Industrial property report

1829-31 N 19th St

14,525 sqftICMXbuilt 1915

Property at a glanceIndustrial building

Individual owner on record

2026 assessment
$479K OPA value, not a listing price
2027 published assessment
$813K Future roll, not the current tax bill
Neighborhood area
Brewerytown · Sharswood Approximate · based on ZIP 19121
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $813,400. It is not yet the billed-year tax basis.

$0$500K$1.0M$813K201420172020202320262027
Property assessmentAssessmentL&I violationPermitInspection

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record15 events · exact dates, newest first
  1. PermitFence
  2. PermitAlteration
  3. PermitPlumbing
  4. PermitMechanical
  5. PermitElectrical
  6. PermitUse
  7. PermitMajor alteration
  8. PermitMajor alteration
  9. InspectionPRECOURT (likely: pre-court compliance inspection)
  10. PermitMajor alteration
  11. InspectionCSUINITIAL
  12. L&I violationARCHITECT/ENGINEER SERVICES
  13. L&I violationFLOOR/CEILING PARTIALLY COLL
  14. L&I violationWALL FRACTURED
  15. InspectionCSUINITIAL

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $813,400. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 884351485
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Industrial property

Industrial building, recorded in the City's industrial category. The public record and owner trail follow.

What it is
Industrial building Ind Warehouse Masonry
Owner
Individual owner on record Individual name redacted
$ / sq ft
$56 below the $70 median for 3,574 industrial parcels citywide
Interior area
14,525 sqft
Lot size
15,684 sqft
Built
1915
Zoning
ICMX

Block context

1800 block of N 19th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1827 N 19th St  ·  1825 N 19th St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 15 dated rows
  1. PermitFence

    Permit GP-2022-008710 · Expired

    FOR THE INSTALLATION OF 8 FT. HIGH CHAIN LINK FENCE WITH 16 FT. WIDE DOUBLE-GATE AS PER PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  2. PermitAlteration

    Permit 812034 · COMPLETED

    ROOF REPLACEMENT - INSTALL A RUBBER TORCH DOWN ROOF SYSTEM (SFD)

  3. PermitPlumbing

    Permit 790291 · COMPLETED

    REPLACE ALL EXISTING PVC DRAINS WITH CAST IRON & PEX TUBING WITH COPPER TO THE FOLLOWING FIXTURES 2 RAINLEADERS, 3 PC BATH, MOP SINK, & LAUNDRY TUB/WASHING MACHINE, INSTALL NEW KITCHENETTE SINK - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  4. PermitMechanical

    Permit 790292 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.INSTALL MITSUBISHI WARM AIR SYSTEM IN INCLUDE AC AND ALL NEW DUCTWORK 124000 BTU'S 98% EFFI

  5. PermitElectrical

    Permit 776455 · COMPLETED

    UPGRADE SERVICE TO 400AMP,1 PHASE,WIRE 65 RECEPTACLES,100 LUMINARIES/LIGHTS INCLUDING EMERGENCY/EXIT PATH LIGHTS,25 TELE/DATA OUTLETS,2 CONDENSER 240V CIRCUITS AND 2 EXHAUST FANS PER 2008 NEC (OFFICE SPACE)

  6. PermitUse

    Permit 724208 · COMPLETED

    FOR THE LEGALIZATION OF THE USE AS BUSINESS & PROFESSIONAL OFFICE AND EQUIPMENT AND MATERIALS STORAGE YARDS AND BUILDINGS WITHIN AN EXISTING STRUCTURE. NO SIGNS ON THIS PERMIT.

  7. PermitMajor alteration

    Permit 714299 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS AND DOCUMENTATION OF GROUP B OFFICE OCCUPANCY WITH EQUIPMENT AND MATERIALS STORAGE WITHIN AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING NOT REQUIRED TO BE SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  8. PermitMajor alteration

    Permit 657182 · COMPLETED

    INSTALLATION OF NEW CONCRETE RAMP, STAIR ASSOCIATED RAILINGS AND EDGE PROTECTION WITH PLANTER BOX IN RIGHT-OF-WAY AS APPROVED BY STREETS DEPARTMENT. WORK ALSO INCLUDES INSTALLATION OF NEW GLAZED STOREFRONT SYSTEM WITH SINGLE DOOR; NO STRUCTURAL WORK TO EXISTING OPENING. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL OR PLUMBING WORK. SEPARATE PERMITS REQUIRED FOR USE REGISTRATION, ANY INTERIOR FITOUT AND CERTIFICATE OF OCCUPANCY.

  9. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 454942 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  10. PermitMajor alteration

    Permit 631352 · COMPLETED

    MAKE SAFE PERMIT - FOR REPAIRING CRACKED, DAMAGED, INTERIOR/EXTERIOR FINISHES TO RESOLVE CASE 454942. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6’ IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE 454942.

  11. InvestigationCSUINITIAL

    Case 454942 · CLOSED

    City marked the record closed; open the case for the closing reason.

  12. ViolationARCHITECT/ENGINEER SERVICES

    Case 454942 · Violation 3348074 · Code A-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  13. ViolationFLOOR/CEILING PARTIALLY COLL

    Case 454942 · Violation 3348075 · Code PM-307.1/6 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  14. ViolationWALL FRACTURED

    Case 454942 · Violation 3348076 · Code PM-307.1/9 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  15. InvestigationCSUINITIAL

    Case 454942 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 26, 2026, 5:11 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.