House report

206 W Clapier St

3 bd1 ba2 stories1,314 sqftRSA5built 1900

Property at a glanceHouse

Owner-occupancy signal

2026 assessment
$167K OPA value, not a listing price
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

Published City assessments for this house against its block and ZIP. Dated City filings are marked on the same line. Select one to read it. Assessments are tax-roll values, not sale prices or appraisals.

$0$125K$250KZIP 19144 (Germantown) median$167K201420172020202320262027
Property assessmentBlock median & rangeZIP 19144 (Germantown) medianAssessmentL&I violationPermitInspection

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record28 events · exact dates, newest first
  1. InspectionL&I investigation
  2. InspectionL&I investigation
  3. L&I violationEXTERIOR STRUCTURE DECORATIVE FEATURES
  4. L&I violationCONCRETE COMPONENTS
  5. L&I violationPLUMBING SYSTEMS- GENERAL
  6. L&I violationPLUMBING SYSTEMS- HAZARDS
  7. L&I violationPLUMBING SYSTEMS- SANITARY DRAINAGE
  8. InspectionL&I investigation
  9. InspectionL&I investigation
  10. L&I violationINSPECT-CONTR MUST ARRANGE
  11. L&I violationNOT CONFORM TO PRC/NEC
  12. L&I violationGROUND-SYSTEM PROPERLY
  13. L&I violationRACEWAY-SECURE & SUPPORT
  14. L&I violationBOX-MUST SECURELY FASTEN
  15. InspectionEP_ELEC
  16. L&I violationCOMPL CONCEAL- PLUMB PERM WORK
  17. InspectionBP_BLDG
  18. PermitMechanical
  19. PermitPlumbing
  20. PermitElectrical
  21. L&I violationPERMP- INST NEW PLUMBING
  22. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  23. L&I violationPERMB- INSTALL HVAC SYS
  24. L&I violationPERMB- INSTALL DUCTWORK
  25. L&I violationPERMB REVK- FLSE APPL STATEM'T
  26. L&I violationEGRESS TRASH/GARBAGE FREE
  27. InspectionBP_BLDG
  28. PermitMajor alteration

Flags: historical tax ledger through 2016 recorded $9K with a lien entry · latest deed has shared-name parties; relationship unverified. Informational only. Not investment advice or a consumer report (FCRA).

Verify the public record

$932/year estimated property tax

2026 taxable assessment $66,600 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $166,700. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 133052500
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationHomestead exemption

2026 OPA removes $100,000 from the taxable assessment through the owner-occupant exemption.

Historical delinquency sources Record found

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

A separate historical parcel ledger ending in 2016 records $8,730.34 and a lien entry. It is shown as historical context only.

2012$2,356.60 total · $971.88 principal · $364.46 interest · $68.03 penalty2013$1,633.38 total · $1,006.80 principal · $286.94 interest · $70.48 penalty2014$1,871.20 total · $1,185.03 principal · $231.08 interest · $82.95 penalty2015$1,745.35 total · $1,185.03 principal · $124.43 interest · $82.95 penalty2016$1,123.81 total · $949.76 principal · $14.24 interest · $9.50 penalty

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Where the record looks off

Conflicts in City paperwork. Flags on the data, not the property.

"Built 1900" is usually a placeholder

Philadelphia records use 1900 as a stand-in when the real construction year was never documented. Treat the age as unknown, not as 120+ years.

The property, on paper

OPA physical field record.

Bedrooms
3
Bathrooms
1
Stories
2
Interior
1,314 sqft livable area
Lot
1,363 sqft
Exterior condition
Average city code 4
Interior condition
Average city code 4
Quality grade
C assessor's grade
Zoning
RSA5 city zoning code

OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.

Block context

200 block of W Clapier St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 204 W Clapier St  ·  208 W Clapier St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 28 dated rows
  1. InvestigationL&I investigation

    Case CF-2025-034731 · PASSED

    The cited inspection visit was marked passed.

  2. InvestigationL&I investigation

    Case CF-2025-034731 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  3. ViolationEXTERIOR STRUCTURE DECORATIVE FEATURES

    Case CF-2025-034731 · Violation VI-2025-027379 · Code PM15-304.8 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  4. ViolationCONCRETE COMPONENTS

    Case CF-2025-034731 · Violation VI-2025-027380 · Code PM15-306.1(2) · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  5. ViolationPLUMBING SYSTEMS- GENERAL

    Case CF-2025-034731 · Violation VI-2025-027381 · Code PM15-504.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  6. ViolationPLUMBING SYSTEMS- HAZARDS

    Case CF-2025-034731 · Violation VI-2025-027382 · Code PM15-504.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  7. ViolationPLUMBING SYSTEMS- SANITARY DRAINAGE

    Case CF-2025-034731 · Violation VI-2025-027383 · Code PM15-506.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  8. InvestigationL&I investigation

    Case CF-2025-034731 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  9. InvestigationL&I investigation

    Case CF-2025-034731 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  10. ViolationINSPECT-CONTR MUST ARRANGE

    Case 499722 · Violation 3692962 · Code E-701.1/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  11. ViolationNOT CONFORM TO PRC/NEC

    Case 499722 · Violation 3692958 · Code E-1201.1/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  12. ViolationGROUND-SYSTEM PROPERLY

    Case 499722 · Violation 3692959 · Code E-1201.1/229 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  13. ViolationRACEWAY-SECURE & SUPPORT

    Case 499722 · Violation 3692960 · Code E-1201.1/301 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  14. ViolationBOX-MUST SECURELY FASTEN

    Case 499722 · Violation 3692961 · Code E-1201.1/318 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  15. InvestigationEP_ELEC

    Case 499722 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. ViolationCOMPL CONCEAL- PLUMB PERM WORK

    Case 559440 · Violation 3516671 · Code A-402.1/4 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  17. InvestigationBP_BLDG

    Case 448216 · PASSED

    The cited inspection visit was marked passed.

  18. PermitMechanical

    Permit 559440 · EXPIRED

    INSTALL 1 HVAC UNIT WITH DUCTWORK(SFD)SEE HANSEN CASE 448216

  19. PermitPlumbing

    Permit 558641 · COMPLETED

    INTERIOR PLUMBING ALTERATIONS THROUGHOUT AN EXISTING SINGLE-FAMILY DWELLING - (1)LAVATORY, (1)WATER CLOSET, (1)BATHTUB AND (1)KITCHEN SINK

  20. PermitElectrical

    Permit 558228 · COMPLETED

    PARTIAL REWIRE AS PER NEC 2008 (SFD)

  21. ViolationPERMP- INST NEW PLUMBING

    Case 448216 · Violation 3294302 · Code A-301.1/54 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 448216 · Violation 3294301 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  23. ViolationPERMB- INSTALL HVAC SYS

    Case 448216 · Violation 3294300 · Code A-301.1/46 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  24. ViolationPERMB- INSTALL DUCTWORK

    Case 448216 · Violation 3294299 · Code A-301.1/43 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  25. ViolationPERMB REVK- FLSE APPL STATEM'T

    Case 531017 · Violation 3335069 · Code A-302.9/39 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  26. ViolationEGRESS TRASH/GARBAGE FREE

    Case 531017 · Violation 3335070 · Code PM-603.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  27. InvestigationBP_BLDG

    Case 448216 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  28. PermitMajor alteration

    Permit 531017 · EXPIRED

    INTERIOR ALTERATIONS TO INCLUDE NEW DRY WALL. APPLICANT AGREES TO LIMIT THE CONSTRUCTION TO COMPLY WITH EZ PERMIT STANDARD FOR INTERIOR ALTERATIONS, DATED JANUARY 2011. DEVIATION FROM THE STANDARD WILL RESULT IN REVOCATION OF THIS PERMIT AND IMPOSITION OF FURTHER PENALTIES.

Where this comes from

Methodology & freshness

This report was assembled Jul 23, 2026, 8:14 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)