Industrial property report

161-73 Cecil B Moore Ave

1 story32,466 sqftICMXbuilt 1925

Property at a glanceIndustrial

161-73 Cecil B Moore LP

2026 assessment
$2.4M OPA value, not a listing price
2027 published assessment
$2.9M Future roll, not the current tax bill
Neighborhood area
Olde Kensington · North Philadelphia Approximate · based on ZIP 19122
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $2,921,900. It is not yet the billed-year tax basis.

$0$2.5M$5.0M$2.9M2006201020142018202220262027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record258 events · exact dates, newest first
  1. CertificationSpecial Hazards Certification
  2. CertificationFire Alarm Certification
  3. CertificationSprinkler Certification
  4. LicenseSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Preparing and Serving business license marked inactive
  5. PermitAddition and/or Alteration
  6. CertificationFire Alarm Certification
  7. CertificationFire Alarm Certification
  8. LicenseSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive
  9. LicenseSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued
  10. LicenseALAMODAK INC: Handbill Distribution L&I license filing marked expired
  11. LicenseAlamodak Inc (Alamodak): Sidewalk Cafe (Temporary) L&I license filing marked inactive
  12. PermitAddition and/or Alteration
  13. PermitChange of Use
  14. InspectionL&I investigation
  15. InspectionL&I investigation
  16. InspectionL&I investigation
  17. InspectionL&I investigation
  18. InspectionL&I investigation
  19. LicenseAlamodak Inc (Alamodak): Sidewalk Cafe (Temporary) L&I license filing initially issued
  20. CertificationSprinkler Certification
  21. CertificationFire Alarm Certification
  22. CertificationFire Alarm Certification
  23. PermitChange of Use
  24. LicenseSWEET GRACE DISTILLING CO LLC (FEDERAL DISTILLING): Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive
  25. LicenseSWEET GRACE DISTILLING CO LLC (FEDERAL DISTILLING): Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued
  26. PermitAddition and/or Alteration
  27. PermitExterior Window and Door Replacement
  28. InspectionL&I investigation
  29. InspectionL&I investigation
  30. InspectionL&I investigation
  31. PermitAddition and/or Alterations
  32. PermitAddition and/or Alteration
  33. PermitAddition and/or Alteration
  34. LicenseFOUR HUMOURS WHISKEY: Food Preparing and Serving (30+ SEATS) business license marked inactive
  35. PermitAddition and/or Alteration
  36. PermitRough-In
  37. L&I violationLIQUID PETROLEUM GASES
  38. L&I violationFIRE SYSTEMS MAINTAINED
  39. InspectionL&I investigation
  40. L&I violationEXTENSION CORDS
  41. L&I violationFLAMMABLE LIQUID STORAGE
  42. L&I violationNEW USE
  43. PermitChange of Use
  44. PermitShelter/Platform
  45. PermitAmend for conversion
  46. PermitAdministrative
  47. PermitUse
  48. LicenseFOUR HUMOURS WHISKEY: Food Preparing and Serving (30+ SEATS) business license initially issued
  49. PermitAdministrative
  50. InspectionPRECOURT (likely: pre-court compliance inspection)
  51. InspectionPRECOURT (likely: pre-court compliance inspection)
  52. InspectionPRECOURT (likely: pre-court compliance inspection)
  53. InspectionPRECOURT (likely: pre-court compliance inspection)
  54. PermitPlumbing
  55. PermitNew Construction
  56. PermitMechanical
  57. PermitAddition and/or Alteration
  58. InspectionBP_BLDG
  59. InspectionBP_BLDG
  60. InspectionBP_BLDG
  61. InspectionBP_BLDG
  62. InspectionBP_BLDG
  63. PermitAddition and/or Alteration
  64. InspectionBP_BLDG
  65. PermitAlterations
  66. InspectionBP_BLDG
  67. PermitNew Construction
  68. PermitPlumbing
  69. PermitPlumbing
  70. InspectionCEASE INSP (likely: cease-operations compliance inspection)
  71. InspectionPRECOURT (likely: pre-court compliance inspection)
  72. InspectionPRECOURT (likely: pre-court compliance inspection)
  73. PermitMechanical
  74. PermitUse
  75. PermitMechanical
  76. PermitAddition and/or Alteration
  77. PermitElectrical
  78. PermitSuppression
  79. InspectionPRECOURT (likely: pre-court compliance inspection)
  80. InspectionPRECOURT (likely: pre-court compliance inspection)
  81. InspectionBP_BLDG
  82. InspectionBP_BLDG
  83. InspectionBP_BLDG
  84. InspectionBP_BLDG
  85. InspectionBP_BLDG
  86. PermitNew Construction
  87. InspectionBP_BLDG
  88. InspectionBP_BLDG
  89. PermitElectrical
  90. PermitPlumbing
  91. PermitElectrical
  92. PermitPlumbing
  93. PermitMechanical
  94. PermitElectrical
  95. InspectionPRECOURT (likely: pre-court compliance inspection)
  96. InspectionPRECOURT (likely: pre-court compliance inspection)
  97. PermitUse
  98. PermitMajor alteration
  99. L&I violationPERMB- INSTALL HVAC SYS
  100. L&I violationPERMP- INST FIXTURE W/O PERMIT
  101. L&I violationPERMP- ALTER/REPAIR/REPL PLUMB
  102. L&I violationPERME- INST COMMUN WIRE/EQUIP
  103. L&I violationPERME- INST COMMUN WIRE/EQUIP
  104. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  105. L&I violationPERME- INST COMMUN WIRE/EQUIP
  106. L&I violationPERMP- INST NEW PLUMBING
  107. L&I violationPENALTY- NO BLDG PERM INFO
  108. L&I violationPERMB- INSTALL SECURITY GATE
  109. L&I violationPERMP- INST NEW PLUMBING
  110. L&I violationPENALTY- NO BLDG PERM INFO
  111. L&I violationPENALTY- NO ELEC PERM INFO
  112. L&I violationPENALTY- NO PLUMB PERM INFO
  113. L&I violationPERMB- INSTALL HVAC SYS
  114. L&I violationPERMB- INSTALL INT PARTITIONS
  115. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  116. L&I violationPERMB- INSTALL SECURITY GATE
  117. L&I violationPENALTY- NO BLDG PERM INFO
  118. L&I violationARCHITECT/ENGINEER SERVICES
  119. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  120. L&I violationPENALTY- NO ELEC PERM INFO
  121. InspectionBP_BLDG
  122. InspectionBP_BLDG
  123. InspectionBP_BLDG
  124. InspectionBP_BLDG
  125. InspectionBP_BLDG
  126. InspectionBP_BLDG
  127. InspectionPRECOURT (likely: pre-court compliance inspection)
  128. InspectionBP_BLDG
  129. InspectionPRECOURT (likely: pre-court compliance inspection)
  130. InspectionPRECOURT (likely: pre-court compliance inspection)
  131. AppealZoning board appeal
  132. PermitMajor alteration
  133. InspectionPRECOURT (likely: pre-court compliance inspection)
  134. InspectionPRECOURT (likely: pre-court compliance inspection)
  135. InspectionPRECOURT (likely: pre-court compliance inspection)
  136. PermitMajor alteration
  137. PermitUse
  138. PermitMajor alteration
  139. PermitUse
  140. PermitUse
  141. PermitSuppression
  142. LicenseALAMODAK INC **: Food Preparing and Serving (30+ SEATS) business license initially issued
  143. PermitUse
  144. InspectionCI INSP
  145. InspectionCI INSP
  146. InspectionCI INSP
  147. InspectionCI INSP
  148. LicenseALAMODAK INC: Food Preparing and Serving business license marked inactive
  149. PermitUse
  150. PermitUse
  151. L&I violationPERM Z- NEW USE
  152. L&I violationCO- NEW USE OCCUPIED PRE-CO
  153. L&I violationVIOL C&I MESSAGE
  154. L&I violationGENERAL REQ.- CITE CODE SECTIO
  155. L&I violationFIRE DOORS CLOSE/LATCH
  156. L&I violationFIRE SUPPRESSION CERTIFICATION
  157. L&I violationVENTILATION - BATHROOMS
  158. L&I violationFIRE RESISTANCE RATING
  159. L&I violationVIOL C&I MESSAGE
  160. L&I violationFIRE ALARM/DETECTION SYSTEMS
  161. L&I violationSUPPRESSION SYSTEM REQ'D
  162. L&I violationFIRE ALARM TESTED/CERTIFIED
  163. L&I violationCONTAINER CONTENTS
  164. L&I violationNFPA 704 SIGNS
  165. L&I violationVIOL C&I MESSAGE
  166. L&I violationHAZMAT LICENSE REQUIRED
  167. L&I violationHOOD CLEANING
  168. L&I violationFIRE EXTINGUISHERS TAGGED
  169. L&I violationCOOKING EQUIPMENT POSITIONING
  170. L&I violationVIOL C&I MESSAGE
  171. L&I violationWET CHEMICAL SYSTEM TEST
  172. InspectionCI INSP
  173. InspectionCI INSP
  174. InspectionCI INSP
  175. InspectionCI INSP
  176. PermitSuppression
  177. PermitElectrical
  178. PermitUse
  179. PermitAlteration
  180. PermitAdministrative
  181. PermitUse
  182. LicenseALAMODAK INC: Handbill Distribution L&I license filing initially issued
  183. LicenseALAMODAK INC: Food Preparing and Serving business license initially issued
  184. PermitSuppression
  185. AppealZoning board appeal
  186. PermitPlumbing
  187. PermitElectrical
  188. PermitMechanical
  189. PermitMajor alteration
  190. LicenseSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Preparing and Serving business license initially issued
  191. PermitUse
  192. AppealZoning board appeal
  193. PermitUse
  194. AppealZoning board appeal
  195. LicenseSWEET GRACE DISTILLING CO LLC (FEDERAL DISTILLING): Food Manufacturer / Wholesaler business license initially issued
  196. PermitZoning/use
  197. PermitMajor alteration
  198. PermitUse
  199. AppealZoning board appeal
  200. InspectionPRECOURT (likely: pre-court compliance inspection)
  201. PermitPlumbing
  202. PermitElectrical
  203. PermitMechanical
  204. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  205. PermitPlumbing
  206. PermitUse
  207. PermitMajor alteration
  208. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  209. InspectionCEASE INSP (likely: cease-operations compliance inspection)
  210. L&I violationPERM Z- NEW USE
  211. InspectionCEASE INSP (likely: cease-operations compliance inspection)
  212. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  213. L&I violationPERM - MUST POST
  214. PermitMajor alteration
  215. PermitUse
  216. InspectionCEASE INSP (likely: cease-operations compliance inspection)
  217. InspectionCEASE INSP (likely: cease-operations compliance inspection)
  218. PermitUse
  219. L&I violationCO- BLDG OCCUPIED PRE-CO
  220. InspectionCI INSP
  221. InspectionCEASE INSP (likely: cease-operations compliance inspection)
  222. PermitUse
  223. PermitUse
  224. L&I violationPERM Z- NEW USE
  225. L&I violationCAL PROHIBITED CONDUCT
  226. L&I violationSPECIAL ASSEMBLY OCC LO
  227. InspectionCI INSP
  228. InspectionCI INSP
  229. InspectionPRECOURT (likely: pre-court compliance inspection)
  230. L&I violationLICENSE-VAC COMM BLDG
  231. InspectionCI INSP
  232. InspectionCSUINITIAL
  233. InspectionCSUINITIAL
  234. L&I violationROOF PARTIALLY COLLAPSED
  235. L&I violationFLOOR/CEILING PARTIALLY COLL
  236. InspectionCSUINITIAL
  237. InspectionPRECOURT (likely: pre-court compliance inspection)
  238. InspectionPRECOURT (likely: pre-court compliance inspection)
  239. InspectionPRECOURT (likely: pre-court compliance inspection)
  240. InspectionPRECOURT (likely: pre-court compliance inspection)
  241. L&I violationCOULD NOT ENTER
  242. InspectionCI INSP
  243. InspectionCI INSP
  244. L&I violationFIRE DEPT CONNECT REP DAM CAPS
  245. L&I violationVIOL C&I MESSAGE
  246. L&I violationVACANT PROP STANDARD (likely: vacant-property enforcement standard)
  247. L&I violationLICENSE-VAC COMM BLDG
  248. L&I violationEXT S-WALLS REPAIR CRACKS
  249. L&I violationANNUAL CERT FIRE SUPP
  250. InspectionCI INSP
  251. PermitDemolition
  252. PermitZoning/use
  253. AppealZoning board appeal
  254. InspectionPRECOURT (likely: pre-court compliance inspection)
  255. InspectionCI INSP
  256. InspectionCI INSP
  257. InspectionCI INSP
  258. InspectionCI INSP

Verify the public record

$34,085/year estimated property tax

2026 taxable assessment $2,435,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $2,921,900. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 884589950
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Industrial property

Industrial, recorded in the City's industrial category. The public record and owner trail follow.

What it is
Industrial Ind Loft Masonry
Owner
161-73 Cecil B Moore LP
$ / sq ft
$90 above the $70 median for 3,574 industrial parcels citywide
Interior area
32,466 sqft
Lot size
21,600 sqft
Stories
1
Built
1925
Zoning
ICMX

Recorded owner

Who's behind it

161-73 Cecil B Moore LP · corporate / LLC owner

• Tax bills mail to 161-73 Cecil B Moore Ave, Philadelphia PA, 19122

Block context

100 block of Cecil B Moore Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 155-59 Cecil B Moore Ave  ·  107 Cecil B Moore Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
FOUR HUMOURS WHISKEYInactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Sep 10, 2019 · Terminal license date Nov 8, 2020

ALAMODAK INC **Active

Food Preparing and Serving (30+ SEATS) · Initial issue date Apr 11, 2018 · Filed expiration Apr 10, 2027

ALAMODAK INCInactive

Food Preparing and Serving · Initial issue date Feb 1, 2017 · Terminal license date Apr 1, 2018

SWEET GRACE DISTILLING CO LLC (STATESIDE VODKA)Inactive

Food Preparing and Serving · Initial issue date May 24, 2016 · Terminal license date Jul 22, 2024

SWEET GRACE DISTILLING CO LLC (FEDERAL DISTILLING)Active

Food Manufacturer / Wholesaler · Initial issue date Nov 4, 2015 · Filed expiration Apr 30, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 256 dated rows
  1. CertificationSpecial Hazards Certification

    Certification BC-2026-010617 · Deficient

  2. CertificationFire Alarm Certification

    Certification BC-2026-011383 · Certified

    Expires 2027-03-12

  3. CertificationSprinkler Certification

    Certification BC-2026-011382 · Certified

    Expires 2027-03-12

  4. License terminal eventSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Preparing and Serving business license marked inactive

    License 702864 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  5. PermitAddition and/or Alteration

    Permit CP-2024-002663 · Completed

    FOR THE REPLACEMENT OF ROOF STRUCTURAL BEAM, JOISTS WITH SHEATING AND ROOF COVERING AS PER APPROVED PLANS.

  6. CertificationFire Alarm Certification

    Certification BC-2024-003975 · Certified

    Expires 2024-11-20

  7. CertificationFire Alarm Certification

    Certification BC-2023-021897 · Deficient

  8. License terminal eventSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive

    License 923097 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  9. License issue eventSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued

    License 923097 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  10. License terminal eventALAMODAK INC: Handbill Distribution L&I license filing marked expired

    License 730813 · Expired

    License event. Registration does not prove present operation or storefront occupancy.

  11. License terminal eventAlamodak Inc (Alamodak): Sidewalk Cafe (Temporary) L&I license filing marked inactive

    License 891818 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  12. PermitAddition and/or Alteration

    Permit CP-2022-004063 · Expired

    LEVEL II INTERIOR ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO SUBDIVIDE EXISTING SECOND FLOOR TENANT SPACE INTO TWO NEW BUSINESS SPACES (SPACES 210 & 210A) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  13. PermitChange of Use

    Permit ZP-2022-008486 · Issued

    Office - Business and Professional

  14. InvestigationL&I investigation

    Case 620868 · PASSED

    The cited inspection visit was marked passed.

  15. InvestigationL&I investigation

    Case 620885 · PASSED

    The cited inspection visit was marked passed.

  16. InvestigationL&I investigation

    Case 620885 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  17. InvestigationL&I investigation

    Case 620868 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  18. InvestigationL&I investigation

    Case CF-2020-060072 · PASSED

    The cited inspection visit was marked passed.

  19. License issue eventAlamodak Inc (Alamodak): Sidewalk Cafe (Temporary) L&I license filing initially issued

    License 891818 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  20. CertificationSprinkler Certification

    Certification BC-2022-007749 · Certified

    Expires 2023-04-06

  21. CertificationFire Alarm Certification

    Certification BC-2022-004889 · Certified

    Expires 2023-04-05

  22. CertificationFire Alarm Certification

    Certification BC-2022-004597 · Certified

    Expires 2023-04-05

  23. PermitChange of Use

    Permit ZP-2022-002167 · Issued

    Office - Business and Professional

  24. License terminal eventSWEET GRACE DISTILLING CO LLC (FEDERAL DISTILLING): Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive

    License 877852 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  25. License issue eventSWEET GRACE DISTILLING CO LLC (FEDERAL DISTILLING): Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued

    License 877852 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  26. PermitAddition and/or Alteration

    Permit CP-2021-001073 · Completed

    FOR THE INSTALLATION OF SPIRAL STAIRCASE PER APPROVED PLANS.

  27. PermitExterior Window and Door Replacement

    Permit GM-2021-008613 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  28. InvestigationL&I investigation

    Case CF-2021-032674 · PASSED

    The cited inspection visit was marked passed.

  29. InvestigationL&I investigation

    Case CF-2021-032674 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  30. PermitAddition and/or Alterations

    Permit MP-2020-006373 · Completed

    For the installation of two (2) mechanical appliances (glycol chiller and steam boiler) w/associated piping within an existing Group H-2/H-3 tenant (vodka distillery), as per plans; separate permit required for associated electrical work; see CP-2020-004551 for building permit.

  31. PermitAddition and/or Alteration

    Permit EP-2020-011504 · Completed

    Supply and install wire and conduit for a new boiler and a new chiller. Supply and install wire and conduit for garage door openers. ALL WORK TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  32. PermitAddition and/or Alteration

    Permit CP-2020-004551 · Completed

    FOR PARTIAL RENOVATION OF AN EXISTING DISTILLERY FACILITY TO ENLARGE AN EXISTING BOILER ROOM AND TO EXPAND THE FACILITY TO INCLUDE AN EXISTING ADJACENT 1-STORY SPACE, AS PER APPROVED PLANS. AMENDMENT APPROVED 12/28/20 AMEND ALTERATIONS PERMIT CP-2020-004551 TO INCLUDE EXTERIOR FENCED AREA FOR CHILLER AS PER APPROVED PLANS.

  33. License terminal eventFOUR HUMOURS WHISKEY: Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 823332 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  34. PermitAddition and/or Alteration

    Permit EP-2020-008600 · Completed

    Replace existing 200amp 3 phase service with new 400amp 3 phase service. Install power for elevator and associated circuits as per 2017 nec

  35. PermitRough-In

    Permit EP-2020-008603 · Completed

    Rough-In Permit for EP-2020-008600 Replace existing 200amp 3 phase service with new 400amp 3 phase service. Install power for elevator and associated circuits as per 2017 nec

  36. ViolationLIQUID PETROLEUM GASES

    Case CF-2020-060072 · Violation VI-2020-033686 · Code FC-13-3809.12 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  37. ViolationFIRE SYSTEMS MAINTAINED

    Case CF-2020-060072 · Violation VI-2020-033685 · Code FC-13-901.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  38. InvestigationL&I investigation

    Case CF-2020-060072 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  39. ViolationEXTENSION CORDS

    Case CF-2020-060072 · Violation VI-2020-033533 · Code FC-13-605.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  40. ViolationFLAMMABLE LIQUID STORAGE

    Case CF-2020-060072 · Violation VI-2020-033534 · Code FC-13-2404.17.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  41. ViolationNEW USE

    Case CF-2020-060072 · Violation VI-2020-033532 · Code A-301.1/65 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  42. PermitChange of Use

    Permit ZP-2020-003370 · Issued

    Limited Industrial

  43. PermitShelter/Platform

    Permit GP-2020-003301 · Issued

  44. PermitAmend for conversion

    Permit 1027717 · Completed

    FOR THE AMENDMENT OF PERMIT AP#941124 TO ADJUST PARTITION LAYOUT AT THE 2ND FL TO ALIGN W/MOST RECENT ZONING USE APPROVAL (AP#1015625)

  45. PermitAdministrative

    Permit 1033349 · COMPLETED

    90 DAY CERTIFICATE OF OCCUPANCY FOR UNITS:102,204,205,207,208,209,215,& 212 (THIS IS THE 2ND (SECOND) T.C.O. NO OTHER WILL BE ISSSUED AFTER THIS ONE EXPIRES.)

  46. PermitUse

    Permit 1015625 · COMPLETED

    FOR BUSINESS AND PROFESSIONAL OFFICES IN AN EXISTING STRUCTURE WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS PERMIT.

  47. License issue eventFOUR HUMOURS WHISKEY: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 823332 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  48. PermitAdministrative

    Permit 1005866 · COMPLETED

    90 DAY CERTIFICATE OF OCCUPANCY FOR UNITS:102,204,205,207,208,209,215,& 212

  49. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 654871 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  50. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 654857 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  51. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 654659 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  52. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 654588 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  53. PermitPlumbing

    Permit 999184 · COMPLETED

    INSTALL 2 FIXTURES 1 EJECTOR 2 FLOOR DRAINS 1HWH AS PER 2004 PPC

  54. PermitNew Construction

    Permit 964812 · Completed

    CORRECT & LEGALIZE WORK DONE BY OTHERS EXISTING 600A WIRING AS PER PLANS PER 2008 NEC CORRECT & LEGALIZE WORK DONE BY OTHERS EXISTING 600A WIRING AS PER PLANS PER 2008 NEC

  55. PermitMechanical

    Permit 964654 · COMPLETED

    FOR THE INSTALLATION OF UNIT HEATERS, DUCTWORK, REGISTERS/DIFFUSERS, AND ALL OTHER WORK FOR GROUP A-2 AND B USE AND OCCUPANCY CLASSIFICATION AS ON THE 2ND FL PER APPROVED PLANS.

  56. PermitAddition and/or Alteration

    Permit 965518 · Expired

    FOR THE RECONSTRUCTION OF DETERIORATED BRICK SUPPORT STRUCTURE AS PER THE ENGINEER'S REPORT AND APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ALL OTHER WORK.

  57. InvestigationBP_BLDG

    Case 654659 · CLOSED

    City marked the record closed; open the case for the closing reason.

  58. InvestigationBP_BLDG

    Case 654691 · PASSED

    The cited inspection visit was marked passed.

  59. InvestigationBP_BLDG

    Case 654857 · CLOSED

    City marked the record closed; open the case for the closing reason.

  60. InvestigationBP_BLDG

    Case 654866 · PASSED

    The cited inspection visit was marked passed.

  61. InvestigationBP_BLDG

    Case 654871 · CLOSED

    City marked the record closed; open the case for the closing reason.

  62. PermitAddition and/or Alteration

    Permit 941124 · Completed

    TO COMPLY CASE VIOLATIONS #654871, #654866, #654857 & #654691 FOR LEGALIZATION OF WORK, AND TO PROVIDE RATED ASSEMBLY RECONFIGURATIONS INCLUDING INTUMENSCENT PAINT APPLICATION, INTERIOR PARTITION INSTALLATION, PLUMBING FIXTURE INSTALLATION, ACCESSIBLE RESTROOMS, RATED PARTITION WALLS, RATED SHAFT ENCLOSURE ASSEMBLIES, AND WALL/FLOOR/CEILING FINISHING. (IEBC 2009, CHANGE IN OCCUPANCY CLASSIFICATION, HIGHER HAZARD) **SEPARATE PA DEPT OF LABOR & INDUSTRY PERMITS REQ'D FOR PROPOSED ELEVATOR INSTALLATION. SEPARATE PERMITS REQ'D FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION SYSTEM INSTALLATIONS.** 3/23/2021: FOR AMENDMENT REVISIONS TO REVISE CONFIGURATION OF TENANT ENTRY DOOR LOCATION FOR SPACE #210 AND CORRIDOR #104 LAYOUT FOR VESTIBULE INSTALLATION. 6/4/2021: FOR AMENDMENT REVISIONS TO PROVIDE DETAILS ASSOCIATED WITH FIRE ESCAPE PLATFORM INSTALLATION, TO INCLUDE REVISED SPECIAL INSPECTIONS SCHEDULE, EXTERIOR STAIRS AND POST-INSTALLED MASONRY ANCHORS. 7/21/2021: FOR AMENDMENT REVISIONS TO PROVIDE PARITITION INSTALLATION TO CREATE TENANT SPACES M-3, M-4, AND M-5. USE REGISTRATION PERMITS TO BE REQUIRED FOR SPACES M-3, M-4, AND M-5 PRIOR TO OCCUPANCY. 3/14/2022: FOR AMENDMENT TO REVISE OCCUPANCY CLASSIFICATION OF TENANT SPACE L-2, WITH THE REVISION OF ASSEMBLY INSTALLATIONS AT ROOMS 214, 212, AND FLOOR/CEILING ASSEMBLY OF C-1.

  63. InvestigationBP_BLDG

    Case 654682 · PASSED

    The cited inspection visit was marked passed.

  64. PermitAlterations

    Permit 964810 · Completed

    LEGALIZE & CORRECT WORK DONE BY OTHERS 10WC 1MR 7LAVS 2F.D 1URINAL

  65. InvestigationBP_BLDG

    Case 654588 · CLOSED

    City marked the record closed; open the case for the closing reason.

  66. PermitNew Construction

    Permit 967811 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES-LEGALIZATION OF DUCKWORK FOR RESTROOM EXHAUST FAN For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans

  67. PermitPlumbing

    Permit 926538 · COMPLETED

    ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE ACCESSORY STORAGE AND FOOD PREP AREA FOR EXISTING RESTAURANT & DISTILLERY (SPACE M) IN SPACE C1 ON THE FIRST FLOOR; 2-SINKS,2-FLOOR DRAINS,1-EJECTOR AND 1-WATER HEATER.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  68. PermitPlumbing

    Permit 926539 · COMPLETED

    ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE ACCESSORY STORAGE AND FOOD PREP AREA FOR EXISTING RESTAURANT & DISTILLERY (SPACE M) IN SPACE C1 ON THE FIRST FLOOR; 2-TOILETS,2-VANITIES,3-BAR SINKS,DISHWASHER,ICE MAKER WITH TWO BINS,1-3COMP SINK AND 1-MOP SINK.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  69. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 366430 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  70. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 464040 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  71. PermitMechanical

    Permit 945503 · COMPLETED

    INSTALLATION OF HVAC EQUIPMENT & DUCT WORK PER PLANS

  72. PermitUse

    Permit 935146 · COMPLETED

    1ST FLOOR - SPACE E-2 - PROPOSED STORAGE OF BEER ONLY; 2ND FLOOR - SPACE G-1, M-1 AND M-2 - VACANT SPACES ( USE REGISTRATION PERMIT REQUIRE PRIOR TO OCCUPANCY), SPACE G-2 - PHOTO STUDIO (NO ACTIVITIES AS DEFINED IN 14-603 (13) OF PHILADELPHIA ZONING CODE), CREATION OF TWO (2) SPACES (I-1 & I-2) FOR USE AS FOLLOWS: I-1 - PHOTO STUDIO AND I-2 - MUSIC RECORDING STUDIO. CREATION OF ONE (1) SPACE (L-2) FROM TWO (2) SPACES (L-1 AND L-2) FOR A CARETAKER QUARTERS WITH ALL OTHER USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT.

  73. PermitMechanical

    Permit 948603 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  74. PermitAddition and/or Alteration

    Permit 926564 · Completed

    FOR LEVEL II ALTERATION TO CREATE OPENING IN NON BEARING PARTITION WALL TO INCREASE OCCUPANCY TO 50 PERSONS ON THE SECOND FLOOR LEVEL WITH NO CHANGE TO MEANS OF EGRESS APPROVED PER AP#760505 AND AP#726390. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  75. PermitElectrical

    Permit 941263 · COMPLETED

    INSTALL SUB PANEL IN STORAGE AREA ON 1ST FLOOR FEED FROM EXISTING PANEL IN DISTILLERY. MOVE EXISTING SUB PANEL FROM 1ST FLOOR REAR TO 2ND FLOOR REAR. ALL WORK TO CONFORM TO 2008 NEC.

  76. PermitSuppression

    Permit 941268 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  77. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620868 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  78. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620885 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  79. InvestigationBP_BLDG

    Case 654588 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  80. InvestigationBP_BLDG

    Case 654659 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  81. InvestigationBP_BLDG

    Case 654682 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  82. InvestigationBP_BLDG

    Case 654691 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  83. InvestigationBP_BLDG

    Case 654857 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  84. PermitNew Construction

    Permit 933054 · Expired

    INSTALL 100 VOLTAGE COMMECIAL SYSTEM 20AMP ELECTRICAL OUTLET FOR MIXER. INSTALL 20AMP EXTERIOR ELECTRICAL OUTLET INSTALL EXTERIOR DATA OUTLET AS PER NEC 2008

  85. InvestigationBP_BLDG

    Case 654866 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  86. InvestigationBP_BLDG

    Case 654871 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  87. PermitElectrical

    Permit 918676 · COMPLETED

    INSTALL 225A 3PHASE SERVICE, WIRE UP A WHISKEY DISTILLERY 40-CIRCUITS, 30-OUTLETS, 15-SWITCHES, 50-LIGHTS INCLUDING EM/EXIT LIGHTS AS PER NEC 2008 EAST DISTRICT

  88. PermitPlumbing

    Permit 918810 · COMPLETED

    INSTALL WATER & DRAIN LINES, & 7-FLOOR DRAINS, 3-FLOOR SINK, 6-KITCHEN SINKS, & WATER HEATER THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  89. PermitElectrical

    Permit 919520 · COMPLETED

    1-F/A CONTROL PNL, 1-ANNUN KEYPADS, 4-WALL HORN/STROBES, 17-STROBE, 16-MANUAL PULL STATIONS, 43-COMMON AREA SMOKE, 2-HEAT DETECTORS, 1-SPRINKLER WATER FLOW TRIP, 2-SPRINKLER VALVE TAMPER TRIPS, 1-KIT SUPP TRIP, 1-NAC PNL & 3-O/D AUDIBLE HORN/STROBES AS PER NFPA 72 CC DISTRICT

  90. PermitPlumbing

    Permit 922312 · COMPLETED

    REPLACE PVC RAIN LEADERS WITH CAST IRON.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  91. PermitMechanical

    Permit 913393 · COMPLETED

    TO LEGALIZE THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK IN SPACE C1 (CASE 654588). APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  92. PermitElectrical

    Permit 908642 · COMPLETED

    INSTALL 13 OUTLETS, 200 AMP WITH LIGHTS AS PER 2008 NEC (RESTAURANT)

  93. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620868 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  94. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620885 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  95. PermitUse

    Permit 858000 · COMPLETED

    ***PER ZBA PROVISO - TEMPORARY VARIANCE EXPIRES APRIL 1, 2021***FOR THE EXPANSION OF MINIATURE GOLF TO OUTDOOR SPACE TO INCLUDE OUTDOOR SEATING AREA AS PART OF AN EXISTING SEVENTEEN (17) VIDEO GAMES (AMUSEMENT ARCADE) AND INDOOR MINIATURE GOLF IN UNIT D ON 1ST FLOOR WITH ALL OTHER USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE (SIZE AND LOCATION AS SHOWN IN THE APPLICATION). NO SIGN ON THIS PERMIT.

  96. PermitMajor alteration

    Permit 857219 · COMPLETED

    INTERIOR FIT-OUT TO CREATE AN ARCADES IN TENANT SPACE "D".SPECE TO BE FULLY SPRINKLERED. SEPARATE PERMTI REQURIED TO BE REQUIRED FOR NEW ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEM WORK.

  97. ViolationPERMB- INSTALL HVAC SYS

    Case 654588 · Violation 5026395 · Code A-301.1/46 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  98. ViolationPERMP- INST FIXTURE W/O PERMIT

    Case 654588 · Violation 5026398 · Code A-301.1/58 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  99. ViolationPERMP- ALTER/REPAIR/REPL PLUMB

    Case 654588 · Violation 5026397 · Code A-301.1/55 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  100. ViolationPERME- INST COMMUN WIRE/EQUIP

    Case 654588 · Violation 5026396 · Code A-301.1/52 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  101. ViolationPERME- INST COMMUN WIRE/EQUIP

    Case 654659 · Violation 5092017 · Code A-301.1/52 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  102. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 654682 · Violation 4922804 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  103. ViolationPERME- INST COMMUN WIRE/EQUIP

    Case 654682 · Violation 4922805 · Code A-301.1/52 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  104. ViolationPERMP- INST NEW PLUMBING

    Case 654682 · Violation 4922806 · Code A-301.1/54 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  105. ViolationPENALTY- NO BLDG PERM INFO

    Case 654691 · Violation 4922843 · Code A-901.13/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  106. ViolationPERMB- INSTALL SECURITY GATE

    Case 654691 · Violation 4922842 · Code A-301.1/48 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  107. ViolationPERMP- INST NEW PLUMBING

    Case 654857 · Violation 5092031 · Code A-301.1/54 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  108. ViolationPENALTY- NO BLDG PERM INFO

    Case 654857 · Violation 5092032 · Code A-901.13/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  109. ViolationPENALTY- NO ELEC PERM INFO

    Case 654857 · Violation 5092033 · Code A-901.13/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  110. ViolationPENALTY- NO PLUMB PERM INFO

    Case 654857 · Violation 5092034 · Code A-901.13/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  111. ViolationPERMB- INSTALL HVAC SYS

    Case 654857 · Violation 5092029 · Code A-301.1/46 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  112. ViolationPERMB- INSTALL INT PARTITIONS

    Case 654857 · Violation 5092028 · Code A-301.1/34 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  113. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 654857 · Violation 5092030 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  114. ViolationPERMB- INSTALL SECURITY GATE

    Case 654866 · Violation 4922191 · Code A-301.1/48 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  115. ViolationPENALTY- NO BLDG PERM INFO

    Case 654866 · Violation 4922193 · Code A-901.13/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  116. ViolationARCHITECT/ENGINEER SERVICES

    Case 654866 · Violation 4922192 · Code A-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  117. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 654871 · Violation 5092044 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  118. ViolationPENALTY- NO ELEC PERM INFO

    Case 654871 · Violation 5092043 · Code A-901.13/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  119. InvestigationBP_BLDG

    Case 654857 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  120. InvestigationBP_BLDG

    Case 654866 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  121. InvestigationBP_BLDG

    Case 654871 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  122. InvestigationBP_BLDG

    Case 654588 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  123. InvestigationBP_BLDG

    Case 654659 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  124. InvestigationBP_BLDG

    Case 654682 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  125. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620885 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  126. InvestigationBP_BLDG

    Case 654691 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  127. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620868 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  128. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620923 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  129. AppealZoning board appeal

    Appeal 34241 · OPEN · Granted with conditions

    Related permit 858000 · PERMIT FOR THE EXPANSION OF MINIATURE GOLF TO OUTDOOR SPACE TO INCLUDE OUTDOOR SEATING AREA (ASSEMBLY AND ENTERTAINMENT) AS PART OF AN EXISTING SEVENTEEN (17) VIDEO GAMES (AMUSEMENT ARCADE) AND INDOOR MINIATURE GOLF IN UNIT D ON 1ST FLOOR W

  130. PermitMajor alteration

    Permit 869731 · COMPLETED

    FOR A PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION & LEVEL 2 ALTERATIONS TO CREATE A SPIRITS DISTILIING, BOTTLILNG, SALE, & TASTING FACILITY WITHIN EXISTING MIXED-USE INDUSTRIAL BUILDING INCLUDING ERECTION OF PARTITION WALLS TO CREATE HIGH-HAZARD BARRELL STORAGE & INTERIOR SEATING AREAS, REPLACEMENT OF EXTERIOR RAMP, & ALL OTHER FINISH WORK PER APPROVED PLANS; BUILDING TO BE FULLY SPRINKLERED & ALL COMBUSTIBLE LIQUIDS STORAGE TO BE MAINTAINED IN ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF THE PHILADELPHIA FIRE CODE. SEPARATE PERMIT REQ'D FOR ANY MECH., ELEC., PLUMB., & FIRESUPP. WORK.

  131. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620868 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  132. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620885 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  133. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 620923 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  134. PermitMajor alteration

    Permit 857531 · COMPLETED

    INTERIOR ALTERATIONS OF SPACE M TO CREATE DISTILLARY AND TASTING ROOM AS PER APPROVED PLANS. FOR ISSUANCE OF CERTIFICATE OF OCCUPANCY AND LAWFUL OCCUPANCY FOR TASTING ROOM.

  135. PermitUse

    Permit 886852 · COMPLETED

    FOR THE EXTENSION OF AN EXISTING LIMITED INDUSTRIAL USE (DISTILLERY) AND STI-DOWN RESTAURANT (EXISTING SPACE 'M') INTO SPACE 'C1' FOR ACCESSORY STORAGE AND FOOD PREP. NO SIGNS ON THIS PERMIT.

  136. PermitMajor alteration

    Permit 886853 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE ACCESSORY STORAGE AND FOOD PREP AREA FOR EXISTING RESTAURANT & DISTILLERY (SPACE M) IN SPACE C1 ON THE FIRST FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  137. PermitUse

    Permit 890630 · COMPLETED

    FOR A SIT DOWN RESTAURANT, LIMITED INDUSTRIAL, AND BUSINESS AND PROFESSIONAL OFFICE FOR TENANT SPACE M OF EXISTING BUILDING.

  138. PermitUse

    Permit 889316 · COMPLETED

    USE OF TENANT SPACE C2 ON THE 1ST FLOOR FOR LIMITED USE OF AGING AND BOTTLING DISTILLED SPIRITS, WHOLESALE SALES AND DISTRIBUTION, RETALE ED SALE OF FOOD AND BEVERAGES A SIT DOWN RESTAURANT AND TAKE OUT RESTAURANT SERVING FOOD AND DRINKS.

  139. PermitSuppression

    Permit 849444 · COMPLETED

    REPLACE DRY VALVE ON EXISTING AUTOMATIC FIRE SUPPRESSION SYSTEM AND INSTALLATION OF ADDITIONAL SPRINKLER HEADS IN ACCORDANCE WITH NFPA 13 TO TIE INTO EXISTING SPRINKLER SYSTEM IN TWO STORY BUILDING AS PER APPROVED PLANS.

  140. License issue eventALAMODAK INC **: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 772435 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  141. PermitUse

    Permit 865167 · COMPLETED

    PARTIAL CHANGE IN USE OF 2ND FLOOR SPACE M; ASSEMBLY AND ENTERTAINMENT USE NO CHANGE IN HEIGHT OR SQUARE FOOTAGE. (NO ACTIVITIES AS DEFINED IN 14-603-10)NO SIGN WITH THIS PERMIT.

  142. InvestigationCI INSP

    Case 620868 · CLOSED

    City marked the record closed; open the case for the closing reason.

  143. InvestigationCI INSP

    Case 620885 · CLOSED

    City marked the record closed; open the case for the closing reason.

  144. InvestigationCI INSP

    Case 620923 · CLOSED

    City marked the record closed; open the case for the closing reason.

  145. InvestigationCI INSP

    Case 620927 · PASSED

    The cited inspection visit was marked passed.

  146. License terminal eventALAMODAK INC: Food Preparing and Serving business license marked inactive

    License 727257 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  147. PermitUse

    Permit 858790 · COMPLETED

    USE IN SPACE C1 AS STORAGE. LEASE 2ND FLOOR OFFICE SPACE FOR SPACES J AND K

  148. PermitUse

    Permit 850053 · COMPLETED

    1ST FLOOR SPACE E-1 WHOLESALE SALES AND DISTRIBUTION OF MALT OR BREWED BEVERAGES; 2ND FLOOR FOR USE AS FOLLOWS: SPACES H3, I ,J, K, AND L-1 BUSINESS AND PROFESSIONAL OFFICES, SPACE G - CUSTOM HAND MADE CLOTHING; SPACES H1 & H2 - RADIO, TELEVISION AND RECORDING SERVICES; SPACE L2 - CARETAKER QUARTERS, SPACE M - PHOTO STUDIO (NO ACTIVITIES AS DEFINED IN 14-603 (13) OF PHILADELPHIA ZONING CODE), SPACE F2- VACANT (USE REGISTRATION PERMIT REQUIRE PRIOR TO OCCUPANCY) WITH ALL OTHER USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT.

  149. ViolationPERM Z- NEW USE

    Case 620868 · Violation 211946127 · Code A-301.1/65 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  150. ViolationCO- NEW USE OCCUPIED PRE-CO

    Case 620868 · Violation 211946128 · Code A-701.1/3 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  151. ViolationVIOL C&I MESSAGE

    Case 620868 · Violation 211946126 · Code A-000.0/10 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  152. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 620885 · Violation 211946068 · Code FC-13-1003 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  153. ViolationFIRE DOORS CLOSE/LATCH

    Case 620885 · Violation 211946069 · Code FC-13-703.23 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  154. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 620885 · Violation 211946070 · Code FC-13-915.1A · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  155. ViolationVENTILATION - BATHROOMS

    Case 620885 · Violation 211946071 · Code PM15-403.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  156. ViolationFIRE RESISTANCE RATING

    Case 620885 · Violation 211946072 · Code FC-13-703 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  157. ViolationVIOL C&I MESSAGE

    Case 620885 · Violation 211946073 · Code A-000.0/10 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  158. ViolationFIRE ALARM/DETECTION SYSTEMS

    Case 620885 · Violation 211946074 · Code FC-13-10573 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  159. ViolationSUPPRESSION SYSTEM REQ'D

    Case 620885 · Violation 211946075 · Code FC-13-903 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  160. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 620885 · Violation 211946076 · Code FC-13-915.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  161. ViolationCONTAINER CONTENTS

    Case 620923 · Violation 4778674 · Code FC-13-270181 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  162. ViolationNFPA 704 SIGNS

    Case 620923 · Violation 4778675 · Code FC-13-2703.5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  163. ViolationVIOL C&I MESSAGE

    Case 620923 · Violation 4778672 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  164. ViolationHAZMAT LICENSE REQUIRED

    Case 620923 · Violation 4778673 · Code FC-13-2701.5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  165. ViolationHOOD CLEANING

    Case 620927 · Violation 4578152 · Code FC-13-609.33 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  166. ViolationFIRE EXTINGUISHERS TAGGED

    Case 620927 · Violation 4578155 · Code FC-13-906.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  167. ViolationCOOKING EQUIPMENT POSITIONING

    Case 620927 · Violation 4578154 · Code FC-13-904121 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  168. ViolationVIOL C&I MESSAGE

    Case 620927 · Violation 4578151 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  169. ViolationWET CHEMICAL SYSTEM TEST

    Case 620927 · Violation 4578153 · Code FC-13-904.5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  170. InvestigationCI INSP

    Case 620868 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  171. InvestigationCI INSP

    Case 620885 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  172. InvestigationCI INSP

    Case 620923 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  173. InvestigationCI INSP

    Case 620927 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  174. PermitSuppression

    Permit 848541 · COMPLETED

    REPLACING 150 SPRINKLER HEADS.EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS

  175. PermitElectrical

    Permit 848622 · COMPLETED

    REPLACE OR REPAIR ANY BROKEN EMERGENCY LIGHTING IN COMMON HALLWAYS & STAIRWAYS AS PER NEC 2008 EAST DISTRICT

  176. PermitUse

    Permit 820233 · COMPLETED

    USE OF FIRST FLOOR (TENANT SPACE C) FOR LIMITED INDUSTRIAL USE (AGING AND BOTTLING DISTRILLED SPIRITS) WHOLESALE SALES AND DISTRIBUTION ;RETAIL SALES OF FOOD AN BEVERAGES. NO CHANGE IN BUILDING FOOTPRINT, HEIGHT, OR FLOOR AREA. NO SIGNS APPLIED FOR IN THIS APPLICATION. ALL OTHER PREVIOUSLY APPROVED USAGE TO REMAIN.

  177. PermitAlteration

    Permit 782881 · COMPLETED

    EZ STANDARD LIMITED COMMERCIAL ALTERATIONS & REPAIRS-OPENING EXISTING WINDOOWS THAT WERE CLOSED WITH CINDER BLOCK AND INSTALLING NEW WINDOWSFOR THE LIMITED DEMOLITION AND COMMERCIAL ALTERATIONS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  178. PermitAdministrative

    Permit 760505 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY FOR A PARTIAL CHANGE IN OCCUPANCY CLASSIFICATION FROM VACANT SPACE TO A SIT-DOWN RESTAURANT DINING ROOM (GROUP A-2), WITHIN PREVIOUSLY VACANT TENANT SPACE "F" (SEE KEY PLAN UNDER USE PERMIT, AP#716449), IN A PORTION OF THE SECOND FLOOR OF AN EXISTING STRUCTURE, AS PER PLANS; NO WORK UNDER THIS PERMIT NOT ALREADY AUTHORIZED UNDER AP#726390; COMPLIANCE WITH THE PHILADELPHIA FIRE & PROPERTY MAINTENANCE CODES REQUIRED PRIOR TO OCCUPANCY; BUILDING IS SPRINKLERED THROUGHOUT; NO SIGNS ON THIS PERMIT.

  179. PermitUse

    Permit 716449 · COMPLETED

    FOR THE EXPANSION OF AN EXISTING SIT DOWN RESTAURANT IN SPACE A ON 1ST FLOOR TO SPACE F ON 2ND FLOOR WITH ALL OTHER USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE (SIZE AND LOCATION AS SHOWN IN THE APPLICATION). NO SIGN ON THIS PERMIT.

  180. License issue eventALAMODAK INC: Handbill Distribution L&I license filing initially issued

    License 730813 · Expired

    License event. Registration does not prove present operation or storefront occupancy.

  181. License issue eventALAMODAK INC: Food Preparing and Serving business license initially issued

    License 727257 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  182. PermitSuppression

    Permit 743817 · COMPLETED

    EZ STANDARD KITCHEN FIRE SUPPRESSION- FOR THE INSTALLATION OF NEW WET CHEMICAL KITCHEN HOOD FIRE SUPPRESSION SYSTEM AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  183. AppealZoning board appeal

    Appeal 29143 · OPEN · Granted with conditions

    Related permit 716449 · PERMIT FOR THE EXPANSION OF AN EXISTING SIT DOWN RESTAURANT IN SPACE A ON 1ST FLOOR TO SPACE F ON 2ND FLOOR WITH ALL OTHER USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE (SIZE AND LOCATION AS SHOWN IN THE APPLICATION).

  184. PermitPlumbing

    Permit 724584 · COMPLETED

    ALTERATION: INTERIOR PLUMBING; SIT DOWN RESTAURANT IN SPACE A ON THE FIRST FLOOR TO SPACE B ON THE SECOND FLOOR - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  185. PermitElectrical

    Permit 737587 · COMPLETED

    INSTALL 11 LIGHT FIXTURES, 7 SWITCHES, 10 RECEPTACLES, 2 EXIT SIGNS, 2 SET OUTSIDE REMOTE HEADS, 6 EMERGENCY LIGHTS, 2 FAN MOTORS AND WIRE COMMERCIAL HOOD AS PER 2008 NEC (EAST DISTRICT)

  186. PermitMechanical

    Permit 681176 · COMPLETED

    INSTALL A NEW 13' HOOD WITH DUCTWORK, FANS, AND STAINLESS STEEL PANELS

  187. PermitMajor alteration

    Permit 726390 · COMPLETED

    INTERIOR ALTERATIONS TO EXISTING SPACE TO CREATE A SIT DOWN RESTAURANT ON THE FIRST FLOOR ONLY (SPACE A) AND FOR THE CONSTRUCTION OF AN ACCESSIBLE RAMP, AS PER APPROVED PLANS.

  188. License issue eventSWEET GRACE DISTILLING CO LLC (STATESIDE VODKA): Food Preparing and Serving business license initially issued

    License 702864 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  189. PermitUse

    Permit 653453 · COMPLETED

    PER PROVISO FIVE (5) YEAR TEMPORARY PERMIT FOR AN AMUSEMENT CENTER TO INCLUDE MINIATURE GOLF AND SEVENTEEN (17) VIDEO GAMES (AMUSEMENT ARCADE) IN UNIT D ON 1ST FLOOR IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT.

  190. AppealZoning board appeal

    Appeal 26942 · OPEN · Granted with conditions

    Related permit 653453 · PERMIT FOR AN AMUSEMENT CENTER TO INCLUDE MINIATURE GOLF AND SEVENTEEN (17) VIDEO GAMES (AMUSEMENT ARCADE) IN UNIT D ON 1ST FLOOR IN AN EXISTING STRUCTURE.

  191. PermitUse

    Permit 636364 · COMPLETED

    THE APPLICATION IS FOR THE USE OF SIT DOWN RESTAURANT ON THE FIRST FLOOR AT SPACE A OF AN EXISTING ATTACHED STRUCTURE WITH ALL THE OTHER PREVIOUSLY APPROVED USAGE IN OTHER SPACES.

  192. AppealZoning board appeal

    Appeal 26041 · CLOSED · Granted

    Related permit 636364 · PERMIT FOR THE USE OF SIT DOWN RESTAURANT ON THE FIRST FLOOR AT SPACE 'A' OF AN EXISTING ATTACHED STRUCTURE WITH ALL THE OTHER PREVIOUSLY APPROVED USAGE IN OTHER SPACES.

  193. License issue eventSWEET GRACE DISTILLING CO LLC (FEDERAL DISTILLING): Food Manufacturer / Wholesaler business license initially issued

    License 682794 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  194. PermitZoning/use

    Permit 628389 · COMPLETED

    THE APPLICATION IS FOR THE INSTALLATION OF TWO EXTERIOR FLAT WALL SIGN AS PER PLAN, ACCESSORY TO AN EXISTING LIMITED INDUSTRIAL IN TENANT SPACE 'M' (FIRST FLOOR - FRONTING N HANCOCK ST) WITHIN AN EXISTING STRUCTURE. NO CHANGE TO HEIGHT OR AREA OF STRUCTURE. NO CHANGE TO PARKING. NO CHANGE TO PREVIOUSLY APPROVED USES IN OTHER TENANT SPACES.

  195. PermitMajor alteration

    Permit 622137 · COMPLETED

    EXTERIOR ALTERATIONS FOR COMPLETION OF INSTALLATION OF STOREFRONT WINDOW & SIGNAGE ON FACADE AS PER PLANS AND SEE ZP628389 ADDITIONAL APPROVAL OF SIGNAGE

  196. PermitUse

    Permit 599466 · COMPLETED

    FIRST FLOOR TENANT SPACE M-LIMITED INDUTRIAL AND EAT IN RESTAURANT WITHIN THE SAME TENANT SPACE

  197. AppealZoning board appeal

    Appeal 24964 · OPEN · Granted

    Related permit 599466 · PERMIT FOR THE ADDITION OF EAT-IN RESTAURANT AS PART OF EXISTING LIMITED INDUSTRIAL IN TENANT SPACE 'M' ( FIRST FLOOR - FRONTING N HANCOCK ST) WITHIN AN EXISTING STRUCTURE ON FIRST FLOOR IN THE SAME BUILDING WITH ALL OTHER USES INCLUDING

  198. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 464040 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  199. PermitPlumbing

    Permit 605436 · COMPLETED

    INSTALL CURB TRAP & FAI PA1 2015-1072034 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  200. PermitElectrical

    Permit 590386 · COMPLETED

    WIRE 1ST FLOOR, INSTALL 20-OUTLET, 10-SWITCHES & LIGHTS, & EMERGENCY EXIT LIGHTS - EXISTING SERVICE (COMM) EAST DISTRICT

  201. PermitMechanical

    Permit 581035 · COMPLETED

    FOR THE INSTALLATION OF UNIT HEATERS, DUCTWORK, REGISTERS/DIFFUSERS, AND ALL OTHER WORK FOR GROUP H-3 USE AND OCCUPANCY CLASSIFICATION AS PER APPROVED PLANS.

  202. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 464040 · PASSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.

  203. PermitPlumbing

    Permit 595553 · COMPLETED

    REPLACE (12) 4" FLOOR DRAINS (COMMERICAL)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  204. PermitUse

    Permit 572082 · COMPLETED

    FOR THE CHANGE OF USE TO LIMITED INDUSTRIAL IN TENANT SPACE 'M' (FIRST FLOOR - FRONTING N HANCOCK ST) WITHIN AN EXISTING STRUCTURE. NO CHANGE TO HEIGHT OR AREA OF STRUCTURE. NO CHANGE TO PARKING. NO CHANGE TO PREVIOUSLY APPROVED USES IN OTHER TENANT SPACES. NO SIGNS ON THIS APPLICATION.

  205. PermitMajor alteration

    Permit 572130 · COMPLETED

    INTERIOR/BUILDING ENVELOPE DEMOLITION. PARTIAL CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II ALTERATIONS TO INCLUDE THE FOLLOWING: NEW ADA RESTROOMS, CREATION OF A ONE (1) - ONE (1) FIRE RATED CONTROL AREA AS PER TABLE 414.2.2 OF THE 2009 IBC, BOLLARDS FOR PROTECTION OF STORAGE TANKS, FIRE RATED DOORS, BOILER ROOM, EXTERIOR STAIRS, STOREFRONT, STRUCTURAL WORK, AND CONSTRUCTION OF WORK SPACE PLATFORM AS PER APPROVED PLANS. THIS PERMIT TO COVER CERTIFICATE OF OCCUPANCY FOR H-3 USE AND OCCUPANCY SPACE. SEPARATE PERMIT REQUIRED FOR CERTIFICATE OF OCCUPANCY FOR FUTURE TASTING ROOM. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK.

  206. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 464040 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  207. InvestigationCEASE INSP (likely: cease-operations compliance inspection)

    Case 405768 · PASSED

    Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked passed.

  208. ViolationPERM Z- NEW USE

    Case 464040 · Violation 3590361 · Code A-301.1/65 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  209. InvestigationCEASE INSP (likely: cease-operations compliance inspection)

    Case 404802 · PASSED

    Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked passed.

  210. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 464040 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  211. ViolationPERM - MUST POST

    Case 521505 · Violation 3834562 · Code A-302.8/30 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  212. PermitMajor alteration

    Permit 521505 · COMPLETED

    FOR RESOLUTION OF DEPT. OF L&I CASE# 405768 FOR PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION TO CREATE DWELLING UNIT, ARTIST & PHOTOGRAPHY STUDIO, COFFEE BEAM ROASTRY (NO RETAIL SALE), & ANIMAL DAY CARE SPACES WITHIN AN EXISTING TWO (2) STORY ABOVE GRADE MIXED-USE BUILDING. FOR LEVEL II ALTERATIONS TO INCLUDE ERECTION OF PARTITION WALLS FOR OFFICE, WORKSHOP, & TOILET SPACES FOR CERTIFICATION OF STUDIO, FACTORY, & DWELLING UNIT SPACES; WORK AREA TO BE FULLY SPRINKLERED. SEPARATE PERMIT REQUIRED FOR OCCUPANCY OF VACANT SPACES (SPC. B, F, G, I, L, & M), MECH., ELEC., PLUM., & FIRE SUPP. WORK.

  213. PermitUse

    Permit 535538 · COMPLETED

    FOR PART. RESOLUTION OF DEPT. OF L&I CASE# 404802 FOR USE AS ARTIST STUDIO & ARTISAN INDUSTRIAL IN SPACES 'A' & 'D,' ANIMAL SERVICES IN SPACE 'C,' WHOLESALE SALES & DISTRIBUTION IN SPACE 'E,' BUSINESS & PROFESSIONAL OFFICES IN SPACES 'H' & 'J,' & A CARETAKER QUATERS IN SPACE 'K' WITH ALL OTHER SPACES TO REMAIN VACANT; USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY. LOCATION OF SPACES AS SHOWN IN SUBMITTED KEYPLAN.

  214. InvestigationCEASE INSP (likely: cease-operations compliance inspection)

    Case 404802 · FAILED

    Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  215. InvestigationCEASE INSP (likely: cease-operations compliance inspection)

    Case 405768 · FAILED

    Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  216. PermitUse

    Permit 498599 · COMPLETED

    ARTIST STUDIO AND ARTISAN INDUSTRIAL (NO RETAIL SALES OR DISPLAY OF ARTS) IN THE SAME BUILDING WITH EXISTING DWELLING UNITS AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT.

  217. ViolationCO- BLDG OCCUPIED PRE-CO

    Case 405768 · Violation 3017713 · Code A-701.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  218. InvestigationCI INSP

    Case 405768 · CLOSED

    City marked the record closed; open the case for the closing reason.

  219. InvestigationCEASE INSP (likely: cease-operations compliance inspection)

    Case 405768 · FAILED

    Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  220. PermitUse

    Permit 498346 · COMPLETED

    GENERAL INDUSTRIAL (NO RETAIL SALES) IN SPACE A IN THE SAME BUILDING WITH EXISTING USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT. *** THIS PERMIT HAS ERROR IN PERMIT LANGUAGE; APPLICATION CLEARLY INDICATES SPACE B AS LOCATION OF "COFFEE ROASTING" WHICH IS CONSISTENT WITH "SITE/PROPERTY" LOCATION INFORMATION BUT PERMIT LANGUAGE INDICATES SPACE "A" IN ERROR ***

  221. PermitUse

    Permit 498053 · COMPLETED

    ARTIST STUDIO AND ARTISAN INDUSTRIAL (NO RETAIL SALES OR DISPLAY OF ARTS) IN SPACE A IN THE SAME BUILDING WITH EXISTING DWELLING UNITS AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT.

  222. ViolationPERM Z- NEW USE

    Case 404802 · Violation 3017697 · Code A-301.1/65 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  223. ViolationCAL PROHIBITED CONDUCT

    Case 404802 · Violation 3017696 · Code 19-2602.4/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  224. ViolationSPECIAL ASSEMBLY OCC LO

    Case 404802 · Violation 3017695 · Code 09-703.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  225. InvestigationCI INSP

    Case 404802 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  226. InvestigationCI INSP

    Case 404802 · CLOSED

    City marked the record closed; open the case for the closing reason.

  227. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 186418 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  228. ViolationLICENSE-VAC COMM BLDG

    Case 366430 · Violation 4977760 · Code PM-102.4/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  229. InvestigationCI INSP

    Case 366430 · PASSED

    The cited inspection visit was marked passed.

  230. InvestigationCSUINITIAL

    Case 255049 · PASSED

    The cited inspection visit was marked passed.

  231. InvestigationCSUINITIAL

    Case 255049 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  232. ViolationROOF PARTIALLY COLLAPSED

    Case 255049 · Violation 1906912 · Code PM-307.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  233. ViolationFLOOR/CEILING PARTIALLY COLL

    Case 255049 · Violation 1906913 · Code PM-307.1/6 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  234. InvestigationCSUINITIAL

    Case 255049 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  235. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 186418 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  236. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 186418 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  237. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 186418 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  238. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 186418 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  239. ViolationCOULD NOT ENTER

    Case 186418 · Violation 1719434 · Code A.CNE.000 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  240. InvestigationCI INSP

    Case 186418 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  241. InvestigationCI INSP

    Case 186418 · CLOSED

    City marked the record closed; open the case for the closing reason.

  242. ViolationFIRE DEPT CONNECT REP DAM CAPS

    Case 186418 · Violation 1719432 · Code FC-901.6/12 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  243. ViolationVIOL C&I MESSAGE

    Case 186418 · Violation 1719428 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  244. ViolationVACANT PROP STANDARD (likely: vacant-property enforcement standard)

    Case 186418 · Violation 1719429 · Code PM-306.0/1 · COMPLIED

    A legacy L&I label associated with vacant-property requirements. It may concern licensing, securing, or maintaining a vacant structure; the notice and cited code control, and this row alone does not prove the property is vacant now. City marked this violation complied with; check the resolution date and live case for what was accepted.

  245. ViolationLICENSE-VAC COMM BLDG

    Case 186418 · Violation 1719430 · Code PM-102.4/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  246. ViolationEXT S-WALLS REPAIR CRACKS

    Case 186418 · Violation 1719431 · Code PM-304.3/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  247. ViolationANNUAL CERT FIRE SUPP

    Case 186418 · Violation 1719433 · Code FC-914.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  248. InvestigationCI INSP

    Case 186418 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  249. PermitDemolition

    Permit 171948 · COMPLETED

    INTERIOR DEMOLITION OF NON BEARING PARTITIONS THROUGHOUT

  250. PermitZoning/use

    Permit 151108 · COMPLETED

    THE DEMO. OF AN EXISTING (2) STORY STRUCTURE, ERECTION OF (3) ROOFTOP ADDITIONS TO EXISTING STRUCTURE, CREATION OF A PARKING AREA FOR (13) CARS TO INCLUDE (1) H/C SPACE, ERECTION OF A 6'-0" HIGH FENCE. FOR USE AS A (25) DWELLING UNIT RESIDENTIAL BUILDING, NO SIGNS ON THIS APPLICATION.

  251. AppealZoning board appeal

    Appeal 5695 · CLOSED · Granted with conditions

    Related permit 151108 · PERMIT FOR THE DEMO. OF EXISTING (2) STORY STRUCTURE SO TO LEAVE ONE EXISTING (2) STORY STRUCTURE, ERECTION OF (3) ROOFTOP ADDITIONS TO EXISTING (2) STORY STRUCTURE WITH TERRACES, CREATION OF PARKING AREA FOR (22) CARS TO INCLUDE (1) H/C SP

  252. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 72278 · CLOSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. City marked the record closed; open the case for the closing reason.

  253. InvestigationCI INSP

    Case 72278 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  254. InvestigationCI INSP

    Case 72278 · CLOSED

    City marked the record closed; open the case for the closing reason.

  255. InvestigationCI INSP

    Case 72278 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  256. InvestigationCI INSP

    Case 72278 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 23, 2026, 10:22 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)