Land report
1147 N Delaware Ave
1143-51 N Delaware Ave Holdings LLC
3 violation rows marked OPEN in 1 active case
The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.
Notice Of Violation
- Failure To Perform Special Inspections
A-402.4 - New Structure
A-301.1/1 - Vacant Properties- General
PM15-901.1
OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.
Verify the public record
Property tax
Property-tax estimate unavailable
The taxable assessment was unavailable. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.
Payments, credits, interest, and the current amount due are maintained by the City.
OPA 181289940The assessment did not include a usable taxable value.
Historical delinquency sources No current conclusion
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Land report
Vacant land
Vacant land. Deeds, ownership, zoning, and the public-source record follow.
Block context
1100 block of N Delaware Ave. Compare parcels, ownership, and public-record history.
See the whole block →Next door: 1145 N Delaware Ave · 1145 N Delaware Ave
L&I license dates · data through Jul 25, 2026
Business licenses at this address Latest pull
What L&I has registered at this OPA parcel, newest initial license date first.
Food Preparing and Serving (30+ SEATS) · Initial issue date Jun 20, 2003 · Terminal license date Apr 30, 2004
A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.
Open every source row 91 dated rows
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-099149 · PASSED
The cited inspection visit was marked passed.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-099520 · PASSED
The cited inspection visit was marked passed.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitMajor Demolition
Permit DP-2021-002038 · Completed
Sub Demolition Permit for CF-2021-099149. For the complete demolition of a commercial property as part of the City of Philadelphia demolition program. *Add'l specs: Demolish entire building (18 units) concrete walls to remain, all vegetation within lot line to be removed. Exterior to be cleaned and graded within lot line. Erosion control mat with seed on all exposed earth. Install an 8 ft high chain link fence around perimeter @ 10' off building line. Schedule 40 post shall be used. Schedule 20 pipe for top and bottom rails. #9 gauge wire shall be used for fence.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationVACANT & OPEN
Case CF-2021-099520 · Violation VI-2021-071683 · Code PM15-108.2 · COMPLIED
Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationL&I investigation
Case CF-2021-099520 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationID STRUCTURE
Case CF-2021-099149 · Violation VI-2021-071407 · Code PM15-110.1 · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSTRUCTURAL DETERIORATION
Case CF-2021-099149 · Violation VI-2021-071410 · Code PM15-304.1(E) · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationROOF DEFICIENCIES
Case CF-2021-099149 · Violation VI-2021-071409 · Code PM15-304.1(H) · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationID WORK SCHEDULE REQ
Case CF-2021-099149 · Violation VI-2021-071408 · Code PM15-110.7 · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationROOF DEFICIENCIES
Case CF-2021-099149 · Violation VI-2021-071400 · Code PM15-304.1(H) · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationID WORK SCHEDULE REQ
Case CF-2021-099149 · Violation VI-2021-071399 · Code PM15-110.7 · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationID STRUCTURE
Case CF-2021-099149 · Violation VI-2021-071398 · Code PM15-110.1 · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSTRUCTURAL DETERIORATION
Case CF-2021-099149 · Violation VI-2021-071397 · Code PM15-304.1(E) · COMPLIED
Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationL&I investigation
Case CF-2021-099149 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2021-022689 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationFAILURE TO PERFORM SPECIAL INSPECTIONS
Case CF-2021-022689 · Violation VI-2021-017407 · Code A-402.4 · OPEN
The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.
- ViolationNEW STRUCTURE
Case CF-2021-022689 · Violation VI-2021-017406 · Code A-301.1/1 · OPEN
The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.
- ViolationVACANT PROPERTIES- GENERAL
Case CF-2021-022689 · Violation VI-2021-017408 · Code PM15-901.1 · OPEN
The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.
- PermitNew Construction
Permit 1008993 · Expired
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES-INSTALL TWO(2) NEW HVAC SYSTEMS; 60000BTU FURNANCE WITH 3TON A/C EACH 95% AND 26000BTU FURNANCE WITH 2.5TON A/C UNITS EACH 95% INCLUDING ALL NECESSARY DUCT WORK. For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.(NO PENETRATION OF RATED ASSEMBLIES - UNIT TO BE SELF CONTAINED)
- PermitNew Construction or Additions
Permit 1009052 · Expired
INSTALL HOUSE DRAIN,STACK,WASTE AND WATER LINES TO 5-TOILETS,5-LAVS,3-SHOWERS,1-TUB,1-KITCHEN SINK,1-WASHER AND 1-WATER HEATER.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004
- PermitNew Construction or Additions
Permit 1009053 · Expired
INSTALL HOUSE DRAIN,STACK,WASTE AND WATER LINES TO 5-TOILETS,5-LAVS,3-SHOWERS,1-TUB,1-KITCHEN SINK,1-WASHER AND 1-WATER HEATER.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004
- PermitNew Construction or Additions
Permit 1009054 · Expired
INSTALL HOUSE DRAIN,STACK,WASTE AND WATER LINES TO 5-TOILETS,5-LAVS,3-SHOWERS,1-TUB,1-KITCHEN SINK,1-WASHER AND 1-WATER HEATER.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004
- PermitNew Construction
Permit 1008933 · Expired
NEW ELECTRICAL WIRING/DEVICES 200AMP SERVICE BONDING AND GROUNDING AS PER 2014 NEC
- PermitNew Construction
Permit 1008931 · Expired
NEW ELECTRICAL WIRING/DEVICES 200AMP SERVICE BONDING AND GROUNDING AS PER 2014 NEC
- PermitNew Construction
Permit 1008910 · Expired
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Install 2 indoor 92% 75000 BTUs direct vent furnaces with two 2 1/2TON coils, 2 outdoor condensers and fully ducted supply and return air with condensers mounted on a pad in the rear yard.
- PermitNew Construction
Permit 1008914 · Expired
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Install 2 indoor 92% 75000 BTUs direct vent furnaces with two 2 1/2TON coils, 2 outdoor condensers and fully ducted supply and return air with condensers mounted on a pad in the rear yard.
- PermitNew Construction
Permit 1008915 · Expired
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Install 2 indoor 92% 75000 BTUs direct vent furnaces with two 2 1/2TON coils, 2 outdoor condensers and fully ducted supply and return air with condensers mounted on a pad in the rear yard.
- PermitNew Construction
Permit 1002374 · Expired
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- PermitNew Construction
Permit 1002376 · Expired
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
- PermitNew Construction or Additions
Permit 1000175 · Expired
INSTALL PLUMBING SYSTEM; DRAIN, STACK, FIXTURES; FIVE(5) TOILETS, FIVE(5) LAVS, THREE(3) SHOWERS, ONE(1) TUB, ONE(1) KITCHEN SINK, ONE(1) WASHER, ONE(1) HOT WATER HEATER AS PER PHILADELPHIA 2014 PLUMBING CODE.
- PermitNew Construction or Additions
Permit 1000187 · Expired
INSTALL PLUMBING SYSTEM; DRAIN, STACK, FIXTURES; FIVE(5) TOILETS, FIVE(5) LAVS, THREE(3) SHOWERS, ONE(1) TUB, ONE(1) KITCHEN SINK, ONE(1) WASHER, ONE(1) HOT WATER HEATER AS PER PHILADELPHIA 2014 PLUMBING CODE.
- PermitNew Construction
Permit 1000212 · Expired
NEW WIRE CONNECT TO NEW 200AMP SERVICE ALL BONDING AND GROUNDING AS PER 2014 NEC
- PermitNew Construction or Additions
Permit 974021 · Expired
ROUGH IN & FINISH 1-4 PC MASTER BATH, 2-3 PC BATHS, 2-POWDER ROOMS, 1-KITCHEN SINK, 1-WASHER BOX, HOT WATER TANK, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004
- PermitNew Construction or Additions
Permit 974019 · Expired
ROUGH IN & FINISH 1-4 PC MASTER BATH, 2-3 PC BATHS, 2-POWDER ROOMS, 1-KITCHEN SINK, 1-WASHER BOX, HOT WATER TANK, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004
- PermitNew Construction or Additions
Permit 974016 · Expired
ROUGH IN & FINISH 1-4 PC MASTER BATH, 2-3 PC BATHS, 2-POWDER ROOMS, 1-KITCHEN SINK, 1-WASHER BOX, HOT WATER TANK, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004
- PermitNew Construction or Additions
Permit 965988 · Expired
NEW CONSTRUCTION: EXTERIOR PLUMBING; SITE WORK;FAMILY TOWNHOUSES;13- 5" CURB TRAPS, 4" VENTS, 4" HOUSE DRAINS. 13- 1" WATER SERVICES.
- PermitNew Construction
Permit 957379 · Expired
INSTALL 200AMP SERVICE & PANEL WITH A 100AMP SUB PANEL INSTALL WIRING FOR POWER & LIGHTING INSTALL ALL SWITCHES OUTLETS, INSTALL SMOKE DETECTORS INSTALL TEL/CATV WIRING ALL WIRING AS PER 2008 NEC EAST DISTRICT
- PermitNew Construction
Permit 957381 · Expired
INSTALL 200AMP SERVICE & PANEL WITH A 100AMP SUB PANEL INSTALL WIRING FOR POWER & LIGHTING INSTALL ALL SWITCHES OUTLETS, INSTALL SMOKE DETECTORS INSTALL TEL/CATV WIRING ALL WIRING AS PER 2008 NEC EAST DISTRICT
- PermitNew Construction
Permit 957382 · Expired
INSTALL 200AMP SERVICE & PANEL WITH A 100AMP SUB PANEL INSTALL WIRING FOR POWER & LIGHTING INSTALL ALL SWITCHES OUTLETS, INSTALL SMOKE DETECTORS INSTALL TEL/CATV WIRING ALL WIRING AS PER 2008 NEC EAST DISTRICT
- PermitNew Construction
Permit 923904 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910249 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923040 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS; SEE AP#877479 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923041 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910238 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitAmend for conversion
Permit 948188 · Expired
TO AMEND PREVIOUSLY ISSUED FIRE SUPPRESSION PERMITS AP#923040, 923041, 923044, 923087, 923089, 923091, 923094, 923096, 923097, 923203, 923205, 923206, AND 923904 TO REMOVE REFERENCE TO "2" BACKFLOW WITHIN BASEMENT" FROM ALL PERMITS AND HAVE ALL PERMITS READ AS FOLLOWS: "FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS."
- PermitNew Construction
Permit 923094 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910240 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923044 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910239 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923096 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910241 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923097 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910242 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923087 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910243 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923089 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910244 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923091 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910245 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923203 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910246 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923205 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910247 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 923206 · Expired
FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R USING A NEW 4" FIRE SERVICE LINE USING A 2" BACKFLOW WITHIN THE BASEMENT CONNECTING TO A NEW 6" PRIVATE FIRE MAIN WITH SHARED 6" BACKFLOW INSTALLED WITHIN METER PIT FOR A NEW FOUR (4) STORY ATTACHED STRUCTURE WITH A ROOF DECK ACCESS STRUCTURE TO BE USED AS GROUP R-3 (SINGLE-FAMILY DWELLING W/PARKING GARAGE), AS PER PLANS UNDER AP#923040; SEE AP#910248 FOR BUILDING PERMIT; SERVICE LINES BASED OFF PWD-APPROVED UTILITY PLAN DATED 4/25/18; DRY HEADS AND LISTED HEAT-TRACED PIPING TO BE INSTALLED WITHIN UNCONDITIONED AREAS.
- PermitNew Construction
Permit 943589 · Expired
INSTALL 200AMP SERVICE & PANEL WITH A 100AMP SUB PANEL INSTALL WIRING FOR POWER & LIGHTING INSTALL ALL SWITCHES OUTLETS, INSTALL SMOKE DETECTORS INSTALL TEL/CATV WIRING ALL WIRING AS PER 2008 NEC
- PermitNew Construction
Permit 943591 · Expired
INSTALL 200AMP SERVICE & PANEL WITH A 100AMP SUB PANEL INSTALL WIRING FOR POWER & LIGHTING INSTALL ALL SWITCHES OUTLETS, INSTALL SMOKE DETECTORS INSTALL TEL/CATV WIRING ALL WIRING AS PER 2008 NEC
- PermitAmend for conversion
Permit 931251 · Expired
AMEND PERMIT #877479 AND SUBSEQUENT CHILD PERMITS TO CHANGE THE EXTERIOR WALLS AND SEPERATION WALLS OF ALL 19 PREVIOUSLY APPROVED TOWNHOUSES TO INDUSTRIALIZED ELEMENTS UNDER PA INDUSTRIALIZED HOUSING PROGRAM APPROVED BY THIRD PARTY AGENCY NTA, INC. IN ACCORDANCE WITH PA DCED REGULATIONS.
- PermitNew Construction
Permit 932513 · Expired
INSTALLATION OF 2 INDOOR DIRECT VENT FURNACES WITH 2 COILS, 2 OUTDOOR CONDENSERS AND FULLY DUCTED SUPPLY AND RETURN AIR.
- PermitNew Construction
Permit 932511 · Expired
INSTALLATION OF 2 INDOOR DIRECT VENT FURNACES WITH 2 COILS, 2 OUTDOOR CONDENSERS AND FULLY DUCTED SUPPLY AND RETURN AIR.
- PermitNew Construction
Permit 877479 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910238 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910239 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910240 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910241 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910242 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910243 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910244 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910245 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910246 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910247 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910248 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910249 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910250 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910251 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910252 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910253 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910254 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitNew Construction
Permit 910255 · Expired
FOR THE ERECTION OF AN ATTACHED STRUCRUE WITH ROOF DECK ACCESSED BY PILOTHOUSE FOR A SINGLE FAMILY DWELLING BUILDING WITH TWO INTERIOR ACCESSORY PRKING SPACES, ONE OF A TOTAL NINETEEN FAMILY TOWNHOUSES WITH THIRTY-EIGHT(38) ACCESSORY PARKING GARAGE ACCESSED BY A COMMON REAR DRIVE-AISLE WITH THREE(3) BICYCLE SPACES UNDER ROOF AT FIRST FLOOR IN AN ACCESSIBLE ROUTE ( UNIT# C) .SIZE AND LOCATION AS SHOWN IN THE APPLICATION.STRUCTURE TO BE FULLY SPRINKLERED,SEPARATE PERMITS TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.SEE AP#877479 FOR ALL APPROVED PLAN/DOCUMENTATION.
- PermitFoundation
Permit 877462 · Expired
PERMIT IS FOR FOUNDATION ONLY AND CONSISTS OF EXCAVATION, GRADE BEAMS, CONCRETE WALLS AND SLABS ONLY. PILES ARE ALREADY INSTALLED UNDER PERMIT AP# 815751. SPECIAL INSPECTIONS SHALL BE PERFOMED BY AMBRIC TECHNOLOGY CORPORATION.
- License terminal eventRIVER RESTAURANT INC: Food Preparing and Serving (30+ SEATS) business license marked inactive
License 209782 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventRIVER RESTAURANT INC: Food Preparing and Serving (30+ SEATS) business license initially issued
License 209782 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventELLER MEDIA COMPANY: Outdoor Advertising Sign L&I license filing marked inactive
License 300092 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventELLER MEDIA COMPANY: Outdoor Advertising Sign L&I license filing initially issued
License 300092 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
Where this comes from
- Assessment, spec sheet & owner: OPA Property Assessments, Office of Property Assessment
- Sales & deed history: Realty Transfer Tax records, Recorder of Deeds
- Permits, violations & inspections: L&I Property History · Atlas
- Tax delinquency snapshot · June 2022: Real Estate Tax Delinquencies, Dept. of Revenue
- Historical tax ledger & liens · through 2016: Real Estate Tax Balances, Dept. of Revenue
- Current property-tax balance: Verify with Philadelphia Revenue
- Zoning appeals: L&I & Zoning Board appeals
- Imagery: Street photo © Google · Aerial © Esri, Maxar
Methodology & freshness
This report was assembled Jul 27, 2026, 8:54 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)