Property report
112 S 19th St
24 stories260,172 sqftCMX4built 2019
19r Chestnut Partners LP
Assessment and City record timeline
The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.
Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $63,711,200. It is not yet the billed-year tax basis.
- OPA assessment · 2016$495K assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2019$31M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2020$62M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2021$62M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2022$62M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2023$62M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2024$62M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2025$62M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2026$62M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2027$64M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- Permit · 2015-05-12PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-05-26Zoning/useThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-05-26DemolitionThis permit category usually covers partial or complete removal work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-12-11UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2016-09-15ZoningThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-02-21UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-10-31DemolitionThis permit category usually covers partial or complete removal work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-11-20AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-12-18New constructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-03-28PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-07-12PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-07-24SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-09-10ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-12-06MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-01-09PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-01-18UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-01-18Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2019-02-13SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-02-15MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-03-05SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-03-05New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Appeal · 2019-03-05Building standards appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Permit · 2019-03-12ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-03-18Amend for conversionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-04-17PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-05-28AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-06-14AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-07-24AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-08-06New constructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-08-06MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-08-07SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-08-15AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-09-10AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-09-10AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-09-11ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-09-18PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-12-26UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-02-21New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-03New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-09Rough-InThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-10New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-06-17New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-07-16Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-08-05AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-11-25Parking OnlyThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-08-23Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-09-07Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-09-09Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-09-21AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-09-23Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-01-03Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-01-04Signs (Accessory / Non-Accessory)This permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-01-19SignThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-05-24Parking OnlyThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- L&I violation · 2018-11-23PERMB- INSTALL FIRE SUPP SYSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2006-11-07BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2018-11-21BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2018-12-31BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2019-01-31BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- License · 2024-06-19Fednuts 1909 Sansom St LLC: Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2026-06-18Fednuts 1909 Sansom St LLC: Food Preparing and Serving business license marked expiredA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2023-06-0519R Chestnut Partners LP: Rental landlord or residential registration initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2023-01-06GOLDIE 4 LLC: Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2022-08-24KNP Holdings LLC (Cavanaugh's Rittenhouse): Food Preparing and Serving (30+ SEATS) business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2022-03-06TSR19, LLC (Federal Donuts @ The Harper): Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2025-05-04TSR19, LLC (Federal Donuts @ The Harper): Food Preparing and Serving business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2019-11-14Barry's Bootcamp Pennsylvania, LLC: Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- Certification · 2021-10-13Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2021-10-26Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2022-10-13Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2022-10-27Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-10-10Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-10-18Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-06-30Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-10-07Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-04-17Emergency and Standby Power Systems CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-05-31Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-10-07Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2026-04-06Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2026-05-31Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2026-06-30Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Appeal · 2017-12-05Building standards appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
- CertificationSpecial Hazards Certification
- LicenseFednuts 1909 Sansom St LLC: Food Preparing and Serving business license marked expired
- CertificationSpecial Hazards Certification
- CertificationSprinkler Certification
- CertificationFire Alarm Certification
- CertificationSpecial Hazards Certification
- LicenseTSR19, LLC (Federal Donuts @ The Harper): Food Preparing and Serving business license marked inactive
- CertificationEmergency and Standby Power Systems Certification
- CertificationFire Alarm Certification
- CertificationSpecial Hazards Certification
- LicenseFednuts 1909 Sansom St LLC: Food Preparing and Serving business license initially issued
- CertificationSprinkler Certification
- CertificationFire Alarm Certification
- License19R Chestnut Partners LP: Rental landlord or residential registration initially issued
- PermitParking Only
- LicenseGOLDIE 4 LLC: Food Preparing and Serving business license initially issued
- CertificationSprinkler Certification
- CertificationFire Alarm Certification
- LicenseKNP Holdings LLC (Cavanaugh's Rittenhouse): Food Preparing and Serving (30+ SEATS) business license initially issued
- LicenseTSR19, LLC (Federal Donuts @ The Harper): Food Preparing and Serving business license initially issued
- PermitSign
- PermitSigns (Accessory / Non-Accessory)
- PermitAddition and/or Alterations
- CertificationSprinkler Certification
- CertificationFire Alarm Certification
- PermitAddition and/or Alteration
- PermitAlterations
- PermitAddition and/or Alterations
- PermitAddition and/or Alterations
- PermitAddition and/or Alteration
- PermitParking Only
- PermitAlterations
- PermitAddition and/or Alteration
- PermitNew Construction
- PermitNew Construction
- PermitRough-In
- PermitNew Construction
- PermitNew Construction
- PermitUse
- LicenseBarry's Bootcamp Pennsylvania, LLC: Food Preparing and Serving business license initially issued
- PermitPlumbing
- PermitElectrical
- PermitAdministrative
- PermitAdministrative
- PermitAdministrative
- PermitSuppression
- PermitNew construction
- PermitMechanical
- PermitAdministrative
- PermitAdministrative
- PermitAdministrative
- PermitPlumbing
- PermitAmend for conversion
- PermitElectrical
- PermitSuppression
- PermitNew Construction
- AppealBuilding standards appeal
- PermitMechanical
- PermitSuppression
- InspectionBP_BLDG
- PermitUse
- PermitMajor alteration
- PermitPlumbing
- InspectionBP_BLDG
- PermitMechanical
- L&I violationPERMB- INSTALL FIRE SUPP SYS
- InspectionBP_BLDG
- PermitElectrical
- PermitSuppression
- PermitPlumbing
- PermitPlumbing
- PermitNew construction
- AppealBuilding standards appeal
- PermitAdministrative
- PermitDemolition
- PermitUse
- PermitZoning
- PermitUse
- PermitZoning/use
- PermitDemolition
- PermitPlumbing
- InspectionBC INSP (likely: building-code inspection)
Verify the public record
Property tax
$86,092/year estimated property tax
2026 taxable assessment $6,150,300 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.
OPA has published a 2027 assessment of $63,711,200. It is not the 2026 billed-year value.
Payments, credits, interest, and the current amount due are maintained by the City.
OPA 8810215022026 OPA taxes $6,150,300 of $61,503,000 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.
See the assessment math →Historical delinquency sources No current conclusion
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Property report
Commercial property
Apartment building, recorded in the City's multi-family category. The public record and owner trail follow.
Recorded owner
Who's behind it
19r Chestnut Partners LP · corporate / LLC owner
• Owns 2 properties across Philadelphia under this name, assessed at $65M combined
• Tax bills mail to 110 S 19th St, Philadelphia PA, 19102
• Holds an active rental license for this address
Block context
100 block of S 19th St. Compare parcels, ownership, and public-record history.
See the whole block →Next door: 114 S 19th St · 116 S 19th St
L&I license dates · data through Jul 25, 2026
Business licenses at this address Latest pull
What L&I has registered at this OPA parcel, newest initial license date first.
Food Preparing and Serving · Initial issue date Jun 19, 2024 · Terminal license date Jun 18, 2026
Food Preparing and Serving · Initial issue date Jan 6, 2023 · Filed expiration Jan 5, 2027
Food Preparing and Serving (30+ SEATS) · Initial issue date Aug 24, 2022 · Filed expiration Aug 23, 2027
Food Preparing and Serving · Initial issue date Mar 6, 2022 · Terminal license date May 4, 2025
Food Preparing and Serving · Initial issue date Nov 14, 2019 · Filed expiration Nov 13, 2026
Landlord and residential filings
These are property registrations or landlord filings, not businesses operating at this address.
Rental · Initial issue date Jun 5, 2023 · Filed expiration Jul 23, 2027
A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.
Open every source row 82 dated rows
- CertificationSpecial Hazards Certification
Certification BC-2026-018645 · Certified
Expires 2027-06-30
- License terminal eventFednuts 1909 Sansom St LLC: Food Preparing and Serving business license marked expired
License 0954488 · Expired
License event. Registration does not prove present operation or storefront occupancy.
- CertificationSpecial Hazards Certification
Certification BC-2026-015868 · Certified
Expires 2027-05-31
- CertificationSprinkler Certification
Certification BC-2026-019813 · Certified
Expires 2027-04-06
- CertificationFire Alarm Certification
Certification BC-2025-031529 · Certified
Expires 2026-10-07
- CertificationSpecial Hazards Certification
Certification BC-2025-014771 · Certified
Expires 2026-05-31
- License terminal eventTSR19, LLC (Federal Donuts @ The Harper): Food Preparing and Serving business license marked inactive
License 889065 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- CertificationEmergency and Standby Power Systems Certification
Certification BC-2025-011434 · Certified
Expires 2026-04-17
- CertificationFire Alarm Certification
Certification BC-2024-028158 · Certified
Expires 2025-10-07
- CertificationSpecial Hazards Certification
Certification BC-2024-019302 · Certified
Expires 2025-06-30
- License issue eventFednuts 1909 Sansom St LLC: Food Preparing and Serving business license initially issued
License 0954488 · Expired
License event. Registration does not prove present operation or storefront occupancy.
- CertificationSprinkler Certification
Certification BC-2023-023146 · Certified
Expires 2024-10-18
- CertificationFire Alarm Certification
Certification BC-2023-021538 · Certified
Expires 2024-10-10
- License issue event19R Chestnut Partners LP: Rental landlord or residential registration initially issued
License 0957097 · Active
License event. Registration does not prove present operation or storefront occupancy.
- PermitParking Only
Permit ZP-2023-005052 · Issued
IN EXISTING UNDERGROUND GARAGE. SIZES AND LOCATIONS AS SHOWN IN PLAN.
- License issue eventGOLDIE 4 LLC: Food Preparing and Serving business license initially issued
License 913993 · Active
License event. Registration does not prove present operation or storefront occupancy.
- CertificationSprinkler Certification
Certification BC-2022-017934 · Certified
Expires 2023-10-27
- CertificationFire Alarm Certification
Certification BC-2023-006560 · Certified
Expires 2023-10-13
- License issue eventKNP Holdings LLC (Cavanaugh's Rittenhouse): Food Preparing and Serving (30+ SEATS) business license initially issued
License 903968 · Active
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventTSR19, LLC (Federal Donuts @ The Harper): Food Preparing and Serving business license initially issued
License 889065 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitSign
Permit GP-2022-000063 · Completed
For the installation of two accessory wall signs. Size and location per Philadelphia Historic Commission approved plans.
- PermitSigns (Accessory / Non-Accessory)
Permit ZP-2021-012402 · Completed
FOR THE ERECTION OF TWO (2) WALL SIGNS: SIGN 1: "FEDERAL DONUTS" @ 3-3.5' X 4' = 13 SQ FT, SIGN 2: "GOLDIE" @ 9'1" X 1' 8.25" = 15 SQ FT; ACCESSORY TO TWO (2) TAKE OUT RESTAURANTS; SIZE AND LOCATION AS SHOWN ON THE APPLICATION/PLAN.
- PermitAddition and/or Alterations
Permit FP-2021-003189 · Completed
INSTALL 2 ANSUL R102 WET SYSTEMS See MP-2021-004205 (CP-2021-002491)
- CertificationSprinkler Certification
Certification BC-2022-000210 · Certified
Expires 2022-10-26
- CertificationFire Alarm Certification
Certification BC-2021-005983 · Certified
Expires 2022-10-13
- PermitAddition and/or Alteration
Permit EP-2021-007614 · Completed
Turn empty storefront into two restaurant in the Pearl Building, utilize existing building power. Provide electric for kitchen, extend existing Fire Alarm as shown as per APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE. **DRAWINGS NOTED FOR SHOWROOM WINDOW RECEPTS(210.62)**
- PermitAlterations
Permit PP-2021-011919 · Completed
Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018.
- PermitAddition and/or Alterations
Permit MP-2021-004205 · Completed
FOR THE INSTALLATON OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATE DUCTWORK FOR A SIT DOWN RESTAURANT. MECHANICAL SCOPE TO INCLUDE THE INSTALLION OF FIVE (5) KITCHEN HOODS RANGING FROM 4'-0" TO 4'-6" WITH ASSOCIATED DUCTWORK WITH AN EXHAUST FAN AND MAKE UP AIR FAN. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. APPLIANCES TO BE INSTALLED IN MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
- PermitAddition and/or Alterations
Permit FP-2021-002462 · Completed
**Existing Philadelphia Historic Property** EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. *No exterior work permitted as part of this permit as per PHC* Relocate (35) Sprinkler Heads (CP-2021-002491)
- PermitAddition and/or Alteration
Permit CP-2021-002491 · Completed
FOR INTERIOR FIT OUT ON THE GROUND FLOOR, INCLUDING INTERIOR PARTITIONS AND INTERIOR FINISHES, TO CREATE TWO (2) TENANTS USED AS TAKEOUT RESTAURANTS, PER APPROVED PLANS.
- PermitParking Only
Permit ZP-2020-009392 · Issued
FOR THE ESTABLISHMENT AND DOCUMENTATION OF AN OFF-SITE PARKING AGREEMENT
- PermitAlterations
Permit PP-2020-003890 · Completed
Furnish and install sanitary, sanitary vent and domestic water piping. Furnish and install 2 floor drains, 3 Indirect waste, 2 sinks, 1 laundry drain, 2 lavatories, 2 water closets and 3 water heaters, as per plans
- PermitAddition and/or Alteration
Permit EP-2020-004542 · Completed
Install communications wiring. Scope of Work document "Service order" attached.
- PermitNew Construction
Permit 1056012 · Completed
INSTALL NEW 200AMP FEEDER FROM LANDLORD PROVIDED ENCLOSED CIRCUIT BREAKER TO PANEL LOCATION. INSTALL 2-120/208 VOLT PH 400 AMP PANELS AND 1-120/240 VOLT 3PH 150 AMP PANEL, INSTALL 1-45 KVA TRANSFORMER AND 1-112.5 KVA TRANSFORMER, INSTALL LIGHTING, RE INSTALL FIRE ALARM AS PER DRAWINGS AS PER NFPA 72.
- PermitNew Construction
Permit 1055720 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of 25 Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans.
- PermitRough-In
Permit 1056012-RI · Completed
INSTALL NEW 200AMP FEEDER FROM LANDLORD PROVIDED ENCLOSED CIRCUIT BREAKER TO PANEL LOCATION. INSTALL 2-120/208 VOLT PH 400 AMP PANELS AND 1-120/240 VOLT 3PH 150 AMP PANEL, INSTALL 1-45 KVA TRANSFORMER AND 1-112.5 KVA TRANSFORMER, INSTALL LIGHTING, RE INSTALL FIRE ALARM AS PER DRAWINGS AS PER NFPA 72.
- PermitNew Construction
Permit 1051677 · Completed
FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTUER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
- PermitNew Construction
Permit 1036939 · Completed
FOR NEW CONSTRUCTION FIT-OUT OF A GROUP B (MEDICAL AND HEALTH CENTER) ON THE GROUND FLOOR FACING SANSOM STREET WITHIN AN UNDER-CONSTRUCTION MIXED-USE HIGH-RISE BUILDING, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING TO BE FULLY SPRINKLERED AS PER NFPA 13. SEE AP#819389 FOR NEW CONSTRUCTION PERMIT.
- PermitUse
Permit 1037577 · COMPLETED
USE SPACE,("RETAIL A") IN AN EXISTING BUILDING AS MEDICAL AND HEALTH CENTER. NO CHANGE IN HEIGHT OR SQUARE FOOTAGE. NO SIGN WITH THIS PERMIT.
- License issue eventBarry's Bootcamp Pennsylvania, LLC: Food Preparing and Serving business license initially issued
License 829278 · Active
License event. Registration does not prove present operation or storefront occupancy.
- PermitPlumbing
Permit 1002172 · COMPLETED
FURNISH AND INSTALL SANITARY, SANITARY VENT AND DOMESTIC VENT PIPING.FURNISH AND INSTALL BATHROOM,SHOWERS AND BREAK ROOM PLUMBING FIXTURES PER 2004 PHILADELPHIA PLUMBING CODE (GYM)
- PermitElectrical
Permit 1005007 · COMPLETED
3 PANELS (2) 100A 225A DOWN STREAM LL SUPPLIED 400AMP 4800 PANEL AND 25KVA TRANSFORMER EQUIPMENT POWER BUILDING LIGHTING FIRE ALARM LOW VOLTAGE DATA SOUND WIRE PULLING ONLY TERMINATIONS AS PER 2017 NEC AND NFPA 72 (CC DIST)
- PermitAdministrative
Permit 1009407 · COMPLETED
TCO 4TH FLOOR
- PermitAdministrative
Permit 1009425 · COMPLETED
TCO 9TH FLOOR
- PermitAdministrative
Permit 1002363 · COMPLETED
TEMPORARY CERTIFICATE OF OCCUPANCY
- PermitSuppression
Permit 1000350 · COMPLETED
FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.
- PermitNew construction
Permit 990829 · COMPLETED
FOR NEW CONSTRUCTION FIT-OUT OF A GROUP A-3 TENANT (HEALTH CLUB W/ACCESSORY RETAIL SALES) ON THE PARTIAL GROUND FLOOR FACING SANSOM STREET WITHIN AN UNDER-CONSTRUCTION MIXED-USE HIGH-RISE BUILDING, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING TO BE FULLY SPRINKLERED AS PER NFPA 13; NO WORK WITHIN COMMON AREAS; SEE AP#819389 FOR NEW CONSTRUCTION PERMIT; SEE AP#973642 FOR USE REGISTRATION PERMIT.
- PermitMechanical
Permit 991974 · COMPLETED
FOR THE INSTALLATION OF A NEW MECHANICAL/HVAC SYSTEM THROUGHOUT A NEW GROUP A-3 TENANT SPACE ("BARRY'S BOOTCAMP") ON THE FIRST FLOOR OF A NEW MIXED-USE HIGH-RISE BUILDING (FACING SANSOM ST) INCLUDING ALL ASSOCIATED DUCTWORK, REGISTERS, DIFFUSERS, GRILLES, APPLIANCES, ETC., AS PER PLANS; SEE AP#990829 FOR NEW CONSTRUCTION FIT-OUT OF TENANT SPACE.
- PermitAdministrative
Permit 995257 · COMPLETED
TEMPORARY CERTIFICATE OF OCCUPANCY
- PermitAdministrative
Permit 985788 · COMPLETED
TEMPORARY CERTIFICATE OF OCCUPANCY
- PermitAdministrative
Permit 979897 · COMPLETED
TEMOORARY CERTIFICATE OF OCCUPANCY
- PermitPlumbing
Permit 945691 · COMPLETED
FITOUT FOR SUITE 200 TO BE USED AS A BUSINESS AND PROFESSIONAL OFFICE;MIXED USE HIGH-RISE BUILDING; 24 STORY BLDG INCLUDES GROUND FLOOR LOBBY AND SHELL RETAIL SPACES, 2ND FLOOR SHELL RETAIL SPACE,;PLUMBING SYSTEM FROM CORE BUILDING CONNECTIONS TO NEW BATHROOMS AND PANTRY AREA. FURNISH WC, LAVS, EWC FOR OFFICE BATHROOM. THE INSTALLATION WILL COMPLY WITH 2004 PHILA PLUMBING CODE.
- PermitAmend for conversion
Permit 934325 · Expired
AMEND NEW CONSTRUCTION PERMIT NO. 819389 TO DOCUMENT THE CREATION OF AN EXIT ACCESS CORRIDOR FOR ADJACENT PROPERTIES AT 1900 & 1910 CHESTNUT STREET AND TO DOCUMENT ALL PARTY WALL BREACHES AS PER APPROVED PLANS AND BBS VARIANCE NO. 36522.
- PermitElectrical
Permit 949772 · COMPLETED
ELECTRICAL SERVICE PANEL, HVAC EQUIPMENT LINES, LIGHTING FIXTURES, LIGHTING CORNERS, DECEPTACLES, EXIT AND EMERGENCY LIGHTING, FURNITURE PARTITION LINES, ADD FIRE ALARM DEVICES TO THE EXISTING SYSTEM. PER NEC 2014 PER NFPA 72
- PermitSuppression
Permit 954383 · COMPLETED
RELOCATE (20) SPRINKLER HEADS IN 1ST FLOOR BAKERY
- PermitNew Construction
Permit 954563 · Completed
FURNISH & INSTALL 145 CAT5E PLENUM CABLE FOR VOICE & DATA LONGEST RUN 150' AS PER NEC 2008
- AppealBuilding standards appeal
Appeal 36522 · CLOSED · APPROVED
Related permit 934325 · ON 02/06/2019, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #934325.
- PermitMechanical
Permit 944689 · COMPLETED
FOR MECHANICAL ALTERAITONS TO SIOTE 200 TO INCLUDE NEW EXHAUST FANS, MECHANICAL EQUIPMENT, REGISTERS/DIFFUSERS AND ASSOCIATED DUCTWORK, AS PER APPROVED PLANS. **NEW EXTERIOR WORK LIMITED TO THE INSTALLATION OF ONE (1) ROOFTOP UNIT, AS PER PHC**
- PermitSuppression
Permit 949310 · COMPLETED
RELOCATE 49 EXISTING SPRINKLER HEADS (COMMERCIAL)
- InvestigationBP_BLDG
Case 664824 · PASSED
The cited inspection visit was marked passed.
- PermitUse
Permit 942357 · COMPLETED
INTERIOR FITOUT FOR SUITE 200 TO BE USED AS A BUSINESS AND PROFESSIONAL OFFICE IN A NEW BUILDING, AS PER APPROVED PLANS.
- PermitMajor alteration
Permit 935806 · COMPLETED
INTERIOR FITOUT FOR SUITE 200 TO BE USED AS A BUSINESS AND PROFESSIONAL OFFICE IN A NEW BUILDING, AS PER APPROVED PLANS.
- PermitPlumbing
Permit 930701 · COMPLETED
GROUND FLOOR (CAFE-DELI) PROVIDE TENNANT FITOUT AS PER PLANS (BP 819389) FURNISH & INSTALL PLUMBING SANITARY, VENT & DOMESTIC WATER PIPING. INSTALL HOT WATER HEATER AND PLUMBING FIXTURES ADA BATHROOM & CONNECT KITCHEN EQUIPMENT
- InvestigationBP_BLDG
Case 664824 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitMechanical
Permit 894951 · COMPLETED
INSTALLATION OF HVAC SYSTEM FOR NEW MIXED USE HIGH-RISE BUILDING TO INCLUDE DUCTWORK, EXHAUST FANS, MECHANICAL UNITS, (1,289) REGISTER/DIFFUSERS AND SMOKE CONTROL SYSTEM AS PER APPROVED PLANS.
- ViolationPERMB- INSTALL FIRE SUPP SYS
Case 664824 · Violation 4912353 · Code A-301.1/27 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBP_BLDG
Case 664824 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitElectrical
Permit 884347 · COMPLETED
INSTALL 400AMP TEMP & 6000AMP MAIN SRVC,SUBSTATION,BUS DUCTS, PANELS, FEEDERS, TEMP LTS,EM GEN,4 ELEVATOR LINES,SWITCHES,LIGHTS,RECEPTS,120V SMOKES, CABLE TV,PHONE LINES CONNECT TO MECH EQUIP & CONTROLS AS PER 2008 NEC (CC DISTRICT) INSTALL FIRE ALARM SYSTEM AS PER NFPA72
- PermitSuppression
Permit 894763 · COMPLETED
FOR INSTALLING ONE TEMPORARY 6" DRY STANDPIPE FROM FDC ON THE STREET SIDE WITH FIRE DEPARTMENT HOSE CONNECTIONS AT ACCESSIBLE LOCATIONS ADJACENT TO USABLE STAIRS TO EACH ADDITIONAL FLOOR BEING BUILT FOR SAFEGUARDS DURING CONSTRUCTION AS PER IBC SECTION 3311.
- PermitPlumbing
Permit 887348 · COMPLETED
TO INSTALL 10" DUCTILE IRON PIPE COMPLETE IWTH TRAP INLETS AND TRENCH DRAIN - "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
- PermitPlumbing
Permit 852189 · COMPLETED
F & I A NEW PLUMBING SYSTEM 1071 FIXTURES IN A NEW 24 STORY BUILDING. SOIL, VENT & DOMESTIC WATER PIPING AND ,CURB TRAP,FAI,WATER SERV& HOUSE DRAIN PA20180451445 SELF CERTIFICATION NO LONGER ACCEPTED ALL TRENCHES IN EXCESS OF 5 FT MUST HAVE APPROVED SHORING AT THE TIME OF INSPECTION. **ROUGHIN FOR INSIDE ONLY**
- PermitNew construction
Permit 819389 · COMPLETED
NEW CONSTRUCTION OF A RETAIL AND RESIDENTIAL MIXED USE HIGH-RISE BUILDING WITH ACCESSORY UNDERGOUND PARKING PER APPROVED PLANS AND BBS VARIANCE NO 32180. 24 STORY BLDG INCLUDES GROUND FLOOR LOBBY AND SHELL RETAIL SPACES, 2ND FLOOR SHELL RETAIL SPACE, AMENITIES SPACES AND ROOF TERRACE WITH POOL, 3RD FLOOR ROOF GARDEN AND RESIDENTIAL SPACE, 4TH THROUGH 24TH FLOOR RESIDENTIAL SPACES WITH (183) TOTAL UNITS, AND PENTHOUSE LEVEL MECHANICAL SPACES. BUILDING REQUIRED TO BE FULLY SPRINKLERED PER NFPA 13, WITH WATER CURTAINS PER BBS VARIANCE AND STANDPIPES IN EXIT STAIRWAYS PER NFPA 14 *SEPARATE PERMITS REQUIRED FOR FIT OUT FOR GROUND FLOOR AND SECOND FLOOR RETAIL SPACES**SEE A/P 788751 FOR FOUNDATION WORK* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION**
- AppealBuilding standards appeal
Appeal 32180 · CLOSED · APPROVED
Related permit 819389 · ON 11/7/2017, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #819389.
- PermitAdministrative
Permit 827761 · COMPLETED
AMEND PERMIT #788751 TO INCLUDE ASSEMBLY AND DISASSEMBLY OF A TOWER CRANE AS PART OF CONSTRUCTION OF HIGH-RISE BUILDING AS PER APPROVED PLANS AND DOCUMENTATION.
- PermitDemolition
Permit 828484 · COMPLETED
PUMP OUT CLEAN AND REMOVE 1,000 GALLON #2 FUEL OIL UNDERGROUND STORAGE TANK UST IN EXCAVATION. PETROLEUM PRODUCTS WILL BE REMOVED AND UST CLEANED PRIOR TO REMOVAL. CONFORMITY SOIL SAMPLE WILL BE PERFORMED BELOW UST. UST CLOSURE REPORT WILL BE ISSUED POST CLOSURE. CONTINGENCY PLAN IN PLACE IN CASE CONTAMINATED SOILS DISCOVERED DURING UST CLOSURE. ALL WORK COMPLETED IN ACCORDANCE WITH PADEP UST REMOVAL GUIDELINES UST IS UNREGULATED FUEL OIL TANK ALL FUEL OIL DISPOSED OF AT ELDREDGE INC PA RESIDUAL WASTE PROCESSING FACILITY PERMIT
- PermitUse
Permit 760325 · COMPLETED
FOR THE ESTABLISHMENT OF UNITY OF USE TO CREATE ONE(1) LOT FOR ZONING PURPOSES WITH RESTRICITIVE COVENANTS, AGREEMENTS AND EASEMENTS TO BE RECORDED BY DEED TO BIND CURRENT AND FUTURE OWNERS OF THE CONTIGUOUS FOUR (4) PARCELS TO PRESERVE THEW UNITY OF USE AND THE LEGALITY OF THE ENTIRE PROJECT THAT STEMS FROM SINGLE ZONING LOT TREATMENT.
- PermitZoning
Permit 712386 · COMPLETED
FOR THE LOT ADJUSTMENT TO CREATE ONE(1) LOT "PARCEL A" FROM THREE(3) OPA ACCOUNTS ( 110 SOUTH 19TH STREET, 1910 R CHESTNUT STREET AND 112 SOUTH 19TH STREET). ( SEE APP# 708917 FOR PLANS)
- PermitUse
Permit 657211 · COMPLETED
FOR THE ESTABLISHMENT OF UNITY OF USE TO CREATE ONE(1) LOT FOR ZONING PURPOSES WITH RESTRICITIVE COVENANTS, AGREEMENTS AND EASEMENTS TO BE RECORDED BY DEED TO BIND CURRENT AND FUTURE OWNERS OF THE CONTIGUOUS FIVE(5) PARCELS TO PRESERVE THEW UNITY OF USE AND THE LEGALITY OF THE ENTIRE PROJECT THAT STEMS FROM SINGLE ZONING LOT TREATMENT.
- PermitZoning/use
Permit 607533 · COMPLETED
FOR THE COMPLETE DEMOLITION OF AN EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN APPLICATION. FOR USE TO VACANT LOT. **SEE A/P 607532 FOR PLANS**
- PermitDemolition
Permit 607534 · COMPLETED
FOR THE COMPLETE DEMOLITION OF AN EXISTING ATTACHED ONE (1) STORY, MASONRY AND CONCRETE COMMERCIAL BUILDING [112 S 19TH ST] AND THE ADJACENT SEMI-DETACHED [ALLEY ON ONE SIDE] THREE (3) STORY, MASONRY AND WOOD COMMERCIAL BUILDING [110 S 19TH ST]. ALL PERMITTED DEMOLITION ACTIVITY TO BE IN ACCORDANCE WITH APPROVED SITE SAFETY DEMOLITION PLAN & SUCH PLAN TO BE MAINTAINED ON SITE AT ALL TIMES IN ACCORDANCE WITH CODE BULLETIN B-1302. FULL SIDEWALK CLOSURE REQUIRED AS REFLECTED ON APPROVED SITE PLAN AND IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE STREET CLOSURE PERMIT REQUIRED PRIOR TO START OF WORK. ANY DEVIATION WILL REQUIRE AN AMENDED BUILDING PERMIT. *ASBESTOS REMOVAL REQUIRED*
- PermitPlumbing
Permit 609350 · COMPLETED
REMOVE TRAP AND SEAL LATERAL *PART OF DEMO*(COMMERCIAL)PA 1 CALL 2015-1202890 SELF CERTIFICATION'S ARE NO LONGER PERMITTED","ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
- InvestigationBC INSP (likely: building-code inspection)
Case 89149 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
Where this comes from
- Assessment, spec sheet & owner: OPA Property Assessments, Office of Property Assessment
- Sales & deed history: Realty Transfer Tax records, Recorder of Deeds
- Permits, violations & inspections: L&I Property History · Atlas
- Tax delinquency snapshot · June 2022: Real Estate Tax Delinquencies, Dept. of Revenue
- Historical tax ledger & liens · through 2016: Real Estate Tax Balances, Dept. of Revenue
- Current property-tax balance: Verify with Philadelphia Revenue
- Zoning appeals: L&I & Zoning Board appeals
- Imagery: Street photo © Google · Aerial © Esri, Maxar
Methodology & freshness
This report was assembled Jul 27, 2026, 4:20 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)