Commercial property report
1318-24 Chestnut St
4 stories32,983 sqftCMX5built 1900
Individual owner on record
3 violation rows marked OPEN in 2 active cases
The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.
Notice Of Violation
- Required Graffiti Removal
PM13-311.1 - Clip Violation Notice
CP-01
Periodic Testing
- Periodic Testing
F-901.6.4
OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.
Assessment and City record timeline
The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.
Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $8,245,800. It is not yet the billed-year tax basis.
- OPA assessment · 2016$1.7M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2017$1.7M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2019$5.1M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2020$5.3M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2021$5.3M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2022$5.3M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2023$5.8M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2024$5.8M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2025$5.8M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2026$5.8M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2027$8.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- Permit · 2008-05-27UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-02-23Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2011-07-20Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2012-01-25Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2012-04-24Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2012-08-17UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2012-11-14Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2012-12-05PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-01-14SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-01-14MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-02-12MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-02-15AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-03-04ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-07-11SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-07-11SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-12-09ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-12-19UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-06-03PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-06-26Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2014-08-08PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-08-20ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-08-21PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-10-14MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-06-17PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-07-22PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-01-30DemolitionThis permit category usually covers partial or complete removal work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-03-08ZoningThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-03-27ZoningThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-07-13UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2017-10-05Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2018-01-10MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-01-11ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-01-12PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-03-14SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-03-20MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-03-29PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-06-25SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-04-26Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2019-08-30UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-11-29AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-12Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-05-20Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- L&I violation · 2007-04-14CLIP VIOLATION NOTICEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2007-04-14EXT-GRAFFITIA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2007-04-14EXT-GRAFFITIA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2007-04-14CLIP VIOLATION NOTICEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2007-04-14HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2007-04-14HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- L&I violation · 2009-10-28EXT-GRAFFITIA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2009-10-28CLIP VIOLATION NOTICEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2014-06-21FIRE-ELECT MULTIPLUG PROHIBA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2014-06-21FIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)Fire extinguisher needs inspection and a current service tagHow L&I violations and orders work ↗
- L&I violation · 2014-06-21TOILET REPR/REPLC-NRA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2014-06-21HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- L&I violation · 2019-06-29REQUIRED GRAFFITI REMOVALA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2019-06-29CLIP VIOLATION NOTICEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2019-08-16SPECIAL ASSEMBLY OCC LOA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2019-08-16LO SIGNA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2019-08-16OBTAIN LIC INDICATED (Obtain the license identified in the notice)The shorthand does not identify the license type; open the case notice for that detail.How L&I violations and orders work ↗
- Inspection · 2019-08-16CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2020-02-14FIRE ESCAPE REPORTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14FDC SIGNAGE REQUIREDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14FIRE SUPPRESSION CERTIFICATIONA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14GENERAL REQ.- CITE CODE SECTIOA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14STORAGE IN BUILDINGSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14LABELINGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14OPEN JUNCTION BOXESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14SECURING COMPRESSED CYLINDERSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14DRAPERIES/CURTAINSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14ELECTRICAL -HAZARDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14MEANS OF EGRESS OBSTRUCTIONA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14WORKING SPACE/CLEARANCEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14LOCKING DEVICESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14FIRE RESISTANCE RATINGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14WET CHEMICAL SYSTEM TESTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2020-02-14EXIT SIGN ILLUMINATIONA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2020-02-14CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2020-02-14CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2021-04-26TENTS/MEMBRANE STRUCTURESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2021-04-26L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2025-04-29EXTERIOR AREA GRAFFITIA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2025-04-29L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2025-12-08PERIODIC TESTINGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2025-12-08L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2007-04-24HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2007-05-02HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2014-07-29HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2019-09-25CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2020-08-06L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2020-08-14L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2020-10-26L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2021-01-21L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2021-03-04L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2021-03-12L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2021-06-15L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2025-03-20L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2026-06-05L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- License · 2022-10-271318 BRAUHAUS INC: Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2022-10-291318 BRAUHAUS INC: Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2020-08-071318 BRAUHAUS INC: Special Assembly Occupancy business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2022-10-051318 BRAUHAUS INC: Special Assembly Occupancy business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2020-06-161318 BRAUHAUS INC: Sidewalk Cafe (Temporary) L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2023-02-281318 BRAUHAUS INC: Sidewalk Cafe (Temporary) L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- Certification · 2021-02-15Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-07-20Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-12-28Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-12-28Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-02-28Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-02-18Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-11-11Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2026-01-16Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Appeal · 2008-05-21Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2012-03-07Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2012-08-15Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2013-12-04Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2017-05-17Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2019-09-17RB_LIRBA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
- InspectionL&I investigation
- CertificationSprinkler Certification
- L&I violationPERIODIC TESTING
- InspectionL&I investigation
- CertificationSpecial Hazards Certification
- L&I violationEXTERIOR AREA GRAFFITI
- InspectionL&I investigation
- InspectionL&I investigation
- CertificationSprinkler Certification
- CertificationSprinkler Certification
- CertificationSpecial Hazards Certification
- CertificationSpecial Hazards Certification
- CertificationSpecial Hazards Certification
- License1318 BRAUHAUS INC: Sidewalk Cafe (Temporary) L&I license filing marked inactive
- License1318 BRAUHAUS INC: Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive
- License1318 BRAUHAUS INC: Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued
- License1318 BRAUHAUS INC: Special Assembly Occupancy business license marked inactive
- InspectionL&I investigation
- L&I violationTENTS/MEMBRANE STRUCTURES
- InspectionL&I investigation
- InspectionL&I investigation
- InspectionL&I investigation
- CertificationFire Alarm Certification
- InspectionL&I investigation
- InspectionL&I investigation
- InspectionL&I investigation
- License1318 BRAUHAUS INC: Special Assembly Occupancy business license initially issued
- InspectionL&I investigation
- License1318 BRAUHAUS INC: Sidewalk Cafe (Temporary) L&I license filing initially issued
- PermitAddition and/or Alterations
- PermitAddition and/or Alteration
- L&I violationFIRE ESCAPE REPORT
- L&I violationFDC SIGNAGE REQUIRED
- L&I violationFIRE SUPPRESSION CERTIFICATION
- L&I violationGENERAL REQ.- CITE CODE SECTIO
- L&I violationSTORAGE IN BUILDINGS
- L&I violationLABELING
- L&I violationOPEN JUNCTION BOXES
- L&I violationSECURING COMPRESSED CYLINDERS
- L&I violationDRAPERIES/CURTAINS
- L&I violationELECTRICAL -HAZARD
- L&I violationMEANS OF EGRESS OBSTRUCTION
- L&I violationWORKING SPACE/CLEARANCE
- L&I violationLOCKING DEVICES
- L&I violationFIRE RESISTANCE RATING
- L&I violationWET CHEMICAL SYSTEM TEST
- L&I violationEXIT SIGN ILLUMINATION
- InspectionCI INSP
- InspectionCI INSP
- PermitAdministrative
- InspectionCI INSP
- AppealRB_LIRB
- PermitUse
- L&I violationSPECIAL ASSEMBLY OCC LO
- L&I violationLO SIGN
- L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
- InspectionCI INSP
- L&I violationREQUIRED GRAFFITI REMOVAL
- L&I violationCLIP VIOLATION NOTICE
- PermitMajor alteration
- PermitSuppression
- PermitPlumbing
- PermitMechanical
- PermitSuppression
- PermitPlumbing
- PermitElectrical
- PermitMechanical
- PermitMajor alteration
- PermitUse
- AppealZoning board appeal
- PermitZoning
- PermitZoning
- PermitDemolition
- PermitPlumbing
- PermitPlumbing
- PermitMechanical
- PermitPlumbing
- PermitElectrical
- PermitPlumbing
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- PermitMajor alteration
- L&I violationFIRE-ELECT MULTIPLUG PROHIB
- L&I violationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)
- L&I violationTOILET REPR/REPLC-NR
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- PermitPlumbing
- PermitUse
- PermitElectrical
- AppealZoning board appeal
- PermitSuppression
- PermitSuppression
- PermitElectrical
- PermitAdministrative
- PermitMechanical
- PermitSuppression
- PermitMechanical
- PermitPlumbing
- PermitMajor alteration
- PermitUse
- AppealZoning board appeal
- PermitMajor alteration
- AppealZoning board appeal
- PermitMajor alteration
- PermitMajor alteration
- L&I violationEXT-GRAFFITI
- L&I violationCLIP VIOLATION NOTICE
- PermitMajor alteration
- PermitUse
- AppealZoning board appeal
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- L&I violationCLIP VIOLATION NOTICE
- L&I violationEXT-GRAFFITI
- L&I violationEXT-GRAFFITI
- L&I violationCLIP VIOLATION NOTICE
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
Verify the public record
Property tax
$80,785/year estimated property tax
2026 taxable assessment $5,771,200 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.
OPA has published a 2027 assessment of $8,245,800. It is not the 2026 billed-year value.
Payments, credits, interest, and the current amount due are maintained by the City.
OPA 8824972022026 taxable assessment equals the full assessed value.
Historical delinquency sources No current conclusion
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Where the record looks off
Conflicts in City paperwork. Flags on the data, not the property.
Philadelphia records use 1900 as a stand-in when the real construction year was never documented. Treat the age as unknown, not as 120+ years.
Property report
Commercial property
Commercial, recorded in the City's commercial category. The public record and owner trail follow.
3 open violations
Block context
1300 block of Chestnut St. Compare parcels, ownership, and public-record history.
See the whole block →Next door: 1312 Chestnut St · 1326-28 Chestnut St
L&I license dates · data through Jul 25, 2026
Business licenses at this address Latest pull
What L&I has registered at this OPA parcel, newest initial license date first.
Special Assembly Occupancy · Initial issue date Aug 7, 2020 · Terminal license date Oct 5, 2022
A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.
Open every source row 117 dated rows
- InvestigationL&I investigation
Case CF-2025-131113 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- CertificationSprinkler Certification
Certification BC-2026-016335 · Certified
Expires 2027-01-16
- ViolationPERIODIC TESTING
Case CF-2025-131113 · Violation VI-2025-095098 · Code F-901.6.4 · OPEN
The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.
- InvestigationL&I investigation
Case CF-2025-131113 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- CertificationSpecial Hazards Certification
Certification BC-2025-029723 · Certified
Expires 2026-11-11
- ViolationEXTERIOR AREA GRAFFITI
Case CF-2025-035113 · Violation VI-2025-026522 · Code PM15-302.9 · SVN ISSUED
Resolution: SVN ISSUED
- InvestigationL&I investigation
Case CF-2025-035113 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case 724521 · PASSED
The cited inspection visit was marked passed.
- CertificationSprinkler Certification
Certification BC-2025-014339 · Certified
Expires 2026-02-18
- CertificationSprinkler Certification
Certification BC-2024-014674 · Deficient
- CertificationSpecial Hazards Certification
Certification BC-2024-000241 · Certified
Expires 2024-12-28
- CertificationSpecial Hazards Certification
Certification BC-2024-000242 · Certified
Expires 2024-12-28
- CertificationSpecial Hazards Certification
Certification BC-2023-015319 · Certified
Expires 2024-07-20
- License terminal event1318 BRAUHAUS INC: Sidewalk Cafe (Temporary) L&I license filing marked inactive
License 843492 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal event1318 BRAUHAUS INC: Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive
License 909394 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue event1318 BRAUHAUS INC: Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued
License 909394 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal event1318 BRAUHAUS INC: Special Assembly Occupancy business license marked inactive
License 848215 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- InvestigationL&I investigation
Case CF-2021-032047 · PASSED
The cited inspection visit was marked passed.
- ViolationTENTS/MEMBRANE STRUCTURES
Case CF-2021-032047 · Violation VI-2021-024394 · Code FC-13-105.6.13 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationL&I investigation
Case CF-2021-032047 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case 724559 · PASSED
The cited inspection visit was marked passed.
- InvestigationL&I investigation
Case 724559 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- CertificationFire Alarm Certification
Certification BC-2021-000728 · Certified
Expires 2022-02-15
- InvestigationL&I investigation
Case 724521 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case 724521 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case 702329 · PASSED
The cited inspection visit was marked passed.
- License issue event1318 BRAUHAUS INC: Special Assembly Occupancy business license initially issued
License 848215 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- InvestigationL&I investigation
Case 702329 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- License issue event1318 BRAUHAUS INC: Sidewalk Cafe (Temporary) L&I license filing initially issued
License 843492 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitAddition and/or Alterations
Permit FP-2020-000364 · Expired
EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - For the Relocation of ten(10) Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans.
- PermitAddition and/or Alteration
Permit 1048711 · Expired
FOR LEVEL I INTERIOR ALTERATION TO INCLUDE FINISH WORK AND FURNISH TO THE LOWER LEVEL OF EXISTING RESTAURANT. BUILDING IS FULLY SPRINKLERED.
- ViolationFIRE ESCAPE REPORT
Case 724521 · Violation 211989876 · Code FC-13-101115 · CLOSED
Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.
- ViolationFDC SIGNAGE REQUIRED
Case 724521 · Violation 211989874 · Code FC-13-912.4 · CLOSED
Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.
- ViolationFIRE SUPPRESSION CERTIFICATION
Case 724521 · Violation 211989872 · Code FC-13-915.1A · CLOSED
Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.
- ViolationGENERAL REQ.- CITE CODE SECTIO
Case 724521 · Violation 211989819 · Code FC-13-912 · CLOSED
Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.
- ViolationSTORAGE IN BUILDINGS
Case 724559 · Violation 211990120 · Code FC-13-315.2 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationLABELING
Case 724559 · Violation 211990121 · Code FC-13-605.31 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationOPEN JUNCTION BOXES
Case 724559 · Violation 211990122 · Code FC-13-605.6 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSECURING COMPRESSED CYLINDERS
Case 724559 · Violation 211990073 · Code FC-13-300353 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationDRAPERIES/CURTAINS
Case 724559 · Violation 211990072 · Code FC-13-807.1 · COMPLIED
Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationELECTRICAL -HAZARD
Case 724559 · Violation 211990071 · Code PM15-604.3 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationMEANS OF EGRESS OBSTRUCTION
Case 724559 · Violation 211990116 · Code FC-13-1003.3 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationWORKING SPACE/CLEARANCE
Case 724559 · Violation 211990117 · Code FC-13-605.3 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationLOCKING DEVICES
Case 724559 · Violation 211990118 · Code FC-13-100823 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationFIRE RESISTANCE RATING
Case 724559 · Violation 211990119 · Code FC-13-703 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationWET CHEMICAL SYSTEM TEST
Case 724559 · Violation 211990075 · Code FC-13-904.5 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationEXIT SIGN ILLUMINATION
Case 724559 · Violation 211990076 · Code FC-13-1007.2 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationCI INSP
Case 724559 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 724521 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitAdministrative
Permit 1010254 · COMPLETED
NO CONSTRUCTION OR CHANGE IN USE. LAWFUL OCCUPANCY CERTIFICATION SIGNAGE FOR THE BASEMENT MEZZINE AND 1ST FLOOR
- InvestigationCI INSP
Case 702329 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- AppealRB_LIRB
Appeal 38136 · CLOSED · Withdrawn
THE DUMPSTERS ARE LOCATED ON OUR PROPERTY WE HAVE 3 RESTAURANT CONCEPTS WITHIN 4 CONSOLIDATED LOT LINES (1313,-20-22-24), WE CANNOT STORE INTERNALLY, MUST FIND A SOLUTION.
- PermitUse
Permit 1006797 · COMPLETED
FOR A NIGHT CLUB AND PRIVATE CLUB OF AN EXISTING SIT-DOWN RESTAURANT ON CELLAR,1ST FLOOR AND MEZZANINE WITH VACANT UPPER FLOORS IN AN EXISTING STRUCTURE. NO SIGN ON THIS APPLICATION.
- ViolationSPECIAL ASSEMBLY OCC LO
Case 702329 · Violation 211968484 · Code 09-703.1/1 · COMPLIED
Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationLO SIGN
Case 702329 · Violation 5194938 · Code FC-13-1004.2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
Case 702329 · Violation 5194939 · Code LO-1 · COMPLIED
The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationCI INSP
Case 702329 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationREQUIRED GRAFFITI REMOVAL
Case 633408 · Violation 211948391 · Code PM13-311.1 · OPEN
The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.
- ViolationCLIP VIOLATION NOTICE
Case 633408 · Violation 211948429 · Code CP-01 · OPEN
The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.
- PermitMajor alteration
Permit 954568 · COMPLETED
FOR THE INSTALLATION OF METAL I-BEAMS FOR SUPPORT IN BASEMENT AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ALL OTHER WORK.
- PermitSuppression
Permit 888568 · COMPLETED
- FOR THE INSTALLATION OF NEW WET CHEMICAL KITCHEN FIRE SUPPRESSION SYSTEM AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.
- PermitPlumbing
Permit 863408 · COMPLETED
INSTALL 1 1/2" WATER SERVICE WITH WATTS LF0009M2QT BACKFLOW PREVENTOR-PA1#20180881295-"SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
- PermitMechanical
Permit 854007 · COMPLETED
INSTALLATION OF 7 AIR HANDLERS, 7 HEAT PUMPS, DUCT SYSTEM THROUGHOUT. INSTALLATION OF EXHAUST AIR AND OUTSIDE AIR INTAKE DUCT.INSTALLATION OF REQUIRED LINESETS FOR HEAT PUMP ROOF PLACEMENT. ALL DUCT TO BE SEALED BY MANUFACTURER AND MASTIC IN FIELD. INSTALLATION AS PER SMACNA REGULATIN AS PER ENGINEER
- PermitSuppression
Permit 828860 · COMPLETED
FOR THE INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM WITH BACKFLOW PREVENTER AS PER NFPA 13 CONNECTING TO THE EXISTING FIRE SERVICE LINE. ALL WORK SHALL BE DONE IN ACCORDDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.
- PermitPlumbing
Permit 827205 · COMPLETED
43 PLUMBING FIXTURES WITH PIPING FOR RESTUARANT RENOVATION- THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMB - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE
- PermitElectrical
Permit 835261 · COMPLETED
INSTALL WIRING AND DEVICES FOR LIGHTS,POWER,HVAC,COOKING COMMUNICATION AND NEW 400AMP 120/208 VOLT SERVICE PER 2008 NEC (RESTAURANT)NEW FIRE ALARM PER NFPA 72
- PermitMechanical
Permit 838831 · COMPLETED
FOR THE INSTALLATION OF TWO (2) COMMERCIAL KITCHEN HOODS (12'-0" AND A 15'-0") WITH ASSOCIATED DUCTWORK AND CIRCULATING SYSTEM. SEPARATE PERMIT REQUIRED FOR SUPPRESSION SYSTEM.
- PermitMajor alteration
Permit 812168 · COMPLETED
FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS AND INTERIOR FINISHES TO CREATE A RESTAURANT ON PARTIAL BASEMENT, FIRST FLOOR AND MEZZANINE LEVEL, AS PER APPROVED PLANS. EXTERIOR ALTERATIONS TO INCLUDE NEW STOREFRONT AND FACADAE ALTERATIONS, PER CITY PLANNING COMMISSION APPROVAL AND APPROVED PLANS. NO EXTERIOR SIGNAGE ON THIS PERMIT.
- PermitUse
Permit 758152 · COMPLETED
APPLICATION IS FOR THE PROPOSED USE OF A SIT-DOWN RESTAURANT ON CELLAR, 1ST FLOOR AND MEZZANINE WITH VACANT UPPER FLOORS IN AN EXISTING STRUCTURE.CERTIFICATE OF OCCUPANCY IS REQUIRED AND BUILDING PERMIT SHALL BE OBTAINED FOR ISSUING CERTIFICATE OF OCCUPANCY.
- AppealZoning board appeal
Appeal 30227 · OPEN · Granted
Related permit 758152 · SPECIAL EXCEPTION FOR THE PROPOSED USE OF A SITDOWN RESTAURANT ON CELLAR, 1ST FLOOR AND MEZZANINE WITH VACANT UPPER FLOORS IN AN EXISTING STRUCTURE
- PermitZoning
Permit 764191 · COMPLETED
FOR RELOCATION OF LOT LINE TO CREATE ONE LOT FROM TWO (2) DEEDED LOTS (1318-1320 CHESTNUT ST AND 1322-1324 CHESTNUT ST). SIZE AND LOCATION AS SHOW ON THE APPLICATION.
- PermitZoning
Permit 757973 · COMPLETED
FOR RELOCATION OF LOT LINE TO CREATE ONE LOT FROM TWO (2) DEEDED LOTS (1318-1320 CHESTNUT ST AND 1322-1324 CHESTNUT ST). SIZE AND LOCATION AS SHOW ON THE APPLICATION.
- PermitDemolition
Permit 755198 · COMPLETED
INTERIOR DEMO OF NON LOAD BEARING PARTITIONS ONLY.(COMMERCIAL)
- PermitPlumbing
Permit 626596 · COMPLETED
INSTALL REAR 5" LAT-5" CURB TRAP SOIL MAIN INTO BASEMENT PA1# 2015-1971383 - "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
- PermitPlumbing
Permit 618217 · EXPIRED
REPLACE CURB TRAP,FAI AND LATERAL PA20151661157 (COMM)SELF CERTIFICATION'S ARE NO LONGER PERMITTED","ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
- PermitMechanical
Permit 567858 · COMPLETED
HVAC WITH DW, ALL WITHIN ONE TENANT SPACE. INSTALL 4 UNTIS NONE OVER 2000 CFM
- PermitPlumbing
Permit 552381 · COMPLETED
PLUMBING FOR RESTAURANT BAR KITCHEN AND BATHROOMS 6 WC,4 LAVS,1 URINAL,1 MOP SINK,5 SINKS,4 FS, 1 FD AND MISC. INDIRECT WASTE LINES (RESTAURANT) - WORK WILL COMPLY WITH THE APPROVED PLANS
- PermitElectrical
Permit 548502 · COMPLETED
INSTALL WIRING AND DEVICES TO PROVIDE ELECTRIC NEEDS TO NEW BRU RESTAURANT IN BASEMENT OF EXISTING BUILDING. THIS WORK INCLUDES WIRING THE KITCHEN EQUIPMENT,WALK-IN BOX,TIE INTO EXISTING FIRE ALARM AND HVAC WIRING PER 2008 NEC (RESTAURANT)
- PermitPlumbing
Permit 554640 · COMPLETED
REPAIR MAIN DRAIN SIDEWALK AREA (RESTAURANT) PA20142040866 SELF-CERIFICATION'S ARE NO LONGER PERMITTED - ALL EXCAVATIONS & PLUMBING TRENCHES IN EXCESS OF 5' IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 438377 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
- PermitMajor alteration
Permit 530911 · COMPLETED
ALTERATIONS AND INTERIOR DEMO FOR LOWER LEVEL, STRUCTURAL WORK AND MODIFICATIONS NEW COMMUNICATING STAIR CONSTRUCTION, FIT OUT, FURNISHINGS, NEW EQUIPMENT, BATHROOMS, PARTITIONS, FINISHES FOR RESTAURANT SPACE EXTENSION OF 1ST FLOOR INTO LOWER LEVEL. 2ND - 4TH UPPER FLOORS VACANT PER AFFIDAVIT. RESTAURANT FIRE AREAS REQUIRE SPRINKLERS. ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS, SIGNS, HOOD & ANSUL. AMEND PERMIT FOR SP INSPECTIONS AGENCY
- ViolationFIRE-ELECT MULTIPLUG PROHIB
Case 438377 · Violation 3226017 · Code FC-605.4/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)
Case 438377 · Violation 3226018 · Code FC-906.2/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationTOILET REPR/REPLC-NR
Case 438377 · Violation 3226019 · Code PM-504.3/14 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 438377 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitPlumbing
Permit 540376 · COMPLETED
REPLACE SECTION OF SOIL LINE IN SIDEWALK AREA PA20141540535 (COMM) SELF-CERIFICATION'S ARE NO LONGER PERMITTED - ALL EXCAVATIONS & PLUMBING TRENCHES IN EXCESS OF 5' IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION
- PermitUse
Permit 502044 · COMPLETED
USE OF CELLAR AS A SIT DOWN RESTAURANT AS PART OF AN EXISTING TAKE OUT RESTAURANT WITH SEATING ON THE FIRST FLOOR
- PermitElectrical
Permit 510242 · COMPLETED
INSTALLATION OF 4 EXTERIOR CAMERAS PER 2008 NEC (RESTAURANT)
- AppealZoning board appeal
Appeal 21650 · CLOSED · Granted
Related permit 502044 · PERMIT USE OF A CELLAR TO A SIT DOWN RESTAURANT AS PART OF AN EXISTING TAKE OUT RESTAURANT WITH SEATING ON THE FIRST FLOOR WITH ACCESSORY STORAGE, NOT TO EXCEED 25% IN THE CELLAR, UPPER FLOORS VACANT (USE REGISTRATION PERMIT REQUIRED PRIOR
- PermitSuppression
Permit 477092 · COMPLETED
INSTALLATION OF NEW TWO AND ONE-HALF INCH (2-1/2") DOUBLE CHECK VALVE BACKFLOW PREVENTION DEVICE ON AN EXISTING FIRE SERVICE LINE.
- PermitSuppression
Permit 477093 · COMPLETED
INSTALLATION OF NEW THREE INCH (3") DOUBLE CHECK VALVE BACKFLOW PREVENTION DEVICE ON AN EXISTING FIRE SERVICE LINE.
- PermitElectrical
Permit 439523 · COMPLETED
INSTALL ELECTRIC AND FIRE ALARM PER 2008 NEC & NFPA 72 (RESTAURANT)
- PermitAdministrative
Permit 440802 · COMPLETED
FOR LEVEL II INTERIOR/EXTERIOR ALTERATIONS AS SHOWN PER APPROVED PLAN TO INCLUDE ACCESSIBLE SEATING THROUGHOUT AND ACCESSIBLE RESTROOMS AS SHOWN PER APPROVED PLANS.ALL ALTERATIONS TO BE DONE PER APPROVED PLANS PER BBS LETTER (CAL # 19644) DATED 01/18/13. NO SIGNS ON THIS PERMIT. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK.
- PermitMechanical
Permit 440774 · COMPLETED
NEW INSTALLATION OF HVAC DUCTWORK,DIFFUSERS, 4 GOODMAN 90% 100,000 BTU GAS FURNACE WITH GOODMAN 14 DEER 5 TON CONTROL AIR SYSTEMS, ALL NEW DUCT WORK FOR EACH SYSTEM WITH CEILING DIFFUSERS, 4 - 5 TON AC UNIT WITH SIT ON BACK SIDE OF RESTAURANT, ACCESSORY MECHANICALS AND MECHANICAL PIPING. INSTALL TYPE 1 KITCHEN HOOD, EXHAUST DUCT AND ROOF HOOD EXHAUST FAN. ADDITIONAL PERMIT IS REQUIRED FOR ELECTRICAL, PLUMBING, ANSUL SUPPRESSION SYSTEM FOR HOOD.
- PermitSuppression
Permit 446222 · COMPLETED
FOR THE INSTALLATION OF A WET CHEMICAL SUPPRESSION SYSTEM IN ACCORDANCE WITH UL 300 WITH FOURTEEN (14) FLOW POINTS. SUPPRESSION SYSTEM TO SERVE A 10'-0" COMMERCIAL KITCHEN HOOD AS APPROVED IN PERMIT #446218.
- PermitMechanical
Permit 446218 · COMPLETED
FOR THE INSTALLATION OF A 10'-0" COMMERCIAL KITCHEN HOOD WITH ASSOCIATED DUCTWORK AND CIRCULATING SYSTEM.
- PermitPlumbing
Permit 439292 · COMPLETED
ROUGHIN OF CAST IRON AND COPPER FOR RESTAURANT, 3 TOILETS, 2 UR, 2 LAVS, 6 FL DRAINS, 3 FL SINKS, 2 WAITRESS STATIONS, 1 GLASS WASHER, 1 BAR SINK, 1 ICE SINK, 1 HAND SINK, 1 FOOD PREP SINK, 1 3 COMP SINK, 1 MOP SINK, 1 DISHWASHER (RESTAURANT)
- PermitMajor alteration
Permit 435141 · COMPLETED
FOR INTERIOR/EXTERIOR ALTERATIONS AS SHOWN PER APPROVED PLAN TO INCLUDE ACCESSIBLE SEATING THROUGHOUT AND ACCESSIBLE RESTROOMS AS SHOWN PER APPROVED PLANS. NO SIGNS ON THIS PERMIT. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK.
- PermitUse
Permit 414462 · COMPLETED
FOR A TAKE OUT RESTAURANT WITH SEATING ON THE FIRST FLOOR WITH ACCESSORY STORAGE, NOT TO EXCEED 25% IN THE CELLAR, UPPER FLOORS VACANT (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY). NO SIGN ON THIS PERMIT.
- AppealZoning board appeal
Appeal 18497 · CLOSED · Granted
Related permit 414462 · PERMIT FOR A TAKE OUT RESTAURANT WITH SEATING ON THE FIRST FLOOR WITH ACCESSORY STORAGE, NOT TO EXCEED 25% IN THE CELLAR, UPPER FLOORS VACANT (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY).
- PermitMajor alteration
Permit 384945 · COMPLETED
NEW STAIRS TO BE CONSTRUCTED FROM 1ST TO VACANT 2ND FLOOR.NEW PARTITION WALL AS PER PLAN.
- AppealZoning board appeal
Appeal 16743 · CLOSED · Dismissed
Related permit 372386 · CERTIFICATE FOR A NIGHTCLUB TO INCLUDE LIVE ENTERTAINMENT, D.J. MUSIC, DANCING BY PATRONS AND PREPARATION AND SERVING OF COLD BEVERAGES FOR MORE THAN 50 PERSONS IN THE CELLAR OF AN EXISTING BUILDING WITH OTHER USES AS PREVIOUSLY APPROVED.
- PermitMajor alteration
Permit 371824 · COMPLETED
INTERIOR ALTERATIONS TO EXISTING HOISTWAY SHAFT TO INCLUDE INFILL OF EXISTING OPENINGS WITH VERTICAL FIRE-RATED ASSEMBLIES AT THE BASEMENT, FIRST AND SECOND FLOOR LEVELS ONLY. NO EXTERIOR WORK; SEPARATE PERMITS REQUIRED FOR ANY MECHANICAL, ELECTRICAL OR PLUMBING WORK.
- PermitMajor alteration
Permit 348480 · COMPLETED
EXTENDING STOREFRONT FOR VACANT COMMERCIAL SPACE.
- ViolationEXT-GRAFFITI
Case 219006 · Violation 1507290 · Code PM-311.0/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationCLIP VIOLATION NOTICE
Case 219006 · Violation 1507289 · Code CP-01 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- PermitMajor alteration
Permit 199999 · COMPLETED
INSTALL STEEL PER PLANS
- PermitUse
Permit 133162 · COMPLETED
USE PERMIT FOR RESTAURANT - "NO TAKE OUT" ON NON DISPOSABLE WEAR - NO PLASTIC; NO PAPER - ALL FOOD TO BE SERVED ON NON DISPOSABLE WEAR
- AppealZoning board appeal
Appeal 5109 · CLOSED · Granted with conditions
Related permit 133162 · CERTIFICATE FOR AN EAT-IN ONLY RESTAURANT, NO TAKE-OUT, FOOD SERVED ON NON DISPOSABLE WARE, NO MUSIC, NO LIVE ENTERTAINMENT, NO ALCOHOL BEVERAGES- ON THE LOWER LEVEL ON AN EXISTING BUILDING WITH USES AS PREVIOUSLY APPROVED. NO SIGNS ON THI
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 108817 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 108819 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
- ViolationCLIP VIOLATION NOTICE
Case 108817 · Violation 543258 · Code CP-01 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationEXT-GRAFFITI
Case 108817 · Violation 543259 · Code PM-311.0/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationEXT-GRAFFITI
Case 108819 · Violation 543267 · Code PM-311.0/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationCLIP VIOLATION NOTICE
Case 108819 · Violation 543266 · Code CP-01 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 108817 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 108819 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Where this comes from
- Assessment, spec sheet & owner: OPA Property Assessments, Office of Property Assessment
- Sales & deed history: Realty Transfer Tax records, Recorder of Deeds
- Permits, violations & inspections: L&I Property History · Atlas
- Tax delinquency snapshot · June 2022: Real Estate Tax Delinquencies, Dept. of Revenue
- Historical tax ledger & liens · through 2016: Real Estate Tax Balances, Dept. of Revenue
- Current property-tax balance: Verify with Philadelphia Revenue
- Zoning appeals: L&I & Zoning Board appeals
- Imagery: Street photo © Google · Aerial © Esri, Maxar
Methodology & freshness
This report was assembled Jul 27, 2026, 4:49 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)