Commercial property report

2001 Market St

41 stories1,152,480 sqftCMX5built 1991

Property at a glanceOffices

Individual owner on record

2026 assessment
$183M OPA value, not a listing price
2027 published assessment
$185M Future roll, not the current tax bill
Neighborhood area
Rittenhouse · Logan Square Approximate · based on ZIP 19103
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $185,220,400. It is not yet the billed-year tax basis.

$0$125M$250M$185M1994200020062012201820242027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record786 events · exact dates, newest first
  1. PermitAddition and/or Alteration
  2. PermitAddition and/or Alterations
  3. PermitAlterations
  4. PermitAddition and/or Alteration
  5. PermitAddition and/or Alteration
  6. PermitAddition and/or Alterations
  7. PermitAddition and/or Alteration
  8. PermitAddition and/or Alteration
  9. CertificationSmoke Control Certification
  10. CertificationEmergency and Standby Power Systems Certification
  11. PermitAddition and/or Alteration
  12. PermitAddition and/or Alterations
  13. PermitAlterations
  14. PermitAddition and/or Alterations
  15. PermitAddition and/or Alteration
  16. CertificationSpecial Hazards Certification
  17. CertificationSprinkler Certification
  18. PermitAddition and/or Alteration
  19. PermitAddition and/or Alterations
  20. PermitAddition and/or Alteration
  21. PermitAddition and/or Alterations
  22. PermitAddition and/or Alteration
  23. CertificationSmoke Control Certification
  24. CertificationDamper Certification
  25. LicenseCOMMERCE DU JOUR CORP: Food Preparing and Serving (30+ SEATS) business license marked inactive
  26. CertificationSpecial Hazards Certification
  27. CertificationSpecial Hazards Certification
  28. CertificationFire Alarm Certification
  29. CertificationEmergency and Standby Power Systems Certification
  30. PermitAddition and/or Alteration
  31. PermitAddition and/or Alteration
  32. InspectionL&I investigation
  33. PermitAddition and/or Alteration
  34. PermitAddition and/or Alteration
  35. PermitAddition and/or Alterations
  36. PermitAlterations
  37. PermitAddition and/or Alteration
  38. PermitAddition and/or Alteration
  39. PermitAddition and/or Alterations
  40. PermitAddition and/or Alteration
  41. InspectionL&I investigation
  42. PermitAddition and/or Alterations
  43. CertificationSprinkler Certification
  44. PermitAddition and/or Alteration
  45. PermitAddition and/or Alterations
  46. PermitAddition and/or Alterations
  47. PermitAddition and/or Alteration
  48. PermitAlterations
  49. PermitAddition and/or Alteration
  50. PermitAddition and/or Alterations
  51. PermitAddition and/or Alterations
  52. PermitAddition and/or Alteration
  53. PermitAddition and/or Alteration
  54. PermitAddition and/or Alterations
  55. PermitAddition and/or Alterations
  56. PermitAddition and/or Alterations
  57. PermitAddition and/or Alteration
  58. PermitAlterations
  59. PermitAddition and/or Alteration
  60. PermitAddition and/or Alteration
  61. PermitAddition and/or Alteration
  62. PermitAddition and/or Alteration
  63. CertificationSpecial Hazards Certification
  64. PermitAddition and/or Alteration
  65. CertificationFacade Report
  66. PermitAddition and/or Alteration
  67. PermitAddition and/or Alteration
  68. PermitAddition and/or Alterations
  69. PermitAddition and/or Alterations
  70. PermitAddition and/or Alterations
  71. PermitAddition and/or Alteration
  72. CertificationFire Alarm Certification
  73. PermitAddition and/or Alteration
  74. PermitAlterations
  75. PermitAlterations
  76. PermitAddition and/or Alteration
  77. PermitAddition and/or Alterations
  78. PermitAddition and/or Alterations
  79. PermitAddition and/or Alterations
  80. PermitAlterations
  81. CertificationEmergency and Standby Power Systems Certification
  82. PermitAlterations
  83. PermitAddition and/or Alteration
  84. PermitAddition and/or Alterations
  85. PermitAddition and/or Alteration
  86. CertificationSmoke Control Certification
  87. PermitAddition and/or Alteration
  88. PermitAddition and/or Alteration
  89. PermitAddition and/or Alterations
  90. PermitAlterations
  91. PermitAddition and/or Alterations
  92. PermitAddition and/or Alterations
  93. PermitAddition and/or Alteration
  94. PermitAddition and/or Alteration
  95. PermitAddition and/or Alterations
  96. CertificationSpecial Hazards Certification
  97. CertificationSprinkler Certification
  98. PermitAddition and/or Alteration
  99. PermitAddition and/or Alterations
  100. PermitInterior Non-Load-Bearing Wall Demo.
  101. PermitAddition and/or Alteration
  102. PermitAlterations
  103. CertificationFire Alarm Certification
  104. PermitAddition and/or Alterations
  105. PermitAlterations
  106. PermitAddition and/or Alteration
  107. PermitAddition and/or Alteration
  108. PermitAddition and/or Alteration
  109. PermitAddition and/or Alteration
  110. PermitAddition and/or Alteration
  111. PermitAddition and/or Alteration
  112. PermitAddition and/or Alterations
  113. PermitAddition and/or Alteration
  114. CertificationSpecial Hazards Certification
  115. PermitAddition and/or Alterations
  116. PermitAddition and/or Alterations
  117. PermitAddition and/or Alteration
  118. InspectionL&I investigation
  119. PermitAlterations
  120. PermitAddition and/or Alterations
  121. PermitAddition and/or Alteration
  122. PermitAddition and/or Alteration
  123. PermitAddition and/or Alteration
  124. CertificationFire Alarm Certification
  125. PermitAlterations
  126. PermitAddition and/or Alterations
  127. PermitAddition and/or Alterations
  128. PermitAddition and/or Alteration
  129. PermitAddition and/or Alteration
  130. InspectionL&I investigation
  131. PermitAddition and/or Alteration
  132. PermitAddition and/or Alterations
  133. PermitAddition and/or Alterations
  134. PermitAlterations
  135. PermitAddition and/or Alteration
  136. PermitAlterations
  137. PermitAddition and/or Alteration
  138. PermitAddition and/or Alteration
  139. PermitRough-In
  140. L&I violationFACADES
  141. InspectionL&I investigation
  142. PermitAddition and/or Alteration
  143. PermitAddition and/or Alterations
  144. PermitAlterations
  145. PermitAddition and/or Alteration
  146. PermitAddition and/or Alterations
  147. PermitAddition and/or Alteration
  148. PermitAlterations
  149. PermitAddition and/or Alteration
  150. PermitAlterations
  151. PermitAddition and/or Alteration
  152. PermitAddition and/or Alteration
  153. PermitAddition and/or Alteration
  154. PermitAddition and/or Alterations
  155. PermitRough-In
  156. PermitAddition and/or Alterations
  157. CertificationSpecial Hazards Certification
  158. PermitAddition and/or Alteration
  159. PermitAddition and/or Alterations
  160. PermitAddition and/or Alterations
  161. PermitAddition and/or Alteration
  162. InspectionL&I investigation
  163. InspectionL&I investigation
  164. PermitAddition and/or Alterations
  165. PermitAlterations
  166. PermitAddition and/or Alterations
  167. LicensePHILADELPHIA PLAZA PHASE II: High Rise L&I license filing marked inactive
  168. PermitAddition and/or Alteration
  169. L&I violationSUBMISSION OF DEFICIENCIES
  170. L&I violationCOMMERCIAL SYSTEM TEST
  171. L&I violationFAIL OBTAIN LICENSE (Obtain the license identified in the notice)
  172. InspectionL&I investigation
  173. PermitAddition and/or Alterations
  174. PermitAddition and/or Alteration
  175. PermitNew Construction
  176. CertificationSpecial Hazards Certification
  177. CertificationSpecial Hazards Certification
  178. PermitAddition and/or Alterations
  179. PermitAddition and/or Alteration
  180. PermitAlterations
  181. PermitAddition and/or Alteration
  182. LicensePHILADELPHIA PLAZA-PHASE II: Hazardous Materials L&I license filing marked inactive
  183. PermitAddition and/or Alteration
  184. PermitAddition and/or Alteration
  185. PermitAddition and/or Alterations
  186. PermitAddition and/or Alterations
  187. PermitAddition and/or Alteration
  188. PermitAlterations
  189. PermitAddition and/or Alterations
  190. PermitAddition and/or Alteration
  191. PermitAddition and/or Alteration
  192. PermitAddition and/or Alterations
  193. PermitAddition and/or Alterations
  194. PermitAddition and/or Alterations
  195. PermitAddition and/or Alteration
  196. PermitAddition and/or Alteration
  197. PermitAlterations
  198. PermitAddition and/or Alterations
  199. InspectionL&I investigation
  200. L&I violationCOMPL CONCEAL- BLDG PERM WORK
  201. L&I violationARCHITECT/ENGINEER SERVICES
  202. InspectionL&I investigation
  203. PermitAddition and/or Alterations
  204. PermitAddition and/or Alteration
  205. PermitAddition and/or Alteration
  206. PermitAddition and/or Alteration
  207. PermitAddition and/or Alteration
  208. PermitAddition and/or Alterations
  209. PermitAddition and/or Alterations
  210. PermitAddition and/or Alteration
  211. PermitAddition and/or Alteration
  212. PermitAddition and/or Alteration
  213. PermitAddition and/or Alteration
  214. PermitAlterations
  215. PermitAddition and/or Alteration
  216. PermitAddition and/or Alteration
  217. PermitAddition and/or Alteration
  218. PermitAddition and/or Alterations
  219. PermitAddition and/or Alteration
  220. PermitAddition and/or Alteration
  221. CertificationDamper Certification
  222. PermitAddition and/or Alteration
  223. PermitAlterations
  224. PermitAddition and/or Alterations
  225. PermitAddition and/or Alteration
  226. PermitAddition and/or Alteration
  227. PermitAddition and/or Alterations
  228. PermitAddition and/or Alteration
  229. PermitAddition and/or Alterations
  230. PermitAddition and/or Alteration
  231. PermitAlterations
  232. PermitAddition and/or Alterations
  233. PermitAddition and/or Alteration
  234. PermitAddition and/or Alterations
  235. PermitAddition and/or Alterations
  236. PermitAddition and/or Alteration
  237. PermitAddition and/or Alterations
  238. PermitInterior Non-Load-Bearing Wall Demo.
  239. PermitAddition and/or Alteration
  240. PermitAddition and/or Alterations
  241. PermitInterior Non-Load-Bearing Wall Demo.
  242. PermitAddition and/or Alteration
  243. PermitAddition and/or Alterations
  244. PermitAddition and/or Alteration
  245. PermitAddition and/or Alteration
  246. InspectionL&I investigation
  247. PermitAddition and/or Alteration
  248. PermitAddition and/or Alteration
  249. PermitAddition and/or Alterations
  250. InspectionL&I investigation
  251. L&I violationFIREBLOCKING/DRAFTSTOPPING
  252. L&I violationSTORAGE IN BUILDINGS
  253. L&I violationFIRE SYSTEMS MAINTAINED
  254. L&I violationCEILING CLEARANCE
  255. L&I violationSMOKE BARRIERS/PARTITIONS
  256. L&I violationFIRE SYSTEMS MAINTAINED
  257. L&I violationOPEN JUNCTION BOXES
  258. L&I violationNFPA 704 SIGNS
  259. L&I violationEXTENSION CORDS
  260. PermitAddition and/or Alteration
  261. PermitAddition and/or Alterations
  262. PermitAddition and/or Alteration
  263. PermitAddition and/or Alteration
  264. PermitAddition and/or Alteration
  265. PermitAddition and/or Alteration
  266. PermitAddition and/or Alterations
  267. PermitAlterations
  268. PermitAlterations
  269. PermitAddition and/or Alterations
  270. PermitRough-In
  271. PermitAddition and/or Alteration
  272. PermitAddition and/or Alterations
  273. PermitAddition and/or Alteration
  274. PermitAddition and/or Alterations
  275. PermitAlterations
  276. PermitAddition and/or Alteration
  277. LicenseCOMMERCE DU JOUR CORP: Food Manufacturer / Wholesaler business license marked inactive
  278. PermitAddition and/or Alteration
  279. PermitAddition and/or Alteration
  280. PermitInterior Non-Load-Bearing Wall Demo.
  281. PermitAddition and/or Alteration
  282. PermitElectrical
  283. PermitPlumbing
  284. PermitSuppression
  285. PermitMechanical
  286. PermitMajor alteration
  287. PermitDemolition
  288. CertificationFacade Report
  289. PermitNew Construction
  290. PermitNew Construction
  291. PermitPlumbing
  292. PermitElectrical
  293. PermitSuppression
  294. PermitMechanical
  295. PermitMajor alteration
  296. LicenseCOMMERCE DU JOUR CORP: Food Manufacturer / Wholesaler business license initially issued
  297. PermitDemolition
  298. PermitSuppression
  299. PermitElectrical
  300. PermitElectrical
  301. PermitElectrical
  302. PermitMechanical
  303. PermitElectrical
  304. PermitElectrical
  305. PermitPlumbing
  306. PermitMechanical
  307. PermitElectrical
  308. PermitSuppression
  309. PermitMechanical
  310. PermitPlumbing
  311. PermitPlumbing
  312. PermitMajor alteration
  313. PermitElectrical
  314. PermitElectrical
  315. PermitMajor alteration
  316. PermitPlumbing
  317. PermitMechanical
  318. PermitElectrical
  319. PermitElectrical
  320. PermitMajor alteration
  321. PermitSuppression
  322. PermitMajor alteration
  323. PermitDemolition
  324. AppealBuilding standards appeal
  325. LicenseJOHN ROCCO JR: Food Estab, Retail Non-Permanent Location (Annual) L&I license filing marked inactive
  326. PermitElectrical
  327. PermitElectrical
  328. PermitElectrical
  329. PermitPlumbing
  330. PermitMechanical
  331. PermitSuppression
  332. PermitMajor alteration
  333. PermitElectrical
  334. PermitElectrical
  335. PermitElectrical
  336. PermitPlumbing
  337. PermitPlumbing
  338. PermitElectrical
  339. PermitMechanical
  340. PermitMechanical
  341. PermitMajor alteration
  342. PermitMajor alteration
  343. PermitSuppression
  344. PermitSuppression
  345. PermitElectrical
  346. PermitSuppression
  347. PermitMechanical
  348. PermitElectrical
  349. PermitMajor alteration
  350. PermitElectrical
  351. PermitElectrical
  352. PermitPlumbing
  353. PermitSuppression
  354. PermitElectrical
  355. PermitMechanical
  356. PermitPlumbing
  357. PermitMechanical
  358. PermitElectrical
  359. PermitMajor alteration
  360. PermitMajor alteration
  361. PermitElectrical
  362. PermitElectrical
  363. PermitElectrical
  364. PermitElectrical
  365. PermitElectrical
  366. PermitElectrical
  367. PermitMajor alteration
  368. PermitPlumbing
  369. PermitSuppression
  370. PermitMechanical
  371. PermitMajor alteration
  372. PermitElectrical
  373. PermitMechanical
  374. PermitElectrical
  375. PermitElectrical
  376. PermitElectrical
  377. PermitElectrical
  378. PermitElectrical
  379. PermitSuppression
  380. PermitPlumbing
  381. PermitElectrical
  382. PermitMechanical
  383. PermitSuppression
  384. PermitSuppression
  385. PermitPlumbing
  386. PermitElectrical
  387. PermitMechanical
  388. PermitElectrical
  389. PermitMajor alteration
  390. InspectionBP_BLDG
  391. InspectionPRECOURT (likely: pre-court compliance inspection)
  392. PermitMajor alteration
  393. PermitAlteration
  394. PermitElectrical
  395. PermitElectrical
  396. PermitElectrical
  397. PermitMajor alteration
  398. PermitMechanical
  399. PermitDemolition
  400. PermitSuppression
  401. PermitMechanical
  402. PermitPlumbing
  403. PermitElectrical
  404. PermitNew Construction
  405. PermitElectrical
  406. PermitAddition and/or Alteration
  407. PermitElectrical
  408. PermitMajor alteration
  409. PermitElectrical
  410. PermitSuppression
  411. PermitElectrical
  412. InspectionBP_BLDG
  413. PermitDemolition
  414. PermitMajor alteration
  415. PermitSuppression
  416. PermitPlumbing
  417. PermitMajor alteration
  418. PermitMechanical
  419. PermitElectrical
  420. InspectionBP_BLDG
  421. L&I violationPERMB- FINAL PRE-CO INSP
  422. InspectionBP_BLDG
  423. PermitElectrical
  424. PermitElectrical
  425. L&I violationPERMB- TO COMPLY VIOL
  426. L&I violationPENALTY- NO BLDG PERM INFO
  427. L&I violationPERMB- ALTER REPAIR INT PART (Building permit required for interior alteration or repair)
  428. L&I violationPERMB- FINAL PRE-CO INSP
  429. InspectionBP_BLDG
  430. PermitElectrical
  431. L&I violationPERMB- ALTER REP'R EXT PORTION
  432. L&I violationPERMB- EXTEND FIRE SUPP SYS
  433. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  434. InspectionBP_BLDG
  435. PermitElectrical
  436. PermitPlumbing
  437. PermitSuppression
  438. InspectionCI INSP
  439. PermitMajor alteration
  440. PermitMechanical
  441. PermitAlteration
  442. PermitZoning/use
  443. LicensePHILADELPIHA PLAZA PHASE II AKA COMMERCE SQ (EXPERT PARKING): Public Garage / Parking Lot business license marked inactive
  444. PermitDemolition
  445. AppealZoning board appeal
  446. PermitMajor alteration
  447. PermitDemolition
  448. PermitElectrical
  449. PermitAdministrative
  450. InspectionCI INSP
  451. InspectionCI INSP
  452. L&I violationGENERAL REQ.- CITE CODE SECTIO
  453. L&I violationFIRE RESISTANCE RATING
  454. L&I violationVIOL C&I MESSAGE
  455. L&I violationOPEN JUNCTION BOXES
  456. L&I violationVIOL C&I MESSAGE
  457. L&I violationGENERAL REQ.- CITE CODE SECTIO
  458. L&I violationL&I violation
  459. L&I violationGENERAL REQ.- CITE CODE SECTIO
  460. InspectionCI INSP
  461. InspectionCI INSP
  462. PermitDemolition
  463. PermitElectrical
  464. PermitPlumbing
  465. PermitElectrical
  466. PermitElectrical
  467. PermitElectrical
  468. PermitElectrical
  469. PermitMechanical
  470. PermitElectrical
  471. PermitElectrical
  472. PermitElectrical
  473. PermitMechanical
  474. PermitMajor alteration
  475. PermitDemolition
  476. PermitElectrical
  477. PermitSuppression
  478. PermitSuppression
  479. PermitPlumbing
  480. PermitMechanical
  481. PermitPlumbing
  482. PermitMajor alteration
  483. PermitPlumbing
  484. PermitSuppression
  485. PermitElectrical
  486. PermitMajor alteration
  487. PermitElectrical
  488. PermitSuppression
  489. PermitMechanical
  490. PermitMajor alteration
  491. PermitMajor alteration
  492. PermitAdministrative
  493. PermitElectrical
  494. PermitElectrical
  495. InspectionCI INSP
  496. PermitAdministrative
  497. PermitElectrical
  498. PermitElectrical
  499. PermitElectrical
  500. PermitElectrical
  501. InspectionCI INSP
  502. L&I violationAFES-COMM KITCH SERVICE & CERT
  503. L&I violationINT KITCHEN-REPLACE LINK/HEAD
  504. L&I violationVIOL C&I MESSAGE
  505. InspectionCI INSP
  506. PermitElectrical
  507. L&I violationVIOL C&I MESSAGE
  508. L&I violationHIRISE-PAY HIRISE FEE
  509. InspectionCI INSP
  510. PermitElectrical
  511. PermitElectrical
  512. PermitElectrical
  513. PermitNew Construction
  514. PermitPlumbing
  515. PermitMechanical
  516. PermitPlumbing
  517. PermitMajor alteration
  518. PermitMechanical
  519. PermitMajor alteration
  520. PermitSuppression
  521. PermitMajor alteration
  522. PermitSuppression
  523. PermitNew Construction
  524. PermitElectrical
  525. PermitElectrical
  526. PermitElectrical
  527. PermitSuppression
  528. PermitSuppression
  529. PermitSuppression
  530. PermitMechanical
  531. PermitPlumbing
  532. PermitPlumbing
  533. PermitMechanical
  534. PermitMechanical
  535. PermitMajor alteration
  536. PermitDemolition
  537. InspectionPRECOURT (likely: pre-court compliance inspection)
  538. PermitMajor alteration
  539. PermitPlumbing
  540. PermitMajor alteration
  541. PermitMechanical
  542. PermitMajor alteration
  543. PermitSuppression
  544. PermitMechanical
  545. PermitPlumbing
  546. PermitElectrical
  547. PermitElectrical
  548. PermitElectrical
  549. PermitMajor alteration
  550. PermitMajor alteration
  551. PermitSuppression
  552. PermitElectrical
  553. PermitSuppression
  554. PermitSuppression
  555. LicenseCITIZENS BANK OF PENNSYLVANIA: Dumpster License - Private Property L&I license filing initially issued
  556. PermitMechanical
  557. PermitElectrical
  558. PermitElectrical
  559. PermitAdministrative
  560. PermitPlumbing
  561. PermitSuppression
  562. PermitMajor alteration
  563. PermitSuppression
  564. PermitMechanical
  565. PermitElectrical
  566. PermitPlumbing
  567. PermitPlumbing
  568. LicenseTWO COMMERCE SQ MARATHON GRILL: Food Preparing and Serving (30+ SEATS) business license marked inactive
  569. PermitElectrical
  570. PermitAdministrative
  571. PermitMechanical
  572. PermitElectrical
  573. PermitElectrical
  574. PermitElectrical
  575. PermitElectrical
  576. PermitSuppression
  577. PermitSuppression
  578. PermitElectrical
  579. PermitMajor alteration
  580. PermitPlumbing
  581. PermitMechanical
  582. PermitSuppression
  583. PermitMajor alteration
  584. PermitDemolition
  585. PermitElectrical
  586. PermitMechanical
  587. PermitElectrical
  588. InspectionCI INSP
  589. InspectionCI INSP
  590. PermitMajor alteration
  591. PermitPlumbing
  592. PermitElectrical
  593. PermitUse
  594. PermitMajor alteration
  595. LicenseREAL FRESH INC (PAGANO'S MARKET): Dumpster License - Private Property L&I license filing marked inactive
  596. PermitSuppression
  597. PermitElectrical
  598. PermitElectrical
  599. PermitElectrical
  600. PermitMechanical
  601. PermitPlumbing
  602. PermitElectrical
  603. PermitSuppression
  604. PermitElectrical
  605. PermitSuppression
  606. PermitMajor alteration
  607. PermitElectrical
  608. PermitMajor alteration
  609. PermitPlumbing
  610. InspectionCI INSP
  611. PermitMajor alteration
  612. InspectionCI INSP
  613. PermitMechanical
  614. L&I violationVIOL C&I MESSAGE
  615. L&I violationFA-MONITORING COMPANY
  616. InspectionCI INSP
  617. PermitSuppression
  618. LicenseREAL FRESH INC (PAGANO'S MARKET): Dumpster License - Private Property L&I license filing initially issued
  619. PermitElectrical
  620. L&I violationVIOL C&I MESSAGE
  621. L&I violationEGRESS-ASSEM OCC SIGNS
  622. L&I violationFIRE-COMM KITCH EXHAUST CLEAN
  623. L&I violationAFES-COMM KITCH SERVICE & CERT
  624. InspectionCI INSP
  625. InspectionCI INSP
  626. InspectionCI INSP
  627. PermitMajor alteration
  628. PermitMajor alteration
  629. PermitZoning/use
  630. PermitMajor alteration
  631. LicenseFEDEX KINKOS OFFICE AND PRINT SVCS INC: Dumpster License - Private Property L&I license filing initially issued
  632. InspectionCI INSP
  633. PermitMechanical
  634. PermitSuppression
  635. AppealZoning board appeal
  636. PermitElectrical
  637. PermitElectrical
  638. PermitPlumbing
  639. PermitPlumbing
  640. L&I violationAFES-COMM KITCH SERVICE & CERT
  641. L&I violationEGRESS-ASSEM OCC SIGNS
  642. L&I violationVIOL C&I MESSAGE
  643. L&I violationFIRE-COMM KITCH EXHAUST CLEAN
  644. InspectionCI INSP
  645. PermitSuppression
  646. PermitMajor alteration
  647. PermitMechanical
  648. PermitAlteration
  649. PermitMajor alteration
  650. PermitMajor alteration
  651. PermitPlumbing
  652. PermitMechanical
  653. PermitMechanical
  654. PermitSuppression
  655. PermitElectrical
  656. PermitAdministrative
  657. PermitElectrical
  658. PermitElectrical
  659. PermitSuppression
  660. PermitSuppression
  661. PermitMechanical
  662. PermitPlumbing
  663. PermitMajor alteration
  664. PermitElectrical
  665. PermitMechanical
  666. PermitElectrical
  667. PermitSuppression
  668. LicenseCLEMENT CIZEWSKI (MODERN_RESTAURANTS): Dumpster License - Private Property L&I license filing marked inactive
  669. PermitMajor alteration
  670. PermitMechanical
  671. PermitElectrical
  672. PermitMajor alteration
  673. PermitElectrical
  674. PermitSuppression
  675. LicenseCOMMERCE DUJOUR CORP INC: Dumpster License - Private Property L&I license filing initially issued
  676. PermitSuppression
  677. PermitMajor alteration
  678. PermitElectrical
  679. InspectionBC INSP (likely: building-code inspection)
  680. PermitElectrical
  681. PermitElectrical
  682. PermitMechanical
  683. PermitPlumbing
  684. PermitMajor alteration
  685. InspectionCI INSP
  686. L&I violationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)
  687. L&I violationVIOL C&I MESSAGE
  688. L&I violationAFES-COMM KITCH SERVICE & CERT
  689. L&I violationFIRE-COMM KITCH EXHAUST CLEAN
  690. InspectionCI INSP
  691. PermitFast form building
  692. LicenseCOMMERCE DU JOUR CORP: Food Preparing and Serving (30+ SEATS) business license initially issued
  693. PermitAdministrative
  694. PermitPlumbing
  695. PermitMechanical
  696. PermitFast form building
  697. PermitZoning/use
  698. PermitElectrical
  699. PermitMechanical
  700. PermitSuppression
  701. PermitElectrical
  702. PermitElectrical
  703. LicensePHILADELPIHA PLAZA PHASE II AKA COMMERCE SQ (EXPERT PARKING): Public Garage / Parking Lot business license initially issued
  704. InspectionBC INSP (likely: building-code inspection)
  705. PermitSign
  706. PermitUse
  707. PermitElectrical
  708. PermitPlumbing
  709. PermitMechanical
  710. PermitElectrical
  711. PermitElectrical
  712. LicenseREAL FRESH INC (PAGANO'S MARKET): Food Preparing and Serving (30+ SEATS) business license initially issued
  713. PermitZoning/use
  714. PermitFast form building
  715. PermitElectrical
  716. PermitElectrical
  717. PermitPlumbing
  718. PermitMechanical
  719. PermitElectrical
  720. PermitFast form building
  721. PermitPlumbing
  722. PermitElectrical
  723. PermitMechanical
  724. PermitPlumbing
  725. PermitMajor alteration
  726. PermitElectrical
  727. PermitSuppression
  728. PermitMajor alteration
  729. PermitElectrical
  730. PermitFast form building
  731. PermitPlumbing
  732. PermitMajor alteration
  733. PermitSuppression
  734. PermitElectrical
  735. PermitMechanical
  736. PermitFast form building
  737. PermitNew Construction
  738. PermitMajor alteration
  739. PermitFast form building
  740. PermitMajor alteration
  741. PermitElectrical
  742. PermitFast form building
  743. PermitElectrical
  744. PermitMechanical
  745. PermitMajor alteration
  746. PermitElectrical
  747. PermitFast form building
  748. PermitElectrical
  749. PermitMechanical
  750. PermitFast form building
  751. PermitPlumbing
  752. PermitElectrical
  753. PermitMechanical
  754. PermitMajor alteration
  755. PermitFast form building
  756. PermitMajor alteration
  757. PermitElectrical
  758. PermitElectrical
  759. PermitElectrical
  760. InspectionCI HAZMAT
  761. L&I violationINT MATERIAL STORAGE
  762. L&I violationWORKMANLIKE- FIRE CODE
  763. PermitElectrical
  764. L&I violationCOO- MAINT/DAMAGE/FIRE/CONSTR
  765. L&I violationVIOL C&I MESSAGE
  766. InspectionCI HAZMAT
  767. PermitMechanical
  768. PermitFast form building
  769. PermitMajor alteration
  770. PermitPlumbing
  771. PermitElectrical
  772. PermitElectrical
  773. PermitMajor alteration
  774. PermitElectrical
  775. PermitMajor alteration
  776. PermitFast form building
  777. PermitFast form building
  778. PermitMajor alteration
  779. LicenseBEERSHEBA ENTERPRISE LLC (BIRDS BIRDS BIRDS): Food Preparing and Serving (30+ SEATS) business license marked inactive
  780. InspectionBC INSP (likely: building-code inspection)
  781. LicenseJOHN ROCCO JR: Food Estab, Retail Non-Permanent Location (Annual) L&I license filing initially issued
  782. LicensePHILADELPHIA PLAZA-PHASE II: Hazardous Materials L&I license filing initially issued
  783. LicenseTWO COMMERCE SQ MARATHON GRILL: Food Preparing and Serving (30+ SEATS) business license initially issued
  784. LicensePHILADELPHIA PLAZA PHASE II: High Rise L&I license filing initially issued
  785. LicenseBEERSHEBA ENTERPRISE LLC (BIRDS BIRDS BIRDS): Food Preparing and Serving (30+ SEATS) business license initially issued
  786. LicenseCLEMENT CIZEWSKI (MODERN_RESTAURANTS): Dumpster License - Private Property L&I license filing initially issued

Verify the public record

$2,556,035/year estimated property tax

2026 taxable assessment $182,600,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $185,220,400. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 883054361
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Offices, recorded in the City's offices category. The public record and owner trail follow.

What it is
Offices Off Bld Com No Gar Mason
Owner
Individual owner on record Individual name redacted
$ / sq ft
$161 above the $142 median for 753 offices parcels citywide
Corridor
Market West city commercial corridor
Interior area
1,152,480 sqft
Lot size
64,431 sqft
Stories
41
Built
1991
Zoning
CMX5

Block context

2000 block of Market St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 2005 Market St  ·  2000-24 Market St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
COMMERCE DU JOUR CORPInactive

Food Manufacturer / Wholesaler · Initial issue date Apr 1, 2019 · Terminal license date May 30, 2020

COMMERCE DU JOUR CORPInactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Dec 30, 2009 · Terminal license date Jun 29, 2025

PHILADELPIHA PLAZA PHASE II AKA COMMERCE SQ (EXPERT PARKING)Inactive

Public Garage / Parking Lot · Initial issue date Apr 17, 2009 · Terminal license date Mar 1, 2015

REAL FRESH INC (PAGANO'S MARKET)Active

Food Preparing and Serving (30+ SEATS) · Initial issue date Nov 28, 2008 · Filed expiration Apr 30, 2027

TWO COMMERCE SQ MARATHON GRILLInactive

Food Preparing and Serving (30+ SEATS) · Initial issue date May 26, 2004 · Terminal license date Dec 22, 2012

BEERSHEBA ENTERPRISE LLC (BIRDS BIRDS BIRDS)Inactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Mar 3, 2004 · Terminal license date Sep 27, 2006

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 786 dated rows
  1. PermitAddition and/or Alteration

    Permit EP-2026-005748 · Issued

    Fire Alarm: Install speakers/strobes, strobes, smoke detectors, relays, NAC Panel. All work per approved plans

  2. PermitAddition and/or Alterations

    Permit MP-2026-003397 · Issued

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK ACCOMMODATE THE 14TH FLOOR LEVEL OF AN EXISTING STRUCTURE. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS.** ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **

  3. PermitAlterations

    Permit PP-2026-007492 · Issued

    ALTERATIONS TO EXISTING COMMERCIAL BUILDING. . INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATERIALS SHALL BE METALLIC TO ROOF EXTENSION. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS Furnish and install (8) plumbing fixtures, (1) kitchen sink, (1) water closet, (1) lavatory, (3) floor drains/ indirect wastes as shown on plans and (2) water heaters, with piping, as per plans.

  4. PermitAddition and/or Alteration

    Permit EP-2026-005529 · Issued

    Provide and install 164 Cat6 plenum cables at 150' average. Provide and install 1 composite security cable to 5 card reader locations. All cabling will be installed per current NEC. No rescue systems work.

  5. PermitAddition and/or Alteration

    Permit EP-2026-005081 · Issued

    Install 292 light fixture, 13 exit, 84 switch, 120 receptacle, 9 floor receptacle, 12 furniture power, 7 equipment power, 1 meter. Refeed 2 208/120 volt panels. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**

  6. PermitAddition and/or Alterations

    Permit FP-2026-001106 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (133) SPRINKLER HEADS ON THE 14TH FLOOR, PER NFPA 13

  7. PermitAddition and/or Alteration

    Permit CP-2026-002257 · Issued

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE (SUITE 1400) ON THE 14TH FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  8. PermitAddition and/or Alteration

    Permit EP-2026-003774 · Completed

    Install receptacles & poke-thru(s) as per drawings and 2017 NEC.

  9. CertificationSmoke Control Certification

    Certification BC-2026-008410 · Certified

    Expires 2027-03-25

  10. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2026-007373 · Certified

    Expires 2027-02-14

  11. PermitAddition and/or Alteration

    Permit EP-2026-000344 · Completed

    Furnish and install 2 duplex outlets, 2 GFI's, 1 dedicated circuit and 3 floor cores, 14 downlights, 1 dimmer and 1 wall motion. Fire Alarm . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.

  12. PermitAddition and/or Alterations

    Permit MP-2026-000263 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate [1] VAV box, [1] thermostat, [7] diffusers, and provide air balancing.

  13. PermitAlterations

    Permit PP-2025-016635 · Completed

    Furnish and install [1] sink with 6 -gallon hot water heater - Connect to existing Sanitary, vent and domestic cold water lines. 2 FIXTURES.

  14. PermitAddition and/or Alterations

    Permit FP-2025-002556 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (13) SPRINKLER HEADS ON THE 11TH FLOOR, PER NFPA 13

  15. PermitAddition and/or Alteration

    Permit CP-2025-006217 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS FOR NEW TENANT FIT OUT FOR BUSINESS OCCUPANCY TO SUITE 1140 ON ELEVENTH FLOOR OF AN EXISTING BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  16. CertificationSpecial Hazards Certification

    Certification BC-2025-031042 · Certified

    Expires 2026-11-24

  17. CertificationSprinkler Certification

    Certification BC-2026-004590 · Certified

    Expires 2026-10-24

  18. PermitAddition and/or Alteration

    Permit EP-2025-008283 · Completed

    Replace existing light fixtures with new energy efficient light fixtures. Rework existing receptacle and furniture feed circuits to accommodate new layout. Relocate existing ceiling mounted speaker strobe that is in existing conference room approximately 6' . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  19. PermitAddition and/or Alterations

    Permit MP-2025-004682 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate [2] thermostats, relocate [6] diffusers, and provide air balance report in suite 2610

  20. PermitAddition and/or Alteration

    Permit EP-2025-008035 · Completed

    Installation of forty-five (45) low voltage Category 6 computer wires as per NEC 2017.

  21. PermitAddition and/or Alterations

    Permit FP-2025-001582 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (15) sprinkler heads in suite #2610, per NFPA 13 and local codes

  22. PermitAddition and/or Alteration

    Permit CP-2025-002630 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 26 TH FLOOR LEVEL OF AN EXISTING STRUCTURE (SUITE 2610). ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  23. CertificationSmoke Control Certification

    Certification BC-2025-019754 · Certified

    Expires 2026-07-28

  24. CertificationDamper Certification

    Certification BC-2025-019538 · Certified

    Expires 2026-07-24

  25. License terminal eventCOMMERCE DU JOUR CORP: Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 490721 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  26. CertificationSpecial Hazards Certification

    Certification BC-2025-013371 · Certified

    Expires 2026-05-19

  27. CertificationSpecial Hazards Certification

    Certification BC-2025-024301 · Certified

    Expires 2026-05-15

  28. CertificationFire Alarm Certification

    Certification BC-2025-013131 · Certified

    Expires 2026-03-17

  29. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-008520 · Certified

    Expires 2026-02-22

  30. PermitAddition and/or Alteration

    Permit EP-2024-012174 · Completed

    Furnish & install (7) new Cat 6 plenum cables for voice/data-2017 NEC.

  31. PermitAddition and/or Alteration

    Permit EP-2024-012150 · Completed

    Install (9) Cat 6 cables (14) office monitors 18/2 speaker wiring

  32. InvestigationL&I investigation

    Case CF-2024-114785 · PASSED

    The cited inspection visit was marked passed.

  33. PermitAddition and/or Alteration

    Permit EP-2024-012020 · Completed

    Install 66 light fixtures, 7 switches, and 8 receptacles as per 2017 NEC. Install 1 fire alarm device as per 2016 NFPA 72.

  34. PermitAddition and/or Alteration

    Permit EP-2024-009409 · Completed

    Install 235 light fixture, 10 exit, 108 switch, 53 receptacle, 14 floor receptacle, 4 furniture power, 2 exhaust fan power Fire Alarm: Install 5 strobe, 20 speaker/strobe, 2 smoke detector, 1 relay module, 1 NAC Panel . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  35. PermitAddition and/or Alterations

    Permit MP-2024-005458 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require the submission of construction and site plans. relocate [1] thermostat , relocate [4] diffusers, and provide air balance report. No penetrations to fire-rated assemblies.

  36. PermitAlterations

    Permit PP-2024-015197 · Completed

    INSTALL NEW FIXTURES WITH PIPING (2) kitchen sinks, (2) lavatories, (2) water closets and (2) hot water heaters,

  37. PermitAddition and/or Alteration

    Permit EP-2024-010939 · Completed

    STATEMENT OF WORK: HORIZONTAL CABLING: Cabling will be Superior/Essex Category 6 plenum rated 4-pair. • Provide and install sixteen (16) flush mount dual locations. • Provide and install ninety-four (94) furniture mount single locations. • Provide and install eighteen (18) surface mount dual wireless access point locations. • Provide and install eight (8) surface mount single room scheduler locations. • Provide and install seven (7) floor mount dual locations. • Provide and install six (6) flush mount triple locations. • Provide and install three (3) flush mount quad locations. • Provide and install thirty-seven (37) flush mount single locations. • Provide and install Panduit faceplates, surface mount boxes, floor frames and modular jacks as required for termination of the 4-pair cables installed at the workstation location. • Provide and install six (6) Panduit 48-port flat modular patch panels, each loaded with the required modular jacks. These will be installed at the appropriate closet location for termination of the 4-pair cables installed. • Provide and install six (6) Panduit 2U PatchLink horizontal cable managers with the patch panels to facilitate cable management. PATCH CORDS: • Furnish one hundred fifty (150) Panduit Category 6 patch cords, blue in color, 7’ in length. • Furnish twenty (20) Panduit Category 6 patch cords, black in color, 10’ in length. • Furnish ten (10) Panduit Category 6 patch cords, black in color, 20’ in length. • Furnish thirty-six (36) Panduit Category 6 patch cords, white in color, 3’ in length. RACKS & LADDER RACKING: • Provide and install the following: DESCRIPTION MFG P/N QTY 4-post rack w/ threaded rails - 84" high PANDUIT R4P 2 PatchRunner vertical cable manager w/ front & rear doors - 6" for 84" high rack PANDUIT PR2VD06 6 PatchRunner 7" front slack mgt spool for vertical channels PANDUIT PRSP7 12 Rack screws, #12-24 x .5" mounting screws PANDUIT S1224-C 1 18" wide, 10' l

  38. PermitAddition and/or Alteration

    Permit EP-2024-011050 · Completed

    Furnish and install one hundred fifty-eight (158) Category 6 plenum cables. Average cable pull is 150 feet.

  39. PermitAddition and/or Alterations

    Permit FP-2024-002406 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (7) SPRINKLER HEADS AS PER NFPA 13 ON 30TH FLOOR - SUITE 3000

  40. PermitAddition and/or Alteration

    Permit CP-2024-005809 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) TO THE 30TH FLOOR SUITE 3000 OF AN EXISTING BUILDING. TENANT SPACES TO BE USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE INSTALLATION OF NEW WALL PARTITIONS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT AS PER-APPROVED PLANS. ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK**IEBC 2018**EXISTING BUILDING FULLY SPRINKLERED** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**

  41. InvestigationL&I investigation

    Case CF-2024-114785 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  42. PermitAddition and/or Alterations

    Permit MP-2024-004582 · Completed

    FOR INSTALLATION OF HVAC EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS.

  43. CertificationSprinkler Certification

    Certification BC-2024-030646 · Certified

    Expires 2025-10-16

  44. PermitAddition and/or Alteration

    Permit EP-2024-009086 · Completed

    Furnish and install 103 duplex receptacles, 10 dedicated duplex receptacles, 4 GFI receptacles, 43 quad duplex receptacles, 2 L620R devices, 11 wall furniture feeds, 6 floor core furniture feeds, 19 floor cores, 2 water heater feeds, 5 FPB feeds, 8 chief boxes, 340 light fixture as per 2017 NEC. Install Fire Alarm as per drawings and 2016 NFPA 72.

  45. PermitAddition and/or Alterations

    Permit MP-2024-004244 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  46. PermitAddition and/or Alterations

    Permit FP-2024-002078 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (65) sprinkler heads on the 41st floor as per NFPA 13

  47. PermitAddition and/or Alteration

    Permit CP-2024-004342 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN OCCUPANCY TO EXISTING GROUP B OFFICES AT THE 41ST FLOOR. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK.

  48. PermitAlterations

    Permit PP-2024-011619 · Completed

    Furnish and Install [2] Kitchen Sinks, [2] Electric Water Heaters [2] Open Site Drains • Provide labor and materials to extend from existing sanitary, vent and domestic water mains as shown.

  49. PermitAddition and/or Alteration

    Permit EP-2024-007898 · Completed

    INSTALL 6 RECEPTACLE, 3 EMERGENCY LIGHT WITH EXIT SIGNS AND 8 EMERGENY LIGHTS. REPLACE EXISTING FLUORESCENT LIGHTING WITH LED LIGHTING ACCORDING TO THE 2017 NEC AND PER PLANS.

  50. PermitAddition and/or Alterations

    Permit FP-2024-001688 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (187) SPRINKLER HEADS AS PER NFPA 13

  51. PermitAddition and/or Alterations

    Permit FP-2024-001371 · Completed

    FOR THE INSTALLATION OF SPRINKLER HEADS IN ACCORDANCE WITH NFPA 13 ON THE SIXTEENTH AND SEVENTEENTH FLOOR LEVELS WITH EXISTING FIRE SERVICE LINE, BACKFLOW PREVENTION DEVICE, AND FIRE PUMP. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  52. PermitAddition and/or Alteration

    Permit CP-2024-003874 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) TO THE 8TH FLOOR OF AN EXISTINGSTRUCTURE. ALTERATIONS TO INCLUDE SELECTIVE PARTITION DEMOLITION AND THE ERECTION OF NEW PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**

  53. PermitAddition and/or Alteration

    Permit CP-2024-003879 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE FOR USE AS A GYMNASIUM ON 1ST FLOOR (ROOM 303), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. ****************SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. *********************************

  54. PermitAddition and/or Alterations

    Permit FP-2024-001290 · Completed

    FOR THE ALTERATION OF AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 WITH AN EXISTING BACKFLOW PREVENTION ASSEMBLY. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  55. PermitAddition and/or Alterations

    Permit FP-2024-001372 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 650 Sprinkler Heads

  56. PermitAddition and/or Alterations

    Permit MP-2024-002590 · Completed

    FOR THE INSTALLATION OF HVAC APPLICANCE, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSER PER APPROVED PLAN AND MANUFACTURER'S SPECIFICATIONS.

  57. PermitAddition and/or Alteration

    Permit EP-2024-006125 · Completed

    Install 1 plenum composite cable to 6 door locations on floor P1 . Install 1 plenum composite cable to 10 door locations on floor 15. Install 1 plenum composite cable to 08 door locations on floor 16. Install 1 plenum composite cable to 15 door locations on floor 17. Install card readers, locks and door contacts at the 39 door locations. All work will be completed per current NEC. No rescue systems wor

  58. PermitAlterations

    Permit PP-2024-008029 · Completed

    • Furnish and install [1] Sink, [1] Electric Water Heater, [1] Floor Drain and [1] Hub Drain • Provide labor and material to extend from existing sanitary, vent and domestic cold water.

  59. PermitAddition and/or Alteration

    Permit EP-2024-005612 · Completed

    Install Data and Security Wiring

  60. PermitAddition and/or Alteration

    Permit EP-2024-005699 · Completed

    nstall 188 Cat 6 cables 1 IT closet 20 office/ conference room TV monitors 3 Aces DDDPR with readers

  61. PermitAddition and/or Alteration

    Permit EP-2024-005485 · Completed

    Furnish & Install Power and Lighting Per Plans.-2017 nec. AMENDMENT: Furnish and install fire alarm as per plans.2016 NFPA-72.

  62. PermitAddition and/or Alteration

    Permit CP-2024-002630 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING 11TH FLOOR OFFICE SPACE (SUITE 1120) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  63. CertificationSpecial Hazards Certification

    Certification BC-2024-015901 · Certified

    Expires 2025-05-30

  64. PermitAddition and/or Alteration

    Permit EP-2024-004648 · Completed

    Furnish and Install Power and Lighting Per APPROVED DRAWINGS-2017 NEC **SEPARATE FIRE ALARM PERMIT REQ'D**

  65. CertificationFacade Report

    Certification BC-2024-014574 · Safe with Repair

    Expires 2029-05-29

  66. PermitAddition and/or Alteration

    Permit EP-2024-004092 · Completed

    Install: 180 light fixtures, 8 exit, 55 switch, 7 UL924 device, 1 time clock, 106 receptacle, 8 floor receptacle, 10 furniture power, 44 equipment power, 1 meter, 1 bus switch, 1 208/120 volt panel. Fire Alarm: Install 27 speaker/strobe, 1 strobe, 1 NAC panel, 4 door holder, 7 relay.. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  67. PermitAddition and/or Alteration

    Permit EP-2024-004016 · Completed

    AMEND Furnish and install additional scope of work. The following equipment and plenum Category 6 cabling to support new system. SMS-NET Sound Masking System Quantity Model Description 367 SMS-NET-STR Speakers 4 SMS-NET-HDN Speakers 8 SMS-NET-ML48 Sound Masking Controller 1 SMS-NET-ML24 Sound Masking Controller 3 SMS-RL96 Sound Masking Controller • Provide and install sixty (60) flush mount single locations. • Provide and install eighteen (18) flush mount single room scheduler locations. • Provide and install thirty-four (34) surface mount single camera locations. • Provide and install thirty-six (36) surface mount single wireless access point locations, these are furnished and installed by Fox Rothschild. • Provide and install three hundred (300) flush mount dual locations. • Provide and install ninety-two (92) furniture mount dual locations. • Provide and install two (2) floor mount dual locations. • Provide and install twenty-one (21) flush mount triple locations. • Provide and install nine (9) flush mount quad locations. • Provide and install twenty-one (21) table mount single locations (table to wall in conference rooms). Bluestone will provide labor to install AV vendor-provided table-top boxes. Table cuts will be by others. • Provide and install Leviton faceplates, surface mount boxes, modular jacks, couplers and connectors as required for termination of the 4-pair cables at the workstation location. • Provide and install twenty-five (25) Leviton Category 6A Angled, 110- Style 48-port patch panels. These will be installed in the new ICR for termination of the 4-pair network cables installed. • Furnish seven hundred twenty (720) Leviton Category 6A RJ45 patch cords, 5’ in length. • Furnish thirty (30) Leviton Category 6A RJ45 patch cords, 7’ in length. • Furnish twenty (20) Leviton Category 6A RJ45 patch cords, 10’ in length. • Furnish fifty (50) Leviton Category 6A RJ45 patch cords, 15’ in length. • Furnish ten

  68. PermitAddition and/or Alterations

    Permit MP-2024-001637 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  69. PermitAddition and/or Alterations

    Permit FP-2024-000740 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (8) sprinkler heads to accommodate interior alterations

  70. PermitAddition and/or Alterations

    Permit FP-2024-000741 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (94) sprinkler heads to accommodate 12th floor renovation

  71. PermitAddition and/or Alteration

    Permit EP-2024-003248 · Completed

    Furnish and install 47 lights, 11 exits, 6 duplex receptacles, 2 GFI's, 6 switches, 3 1.5 KVA Transformers, 1 exhaust fan, 1 water heater as per 2017 NEC. Install fire alarm as per drawings and 2016 NFPA 72.

  72. CertificationFire Alarm Certification

    Certification BC-2024-011014 · Certified

    Expires 2025-04-15

  73. PermitAddition and/or Alteration

    Permit EP-2024-003486 · Completed

    Install: 1334 light fixtures, 65 Exit signs, 313 switches, 616 receptacles, 25 floor receptacles, 37 furniture power, 53 equipment power, and 1 208/120 volt panel as per 2017 NEC. Fire Alarm: Install 3 NAC Panels, 116 speaker/strobes, 24 strobes, 5 smoke detectors, and 3 relays as per 2016 NFPA 72.

  74. PermitAlterations

    Permit PP-2024-003922 · Completed

    F&I (1) Water Heater, (7) LAVS, (9) Toilets, (1) Water Fountain, (2) Urinals and associated piping

  75. PermitAlterations

    Permit PP-2024-005088 · Completed

    Furnish & install new Filtered water, vent piping to office fit out space. Filtered water feeds carbonation water station. adding (2) additional pantry sinks with new domestic water piping. 3 FIXTURES.

  76. PermitAddition and/or Alteration

    Permit CP-2024-001209 · Completed

    FOR LEVEL II ALTERATIONS WITH NO CHANGE IN OCCUPANCY AT FLOORS 18 THROUGH 22. WORK AREA TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.

  77. PermitAddition and/or Alterations

    Permit FP-2024-000662 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (36) SPRINKLER HEADS ON THE 12TH FLOOR AS PER NFPA 13

  78. PermitAddition and/or Alterations

    Permit MP-2024-001090 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  79. PermitAddition and/or Alterations

    Permit MP-2024-001276 · Completed

    FOR ALTERATION TO THE EXISTING HVAC SYSTEM TO ACCOMMODATE NEW OFFICE LAYOUT AS PER APPROVED PLANS.

  80. PermitAlterations

    Permit PP-2024-003519 · Completed

    Pluming work for the Fox Rothschild fit out floors 15,16, and 17. to include 16- water closets,12- lavatories, 4- urinals, remove and replace fixture no piping change. Install 3- water closets and 3- lavatories 8- kitchen sinks and 1- floor drain, 5- water heaters with new piping.

  81. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-011507 · Certified

    Expires 2025-03-23

  82. PermitAlterations

    Permit PP-2024-004117 · Completed

    Provide labor and materials to extend from existing sanitary, vent and domestic cold water. Supply and install (2) electric water heaters and (2) kitchen sinks. 4 FIXTURES.

  83. PermitAddition and/or Alteration

    Permit CP-2024-001345 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  84. PermitAddition and/or Alterations

    Permit MP-2024-001231 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  85. PermitAddition and/or Alteration

    Permit CP-2024-000789 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 12TH FLOOR OF AN EXISTING HIGH RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  86. CertificationSmoke Control Certification

    Certification BC-2024-007065 · Certified

    Expires 2025-03-15

  87. PermitAddition and/or Alteration

    Permit EP-2024-000134 · Completed

    Furnish and install 5 duplex outlets, 1 GFI, 1 feed for hot water heater, one exhaust fans, 28 F-1 light fixtures, 8 F-2, 3, F-3 and 13 exit signs Fire Alarm as per drawings 2017 NEC,2016 NFPA-72,2018 PHILAV FIRE CODE -NOTED: NAC BOOSTER AND SMOKE DETECTOR LOCATION APPROVED-

  88. PermitAddition and/or Alteration

    Permit CP-2024-000621 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS TO ACCOMMODATE THE 15TH, 16TH AND 17TH FLOOR OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  89. PermitAddition and/or Alterations

    Permit MP-2023-005431 · Completed

    FOR THE INSTALLATION OF A NEW HVAC SYSTEM INCLUDING REGISTERS AND DIFFUSERS WITH ASSOCIATED DUCTWORK AND ACCESSORIES AS PER PLANS.

  90. PermitAlterations

    Permit PP-2023-016843 · Expired

    INSTALL 9 WATER CLOSETS, 2 URINALS, 7 LAVATORIES, 1 HOT WATER HEATER AND 1 ELECTRIC WATER COOLER ACCORDING TO THE 2018 PPC AND PER PLANS.

  91. PermitAddition and/or Alterations

    Permit FP-2023-002940 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 36 SPRINKLER HEADS

  92. PermitAddition and/or Alterations

    Permit MP-2023-005420 · Expired

    FOR ALTERATIONS TO THE EXISTING HVAC SYSTEM AT THE 15TH FLOOR TO INCLUDE THE INSTALLATION OF APPLIANCES, GRILLES / REGISTERS / DIFFUSERS, TOILET ROOM EXHAUST, AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2023-006467 FOR ASSOCIATED BUILDING PERMIT.

  93. PermitAddition and/or Alteration

    Permit EP-2023-011480 · Completed

    Demo Existing Office Space, Furnish and Install Power and Lighting Per Plans and 2017 NEC :AMENDMENT: Furnish and Install Fire Alarm per Plans. -2017 NEC,2016 NFPA-72.

  94. PermitAddition and/or Alteration

    Permit CP-2023-006467 · Expired

    FOR A LEVEL INTERIOR II ALTERATIONS TO THE EXISTING RESTROOMS AND CORRIDORS LOCATED ON THE 15TH FLOOR OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENT THROUGHOUT. BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**

  95. PermitAddition and/or Alterations

    Permit FP-2023-002826 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (24) SPRINKLER HEADS AS PER NFPA 13

  96. CertificationSpecial Hazards Certification

    Certification BC-2023-023734 · Certified

    Expires 2024-11-20

  97. CertificationSprinkler Certification

    Certification BC-2024-008135 · Certified

    Expires 2024-11-14

  98. PermitAddition and/or Alteration

    Permit CP-2023-006226 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE (SUITE 520) ON THE FIFTH FLOOR OF AN EXISTING HIGH RISE OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  99. PermitAddition and/or Alterations

    Permit MP-2023-003474 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating 5 diffusers in the 10th floor core restrooms

  100. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2023-007749 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  101. PermitAddition and/or Alteration

    Permit EP-2023-007662 · Completed

    Removing light fixture to be reused in same place AS PER NEC 2017

  102. PermitAlterations

    Permit PP-2023-011360 · Completed

    Remove and replace plumbing fixtures with new fixtures, (6) lavatories, (8) water closets and (2) urinals, connecting to existing piping. **NO PIPING**

  103. CertificationFire Alarm Certification

    Certification BC-2023-016665 · Certified

    Expires 2024-08-07

  104. PermitAddition and/or Alterations

    Permit FP-2023-001827 · Completed

    Relocate (6) sprinklers to accommodate interior alterations, 10th floor restrooms

  105. PermitAlterations

    Permit PP-2023-010166 · Completed

    REPLACE 16 FIXTURES **WITHOUT PIPING**

  106. PermitAddition and/or Alteration

    Permit EP-2023-006936 · Completed

    Furnish and install one floor box, one outlet, 75 1x5 light fixtures . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**

  107. PermitAddition and/or Alteration

    Permit EP-2023-006969 · Completed

    Replace existing light fixtures & switches with new inside Restrooms as per 2017 nec

  108. PermitAddition and/or Alteration

    Permit CP-2023-004069 · Completed

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING TOILET ROOMS ON THE 5TH FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  109. PermitAddition and/or Alteration

    Permit CP-2023-003893 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO THE 10TH FLOOR OF AN EXISTING STRUCTURE. ALTERATIONS TO REST ROOMS, ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. THE BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. **

  110. PermitAddition and/or Alteration

    Permit CP-2023-003763 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO THE 5TH FLOOR OF AN EXISTING STRUCTURE ALTERATIONS TO INCLUDE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. THE BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. **

  111. PermitAddition and/or Alteration

    Permit EP-2023-003114 · Completed

    Security system consisting of installing cable for (2) head end panels, terminate access cables furnished and installed by other to JCI panel, (19) door contacts, (1) REX, (18) Card readers, (9) Sounders, (4) TS-17, (2) hold up buttons, (2) turnstiles, (14) IP cameras and Intercom/3 stations as per 2017 nec

  112. PermitAddition and/or Alterations

    Permit MP-2023-001861 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  113. PermitAddition and/or Alteration

    Permit EP-2023-004860 · Completed

    Install (174) Category 6 plenum cables & (48) Category 6a plenum cables from the appropriate MDF to the customer indicated workstation locations per floor plan to be provided. Install (2) 2-post racks, with requisite ladder lack and wall supports, to customer indicated location within the MDF Install (1) 4-post cabinet, with requisite ladder lack and wall supports, to customer indicated location within the MDF Install (1) 6-strand SM fiber & (2) Category 6 cables from the MDF to the 10th floor riser closet for the extension of client services Install (22) Category 6 plenum cables & (4) RG6 plenum coax cables from the appropriate MDF/IDF (#1009 or #1010) to the customer indicated workstation locations per floor plan to be provided. Install (1) RG6 plenum coax from the IDF #1009 to the 10th floor riser closet for the extension of client services. Install (1) 4-post cabinet, with requisite ladder lack and wall supports, to customer indicated location within the MDF. Install (14) Category 6 plenum cables from the appropriate MDF/IDF (#1009 or #1010) to the customer indicated IP Camera locations per floor plan to be provided Install and label (22) OSDP Composite Cables. All material is to customer provided. Cables to be terminated/connected by security vendor and devices will be installed by the security vendor. Install and label (10) 18/2 Cables. All material is to customer provided. Cables to be terminated/connected by security vendor and devices will be installed by the security vendor. Install and label (3) 18/2 Cables. All material is to customer provided. Cables to be terminated/connected by security vendor and devices will be installed by the security vendor. As per 2017 nec

  114. CertificationSpecial Hazards Certification

    Certification BC-2023-010750 · Certified

    Expires 2024-05-18

  115. PermitAddition and/or Alterations

    Permit MP-2023-001185 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK FOR A BUSINESS OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  116. PermitAddition and/or Alterations

    Permit MP-2023-000649 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  117. PermitAddition and/or Alteration

    Permit EP-2023-003917 · Completed

    Install new light fixtures and receptacles utilizing existing panels as per drawings-2017 NEC. AMENDMENT: Install fire alarm per APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  118. InvestigationL&I investigation

    Case CF-2022-050850 · PASSED

    The cited inspection visit was marked passed.

  119. PermitAlterations

    Permit PP-2023-005515 · Completed

    INSTALL 8 WATER CLOSETS, 2 URINALS, 2 ELECTRIC WATER COOLERS, 7 LAVATORIES AND 1 HOT WATER HEATER ACCORDING TO THE 2018 PPC AND PER PLANS.

  120. PermitAddition and/or Alterations

    Permit FP-2023-000932 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (3) sprinkler heads on 26th floor, in common corridor

  121. PermitAddition and/or Alteration

    Permit EP-2023-003145 · Completed

    Install new panel, receptacles, poke-thrus, lights & light controls . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  122. PermitAddition and/or Alteration

    Permit CP-2023-001968 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO THE 26TH FLOOR OF AN EXISTING STRUCTURE ALTERATIONS TO INCLUDE THE ADDITION OF AN ADA TOILET ROOM, ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. THE BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. **

  123. PermitAddition and/or Alteration

    Permit EP-2023-003148 · Completed

    Install fire alarm devices as per drawings as per 2016 NFPA 72.

  124. CertificationFire Alarm Certification

    Certification BC-2023-008360 · Certified

    Expires 2024-04-14

  125. PermitAlterations

    Permit PP-2023-004483 · Completed

    Remove and replace plumbing fixtures with new, (1) lavatory, (1) water closet, (1) electric hot water heater and (2) drinking fountains, connecting to existing piping.

  126. PermitAddition and/or Alterations

    Permit MP-2023-001252 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  127. PermitAddition and/or Alterations

    Permit FP-2023-000730 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (23) sprinkler heads to accommodate 10th floor interior alteration (CP-2023-001413)

  128. PermitAddition and/or Alteration

    Permit EP-2023-002776 · Completed

    33 Lighting fixtures 6 Switches 1 Power supply @ 120 volts for Security 3 GFI non dedicated 6 Duplex receptacles 1 Exhaust fans to wire and connect 1 Water heater to wire and connect 1 FPV #10-33 To relocate 1 FPV #10-34 To wire and connect 1 Wire and connect to existing panelboards 1 Smoke detectors 1 Strobe 9 Speaker/strobe 1 Door release relay to wire and connect 1 Parts & Smarts & Recertification ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  129. PermitAddition and/or Alteration

    Permit EP-2023-001094 · Completed

    Install lighting and branch circuit wiring as per 2017 NEC. Install new fire alarm devices on existing system as per 2016 NFPA 72.

  130. InvestigationL&I investigation

    Case CF-2023-012491 · PASSED

    The cited inspection visit was marked passed.

  131. PermitAddition and/or Alteration

    Permit CP-2023-001413 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO THE 10TH FLOOR OF AN EXISTING STRUCTURE ALTERATIONS TO INCLUDE THE ADDITION OF AN ADA TOILET ROOM, ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**

  132. PermitAddition and/or Alterations

    Permit FP-2023-000611 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating (155) sprinkler heads on 10th floor - Accenture

  133. PermitAddition and/or Alterations

    Permit MP-2023-000823 · Expired

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.**WORK TO ACCOMMODATE THE 35TH AND 36TH FLOOR OF AN EXISTING STRUCTURE **ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.**

  134. PermitAlterations

    Permit PP-2023-002991 · Completed

    INSTALL 8 SUPPLY OUTLET BOXES, 2 HOT WATER HEATERS, 1 WATER CLOSET, 1 LAVATORY, 2 BACKFLOW PREVENTERS, 3 KITCHEN SINKS, 2 HUB DRAINS AND 3 FLOOR DRAINS ACCORDING TO THE 2018 PPC.

  135. PermitAddition and/or Alteration

    Permit EP-2023-002169 · Completed

    Low Voltage Computer wiring per NEC 2017

  136. PermitAlterations

    Permit PP-2023-003037 · Expired

    Install supply and DWV pipe for the listed fixtures per the 2018 Philadelphia Plumbing Code.

  137. PermitAddition and/or Alteration

    Permit EP-2023-001610 · Completed

    Install new fire alarm devices and wiring and connect to existing system as per 2016 NFPA 72.

  138. PermitAddition and/or Alteration

    Permit EP-2023-001449 · Completed

    Rework and Reuse existing panels. Install new lights, receptacles and devices. Power connections to HVAC/Mech equipment. Empty box and stub up for telecom, AV and Security as per 2017 nec. **SEPARATE FIRE ALARM PERMIT REQ'D**

  139. PermitRough-In

    Permit EP-2023-001450 · Expired

    Rough-In Permit for EP-2023-001449 Rework and Reuse existing panels. Install new lights, receptacles and devices. Power connections to HVAC/Mech equipment. Empty box and stub up for telecom, AV and Security as per 2017 nec

  140. ViolationFACADES

    Case CF-2023-012491 · Violation VI-2023-009633 · Code PM15-315.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  141. InvestigationL&I investigation

    Case CF-2023-012491 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  142. PermitAddition and/or Alteration

    Permit CP-2023-000452 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 10TH FLOOR LEVEL FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INLCUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. STRUCTURAL WORK TO BE COMPLETED AS SHOWN PER PLANS. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  143. PermitAddition and/or Alterations

    Permit FP-2023-000297 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. (CP-2023-000455) Relocate (56) Sprinkler Heads on the 26th floor.

  144. PermitAlterations

    Permit PP-2023-001597 · Completed

    F&I (1) New Sink, (10) Gal Water Heater utilizing existing rough in

  145. PermitAddition and/or Alteration

    Permit CP-2023-000455 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING OFFICE SPACE ON THE 26TH FLOOR OF AN EXISTING HIGH RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  146. PermitAddition and/or Alterations

    Permit FP-2023-000058 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. (CP-2022-007359) Relocate (15) Sprinkler Heads on the 35th floor as per NFPA 13

  147. PermitAddition and/or Alteration

    Permit CP-2022-007359 · Expired

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO OFFICE SPACES ON THE 35TH AND 36TH FLOORS OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  148. PermitAlterations

    Permit PP-2022-017687 · Completed

    Remove and replace existing fixtures with new, (1) kitchen sink and (1) water heater, connecting to existing piping.

  149. PermitAddition and/or Alteration

    Permit EP-2022-009989 · Completed

    Furnish and Install Lighting, Power, ,fire alarm and Distribution Requirements . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  150. PermitAlterations

    Permit PP-2022-017354 · Completed

    Remove and replace existing plumbing fixtures with new, (2) kitchen sinks and (2) electric water heaters, connecting to existing piping.

  151. PermitAddition and/or Alteration

    Permit EP-2022-012109 · Completed

    Furnish & install (153) Cat 6 plenum cables for voice/data Furnish & install access control cabling/components at (4) door locations as per 2017 nec

  152. PermitAddition and/or Alteration

    Permit EP-2022-011971 · Completed

    Furnish & install (62) Category 6 plenum cables from the Server Room to the customer indicated workstation. Furnish & install (1) 4-post rack (45U x 29” D. Furnish & install (2) Category 6, rack mounted, 48-port patch panels for the termination of Category 6 cabling within Server Room as per 2017 nec

  153. PermitAddition and/or Alteration

    Permit EP-2022-011597 · Completed

    116 Lighting fixtures 041 Switches 026 Box & string for data lines by others 005 Furniture system feeds 072 Receptacles 007 Fire rated floor receptacles 001 Water heater to wire and connect 001 Dishwasher to wire and connect 013 HVAC Units to wire and connect 001 Pump to wire and connect 002 New panelboards 002 Kwh meters 017 Fire alarm devices 001 Test and recertify fire alarm system As per APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018PHILA FIRE CODE.

  154. PermitAddition and/or Alterations

    Permit MP-2022-005902 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  155. PermitRough-In

    Permit EP-2022-011599 · Expired

    Rough-In Permit for EP-2022-011597 116 Lighting fixtures 041 Switches 026 Box & string for data lines by others 005 Furniture system feeds 072 Receptacles 006 Fire rated floor receptacles 001 Water heater to wire and connect 001 Dishwasher to wire and connect 013 HVAC Units to wire and connect 001 Pump to wire and connect 002 New panelboards 002 Kwh meters 017 Fire alarm devices 001 Test and recertify fire alarm system As per 2017 nec and nfpa 72

  156. PermitAddition and/or Alterations

    Permit FP-2022-002955 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. *CP-2022-005968* Relocate (63) Sprinkler Heads on the 9th fl.

  157. CertificationSpecial Hazards Certification

    Certification BC-2022-015957 · Certified

    Expires 2023-11-01

  158. PermitAddition and/or Alteration

    Permit CP-2022-005968 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS AT THE 9TH FLOOR OF THE EXISTING HIGH-RISE BUILDING. PARTIAL DEMO AND ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES, AND FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK.

  159. PermitAddition and/or Alterations

    Permit MP-2022-005042 · Completed

    FOR THE INSTALLATION/ALTERATION OF DUCTWORK AND REGISTERS/DIFFUSERS FOR NEW OFFICE LAYOUT PER APPROVED PLANS.

  160. PermitAddition and/or Alterations

    Permit FP-2022-002660 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (32) SPRINKLER HEADS AS PER NFPA 13

  161. PermitAddition and/or Alteration

    Permit CP-2022-005366 · Completed

    FOR A LEVEL II INTERIOR ALTERATION TO THE 11TH FLOOR LEVEL OF AN EXISTING STRUCTURE. FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  162. InvestigationL&I investigation

    Case CF-2022-050850 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  163. InvestigationL&I investigation

    Case CF-2022-050850 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  164. PermitAddition and/or Alterations

    Permit FP-2022-001825 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans.

  165. PermitAlterations

    Permit PP-2022-008135 · Completed

    • Furnish and install [4] Supply Outlet Boxes for Owner Supplied Water Dispensers. • Provide labor and material to make final connection to [4] water dispensers. - We are only installing 1/2" copper water lines from existing mains in ceiling to new water dispensers AS PER PPC 2018

  166. PermitAddition and/or Alterations

    Permit MP-2022-003048 · Completed

    FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE VAV BOX, DEMOLITION AND RELOCATION OF DIFFUSERS/REGISTERS/GRILLES, AND ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT THE DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS ARE REQUIRED FOR ALL OTHER WORK.

  167. License terminal eventPHILADELPHIA PLAZA PHASE II: High Rise L&I license filing marked inactive

    License 299017 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  168. PermitAddition and/or Alteration

    Permit EP-2022-005547 · Completed

    Relocate six fixtures, install one new 2x4 fixture and relocate eight wall switches. Install new receptacles utilizing existing circuits. All existing panels to remain. Tele/data raceways 2017 NEC. Install fire alarm with plenum rated cabling as per drawings and 2016 NFPA 72.

  169. ViolationSUBMISSION OF DEFICIENCIES

    Case CF-2022-050850 · Violation VI-2022-037797 · Code F-901.6.4.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  170. ViolationCOMMERCIAL SYSTEM TEST

    Case CF-2022-050850 · Violation VI-2022-037815 · Code F-904.12.5.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  171. ViolationFAIL OBTAIN LICENSE (Obtain the license identified in the notice)

    Case CF-2022-050850 · Violation VI-2022-037809 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  172. InvestigationL&I investigation

    Case CF-2022-050850 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  173. PermitAddition and/or Alterations

    Permit FP-2022-001452 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Modifying (7) Sprinklers on the 23rd floor

  174. PermitAddition and/or Alteration

    Permit CP-2022-002569 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY ). WORK TO BE LIMITED TO THE 23RD FLOOR OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE INSTALLATION OF NEW WALL PARTITIONS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT AS PER APPROVED PLANS. ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK**IEBC 2018**EXISTING BUILDING IS FULLY SPRINKLERED** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**

  175. PermitNew Construction

    Permit EP-2022-004470 · Completed

    Provide and install (1) Cat 6 for data from the IDF to each of 29 locations. ? Provide and install (2) Cat 6 for data from the IDF to each of 5 locations. ? Provide and install (1) Cat 6 for wireless access points from the IDF to each of 10 ceiling locations. ? Provide and install (49) 1’ Cat 6 patch cables and (49) 10’ Cat 6 patch cables. ? Provide and install (1) 2-post rack and (2) 6” vertical wire managers in the IDF. ? Provide and install (1) 12” ladder tray in the IDF above the new rack for cable routing. ? Provide and install (1) 6 strand OM3 multimode interlocking plenum fiber from the 1st floor DMarc to the 9th floor IDF. Estimate of 650’ total feet used for calculations. Fiber pathway length and accessibility will need to be field verified prior to ordering the fiber. ? Update existing customer provided CAD as-built drawings identifying all drop locations as installed. As per 2017 nec

  176. CertificationSpecial Hazards Certification

    Certification BC-2022-006729 · Certified

    Expires 2023-05-04

  177. CertificationSpecial Hazards Certification

    Certification BC-2022-005460 · Deficient

  178. PermitAddition and/or Alterations

    Permit FP-2022-000368 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (155) Sprinkler Heads on the 9th fl. (CP-2022-000330)

  179. PermitAddition and/or Alteration

    Permit CP-2022-000326 · Completed

    FOR LEVEL II ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS AROUND EXISTING STAIR ENCLOSURE FROM THE 9TH TO THE 10TH FLOOR LEVEL. WORK TO INCLUDE FINISHES AND FURNISHINGS AS SHOWN PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  180. PermitAlterations

    Permit PP-2022-001647 · Completed

    Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018.

  181. PermitAddition and/or Alteration

    Permit EP-2022-001065 · Completed

    Furnish and Install 50 Lights, 5 Exits, Lighting controls, 3 Dimmers, Relocate 1 FPB, 4 Quads, 1 Floor Box, 5 Duplex as per 2017 NEC ELECTRIC PANELS ARE EXISTING. Re-certify existing fire alarm system as per NFPA 72

  182. License terminal eventPHILADELPHIA PLAZA-PHASE II: Hazardous Materials L&I license filing marked inactive

    License 285717 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  183. PermitAddition and/or Alteration

    Permit EP-2022-001075 · Completed

    Electrical renovation of the 9th floor of an existing office building consisting of new lighting, lighting controls, wiring devices as per 2017 NEC. Install fire alarm system as per 2016 NFPA 72.

  184. PermitAddition and/or Alteration

    Permit EP-2022-000693 · Completed

    Relocation of Existing Lighting Fixtures & Receptacles / Replacement with New (10 Lights & 5 Receptacles in Total) -- NO NEW BRANCH CIRCUITING . ALL WORK IS TO BE DONE TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM IS ON THIS PERMIT**

  185. PermitAddition and/or Alterations

    Permit MP-2022-000695 · Completed

    FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM THROUGHOUT A RENOVATED BUSINESS OFFICE OCCUPANCY TO INCLUDE THE INSTALLATION OF VAVs, REGISTERS / DIFFUSERS / GRILLES, AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2022-000330 FOR ASSOCIATED BUILDING ALTERATIONS PERMIT.

  186. PermitAddition and/or Alterations

    Permit MP-2022-000677 · Completed

    FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM THROUGHOUT A RENOVATED BUSINESS OFFICE OCCUPANCY TO INCLUDE THE RELOCATION OF TWO (2) EXISTING THERMOSTATS AND ONE (1) EXISTING VAV BOX AND THE INSTALLATION OF SIX (6) DIFFUSERS AND TWELVE (12) TRANSFER AIR SLEEVES. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2022-000301 FOR ASSOCIATED BUILDING ALTERATIONS PERMIT.

  187. PermitAddition and/or Alteration

    Permit EP-2022-001085 · Completed

    Thirty-One (31) Low Voltage Category 6 computer wiring locations as per NEC 2017

  188. PermitAlterations

    Permit PP-2022-001649 · Completed

    Disconnect [1] pantry sink Furnish and install [1] new pantry sink in same location

  189. PermitAddition and/or Alterations

    Permit FP-2022-000384 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (18) Sprinkler Heads on the 39th fl. (CP-2022-000301)

  190. PermitAddition and/or Alteration

    Permit CP-2022-000301 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A BUSINESS OCCUPANCY ON THE 39TH FLOOR LEVEL. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES, AND FURNISHINGS THROUGHOUT. BUILDING TO BE FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  191. PermitAddition and/or Alteration

    Permit CP-2022-000330 · Completed

    For Level II alterations (w/o a change of occupancy) to the Group B occupancy (Offices) on the 9th floor of an existing high-rise office building, as per plans; separate permits required for all MEP/FSP work; building is fully sprinklered throughout in accordance with NFPA 13 and standpipes installed within the exit stairways in accordance with NFPA 14; includes structural work to 10th floor framing.

  192. PermitAddition and/or Alterations

    Permit MP-2022-000536 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Furnish labor and materials to RELOCATE seven air devices

  193. PermitAddition and/or Alterations

    Permit MP-2021-007980 · Expired

    FOR RELOCATION OF DIFFUSERS/REGISTERS TO ACCOMODATE NEW FLOOR LAYOUT OF AN EXISTING OFFICE AS PER EZ STANDARD.

  194. PermitAddition and/or Alterations

    Permit FP-2022-000248 · Completed

    Relocating 8 Sprinklers See CP-2021-009222

  195. PermitAddition and/or Alteration

    Permit CP-2021-009222 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE FIFTH FLOOR USE FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  196. PermitAddition and/or Alteration

    Permit EP-2021-015290 · Completed

    Installation of low voltage Category 6 computer cable per NEC 2017

  197. PermitAlterations

    Permit PP-2021-024382 · Completed

    Furnish and install WITHOUT PIPING (1) pantry sink and faucet

  198. PermitAddition and/or Alterations

    Permit FP-2021-003637 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (1) Sprinkler Head 32nd Fl (CP-2021-006165)

  199. InvestigationL&I investigation

    Case CF-2021-114926 · PASSED

    The cited inspection visit was marked passed.

  200. ViolationCOMPL CONCEAL- BLDG PERM WORK

    Case CF-2021-114926 · Violation VI-2021-083377 · Code A-402.1/1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  201. ViolationARCHITECT/ENGINEER SERVICES

    Case CF-2021-114926 · Violation VI-2021-083378 · Code A-304.1/1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  202. InvestigationL&I investigation

    Case CF-2021-114926 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  203. PermitAddition and/or Alterations

    Permit FP-2021-003364 · Completed

    Relocate (12) Sprinkler Heads in Suite 800 as per NFPA 13 See CP-2021-006165

  204. PermitAddition and/or Alteration

    Permit EP-2021-012409 · Completed

    Add receptacles to an existing space as per 2017 NEC

  205. PermitAddition and/or Alteration

    Permit EP-2021-011806 · Completed

    Installation of (5) Downlight fixtures connected to existing 277 Volt circuit as per 2017 nec

  206. PermitAddition and/or Alteration

    Permit EP-2021-011353 · Completed

    Relocate (15) lights, (7) switch, Install (6) switch, (4) exit, (2) receptacle, (12) JB power, (1) 225 amp breaker, refeed (3) 208/120 volt panel as per 2017 NEC.

  207. PermitAddition and/or Alteration

    Permit CP-2021-006165 · Completed

    FOR A LEVEL II INTERIOR ALTERATION FOR THE 32ND AND 33RD FLOOR OF AN EXISTING BUILDING. WORK SPACES AS PART OF THE BUSINESS USE OF THE STRUCTURE. ALTERATIONS TO INCLUDE THE SELECTIVE DEMOLITION OF EXISTING PARTITION, AND THE ERECTION OF NEW WALL PARTITIONS AND TO PROVIDE FINISHES AND FURNISHINGS THROUGHOUT THE DESIGNATED WORK AREAS . ALL WORK TO BE DONE PER APPROVED PLANS.**BUILDING IS FULLY SPRINKLERED**IEBC 2018** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**ANY DEVIATION TO THE APPROVED SCOPE OF WORK WILL REQUIRED AN AMENDED PERMIT**

  208. PermitAddition and/or Alterations

    Permit MP-2021-006304 · Completed

    For alterations to an existing mechanical/HVAC system within the 8th floor of an existing high-rise office building, including the relocation of four (4) thermostats, installation of six (6) new diffusers, and installation of seven (7) new air transfer ducts, as per plans; no other work on this permit; see CP-2021-005744 for associated building permit.

  209. PermitAddition and/or Alterations

    Permit FP-2021-002833 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (3) sprinkler heads on the 33rd floor (CP-2021-006691)

  210. PermitAddition and/or Alteration

    Permit CP-2021-006691 · Completed

    FOR A LEVEL II INTERIOR ALTERATION TO THE 33RD FLOOR OF AN EXISTING BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF NEW WALL PARTITIONS AND TO PROVIDE FINISHES AND FURNISHINGS THROUGHOUT . ALL WORK TO BE DONE PER APPROVED PLANS.**BUILDING IS FULLY SPRINKLERED PER NFPA 13 **IEBC 2018** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**ANY DEVIATION TO THE APPROVED SCOPE OF WORK WILL REQUIRED AN AMENDED PERMIT**

  211. PermitAddition and/or Alteration

    Permit CP-2021-005744 · Completed

    FOR A LEVEL II INTERIOR ALTERATION (NO CHANGE IN OCCUPANCY) TO AN EXISTING BUSINESS OCCUPANCY . ALTERATIONS TO INCLUDE THE ERECTION OF NEW PARTITIONS AND TO PROVIDE FINISHES AND FURNISHINGS THROUGHOUT THE DESIGNATED AREA . ALL WORK TO BE DONE PER APPROVED PLANS.**EXISTING BUILDING IS FULLY SPRINKLERED **IEBC 2018** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**ANY DEVIATION TO THE APPROVED SCOPE OF WORK WILL REQUIRED AN AMENDED PERMIT**

  212. PermitAddition and/or Alteration

    Permit EP-2021-007163 · Completed

    Johnson Controls/Tyco shall install a KT-400 Access Control system in Suite 2850. The head end, door contacts, exit buttons, and Rex motions shall be reused and retained from a remote site. New lock power supplies and card readers shall be installed as per 2017 nec

  213. PermitAddition and/or Alteration

    Permit EP-2021-006662 · Completed

    Furnish and Install (25) Category 6 cables for added workstations. Average cable pull is 150' AS PER NEC 2017

  214. PermitAlterations

    Permit PP-2021-009701 · Completed

    Relocation of plumbing fixture, (1) sink, approximately 6 feet to the left of current location.28th floor

  215. PermitAddition and/or Alteration

    Permit EP-2021-006275 · Completed

    4 Remove & reinstall wall sconces 1 Replace existing corridor receptacle with white device 10 Clean & relamp existing lighting 3 Duplex receptacles for automatic faucets 2 Remove & reinstall F/A devices in same location As per 2017 nec

  216. PermitAddition and/or Alteration

    Permit EP-2021-006080 · Expired

    Relocate existing circuits to satisfy new layout of printers. Circuit Trace as per 2017 NEC. NO INTERIOR ALTERATIONS. ONLY FISHING WIRE THROUGH EXISTING PATHWAYS. (CP IS NOT NEEDED)

  217. PermitAddition and/or Alteration

    Permit EP-2021-005619 · Completed

    Interior renovation including relocated light fixtures and two new to match existing. New 120-volt receptacles, floor receptacle, Addition fire alarm for renovated area as per APPROVED DRAWINGS 2017 nec and 2016 nfpa 72.

  218. PermitAddition and/or Alterations

    Permit MP-2021-003493 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (Add one VAV +/- 400 cfm , add 1 75 cfm exhaust fan. 28th floor).

  219. PermitAddition and/or Alteration

    Permit CP-2021-003634 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING TOILET ROOMS ON THE 11TH FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  220. PermitAddition and/or Alteration

    Permit EP-2021-005824 · Completed

    Furnish and install (18) Cat 6 cables. Average cable pull is 150 feet. AS PER NEC 2017

  221. CertificationDamper Certification

    Certification BC-2021-007000 · Certified

    Expires 2025-06-03

  222. PermitAddition and/or Alteration

    Permit EP-2021-004596 · Completed

    Renovate fire alarm system for tenant fit out as per APPROVED DRAWINGS NFPA- 72.

  223. PermitAlterations

    Permit PP-2021-007511 · Completed

    Furnish and install one water closet, one lav, one pantry sink, one water cooler and one HWH and related piping according to the 2018 PPC.

  224. PermitAddition and/or Alterations

    Permit FP-2021-001429 · Completed

    relocate (2) sprinkler heads on the 28th floor

  225. PermitAddition and/or Alteration

    Permit EP-2021-004508 · Completed

    Renovation to existing space: install (184) light fixtures, (8) exits, (18) occupancy switch as per drawings as per 2017 nec

  226. PermitAddition and/or Alteration

    Permit CP-2021-002727 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING BUILDING FOR USE AS A BUSINES/PROFESSIONAL OFFICE, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS ARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  227. PermitAddition and/or Alterations

    Permit MP-2021-002900 · Completed

    For the installation of mechanical work to include registers/diffusers and ductwork as per apprved plans.

  228. PermitAddition and/or Alteration

    Permit EP-2021-004343 · Completed

    Interior renovation, relocate existing lighting and add new LED Lighting. New 120-volt receptacles. ALL WORK IS TO BE DONE ACCORDING TO THE APPROVED DRAWINGS-2017 NEC.** NO FIRE ALARM ON THIS PERMIT -A SEPARATE FIRE ALARM PERMIT IS REQUIRED**

  229. PermitAddition and/or Alterations

    Permit FP-2021-001201 · Completed

    Relocate (20) sprinkler heads on the 20th floor

  230. PermitAddition and/or Alteration

    Permit CP-2021-002406 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) TO THE 29TH FLOOR OF AN EXISTING STRUCTURE AS PER APPROVED PLANS**EXISTING BUILDING ISFULLY SPRINKLERED **IEBC 2018** SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**

  231. PermitAlterations

    Permit PP-2021-006863 · Completed

    Remove and replace existing plumbing fixtures with new fixtures. Fixtures to include, 2 pantry sinks, 1 water closet and 1 lavatory.

  232. PermitAddition and/or Alterations

    Permit FP-2021-001172 · Expired

    Relocate 341 sprinkler heads on the 12th, 14th & 15th floors in accordance with EZ Standard. No associated alterations.

  233. PermitAddition and/or Alteration

    Permit EP-2021-003288 · Completed

    6 Relocate existing receptacles 2 Install new receptacles 3 Relocate existing lighting fixtures 2 Relocate light switches As per 2017 nec

  234. PermitAddition and/or Alterations

    Permit MP-2021-001864 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation if New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. (Furnish labor and material to relocate 5 diffusers for new office layout).

  235. PermitAddition and/or Alterations

    Permit FP-2021-001080 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (19) sprinkler heads on the 16th floor (CP-2021-001705)

  236. PermitAddition and/or Alteration

    Permit CP-2021-001705 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR THE CREATION OF A SHELL OFFICE SPACE TO INCLUDE REPLACEMENT OF FLOORING AND CEILING ON THE 16TH FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  237. PermitAddition and/or Alterations

    Permit MP-2021-001566 · Completed

    FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE VAV BOX, AIR DEVISES, DIFFUSERS/REGISTERS/GRILLES, AND ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  238. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2021-003183 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  239. PermitAddition and/or Alteration

    Permit CP-2021-001502 · Completed

    INTERIOR ALTERATION (LEVEL II) TO PART OF 39TH FLOOR OF AN EXISTING STRUCTURE (SIZE AND LOCATION AS SHOWN ON PLAN/APPLICATION). KEEP THE EXISTING USE AS A BUSINESS AND PROFESSIONAL OFFICE

  240. PermitAddition and/or Alterations

    Permit FP-2021-000941 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (226) SPRINKLER HEADS ON THE 9TH & 10TH FLOORS (CP-2021-00948)

  241. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2021-002710 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  242. PermitAddition and/or Alteration

    Permit EP-2021-002362 · Completed

    Electrical demolition of all wiring on the 9th, 10th, & 11th Floors. Electrical wiring for a tenant fit-out project on the 11th Floor. 316 Lighting fixtures 049 Lighting controls 102 Receptacles 020 Furniture system feeds 013 Relocate HVAC feeds 003 Water heater connections 001 Exhaust fan connection 046 Fire Alarm speaker/strobe devices As per 2017 nec and nfpa 72

  243. PermitAddition and/or Alterations

    Permit FP-2021-000667 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (136) sprinkler heads on the 11th floor as per NFPA 13 (CP-2021-000948)

  244. PermitAddition and/or Alteration

    Permit CP-2021-000948 · Completed

    FOR A LEVEL II INTERIOR ALTERATION TO AN EXISTING GROUP B OCCUPANCY (WITHOUT A CHANGE OF OCCUPANCY) ON THE 9TH,10TH AND 11TH FLOORS OF AN EXISTING HIGH-RISE OFFICE BUILDING, AS PER PLANS**IEBC 2018****BUILDING IS FULLY SPRINKLERED THROUGHOUT**SEPARATE PERMITS REQUIRED FOR ALL MECHANCAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK**

  245. PermitAddition and/or Alteration

    Permit EP-2021-001010 · Completed

    Installation of a Software House Access Control System. A new access control panel, power supply and lock power supply shall be installed. Existing card readers shall be replaced and the rest of the door hardware and existing cable shall be used for the Access Control System as per 2017 nec

  246. InvestigationL&I investigation

    Case CF-2020-066813 · PASSED

    The cited inspection visit was marked passed.

  247. PermitAddition and/or Alteration

    Permit EP-2020-009321 · Completed

    Fire Alarm Device Replacement on the 40th Floor 10 Speaker / Strobes Ceiling -2 Wall Speaker / Strobes - NAC panel - 1 Smoke Detector - 1 Relay as per 2016 NFPA 72.

  248. PermitAddition and/or Alteration

    Permit EP-2020-006814 · Completed

    Re-install existing speaker/strobes and Installation of 7 new ceiling speaker strobes and nac panel as per the 2017 nec & 2016 nfpa72.

  249. PermitAddition and/or Alterations

    Permit FP-2020-001759 · Completed

    We will be relocating (35) sprinklers at McCormick and Priore, 38th floor.

  250. InvestigationL&I investigation

    Case CF-2020-066813 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  251. ViolationFIREBLOCKING/DRAFTSTOPPING

    Case CF-2020-066813 · Violation VI-2020-038000 · Code FC-13-703.1.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  252. ViolationSTORAGE IN BUILDINGS

    Case CF-2020-066813 · Violation VI-2020-037999 · Code FC-13-315.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  253. ViolationFIRE SYSTEMS MAINTAINED

    Case CF-2020-066813 · Violation VI-2020-038001 · Code FC-13-901.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  254. ViolationCEILING CLEARANCE

    Case CF-2020-066813 · Violation VI-2020-037998 · Code FC-13-315.2.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  255. ViolationSMOKE BARRIERS/PARTITIONS

    Case CF-2020-066813 · Violation VI-2020-037997 · Code FC-13-703.1.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  256. ViolationFIRE SYSTEMS MAINTAINED

    Case CF-2020-066813 · Violation VI-2020-037996 · Code FC-13-901.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  257. ViolationOPEN JUNCTION BOXES

    Case CF-2020-066813 · Violation VI-2020-038004 · Code FC-13-605.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  258. ViolationNFPA 704 SIGNS

    Case CF-2020-066813 · Violation VI-2020-038002 · Code FC-13-2703.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  259. ViolationEXTENSION CORDS

    Case CF-2020-066813 · Violation VI-2020-038003 · Code FC-13-605.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  260. PermitAddition and/or Alteration

    Permit EP-2020-003682 · Completed

    Install 263 Fixtures - 9 Exit signs - 46 Switches - 10 Poke Thurs - 172 Receptacles - 12 VAV's . All work to be done to 2017 NEC. **NO FIRE ALARM ON THIS PERMIT**

  261. PermitAddition and/or Alterations

    Permit MP-2020-002828 · Completed

    Furnish and install new diffusers , return air grilles,and ductwork and relocate existing thermostat as per plans. Provide air balance report

  262. PermitAddition and/or Alteration

    Permit EP-2020-005792 · Completed

    Furnish and Install 64 Low Voltage Category 6 computer wire locations per 2017 NEC

  263. PermitAddition and/or Alteration

    Permit EP-2020-003533 · Completed

    Supply & install new light fixtures, exit signs, duplex receptacles, and light switches as per plans. Replace existing light switches with new rocker switches in existing offices. Reuse existing electrical panels & circuits as required per plans and as per 2017 NEC.

  264. PermitAddition and/or Alteration

    Permit EP-2020-002774 · Completed

    268 Fixture - 9 Exits - 45 Switches - 140 Outlets - 12 VAV's . ALL WORK TO BE DONE ACCORDING TO THE 2107 NEC.

  265. PermitAddition and/or Alteration

    Permit EP-2020-003485 · Completed

    04 - Relocate lighting 06 - Downlights 01 - Linear pendant fixture 02 - Exit lights 11 - Switches 15 - Receptacles 06 - Furniture system feeds as per 2017 NEC

  266. PermitAddition and/or Alterations

    Permit FP-2020-000910 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, Relocating (8) sprinkler heads to accommodate renovations.

  267. PermitAlterations

    Permit PP-2020-005386 · Completed

    Furnish and install sanitary, sanitary vent and domestic water pipe. Furnish and install 2 pantry sinks and 1 electric hot water heater. as per 2018 ppc

  268. PermitAlterations

    Permit PP-2020-004414 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  269. PermitAddition and/or Alterations

    Permit MP-2020-001812 · Expired

    For Mechanical Work of Existing Commercial Space (5th floor) to include RELOCATING [6] DIFFUSERS AND RELOCATING THERMOSTATS per attached standards (No penetration of fire rated assemblies). Deviations from these standards require submission of construction and site plans.

  270. PermitRough-In

    Permit EP-2020-004035 · Completed

    Rough-In Permit for EP-2020-003485 04 - Relocate lighting 06 - Downlights 01 - Linear pendant fixture 02 - Exit lights 11 - Switches 15 - Receptacles 06 - Furniture system feeds

  271. PermitAddition and/or Alteration

    Permit CP-2020-001392 · Completed

    For prescriptive alterations to an existing Group B occupancy (without a change of occupancy) on the 5th floor of an existing high-rise office building, as per plans; separate permits required for all MEP/FSP work; building is fully sprinklered throughout; no work to common/core areas on floor or to other tenants.

  272. PermitAddition and/or Alterations

    Permit MP-2020-001297 · Completed

    For the installation of a new HVAC system including 9 new VAV boxes, duct and 1 supplemental A/C unit. Relocate 5 VAV boxes for new office layout as per plans.

  273. PermitAddition and/or Alteration

    Permit EP-2020-003078 · Completed

    Furnish & Install (140) Category 6 Plenum Cables for Voice / Data as per 2017 nec

  274. PermitAddition and/or Alterations

    Permit FP-2020-000616 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads (121 at Cooke & Bieler, 40th floor) as per attached standards. Deviations from these standards require submission of construction and site plans.

  275. PermitAlterations

    Permit PP-2020-002153 · Completed

    To furnish and install [1] sink, [1] water heater and [1] open site drain as per 2018 Philadelphia Plumbing Code.

  276. PermitAddition and/or Alteration

    Permit CP-2020-001399 · Completed

    FOR LEVEL II ALTERATIONS AT THE 40TH FLOOR TO INCLUDE PARTITIONS, DOORS, FIXTURES, FURNISHINGS, FINISHES, MILLWORK AS PER APPROVED PLANS. NO STRUCTURAL WORK THIS PERMIT **SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPRESSION WORK.** **IEBC 2018**

  277. License terminal eventCOMMERCE DU JOUR CORP: Food Manufacturer / Wholesaler business license marked inactive

    License 807631 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  278. PermitAddition and/or Alteration

    Permit EP-2020-001801 · Completed

    1 - Relocate lighting 2 - New LED 2x2's 8 - Receptacles Installation to comply with 2017 NEC.

  279. PermitAddition and/or Alteration

    Permit CP-2020-000581 · Completed

    For prescriptive alterations to an existing Group B occupancy (without a change of occupancy) on the 38th floor of an existing high-rise office building, as per plans; separate permits required for all MEP/FSP work; building is fully sprinklered throughout; no work to common/core areas on floor or to other tenants.

  280. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2020-001308 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  281. PermitAddition and/or Alteration

    Permit 1054348 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING OFFICE SPACE ON THE 30TH FLOOR LEVEL OF AN EXISTING BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.

  282. PermitElectrical

    Permit 1012669 · COMPLETED

    INSTALL 60 RECEPTACLES, INSTALL 140 LIGHTS, INSTALL 12 SWITCHES AND DIMMING CONTROLS FIRE ALARM 8 SMOKE DETECTORS, 12 STROBES, 8 DATA DROPS, 11 VAVS AS PER 2017 NEC AND NFPA 72 (CC DIST)

  283. PermitPlumbing

    Permit 1013778 · COMPLETED

    FURNISH AND INSTALL 1-KITCHEN SINK,1-FLOOR DRAIN,1-OPEN SITE DRAIN,EXTEND FROM EXISTING SANITARY,VENT AND DOMESTIC COLD WATER.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004 - THE INSTALLATION DOES NOT INCLUDE GARBAGE DISPOSAL OR DISHWASHER

  284. PermitSuppression

    Permit 1014118 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)-RELOCATE 68 SPRINKLER HEADS OF AN EXISTING SYSTEM FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  285. PermitMechanical

    Permit 1005241 · COMPLETED

    PARTIAL DEMOLITION OF EXISTING DUCTWORK AND MECHANICAL PIPING PER PLANS; INSTALLATION OF NEW DUCTWORK, GRILLES, REGISTERS, DIFFUSERS, ASSOCIATED PIPING AND OTHER EQUIPMENT / DEVICES PER PLANS .TO ACCOMMODATE THE 5TH FLOOR OF AN EXISTING HIGH-RISE BUILDING.** ALL WORK TO BE PERFORM SAS PER APPROVED PLANS**SEPARATE PERMITS REQUIRED FOR ALL ELECTRICAL AND PLUMBING WORK**

  286. PermitMajor alteration

    Permit 1004680 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS(NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION) TO SUITE# 530 OF AN EXISTING BUILDING AS PER APPROVED PLANS. **IEBC 2018**EXISTING BUILDING FULLY SPRINKLERED**SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK**

  287. PermitDemolition

    Permit 1000734 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. . STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS.

  288. CertificationFacade Report

    Certification BC-2023-006393 · Safe with Repair

    Expires 2024-08-05

  289. PermitNew Construction

    Permit 985673 · Issued

    INSTALL (40)SPEAKER STROBES (10) STROBES ONLY (2) SMOKE DETECTOR (2) MODULES (2)NAC PANEL.AS PER NFPA 72(CC DISTRICT)

  290. PermitNew Construction

    Permit 992290 · Expired

    RELOCA22 EXISTING SPRINKLER HEADS ON THE 5TH FLOOR TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES.

  291. PermitPlumbing

    Permit 976528 · COMPLETED

    FURNISH & INSTALL SANITARY, SANITARY VENT & DOMESTIC WATER PIPE TO NEW PLUMBING FIXTURES, F&I 5-PANTRY SINKS, 2-WATER CLOSETS, 2-LAVS & 5-IDW & EWH THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  292. PermitElectrical

    Permit 974966 · COMPLETED

    INSTALL 423-FIXTURES 86-SWITCHES, 24-VAV WIRING, A/VBACK BOXES & RACEWAY, SECURITY BACK BOXES, 18-FURNITURE FEEDS, 18-POKE THRU, 28-EXITS SIGNS & SHADE POER & SWITCHING AS PER NEC 2017 CC DISTRICT

  293. PermitSuppression

    Permit 977307 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  294. PermitMechanical

    Permit 974738 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUTS ON THE 26TH AND 27TH FLOORS OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER APPROVED PLANS.

  295. PermitMajor alteration

    Permit 965231 · COMPLETED

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  296. License issue eventCOMMERCE DU JOUR CORP: Food Manufacturer / Wholesaler business license initially issued

    License 807631 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  297. PermitDemolition

    Permit 960347 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. . STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS

  298. PermitSuppression

    Permit 952705 · COMPLETED

    RELOCATE 24 EXISTING SPRINKLER HEADS ON THE 5TH FLOOR TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES.

  299. PermitElectrical

    Permit 935606 · COMPLETED

    INSTALL FIRE ALARM DEVICES AS PER NFPA 72

  300. PermitElectrical

    Permit 934933 · COMPLETED

    INSTALL SPEAKER/STROBES, STROBES AND NAC PANEL AS PER PLANS AND SPECS AND IN ACCORDANCE WITH NFPA 70.

  301. PermitElectrical

    Permit 936154 · COMPLETED

    FURNISH AND INSTALL 68-CATEGORY 6 PLENUM CABLES. AVERAGE CABLE PULL 120' AS PER NEC 2008 CC DISTRICT

  302. PermitMechanical

    Permit 932256 · COMPLETED

    INSTALLATION OF HVAC INCLUDING NEW DUCTWORK TO ACCOMODATE LAYOUT AS PER PLAN.

  303. PermitElectrical

    Permit 931089 · COMPLETED

    INSTALL DUPLEX RECEPTACLES, FURNITURE FEEDS, LIGHT FIXTURES, & LIGHTING CONTROLS AS PER PLANS & SPECS AND IN ACCORDANCE WITH NEC 2008.

  304. PermitElectrical

    Permit 932555 · COMPLETED

    INSTALLING 37 C5 C CABLE BUS

  305. PermitPlumbing

    Permit 932328 · COMPLETED

    28TH FLOOR NEW BREAKROOM SINK AND ELECTRIC WATER HEATER

  306. PermitMechanical

    Permit 931780 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. FOR THE RELOCATION OF TWENTY FIVE (25) DIFFUSERS.

  307. PermitElectrical

    Permit 922930 · COMPLETED

    INSTALL FIXTURES, RECEPTACLES & SWITCHES USING EXISTING 100A & 225A PANEL AS PER NEC 2008 CC DISTRICT AND FACP AND 16-SPEAKER STROBES AS PER NFPA 72

  308. PermitSuppression

    Permit 931256 · COMPLETED

    RELOCATE 24 EXISITING SPRINKLER HEADS (COMMERCIAL)

  309. PermitMechanical

    Permit 929342 · COMPLETED

    FOR MECHANICAL ALTERATIONS ON THE 38TH FLOOR OF AN EXISTING BUILDING TO INLCUDE NEW REGISTERS/DIFFUSERS WITH ASSOCIATED DUCTWORK, AS PER APPROVED PLANS.

  310. PermitPlumbing

    Permit 929753 · COMPLETED

    INSTALL PANTRY SINK, OPEN SITE DRAIN, 6- GALLON WATER HEATER.. CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC COLD WATER

  311. PermitPlumbing

    Permit 929754 · COMPLETED

    INSTALL PANTRY SINK, OPEN SITE DRAIN, 6- GALLON WATER HEATER.. CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC COLD WATER

  312. PermitMajor alteration

    Permit 927817 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR THE USE OF A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS NEED TO BE OBTAINED FOR ALL OTHER WORK.

  313. PermitElectrical

    Permit 927763 · COMPLETED

    RENOVATION TO EXISITNG SPACE. INSTALL (55) LIGHT FIXTURES (7) LIGHT SWITCH, (26) RECEPTACLES, (6) FURNITURE POWER AS PER DRAWINGS.AS PER 2008 NEC. (CC DISTRICT)

  314. PermitElectrical

    Permit 920444 · COMPLETED

    130 CAT6 & 6A DROP LOCATIONS & BUILD 2-IDFS ON 2ND FLOOR ALL HARDWIRED & INSTALL 12-STRAND FIBER BETWEEN IDFS AS PER NEC 2008 CC DISTRICT

  315. PermitMajor alteration

    Permit 921695 · COMPLETED

    RENOVATE OFFICE SPACE PER PLANS. CONSTRUCT NON BEARING DRYWALL PARTITIONS, PROVIDE FRAMES DOORSAND HARDWARE. PROVIDE NEW ACCOUSTICAL CEIINGS. **SEPREATE PERMITS WILL BE REQUIRED M.E.P.S.**

  316. PermitPlumbing

    Permit 914236 · COMPLETED

    PLUMBING FOR FIT OUT OF OFFICE SPACE ALL CONNECTIONS WILL BE INTO EXISTING FIXTURES 3WC 3LAV 1EWC 1CS 1MS 1HS 11FS 2RD 1DW

  317. PermitMechanical

    Permit 908548 · COMPLETED

    FURNISH AND INSTALL THIRTEEN VAV CONTROL DAMPERS DUCT AND AIR DEVICES FOR NEW OFICE LAYOUT RELOCATE EXISTING SUPPLEMENT UNIT

  318. PermitElectrical

    Permit 911715 · COMPLETED

    INSTALL 67-SPEAKER/STROBES,4-STROBES,10-SMOKE DETECTORS,2-NAC PANELS AND 6-RELAYS ON AN EXISTING FIRE ALARM SYSTEM AS PER NFPA72

  319. PermitElectrical

    Permit 911344 · COMPLETED

    FURNISH AND INSTALL RECEPTACLES, FURNITURE FEEDS, FLOOR BOXES, LIGHTING FIXTURES & LIGHTING CONTROLS AS PER 2008 NEC (CC DISTRICT)

  320. PermitMajor alteration

    Permit 917728 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR THE USE OF A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS NEED TO BE OBTAINED FOR ALL OTHER WORK.

  321. PermitSuppression

    Permit 917857 · COMPLETED

    COMMERICAL- MODIFY EXISTING SYSTEM TO ACCOMDATE NEW IMPROVEMENTS FOR AREAS. RELOCATING 200 HEADS.

  322. PermitMajor alteration

    Permit 896909 · COMPLETED

    FOR LEVEL II ALTERATIONS TO THE SECOND FLOOR OF AN EXISTING BUILDING FOR USE AS AN OFFICE SPACE WITH ACCESSORY MEETING ROOMS. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. LAWFUL OCCUPANCY OF 600 PEOPLE WITH EXISTING NUMBER OF EXIT STAIRWAYS APPROVED PER VARIANCE GRANTED UNDER BBS CASE#34411. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  323. PermitDemolition

    Permit 897263 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  324. AppealBuilding standards appeal

    Appeal 34411 · CLOSED · APPROVED

    Related permit 875061 · ON 7/24/18 THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION # 875061.

  325. License terminal eventJOHN ROCCO JR: Food Estab, Retail Non-Permanent Location (Annual) L&I license filing marked inactive

    License 321570 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  326. PermitElectrical

    Permit 889323 · COMPLETED

    INSTALL 25- CAT 6A PLENUM RATED 4- PAIR CABLES. INSTALL 3- RG6 QUAD SHIELD PLENUM RATED COAX CABLES. LONGEST RUN: 200'. ALL WORK PER 2008 NEC (OFFICE)

  327. PermitElectrical

    Permit 879421 · COMPLETED

    INSTALL 4 NEW SPEAKER STROBES AND 3 STROBE ONLY AND 1 EXTENDER PANEL AND 1 DUAL RELAY PER NFPA 72 (OFFICE SPACE)

  328. PermitElectrical

    Permit 876042 · COMPLETED

    INSTALL 1 NEW 100AMP PANEL, RELOCATE 1-30 KVA TRANSFORMER, REWIRE 1-100AMP PANEL, RECEPTACLE, SWITCHES, NEW LIGHTING AS PER 2008 NEC (CC DISTRICT)

  329. PermitPlumbing

    Permit 883500 · COMPLETED

    INSTALL 2- WATER CLOSETS, 2- LAVATORIES, KITCHEN SINK, 20- GALLON WATER HEATER

  330. PermitMechanical

    Permit 879028 · COMPLETED

    HVAC INCLUDING RELATED DUCTWORK AND MECHANICAL EQUIPMENT AS PER PLANS.

  331. PermitSuppression

    Permit 877026 · COMPLETED

    RELOCATE 17 EXISTING SPRINKLER HEADS (COMMERCIAL)

  332. PermitMajor alteration

    Permit 871044 · COMPLETED

    LEVEL II ALTERATIONS INCLUDES NEW INTERIOR DRYWALL PARTITIONS. PROVIDE FRAMES DOORS AND HARDWARE. PROVIDE NEW FINISHES WITHIN OFFICE SPACE.** SEPARATE PERMIT IS REQUIRED FOR NEW ELECTRICAL, MECHANICAL & SPRINKLER WORK **

  333. PermitElectrical

    Permit 833779 · COMPLETED

    INSTALL NEW LIGHTING AND RECEPTACLES IN BUILDING CORE SPACE AN DELEVATOR LOBBY AS PER 2008 NEC (CC DISTRICT) REINSTALL NEW FIRE ALARM DEVICES WHERE EXISTING DEVICES ARE CURRENTLY INSTALLED AS PER NFPA72

  334. PermitElectrical

    Permit 840214 · COMPLETED

    WIRING FOR 92 STATION WITH CAT6A WIRES LONGEST RUN IS APPROX 150 FEET(OFFICE SPACE)

  335. PermitElectrical

    Permit 833783 · COMPLETED

    INSTALLATION OF BRANCH POWER AND LIGHTING FOR NEW TENANT AS PER 2008 NEC (CC DISTRICT) INSTALLATION OF ADDITIONAL FIRE ALARM DEVICES TO THE EXISITNG SYSTEM. RE-USE EXISTING PANELS FOR NEW BRANCH POWER AS PER NFPA72

  336. PermitPlumbing

    Permit 839396 · COMPLETED

    28TH FLOOR CORE BATHROOM RENOVATION WITH 13 PLUMBING FIXTURES AND PIPING

  337. PermitPlumbing

    Permit 836691 · COMPLETED

    INSTALL KITCHEN SINK, OPEN SITE DRAIN, WATER HEATER, EXTEND FROM EXISTING SANITARY AND DOMESTIC WATER

  338. PermitElectrical

    Permit 824171 · COMPLETED

    FURNISH & INSTALL (1) NEW STROBE ON EXISTING FIRE ALARM SYSTEM AS PER NFPA 72

  339. PermitMechanical

    Permit 832975 · COMPLETED

    HVAC INSTALLATION INCLUDING DUCTWORK AND MECHANCIAL EQUIPMENT (40)REGISTERS/DIFFUSERS

  340. PermitMechanical

    Permit 832987 · COMPLETED

    RELOCATE 6 DIFFUSERS, TO COMPLY WITH EZ PERMIT STANDARDS FOR DUCTWORK

  341. PermitMajor alteration

    Permit 829196 · COMPLETED

    LEVEL II INTERIOR NON-LOAD BEARING 28TH FLOOR CORE RENOVATIONS IN AN EXISTING HIGH-RISE OFFICE BUILDING AS PER SUBMITTED PLANS WORK TO INCLUDE NON-BEARING PARTITIONS, MILWORK AND FINISHES, NO CHANGE IN USE-OCCUPANCY CLASSIFICATION, SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS,

  342. PermitMajor alteration

    Permit 827763 · COMPLETED

    INTERIOR, TENANT FIT-OUT

  343. PermitSuppression

    Permit 831189 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  344. PermitSuppression

    Permit 831188 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  345. PermitElectrical

    Permit 828803 · COMPLETED

    INSTALLATION OF 18- PLENUM RATED CAT 6 LOW VOLTAGE COMPUTER WIRES.... IN ACCORDANCE WITH 2008 NEC (OFFICE)

  346. PermitSuppression

    Permit 827983 · COMPLETED

    RELOCATE 8 EXISTING SPRINKLER HEADS (COMMERCIAL)

  347. PermitMechanical

    Permit 825907 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  348. PermitElectrical

    Permit 816245 · COMPLETED

    FURNISH& INSTALL (4) SPEAKER/STROBES, (1) POWER SUPPLY, (1) SECURITY RELAY IN EXISTING SYSTEM AS PER NFPA 72 (CC DISTRICT)

  349. PermitMajor alteration

    Permit 820208 · COMPLETED

    INTERIOR ALTERATIONS FOR EXPANSION TO EXISTING TENANT SPACE.

  350. PermitElectrical

    Permit 821394 · COMPLETED

    RECONFIGURE EXISTING LIGHTING. FURNISH & INSTALL NEW POWER, RECEPTACLES AND POKE-THRUS IN EXISTING OFFICE SPACE AS PER 2008 NEC (CC DISTRICT)

  351. PermitElectrical

    Permit 811204 · COMPLETED

    FURNISH AND INSTALL 30 RECEPTS, 3 FURNITURE FEEDS, SWITCHES, 2-2X4 FIXTURES, 10 LED'S, OCCUPANCY SENSORS, 2 MAG LOCKS, CARD READER AS PER 2008 NEC (CC DISTRICT)

  352. PermitPlumbing

    Permit 815880 · COMPLETED

    INSTALLATION OF A KITCHEN SINK, OPEN SITE DRAIN AND 6- GALLON WATER HEATER. EXTEND FROM EXISTING SANITARY, VENT AND DOMESTIC WATER

  353. PermitSuppression

    Permit 814446 · COMPLETED

    THIS IS AN OVER THE COUNTER PERMIT APPLICATION. WE WILL BE RELOCATING (12) SPRINKLERS WITHIN THE FIDATO, IN THE 2 COMMERCE SQUARE BUILDING, ON THE 32ND FLOOR.FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  354. PermitElectrical

    Permit 812154 · COMPLETED

    FURNISH & INSTALL 46 CAT6 PLENUM RATED CABLES FOR VOICE & DATA LONGEST RUN 150' AS PER NEC 2008 (CC DISTRICT)

  355. PermitMechanical

    Permit 807609 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM FOR OFFICE SUITE 2300 TO INCLUDE RELOCATION OF FIVE (5) GRD'S AS PER APPROVED PLANS.

  356. PermitPlumbing

    Permit 807649 · COMPLETED

    ALTERATION: INTERIOR PLUMBING;STE 2300; 1 UTILITY TUB 1 WATER HEATER 1 DRINKING FOUNTAIN AND ASSOCIATED PIPING CW RELOCATE LAVS - THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  357. PermitMechanical

    Permit 810625 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  358. PermitElectrical

    Permit 807705 · COMPLETED

    MINOR ELECTRICAL ALTERATIONS IN AN EXISTING BUILDING AS PER 2008 NEC.

  359. PermitMajor alteration

    Permit 803803 · COMPLETED

    LEVEL II ALTERATIONS TO ACCOMMODATE NEW OFFICE LAYOUT ON THE 32ND FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING AS PER PLANS, WORK TO INCLUDE NON-BEARING PARTITIONS, MILWORK AND FINISHES, NO CHANGE IN USE-OCCUPANCY CLASSIFICATION, SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS,

  360. PermitMajor alteration

    Permit 743390 · COMPLETED

    FOR SELECTIVE INTERIOR DEMOLITION AND FOR LEVEL II ALTERATIONS TO CREATE NEW ACCESSIBLE TOILET FACILITIES IN AN EXISTING SPACE. WORK TO INCLUDE INTERIOR NON-BEARING PARTITIONS, PLUMBING FIXTURES, MILLWORK, AND FINISHES. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS. ** ALL ASBESTOS TO BE TREATED & REMOVED PRIOR TO COMMENCEMENT OF WORK. **

  361. PermitElectrical

    Permit 800795 · COMPLETED

    INSTALL 3 UNDER COUNTER LIGHTS RELOCATE 1 DUPLEX RECEPTACLE 2 QUAD RECEPTS RECONNECT 1 FURNITURE WHIP AS PER 2008 NEC (CC DISTRICT)

  362. PermitElectrical

    Permit 767101 · COMPLETED

    INSTALL NEW SPEAKER/STROBES AND STROBE AS PER NFPA72 (CC DISTRICT)

  363. PermitElectrical

    Permit 772393 · COMPLETED

    REMOVE POWER FROM OLD BUS SHELTER AND RE INSTALL POWER TO NEW BUS SHELTER FROM A 20AMP FUSE IN LIGHT POLE CLOSES TO SHELTER AS PER 2008 NEC (CC DISTRICT)

  364. PermitElectrical

    Permit 757044 · COMPLETED

    INSTALL 8 SPEAKER STROBES PER PLANS AND SPEC PER 2008 NEC.

  365. PermitElectrical

    Permit 755745 · COMPLETED

    INSTALL 15 DUPLEX RECEPTS, 2 QUAD RECEPTS AND RELOCATE 10 - 1X5 FIXTURES AS PER 2008 NEC (CC DISTRICT)

  366. PermitElectrical

    Permit 757113 · COMPLETED

    INSTALL (34) 24- GAUGE VOICE/DATA STATIONS, TERMINATIONS AND TESTING.... IN ACCORDANCE WITH 2008 NEC (OFFICE BUILDING)

  367. PermitMajor alteration

    Permit 752818 · COMPLETED

    LEVEL II ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.

  368. PermitPlumbing

    Permit 754458 · COMPLETED

    FURNISH AND INSTALL 1 KITCHEN SINK AND 1 (6)WATER HEATER, EXTEND FROM EXISTING SANITARY VENT AND DOMESTIC WATER.- THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004

  369. PermitSuppression

    Permit 754565 · COMPLETED

    RELOCATE (24) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES.

  370. PermitMechanical

    Permit 754186 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  371. PermitMajor alteration

    Permit 748923 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING OFFICE SPACE ON THE 5TH FLOOR LEVEL OF AN EXISTING BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.

  372. PermitElectrical

    Permit 710670 · COMPLETED

    FURNISH AND INSTALL 250 LF OF EMPTY 2"EMT CONDUIT WITH JUNCTION BOXES INSTALLED AS PER 2008 NEC (CC DISTRICT)

  373. PermitMechanical

    Permit 666461 · COMPLETED

    HVAC INSTALLATION INCLUDING, VAV BOX, DUCT AND AIR DEVICES AS PER PLAN.

  374. PermitElectrical

    Permit 659905 · COMPLETED

    MAKE SAFE ELECTRICAL WIRING FOR DEMOLITION OF EXISTING TENANT SPCE. INSTALLATION OF TEMP LIGHTING PER 2008 NEC (OFFICE SPACE)CC DISTRICT

  375. PermitElectrical

    Permit 643779 · COMPLETED

    FURNISH AND INSTALL 198 WORK AREA OUTLETS CLASSROOMS CONSISTING OF 310 CAT6, 10 CAT5E AND 3RG6 TELECOMMUNICATION CABLE FURNISH AND INSTALL TELECOM ROOM FITOUTS AS PER 2008 NEC (CC DISTRICT)

  376. PermitElectrical

    Permit 647451 · COMPLETED

    10 MICROPHONE,16 CEILING SPEAKERS,2 CAMERAS,2 A/C RACKS,5 LCD DISPLAYS,1 VIDEO DISPLAY AND 4 WALL PLATES PER 2008 NEC (OFFICE SPACE)

  377. PermitElectrical

    Permit 639914 · COMPLETED

    ELECTRICAL WORK FOR TENANT FITOUT INCLUDING LIGHTS,RECEPTACLES AND SWITCHES PER 2008 NEC (OFFICE SPACE)INSTALL FIRE ALARM PER NFPA 72

  378. PermitElectrical

    Permit 638989 · COMPLETED

    FURNISH AND INSTALL 246 WORK AREA OUTLETS CLASSROOMS CONSISTING OF 483 CAT6 TELECOMMUNICATIONS CABLES. FURNISH AND INSTALL TELECOMMUNICATION CLOSET BUILDOUT PER 2008 NEC (OFFICE SPACE)CC DISTRICT)

  379. PermitSuppression

    Permit 644021 · COMPLETED

    RELOCATE 201 EXISTING SPRINKLER HEADS (COMMERCIAL)

  380. PermitPlumbing

    Permit 640194 · COMPLETED

    INSTALLATION OF TWO PANTRY SINKS, HANDI-CAP WATER CLOSET AND LAVATORY

  381. PermitElectrical

    Permit 634954 · COMPLETED

    INSTALL LIGHTS,SWITCHES,OUTLETS AND RECEPTACLES PER 2008 NEC (OFFICE SPACE)INSTALL NEW FIRE ALARM PER NFPA 72

  382. PermitMechanical

    Permit 638701 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM INCLUDING DUCTWORK TO ACCOMODATE NEW OFFICE LAYOUT ON 25TH FLOOR OF AN EXISTING HIGH RISE BUILDING AS PER PLANS

  383. PermitSuppression

    Permit 640869 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  384. PermitSuppression

    Permit 638071 · COMPLETED

    RELOCATE 168 EXISITING SPRINKLER HEADS (COMMERCIAL)

  385. PermitPlumbing

    Permit 635340 · COMPLETED

    INSTALL WATER CLOSET, LAVATORY, 3- KITCHEN SINKS, 2- OPEN SITE DRAINS

  386. PermitElectrical

    Permit 636900 · COMPLETED

    ADD 2 SWITCHES AND 6 OUTLETS TO EXISTING CIRCUITS. REMOVE AND RELOCATE 2 STROBES. NO NEW CIRCUITRY AS PER 2008 NEC (CC DISTRICT)

  387. PermitMechanical

    Permit 632682 · COMPLETED

    HVAC INSTALLATION INCLUDING DUCTWORK AND MECHANICAL EQUIPMENT AS PER PLANS 127-REGISTERS/DIFFUSERS

  388. PermitElectrical

    Permit 627813 · COMPLETED

    REMOVE AND RELOCATE 1 EXISTING STROBE,REMOVE AND RELOCATE 1 EXISTING SPEAKER/STROBE AND ADD 6 NEW SPEAKER/STROBES PER NFPA 72 (OFFICE SPACE)

  389. PermitMajor alteration

    Permit 630383 · COMPLETED

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. NO CHANGE IN OCCUPANT LOAD. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK.

  390. InvestigationBP_BLDG

    Case 476060 · PASSED

    The cited inspection visit was marked passed.

  391. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 474420 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  392. PermitMajor alteration

    Permit 625036 · COMPLETED

    FOR INTERIOR ALTERATIONS TO AN EXISTING STRUCTURE TO INCLUDE THE INSTALLATION OF NEW INTERIOR PARTITION WALL CONFIGURATION AND WALL/FLOOR/CEILING FINISHING. (IEBC 2009, COMPLIANCE PATH: WORK-AREA METHOD, LVL II ALTERATIONS)

  393. PermitAlteration

    Permit 632148 · COMPLETED

    EZ STANDARD LIMITED COMMERCIAL ALTERATIONS & REPAIRS- FOR THE LIMITED DEMOLITION AND COMMERCIAL ALTERATIONS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  394. PermitElectrical

    Permit 625120 · COMPLETED

    FURNISH & INSTALL 67 WORK AREA OUTLETS CONSISTING OF 128 CAT6 TELECOMMUNICATION CABLE, PLENUM RATED LONGEST RUN 200 FT AS PER NEC 2008 (CC DISTRICT)

  395. PermitElectrical

    Permit 624749 · COMPLETED

    FURNISH & INSTALL 36 WORK AREA OUTLETS CONSISTING OF CAT6 TELECOMMUNICATION CABLE & CLOSET BUILD OUT AS PER NEC 2008 (COMM)

  396. PermitElectrical

    Permit 624635 · COMPLETED

    FURNISH AND INSTALL 1 NAC,16 SPEAKER/STROBE,6 STROBES PER NFPA 72(OFFICE SPACE)

  397. PermitMajor alteration

    Permit 626552 · COMPLETED

    LEVEL II ALTERATION AS PER PLAN.

  398. PermitMechanical

    Permit 620940 · COMPLETED

    HVAC INCLUDING DUCTWORK AS PER PLAN, 31-REGISTERS/DIFFUSERS

  399. PermitDemolition

    Permit 628696 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  400. PermitSuppression

    Permit 626986 · COMPLETED

    RELOCATE 22 EXISTING SPRINKLER HEADS (COMMERCIAL)

  401. PermitMechanical

    Permit 623035 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMMODATE NEW OFFICE LAYOUT ON 11TH FLOOR TO INCLUDE NEW DUCTWORK AND VAV BOXES AS PER APPROVED PLANS.

  402. PermitPlumbing

    Permit 623195 · COMPLETED

    INSTALL WATER CLOSET, LAVATORY, KITCHEN SINK, OPEN SITE DRAIN/INDIRECT WASTE (FOR HVAC); CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC WATER

  403. PermitElectrical

    Permit 625556 · COMPLETED

    INSTALLATION OF 80 DUAL DATA LINES-OFFICE BLDG ONLY

  404. PermitNew Construction

    Permit 617229 · Completed

    PROVIDE & INSTALL AUDIO VISUAL CABLING AND COMPONENTS ON FLOORS 18 TO 24 ALL CABLING WILL BE INSTALL IN J HOOKS AND PENETRATIONS WILL BE FIRE STOPPED AS PER 2008 NEC (CC DISTRICT)

  405. PermitElectrical

    Permit 622079 · COMPLETED

    11TH FLOOR ELECTRICAL ALTERATIONS - RELOCATE (10)EXISTING 1'-0"X5'-0"LUMINAIRES, (6)FURNITURE FEEDS, (12)RECEPTACLES & (5)SWITCHES - REUSE THE EXISTING CIRCUITS - THE INSTALLATION WILL COMPLY WITH THE 2008 NEC

  406. PermitAddition and/or Alteration

    Permit 619813 · Completed

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. NO CHANGE IN OCCUPANT LOAD. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK.

  407. PermitElectrical

    Permit 616828 · COMPLETED

    ADD 8 SPEAKER/STROBES ONTO AN EXISTING APPROVED FIRE ALARM SYSTEM AS PER NFPA 72 (CC DISTRICT)

  408. PermitMajor alteration

    Permit 619716 · COMPLETED

    INTERIOR FIT OUT OF NON LOAD BEARING WALLS.

  409. PermitElectrical

    Permit 606668 · COMPLETED

    FURNISH AND INSTALL 104 WORK AREA OUTLETS CONSISTING OF (215) CAT6 AND 6 RG6 CABLES PER 2008 NEC (OFFICE SPACE)

  410. PermitSuppression

    Permit 622546 · COMPLETED

    RELOCATE (16) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER ALL NFPA NO. 13 AND LOCAL CODES.

  411. PermitElectrical

    Permit 620697 · COMPLETED

    PARTIAL 32ND FLOOR ELECTRICAL ALTERATIONS - FURNISH AND INSTALL (30)RECEPTACLES, (5)GFI'S, (5)POKE-THRUS, POWER TO FURNITURE FEEDS, RE-WORK THE LUMINAIRE LAYOUT AND WIRING FOR A HOT WATER HEATER - THE INSTALLATION WILL BE IN COMPLIANCE WITH THE 2008 NEC

  412. InvestigationBP_BLDG

    Case 474420 · CLOSED

    City marked the record closed; open the case for the closing reason.

  413. PermitDemolition

    Permit 619806 · COMPLETED

    PARTIAL DEMO OF 11TH, 12TH, & 15TH FLOORS.EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  414. PermitMajor alteration

    Permit 596626 · COMPLETED

    REMOVAL OF EXISTING PAVERS AND ROOF SYSTEM, WHICH IS TO BE REPLACED PER BUILDING/LANDLORD STANDARDS. PROPOSED OCCUPIABLE ROOF TERRACE TO INCLUDE NEW PEDESTAL PAVER SYSTEM, GUARDRAIL AND LANSCAPE, FURNISHINGS AND UTILITIES FOR USE BY OFFICE OCCUPANTS ONLY

  415. PermitSuppression

    Permit 617230 · COMPLETED

    RELOCATE (19) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER ALL NFPA NO. 13 AND LOCAL CODES.

  416. PermitPlumbing

    Permit 615564 · COMPLETED

    INSTALL SINK, CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC WATER

  417. PermitMajor alteration

    Permit 613223 · COMPLETED

    INTERIOR ALTERATIONS AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK.

  418. PermitMechanical

    Permit 615279 · COMPLETED

    FOR HVAC ACTIVITY ON THE 30TH FLOOR, RELOCATE 18 DIFFUSERS AND INSTALL TWO (2) VAV BOXES WITHIN AN EXISTING HVAC SYSTEM

  419. PermitElectrical

    Permit 614586 · COMPLETED

    REWORK LIGHTING LAYOUT,ADD 20 DUPLEX RECPTACLES,5 POKE THRU'S,POWER TO 1 HOT WATER HEATER PER 2008 NEC (OFFICE SPACE)

  420. InvestigationBP_BLDG

    Case 476060 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  421. ViolationPERMB- FINAL PRE-CO INSP

    Case 593109 · Violation 3572594 · Code A-402.5/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  422. InvestigationBP_BLDG

    Case 474420 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  423. PermitElectrical

    Permit 602913 · COMPLETED

    FURNISH & INSTALL 18-SPEAKER STROBES, 8-STROBES, 1-HEAT DETECTOR & 1-CONTROL MODULE ON EXSISTING PANEL AS PER NFPA 72 CC DISTRICT

  424. PermitElectrical

    Permit 598717 · COMPLETED

    F/I ALL NECESSARY LIGHTING & POWER PER PLANS.

  425. ViolationPERMB- TO COMPLY VIOL

    Case 476060 · Violation 3583124 · Code A-301.6/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  426. ViolationPENALTY- NO BLDG PERM INFO

    Case 476060 · Violation 3583126 · Code A-901.13/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  427. ViolationPERMB- ALTER REPAIR INT PART (Building permit required for interior alteration or repair)

    Case 476060 · Violation 3583123 · Code A-301.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  428. ViolationPERMB- FINAL PRE-CO INSP

    Case 476060 · Violation 3583125 · Code A-402.5/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  429. InvestigationBP_BLDG

    Case 476060 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  430. PermitElectrical

    Permit 595956 · COMPLETED

    ONLY GEAR THAT APPLIES IS NEW 30KVA TRANSFORMER TL-1 AND PANEL TL18 PER 2008 NEC (OFFICE SPACE)

  431. ViolationPERMB- ALTER REP'R EXT PORTION

    Case 474420 · Violation 3609679 · Code A-301.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  432. ViolationPERMB- EXTEND FIRE SUPP SYS

    Case 474420 · Violation 3609678 · Code A-301.1/28 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  433. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 474420 · Violation 3609680 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  434. InvestigationBP_BLDG

    Case 474420 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  435. PermitElectrical

    Permit 598969 · COMPLETED

    INSTALL THIRTY SIX CATEGORY 6 PLENUM RATED DATA CABLE LOCATIONSAS PER 2008 NEC (CC DISTRICT)

  436. PermitPlumbing

    Permit 598770 · COMPLETED

    FURNISH AND INSTALL 1 KITCHEN SINK 1 W.C. 1 LAV. AND 1 FLOOR DRAIN - CONNECT TO EXISTING SANITARY, VENT AND DOMESTIC WATER (ALL WORK TO COMPLY WITH 2004 PHILADELPHIA PLUMBING CODE)

  437. PermitSuppression

    Permit 597966 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  438. InvestigationCI INSP

    Case 463302 · PASSED

    The cited inspection visit was marked passed.

  439. PermitMajor alteration

    Permit 593109 · COMPLETED

    LEVEL II ALTERATIONS AS PER PLAN.

  440. PermitMechanical

    Permit 595204 · COMPLETED

    HVAC INSTALLATION AS PER PLAN.

  441. PermitAlteration

    Permit 594736 · COMPLETED

    REMOVE EXISTING PAVERS, WATERPROOFING MEMBRANE AND LIGHTWEIGHT INSULATED CONCRETE DOWN TO STRUCTURAL CONCRETE DECK. FURNISH AND INSTALL NEW WATERPROOFING MEMBRANE, DRAINAGE COMPOSITE BOARD AND OVERBURDEN OVER EXISTING STRUCTURAL CONCRETE DECK.

  442. PermitZoning/use

    Permit 572788 · COMPLETED

    FOR THE ERECTION OF A ROOF DECK ABOVE A PORTION OF THE 18TH FLOOR OF AN EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. ROOF DECK ACCESSORY TO PREVIOUSLY APPROVE BUSINESS AND PROFESSIONAL OFFICES ON THE 18TH FLOOR. NO CHANGE TO PREVIOUSLY APPROVED USES. NO SIGNS ON THIS APPLICATION.

  443. License terminal eventPHILADELPIHA PLAZA PHASE II AKA COMMERCE SQ (EXPERT PARKING): Public Garage / Parking Lot business license marked inactive

    License 469560 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  444. PermitDemolition

    Permit 592233 · COMPLETED

    8000 SQUARE FEET, INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILINGS ONLY. NO OTHER WORK ALLOWED UNDER THIS PERMIT. NO STRUCTURAL CHANGES. MUST MAINTAIN ALL CODE REQUIRED FIRE RATING ON WALL AND FLOOR/CEILING ASSEMBLIES. THREE SETS OF PLANS DRAWN TO PROFESSIONAL QUALITY ARE TO BE SUBMITTED FOR REVIEW AND APPROVAL BY THE DEPARTMENT BEFORE WORK ON RENOVATION STARTS. CONTACT STREETS DEPARTMENT FOR DUMPSTER PERMIT AND FOOTWAY CLOSURE PERMITS.

  445. AppealZoning board appeal

    Appeal 24295 · CLOSED · Granted

    Related permit 572788 · SPECIAL EXCEPTION FOR THE ERECTION OF A ROOF DECK ABOVE A PORTION OF THE 18TH FLOOR OF AN EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. ROOF DECK ACCESSORY TO PREVIOUSLY APPROVE BUSINESS AND PROFESSIONAL OFFI

  446. PermitMajor alteration

    Permit 586374 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS TO INCLUDE DEMOLITION AND CONSTRUCTION OF NON-LOAD BEARING PARTITIONS, INTERIOR FINISHES AS PER APPROVED PLANS.

  447. PermitDemolition

    Permit 586919 · EXPIRED

    INTERIOR DEMO OF NON LOAD BEARING WALLS

  448. PermitElectrical

    Permit 587046 · COMPLETED

    INSTALL 6DUPLEX RECEPTS,2WALL SENSORS,1EXIT SIGN,REMOVE AND RELOCATE 4 EXISTING LIGHTS AS PER 2008 NEC (CC DISTRICT)

  449. PermitAdministrative

    Permit 529522 · COMPLETED

    PRELIMINARY PLAN REVIEW

  450. InvestigationCI INSP

    Case 463297 · PASSED

    The cited inspection visit was marked passed.

  451. InvestigationCI INSP

    Case 463302 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  452. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 463297 · Violation 3419679 · Code FC-13-1007 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  453. ViolationFIRE RESISTANCE RATING

    Case 463297 · Violation 3419684 · Code FC-13-703 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  454. ViolationVIOL C&I MESSAGE

    Case 463297 · Violation 3419678 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  455. ViolationOPEN JUNCTION BOXES

    Case 463297 · Violation 3419680 · Code FC-13-605.6 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  456. ViolationVIOL C&I MESSAGE

    Case 463302 · Violation 3448274 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  457. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 463302 · Violation 3448277 · Code FC-13-904 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  458. ViolationViolation

    Case 463302 · Violation 3448275 · Code FC-13-1006 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  459. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 463302 · Violation 3448276 · Code FC-13-901 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  460. InvestigationCI INSP

    Case 463297 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  461. InvestigationCI INSP

    Case 463302 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  462. PermitDemolition

    Permit 578994 · COMPLETED

    INTERIOR DEMOLITION, NO LOAD BEARING WALLS.

  463. PermitElectrical

    Permit 556050 · COMPLETED

    SECURITY CABLING FOR FLOORS AS PER NEC 2008. INSTALLATION TO COMPLY WITH ARTICLES 300.21, 300.22 & 725 OF THE 2008 NEC.

  464. PermitPlumbing

    Permit 541026 · COMPLETED

    F&I 15 SINKS,55 WATER CLOSETS,14 URINAL,57 LAV,3 SHOWERS,14 DRINKING FOUNTAINS,16 FLOOR DRAINS AND RELOCATE 6 MOP SINKS (OFFICE SPACE)

  465. PermitElectrical

    Permit 547167 · COMPLETED

    INSTALL FIRE ALARM PER 2008 NEC & NFPA 72 (OFFICE SPACE)

  466. PermitElectrical

    Permit 546176 · COMPLETED

    FURNISH AND INSTALL CAT6 LOW VOLTAGE COMMUNICATION CABLES FOR 72 WORK AREA OUTLETS PER 2008 NEC (OFFICE SPACE)

  467. PermitElectrical

    Permit 550140 · COMPLETED

    INSTALL 436 LOW VOLTAGE SOUND MASKING SPEAKERS ON 18TH TO 24TH FLOORS AS PER 2008 NEC (CC DISTRICT)

  468. PermitElectrical

    Permit 545173 · COMPLETED

    PROVIDE & INSTALL 2150 CAT6 PLENUM CABLES AS PER ARTICLES 300.21, 300.22 & 800 OF THE 2008 NEC. ALLCABLES TO BE SUPPORTED WITH J- HOOKS.

  469. PermitMechanical

    Permit 548962 · COMPLETED

    RELOCATE 11-DIFFUSERS.

  470. PermitElectrical

    Permit 541401 · COMPLETED

    CORRIDOR RENOVATION AND REMOVE AND REINSTALL EXISTING F/A DEVICES PER 2008 NEC & NFPA 72 (OFFICE SPACE)

  471. PermitElectrical

    Permit 541442 · COMPLETED

    FURNISH AND INSTALL LIGHTING AND POWER PER 2008 NEC (OFFICE SPACE)

  472. PermitElectrical

    Permit 539914 · COMPLETED

    INSTALL ADDITIONAL DEVICES TO EXISTING BLDG SYSTEM FROM NEW MDF LOCATION AS PER NFPA 72 (CC DISTRICT)

  473. PermitMechanical

    Permit 535946 · COMPLETED

    FOR LEVEL II ALTERATIONS TO EXISTING MECHANICAL SYSTEM ON THE 30TH FLOOR OF AN EXISTING BUILDING. ALTERATIONS TO INLCUDE THE REMOVAL/REPLACEMENTS OF REGISTERS, DIFFUSERS AND MECHANICAL EQUIPMENT WITH ASSOCIATED DUCT WORK. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ELECTRICAL, AND PLUMBING WORK.

  474. PermitMajor alteration

    Permit 541729 · COMPLETED

    LEVEL II ALTERATIONS INCLUDE NEW FINISHES ON 30TH FLOOR

  475. PermitDemolition

    Permit 544048 · COMPLETED

    INTERIOR DEMOLITION, NO LOAD BEARING WALLS.

  476. PermitElectrical

    Permit 536259 · COMPLETED

    ELECTRICAL WORK FOR TENANT FITOUT PROJECT AS PER 2008 NEC (CC DISTRICT) RELOCATE EXISTING FIRE ALARM HORN AND STROBES,INSTALL NEW HORN AND STROBES,NEW NAC EXTENDER PANEL,INSTALL SECURITY WIRING FOR 4 DOOR LOCKS & RTE AS PER 2008 NEC & NFPA72

  477. PermitSuppression

    Permit 542545 · COMPLETED

    RELOCATE EXISTING SPRINKLER HEADS (20) IN ORDER TO ACCOMMODATE TENANT AS PER ALL NFPA NO. 13 AND LOCAL CODES.

  478. PermitSuppression

    Permit 542549 · COMPLETED

    RELOCATE (876) SPRINKLER HHEADS IN ORDER TO ACCOMMODATE TENANT LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES.

  479. PermitPlumbing

    Permit 542557 · COMPLETED

    INSTGALLATION OF WATER CLOSET, LAVY SINK, FLOOR DRAIN, AND ELEC WATER COOLER IN TO EXISTING SANITARY STACK

  480. PermitMechanical

    Permit 541013 · COMPLETED

    HVAC, INCLUDING DUCTWORK AND MECHANICAL EQUIPMENT,PIPING, ACCESSORY MECHANICALS AS PER PLANS AND SCHEDULE.

  481. PermitPlumbing

    Permit 541678 · COMPLETED

    2 PANTRY SINKS

  482. PermitMajor alteration

    Permit 539499 · COMPLETED

    FULL INTERIOR RENOVATION/RESTACK OF FLOORS 18 THROUGH 24 OF TWO COMMERCE SQUARE.

  483. PermitPlumbing

    Permit 535283 · COMPLETED

    2 PANTRY SINKS

  484. PermitSuppression

    Permit 534163 · COMPLETED

    RELOCATE (51) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES.

  485. PermitElectrical

    Permit 527259 · COMPLETED

    RECONFIGURE EXISTING POWER & LIGHTING FOR NEW SPACE DESIGN AS PER NEC 2008 (OFFICE SPACE)

  486. PermitMajor alteration

    Permit 530535 · COMPLETED

    FOR DEMOLITION OF EXISTING PARTITION WALLS & FOR LEVEL II ALTERATIONS W. NO CHANGE OF OCCUPANCY CLASSIFICATION WITHIN AN EXIST. HIGH-RISE MIXED-USE OFFICE BUILDING TO INCLUDE ERECTION OF PARTITIONS FOR ADMIN, COPY ROOM AREAS AND OFFICES AS PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED.

  487. PermitElectrical

    Permit 524812 · COMPLETED

    PROVIDE AND INSTALL 210 CAT5E PLENUM CABLE @ AVERAGE OF 150' ALL CABLING WILL BE INSTALLED IN J HOOKS AND ALL PENETRATIONS WILL BE FIRE STOPPED PER 2008 NEC (OFFICE SPACE)

  488. PermitSuppression

    Permit 530016 · COMPLETED

    RELOCATE 15 SPRINKLERS ON THE 21ST AND 25TH FLOOR IN THE MDF ROOM AND SWING SPACE

  489. PermitMechanical

    Permit 526571 · COMPLETED

    FOR THE INSTALLATION OF ELEVEN (11) REGISTERS/DIFFUSERS AND ASSOCIATED DUCT WORK ON 21ST FLOOR, PWC-MDF ROOM PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR KITCHEN HOODS, ELECTRICAL, PLUMBING, FIRE SUPPRESSION.

  490. PermitMajor alteration

    Permit 521174 · COMPLETED

    INTERIOR ALTERATION TO EXISTING OFFICE SPACE. SEPARATE ELECTRICAL PERMIT REQUIRED.

  491. PermitMajor alteration

    Permit 521167 · COMPLETED

    INTERIOR ALTERATIONS - TENANT IMPROVEMENTS, NEW MDF ROOM & PUMP CLOSET WITH NEW PARTITIONS, CEILING. STRUCTURAL MODIFICATIONS EXISTING CONCRETE FLOOR SLAB AND FRAMING SUPPORT FOR EQUIPMENT, MECHANICAL, UPGRADES TO FINISHES & MECHANICAL. ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS

  492. PermitAdministrative

    Permit 504200 · COMPLETED

    AMENDMENT TO PERMIT NUMBER 487338 TO REFLECT PANTRY/ TOILET ROOM MODIFICATIONS.

  493. PermitElectrical

    Permit 493363 · COMPLETED

    FURNISH AND INSTALL 7 NEW SPEAKER STROBES, 1 NEW NAC PANEL AS PER 2008 NEC & NFPA 72(OFFICE BLDG)

  494. PermitElectrical

    Permit 493364 · COMPLETED

    FURNISH AND INSTALL 8 NEW SPEAKER STROBES AS PER 2008 NEC & NFPA 72 (OFFICE BLDG)

  495. InvestigationCI INSP

    Case 408917 · PASSED

    The cited inspection visit was marked passed.

  496. PermitAdministrative

    Permit 508993 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR 60 DAYS. ORIGINAL PERMIT #487338.

  497. PermitElectrical

    Permit 507960 · COMPLETED

    DISCONNECT AND RECONNECT 6 WORK STATION FEEDS AND RELOCATE 4 EXISTING LIGHTS PER 2008 NEC (OFFICE SPACE)

  498. PermitElectrical

    Permit 500531 · COMPLETED

    20 CARDREADER SYSTEMS WITH LOW VOLTAGE ELECTRIC LOCKS ON 7TH & 8TH FLOORS AS PER 2008 NEC (OFFICE BLDG)

  499. PermitElectrical

    Permit 499221 · COMPLETED

    9-SPEAKER STROBES, 2-STROBES & 1-NAC PANEL AS PER NEC 2008 & NFPA 72 (OFFICE BLDG)

  500. PermitElectrical

    Permit 497877 · COMPLETED

    FURNISH AND INSTALL ALL NECESSARY LIGHTING,POWER & TELE/DATA PER 2008 NEC

  501. InvestigationCI INSP

    Case 407145 · PASSED

    The cited inspection visit was marked passed.

  502. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 408917 · Violation 2985064 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  503. ViolationINT KITCHEN-REPLACE LINK/HEAD

    Case 408917 · Violation 2985063 · Code FC-904.11/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  504. ViolationVIOL C&I MESSAGE

    Case 408917 · Violation 2985062 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  505. InvestigationCI INSP

    Case 408917 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  506. PermitElectrical

    Permit 491956 · COMPLETED

    OFFICE FITOUT OF TWO EXISTING FLOOR INSTALL NEW LIGHT FIXTURES,LIGHTING CONTROLS,RECEPTACLES AND FIRE ALARM DEVICE PER 2008 NEC & NFPA 72 (OFFICE SPACE)

  507. ViolationVIOL C&I MESSAGE

    Case 407145 · Violation 2970563 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  508. ViolationHIRISE-PAY HIRISE FEE

    Case 407145 · Violation 2970564 · Code FC-408.12/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  509. InvestigationCI INSP

    Case 407145 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  510. PermitElectrical

    Permit 486183 · COMPLETED

    FURNISH AND INSTALL 450 CATEGORY 6 PLENUM CABLES, AVERAGE CABLE PULL 150 FEET (OFFICE BLDG)

  511. PermitElectrical

    Permit 499811 · COMPLETED

    FURNISH AND INSTALL 98 CATEGORY 6 PLENUM CABLES, AVERAGE CABLE PULL 145 FEET 'ONLY' AS PER 2008 NEC (OFFICE)

  512. PermitElectrical

    Permit 493381 · COMPLETED

    PROVIDE & INSTALL APPRX 505 CAT6 DATA CABLES THROUGHOUT FLS 7 & 8, COPPER & FIBER OPTIC BACKBONE CABLE BETWEEN FLS, PROVIDE LABOR TO INSTALL AV CABLING & EQUIP THROUGHOUT FLS 7 & 8.INSTALLATION TO COMPLY WITH ARTICLES 300.21,770 & 800 OF THE 2008 NEC.

  513. PermitNew Construction

    Permit 493333 · Completed

    INSTALL CABLING DATA ONE THE 11TH FLOOR OFFICE W/TIE IN TO THE 14TH FLOOR AS PER NEC 2008 (OFFICE BLDG)

  514. PermitPlumbing

    Permit 497212 · COMPLETED

    INSTALLATION OF A KITCHEN SINK

  515. PermitMechanical

    Permit 497818 · COMPLETED

    MECHANICAL DEMO AND INSTALLATION OF NEW - RECONFIGURATION OF EXISTING HVAC SYSTEM FOR FLOOR LAYOUT, DEMO EXISTING DUCTWORK AND DIFFUSERS, UPGRADES TO HVAC SYSTEM, RELOCATE EXISTING VAC FAN POWERED BOXES AND INSTALLATION OF NEW VAV BOXES, DIFFUSERS, DUCTWORK, CONNECT TO EXISTING SYSTEM AS PER PLANS AND MECHANICAL SPECIFICATIONS.

  516. PermitPlumbing

    Permit 492454 · COMPLETED

    PLUMBING FITOUT FOR NEW OFFICE RENOVATION (OFFICE BLDG)

  517. PermitMajor alteration

    Permit 495521 · COMPLETED

    PARTIAL RENOVATION OF 12TH, 14TH, AND 16TH FLOORS.

  518. PermitMechanical

    Permit 492020 · COMPLETED

    ALTERATIONS TO AN EXISTING HVAC SYSTEM TO RELOCATE AND INSTALL NEW VAV BOXES, HEAT PUMPS & AIR DEVICES. ALTERATIONS ALSO TO INCLUDE NEW REGISTERS/DIFFUSERS AND ALL SUPPLEMENTAL FANS, EXHAUSTS AND DUCTWORK AS SHOWN IN APPROVED PLANS.

  519. PermitMajor alteration

    Permit 492996 · COMPLETED

    LEVEL 2 INTERIOR ALTERATIONS FOR A TENANT FITOUT ON THE FIFTH FLOOR AS PER APPROVED PLANS.

  520. PermitSuppression

    Permit 496601 · COMPLETED

    RELOCATE (20) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT FITOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES.

  521. PermitMajor alteration

    Permit 487338 · COMPLETED

    RENOVATIONS TO EXISTING OFFICE SPACE ON THE 7TH AND 8TH FLOORS. NO CHANGE IN OCCUPANCY CLASSIFICATION.

  522. PermitSuppression

    Permit 493493 · COMPLETED

    RELOCATING (37) SPRINKLERS IN THE RELIANCE STANDARD LIFE INSURANCE SPACE ON THE 11TH-16TH FLOOR

  523. PermitNew Construction

    Permit 486624 · Expired

    FURNISH & INSTALL 54-CATEGORY 6 PLENUM CABLE LONGEST RUN 150' AS PER NEC 2008

  524. PermitElectrical

    Permit 493666 · COMPLETED

    REMOVE & RELOCATE 30-1X5 FIXTURES, 20-DUPLEX RECPTS, 10-FURNITURES FEED, & 4-WALL SENSORS AS PER NEC 2008 (OFFICE)

  525. PermitElectrical

    Permit 486111 · COMPLETED

    FURNISH & INSTALL 2-SINGLE POLE SW, RELOCATE 12-EXISTING 1X5 FIXTURES, FURNISH & INSTALL 11-DUPLEX OUTLETS, FURNISH & INSTALL 4-WALL MOUNTED FURNITURE FEED AS PER NEC 2008 (OFFICE BLDG)

  526. PermitElectrical

    Permit 485654 · COMPLETED

    EXTEND EXISTING 480V FEEDER, INSTALL 100A 277/480 PANEL, 30KVA XFORMER, 100A 120/208V PANEL, 13 1X5 FIXTURES, 19 RECEPTACLES & 2 FLOOR RECEPTACLES.

  527. PermitSuppression

    Permit 492028 · COMPLETED

    RELOCATE 466 SPRINKLERS

  528. PermitSuppression

    Permit 491597 · COMPLETED

    RELOCATE (11) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT WALL AND CEILING LAYOUT AS PER ALL NFPA NO 13 AND LOCAL CODES. (39TH FLOOR)

  529. PermitSuppression

    Permit 491598 · COMPLETED

    RELOCATE (8) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT WALL AND CEILING LAYOUT AS PER ALL NFPA NO 13 AND LOCAL CODES. (39TH FLOOR)

  530. PermitMechanical

    Permit 488229 · COMPLETED

    HVAC INSTALLATION INCLUDING DUCTWORK, AS PER PLANS. 13 REGISTERS/DIFFUSERS

  531. PermitPlumbing

    Permit 487102 · COMPLETED

    INSTALLATION OF KITCHEN SINK

  532. PermitPlumbing

    Permit 487101 · COMPLETED

    INSTALLATION OF KITCHEN SINK

  533. PermitMechanical

    Permit 488244 · COMPLETED

    RELOCATE 18 DIFFUSERS

  534. PermitMechanical

    Permit 483730 · COMPLETED

    NEW DUCTWORK, NEW VAV BOXES (14) AND RELOCATION OF EXISTING VAV BOXES. ALSO INCLUDING 3 INLINE EXHAUST FANS AND CONTROLS (PNEUMATIC) FOR VAV BOXES WITHIN THE 35 THRU 37 FLOOR OFFICES AS PER PLAN.

  535. PermitMajor alteration

    Permit 483220 · COMPLETED

    FOR DEMOLITION OF EXIT. PARTITION WALLS & FOR LEVEL II ALTERATIONS W. NO CHANGE OF OCCUPANCY CLASSIFICATION WITHIN AN EXIST. HIGH-RISE MIXED-USE OFFICE BUILDING TO INCLUDE ERECTION OF PARTITIONS FOR ADMIN & COPY ROOM AREAS; BUILDING IS FULLY SPRINKLERED.

  536. PermitDemolition

    Permit 471090 · COMPLETED

    INTERIOR DEMO OF NON LOAD BARING DRYWALL PARTITIONS AND FINISHES.(7TH. PARTIAL AND 36TH FLOOR)

  537. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 319230 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  538. PermitMajor alteration

    Permit 483213 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS TO CREATE A NEW TENANT SPACE IN SUITE '3915' OF AN EXISTING HIGH-RISE OFFICE BUILDING. ALTERATIONS TO INCLUDE NEW OFFICE, CONFERENCE AND WORK AREAS AS WELL AS ACCESSIBLE EMPLOYEE PANTRY AND COPY/WORK ROOM. SEPARATE PERMITS REQUIRED FOR HVAC, ELECTRICAL AND FIRE SUPPRESSION SYSTEMS.

  539. PermitPlumbing

    Permit 484115 · COMPLETED

    FURNISH AND INSTALL 5 SINKS WITH WATER HEATER AND BATHROOM WITH 1 SINK AND 1 WATER CLOSET

  540. PermitMajor alteration

    Permit 481149 · COMPLETED

    TENANT FITOUT TO THE 11TH FLOOR AS PER PLANS. FOR ISSUANCE OF L.O. FOR LUNCHROOM.

  541. PermitMechanical

    Permit 477726 · COMPLETED

    FOR THE INSTALLATION OF DUCTWORK AND REGISTERR/DIFFUSERS. ALL WORK SHALL BE IN ACCORDANCE WITH APPROVED PLANS.

  542. PermitMajor alteration

    Permit 472775 · COMPLETED

    NEW OFFICE PARTITIONS, NEW ACOUSTICAL CEILINGS, GLASS OFFICE FRONTS, INTERCONNCECTING STRUCTURAL STAIR, NEW FINISHES AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  543. PermitSuppression

    Permit 478681 · COMPLETED

    RELOCATE (181) SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT WALL AND CEILING LAYOUTS AS PER ALL NFPA NO. 113 AND LOCAL CODES.

  544. PermitMechanical

    Permit 467615 · COMPLETED

    HVAC PER PLANS FOR OFFICE BUILDING.

  545. PermitPlumbing

    Permit 470169 · COMPLETED

    4 FIXTURES 1 DRINKING FOUNTAIN,2 WATER HEATERS,1 KITCHEN SINK ON THE 37TH FLOOR

  546. PermitElectrical

    Permit 466194 · COMPLETED

    ELECTRICAL WORK FOR TENANT FITOUT PROJECT AS PER DRAWINGS BY HPE GROUP DATED 3/20/13. INSTALL 7 SPEAKER /STROBE UNITS, INSTALL 2 ADDRESSABLE MODULES AND RELAYS. INSTALL 1 NAC EXTENDER PANEL AS PER NEC 2008 & NFPA 72 (COMM)

  547. PermitElectrical

    Permit 472062 · COMPLETED

    FURNISH AND INSTALL LOW VOLTAGE CAT 6 PLENUM CABLE FOR TELECOMMUNICATIONS PER 2008 NEC (OFFICE BLDG)

  548. PermitElectrical

    Permit 465094 · COMPLETED

    F&I MATERIAL & LABOR FOR THE INSTALLATION OF FIRE ALARM SYSTEM, FURNISH CONDUIT WHERE NEEDED AS PER 2008 NEC & NFPA 72 (OFFICE BLDG)

  549. PermitMajor alteration

    Permit 464999 · COMPLETED

    INTERIOR ALTERATIONS TO OFFICE SPACE.

  550. PermitMajor alteration

    Permit 465000 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING LOBBY ON THE 37TH FLOOR OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF A UNISEX ACCESSIBLE BATHROOM. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.

  551. PermitSuppression

    Permit 467664 · COMPLETED

    RELOCATE 27 SPRINKLERS IN THE HUB ON THE 2ND FLOOR AT TWO COMMERCE SQUARE

  552. PermitElectrical

    Permit 466190 · COMPLETED

    ELECTRICAL WORK FOR TENANT FITOUT PROJECT AS PER DRAWINGS BY HPE GROUP DATED 3/20/13 AS PER NEC 2008 (COMM)

  553. PermitSuppression

    Permit 466284 · COMPLETED

    RELOCATE (16) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE WALL AND CEILING LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES. CORRIDOR

  554. PermitSuppression

    Permit 466300 · COMPLETED

    RELOCATE (26) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW TENANT LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES. (TENANT SPACE)

  555. License issue eventCITIZENS BANK OF PENNSYLVANIA: Dumpster License - Private Property L&I license filing initially issued

    License 588924 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  556. PermitMechanical

    Permit 456367 · COMPLETED

    INTERIOR DEMO AND INSTALLATION OF 2 AHU, DUCT WORK, DIFFUSERS AND CONNECT TO EXISTING HVAC SYSTEM AS PER PLANSAND SPECIFICATIONS.

  557. PermitElectrical

    Permit 456766 · COMPLETED

    FURNISH & INSTALL INSTALLATION OF ELECTRICAL SYSTEM ACCORDANCE TO DRAWING FURNISH TELECOM WIRING & CABELE , FURNISH CONDUIT & BACK BOXES FOR TELECOM AS WELL, FURNISH ALL LIGHTING AS PER NEC 2008 (COMM)

  558. PermitElectrical

    Permit 457959 · COMPLETED

    INSTALL FIFTY CAT 5-E CABLES FOR COMPUTERS. WE WILL INSTALL IN ALL EXISTING CONDUIT AT PARTITION TABLES TO SERVER ROOM PATCH PANELS.

  559. PermitAdministrative

    Permit 394430 · COMPLETED

    LAWFUL OCCUPANCY OF 152 PEOPLE FOR PATRON SEATING.

  560. PermitPlumbing

    Permit 456364 · COMPLETED

    FURNISH AND INSTALL DRAIN, WATER AND VENT CONNECT TO EXISTING CONNECTION 1 SUMP PUMP, 2-SS SINKS AND 1 HOT WATER HEATER

  561. PermitSuppression

    Permit 455159 · COMPLETED

    RELOCATE 87 FIRE SPRINKLERS

  562. PermitMajor alteration

    Permit 452466 · COMPLETED

    FOR ALTERATIONS WITH NO CHANGE IN OCCUPANCY CLASSIFICATION @ ONE (1) STORY TENANT SPACE WITHIN AN EXISTING HIGH-RISE MIXED-USE OFFICE BUILDING TO INCLUDE ERECTION OF INTERIOR PARTITIONS FOR OPEN OFFICE, RECEPTION, EMPLOYEE LOUNGE, & CONFERENCE ROOM SPACES, INSTALLATION OF CASEWORK & CABINETRY, & INSTALLATION OF GLASS PARTITION WALLS; BUILDING IS FULLY SPRINKLERED. NO CHANGE IN WINDOW UNITS OR EXTERIOR OPENINGS PERMITTED HEREIN.

  563. PermitSuppression

    Permit 451892 · COMPLETED

    RELOCATE (14) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT WALL AND CEILING LAYOUT AS PER ALL NFPA NO. 13 AND LOCAL CODES ON 2ND FLOOR.

  564. PermitMechanical

    Permit 450481 · COMPLETED

    FOR THE EXTENSION OF EXISTING HVAC SYSTEM TO INCLUDE INSTALLATION OF (11) HVAC TERMINAL GRILLES/REGISTERS/DIFFUSERS (GRDS), TERMINAL VARIABLE AIR VOLUME (VAV) FAN BOXES @ CEILING, & ALL ASSOCIATED SUPPLY/ RETURN/ EXHAUST DUCTWORK FOR TIE-IN TO EXIST. HVAC SYSTEM SERVING ONE (1) STORY TENANT SPACE WITHIN EXISTING MIXED-USE HIGHRISE BUILDING.

  565. PermitElectrical

    Permit 448898 · COMPLETED

    REMOVE AND RELOCATE 8 RECEPTACLES AND (12) 1X4 LIGHTS PER 2008 NEC (COMMERCIAL)

  566. PermitPlumbing

    Permit 446802 · COMPLETED

    INSTALL A PANTRY SINK

  567. PermitPlumbing

    Permit 446804 · COMPLETED

    INSTALLATION OF (2) PANTRY SINKS

  568. License terminal eventTWO COMMERCE SQ MARATHON GRILL: Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 209071 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  569. PermitElectrical

    Permit 440465 · COMPLETED

    FURNISH AND INSTALL 5 SPEAKER/STROBES 9 STROBES 3 ZAMS 1 NAC PANEL PER 2008 NEC & NFPA 72 (OFFICE SPACE)

  570. PermitAdministrative

    Permit 443297 · COMPLETED

    AMEND PREVIOUSLY ISSUED PERMIT # 428298 TO CHANGE ADDRESS TO 2001 MARKET ST

  571. PermitMechanical

    Permit 436355 · COMPLETED

    HVAC TO INCLUDE DUCTWORK AND MECHANICAL EQUIPMENT AND (19) REGISTERS/DIFFUSERS AS PER PLANS.

  572. PermitElectrical

    Permit 432567 · COMPLETED

    FURNISH AND INSTALL NEW FIR ALARM DEVICES PER 2008 NEC & NFPA 72 (OFFICE SPACE)

  573. PermitElectrical

    Permit 436721 · COMPLETED

    TONE OUT,TEST,TAG EXISTING LOW VOLT CABLES AND RETERMINATE ON PATCH PANELS.PANELS WILL BE ON A NEW 2 POST RACK AND ARE RATED CAT5E.PLENUM RATED CAT 5E CABLE WILL BE RETERMINATED AND IS THE EXISTING CABLE AS PER 2008 NEC(OFFICES)

  574. PermitElectrical

    Permit 436703 · COMPLETED

    INSTALLING BURG ALARM AND CAMERA'S TO AREA CUST # 080-026117 -01 - 02 -03.

  575. PermitElectrical

    Permit 430899 · COMPLETED

    FURNISH 6 ADDITIONAL FIRE ALARM SPEAKER/STROBES FOR LOCATIONS IN OFFICE BLDG LOBBY, WIRING OF ADDED SPEAKER/STROBES IN ACCORDANCE WITH SIMPLEX GRINNELL DRAWING PER 2008 NEC & NPFA 72 (OFFICE SPACE)

  576. PermitSuppression

    Permit 435592 · COMPLETED

    RELOCATING 21 SPRINKLERS IN COHEN PLACITELLA SPACE ON 29TH FLOOR OF TWO COMMERCE SQUARE

  577. PermitSuppression

    Permit 435593 · COMPLETED

    RELOCATING 21 SPRINKLERS IN HARKINS CUNNINGHAM SPACE 40TH FLOOR OF TWO COMMERCE SQUARE

  578. PermitElectrical

    Permit 430773 · COMPLETED

    FURNISH AND INSTALL NEW LIGHTING AND RECEPTACLES IN THE EXISTING EAST PER 2008 NEC (OFFICE SPACE)

  579. PermitMajor alteration

    Permit 432751 · COMPLETED

    FOR INTERIOR ALTERATIONS AS PER PLANS.

  580. PermitPlumbing

    Permit 432155 · COMPLETED

    INSTALLATION OF A KITCHEN SINK

  581. PermitMechanical

    Permit 430561 · COMPLETED

    FOR THE INSTALLATION OF THREE (3) TERMINAL FAN BOXES, ONE (1) WATER SOURCE HEAT PUMP, (21) HVAC TERMINAL GRILLES/REGISTERS/DIFFUSERS (GRDS), & ALL ASSOCIATED SUPPLY/RETURN/EXHAUST DUCTWORK FOR TIE-IN TO EXISTING WARM AIR HVAC SYSTEM; DEMOLITION WORK & ALTERATION TO EXISTING SYSTEM BRANCHES LIMITED TO APPROVED PLANS.

  582. PermitSuppression

    Permit 431524 · COMPLETED

    RELOCATE (17) EXISTING SPRINKLER HEAD - 5TH FLR.

  583. PermitMajor alteration

    Permit 430383 · COMPLETED

    INTERIOR ALTERATIONS FOR NON LOAD BEARING PARTITIONS AS PER SEALED SUBMITTED PLANS. ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE SUPPRESSION WORK REQUIRES ADDITIONAL PERMITS. FIRE RATED ASSEMBLIES ARE REQUIRED TO BE MAINTAINED AT ALL TIMES. CALL THE INSPECTOR PRIOR TO STARTING WORK.

  584. PermitDemolition

    Permit 429542 · COMPLETED

    INTERIOR DEMOLITION OF NON LOAD BEARING PARTITIONS

  585. PermitElectrical

    Permit 424569 · COMPLETED

    FIRE ALARM- 3 S/S'S, 1 STROBE, 1 NAC PANEL AS PER 2008 NEC & NFPA 72 (OFFICE BLDG)

  586. PermitMechanical

    Permit 423115 · COMPLETED

    HVAC, INCLUDING DUCTWORK, 14 REGISTERS/DIFFUSERS ON THE GROUND FLOOR OFFICE AS PER PLANS.

  587. PermitElectrical

    Permit 424288 · COMPLETED

    REPLACE 35 FIXTURES W/LED, ADD DUPLEX RECEPTACLES, PROVIDE POWER TO BAR EQUIPMENT PER 2008 (COMMERCIAL)

  588. InvestigationCI INSP

    Case 319230 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  589. InvestigationCI INSP

    Case 319230 · CLOSED

    City marked the record closed; open the case for the closing reason.

  590. PermitMajor alteration

    Permit 417281 · COMPLETED

    INTERIOR ALTERATIONS TO EXISTING RESTAURANT AS PER PLANS.

  591. PermitPlumbing

    Permit 420863 · COMPLETED

    FURNISH AND INSTALL PANTRY SINK, 4 SHAMPOO SINKS WITH HAIR TRAP(HAIR SALON)

  592. PermitElectrical

    Permit 420272 · COMPLETED

    REWORK LIGHTING LAYOUT, FURNISH AND INSTALL 30 DUPLEX RECEPTACLES 2 EXITS 4 OCC SENSORS AND 1 POKETHRU PER 2008 NEC

  593. PermitUse

    Permit 418949 · COMPLETED

    FOR A HAIR SALON ON GROUND FLOOR IN SAME BUILDING WITH USES AS PERVIOUSLY APPROVED.

  594. PermitMajor alteration

    Permit 417359 · COMPLETED

    RETAIL FIT OUT AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING.

  595. License terminal eventREAL FRESH INC (PAGANO'S MARKET): Dumpster License - Private Property L&I license filing marked inactive

    License 558196 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  596. PermitSuppression

    Permit 419024 · COMPLETED

    RELOCATE 12 EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE NEW TENANT FIT-OUT AS PER ALL NFPA NO. 13 AND LOCAL CODES.

  597. PermitElectrical

    Permit 411277 · COMPLETED

    ADD 1 NEW FIRE ALARM DEVICE, RELOCATE 2 FIRE ALARM DEVICES PER 2008 NEC & NFPA 72

  598. PermitElectrical

    Permit 409972 · COMPLETED

    5 SPEAKER STROBES AND 3 STROBES AS PER NFPA-72(HIGH RISE-OFFICE BLDG)(CC DIST)

  599. PermitElectrical

    Permit 405894 · COMPLETED

    REPLACEMENT OF OWNER FURNISHED LOBBY AND ENTRANCE WAY LIGHTING AND CONTROLS AS PER 2008 NEC (CC DIST) OFFICE BLDG

  600. PermitMechanical

    Permit 407122 · COMPLETED

    HVAC INCLUDING DUCTWORK AS PER PLANS. 41 REGISTERS-OFFICE BLDG

  601. PermitPlumbing

    Permit 411350 · COMPLETED

    39TH FLOOR - INTERIOR ALTERATIONS (PLUMBING) - UNI-SEX TOILET ROOM - (1)WATER CLOSET, (1)LAVATORY AND (1)DRINKING FOUNTAIN

  602. PermitElectrical

    Permit 411244 · COMPLETED

    36 VOICE DATA LINES CAT 6 PLENUM RATED WIRE AS PER NEC 2008 (OFFICE)

  603. PermitSuppression

    Permit 410518 · COMPLETED

    RELOCATE 16 SPRINKLER HEADS - 39TH FLOOR

  604. PermitElectrical

    Permit 408804 · COMPLETED

    1 OCCUPANCY SENSOR, 1 HOT WATER HEATER FEED, 2 GFI RECEPTACLES 1 EXHAUST FAN FEED, 40 LIGHT FIXTURE CONNECTIONS AND 2 SINGLE POLE PER 2008 NEC

  605. PermitSuppression

    Permit 408543 · COMPLETED

    RELOCATE 50 SPRINKLERS ON THE 39TH FLOOR: KAUFMAN, COREN & RESS SPACE OF TWO COMMERCE SQUARE

  606. PermitMajor alteration

    Permit 407263 · COMPLETED

    COMMON CORRIDOR / ELEVATOR LOBBY RENOVATION AND ADDITION OF ACCESSIBLE UNI-SEX TOILET ROOM.ON 39TH FLOOR

  607. PermitElectrical

    Permit 407207 · COMPLETED

    30 DUPLEX RECEPTABLES, 3 QUADS, 10 OCCUPANCY SENSORS, 30 TELE/DATA STUBS, POWER DISHWASHER, POWER HOT WATER HEATER, REMOVE & RELOCATE 30 DOWNLIGHTS, 5 EXITS AS PER NEC 2008

  608. PermitMajor alteration

    Permit 403902 · COMPLETED

    INTERIOR RENOVATIONS, UPGRADES TO FINISHES, NON LOAD BEARING PARTITIONS, PATCH/REPAIR ACOUSTICAL CEILING, NEW FLOOR CONFIGURATON FOR EXISTING OFFICE SPACE AS PER PLANS FOR THE 39TH FLOOR. NO CHANGE IN USE - OCCUPANCY CLASSFICATION. ADD'L PERMITS REQ: ELECTRICAL, PLUMBING, HVAC SPRINKLERS.

  609. PermitPlumbing

    Permit 404804 · COMPLETED

    GROUND FLOOR LOBBY & PLAZA - LOBBY RENOVATIONS (PLUMBING) - (6)PLANTER DRAINS

  610. InvestigationCI INSP

    Case 319230 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  611. PermitMajor alteration

    Permit 398862 · COMPLETED

    INTERIOR RENOVATION OF EXISTING SPACE TO CREATE NEW OFFICES AS PER PLAN.

  612. InvestigationCI INSP

    Case 321104 · PASSED

    The cited inspection visit was marked passed.

  613. PermitMechanical

    Permit 397070 · COMPLETED

    RELOCATE 14 DIFFUSERS

  614. ViolationVIOL C&I MESSAGE

    Case 321104 · Violation 2396058 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  615. ViolationFA-MONITORING COMPANY

    Case 321104 · Violation 2396059 · Code FC-907.15/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  616. InvestigationCI INSP

    Case 321104 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  617. PermitSuppression

    Permit 394622 · COMPLETED

    RELOCATE 4 SPRINKLER HEADS - 17TH FLOOR

  618. License issue eventREAL FRESH INC (PAGANO'S MARKET): Dumpster License - Private Property L&I license filing initially issued

    License 558196 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  619. PermitElectrical

    Permit 392167 · COMPLETED

    FURNISH AND INSTALL 1 QUAD REC, 1 VOICE/DATA, 2 TASK LIGHTS AT LOBBY DESK AS PER 2008 NEC(COMMERCIAL)(CC DIST)

  620. ViolationVIOL C&I MESSAGE

    Case 319230 · Violation 2551302 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  621. ViolationEGRESS-ASSEM OCC SIGNS

    Case 319230 · Violation 2551299 · Code FC-1004.3/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  622. ViolationFIRE-COMM KITCH EXHAUST CLEAN

    Case 319230 · Violation 2551300 · Code FC-904.11/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  623. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 319230 · Violation 2551301 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  624. InvestigationCI INSP

    Case 319230 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  625. InvestigationCI INSP

    Case 300984 · PASSED

    The cited inspection visit was marked passed.

  626. InvestigationCI INSP

    Case 300984 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  627. PermitMajor alteration

    Permit 381058 · COMPLETED

    RENOVATION OF THE LOBBY AND PLAZA SPACE. SEE AP#381059,2005 MARKET STREET, FOR PLANS

  628. PermitMajor alteration

    Permit 384231 · COMPLETED

    INSTALLATION OF A DESK IN THE EXISTING LOBBY OF A HIGH RISE BUILDING AS PER THE SUBMITTED PLAN. ELECTRICAL WORK WILL REQUIRE AN ADDITIONAL PERMIT. CALL THE INSPECTOR PRIOR TO STARTING WORK.

  629. PermitZoning/use

    Permit 363678 · COMPLETED

    FOR THE ERECTION OF (25) SIGNS TO AN EXISTING STRUCTURE, SIZE AND LOCATION AS SHOWN IN APPLICATION. SIGNS ACCESSORY TO EXISTING STRUCTURE AND FOR SEVERAL EXISTING TENANTS.

  630. PermitMajor alteration

    Permit 373330 · COMPLETED

    EXTERIOR ALTERATIONS TO EXISTING PLAZA. INCLUDES INSTALLATION OF PRECAST CONCRETE SITE FURNISHING, WATERPROOFING, ROOF IMPROVEMENTS OVER UNDERGROUND SPACE, AND PREPARATION FOR PLUMBING WORK. SEPARATE PLUMBING PERMITS REQUIRED.

  631. License issue eventFEDEX KINKOS OFFICE AND PRINT SVCS INC: Dumpster License - Private Property L&I license filing initially issued

    License 550636 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  632. InvestigationCI INSP

    Case 300984 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  633. PermitMechanical

    Permit 376697 · COMPLETED

    RELOCATE (6) DIFFUSERS

  634. PermitSuppression

    Permit 376604 · COMPLETED

    RELOCATE 4 SPRINKLER HEADS ON 26TH FLOOR

  635. AppealZoning board appeal

    Appeal 16475 · CLOSED · Granted with conditions

    Related permit 363678 · PERMIT FOR THE ERECTION OF (25) SIGNS ACCESSORY TO AN EXISTING STRUCTURE AND FOR SEVERAL TENANTS WITHIN SAID STRUCTURE.

  636. PermitElectrical

    Permit 371937 · COMPLETED

    FURNISH AND INSTALL LIGHTING AND POWER THRU-OUT SPACE TO MEET CODE, S PER 2008 NEC, OFFICE SPACE

  637. PermitElectrical

    Permit 371005 · COMPLETED

    DISCONNECT AND RECONNET A/C UNITS ON ROOF AS PER 2008 NEC (CC DIST)(COMMERCIAL OFFICE SPACE)

  638. PermitPlumbing

    Permit 367481 · COMPLETED

    INTERIOR ALTERATIONS (PLUMBING) - 6TH AND 7TH FLOORS - (2)UNI-SEX TOILET ROOMS - (2)WATER CLOSETS AND (2)LAVATORIES

  639. PermitPlumbing

    Permit 367478 · COMPLETED

    INTERIOR ALTERATIONS (PLUMBING) - 8TH FLOOR - (1)WATER CLOSET AND (1)LAVATORY

  640. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 300984 · Violation 2361299 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  641. ViolationEGRESS-ASSEM OCC SIGNS

    Case 300984 · Violation 2361297 · Code FC-1004.3/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  642. ViolationVIOL C&I MESSAGE

    Case 300984 · Violation 2361296 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  643. ViolationFIRE-COMM KITCH EXHAUST CLEAN

    Case 300984 · Violation 2361298 · Code FC-904.11/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  644. InvestigationCI INSP

    Case 300984 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  645. PermitSuppression

    Permit 362307 · COMPLETED

    RELOCATE 21 SPRINKLER HEADS (6TH, 7TH, & 8TH FLOORS)

  646. PermitMajor alteration

    Permit 353297 · COMPLETED

    INTERIOR FITOUT WORK AS PER PLANS.

  647. PermitMechanical

    Permit 353648 · COMPLETED

    HVAC INSTALLATION INCLUDES DUCT WORK, REGISTERS, DIFFUSER AND CONTROLS.

  648. PermitAlteration

    Permit 358456 · COMPLETED

    REMOVE AND SAVE EXISTING PAVERS TEAR OF TO DECK MECHANICALLY ATTACH PARABASE FS REINSTALL EXISTING PAVERS

  649. PermitMajor alteration

    Permit 356935 · COMPLETED

    INTERIOR ALTERATIONS FOR THE ADDITION OF TWO NEW UNISEX ADA TOILETS, ONE AT 6TH FLOOR LEVEL AND ONE AT 7TH FLOOR LEVEL.

  650. PermitMajor alteration

    Permit 352943 · COMPLETED

    FOR INTERIOR ALTERATIONS TO INCLUDE FRAMING, INSTALLATION OF WALLBOARD FOR 8TH FLOOR LOBBY, CORRIDORS AND BATHROOMS INCLUDING ACCESSIBILITY BATHROOM WITHIN EXISTING OFFICE BUILDING AS PER PLANS.

  651. PermitPlumbing

    Permit 355234 · COMPLETED

    31ST FLOOR - FURNISH AND INSTALL (1)SINK - CONNECT TO EXISTING SERVICES

  652. PermitMechanical

    Permit 341961 · COMPLETED

    INSTALL DUCTWORK, PIPING AND RELATED MECHANICALS.

  653. PermitMechanical

    Permit 337716 · COMPLETED

    FOR THE PARTIAL DEMOLITION OF EXISTING DUCTS AND FOR THE INSTALLATION OF NEW DUCTWORK, DIFFUSERS, AIR DEVICES, EXHAUST FAN AND RELATED MECHANICAL EQUIPMENT WITHIN EXISTING OFFICE AS PER PLANS.

  654. PermitSuppression

    Permit 343206 · COMPLETED

    RELOCATE 5 SPRINKLER HEADS (24TH FLOOR)

  655. PermitElectrical

    Permit 331594 · COMPLETED

    INSTALL 40 CAT6 PLENUM CABLES IN THE TRAINING ROOM, ALL CABLING WILL BE INSTALLED IN J-HOOKS, ALL SLEEVES WILL BE FIRE STOPPED AS PER 2008 NEC

  656. PermitAdministrative

    Permit 326838 · COMPLETED

    FOR AN AMENDED PERMIT ACTIVITY DEPICTING ANSI 117.1 2003 ACCESSIBILTY COMPLIANCE FOR THE RENOVATED PANTRY AREAS. THIS WORK SCOPE IS PART OF THE PARENT PERMIT #302762 FOR ALTERATIONS TO THE 9TH & 10TH FLRS.

  657. PermitElectrical

    Permit 322046 · COMPLETED

    ADD ADDITION OF POWER DEVICES AND REMOVE AND RELOCATE LIGHTS ADD EXITS AS PER 2008 NEC

  658. PermitElectrical

    Permit 320042 · COMPLETED

    REMOVE AND REPLACE LIGHTING FIXTURES IN RECEPTION AREAS,EXISTING CIRCUITRY TO BE REUSED AND CONNECTED TO NEW LIGHTING FIXTURES,RELOCATION OF FIRE ALARM SPEAKERS WITH NO NEW WIRING AS PER 2008 NEC

  659. PermitSuppression

    Permit 321314 · COMPLETED

    RELOCATE 15 EXISTING SPRINKLER HEADS(COMMERCIAL)

  660. PermitSuppression

    Permit 321326 · COMPLETED

    RELOCATE 29 EXISTING SPRINKLER HEADS(COMMERCIAL)

  661. PermitMechanical

    Permit 318650 · COMPLETED

    HVAC, INCLUDING DUCTWORK FOR OFFICE BLDG.

  662. PermitPlumbing

    Permit 319745 · COMPLETED

    REMOVE (2) EXISTING BREAK ROOM SINKS ON FLOOR #10 AND REPLACE WITH NEW SINK AND TRIM, REMOVE 1 EXISTING BREAK ROOM SINK ON FLOOR #9 AND REPLACE WITH NEW SINK AND TRIM

  663. PermitMajor alteration

    Permit 316783 · COMPLETED

    REPLACE FINISHES ON 17TH FLOOR RECEPTION AREA, ELEVATOR LOBBY, AND COMMON AREAS; REPLACE FINISHES IN COMMON AREAS ON FLOORS 18 TO 23; CREATE TWO OFFICES ON 20TH FLOOR; CREATE A PROFESSIONAL SPACE ON 22ND FLOOR;

  664. PermitElectrical

    Permit 318582 · COMPLETED

    INSTALL 25 CAT 5E CABLES.

  665. PermitMechanical

    Permit 314010 · COMPLETED

    RELOCATE (2) DIFFUSERS FOR OFFICE.

  666. PermitElectrical

    Permit 310092 · COMPLETED

    REMOVE AND RELOCATE 10 1X5 FIXTURES, REMOVE AND RELOCATE 2 FURNITURE FEEDS,REMOVE AND RE INSTALL 10 DUPLEX RECEPTACLES,10 T/O STUB UPS AS PER 2008 NEC

  667. PermitSuppression

    Permit 308717 · COMPLETED

    RELOCATE 12 EXISTING SPRINKLER HEADS(COMMERCIAL)

  668. License terminal eventCLEMENT CIZEWSKI (MODERN_RESTAURANTS): Dumpster License - Private Property L&I license filing marked inactive

    License 278716 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  669. PermitMajor alteration

    Permit 302762 · COMPLETED

    FOR INTERIOR ALTERATION WITHIN EXISTING TENANT SPACES ON THE 9TH & 10TH FLOORS. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. APPLICANT / CONTRACTOR SHALL SUBMIT AN AMENDED PERMIT DEPICT ANSI 117.1 2003 ACCESSIBILTY COMPLIANCE FOR THE RENOVATED PANTRY AREAS.

  670. PermitMechanical

    Permit 300219 · COMPLETED

    RELOCATE 4 DIFFUSERS

  671. PermitElectrical

    Permit 293525 · COMPLETED

    RENOVATION OF EXISTING MAIL ROOM INCLUDING NEW LIGHT FIXTURES, RECEPTACLES AND LIGHT SWITCH. REINSTALL EXISTING FIRE ALARM SPEAKER/ STROBE IN NEW CEILING TILE.

  672. PermitMajor alteration

    Permit 297494 · COMPLETED

    INTERIOR ALTERATIONS PER PLANS

  673. PermitElectrical

    Permit 297729 · COMPLETED

    FURNISH AND INSTALL (8-10)CATEGORY 6 PLENUM CABLES- LONGEST RUN 125 FEET.... IN ACCORDANCE WITH 2008 NEC

  674. PermitSuppression

    Permit 298352 · COMPLETED

    RELOCATE 4 SPRINKLER HEADS(COMMERCIAL)

  675. License issue eventCOMMERCE DUJOUR CORP INC: Dumpster License - Private Property L&I license filing initially issued

    License 511777 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  676. PermitSuppression

    Permit 294608 · COMPLETED

    RELOCATE (6) SPRINKLERS IN P1 BASEMENT OF BUILDING IN THE MAIL/SCANNING RESEARCH ROOM.

  677. PermitMajor alteration

    Permit 292039 · COMPLETED

    FOR THE CONSTRUCTION OF TWO PARTITIONS TO CREATE OFFICE. INSTALLATION OF DOOR UNIT AND COUNTERTOP AS PER PLANS.

  678. PermitElectrical

    Permit 276795 · COMPLETED

    MAKING A STORAGE AREA INTO A CHANGING & SHOWER AREA WITH NEW LIGHT FIXTURES,SWITCHES,RECEPTACLES & HVAC POWER. BRANCH CIRCUITS FROM EXISTING PANELS. FIRE ALARM UNDER SEPARATE PERMIT AS PER 2008 NEC (CC DISTRICT)

  679. InvestigationBC INSP (likely: building-code inspection)

    Case 53094 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  680. PermitElectrical

    Permit 281125 · COMPLETED

    RELOCATE (2) STROBES & (1) SPEAKER/STROBE

  681. PermitElectrical

    Permit 281129 · COMPLETED

    INSTALL (2) WALL PHONES, INSTALL WIRING FOR SECURITY ON (2) DOORS

  682. PermitMechanical

    Permit 277812 · COMPLETED

    INSTALL DUCT, DIFFUSERS

  683. PermitPlumbing

    Permit 277048 · COMPLETED

    17 FIXTURES WITH PIPING FOR BATHROOMS ON P-1 LEVEL(PARKING GARAGE)AS PER PLANS

  684. PermitMajor alteration

    Permit 274038 · COMPLETED

    INTERIOR ALTERATIONS TO CONSTRUCT SHOWER AND LOCKER ROOMS AS PER PLANS

  685. InvestigationCI INSP

    Case 225851 · PASSED

    The cited inspection visit was marked passed.

  686. ViolationFIRE EXTING-NEEDS INSP/TAG (Fire extinguisher needs inspection and a current service tag)

    Case 225851 · Violation 1582500 · Code FC-906.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  687. ViolationVIOL C&I MESSAGE

    Case 225851 · Violation 1582497 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  688. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 225851 · Violation 1582499 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  689. ViolationFIRE-COMM KITCH EXHAUST CLEAN

    Case 225851 · Violation 1582498 · Code FC-904.11/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  690. InvestigationCI INSP

    Case 225851 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  691. PermitFast form building

    Permit 255574 · COMPLETED

  692. License issue eventCOMMERCE DU JOUR CORP: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 490721 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  693. PermitAdministrative

    Permit 254812 · COMPLETED

    THIS PERMIT IS TO AMEND THE ADDRESS FROM AP#201912 FROM 2120 MARKET ST TO THE CORRECT ADDRESS OF 2001 MARKET ST.TOO INCLUDE CERTIFICATE OF OCCUPANCY

  694. PermitPlumbing

    Permit 253199 · COMPLETED

  695. PermitMechanical

    Permit 250638 · COMPLETED

    HVAC, INCLUDING DUCTWORK, AS PER PLANS

  696. PermitFast form building

    Permit 250442 · COMPLETED

  697. PermitZoning/use

    Permit 244499 · COMPLETED

    FOR THE REPLACE FACE OF AN EXISTING FOUR(4) WINDOW SIGNS , FOR THE REMOVAL OF TWO(2) AN EXISTING WINDOW VINYL SIGNS AND FOR THE ERECTION OF TWO(2) WINDOW VINYL SIGNS.SIZE AND LOCATION AS SHOWN IN THE APPLICATION. FOUR(4) SF WINDOW SIGNS AND FOR THE REMOVAL OF TWO(2) VINYL SIGNS AND FOR THE ERECTION OF ONE(1) DOOR AND ONE (1) WINDOW VINYL SIGN. SIZE AND LOCATION AS SHOWN IN THE APPLICATION. SIGN ACCESSORY TO AN EXISTING DUPLICATING COPY CENTER, PRINTING, PUBLISHING AND RELATED TRADES AS PART OF AN EXISTING STRUCTURE WITH ALL OTHER USES AS PREVIOUSLY APPROVED.

  698. PermitElectrical

    Permit 222899 · COMPLETED

    INSTALLATION OF CABINET, ELECTRONICS, OUTLET AND INNER DUCT FOR FUTURE USE, THIS WORK IS DONE FOR COGENT COMMUNICATIONS, THIS ALSO INCLUDES THE INSTALLATION OF 2" CONDUIT TO 2 LOCATIONS IN THE BUILDING AS PER 2005 (CC DISTRICT)

  699. PermitMechanical

    Permit 219085 · COMPLETED

    INSTALL TWO (2) COMMERCIAL KITCHEN EXHAUST HOODS TIED INTO THE EXISTING DUCTWORK AS PER PLANS.

  700. PermitSuppression

    Permit 221474 · COMPLETED

    INSTALL ANSUL SUPPRESSION SYSTEM AND ACCESSORIES FOR TWO (2) COMMERCIAL KITCHEN EXHAUST HOODS TIED INTO THE EXISTING DUCTWORK AS PER PLANS. W/ AP 219085

  701. PermitElectrical

    Permit 211555 · COMPLETED

    ADD (17) SPEAKER/STROBES, ADD (7) STROBES, ADD (3) DUCT DETECTORS, ADD (1) SMOKE DETECTOR, R & R (2) PULL STATIONS, AS PER NFPA-72 (CC DIST)

  702. PermitElectrical

    Permit 203359 · COMPLETED

    (150) DUPLEX RECEPTACLES, (35) OCCUPANCY SENSORS, (12)_ QUAD RECEPTACLES, (5) SINGLE POLE SWITCHES, (20) L5-30R, (7) GFI'S, (127) NEW LIGHT FIXTURES, (95) REMOVE AND RELOCATE 1 X 5 FIXTURES, AS PER 2005 NEC (CC DIST)

  703. License issue eventPHILADELPIHA PLAZA PHASE II AKA COMMERCE SQ (EXPERT PARKING): Public Garage / Parking Lot business license initially issued

    License 469560 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  704. InvestigationBC INSP (likely: building-code inspection)

    Case 195995 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  705. PermitSign

    Permit 205449 · COMPLETED

    ERECT 2 FLATWALL SIGNS AS PER PLANS.

  706. PermitUse

    Permit 197815 · COMPLETED

    FOR A REDUCTION OF ACCESSORY / PUBLIC "CROSS EASEMENT" PARKING FOR BOTH LOTS ( 2001 MARKET ST. BRT# 883054361 & 2005 MARKET ST. BRT# 883054371 )FOR A TOTAL OF (514) COMBINED PARKING SPACES, NO SIGNS ON THIS APPLICATION.

  707. PermitElectrical

    Permit 191869 · COMPLETED

    (56) DUPLEX RECEPTACLES, (25) OCCUPANCY SENSORS, (4) FURNITURE FEEDS, (14) DOWNLIGHTS, (10) 1 X 5 FIXTURES AS PER 2005 NEC (CC DIST)

  708. PermitPlumbing

    Permit 194168 · COMPLETED

    RELOCATE EXISTING SINK, INSTALL NEW HOT AND COLD WATER LINES

  709. PermitMechanical

    Permit 191554 · COMPLETED

    DEMO & REMOVAL OF EXISTING SYSTEM & INSTALLATION OF NEW HVAC SYSTEM, ACCESSORY MECHANICALS, DUCTWORK, AS PER PLANS

  710. PermitElectrical

    Permit 179522 · COMPLETED

    INSTALLATION OF CATEGORY 5E VOICE CABLE, CAT 6 DATA CABLE 200 PAIR RISER CABLES AS PER 2005 NEC (CC DISTRICT)

  711. PermitElectrical

    Permit 186116 · COMPLETED

    INSTALL 10 NEW SPEAKER/STROBES.

  712. License issue eventREAL FRESH INC (PAGANO'S MARKET): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 461915 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  713. PermitZoning/use

    Permit 183901 · COMPLETED

    FOR THE ERECTION OF TWO (2) INTERNALLY ILLUINATED, FLATWALL SIGNS ON AN EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION. FOR THE RENTAL OF FURNITURE IN THE SAME BUILDING WITH USES AS PREVIOUSLY APPROVED.

  714. PermitFast form building

    Permit 183166 · COMPLETED

  715. PermitElectrical

    Permit 177971 · COMPLETED

    REMOVE AND RELOCATE 19 1X5 FIXTURES, ADD 10 NEW DUPLEX RECEPTS RE USE ALL EXISTING CIRCUITRY FROM DEMO AS PER 2005 NEC (CC DISTRICT)

  716. PermitElectrical

    Permit 177970 · COMPLETED

    REMOVE AND RELOCATE 72 1X5 FIXTURES, ADD 88 DUPLEX RECEPTS, 24 MOTION SENSORS, 64 GFI RECEPTS, REMOVE & RELOCATE 100AMP PANEL AS PER 2005 NEC (CC DISTRICT)

  717. PermitPlumbing

    Permit 181815 · COMPLETED

    FIXTURE INSTALLATION

  718. PermitMechanical

    Permit 180101 · COMPLETED

    RELOCATE (12) DIFFUSERS. FOR OFFICE BUILDING

  719. PermitElectrical

    Permit 177906 · COMPLETED

    INSTALL VOICE AND DATA CABLE CAT5E TYPE LONGEST LENGTH OF CABLE 100'. 17 CABLE LOCATIONS. SECO #9518 (CC DIST)

  720. PermitFast form building

    Permit 177634 · COMPLETED

  721. PermitPlumbing

    Permit 177211 · COMPLETED

    INSTALLATION OF PANTRY SINK

  722. PermitElectrical

    Permit 170827 · COMPLETED

    INSTALL 70 CAT5E PLENUM CABLES LONGEST RUN 140" AS PER 2005 NEC (CC DISTRICT)

  723. PermitMechanical

    Permit 168202 · COMPLETED

    HVAC INCLUDING DUCTWORK

  724. PermitPlumbing

    Permit 176425 · COMPLETED

    FIXTURE INSTALLATION

  725. PermitMajor alteration

    Permit 173591 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLAN TO INCLUDE MECHANICAL

  726. PermitElectrical

    Permit 168505 · COMPLETED

    INSTALL (10) NEW DUPLEX RECEPTACLES, INSTALL (16) 4' LENGTHS OF TRACK LIGHTING. DEMO OLD TRACK LIGHTS, RE-LAMP EXISTING FIXTURES, RE-USE ALL EXISTING CIRCUITRY, AS PER 2005 NEC (CC DIST)

  727. PermitSuppression

    Permit 168573 · COMPLETED

    INSTALL KITCHEN FIRE SUPPRESSION SYSTEM

  728. PermitMajor alteration

    Permit 167090 · COMPLETED

    TENANT FIT-OUT, AS PER PLANS.

  729. PermitElectrical

    Permit 155636 · COMPLETED

    INSTALL (70) NEW RECEPTACLES, (5) FURNITURE POWER FEEDS, (2) GFI RECEPTACLES, (25) OCCUPANCY SENSORS, (80) NEW LIGHTS, (65) RELOCATED LIGHTS, (15) EXIT SIGNS, AS PER 2005 NEC. NO FIRE ALARM (CC DIST)

  730. PermitFast form building

    Permit 164208 · COMPLETED

  731. PermitPlumbing

    Permit 163709 · COMPLETED

    INSTALLATION OF WATER CLOSET, LAVATORY

  732. PermitMajor alteration

    Permit 154125 · COMPLETED

    RENOVATIONS PER SUBMITTED SEALED PLANS. ONE DIRECT EXIT FROM THE SPACE IS REQUIRED. C.O.

  733. PermitSuppression

    Permit 153959 · COMPLETED

    INSTALL (FIKE HFC-125 CLEAN AGENT)SUPPRESSION SYSTEM

  734. PermitElectrical

    Permit 156634 · COMPLETED

    INSTALL CABLE, PANEL AND DEVICES FOR FIRE SUPPRESSION SYSTEM ACCORDING TO NFPA-72 (CC DIST)

  735. PermitMechanical

    Permit 158474 · COMPLETED

    RELOCATE (15) DIFFUSERS TENANT-AKINS GUMP

  736. PermitFast form building

    Permit 158707 · COMPLETED

  737. PermitNew Construction

    Permit 157169 · Expired

    RENOVATION TO EXISTING TENANT SPACE: RELOCATE (4) LIGHT FIXTURES (1) EXIT SIGN, INSTALL (4) RECEPTACLES, (1) WALL FURNITURE FEED, (1) WALL SWITCH, RE-USE EXISTING CIRCUITS, NO ANTICIPATED CHANGE IN LOAD, ALL AS PER 2005 NEC (CC DIST) RENOVATION TO EXISTING TENANT SPACE: RELOCATE (4) LIGHT FIXTURES (1) EXIT SIGN, INSTALL (4) RECEPTACLES, (1) WALL FURNITURE FEED, (1) WALL SWITCH, RE-USE EXISTING CIRCUITS, NO ANTICIPATED CHANGE IN LOAD, ALL AS PER 2005 NEC (CC DIST)

  738. PermitMajor alteration

    Permit 152844 · COMPLETED

    INTERIOR ALTERATIONS PER PLANS.

  739. PermitFast form building

    Permit 153692 · COMPLETED

  740. PermitMajor alteration

    Permit 150407 · COMPLETED

    RENOVATIONS TO EXISTING OFFICE SPACE

  741. PermitElectrical

    Permit 131471 · COMPLETED

    SIXTY-SIX (66) VOICE AND CATA CABLES, CATEGORY 5E PLENUM, LONGEST RUN 160 FEET AS PER 2005 NEC ARTICLES 300.21 & 800.

  742. PermitFast form building

    Permit 138311 · COMPLETED

  743. PermitElectrical

    Permit 130303 · COMPLETED

    DEMO OF EXISTING TRAINING ROOM, BOARD ROOM. ADD 15 NEW 2X2 FIXTURES & 40 NEW DOWN LIGHTS, 11 DUPLEX RECEPTS, 4 SINGLE POLE SWITCHES, 1 EXIT SIGN. RE USE ALL EXISTING CIRCUITRY FROM DEMO AS PER 2005 NEC (CC DISTRICT)

  744. PermitMechanical

    Permit 132837 · COMPLETED

    RELOCATE 10 DIFFUSERS/REGISTERS (36TH & 40TH FLOOR - ERNST YOUNG OFFICE)

  745. PermitMajor alteration

    Permit 124580 · COMPLETED

    INTERIOR RENOVATIONS

  746. PermitElectrical

    Permit 118021 · COMPLETED

    DEMOLITION OF OLD LIGHTING AND POWER, ADD 19 PENDANT LIGHTS, K20 DOWN LIGHTS, 20 DUPLEX RECEPTS, 14 DOUBLE DUPLEX RECEPTS. RE USE ALL EXISTING CIRCUITRY FROM DEMO AS PER 2005 NEC (CC DISTRICT)

  747. PermitFast form building

    Permit 120974 · COMPLETED

  748. PermitElectrical

    Permit 119868 · COMPLETED

    (6) DUPL RECEPTS, (2) RELOCATE EXISTING LTS, (15) RELAMP EXISTING LTG, (2) INSTALL WALL SCONCE FXTS, (7) CAT 5E VOICE/DATA JACKS, (1) CAT 5E, 12 PORT PATCH PANEL.(CC DIST)

  749. PermitMechanical

    Permit 119452 · COMPLETED

    RELOCATE (2) REGISTERS/DIFFUSERS

  750. PermitFast form building

    Permit 119575 · COMPLETED

  751. PermitPlumbing

    Permit 118759 · COMPLETED

    INSTALLATION OF NEW PANTRY SINK

  752. PermitElectrical

    Permit 119222 · COMPLETED

    62 CATEGORY 5E CABLE FOR VOICE AND DATA (CC DIST)

  753. PermitMechanical

    Permit 119058 · COMPLETED

    RELOCATE 21 DIFFUSSERS

  754. PermitMajor alteration

    Permit 117757 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLAN

  755. PermitFast form building

    Permit 117995 · COMPLETED

  756. PermitMajor alteration

    Permit 116320 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLANS

  757. PermitElectrical

    Permit 72948 · COMPLETED

    INSTALL 3 SPEAKERS, AND 2 SPEAKER STROBES (CC DISTRICT)

  758. PermitElectrical

    Permit 67599 · COMPLETED

    ADD (1) 208 100AMP PANEL (10) DUPL RECEPTS, (1) QUAD, (3) FURNITURE FEEDS, (2) SWS, (7) SENSORS, (24) LT FXTS. (CC DIST)

  759. PermitElectrical

    Permit 75048 · COMPLETED

    REMOVE & RELOCATE 16 LIGHT FIXTURES, 12 DUPLEX RECEPTACLES & 3 FURNITURE FEEDS.

  760. InvestigationCI HAZMAT

    Case 111217 · PASSED

    The cited inspection visit was marked passed.

  761. ViolationINT MATERIAL STORAGE

    Case 111217 · Violation 560739 · Code FC-315.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  762. ViolationWORKMANLIKE- FIRE CODE

    Case 111217 · Violation 560738 · Code A-104.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  763. PermitElectrical

    Permit 72949 · COMPLETED

    INSTALL 60 VOICE AND DATA LINES, CAT 5E, PVC LONGEST RUN 60'(CC DISTRICT)

  764. ViolationCOO- MAINT/DAMAGE/FIRE/CONSTR

    Case 111217 · Violation 560737 · Code A-505.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  765. ViolationVIOL C&I MESSAGE

    Case 111217 · Violation 560736 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  766. InvestigationCI HAZMAT

    Case 111217 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  767. PermitMechanical

    Permit 70725 · COMPLETED

    RELOCATE 8 REGISTERS/DIFFUSERS

  768. PermitFast form building

    Permit 67890 · COMPLETED

  769. PermitMajor alteration

    Permit 66188 · COMPLETED

    CONSTRUCTION OF INTERIOR NON-LOAD BEARING PARTITIONS,AND DOORS

  770. PermitPlumbing

    Permit 55696 · COMPLETED

    INSTALL A NEW KITCHEN SINK ON AN EXISTING STACK

  771. PermitElectrical

    Permit 55264 · COMPLETED

    RENOVATION TO EXISTING COPY ROOM (37D3) AND CUSTOMER SERVICE OFFICE (375E), INSTALL 10 DUPLEX RECETPS USING EXISTING CIRCUITS, NO FIRE ALARM WORK

  772. PermitElectrical

    Permit 55010 · COMPLETED

    INSTALL (9) DUPLEX RECEPTACLES AND RELOCATE (1) WALL SWITCH

  773. PermitMajor alteration

    Permit 50820 · COMPLETED

    INTERIOR RENOVATIONS PER PLANS

  774. PermitElectrical

    Permit 50719 · COMPLETED

    REPL(5)F.A STROBE LTS,(1)F.A.TEST & RECERT,(8)DUP RECEPTS,(11) RELOCATE EXISTING FURNITURE FEEDS,(6)SWS,(16)RELOCATE EXISTING LTG,(4)ADD NEW EXIT LTS,(13)REC.LTG TO RELOCATE,(12)VOICE/DATA "BOX & STRING",(1)UPDATE PANEL BOARD DIRECTORIES AS REQUIRED.REUSE EXISTING CIRCUITS MADE AVAILABLE FROM DEMO OF EXISTING.

  775. PermitMajor alteration

    Permit 50167 · COMPLETED

    REMOVING EXISTING VINYL FLOORING AND VINYL BASE. CONSTRUCT DRYWALL NON-LOAD BARING PARTITIONS. MODIFY EXISTING SUITE ENTRANCE AS PER PLAN.

  776. PermitFast form building

    Permit 50483 · COMPLETED

  777. PermitFast form building

    Permit 50691 · COMPLETED

  778. PermitMajor alteration

    Permit 48233 · COMPLETED

    TENANT FIT-OUT. CONSTRUCTION OF INTERIOR, NON-LOAD BEARING PARTITIONS, DOORS, FRAMES AND HARDWARE, FINISHES, SPRINKLER, HVAC AND ELECTRICAL WORK,TO SUIT NEW LAYOUT. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS.

  779. License terminal eventBEERSHEBA ENTERPRISE LLC (BIRDS BIRDS BIRDS): Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 209855 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  780. InvestigationBC INSP (likely: building-code inspection)

    Case 53094 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  781. License issue eventJOHN ROCCO JR: Food Estab, Retail Non-Permanent Location (Annual) L&I license filing initially issued

    License 321570 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  782. License issue eventPHILADELPHIA PLAZA-PHASE II: Hazardous Materials L&I license filing initially issued

    License 285717 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  783. License issue eventTWO COMMERCE SQ MARATHON GRILL: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 209071 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  784. License issue eventPHILADELPHIA PLAZA PHASE II: High Rise L&I license filing initially issued

    License 299017 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  785. License issue eventBEERSHEBA ENTERPRISE LLC (BIRDS BIRDS BIRDS): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 209855 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  786. License issue eventCLEMENT CIZEWSKI (MODERN_RESTAURANTS): Dumpster License - Private Property L&I license filing initially issued

    License 278716 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 25, 2026, 4:58 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)