Apartment building report

1837 Blair St

4 stories4,200 sqftCMX2built 2018

Property at a glanceApartment building

Home Elite Ltd

2026 assessment
$1.2M OPA value, not a listing price
2027 published assessment
$1.1M Future roll, not the current tax bill
Neighborhood area
Fishtown · East Kensington Approximate · based on ZIP 19125
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $1,145,700. It is not yet the billed-year tax basis.

$0$1.0M$2.0M$1.1M2016201820202022202420262027
Property assessmentAssessmentPermitLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record53 events · exact dates, newest first
  1. CertificationSprinkler Certification
  2. LicenseFrankford Apartments LLC: Rental landlord or residential registration marked inactive
  3. CertificationSprinkler Certification
  4. LicenseHome Elite Ltd: Rental landlord or residential registration initially issued
  5. PermitCertificate of Occupancy (CO) (may inclu…
  6. CertificationFire Alarm Certification
  7. CertificationSprinkler Certification
  8. CertificationFire Alarm Certification
  9. LicenseFrankford Apartments LLC: Rental landlord or residential registration initially issued
  10. PermitPlumbing
  11. PermitMechanical
  12. PermitPlumbing
  13. PermitPlumbing
  14. PermitPlumbing
  15. PermitPlumbing
  16. PermitPlumbing
  17. PermitPlumbing
  18. PermitPlumbing
  19. PermitMechanical
  20. PermitMechanical
  21. PermitMechanical
  22. PermitMechanical
  23. PermitMechanical
  24. PermitMechanical
  25. PermitPlumbing
  26. PermitPlumbing
  27. PermitPlumbing
  28. PermitPlumbing
  29. PermitPlumbing
  30. PermitPlumbing
  31. PermitElectrical
  32. PermitElectrical
  33. PermitElectrical
  34. PermitElectrical
  35. PermitElectrical
  36. PermitElectrical
  37. PermitSuppression
  38. PermitSuppression
  39. PermitSuppression
  40. PermitSuppression
  41. PermitSuppression
  42. PermitSuppression
  43. PermitSuppression
  44. PermitAdministrative
  45. PermitAdministrative
  46. PermitAdministrative
  47. PermitAdministrative
  48. PermitAdministrative
  49. PermitAdministrative
  50. PermitAdministrative
  51. PermitNew construction
  52. PermitElectrical
  53. PermitZoning/use

Verify the public record

$1,680/year estimated property tax

2026 taxable assessment $120,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,145,700. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881098037
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $120,000 of $1,200,000 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Where the record looks off

Conflicts in City paperwork. Flags on the data, not the property.

Assessment and sale price disagree hard

Assessed at $1.1M, but it traded for $3,400,000 in 2023 — a 3.0× gap. Could be a non-market deed the record doesn't label, or an assessment that hasn't caught up.

Building report

Apartment building

Apartment building, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartment building Apts 5-50 Units Masonry
Owner
Home Elite Ltd
$ / sq ft
$273 above the $147 median for 2,826 apartments parcels citywide
Licensed units
9 active rental license
Interior area
4,200 sqft
Lot size
1,381 sqft
Stories
4
Built
2018
Zoning
CMX2

Recorded owner

Who's behind it

Home Elite Ltd · corporate / LLC owner

• Owns 12 properties across Philadelphia under this name, assessed at $13M combined
• Tax bills mail to 491 Old York Road Second Floor, Jenkintown PA, 19046 — outside Philadelphia
• Holds an active rental license for this address

Block context

1800 block of Blair St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1839-47 Blair St  ·  1839-47 Blair St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 25, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

Home Elite LtdActive

Rental · Initial issue date Dec 11, 2023 · Filed expiration Dec 10, 2026

Frankford Apartments LLCInactive

Rental · Initial issue date May 5, 2020 · Terminal license date Jul 2, 2024

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 53 dated rows
  1. CertificationSprinkler Certification

    Certification BC-2025-030966 · Certified

    Expires 2026-11-13

  2. License terminal eventFrankford Apartments LLC: Rental landlord or residential registration marked inactive

    License 841652 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  3. CertificationSprinkler Certification

    Certification BC-2024-000647 · Certified

    Expires 2024-12-28

  4. License issue eventHome Elite Ltd: Rental landlord or residential registration initially issued

    License 939738 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  5. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2023-009748 · Completed

    FOR CERTIFICATE OF OCCUPANCY FOR R-2 IN EXISTING STRUCTURE. (PERMIT TO CORRECT LANGUAGE ON C/O)

  6. CertificationFire Alarm Certification

    Certification BC-2023-023719 · Certified

    Expires 2024-11-18

  7. CertificationSprinkler Certification

    Certification BC-2022-017976 · Certified

    Expires 2023-11-30

  8. CertificationFire Alarm Certification

    Certification BC-2022-007882 · Certified

    Expires 2023-05-11

  9. License issue eventFrankford Apartments LLC: Rental landlord or residential registration initially issued

    License 841652 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  10. PermitPlumbing

    Permit 977627 · COMPLETED

    INSTALL 9 TOILETS, 6 SHOWERS, 3 TUBS, 9 LAVS, 9 KIT SINKS, 9 WASHERS, 2 EJECTORS AND 1 SUMP.

  11. PermitMechanical

    Permit 965694 · COMPLETED

    BLDG #7 (9) MULTI FAMILY / CONSTRUCT 9 NEW HVAC SYSTEMS THAT ARE COMPLETLY CONTAINED WITHIN THE RATED ASSEMBLIES OUTDOOR UNITS ON ROOF AS PER APPROVED STRUCTURAL PLAN CONSTSTRUCTION AS PER MANUFACTURERS REQUIREMENTS, THE IMC AND OUR EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  12. PermitPlumbing

    Permit 964620 · COMPLETED

    INSTALL 2" DOMESTIC WATER LINE FROM CURB TO BLDG AS PER 2004 PPC

  13. PermitPlumbing

    Permit 934879 · COMPLETED

    INSTALL WASTE AND WATER LINES FOR 5-TOILETS,5-LAVS,4-SHOWERS,2-KITCHEN SINKS,1-EJECTOR PUMP,2-WASHERS,2-DISHWASHERS,1-SUMP PUMP,HOUSE DRAIN,STACK AND 2-WATER HEATERS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  14. PermitPlumbing

    Permit 934880 · COMPLETED

    INSTALL WASTE AND WATER LINES FOR 5-TOILETS,5-LAVS,4-SHOWERS,2-KITCHEN SINKS,1-EJECTOR PUMP,2-WASHERS,2-DISHWASHERS,1-SUMP PUMP,HOUSE DRAIN,STACK AND 2-WATER HEATERS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  15. PermitPlumbing

    Permit 934881 · COMPLETED

    INSTALL WASTE AND WATER LINES FOR 5-TOILETS,5-LAVS,4-SHOWERS,2-KITCHEN SINKS,1-EJECTOR PUMP,2-WASHERS,2-DISHWASHERS,1-SUMP PUMP,HOUSE DRAIN,STACK AND 2-WATER HEATERS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  16. PermitPlumbing

    Permit 934924 · COMPLETED

    INSTALL WASTE AND WATER LINES FOR 5-TOILETS,5-LAVS,4-SHOWERS,2-KITCHEN SINKS,1-EJECTOR PUMP,2-WASHERS,2-DISHWASHERS,1-SUMP PUMP,HOUSE DRAIN,STACK AND 2-WATER HEATERS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  17. PermitPlumbing

    Permit 934936 · COMPLETED

    INSTALL WASTE AND WATER LINES FOR 5-TOILETS,5-LAVS,4-SHOWERS,2-KITCHEN SINKS,1-EJECTOR PUMP,2-WASHERS,2-DISHWASHERS,1-SUMP PUMP,HOUSE DRAIN,STACK AND 2-WATER HEATERS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  18. PermitPlumbing

    Permit 934937 · COMPLETED

    INSTALL WASTE AND WATER LINES FOR 5-TOILETS,5-LAVS,4-SHOWERS,2-KITCHEN SINKS,1-EJECTOR PUMP,2-WASHERS,2-DISHWASHERS,1-SUMP PUMP,HOUSE DRAIN,STACK AND 2-WATER HEATERS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  19. PermitMechanical

    Permit 934374 · COMPLETED

    NEW CONSTRUCTION DUPLEX INSTAL 2-2 TON A/C SYSTEM WITH 4000 BTU 95% HEATERS. INSTALL ALL DUCTWORK

  20. PermitMechanical

    Permit 934389 · COMPLETED

    NEW CONST DUPLEX INSTAL 2-2 TON A/C SYSTEM WITH 40000 BTU 95% HEATERS. INSTALL ALL DUCTWORK0

  21. PermitMechanical

    Permit 934390 · COMPLETED

    NEW CONST DUPLEX INSTAL 2-2 TON A/C SYSTEM WITH 40000 BTU 95% HEATERS. INSTALL ALL DUCTWORK0

  22. PermitMechanical

    Permit 934392 · COMPLETED

    NEW CONST DUPLEX INSTAL 2-2 TON A/C SYSTEM WITH 40000 BTU 95% HEATERS. INSTALL ALL DUCTWORK0

  23. PermitMechanical

    Permit 934393 · COMPLETED

    NEW CONST DUPLEX INSTAL 2-2 TON A/C SYSTEM WITH 40000 BTU 95% HEATERS. INSTALL ALL DUCTWORK0

  24. PermitMechanical

    Permit 934375 · COMPLETED

    NEW CONST DUPLEX INSTAL 2-2 TON A/C SYSTEM WITH 40000 BTU 95% HEATERS. INSTALL ALL DUCTWORK0

  25. PermitPlumbing

    Permit 934250 · COMPLETED

    INSTALL CURB TRAP, FAI & HOUSE DRAIN PA20183442932 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  26. PermitPlumbing

    Permit 934251 · COMPLETED

    INSTALL CURB TRAP, FAI & HOUSE DRAIN PA20183442932 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  27. PermitPlumbing

    Permit 934246 · COMPLETED

    INSTALL CURB TRAP, FAI & HOUSE DRAIN PA20183442932 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  28. PermitPlumbing

    Permit 934254 · COMPLETED

    INSTALL CURB TRAP, FAI & HOUSE DRAIN PA20183442932 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  29. PermitPlumbing

    Permit 934252 · COMPLETED

    INSTALL CURB TRAP, FAI & HOUSE DRAIN PA20183442932 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  30. PermitPlumbing

    Permit 934253 · COMPLETED

    INSTALL CURB TRAP, FAI & HOUSE DRAIN PA20183442932 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  31. PermitElectrical

    Permit 931386 · COMPLETED

    WIRE DUPLEX WITH LIGHTS SWITCHES OUTLETS GFI SMOKE DETECTOR AND C/O DETECTORS

  32. PermitElectrical

    Permit 931385 · COMPLETED

    WIRE DUPLEX WITH LIGHTS SWITCHES OUTLETS GFI SMOKE DETECTOR AND C/O DETECTORS

  33. PermitElectrical

    Permit 931396 · COMPLETED

    WIRE UP DUPLEX WITH LIGHTS, SWITCHES, OUTLETS, GFIS SMOKE DETECTORS AND C/O DETECTORS AS PER 2008 NEC (EAST DIST)

  34. PermitElectrical

    Permit 931397 · COMPLETED

    WIRE UP DUPLEX WITH LIGHTS, SWITCHES, OUTLETS, GFIS SMOKE DETECTORS AND C/O DETECTORS AS PER 2008 NEC (EAST DIST)

  35. PermitElectrical

    Permit 931398 · COMPLETED

    WIRE UP DUPLEX WITH LIGHTS, SWITCHES, OUTLETS, GFIS SMOKE DETECTORS AND C/O DETECTORS AS PER 2008 NEC (EAST DIST)

  36. PermitElectrical

    Permit 931401 · COMPLETED

    WIRE UP DUPLEX WITH LIGHTS, SWITCHES, OUTLETS, GFIS SMOKE DETECTORS AND C/O DETECTORS AS PER 2008 NEC (EAST DIST)

  37. PermitSuppression

    Permit 912611 · COMPLETED

    FOR THE INSTALLATION OF A NFPA 13 D SYSTEM FOR A TWO FAMILY DWELLING. FIRE SUPPRESSION SYSTEM SERVICED BY TWO SEPARATE COMBINED ONE INCH FIRE SERVICE LINES WITH A WATER METER ASSEMBLY. ALL WORK TO BE DONE PER APROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13D STANDARD.

  38. PermitSuppression

    Permit 912613 · COMPLETED

    FOR THE INSTALLATION OF A NFPA 13 D SYSTEM FOR A TWO FAMILY DWELLING. FIRE SUPPRESSION SYSTEM SERVICED BY TWO SEPARATE COMBINED ONE INCH FIRE SERVICE LINES WITH A WATER METER ASSEMBLY. ALL WORK TO BE DONE PER APROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13D STANDARD.

  39. PermitSuppression

    Permit 918549 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D, WITH TWO, ONE-INCH FIRE SERVICE LINES, AS PER APPROVED PLANS. SEE APP# 912612 FOR APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA..

  40. PermitSuppression

    Permit 918608 · COMPLETED

    FOR THE INSTALLATION OF A NFPA 13 D SYSTEM FOR A TWO FAMILY DWELLING. FIRE SUPPRESSION SYSTEM SERVICED BY TWO SEPARATE COMBINED ONE INCH FIRE SERVICE LINES WITH A WATER METER ASSEMBLY. ALL WORK TO BE DONE PER APROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13D STANDARD. PLEASE SEE AP#912613 FOR APPROVED PLANS AND DOCUMENTATION.

  41. PermitSuppression

    Permit 912612 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D, WITH TWO, ONE-INCH FIRE SERVICE LINES, AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA..

  42. PermitSuppression

    Permit 918609 · COMPLETED

    FOR THE INSTALLATION OF A NFPA 13 D SYSTEM FOR A TWO FAMILY DWELLING. FIRE SUPPRESSION SYSTEM SERVICED BY TWO SEPARATE COMBINED ONE INCH FIRE SERVICE LINES WITH A WATER METER ASSEMBLY. ALL WORK TO BE DONE PER APROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13D STANDARD. PLEASE SEE AP#912613 FOR APPROVED PLANS AND DOCUMENTATION.

  43. PermitSuppression

    Permit 912614 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITN NFPA 13R, WITH A TWO-INCH FIRE SERVICE LINE; FOR THE INSTALLATION OF A BACKFLOW PREVENTION ASSEMBLY, AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  44. PermitAdministrative

    Permit 893588 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY OF BUILDING 1 FOR A DUPLEX. SEE PERMIT 875560 FOR FLANS.

  45. PermitAdministrative

    Permit 893589 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY OF BUILDING 2 FOR A DUPLEX. SEE PERMIT 875560 FOR FLANS.

  46. PermitAdministrative

    Permit 893590 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY OF BUILDING 3 FOR A DUPLEX. SEE PERMIT 875560 FOR FLANS.

  47. PermitAdministrative

    Permit 893591 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY OF BUILDING 4 FOR A DUPLEX. SEE PERMIT 875560 FOR FLANS.

  48. PermitAdministrative

    Permit 893592 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY OF BUILDING 5 FOR A DUPLEX. SEE PERMIT 875560 FOR FLANS.

  49. PermitAdministrative

    Permit 893593 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY OF BUILDING 6 FOR A DUPLEX. SEE PERMIT 875560 FOR FLANS.

  50. PermitAdministrative

    Permit 875560 · COMPLETED

    TO AMEND EXISTING BUILDING PERMIT #734569 TO LOWER SPRINKLER SYSTEM REQUIREMENTS AND RECORD PLAN AND FACADE CHANGES TO THE MULTI-FAMILY UNIT INCLUDING CHANGE IN ELEVATION TO ADD A PARTIAL FOURTH FLOOR AS PER PLANS. BUILDING TOTAL HEIGHT SHALL NOT EXCEED 38 FT. FOR CERTIFICATE OF OCCUPANCY FOR BUILDING 7. SEPARATE PERMITS REQUIRED FOR CERTIFICATE OF OCCUPANCY FOR BUILDING 1-6.

  51. PermitNew construction

    Permit 734569 · COMPLETED

    FOR THE ERECTION OF ONE (1) THREE-STORY SEMI-DETACHED STRUCTURE (SEVEN (7) TOTAL BUILDINGS) WITH PILOT HOUSES AND ROOF DECKS. BUILDINGS 1-6 TO BE USED A TWO-FAMILY DWELLINGS AND BUILDING 7 TO BE USED AS AN NINE-FAMILY DWELLING. ALL BUILDINGS SHALL BE FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 STANDARDS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS ** SEPARATE PERMITS REQUIRED FOR CERTIFICATES OF OCCUPANCY FOR EACH BUILDING. **

  52. PermitElectrical

    Permit 758657 · COMPLETED

    INSTALL WIRE & DEVICES FOR LIGHTS, POWER, COMMUNICATIONS, 9 UNIT APART BLDG, INSTALL NEW 600AMP 120/208V ELECTRIC SERVICE WITH 9 APARTMENT SERVICES, 1 HOUSE SERVICE AND 1 FIRE PUMP SERVICE AS PER 2008 NEC (EAST DISTRICT) INSTALL FIRE ALARM SYSTEM AS PER NFPA72

  53. PermitZoning/use

    Permit 683419 · COMPLETED

    FOR THE ERECTION OF A SEMI-DETACHED STRUCTURE ( NTE 38' HIGH); PILOTHOUSE ACCESS BY A ROOF DECK AND FOR THE ERECTION OF A GREEN ROOF ( COVER MIN 60% OF THE ROOFTOP)) FOR A MULTI-FAMILY HOUSEHOLD LIVING ( 21 DWELLING UNITS) WITH THREE(3) INTERIOR TYPE 1A BICYCLE SPACES AT FIRST FLOOR (SHOULD BE IN AN ACCESSIBLE ROUTE) ( SEE APP# 683418 FOR PLAN) . SIZE AND LOCATION AS SSHOWN IN THE APPLICATION.

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 5:30 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)