPULL STATION SIGNS
  10. L&I violationFDC SIGNAGE REQUIRED
  11. L&I violationFIRE SUPPRESSION CERTIFICATION
  12. L&I violationILLUMINATION EMERGENCY POWER
  13. L&I violationSPILL CONTROL
  14. L&I violationFIREBLOCKING/DRAFTSTOPPING
  15. L&I violationGENERAL REQ.- CITE CODE SECTIO
  16. L&I violationGENERAL REQ.- CITE CODE SECTIO
  17. L&I violationTWO OR MORE ELEVATORS
  18. L&I violationSHELTER-IN-PLACE PLAN REQUIRED
  19. L&I violationFIRE COMMAND CENTER FEATURES
  20. L&I violationOPEN JUNCTION BOXES
  21. L&I violationNFPA 704 SIGNS
  22. L&I violationHIGH RISE LICENSE REQUIRED
  23. L&I violationHAZMAT LICENSE REQUIRED
  24. L&I violationLABELING
  25. L&I violationFIRE SAFETY/EVACUATION PLAN
  26. L&I violationCERTIFICATION
  27. L&I violationFIRE EXTINGUISHING SYSTEMS
  28. L&I violationEMERGENCY DRILL RECORD CONTENT
  29. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  30. PermitAdministrative
  31. PermitNew Construction
  32. PermitPlumbing
  33. PermitMechanical
  34. PermitMajor alteration
  35. L&I violationCONSTRUCTION DOCUMENTS
  36. PermitElectrical
  37. PermitMechanical
  38. PermitMajor alteration
  39. PermitMajor alteration
  40. PermitMechanical
  41. PermitMajor alteration
  42. PermitMechanical
  43. PermitMechanical
  44. PermitElectrical
  45. PermitElectrical
  46. PermitElectrical
  47. PermitPlumbing
  48. PermitAdministrative
  49. PermitMajor alteration
  50. PermitMajor alteration
  51. PermitMechanical
  52. PermitElectrical
  53. PermitElectrical
  54. PermitElectrical
  55. PermitElectrical
  56. PermitElectrical
  57. PermitMechanical
  58. PermitPlumbing
  59. PermitElectrical
  60. PermitElectrical
  61. PermitElectrical
  62. PermitElectrical
  63. PermitMechanical
  64. PermitMechanical
  65. PermitMechanical
  66. PermitMechanical
  67. PermitMechanical
  68. PermitMajor alteration
  69. PermitMajor alteration
  70. PermitMajor alteration
  71. PermitElectrical
  72. PermitMajor alteration
  73. PermitPlumbing
  74. PermitPlumbing
  75. PermitPlumbing
  76. PermitPlumbing
  77. PermitElectrical
  78. PermitMajor alteration
  79. PermitMajor alteration
  80. PermitSuppression
  81. PermitMechanical
  82. PermitMajor alteration
  83. PermitMajor alteration
  84. PermitElectrical
  85. PermitDemolition
  86. PermitElectrical
  87. PermitSuppression
  88. PermitElectrical
  89. PermitMajor alteration
  90. PermitMechanical
  91. PermitMajor alteration
  92. PermitElectrical
  93. PermitMajor alteration
  94. PermitElectrical
  95. PermitNew Construction
  96. PermitElectrical
  97. PermitDemolition
  98. PermitMechanical
  99. PermitElectrical
  100. PermitPlumbing
  101. PermitElectrical
  102. PermitMechanical
  103. PermitSuppression
  104. PermitMajor alteration
  105. PermitDemolition
  106. PermitPlumbing
  107. PermitMajor alteration
  108. PermitMajor alteration
  109. PermitElectrical
  110. PermitMechanical
  111. PermitMajor alteration
  112. PermitDemolition
  113. InspectionCI INSP
  114. InspectionCI INSP
  115. InspectionCI INSP
  116. InspectionCI INSP
  117. InspectionCI INSP
  118. InspectionCI INSP
  119. L&I violationEMERG LIGHTING DEFECTIVE
  120. L&I violationANNUAL CERT FIRE ALARM
  121. L&I violationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)
  122. L&I violationFIRE-DOOR/HARDWARE MAINTAIN
  123. L&I violationFIRE-MAINTAIN FIREBLOCK
  124. L&I violationFIRE-ELECT OPEN JUNCTION BOX
  125. L&I violationINT MATERIAL STORAGE EQUIP RM
  126. L&I violationINT COMBUSTIBLE WASTE ACCUMUL
  127. L&I violationVIOL C&I MESSAGE
  128. L&I violationEGRESS CLEAR OBSTRUCTION
  129. L&I violationEGRESS EXIT SIGNS VISIBILITY
  130. L&I violationEGRESS DOOR ASSEM/ED OCC APP
  131. L&I violationANNUAL CERT STANDBY/EMERG LITE
  132. L&I violationANNUAL CERT FIRE SUPP
  133. L&I violationOBTAIN PERMIT EXTEN SPRKLR SYS
  134. L&I violationEMERG LIGHTING DEFECTIVE
  135. L&I violationVIOL C&I MESSAGE
  136. L&I violationVIOL C&I MESSAGE
  137. L&I violationAFES-COMM KITCH SERVICE & CERT
  138. L&I violationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)
  139. L&I violationVIOL C&I MESSAGE
  140. L&I violationAFES-COMM KITCH SERVICE & CERT
  141. L&I violationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)
  142. L&I violationVIOL C&I MESSAGE
  143. L&I violationAFES-COMM KITCH SERVICE & CERT
  144. InspectionCI INSP
  145. InspectionCI INSP
  146. InspectionCI INSP
  147. InspectionCI INSP
  148. InspectionCI INSP
  149. InspectionCI INSP
  150. InspectionCI INSP
  151. L&I violationFIRE/EVAC PLN-AVAIL CODE OFC
  152. L&I violationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)
  153. L&I violationFIRE-MAINTAIN FIREBLOCK
  154. L&I violationUNIT STORAGE BATTERY SYS TEST
  155. L&I violationSHELTER PLN-EMPLY TRNG
  156. L&I violationSHELTER PLN-REQ¿D
  157. L&I violationFIRE/EVAC PLN-EMPLY TRNG DUTY
  158. L&I violationVIOL C&I MESSAGE
  159. L&I violationINT MATERIAL STORAGE EQUIP RM
  160. InspectionCI INSP
  161. PermitMechanical
  162. L&I violationVIOL NONE FOUND
  163. InspectionCI INSP
  164. PermitSuppression
  165. PermitUse
  166. PermitElectrical
  167. PermitMajor alteration
  168. PermitMajor alteration
  169. PermitFast form building
  170. PermitSuppression
  171. PermitDemolition
  172. PermitMajor alteration
  173. PermitMechanical
  174. PermitDemolition

Verify the public record

$260,331/year estimated property tax

2026 taxable assessment $18,597,700 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $18,597,700. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 883101510
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Offices, recorded in the City's offices category. The public record and owner trail follow.

What it is
Offices Off Bld N/Pkg N/Com Mason
Owner
Lak Bourse Owner LLC
$ / sq ft
$85 below the $142 median for 753 offices parcels citywide
Corridor
Old City city commercial corridor
Interior area
218,900 sqft
Lot size
28,659 sqft
Stories
5
Built
1895
Zoning
CMX4

Recorded owner

Who's behind it

Lak Bourse Owner LLC · corporate / LLC owner

• Owns 2 properties across Philadelphia under this name, assessed at $31M combined
• Tax bills mail to 1001 Conshohocken State Rd Suite 2-201, West Conshohocken PA, 19428 — outside Philadelphia

Block context

100 block of S Independence Mall. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 111 S Independence Mall E  ·  101 S Independence Mall E

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 174 dated rows
  1. PermitAlterations

    Permit PP-2023-002578 · Completed

    Remove and replace existing plumbing fixture with new, (1) pantry sink, connecting to existing piping.

  2. PermitAddition and/or Alteration

    Permit EP-2023-001200 · Completed

    INSTALLL LIGHTS NORMAL & ENERGENCY, SWITCHES & SENSORS. INSTALL RECEPTACLES, FURNITURE FEEDS, & POKE-THRU'S. PROVIDE CONDUITS & PULL STRINGS FOR LOW VOLTAGE WORK. INSTALL EMON DEMON METERING. PROVIDE POWER FOR THE MECHANICAL & HVAC EQUIPMENT. INSTALL NEW FIRE ALARM NOTIFICATION DEVICES & NEW POWER SUPPLY WHICH WILL BE CONNECTED TO THE EXISTING BUILDING FIRE ALARM SYSTEM ALL WORK IN ACCORDANCE WITHTHE 2017 NEC & 2016 NFPA-72. * THE SERVICE & PANELS ARE EXISTING. * NO FIRE ALARM WORK. Amendment: FIRE ALARM - INSTALL FIRE ALARM RACEWAY AND CONDUCTORS TO MEET BUILDING SPEC. INSTALL HORN AND STROBE DEVICES. MODIFY EXISTING FIRE ALARM TO ACCOMADATE NEW TENANT IN SPACE.

  3. PermitAddition and/or Alterations

    Permit MP-2023-000393 · Completed

    FOR ALTERATIONS TO HVAC SYSTEM FOR NEW OFFICE LAYOUT AS PER PLANS.

  4. PermitAddition and/or Alteration

    Permit EP-2023-001412 · Completed

    Provide and install 57 Cat6 plenum cables at 100' average. All cabling will be installed per 2017 NEC. No rescue systems work.

  5. PermitAddition and/or Alterations

    Permit FP-2023-000292 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating (9) sprinkler heads for renovations

  6. PermitAddition and/or Alteration

    Permit CP-2022-005164 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 9TH FLOOR LEVEL FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING TO BE FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**AMENDED AS OF 2/14/2023 TO DOCUMENT CHANGES AS PER PLANS**

  7. PermitAlterations

    Permit PP-2022-017614 · Completed

    Remove and replace existing fixtures with new, (1) lavatory, (1) water closet, (1) electric water heater and (1) drinking fountain, connecting to existing piping.

  8. InvestigationL&I investigation

    Case 726980 · PASSED

    The cited inspection visit was marked passed.

  9. ViolationPULL STATION SIGNS

    Case 726980 · Violation 211995975 · Code FC-13-907.51 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  10. ViolationFDC SIGNAGE REQUIRED

    Case 726980 · Violation 211995977 · Code FC-13-912.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  11. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 726980 · Violation 211995978 · Code FC-13-915.1A · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  12. ViolationILLUMINATION EMERGENCY POWER

    Case 726980 · Violation 211995979 · Code FC-13-1006.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  13. ViolationSPILL CONTROL

    Case 726980 · Violation 211995980 · Code FC-13-2704.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  14. ViolationFIREBLOCKING/DRAFTSTOPPING

    Case 726980 · Violation 211995981 · Code FC-13-703.11 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  15. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 726980 · Violation 211995982 · Code FC-13-1008 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  16. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 726980 · Violation 211995983 · Code FC-13-1007 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  17. ViolationTWO OR MORE ELEVATORS

    Case 726980 · Violation 211995984 · Code FC-13-604183 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  18. ViolationSHELTER-IN-PLACE PLAN REQUIRED

    Case 726980 · Violation 211995985 · Code FC-13-404.33 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  19. ViolationFIRE COMMAND CENTER FEATURES

    Case 726980 · Violation 211995986 · Code FC-13-508.15 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  20. ViolationOPEN JUNCTION BOXES

    Case 726980 · Violation 211995987 · Code FC-13-605.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  21. ViolationNFPA 704 SIGNS

    Case 726980 · Violation 211995988 · Code FC-13-2703.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. ViolationHIGH RISE LICENSE REQUIRED

    Case 726980 · Violation 211995989 · Code FC-13-408.12 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  23. ViolationHAZMAT LICENSE REQUIRED

    Case 726980 · Violation 211995990 · Code FC-13-2701.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  24. ViolationLABELING

    Case 726980 · Violation 211995991 · Code FC-13-605.31 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  25. ViolationFIRE SAFETY/EVACUATION PLAN

    Case 726980 · Violation 211995992 · Code FC-13-404.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  26. ViolationCERTIFICATION

    Case 726980 · Violation 211995993 · Code FC-13-915 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  27. ViolationFIRE EXTINGUISHING SYSTEMS

    Case 726980 · Violation 211995976 · Code FC-13-105.71 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. ViolationEMERGENCY DRILL RECORD CONTENT

    Case 726980 · Violation 211995974 · Code FC-13-405 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 726980 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  30. PermitAdministrative

    Permit 1023354 · COMPLETED

    ADMINISTRATIVE CERT. OF OCCUPANCY

  31. PermitNew Construction

    Permit 1012118 · Expired

    REPLACE EXISTING FA PULL STATIONS ON FLOORS 3,4,9 & 10 AND INSTALL FA DEVICES IN 6TH & 7TH FLOOR SUITES PER NFPA 72

  32. PermitPlumbing

    Permit 992406 · COMPLETED

    FURNISH AND INSTALL SANITARY, SANITARY VENT AND DOMESTIC WATER PIPE FOR TWO NEW SINKS. FURNISH AND INSTALL TWO NEW SINKS AS PER 2004 PPC

  33. PermitMechanical

    Permit 990151 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT ON THE 8TH FLOOR OF AN EXISTING BUILDING TO INCLUDE INSTALLATION OF VAV DAMPERS, DUCTWORK AND DIFFUSERS AS PER APPROVED PLANS.

  34. PermitMajor alteration

    Permit 986269 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SUITE 8400 OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  35. ViolationCONSTRUCTION DOCUMENTS

    Case 956897 · Violation 5005520 · Code A-302.5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  36. PermitElectrical

    Permit 962586 · COMPLETED

    RELOCATE 7 EXISTING FIXTURES AND 4 NEW SINGLE POLE SWITCHES IN EXISTING LOCATIONS. INSTALL 6 NEW WALL MOUNTED FURNITURE FEEDS. INSTALL 2 NEW CIRCUITS AND 12 DUPLEX RECEPTACLES USING EXISTING 208/120V, 3PH, 4W, 250AMP PANEL 9A-1 AS DRAWINGS AS PER 2008 NEC. (CC DIST)

  37. PermitMechanical

    Permit 965242 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  38. PermitMajor alteration

    Permit 953464 · COMPLETED

    FOR LEVEL II ALTERATIONS ON 3RD FLOOR OF AN EXISTING OFFICE BUILDING AS PER PLANS. ** SEPARATE PERMITS REQUIRED FOR M.E.P.S.** *IEBC 09*

  39. PermitMajor alteration

    Permit 956897 · COMPLETED

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. INTERIOR ALTERATIONS (PRESCRIPTIVE METHOD) AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  40. PermitMechanical

    Permit 931694 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM INCLUDING DUCTWORK FOR 5TH FLOOR OFFICE SPACE IN AN EXISTING BUILDING AS PER APPROVED PLANS.

  41. PermitMajor alteration

    Permit 931691 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING 3RD, 4TH, 6TH, 8TH, 9TH AND 10TH FLOORS. ALTERATIONS TO INCLUDE DEMOLITION AND ERECTION OF NON-STRUCTURAL PARTITIONS, ACCESSIBILITY UPGRADES AND FINISHED. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MECHANICAL, ELECTRICAL, PLUMBING OR FIRE SUPPRESSION WORK**

  42. PermitMechanical

    Permit 914556 · COMPLETED

    FOR ALTERATIONS TO THE EXISTING MECHANICAL SYSTEMS WITHIN THE BATHROOMS ON THE 3RD/4TH FLRS, AND THROUGHOUT THE ENTIRE 6TH-8TH FLRS, WITHIN THE BOURSE BUILDING, AS PER PLANS AND PHC APPROVAL; NO OTHER WORK ON THIS PERMIT.

  43. PermitMechanical

    Permit 908093 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM TO INCLUDE NEW DUCTWORK, VAV BOX AND EXHAUST FAN WITH (6) REGISTERS/DIFFUSERS TO ACCOMMODATE NEW OFFICE LAYOUT ON THE EIGHTH FLOOR AS PER APPROVED PLANS.

  44. PermitElectrical

    Permit 902150 · COMPLETED

    INSTALL 3 SPOT LIGHTS, 4 PENDANT LIGHTS, 6 TASK LIGHTS USING EXISTING LIGHTING BRANCH CIRCUITS AND SWITCHING AS PER 2008 NEC (CC DISTRICT)

  45. PermitElectrical

    Permit 912398 · COMPLETED

    PROVIDE AND INSTALL 12 CAT5E PLENUM CABLE @ 100'AVERAGE. ALL CABLING WILL BE INSTALLED IN J-HOOKS AND ALL PENETRATIONS WILL BE FIRE STOPPED PER 2008 NEC (OFFICE)

  46. PermitElectrical

    Permit 907398 · COMPLETED

    INSTALL 1 NEW 2X2 FIXTURE 1 NEW LIGHT SWITCH INSTALL 4 NEW RECEPTACLES 3 NEW FURNITURE FEED USING EXISTING 100AMP 208/120V 3PH PANEL AS PER 2008 NEC (CC DISTRICT)

  47. PermitPlumbing

    Permit 882913 · COMPLETED

    ALTERATIONS: INTERIOR PLUMBING; NEW CARRIERS; 25 WATER CLOSETS, 3 URINALS, 22 LAVATORY SINKS, 2 ELECTRIC WATER COOLERS - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  48. PermitAdministrative

    Permit 905726 · COMPLETED

    CERTIFICATE OF OCCUPANCY

  49. PermitMajor alteration

    Permit 901706 · COMPLETED

    FOR INTERIOR LEVEL 2 ALTERATIONS TO ENLARGE EXISTING SPACE WITH STANDARD FINISHES. NO STRUCTURAL WORK OR WORK TO THE FACADE OF THE BUILDING. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  50. PermitMajor alteration

    Permit 874159 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING STALL FOR USE AS A TAKEOUT RESTAURANT. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  51. PermitMechanical

    Permit 878550 · COMPLETED

    FOR MECHANICAL WORK INCLUDING FUEL GAS PIPING AS PER PLANS. SEPARATE PERMIT REQUIRED FOR ALL FIRE SUPPRESSION AND ELECTRICAL WORK.

  52. PermitElectrical

    Permit 840460 · COMPLETED

    PROVIDE & INSTALL 80-RECEPTACLES, 15-EQUIPMENT POWER, 160-LIGHT FIXTURES, LIGHTING CONTROLS, POWER PANELS, TRANSFORMER ASSOCIATED FEEDERS AND BRANCH CIRCUIT CABLING AS PER NEC 2008 CC DISTRICT

  53. PermitElectrical

    Permit 860658 · COMPLETED

    PROVIDE INSTALLATION OF 14-RECEPTACLES, 9-EQUIPMENT POWER, 42-LIGHT FIXTURES & LIGHTING CONTROLS & ASSOCIATED BRANCH CKTS AS PER NEC 2008 CC DISTRICT

  54. PermitElectrical

    Permit 859838 · COMPLETED

    PROVIDE INSTALLATION OF 18-SPEAKER/STROBE, 1-STROBE, 4-PULL STATION, 1-POWER SUPPLY AND ASSOCIATED CABLING AS PER NFPA 72

  55. PermitElectrical

    Permit 859839 · COMPLETED

    PROVIDE INSTALLATION OF 10-SPEAKER/STROBE, 8-STROBE, 2-PULL STATION, 1-POWER SUPPLY AND ASSOCIATED CABLING AS PER NFPA 72

  56. PermitElectrical

    Permit 859836 · COMPLETED

    PROVIDE INSTALLATION OF 15-SPEAKER/STROBE, 3-STROBE, 2-PULL STATION, 1-POWER SUPPLY AND ASSOCIATED CABLING AS PER NFPA 72

  57. PermitMechanical

    Permit 860747 · COMPLETED

    FOR THE INSTALLATION OF DUCTWORK AND REGISTERS/DIFFUSERS.

  58. PermitPlumbing

    Permit 843277 · COMPLETED

    FURNISH & INSTALL 3-WATER CLOSETS, 1-URINAL, 4-LAVS, 3-SHOWERS, & 1-MOP RECEPTOR IN MEN & WOMEN LOCKER ROOM THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  59. PermitElectrical

    Permit 851369 · COMPLETED

    PROVIDE INSTALLATION OF 12-RECEPTACLES, 4-EQUIPMENT POWER, 25-LIGHT FIXTURES, LIGHTING CONTROLS AND ASSOCIATED BRANCH CIRCUIT AS PER NEC 2008 CC DISTRICT

  60. PermitElectrical

    Permit 845748 · COMPLETED

    PROVIDE INSTALLATION OF 16-RECEPTACLES, 2-EQUIPMENT POWER, 43-LIGHT FIXTURES, POWER PANLES, TRANSFORMER & FEDDERS, LIGHTING CONTROLS &ASSOCIATED BRANCH CIRCUITS AS PER NEC 2008 CC DISTRICT**NO FIRE ALARM**

  61. PermitElectrical

    Permit 823235 · COMPLETED

    INSTALL NEW 250KW GENERATOR (DIESEL) ON UPPER LEVEL B2 AND INSTALL NEW PANEL & LIGHTS ON UPPER LEVEL B2 AS PER NEC 2008 CC DISTRICT AND FIRE ALARM AS PER NFPA 72

  62. PermitElectrical

    Permit 844545 · COMPLETED

    PROVIDE INSTALLATION OF 24-RECEPTACLES, 6-EQUIPMENT POWER, 64-LIGHTING CONTROLS AND ASSOCIATED BRANCH CIRCUIT AS PER NEC 2008 CC DISTRICT

  63. PermitMechanical

    Permit 842429 · COMPLETED

    FOR THE INSTALLATION OF DUCTWORK AND SIX (6) REGISTERS/DIFFUSERS ON THE 8TH AND 9TH FLRS WITHIN THE ELEVATOR LOBBY AND CORRIDORS OF AN EXISTING HIGH-RISE HISTORIC OFFICE BUILDING, AS PER PLANS AND PHC APPROVAL DATED 12/29/17; NO OTHER WORK ON THIS PERMIT; SEE AP#830830 FOR FIT-OUT PERMIT.

  64. PermitMechanical

    Permit 842425 · COMPLETED

    FOR THE INSTALLATION OF AN HVAC SYSTEM W/DUCTWORK AND ELEVEN (11) REGISTERS/DIFFUSERS WITHIN AN OFFICE TENANT (MEYER & FORMCRAFT) ON THE 8TH FLR OF AN EXISTING HIGH-RISE HISTORIC OFFICE BUILDING, AS PER PLANS AND PHC APPROVAL DATED 12/29/17; NO OTHER WORK ON THIS PERMIT; SEE AP#830831 FOR FIT-OUT WORK.

  65. PermitMechanical

    Permit 842427 · COMPLETED

    FOR MECHANICAL ALTERTATIONS TO EXISTING SPACE, TO INCLUDE NEW REGISTERS/DIFFUERS WITH ASSOCIATED DUCTWORK, AS PER APPROVED PLANS.

  66. PermitMechanical

    Permit 842426 · COMPLETED

    FOR MECHANICAL ALTERTATIONS TO EXISTING SPACE, TO INCLUDE NEW REGISTERS/DIFFUERS WITH ASSOCIATED DUCTWORK, AS PER APPROVED PLANS.

  67. PermitMechanical

    Permit 842428 · COMPLETED

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK FOR A BUSINESS OCCUPANCY ON THE 10TH FLOOR OF AN EXISTING BUILDING. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  68. PermitMajor alteration

    Permit 840064 · EXPIRED

    FOR LEVEL II ALTERATIONS TO INCLUDE INTERIOR DEMOLITION OF THE FOLLOWING TENANT SPACES: 840 AND 875. SEPARATE PERMIT TO BE OBTAINED FOR CERTIFICATE OF OCCUPANCY AND INTERIOR FITOUT OF EACH TENANT SPACE. BUILDING TO BE FULL SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  69. PermitMajor alteration

    Permit 840068 · COMPLETED

    FOR INTERIOR ALTERATIONS TO EXISTING SPACES TO DEMOLISH AND CONSTRUCT INTERIOR PARTITIONS AND INTERIOR FINISHES, AS PER APPROVED PLANS.

  70. PermitMajor alteration

    Permit 830831 · COMPLETED

    INTERIOR RENOVATIONS TO INCLUDE NEW PARTITIONS AND FINISHES AS PER PLANS.

  71. PermitElectrical

    Permit 840462 · COMPLETED

    PROVIDE & INSTALL 8-RECEPTACLES, 149-LIGHT FIXTURES, LIGHTING CONTROLS AND ASSOCIATED BRANCH CIRCUIT AS PER NEC 2008 CC DISTRICT

  72. PermitMajor alteration

    Permit 830827 · COMPLETED

    INTERIOR ALTERATIONS TO INCLUDE NEW PARTITIONS WITHIN EXISTING OFFICE SPACE, AS SHOWN ON PLANS

  73. PermitPlumbing

    Permit 843274 · COMPLETED

    FURNISH AND INSTALL 1 SINK AND FAUCET AT NEW PANTRY.CONNECT TO THE EXISTING SANITARY WASTE AND VENT AND COLD WATER PIPING THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  74. PermitPlumbing

    Permit 843273 · COMPLETED

    FURNISH AND INSTALL 1 SINK AND FAUCET AT NEW PANTRY.CONNECT TO THE EXISTING SANITARY WASTE AND VENT AND COLD WATER PIPING THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  75. PermitPlumbing

    Permit 843276 · COMPLETED

    REMOVE AND REPLACE EXISTING PLUMBING FIXTURE & TRIM.CONSISTING OF 14 WC,2 URINALS,11 LAVS,2 ELECTRIC WATER COOLERS. CONNECT TO THE EXISTING PLUMBING ROUGH IN WITH NO MODIFICATIONS (OFFICE THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  76. PermitPlumbing

    Permit 843275 · COMPLETED

    FURNISH AND INSTALL 1 SINK AND FAUCET AT NEW PANTRY.CONNECT TO THE EXISTING SANITARY WASTE AND VENT AND COLD WATER PIPING THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  77. PermitElectrical

    Permit 838321 · COMPLETED

    INSTALL FIRE ALARM PER NFPA 72 (OFFICE SPACE)

  78. PermitMajor alteration

    Permit 830825 · COMPLETED

    LEVEL II ALTERATIONS TO ACCOMMODATE NEW OFFICE LAYOUT ON THE 9TH FLOOR OF AN EXISTING OFFICE BUILDING AS PER PLANS, WORK TO INCLUDE NON-BEARING PARTITIONS, MILWORK AND FINISHES, NO CHANGE IN USE-OCCUPANCY CLASSIFICATION, SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS,

  79. PermitMajor alteration

    Permit 830822 · COMPLETED

    FOR LEVEL II ALTERATIONS TO SIX (6) RESTROOMS ACCESSORY TO EXISTING BUISNESS USE ON THE 8THAND 9TH FLOOR LEVEL OF AN EXISTING BUILDING, ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  80. PermitSuppression

    Permit 839402 · COMPLETED

    WE WILL BE RELOCATIONG (203) SPRINKLERS IN THE 8TH,9TH, AND 10TH FLOOR FITNESS CENTER - EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  81. PermitMechanical

    Permit 836382 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.RELOCATE (12) DIFFUSERS, TO COMPLYWITH EZ PERMIT STANDARDS FOR DUCTWORK.

  82. PermitMajor alteration

    Permit 830807 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY (NO CHANGE OF OCCUPANCY CLASSIFICATION, GROUP B < 50) FOR RENOVATIONS TO FIT-OUT AN EXISTING OFFICE SPACE AND TO CREATE AN ACCESSORY FITNESS CENTER ON THE 10TH FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  83. PermitMajor alteration

    Permit 830830 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING 8TH AND 9TH FLOOR CORRIDORS AND ELEVATOR LOBBIES WITHIN AN EXISTING OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  84. PermitElectrical

    Permit 826313 · COMPLETED

    RELOCATE 5-EXISTING HORN/STROBES WITH EXISTING WIRING AS PER NFPA 72

  85. PermitDemolition

    Permit 817990 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  86. PermitElectrical

    Permit 801983 · COMPLETED

    LEVEL 2 INTERIOR RENOVATION TO SUITE 12 ON THE 19TH FLOOR OF AN EXISTING OFFICE BUILDING INCLUDING POWER AND LIGHTING PER NEC (OFFICE SPACE)FIRE ALARM USING EXISTING PANELS TO FEED DEVICES EXTENDING FIRE ALARM FROM EXISTING FIRE PANEL PER NFPA 72

  87. PermitSuppression

    Permit 808884 · COMPLETED

    INSTALLATION OF NEW SPRINKLER LINES AND THIRTY-FIVE (35) HEADS OFF EXISTING MAINS TO SERVE ALTERED NINTH FLOOR OFFICE LAYOUT WITHIN AN EXISTING BUILDING IN ACCORDANCE WITH THE NFPA 13 STANDARD AND AS PER APPROVED PLANS.

  88. PermitElectrical

    Permit 807480 · COMPLETED

    INSTALL OUTLETS, SWITCHES AND LIGHTS AS PER NEC 2008 CC DISTRICT

  89. PermitMajor alteration

    Permit 803082 · COMPLETED

    FOR INTERIOR ALTERATIONS TO EXISTING SPACE, TO INCLUDE NEW INTERIOR PARTITIONS AND INTERIOR FINISHES, AS PER APPROVED PLANS.

  90. PermitMechanical

    Permit 801450 · COMPLETED

    HVAC, INCLUDING RELATED DUCTWORK TO THE 9TH FLOOR (UNIT B) AS PER PLANS. NO EXTERIOR WORK.

  91. PermitMajor alteration

    Permit 772857 · COMPLETED

    LEVEL 2 INTERIOR RENOVATION TO SUITE 12 ON THE 9TH FLOOR OF AN EXISTING OFFICE BUILDING AS PER PLANS. SEPARATE PERMITS REQUIRED FOR M, E, P.

  92. PermitElectrical

    Permit 786315 · COMPLETED

    INSTALL FIRE ALARM AS PER NFPA 72 CC DISTRICT

  93. PermitMajor alteration

    Permit 787124 · COMPLETED

    CONSTRUCTION OF CLOSET TO HOUSE ELECTRICAL EQUIPMENT. SEPARATE PERMIT REQ'D FOR ANY ELECTRICAL & FIRE SUPPRESSION WORK.

  94. PermitElectrical

    Permit 772868 · COMPLETED

    INSTALL NE LIGHTS OUTLETS SWITCHES AS PER PLANS PER 2008 NEC.

  95. PermitNew Construction

    Permit 772880 · Expired

    REWORK EXISTING ELECTRIC IN BATHROOMS INSTALL NEW LIGHT FIXTURES MOTION SWITCHING GFI OUTLETS AS PER 2008 NEC.

  96. PermitElectrical

    Permit 769611 · COMPLETED

    INSTALL NEW LIGHT FIXTURES, NEW MOTION SWITCHING AND NEW EXIT SIGNS PER 2008 NEC (OFFICE SPACE)CC DISTRICT

  97. PermitDemolition

    Permit 773240 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  98. PermitMechanical

    Permit 770754 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  99. PermitElectrical

    Permit 769609 · COMPLETED

    REWORK EXISTING ELECTRICAL IN BATHROOM, INSTALL NEW LIGHT FIXTURES. NEW MOTION SWITCHING, NEW GFI OUTLET PER 2008 NEC (OFFICE SPACE)

  100. PermitPlumbing

    Permit 765648 · COMPLETED

    DISCONNECT 9- WATER CLOSETS, 3-URINALS, 7- LAVATORIES. INSTALL 8- WATER CLOSETS, 3- URINALS, 7- LAVATORIES IN SAME LOCATION.

  101. PermitElectrical

    Permit 759241 · COMPLETED

    INSTALL 10 FIRE ALARM CONTROL MODULES INTO NEW ELEVATOR CABINETS, 60 SMOKE DETECTORS, AND 22 FIRE ALARM TERMINATION BOXES AS PER NFPA 72. INSTALL 30-1X4 LIGHTS, 6-20 AMP DISCONNECT SWITCHES FOR CAB LIGHTS 6-ELEVATOR RE-CONNECTIONS, 6 NEW 100 AMP SHUNT TRIP BREAKERS, 12 RECEPTACLES, AND 8 SWITCHES AS 2008 NEC. (CC DISTRICT)

  102. PermitMechanical

    Permit 767400 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  103. PermitSuppression

    Permit 754665 · COMPLETED

    ALTERATIONS TO EXISTING NFPA 13 SPRINKLER SYSTEM FOR RENOVATIONS TO 9TH FLOOR FOR AMENITY/LOUNGE TO INCLUDE REMOVAL AND REPLACEMENT OF EXISTING BRANCHLINES AND MAIN AS PER APPROVED PLANS. NO CHANGES TO EXISTING FEED OR FLOOR CONTROL VALVE PIPING.

  104. PermitMajor alteration

    Permit 746343 · EXPIRED

    FOR LEVEL II ALTERATIONS TO THE 8TH, 9TH AND 10TH FLOOR TO AN EXISTING BUILDING FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHING THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  105. PermitDemolition

    Permit 761660 · COMPLETED

    FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  106. PermitPlumbing

    Permit 760521 · COMPLETED

    INSTALLATION OF SOIL, VENT AND DOMESTIC WATER PIPE TO NEW PANTRY SINK LOCATION

  107. PermitMajor alteration

    Permit 740221 · COMPLETED

    INTERIOR ALTERATIONS TO EXISTING OFFICE SPACE. ACCESSIBLE ROUTE, REST ROOMS, AND REQUIRED FEATURES SHALL BE PROVIDED AS PART OF RENOVATION PERMIT AP# 753877.

  108. PermitMajor alteration

    Permit 753877 · COMPLETED

    RENOVATION OF EXISTNG RESTROOMS AS PER PLANS. **SEPARATE PLUMBING PERMIT IS REQUIRED**

  109. PermitElectrical

    Permit 741887 · COMPLETED

    INSTALL 1 NEW 150AMP 208VOLT PANEL,72 NEW LIGHT FIXTURES AND 37 NEW RECEPTACLES PER 2008 NEC (OFFICE SPACE)CC DISTRICT

  110. PermitMechanical

    Permit 740643 · COMPLETED

    PARTIAL DEMOLITION AND RELOCATION OF EXISTING HVAC EQUIPMENT AND INSTALLATION OF NEW DUCTWORK, VAV BOX, EXHAUST FAN, GRILLES, REGISTERS AND DIFFUSERS AS PER PLANS.

  111. PermitMajor alteration

    Permit 721993 · COMPLETED

    FOR LEVEL II ALTERATIONS TO A TENANT SPACE FOR USE AS A LOUNGE AND OFFICE AREA ACCESSORY TO EXISTING BUISNESS USE ON THE 9TH FLOOR LEVEL OF AN EXISTING BUILDING, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  112. PermitDemolition

    Permit 666456 · COMPLETED

    DEMOLITION OF NON HISTORIC INTERIOR NON BEARING DRYWALL ON METAL STUD PARTITIONS FLOORS FINISHED AND ACT CEEILING IN VACANT TENANT OFFICE SPACES. THE DEMO WILL TAKE PLACE ON FLOORS FIFTH, SIXTH, SEVENTH,EIGHTH, NINTH AND TENTH FLOORS

  113. InvestigationCI INSP

    Case 470155 · PASSED

    The cited inspection visit was marked passed.

  114. InvestigationCI INSP

    Case 470155 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  115. InvestigationCI INSP

    Case 470163 · PASSED

    The cited inspection visit was marked passed.

  116. InvestigationCI INSP

    Case 470160 · PASSED

    The cited inspection visit was marked passed.

  117. InvestigationCI INSP

    Case 470159 · PASSED

    The cited inspection visit was marked passed.

  118. InvestigationCI INSP

    Case 470158 · PASSED

    The cited inspection visit was marked passed.

  119. ViolationEMERG LIGHTING DEFECTIVE

    Case 470155 · Violation 3515746 · Code FC-1006.3/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  120. ViolationANNUAL CERT FIRE ALARM

    Case 470155 · Violation 3515762 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  121. ViolationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)

    Case 470155 · Violation 3515761 · Code FC-906.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  122. ViolationFIRE-DOOR/HARDWARE MAINTAIN

    Case 470155 · Violation 3515758 · Code FC-703.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  123. ViolationFIRE-MAINTAIN FIREBLOCK

    Case 470155 · Violation 3515755 · Code FC-703.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  124. ViolationFIRE-ELECT OPEN JUNCTION BOX

    Case 470155 · Violation 3515752 · Code FC-605.6/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  125. ViolationINT MATERIAL STORAGE EQUIP RM

    Case 470155 · Violation 3515751 · Code FC-315.2/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  126. ViolationINT COMBUSTIBLE WASTE ACCUMUL

    Case 470155 · Violation 3515750 · Code FC-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  127. ViolationVIOL C&I MESSAGE

    Case 470155 · Violation 3515745 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  128. ViolationEGRESS CLEAR OBSTRUCTION

    Case 470155 · Violation 3515749 · Code FC-1027.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  129. ViolationEGRESS EXIT SIGNS VISIBILITY

    Case 470155 · Violation 3515748 · Code FC-1011.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  130. ViolationEGRESS DOOR ASSEM/ED OCC APP

    Case 470155 · Violation 3515747 · Code FC-1008.1/7 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  131. ViolationANNUAL CERT STANDBY/EMERG LITE

    Case 470155 · Violation 3515764 · Code FC-915.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  132. ViolationANNUAL CERT FIRE SUPP

    Case 470155 · Violation 3515763 · Code FC-915.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  133. ViolationOBTAIN PERMIT EXTEN SPRKLR SYS

    Case 470158 · Violation 3485090 · Code FC-901.4/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  134. ViolationEMERG LIGHTING DEFECTIVE

    Case 470158 · Violation 3485089 · Code FC-1006.3/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  135. ViolationVIOL C&I MESSAGE

    Case 470158 · Violation 3485088 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  136. ViolationVIOL C&I MESSAGE

    Case 470159 · Violation 3485099 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  137. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 470159 · Violation 3485100 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  138. ViolationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)

    Case 470159 · Violation 3485101 · Code FC-906.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  139. ViolationVIOL C&I MESSAGE

    Case 470160 · Violation 3485114 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  140. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 470160 · Violation 3485115 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  141. ViolationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)

    Case 470160 · Violation 3485116 · Code FC-906.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  142. ViolationVIOL C&I MESSAGE

    Case 470163 · Violation 3485127 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  143. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 470163 · Violation 3485128 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  144. InvestigationCI INSP

    Case 470155 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  145. InvestigationCI INSP

    Case 470158 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  146. InvestigationCI INSP

    Case 470159 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  147. InvestigationCI INSP

    Case 470160 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  148. InvestigationCI INSP

    Case 470163 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  149. InvestigationCI INSP

    Case 410283 · PASSED

    The cited inspection visit was marked passed.

  150. InvestigationCI INSP

    Case 410283 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  151. ViolationFIRE/EVAC PLN-AVAIL CODE OFC

    Case 410283 · Violation 3049190 · Code FC-404.5/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  152. ViolationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)

    Case 410283 · Violation 3049196 · Code FC-906.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  153. ViolationFIRE-MAINTAIN FIREBLOCK

    Case 410283 · Violation 3049195 · Code FC-703.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  154. ViolationUNIT STORAGE BATTERY SYS TEST

    Case 410283 · Violation 3049194 · Code FC-604.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  155. ViolationSHELTER PLN-EMPLY TRNG

    Case 410283 · Violation 3049193 · Code FC-409.4/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  156. ViolationSHELTER PLN-REQ¿D

    Case 410283 · Violation 3049192 · Code FC-409.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  157. ViolationFIRE/EVAC PLN-EMPLY TRNG DUTY

    Case 410283 · Violation 3049191 · Code FC-406.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  158. ViolationVIOL C&I MESSAGE

    Case 410283 · Violation 3049188 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  159. ViolationINT MATERIAL STORAGE EQUIP RM

    Case 410283 · Violation 3049189 · Code FC-315.2/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  160. InvestigationCI INSP

    Case 410283 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  161. PermitMechanical

    Permit 471080 · COMPLETED

    PARTIAL DEMOLITION AND RELOCATION OF EXISTING HVAC EQUIPMENT AND INSTALLATION OF NEW DUCTWORK, VAV BOX, EXHAUST FAN, GRILLES, REGISTERS AND DIFFUSERS IN AN EXISTING OFFICE SPACE PER PLANS APPROVED BY THE PHILADELPHIA HISTORICAL COMMISSION. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL WORK.

  162. ViolationVIOL NONE FOUND

    Case 357509 · Violation 2625232 · Code A-000.0/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  163. InvestigationCI INSP

    Case 357509 · PASSED

    The cited inspection visit was marked passed.

  164. PermitSuppression

    Permit 417034 · COMPLETED

    RELOCATE 9 SPRINKLER HEADS.

  165. PermitUse

    Permit 312039 · COMPLETED

    AD SALE OF TOUR TICKETS AND OTHER EVENTS AND KEEP OTHER APPROVED USES

  166. PermitElectrical

    Permit 156339 · COMPLETED

    INSTALLATION OF 120 CAT 6 CABLES, LONGEST RUN 200'.

  167. PermitMajor alteration

    Permit 157854 · EXPIRED

    PARTIAL DEMO OF INTERIOR WALLS, BUILDING NEW PARTIITONS AND FINISHES

  168. PermitMajor alteration

    Permit 152798 · COMPLETED

    FOR INTERIOR ALTERATIONS FOR A PARTIAL TENANT FIT OUT FOR THE 3RD AND 4TH FLOORS FOR ADULT EDUCATION. ALL WORK SHALL CONFORM TO THE APPROVED PLANS.

  169. PermitFast form building

    Permit 147570 · COMPLETED

  170. PermitSuppression

    Permit 133903 · COMPLETED

    RELOCATE 1 AUTO SPRINKLER ON 7TH FLOOR

  171. PermitDemolition

    Permit 131479 · COMPLETED

    INTERIOR DEMOLITION OF NON BEARING PARTITIONS, CARPET, TILES , ETC

  172. PermitMajor alteration

    Permit 128662 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLANS

  173. PermitMechanical

    Permit 70726 · COMPLETED

    RELOCATE 6 REGISTERS/DIFFUSERS

  174. PermitDemolition

    Permit 67838 · COMPLETED

    INTERIOR NON-BEARING DEMOLITION (7TH FLOOR, WEST SIDE)

Where this comes from

Methodology & freshness

This report was assembled Jul 28, 2026, 10:34 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)