Property report

1515 Arch St

293,854 sqftCMX5built 1965

Property at a glanceCommercial

Phila Auth For Ind Dev

2026 assessment
$45M OPA value, not a listing price
2027 published assessment
$45M Future roll, not the current tax bill
Neighborhood area
Center City West Approximate · based on ZIP 19102
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $44,915,600. It is not yet the billed-year tax basis.

$0$25M$50M$45M201220152018202120242027
Property assessmentAssessmentL&I violationPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record82 events · exact dates, newest first
  1. InspectionL&I investigation
  2. L&I violationFACADES
  3. InspectionL&I investigation
  4. L&I violationFACADES
  5. InspectionL&I investigation
  6. CertificationFire Alarm Certification
  7. PermitAddition and/or Alteration
  8. PermitAddition and/or Alteration
  9. InspectionL&I investigation
  10. InspectionL&I investigation
  11. PermitAddition and/or Alteration
  12. PermitAddition and/or Alteration
  13. PermitAddition and/or Alterations
  14. PermitAddition and/or Alteration
  15. CertificationEmergency and Standby Power Systems Certification
  16. CertificationEmergency and Standby Power Systems Certification
  17. CertificationFire Alarm Certification
  18. CertificationFire Alarm Certification
  19. InspectionL&I investigation
  20. PermitAddition and/or Alteration
  21. PermitAddition and/or Alterations
  22. PermitAddition and/or Alteration
  23. PermitAddition and/or Alteration
  24. PermitAddition and/or Alteration
  25. PermitAddition and/or Alteration
  26. PermitAddition and/or Alteration
  27. PermitAddition and/or Alteration
  28. PermitAddition and/or Alterations
  29. PermitAddition and/or Alteration
  30. CertificationEmergency and Standby Power Systems Certification
  31. CertificationEmergency and Standby Power Systems Certification
  32. PermitAddition and/or Alteration
  33. CertificationFire Alarm Certification
  34. CertificationFire Alarm Certification
  35. PermitAddition and/or Alterations
  36. PermitAddition and/or Alteration
  37. CertificationSprinkler Certification
  38. InspectionL&I investigation
  39. L&I violationNEW ELECTRICAL WIRING
  40. InspectionL&I investigation
  41. CertificationEmergency and Standby Power Systems Certification
  42. CertificationSprinkler Certification
  43. CertificationFire Alarm Certification
  44. PermitAddition and/or Alteration
  45. CertificationFacade Report
  46. PermitAddition and/or Alterations
  47. PermitAlterations
  48. PermitAddition and/or Alterations
  49. PermitAddition and/or Alteration
  50. L&I violationUNSAFE STRUCTURE
  51. L&I violationFAILURE TO SUBMIT FACADE REPT
  52. InspectionCSUINITIAL
  53. InspectionCSUINITIAL
  54. InspectionCSUINITIAL
  55. InspectionCI INSP
  56. InspectionCSUINITIAL
  57. L&I violationEXIT DOORS SELF CLOSING/LATCHI
  58. L&I violationMEANS OF EGRESS EXTERIOR
  59. L&I violationEXTINGUISHER MOUNTED
  60. L&I violationLO SIGN
  61. L&I violationOUTSIDE STORAGE/PROPERTY LINE
  62. L&I violationEMERGENCY LIGHTING TESTED
  63. L&I violationEXIT SIGN ILLUMINATION
  64. L&I violationPULL STATION SIGNS
  65. L&I violationFIRE ALARM TESTED/CERTIFIED
  66. InspectionCI INSP
  67. PermitElectrical
  68. PermitMajor alteration
  69. PermitElectrical
  70. PermitMajor alteration
  71. InspectionCSUINITIAL
  72. PermitSuppression
  73. PermitElectrical
  74. L&I violationUNSAFE STRUCTURE
  75. L&I violationARCHITECT/ENGINEER SERVICES
  76. L&I violationEXTERIOR STRUCT UNSAFE COND 7
  77. InspectionCSUINITIAL
  78. PermitElectrical
  79. PermitMajor alteration
  80. InspectionBP_BLDG
  81. PermitElectrical
  82. PermitPlumbing

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $44,915,600. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 772059100
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

2 open violations

What it is
Commercial Off Bld N/Pkg N/Com Mason
Owner
Phila Auth For Ind Dev
$ / sq ft
$153 above the $151 median for 7,668 commercial parcels citywide
Corridor
Parkway/Logan Circle city commercial corridor
Interior area
293,854 sqft
Lot size
34,913 sqft
Built
1965
Zoning
CMX5

Recorded owner

Who's behind it

Phila Auth For Ind Dev · corporate / LLC owner

• Owns 12 properties across Philadelphia under this name, assessed at $63M combined
• Tax bills mail to 1500 Market St, Philadelphia PA, 19102

Block context

1500 block of Arch St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1513 Arch St  ·  1503-11 Arch St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 24, 2026.

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 82 dated rows
  1. InvestigationL&I investigation

    Case CF-2026-050957 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  2. ViolationFACADES

    Case CF-2026-060689 · Violation VI-2026-036946 · Code PM15-315.2 · OPEN

  3. InvestigationL&I investigation

    Case CF-2026-060689 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  4. ViolationFACADES

    Case CF-2026-050957 · Violation VI-2026-030861 · Code PM15-315.2 · OPEN

  5. InvestigationL&I investigation

    Case CF-2026-050957 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  6. CertificationFire Alarm Certification

    Certification BC-2026-011239 · Certified

    Expires 2027-04-20

  7. PermitAddition and/or Alteration

    Permit EP-2026-001461 · Issued

    Furnish and install new disconnect switches and mounting hardware with new wires. We will install (2) new chargers. From existing MDP & EV Panel . ALL WOR

  8. PermitAddition and/or Alteration

    Permit EP-2025-006673 · Completed

    Disconnect and replace existing lighting fixtures and switches. Furnish and install a new motorized shades system. Provide power to new desk. Test and label new devices. The panels are existing. Installation shall comply with 2017 NEC.

  9. InvestigationL&I investigation

    Case CF-2023-127433 · PASSED

    The cited inspection visit was marked passed.

  10. InvestigationL&I investigation

    Case CF-2023-127433 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  11. PermitAddition and/or Alteration

    Permit CP-2025-001870 · Completed

    FOR LEVEL II ALTERATIONS TO 18TH FLOOR IN AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. ***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************

  12. PermitAddition and/or Alteration

    Permit EP-2025-003090 · Completed

    INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLES OUTLETS. INSTALL EMERGENCY LIGHTING AND SMOKE DETECTOR ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.

  13. PermitAddition and/or Alterations

    Permit FP-2025-000817 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (32) SPRINKLER HEADS, PER NFPA 13

  14. PermitAddition and/or Alteration

    Permit CP-2025-001498 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 14TH FLOOR LEVEL OF AN EXISTNG STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ** BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**

  15. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-008858 · Certified

    Expires 2026-03-09

  16. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-008860 · Certified

    Expires 2026-03-09

  17. CertificationFire Alarm Certification

    Certification BC-2025-003964 · Certified

    Expires 2026-02-04

  18. CertificationFire Alarm Certification

    Certification BC-2025-003962 · Certified

    Expires 2026-02-04

  19. InvestigationL&I investigation

    Case 658470 · PASSED

    The cited inspection visit was marked passed.

  20. PermitAddition and/or Alteration

    Permit EP-2024-011617 · Completed

    Furnish and install new lighting fixtures, switches and new receptacles. Relocate fire alarm devices .Test and label all the new devices. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-202017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  21. PermitAddition and/or Alterations

    Permit FP-2024-002427 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (33) SPRINKLER HEADS AS PER NFPA 13

  22. PermitAddition and/or Alteration

    Permit CP-2024-006211 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING BUILDING FOR USE AS A BUSINESS OFFICE ON THE 11TH FLOOR OF AN EXISTING BUILDING, ALTERATIONS TO INCLUDE THE ERECTION OF NON-BEARING PARTITION WALLS, PROVIDE FINISHES, AND FURNISHINGS THROUGHOUT TO CREATE ADDITIONAL OFFICES. NO CHANGE IN OCCUPANCY CLASSIFICATION. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  23. PermitAddition and/or Alteration

    Permit EP-2024-010199 · Completed

    Electrical Permit for combo CP-2024-005230

  24. PermitAddition and/or Alteration

    Permit CP-2024-005230 · Expired

    FOR SITEWORK AND INSTALLATION OF ELECTRICAL VEHICLE CHARGING STATIONS.

  25. PermitAddition and/or Alteration

    Permit EP-2024-009272 · Completed

    Furnish and install new lighting fixtures, switches and new receptacles. **NO FIRE ALARM ON THIS PERMIT**

  26. PermitAddition and/or Alteration

    Permit EP-2024-008105 · Completed

    Provide and install new lighting fixtures and controls. Provide receptacles, specified wiring devices, associated cover plates, and branch circuit wiring.

  27. PermitAddition and/or Alteration

    Permit CP-2024-004161 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS AND PROVIDE FINISHES/FURNISHINGS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  28. PermitAddition and/or Alterations

    Permit FP-2024-001707 · Expired

    ALTERATIONS TO EXISTING SPRINKLER SYSTEM FOR EXTENSION OF DRY SYSTEM TO PROVIDE COVERAGE UNDER GROUND FLOOR LEVEL CAR PORT IN ACCORDANCE WITH NFPA 13 AND AS PER APPROVED PLANS.

  29. PermitAddition and/or Alteration

    Permit EP-2024-005126 · Completed

    Furnish and install new lighting fixtures, switches, and new receptacles.

  30. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-016443 · Certified

    Expires 2025-06-01

  31. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-016444 · Certified

    Expires 2025-06-01

  32. PermitAddition and/or Alteration

    Permit CP-2024-001359 · Completed

    FOR LEVEL 2 ALTERATION TO THE 17TH FLOOR OF AN EXISTING HIGHRISE STRUCTURE AS PER PLANS. NO CHANGE IN OCCUPANCY CLASSIFICATION. SEPARATE PERMITS ARE REQUIRED FOR ANY MECHANICAL ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  33. CertificationFire Alarm Certification

    Certification BC-2024-005813 · Certified

    Expires 2025-03-02

  34. CertificationFire Alarm Certification

    Certification BC-2024-005805 · Certified

    Expires 2025-03-02

  35. PermitAddition and/or Alterations

    Permit FP-2024-000338 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (10) sprinkler heads as per NFPA 13

  36. PermitAddition and/or Alteration

    Permit CP-2024-000675 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING BUILDING FOR USE AS A BUSINESS OFFICE ON THE 15TH FLOOR OF AN EXISTING BUILDING, ALTERATIONS TO INCLUDE THE ERECTION OF NON-BEARING PARTITION WALLS, PROVIDE FINISHES, AND FURNISHINGS THROUGHOUT TO CREATE ADDITIONAL OFFICES. NO CHANGE IN OCCUPANCY CLASSIFICATION. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  37. CertificationSprinkler Certification

    Certification BC-2024-006376 · Certified

    Expires 2025-02-12

  38. InvestigationL&I investigation

    Case CF-2023-127433 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  39. ViolationNEW ELECTRICAL WIRING

    Case CF-2023-127433 · Violation VI-2023-097225 · Code A-301.1/50 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  40. InvestigationL&I investigation

    Case CF-2023-127433 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  41. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2023-020879 · Certified

    Expires 2024-03-04

  42. CertificationSprinkler Certification

    Certification BC-2022-018832 · Certified

    Expires 2023-09-30

  43. CertificationFire Alarm Certification

    Certification BC-2023-004278 · Certified

    Expires 2023-05-24

  44. PermitAddition and/or Alteration

    Permit EP-2021-004022 · Completed

    Level II Interior alterations (no change to occupancy) for renovations to ground floor office space in an existing high-rise building as per approved plans. Running category 6 plenum cable data cable to office as per 2017 nec

  45. CertificationFacade Report

    Certification BC-2021-002040 · Safe with Repair

    Expires 2026-05-11

  46. PermitAddition and/or Alterations

    Permit MP-2021-001865 · Completed

    Alteration to the existing HVAC system within the office space on ground floor to accommodate new floor layout as per approved plans.

  47. PermitAlterations

    Permit PP-2021-004927 · Completed

    To install 5 new fixtures, running new sanitary & water lines to the mains. One water closet, one lavatory, one electric water cooler, and two tubs.

  48. PermitAddition and/or Alterations

    Permit FP-2021-000809 · Completed

    We will be relocating (28) sprinklers at DHS, Child Intake 1st floor. See CP-01650

  49. PermitAddition and/or Alteration

    Permit CP-2021-001650 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO GROUND FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  50. ViolationUNSAFE STRUCTURE

    Case 721919 · Violation 5293569 · Code PM15-108.1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  51. ViolationFAILURE TO SUBMIT FACADE REPT

    Case 721919 · Violation 5293568 · Code PM-304.10/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  52. InvestigationCSUINITIAL

    Case 721919 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  53. InvestigationCSUINITIAL

    Case 586244 · PASSED

    The cited inspection visit was marked passed.

  54. InvestigationCSUINITIAL

    Case 586244 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  55. InvestigationCI INSP

    Case 658470 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  56. InvestigationCSUINITIAL

    Case 586244 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  57. ViolationEXIT DOORS SELF CLOSING/LATCHI

    Case 658470 · Violation 211953464 · Code FC-13-100825 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  58. ViolationMEANS OF EGRESS EXTERIOR

    Case 658470 · Violation 211953465 · Code FC-13-100331 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  59. ViolationEXTINGUISHER MOUNTED

    Case 658470 · Violation 211953466 · Code FC-13-906.7 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  60. ViolationLO SIGN

    Case 658470 · Violation 211953467 · Code FC-13-1004.2 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  61. ViolationOUTSIDE STORAGE/PROPERTY LINE

    Case 658470 · Violation 211953459 · Code FC-13-315.3 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  62. ViolationEMERGENCY LIGHTING TESTED

    Case 658470 · Violation 211953461 · Code FC-13-604.1 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  63. ViolationEXIT SIGN ILLUMINATION

    Case 658470 · Violation 211953460 · Code FC-13-1007.2 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  64. ViolationPULL STATION SIGNS

    Case 658470 · Violation 211953462 · Code FC-13-907.51 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  65. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 658470 · Violation 211953463 · Code FC-13-915.1 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  66. InvestigationCI INSP

    Case 658470 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  67. PermitElectrical

    Permit 894107 · COMPLETED

    REMOVE EXISTING MODULAR FURNITURE DESK POWER AND WHIPS,RELOCATE POWER TO 8 NEW DESK LOCATIONS WITH CAT6E PLENUM RATED CABLE WITH THE LONGEST RUN OF 10FT AS PER 2008 NEC (CC DISTRICT)

  68. PermitMajor alteration

    Permit 881582 · EXPIRED

    FOR INTERIOR LEVEL 2 ALTERATIONS INCLUDING DEMOLITION OF EXISTING INTERIOR, NON-LOAD BEARING PARTITIONS AND FINISHES, NEW PARTITIONS, FLOOR./WALL FINISHES AND DOORS AS PER PLANS. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  69. PermitElectrical

    Permit 865203 · COMPLETED

    RELOCATE LIGHTING OUTLETS SWITCHES, 6 VOICE DATA AS PER 2008 NEC CODE.

  70. PermitMajor alteration

    Permit 851580 · COMPLETED

    FOR INTERIOR ALTERATIONS TO AN EXISTING SPACE TO INCLUDE NEW INTERIOR PARTITION WALLS AND WALL/FLOOR/CEILING FINISHING. (IEBC 2009, WORK-AREA METHOD, LVL II ALTERATIONS) **SEPARATE PERMITS REQ'D FOR ELECTRICAL, PLUMBING, AND MECHANICAL ALTERATIONS.**

  71. InvestigationCSUINITIAL

    Case 586244 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  72. PermitSuppression

    Permit 830547 · COMPLETED

    FOR THE EXTENSION OF AN EXISTING NFPA 13 SYSTEM IN THE LOADING DOCK AREA OF AN EXISTING PARKING GARAGE. NFPA 13 SYSTEM SERVICED BY AN EXISTING SIX INCH FIRE SERVICE LINE WITH AN EXISTING BACK FLOW PREVENTER ASSEMBLY AND EXISTING FIRE PUMP. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13 STANDARD.

  73. PermitElectrical

    Permit 809497 · COMPLETED

    ADD POWER POLE FOR CONNECTION OF MODULAR FURNITURE, ADD 3 - 120VOLT CIRCUITS FOR MODULAR FURNITUE, ADD 9 CAT6E PLENUM DATA JACKS LONGEST RUN 110 FT FOR USE IN MODULAR FURNITURE AS PER 2008 NEC (CC DISTRICT)

  74. ViolationUNSAFE STRUCTURE

    Case 586244 · Violation 4913179 · Code PM15-108.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  75. ViolationARCHITECT/ENGINEER SERVICES

    Case 586244 · Violation 4913178 · Code A-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  76. ViolationEXTERIOR STRUCT UNSAFE COND 7

    Case 586244 · Violation 4913180 · Code PM15-304.1G · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  77. InvestigationCSUINITIAL

    Case 586244 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  78. PermitElectrical

    Permit 763979 · COMPLETED

    INSTALL NEW RECEPTACLES, SWITCHES, TELEPHONE LINES, RE-WORK CIRCUITS, RELOCATE SOUND SPEAKER,RELOCATE LIGHT FIXTURES AS PER 2008 NEC (CC DISTRICT) RELOCATE ONE HORN STROBE AS PER NFPA 72

  79. PermitMajor alteration

    Permit 747885 · COMPLETED

    FOR ALTERATIONS IN AN EXISTING STRUCTURE TO INCLUDE NEW INTERIOR PARTITION WALLS AND INTERIOR FLOOR/WALL/CEILING FINISHING. **SEPARATE PERMITS TO BE REQUIRED FOR ANY ELECTRICAL AND MECHANICAL ALTERATIONS.**

  80. InvestigationBP_BLDG

    Case 433140 · PASSED

    The cited inspection visit was marked passed.

  81. PermitElectrical

    Permit 471834 · COMPLETED

    57-1 FOR 1 LGT FIXTURE REPLACEMENT, 83-LAMP & BALLAST REPLACEMENT, INSLL 2-PHOTO CELL CONTROL & 1-WALL SWITCH OCCUPANCY SENSOR AS PER NEC 2008 (MULTI STORY OFFICE BLDG

  82. PermitPlumbing

    Permit 428990 · COMPLETED

    REPLACE WC AND URINAL WITH NEW CHINA A FLUSH VALVES. REPLACE TANK TOILETS WITH NEW(COMMERCIAL OFFICE BLDG) - NOTE: CONTRACTOR CHANGE EFFECTIVE 02/28/2014

Where this comes from

Methodology & freshness

This report was assembled Jul 25, 2026, 8:29 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)