Apartment building report

1421-23 E Columbia Ave

4 stories16,324 sqftIRMXbuilt 2021

Property at a glanceApartments

1421 East Columbia Ave

2026 assessment
$2.7M OPA value, not a listing price
2027 published assessment
$2.7M Future roll, not the current tax bill
Neighborhood area
Fishtown · East Kensington Approximate · based on ZIP 19125
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $2,718,600. It is not yet the billed-year tax basis.

$0$2.5M$5.0M$2.7M201320162019202220252027
Property assessmentAssessmentTeardownL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record58 events · exact dates, newest first
  1. CertificationSprinkler Certification
  2. CertificationFire Alarm Certification
  3. CertificationSprinkler Certification
  4. CertificationSprinkler Certification
  5. CertificationFire Alarm Certification
  6. CertificationSprinkler Certification
  7. PermitCertificate of Occupancy (CO) (may inclu…
  8. License1421-23 East Columbia Avenue: Rental landlord or residential registration initially issued
  9. PermitNew Construction or Additions
  10. PermitNew Construction
  11. AppealZBA Permit Denial - Variance
  12. PermitChange of Use
  13. PermitNew Construction or Additions
  14. PermitRough-In
  15. PermitNew Construction
  16. PermitPlumbing
  17. PermitNew Construction
  18. AppealZoning board appeal
  19. PermitRough-In
  20. PermitAmend for conversion
  21. PermitNew Construction
  22. PermitZoning/use
  23. PermitDemolition
  24. PermitAlterations
  25. TeardownDemolished
  26. PermitZoning/use
  27. PermitZoning/use
  28. PermitZoning
  29. PermitZoning
  30. AppealZoning board appeal
  31. InspectionEP_ELEC
  32. PermitAdministrative
  33. L&I violationPENALTY- NO ELEC PERM INFO
  34. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  35. L&I violationPERME- REQUIRED TO CORR VIOL
  36. InspectionEP_ELEC
  37. PermitAdministrative
  38. InspectionBP_BLDG
  39. PermitAdministrative
  40. L&I violationWORKMANLIKE- BUILDING CODE
  41. InspectionBP_BLDG
  42. InspectionPP_PLUMB
  43. InspectionPP_PLUMB
  44. PermitAdministrative
  45. PermitPlumbing
  46. L&I violationPENALTY- NO PLUMB PERM INFO
  47. L&I violationPERMP- INST SANITARY PIPE SYS
  48. PermitElectrical
  49. PermitMechanical
  50. PermitSuppression
  51. PermitMajor alteration
  52. PermitZoning/use
  53. PermitDemolition
  54. PermitUse
  55. PermitUse
  56. PermitZoning
  57. PermitAlteration
  58. AppealZoning board appeal

Verify the public record

$3,807/year estimated property tax

2026 taxable assessment $272,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $2,718,600. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881426803
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $272,000 of $2,720,000 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartments, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartments Vacant Land Commer < Acre
Owner
1421 East Columbia Ave
$ / sq ft
$167 above the $147 median for 2,826 apartments parcels citywide
Licensed units
17 active rental license
Interior area
16,324 sqft
Lot size
4,441 sqft
Stories
4
Built
2021
Zoning
IRMX

Recorded owner

Who's behind it

1421 East Columbia Ave · corporate / LLC owner

• Tax bills mail to 30 N 41st St, Philadelphia PA, 19104
• Holds an active rental license for this address

Block context

1400 block of E Columbia Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1419 E Columbia Ave  ·  1417 E Columbia Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 27, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

1421-23 East Columbia AvenueActive

Rental · Initial issue date Jul 20, 2021 · Filed expiration Jul 19, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 56 dated rows
  1. CertificationSprinkler Certification

    Certification BC-2026-019289 · Certified

    Expires 2027-06-11

  2. CertificationFire Alarm Certification

    Certification BC-2026-012362 · Certified

    Expires 2027-03-24

  3. CertificationSprinkler Certification

    Certification BC-2025-018234 · Certified

    Expires 2026-06-18

  4. CertificationSprinkler Certification

    Certification BC-2024-019686 · Certified

    Expires 2025-06-26

  5. CertificationFire Alarm Certification

    Certification BC-2024-010034 · Certified

    Expires 2025-04-01

  6. CertificationSprinkler Certification

    Certification BC-2023-015757 · Certified

    Expires 2024-06-13

  7. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-008195 · Issued

    CERTIFICATE OF OCCUPANCY FOR A FOR MULTI-FAMILY DWELLING USE (17 UNITS).

  8. License issue event1421-23 East Columbia Avenue: Rental landlord or residential registration initially issued

    License 873436 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  9. PermitNew Construction or Additions

    Permit PP-2020-010842 · Completed

    New construction, interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018.

  10. PermitNew Construction

    Permit EP-2020-004394 · Completed

    Install 1200 amp 120/240v 3ph main service. Install 17 gang meter module with built in breakers. Install 400a ct service for house. Install all wiring throughout 17 apartments and common areas. Install addressable fire alarm system throughout as per 2017nec & 2016 nfpa72. install cable tv wiring

  11. AppealZBA Permit Denial - Variance

    Appeal ZP-2020-005727 · Completed · Granted with conditions

    Related permit ZP-2020-005727 · APPLICATION IS FOR A MULTI-FAMILY HOUSEHOLD LIVING (17 DWELLING UNITS) FROM FIRST FLOOR THROUGH FIFTH (5TH) FLOORS WITH INTERIOR PARKING GARAGE FOR FIVE (5) CARS WITH ONE (1) ACCESSIBLE SPACE AS PREVIOUSLY APPROVED STRUCTURE. NO SIGN ON THI

  12. PermitChange of Use

    Permit ZP-2020-005727 · Issued

    Residential - Household Living - Multi-Family

  13. PermitNew Construction or Additions

    Permit PP-2020-007706 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  14. PermitRough-In

    Permit EP-2020-005766 · Completed

    Rough-In Permit for EP-2020-004394 AS PER 2017 NEC

  15. PermitNew Construction

    Permit FP-2020-000428 · Completed

    FOR THE INSTALLATION OF A FOUR (4) INCH FIRE SERVICE LINE WITH BACKFLOW PREVENTOR FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13 WITH STANDPIPES IN THE EXIT STAIRS PER NFPA 14. ALL WORK SHALL BE IN ACCORDANCE WITH THE APPROVED PLANS AND CALCULATIONS.

  16. PermitPlumbing

    Permit 1024089 · ABANDONED

    INSTALL DRAIN AND WATER LINES FROM BASEMENT TO 22 TOILETS, 22 SINKS, 22 TUB/SHOWERS, 14 KITCHEN SINKS, 14 LAUNDRY

  17. PermitNew Construction

    Permit 1033851 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  18. AppealZoning board appeal

    Appeal 39366 · CLOSED · Withdrawn

    Related permit 1016998 · PERMIT FOR THE LEGALIZATION OF HEIGHT (60') OF PREVIOUSLY APPROVED STRUCTURE ON ORANGE STREET (20' WIDE) FRONTAGE FOR A MULTI-FAMILY HOUSEHOLD LIVING (17 DWELLINGS UNITS) FROM FIRST (1ST) FLOOR THROUGH FIFTH (5TH) FLOORS WITH INTERIOR PARKI

  19. PermitRough-In

    Permit 1026634-RI · Cancelled

    COMBINED AUTOMATIC SPRINKLER & CLASS I MANUAL WET STANDPIPE SYSTEMS WITH FOUR (*****************) INCH FIRE SERVICE LINE & BACKFLOW PREVENTION (BFP) ASSEMBLY TO SERVE PREVIOUSLY APPROVED MULTI-FAMILY DWELLING. AUTOMATIC SPRINKLER SYSTEM & STANDPIPE SYSTME INSTALLATION PER NFPA 13/14.

  20. PermitAmend for conversion

    Permit 981475 · Completed

    AMEND PERMIT #943717. TO INCLUDED STRUCTURAL REVISIONS TO THE FOUNDATION AND THE FLOOR/CEILING ASSEMBLIES THROUGHOUT THE STRUCTURE AS PER CLOUDED REVISIONS AND UPDATED STRUCTURAL DETAILS. THIS PERMIT TO ALSO INCLUDE SPECIAL INSPECTION OF POST INSTALLED CONCRETE ANCHORS.

  21. PermitNew Construction

    Permit 943717 · Completed

    FOR THE ERECTION OF A FIVE STORY STRUCTURE WITH ROOF DECK AND ROOF DECK ACCESS STRUCTURE; FOR USE VACANT INDUSTRIAL USE (USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY) WITH INTERIOR PARKING GARAGE FOR FIVE(5) CARS WITH ONE(1) ACCESSIBLE SPACE AND WITH SEVEN(7) 1A CLASS BICYCLE SPACES IN AN ACCESSIBLE ROUTE AT FIRST FLOOR IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING ( 16 DWELLING UNITS). ENTIRE BUILDING TO BE SPRINKELRED PER NFPA 13 AND EQUIPPED WITH A STANDPIPE SYSTEM. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. BUILDING TO BE PROVIDED WITH TYPE B DWELLING UNITS. Amend permit 943717 on 3/11/21 to make the following changes: 1) Convert the vacant commercial space at the 1st floor level to a dwelling unit for a total of (17) dwelling units from the 1st the 5th floor level. 2) In lieu of providing standby power systems per 2702.1.1, horizontal exits in rated barriers are added on all floors above the level of discharge. Per 2018 IBC Section 1009.2.1 exception 1, the elevator is not required to be part of the accessible means of egress when the building is fully sprinklered and horizonal exits are located above the level of discharge. Horizontal exits are provided in accordance with IBC section 1026.

  22. PermitZoning/use

    Permit 947957 · COMPLETED

    FOR THE COMPLETE DEMOLITION OF AN EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS. FOR USE TO VACANT LOT, WITH NEW USES IN NEW STRUCTURE AS PER PERMIT NO. 885714.

  23. PermitDemolition

    Permit 947958 · COMPLETED

    COMPLETE DEMOLITION OF AN EXISTING ATTACHED, ONE-STORY, MASONRY AND CONCRETE VACANT WAREHOUSE BUILDING BY HAND AND MECHANICAL METHODS. SPECIAL INSPECTIONS REQUIRED AND TO BE PERFORMED BY JACK PARISI, PE, OF GEOSTRUCTURES, INC. ALL PERMITTED DEMOLITION ACTIVITY TO BE IN ACCORDANCE WITH APPROVED SITE SAFETY DEMOLITION PLAN & SUCH PLAN TO BE MAINTAINED ON SITE AT ALL TIMES IN ACCORDANCE WITH PHILADELPHIA ADMINISTRATIVE CODE. COMPLETE SIDEWALK CLOSURE REQUIRED AS REFLECTED ON APPROVED SITE PLAN AND IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE STREET CLOSURE PERMIT REQUIRED PRIOR TO START OF WORK. ANY DEVIATION WILL REQUIRE AN AMENDED BUILDING PERMIT.

  24. PermitAlterations

    Permit 943117 · Expired

    SEAL LATERAL AS PER PHILADELPHIA PLUMBING CODE.

  25. PermitZoning/use

    Permit 885714 · COMPLETED

    FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH ROOF DECK ACCESSED BY A PILOTHOUSE FOR USE AS VACANT INDUSTRIAL USE ( 61.7% GROSS FLOOR AREA OF GROUND FLOOR INDUSTRIAL USE ) AS PERMITTED IN THE IRMX ZONING DISTRICT(USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY) WITH INTERIOR PARKING GARAGE FOR FIVE(5) CARS WITH ONE(1) ACCESSIBLE SPACE AND WITH SEVEN(7) 1A CLASS BICYCLE SPACES IN AN ACCESSIBLE ROUTE AT FIRST FLOOR IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING ( 16 DWELLING UNITS) FROM SECOND FLOOR THROUGH FIFTH FLOORS (SIZE AND LOCATION AS SHOWN ON THE APPLICATION)

  26. PermitZoning/use

    Permit 869808 · COMPLETED

    FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH A PILOT HOUSE ABOVE(NO ROOF DECK) FOR USE AS VACANT COMMERCIAL AS PERMITTED IN THE DISTRICT(USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY) FOR EIGHTEEN(18) DWELLING UNITS ON SECOND THRU FIFTH FLOORS, WITH INTERIOR ACCESSORY PARKING FOR FIVE VEHICLES INCLUDING ONE (1) ADA SPACE(ACCESSED BY AN EASEMENT) AND SIX(6)CLASS 1 A BICYCLE SPACES LOCATED ON AN ACCESSIABLE ROUTE.

  27. PermitZoning

    Permit 860774 · COMPLETED

    1)LOT LINE RELOCATION LOT CONSOLIDATION TO CREATE 1 LOT FROM 2 LOTS. 2) CONSTRUCT 5 STORY, MULTIFAMILY RESIDENTIAL BUILDING WITH 1 COMMERCIAL SPACE AND GARAGE HAVING 3 PARKING SPACES. 3) WITH RELATED BUILDING AND SITE IMPROVEMENTS. 4) ALL PER SUBMITTED PLANS PREPARED BY COSCIA MOOS ARCHITECTS DATED 12/21/17

  28. PermitZoning

    Permit 845371 · COMPLETED

    1)LOT LINE RELOCATION LOT CONSOLIDATION TO CREATE 1 LOT FROM 2 LOTS. 2) CONSTRUCT 5 STORY, MULTIFAMILY RESIDENTIAL BUILDING WITH 1 COMMERCIAL SPACE AND GARAGE HAVING 3 PARKING SPACES. 3) WITH RELATED BUILDING AND SITE IMPROVEMENTS. 4) ALL PER SUBMITTED PLANS PREPARED BY COSCIA MOOS ARCHITECTS DATED 12/21/17

  29. AppealZoning board appeal

    Appeal 29840 · OPEN · Granted

    Related permit 748062 · PERMIT FOR THE RELOCATION OF LOT LINES TO CREAT FOUR (4)NEW LOTS(A,B,C AND 410-26 MEMPHIS ST) FROM THREE EXISTING ZONING LOTS(1421 AND 1423 E COLUMBIA AND 410-26 MEMPHIS ST); ON LOTS A,B,C. FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH A R

  30. InvestigationEP_ELEC

    Case 542402 · PASSED

    The cited inspection visit was marked passed.

  31. PermitAdministrative

    Permit 706065 · COMPLETED

    TCO FOR REMAINING NINE(9)UNITS.

  32. ViolationPENALTY- NO ELEC PERM INFO

    Case 542402 · Violation 3995963 · Code A-901.13/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  33. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 542402 · Violation 3995961 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  34. ViolationPERME- REQUIRED TO CORR VIOL

    Case 542402 · Violation 3995962 · Code A-501.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  35. InvestigationEP_ELEC

    Case 542402 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  36. PermitAdministrative

    Permit 700852 · COMPLETED

    TCO FOR UNITS 101 THRU 111,113 AND 117.

  37. InvestigationBP_BLDG

    Case 528498 · PASSED

    The cited inspection visit was marked passed.

  38. PermitAdministrative

    Permit 695182 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR THE 1ST FLOOR MAIN ENTRY LOBBY,ALSO UNITS 112,201,212,UNITS 301 THRU 312 AND UNITS 401 THRU 412 TOTALING 37 UNITS.

  39. ViolationWORKMANLIKE- BUILDING CODE

    Case 528498 · Violation 3903703 · Code A-104.1/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  40. InvestigationBP_BLDG

    Case 528498 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  41. InvestigationPP_PLUMB

    Case 505832 · CLOSED

    City marked the record closed; open the case for the closing reason.

  42. PermitAdministrative

    Permit 646247 · COMPLETED

    ADMINISTRATIVE PERMIT TO AMEND THE ORIGINAL DEMOLITION PERMIT #592027. TO DOCUMENT THE DEMOLITION OF THE BUILDING ON PREMISES A (1425 E. COLUMBIA), B (1427 E COLUMBIA), C (1429 E COLUMBIA), D (1431 E COLUMBIA), & E (1433 E COLUMBIA). THE PORTION OF THE ORIGINAL BUILDING SITUATED ON PREMISES H (1421 E COLUMBIA) & PREMISES G (1423 E COLUMBIA) TO REMAIM IN PLACE. SEPARATE ZONING AND DEMOLITION PERMITS WILL BE REQUIRED FOR THE REMAINING STRUCTURE ON SITE.

  43. PermitPlumbing

    Permit 611255 · COMPLETED

    INTERIOR PLUMBING CONSTRUCTION IN AN EXISTING (5)STORY BUILDING FOR USE AS A MULTI-FAMILY DWELLING (57 UNITS) INCLUDING EXTERIOR PLUMBING TO THE CURB - NOTE: SEWER/WATER CONNECTIONS TO THE CITY MAINS IN THE STREET, IF REQUIRED, REQUIRE SEPARATE PERMIT(S) - THE INSTALLATION WILL COMPLY WITH THE APPROVED PLANS AND THE PHILADELPHIA PLUMBING CODE 2004 - NOTE: "FLAT OFFSETS" MUST COMPLY WITH SECTION P-117 AND STACKS MUST REMAIN FULL SIZE PER SECTION P-1103.2 OF THE PHILADELPHIA PLUMBING CODE 2004

  44. ViolationPENALTY- NO PLUMB PERM INFO

    Case 505832 · Violation 3735361 · Code A-901.13/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  45. ViolationPERMP- INST SANITARY PIPE SYS

    Case 505832 · Violation 3735360 · Code A-301.1/56 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  46. PermitElectrical

    Permit 625387 · COMPLETED

    3000AMP SERVICE & WIRING THROUGHOUT LIGHTS, RECEPTACLE AS PER NEC 2008 & INSTALL FIRE ALARM AS PER NFPA 72

  47. PermitMechanical

    Permit 629545 · COMPLETED

    FOR THE INSTALLATION OF FIFTY-SEVEN (57) VRV HEAT PUMPS THROUGHOUT DWELLING UNITS AND ALL ASSOCIATED DUCTWORK AS SHOWN IN APPROVED PLANS. ALL APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFCATURER'S SPECIFICATIONS.

  48. PermitSuppression

    Permit 589099 · COMPLETED

    INSTALL FIRE SPRINKLER SYSTEM, SUPPLY LINES, STANDPIPES, PUMP AND ALL INCIDENTALS FOR COMMERCIAL SPACE. FIRE SERVICE 6" CODE/DESIGN PROFESSIONAL: BARRY H. STRITTMATTER, PE.

  49. PermitMajor alteration

    Permit 586890 · COMPLETED

    ALTERATIONS TO BE DONE THROUGHOUT AN EXISTING FIVE STORY BUILDING FOR USE AS A MULTI FAMILY DWELLING (57 DWELLING UNITS) WITH ACCESSORY PARKING. REVIEW COMPLETED UNDER CHAPTER 34- COMPLIANCE ALTERNATIVE METHOD OF THE 2009 IBC. ALTERATIONS TO INCLUDE THE INFILL OF WALLS, ERECTION OF WALLS, PROVIDE ACCESSIBLITY AND STRUCTURAL IMPROVEMENTS THROUGHOUT.STRUCTURE TO BE FULLY SPRINKLERED. STRUCTURE CONTAINS TWO TYPE A DWELLING UNITS WITH ALL OTHER UNITS CONFORMING TO TYPE B DWELLING UNIT CONFIGURATIONS WITH AN ACCESSIBLE ROUTE TO EACH UNIT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  50. PermitZoning/use

    Permit 592029 · COMPLETED

    COMPLETE DEMOLTION OF 1 STORY WAREHOUSE. 2 STORY INSIDE

  51. PermitDemolition

    Permit 592027 · COMPLETED

    COMPLETE DEMOLITION FOR 1 STORY WAREHOUSE

  52. PermitUse

    Permit 514607 · COMPLETED

    VACANT BUILDING (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY). (SITE PLAN, SEE AP #514595).

  53. PermitUse

    Permit 514595 · COMPLETED

    VACANT BUILDING (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY). (SITE PLAN, SEE AP #514595).

  54. PermitZoning

    Permit 477732 · COMPLETED

    RELOCATION OF LOT LINES TO CREATE EIGHT(8) LOTS (PREMISES A TO H) FROM ONE LOT 1421-37 E COLUMBIA AVE).

  55. PermitAlteration

    Permit 508022 · COMPLETED

    BRICKPOINT EXTERIOR OF BUILDING AS NEEDED, AND REPAIR LOOSE AND BROKEN AREAS OF CONCRETE AND STUCCO.

  56. AppealZoning board appeal

    Appeal 21037 · CLOSED · Granted with conditions

    Related permit 477732 · PERMIT FOR THE RELOCATION OF LOT LINES TO CREATE ONE LOT FROM EIGHT LOTS. INTERIOR RENOVATION OF THE EXISTING STRUCTURE TO INCLUDE FITNESS CENTER (PERSONAL SERVICES) ON A PORTION OF FIRST & SECOND FLOOR AND FIFTY-SEVEN (57) FAMILY DWELLING,

Where this comes from

Methodology & freshness

This report was assembled Jul 28, 2026, 6:20 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)