House report

1615 S Clarion St

2 bd1 ba2 stories728 sqftRSA5built 1920

Property at a glanceHouse

Owner-occupancy signal

2026 assessment
$263K OPA value, not a listing price
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

Published City assessments for this house against its block and ZIP. Dated City filings are marked on the same line. Select one to read it. Assessments are tax-roll values, not sale prices or appraisals.

$0$250K$500KZIP 19148 (Pennsport · Lower Moyamensing) median$285K200820122016202020242027
Property assessmentBlock median & rangeZIP 19148 (Pennsport · Lower Moyamensing) medianAssessmentPermit

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Every dated record7 events · exact dates, newest first
  1. PermitAlterations
  2. PermitAddition and/or Alteration
  3. PermitAddition and/or Alteration
  4. PermitAddition and/or Alterations
  5. PermitAddition and/or Alteration
  6. PermitElectrical
  7. PermitPlumbing

Informational only. Not investment advice or a consumer report (FCRA).

Verify the public record

$3,677/year estimated property tax

2026 taxable assessment $262,700 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $284,500. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 394626900
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

The property, on paper

OPA physical field record.

Bedrooms
2
Bathrooms
1
Stories
2
Interior
728 sqft livable area
Lot
624 sqft
Basement
Full, semi-finished city code B
Heat
Forced hot air city code A
Central air
No
Exterior condition
Average city code 4
Interior condition
Average city code 4
Quality grade
D assessor's grade
Zoning
RSA5 city zoning code

OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.

Block context

1600 block of S Clarion St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1613 S Clarion St  ·  1617 S Clarion St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 7 dated rows
  1. PermitAlterations

    Permit PP-2023-006075 · Completed

    Install new water heater in basement, install toilet, tub and lavatory on second floor install lavatory and toilet on first floor TOTAL 6 FIXTURES

  2. PermitAddition and/or Alteration

    Permit RP-2023-001452 · Completed

    FOR STRUCTURAL WORK ONLY TO REBUILD THE EXISTING STRUCTURE REAR 2ND FLOOR AND ROOF FRAMING, ROOF JOIST TO REPLACED / SISTERRED. INSTALL 36 INCH WIDE STAIR. SIZE AND LOCATION AS PER PLAN. ***NEW SEPARATE PERMIT REQUIRED FOR ANY INTERIOR ALTERATIONS ** ELECTRICAL, PLUMBING AND MECHANICAL WORKS**.

  3. PermitAddition and/or Alteration

    Permit EP-2023-002642 · Completed

    Provide new wiring for an existing house as per 2017 NEC Code. 25 Recessed fixtures. Arc and GFCI-protected circuits. Tamper-proof devices (4) ceiling fixtures 100 amp service.

  4. PermitAddition and/or Alterations

    Permit MP-2023-001141 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. Provide and install (2) Bathfans, (1) dryer vent (1) multizone heat pump system. System to be (3) zones, zone 1 to be the 1st floor controlled by a ducted air handler, Zones 2 and 3 to be ductless splits in the 2nd-floor bedrooms, 2nd floor bath to be controlled by zone 1. Provide and install all required equipment, duct distribution, and required components including line sets, drains, GRD and required controllers. Complete system pressure test, and evacuation, Charge system to spec, complete system start-up and testing.

  5. PermitAddition and/or Alteration

    Permit RP-2022-004193 · Completed

    EZ PERMIT STANDARDS ALTERATIONS For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS, UNDERPINNING AND EXCAVATIONS (I.E. DIGGING IN BASEMENT). ANY WORK/ALTERATIONS TO THE BASEMENT/CELLAR IS EXPRESSLY PROHIBITED UNLESS DOCUMENTED AS AN EXISTING HABITABLE SPACE WITH HEIGHTS AND MEANS OF EGRESS PER CONDITIONS OF THE EZ STANDARD. Separate permits required for Mechanical, Electric and Plumbing, ETC. **ENGINEER LETTER IN APPLICATION DOCUMENTS** **NO BASEMENT ALTERATIONS OF ANY KIND APPROVED** Project is an interior fit out where you are removing the interior finishes, fixtures, and non-bearing walls and reconfiguring the space. PER ENGINEER LETTER

  6. PermitElectrical

    Permit 450936 · COMPLETED

    REPLACE 100 AMP SERVICE IN A SINGLE FAMILY BUILDING AS PRE THE 2008 NEC

  7. PermitPlumbing

    Permit 175168 · COMPLETED

    REPLACE HOUSE TRAP W/BACKWATER VALVE

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 2:06 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)