Commercial property report

2200 Oregon Ave

Research this property with Analyst →

1 story184,505 sqftCA2built 2004

Property at a glanceStore

Quartermaster Plaza 1777 LLC

2026 assessment
$26M OPA value, not a listing price
2027 published assessment
$31M Future roll, not the current tax bill
Neighborhood area
Girard Estate · South Philadelphia Approximate · based on ZIP 19145
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $31,365,800. It is not yet the billed-year tax basis.

$0$25M$50M$31M2005200920132017202120252027
Property assessmentAssessmentL&I violationAppealPermitInspection

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record107 events · exact dates, newest first
  1. PermitAddition and/or Alteration
  2. PermitSign
  3. PermitAlterations
  4. PermitAddition and/or Alteration
  5. PermitAddition and/or Alterations
  6. PermitAddition and/or Alteration
  7. PermitAddition and/or Alterations
  8. PermitAddition and/or Alteration
  9. InspectionL&I investigation
  10. PermitAddition and/or Alterations
  11. PermitAddition and/or Alteration
  12. PermitAddition and/or Alteration
  13. PermitSign
  14. PermitSign
  15. PermitSign
  16. PermitAddition and/or Alterations
  17. PermitAddition and/or Alteration
  18. InspectionL&I investigation
  19. InspectionL&I investigation
  20. InspectionL&I investigation
  21. InspectionL&I investigation
  22. InspectionL&I investigation
  23. L&I violationPERIODIC TESTING
  24. L&I violationINSPECTION, TESTING AND MAINTENANCE
  25. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  26. L&I violationFDC EXISTING BUILDING SIGN
  27. L&I violationFIRE EXTINGUISHERS REQUIRED
  28. L&I violationRENEW FOOD ESTABLISHMENT, RETAIL PERM LOCATION (LARGE) 3119
  29. InspectionL&I investigation
  30. PermitAddition and/or Alteration
  31. PermitAddition and/or Alteration
  32. PermitAddition and/or Alteration
  33. InspectionL&I investigation
  34. PermitNew Construction
  35. PermitAddition and/or Alterations
  36. PermitRough-In
  37. PermitAddition and/or Alteration
  38. PermitAddition and/or Alteration
  39. PermitAddition and/or Alterations
  40. PermitAlterations
  41. PermitAddition and/or Alteration
  42. L&I violationFIRE ALARM TESTED/CERTIFIED
  43. L&I violationNEW USE
  44. L&I violationSAFETY DATA SHEETS/CONTAINER
  45. L&I violationNFPA 704 SIGNS
  46. L&I violationHAZMAT LICENSE REQUIRED
  47. L&I violationEMERGENCY LIGHTING TESTED
  48. InspectionL&I investigation
  49. InspectionL&I investigation
  50. L&I violationNFPA 704 SIGNS
  51. L&I violationFIRE ALARM TESTED/CERTIFIED
  52. L&I violationHAZMAT LICENSE REQUIRED
  53. L&I violationEMERGENCY LIGHTING TESTED
  54. L&I violationSAFETY DATA SHEETS/CONTAINER
  55. InspectionL&I investigation
  56. PermitNew Construction
  57. PermitSitework with Onsite Utility Services
  58. InspectionL&I investigation
  59. L&I violationLIQUID PETROLEUM GASES
  60. L&I violationFDC LOCKING CAPS
  61. PermitTemporary Tents and Canopies
  62. PermitTemporary Tents and Canopies
  63. PermitPlumbing
  64. PermitAlterations
  65. PermitElectrical
  66. PermitZoning/use
  67. PermitSign
  68. PermitPlumbing
  69. PermitMajor alteration
  70. PermitMechanical
  71. PermitElectrical
  72. PermitSign
  73. PermitZoning/use
  74. PermitUse
  75. PermitOperations
  76. PermitMechanical
  77. PermitZoning/use
  78. PermitMechanical
  79. PermitSign
  80. PermitMajor alteration
  81. PermitUse
  82. PermitZoning/use
  83. PermitMechanical
  84. PermitMajor alteration
  85. PermitZoning/use
  86. PermitZoning/use
  87. PermitPlumbing
  88. PermitZoning/use
  89. AppealZoning board appeal
  90. PermitSign
  91. PermitSuppression
  92. PermitPlumbing
  93. InspectionCI INSP
  94. InspectionCI INSP
  95. PermitPlumbing
  96. InspectionBC INSP (likely: building-code inspection)
  97. InspectionBC INSP (likely: building-code inspection)
  98. InspectionBC INSP (likely: building-code inspection)
  99. InspectionBC INSP (likely: building-code inspection)
  100. InspectionBC INSP (likely: building-code inspection)
  101. InspectionCI INSP
  102. InspectionCI INSP
  103. InspectionCI INSP
  104. InspectionCI INSP
  105. InspectionBC INSP (likely: building-code inspection)
  106. InspectionL_CLIP
  107. InspectionL_CLIP

Verify the public record

$358,996/year estimated property tax

2026 taxable assessment $25,646,200 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $31,365,800. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 882245000
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Store, recorded in the City's commercial category. The public record and owner trail follow.

What it is
Store Shop Cent Area Masonry
Owner
Quartermaster Plaza 1777 LLC
$ / sq ft
$170 above the $151 median for 7,668 commercial parcels citywide
Corridor
Quartermaster Plaza and vicinity city commercial corridor
Interior area
184,505 sqft
Lot size
1,102,643 sqft
Stories
1
Built
2004
Zoning
CA2

Recorded owner

Who's behind it

Quartermaster Plaza 1777 LLC · corporate / LLC owner

• Owns 3 properties across Philadelphia under this name, assessed at $60M combined
• Tax bills mail to C/O Dra Advisors Llc 575 Fifth Avenue 38th Floor, New York NY, 10017 — outside Philadelphia

Block context

2200 block of Oregon Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 2200r Oregon Ave  ·  2200 Oregon Ave

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 107 dated rows
  1. PermitAddition and/or Alteration

    Permit CP-2026-002984 · Issued

    FOR A LEVEL II INTERIOR ALTERATIONS TO INCLUDE AN OCCUPANCY CHANGE TO AN EXISTING TENANT SPACE. FOR USE AS A BUSIESS OCCUPANCY ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  2. PermitSign

    Permit GP-2025-011308 · Completed

    FOR THE INSTALLATION OF TWO (2) STATICALLY ILLUMINATED WALL SIGNS.

  3. PermitAlterations

    Permit PP-2025-001057 · Completed

    INSTALL 1 MOP SINK, 2 KITCHEN SINKS, 3 LAVATORIES, 1 HOT WATER HEATER, 2 WATER CLOSETS AND 1 ELECTRIC WATER COOLER ACCORDING TO THE 2018 PPC AND PER PLANS.

  4. PermitAddition and/or Alteration

    Permit EP-2025-003300 · Completed

    install 16 new kcat6 line for computers

  5. PermitAddition and/or Alterations

    Permit FP-2025-000743 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (16) SPRINKLER HEADS AS PER NFPA 13 AND LOCAL CODE

  6. PermitAddition and/or Alteration

    Permit EP-2025-003096 · Completed

    AMEND Telecommunications wiring Installation of lighting, outlets and switches

  7. PermitAddition and/or Alterations

    Permit MP-2025-000412 · Completed

    FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, EXHAUSTS, AND ASSOCIATED DUCTWORK AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2025-000129 FOR ASSOCIATED BUILDING PERMIT.

  8. PermitAddition and/or Alteration

    Permit CP-2025-000129 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  9. InvestigationL&I investigation

    Case CF-2023-044417 · PASSED

    The cited inspection visit was marked passed.

  10. PermitAddition and/or Alterations

    Permit MP-2024-002522 · Completed

    FOR THE INSTALLATION OF HVAC APPLIANCES AND EQUIPMENT PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS.

  11. PermitAddition and/or Alteration

    Permit EP-2024-004651 · Completed

    Commercial, Sprouts Farmers Market #855 Disconnect existing electrical for refacing of existing free-standing signs and increasing of the size of the signs per plans, and then reconnect electrical after erection of five (5) flat wall signs to existing 120-V electrical junction box. We are not running any new wire, disconnecting from existing and reconnecting to existing wiring after signs are refaced and increased in size per sign permit ZP-2023-008558 and GP-2024-001650.

  12. PermitAddition and/or Alteration

    Permit EP-2024-004423 · Completed

    INSTALLATION OF TELECOMMUNICATION WIRING IN BUILDING ACCORDING TO THE 2017 NEC.

  13. PermitSign

    Permit GP-2024-001970 · Expired

    FOR THE INSTALLATION OF ONE FLAT WALL SIGN AS PER PLANS.

  14. PermitSign

    Permit GP-2024-001650 · Completed

    FOR THE REFACING OF EXISTING FREE-STANDING SIGNS. FOR THE ERECTION OF FIVE (5) FLAT WALL SIGN AS PER APPROVED PLANS.

  15. PermitSign

    Permit GP-2024-001599 · Completed

    FOR THE ERECTION OF ONE (1) FLAT ILLUMINATED WALL SIGN. AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ELECTRICAL WORK.

  16. PermitAddition and/or Alterations

    Permit FP-2024-000343 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13) - For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating 54 existing sprinkler heads for renovations

  17. PermitAddition and/or Alteration

    Permit EP-2023-011041 · Completed

    Installation of a new 150 AMP/ 3phase service from existing panel: in 2" EMT pipe as per 2017 NEC. 14 20 AMP GFCI receptacles, 2 30 AMP receptacles for HVAC and hot water heater, 4 40 AMP receptacle for deep fryer, 2 hard wired exit signs 2 hard wired emergency flood lights, 7 light switches, 3 exterior light 1 exterior receptacle for sign, 2 horn and strobes, and 1 shunt breaker box for fire suppression system. AS PER NEC 2017

  18. InvestigationL&I investigation

    Case CF-2021-110462 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  19. InvestigationL&I investigation

    Case CF-2021-110462 · PASSED

    The cited inspection visit was marked passed.

  20. InvestigationL&I investigation

    Case CF-2023-044417 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  21. InvestigationL&I investigation

    Case CF-2023-044417 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  22. InvestigationL&I investigation

    Case CF-2023-044417 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  23. ViolationPERIODIC TESTING

    Case CF-2023-044417 · Violation VI-2023-034039 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  24. ViolationINSPECTION, TESTING AND MAINTENANCE

    Case CF-2023-044417 · Violation VI-2023-034038 · Code F-907.8.5 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  25. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2023-044417 · Violation VI-2023-034040 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  26. ViolationFDC EXISTING BUILDING SIGN

    Case CF-2023-044417 · Violation VI-2023-034041 · Code F-912.2.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  27. ViolationFIRE EXTINGUISHERS REQUIRED

    Case CF-2023-044417 · Violation VI-2023-034042 · Code F-906.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. ViolationRENEW FOOD ESTABLISHMENT, RETAIL PERM LOCATION (LARGE) 3119

    Case CF-2023-044417 · Violation VI-2023-034073 · Code L - O · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. InvestigationL&I investigation

    Case CF-2021-110462 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  30. PermitAddition and/or Alteration

    Permit EP-2022-003551 · Expired

    Intrusion Alarm turn key system as per 2017 nec

  31. PermitAddition and/or Alteration

    Permit EP-2022-011252 · Completed

    Electrical Permit for combo CP-2022-004649

  32. PermitAddition and/or Alteration

    Permit CP-2022-004649 · Completed

    FOR ALTERATIONS TO AN EXISTING STRUCTURE TO INCLUDE NEW ELECTRIC ENTRANCE GATES **SEPARATE PERMITS TO BE REQUIRED FOR ANY ELECTRICAL AND FIRE SUPPRESSION SYSTEM INSTALLATIONS. **

  33. InvestigationL&I investigation

    Case CF-2020-081871 · PASSED

    The cited inspection visit was marked passed.

  34. PermitNew Construction

    Permit MP-2022-000665 · Completed

    INSTALLATION OF NEW HVAC SYSTEM FOR RETAIL SHOE STORE IN SPACE 011 OF AN EXISTING SHOPPING CENTER AS PER APPROVED PLANS. *2018 IMC REVIEW*

  35. PermitAddition and/or Alterations

    Permit FP-2022-000130 · Completed

    For the installation of an automatic wet sprinkler system in accordance with NFPA 13 (using an existing, four (4) inch fire service line, and a new four (4) inch backflow prevention device located at the back of house area), throughout tenant space #11 within an existing single-story detached structure to be used as Group M ("Foot Locker"), as per plans and hydraulic calculations; see CP-2021-007891 for building permit; tenant spans spaces #11 and #12, sprinkler system within tenant space #12 to remain with no work proposed.

  36. PermitRough-In

    Permit FP-2022-000151 · Expired

    Rough-In Permit for FP-2022-000130 in Suite 11 & 12 (CP-2021-007891)

  37. PermitAddition and/or Alteration

    Permit EP-2021-014661 · Expired

    INSTALL A NEW ADDRESSABLE FIRE ALARM SYSTEM THROUGHOUT. REWIRE THE EXISTING DEVICES DESIGNATE TO REMAIN, WIRE ALL THE NEW EQUIPMENT AND DEVICES. ALL WORK IN ACCORDANCE WITH THE 2017 NEC & 2016 NFPA-72.

  38. PermitAddition and/or Alteration

    Permit EP-2021-014503 · Completed

    Electrical Permit for combo CP-2021-007891

  39. PermitAddition and/or Alterations

    Permit FP-2021-003478 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (125) Sprinkler heads at Quartermaster Plaza, Footlocker SPACES 11 AND 12 (CP-2021-007891)

  40. PermitAlterations

    Permit PP-2021-023119 · Completed

    Plumbing Permit (Interior) for combo CP-2021-007891

  41. PermitAddition and/or Alteration

    Permit CP-2021-007891 · Completed

    INTERIOR ALTERATION TO INCLUDE TENANT FIT-OUT TO COMBINE SPACES 11 AND 12 AS SHOWN ON PLANS FOR RETAIL SALES OF WEARING APPAREL AND ACCESSORIES (FOOTLOCKER) WITHIN AN EXISTING ONE (1) STORY SPACE AS PER APPROVED PLANS.

  42. ViolationFIRE ALARM TESTED/CERTIFIED

    Case CF-2021-110462 · Violation VI-2021-079492 · Code FC-13-915.1 · CLOSED

    Resolution: CLOSED - REISSUED/REWRITTEN City marked the record closed; open the case for the closing reason.

  43. ViolationNEW USE

    Case CF-2021-110462 · Violation VI-2021-079497 · Code A-301.1/65 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  44. ViolationSAFETY DATA SHEETS/CONTAINER

    Case CF-2021-110462 · Violation VI-2021-079496 · Code FC-13-2701.8 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  45. ViolationNFPA 704 SIGNS

    Case CF-2021-110462 · Violation VI-2021-079495 · Code FC-13-2703.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  46. ViolationHAZMAT LICENSE REQUIRED

    Case CF-2021-110462 · Violation VI-2021-079494 · Code FC-13-2701.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  47. ViolationEMERGENCY LIGHTING TESTED

    Case CF-2021-110462 · Violation VI-2021-079493 · Code FC-13-604.1 · CLOSED

    Resolution: CLOSED - REISSUED/REWRITTEN City marked the record closed; open the case for the closing reason.

  48. InvestigationL&I investigation

    Case CF-2021-110462 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  49. InvestigationL&I investigation

    Case CF-2021-106355 · PASSED

    The cited inspection visit was marked passed.

  50. ViolationNFPA 704 SIGNS

    Case CF-2021-106355 · Violation VI-2021-076643 · Code FC-13-2703.5 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  51. ViolationFIRE ALARM TESTED/CERTIFIED

    Case CF-2021-106355 · Violation VI-2021-076640 · Code FC-13-915.1 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  52. ViolationHAZMAT LICENSE REQUIRED

    Case CF-2021-106355 · Violation VI-2021-076642 · Code FC-13-2701.5 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  53. ViolationEMERGENCY LIGHTING TESTED

    Case CF-2021-106355 · Violation VI-2021-076641 · Code FC-13-604.1 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  54. ViolationSAFETY DATA SHEETS/CONTAINER

    Case CF-2021-106355 · Violation VI-2021-076644 · Code FC-13-2701.8 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  55. InvestigationL&I investigation

    Case CF-2021-106355 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  56. PermitNew Construction

    Permit EP-2021-002816 · Completed

    FOR THE INSTALLATION OF SIX (6) EV CHARGING STATIONS AND ELECTRICAL EQUIPMENT, AS PER APPROVED PLANS.

  57. PermitSitework with Onsite Utility Services

    Permit SP-2021-000077 · Completed

    FOR THE INSTALLATION OF SIX (6) EV CHARGING STATIONS AND ELECTRICAL EQUIPMENT, AS PER APPROVED PLANS.

  58. InvestigationL&I investigation

    Case CF-2020-081871 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  59. ViolationLIQUID PETROLEUM GASES

    Case CF-2020-081871 · Violation VI-2020-048925 · Code FC-13-3809.12 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  60. ViolationFDC LOCKING CAPS

    Case CF-2020-081871 · Violation VI-2020-048926 · Code FC-13-912.3.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  61. PermitTemporary Tents and Canopies

    Permit OP-2020-000230 · Expired

    Erect a 30' x 30' tent for use with Tables and Chairs.

  62. PermitTemporary Tents and Canopies

    Permit OP-2020-000115 · Expired

    20'X40' frame tent installed for fireworks sales

  63. PermitPlumbing

    Permit 901768 · EXPIRED

    NEW WATER SERVCIE FROM PRIVATE MAIN PA20181911074(RETAIL)"SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  64. PermitAlterations

    Permit 894183 · Completed

    SUPPLY AND INSTALL WATTS MODEL LF009M2QT 1 1/2" BACKFLOW PREVENTOR.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  65. PermitElectrical

    Permit 849688 · COMPLETED

    FURNISH AND INSTALL LIGHTS, SWITCHES, RECEPTSAND PANELS, 30KVA TRANSFORMER AS PER 2008 NEC (SOUTH DISTRICT)

  66. PermitZoning/use

    Permit 856185 · COMPLETED

    FOR THE ERECTION OF TWO (2)INTERNALLY ILLUMINATED ACCESSORY FLAT WALL SIGN ACCESSORY TO A PREVIOUSLY APPROVED GROUP PRACTITIONER OFFICE ON SPACE (20-A) OF AN EXISTING STRUCTURE WITH OTHER USES AND OFF-STREET PARKING AS PREVIOUSLY APPROVED AS PART OF A SHOPPING COMPLEX.(SIZE AND LOCATION AS SHOWN ON THE PLAN).

  67. PermitSign

    Permit 856186 · COMPLETED

    FOR THE ERECTION OF TWO (2)INTERNALLY ILLUMINATED ACCESSORY FLAT WALL SIGN ACCESSORY TO A PREVIOUSLY APPROVED GROUP PRACTITIONER OFFICE IN SPACE (20-A) OF AN EXISTING STRUCTURE DETAILS AS SHOWN ON THE PLAN).

  68. PermitPlumbing

    Permit 843939 · COMPLETED

    2WATER CLOSETS, 2LAV SINKS, 1WATER COOLER, 1MOP SINK, 1 WASH MACH STAND PIPE, 2HAND SINKS, 1FLOOR DRAIN.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUMBING CODE 2004

  69. PermitMajor alteration

    Permit 836359 · COMPLETED

    LEVEL II ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE A REHABILITATION CENTER (GROUP MEDICAL OFFICE) IN SPACE 20A OF AN EXISTING SHOPPING CENTER AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  70. PermitMechanical

    Permit 838269 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR A NEW REHAB CENTER (GROUP MEDICAL OFFICE) IN SPACE 20A OF AN EXISTING SHOPPING CENTER AS PER APPROVED PLANS.

  71. PermitElectrical

    Permit 825646 · COMPLETED

    INSTALL NEW 200 AMP SERVICE TO VACANT SPACE, TERMINATE TO THE LINE SIDE OF A FUSED DISCONNECT SWITCH WITH THE SPACE, PROVIDE CONDUIT ONLY FOR DATA PER 2008 NEC (COMMERICAL)

  72. PermitSign

    Permit 828277 · COMPLETED

    FOR THE REMOVAL OF ONE (1) EXISTING FLAT WALL SIGN AND THE INSTALLATION OF ONE (1) STATICALLY ILLUMINATED FLAT WALL (CABINET) SIGN ACCESSORY FOR AN EXISTING RETAIL SALE OF BUILDING SUPPLIES AND EQUIPMENT IN AN EXISTING SHOPPING CENTER IN SPACE 160 AS PER ENGINEER'S PLAN, ** SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL WORK **

  73. PermitZoning/use

    Permit 823420 · COMPLETED

    INSTALL (1) EXISTING ILLUMINATED SIGN CABINET. 36"X120"=30SF

  74. PermitUse

    Permit 811780 · COMPLETED

    CREATE 2 SPACES (20A/20B) FROM 1 SPACE (20). WORK IN SPACE 20 A ONLY. SPACE 20A- MEDICAL OFFICE (NOVA CARE) WITH CHIROPRACTIC SERVICES (NO OVER NIGHT STAYS). 35'0"X81'4" (2810SQFT). SPACE 20B - TO REMAIN VACANT AT THIS TIME. 22'3" X 86'7" (2200 SQFT) S/0 REQUESTED IF NECESSARY.

  75. PermitOperations

    Permit 23537 · COMPLETED

    06/10/2015 ERECT TENT (80'X130') HOME DEPOT

  76. PermitMechanical

    Permit 597936 · COMPLETED

    HVAC TO INCLUDE DUCTWORK AS PER PLAN, 8 REGISTERS/DIFFUSERS

  77. PermitZoning/use

    Permit 514052 · COMPLETED

    FOR USE AS PERMITTED IN AREA SHOPPING CENTER (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY FOR BOTH BUILDINGS M&S) ON THE SAME LOT EXISTING NINETEEN(19) BUILDINGS INCLUDING WITH OUTDOOR RETAIL SPACE; FOR THE REDUCTION OF TOTAL ACCESSORY PARKING SPACES TO 2,384 INCLUDING WITH SIXTY-FOUR(64) ACCESSIBLE SPACES; TEN(10)BICYCLE SPACES ( SHOULD BE IN ACCESSIBLE ROUTE) AND TWO(2) LOADING SPACES ACCESSORY TO BUILDING M WITH ALL OTHER USES INCLUDING WITH ACCESSORY SIGNS AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION.

  78. PermitMechanical

    Permit 472194 · EXPIRED

    REMOVE TWO (2) EXISTING ROOFTOP UNITS AND REPLACE IN KIND WITH NEW FIVE (5) TON HVAC UNITS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL WORK.

  79. PermitSign

    Permit 466645 · COMPLETED

    INSTALL RACEWAY MOUNT INTERNALLY ILLUMINATED CHANNEL LETTERS

  80. PermitMajor alteration

    Permit 458132 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE TO INCLUDE ALTERATIONS TO EXISTING LAYOUT AND PROVIDE ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. TENANT SPACE TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.

  81. PermitUse

    Permit 466223 · COMPLETED

    CHANGE OF USE FROM VACANT CORNERSTONE TO EDIBLE ARRANGEMENTS

  82. PermitZoning/use

    Permit 463271 · COMPLETED

    INSTALL RACEWAY MOUNT INTERNALLY ILUUMINATED CHANNELL LETTERS

  83. PermitMechanical

    Permit 425346 · EXPIRED

    RELOCATE DIFFUSERS AND DUCTWORK WITHIN EXISTING VERIZON STORE. SEE ALTERATION PERMIT #421871 FOR PLANS.

  84. PermitMajor alteration

    Permit 421871 · EXPIRED

    INTERIOR RENOVATIONS OF EXISTING VERIZON STORE AS PER PLANS. HVAC PERMIT UNDER AP#425346.

  85. PermitZoning/use

    Permit 420925 · COMPLETED

    FOR THE REMOVAL OF ALL EXISTING SIGNS AND FOR THE ERECTION OF THREE INTERNALLY ILLUMINATED FLAT WALL SIGNS: (62"(H) X 337.75"(W)-EAST SIDE OF BUILDING), (18"(H) X 168.75"(W)-SOUTH SIDE OF BUILDING), (24"(H) X 225"(W)-WEST SIDE OF BUILDING) AND FOR THE REFACING OF A DOUBLE FACED ACCESSORY PANEL (24"(H) X 71.25"(W)) ON AN EXISTING FREE STANDING PYLON SIGN. SIGNS ARE ACCESSORY TO A RETAIIL SALE OF MATTRESSES AND BEDDING SUPPLIES WITHIN AN EXISTING SHOPPING CENTER WITH ACCESSORY PARKING AS PREVIOUSLY APPROVED.SIZE AND LOCATIONS AS SHOWN IN APPLICATION/PLAN.

  86. PermitZoning/use

    Permit 401523 · COMPLETED

    APPLYING FOR FENCE, SHED FOR STORAGE AND SIGNAGE TO FOOD TRAILER. **VARIANCE FROM BOARD IS INCLUDED IN PACKAGE.**

  87. PermitPlumbing

    Permit 408905 · COMPLETED

    INSTALL HOT WATER HEATER, INSTALL FOOD SERVICE HOSE AND BACK FLOW PREVENTOR

  88. PermitZoning/use

    Permit 391857 · COMPLETED

    ERECT TRAILER FOR USE AS TAKE-OUT FOOD.

  89. AppealZoning board appeal

    Appeal 17667 · CLOSED · Granted with conditions

    Related permit 391857 · CERTIFICATE FOR THE ERECTION OF A ONE(1) STORY STRUCTURE (TRAILER) FOR USE AS A TAKEOUT RESTAURANT ON THE SAME LOT WITH AN EXISTING SHOPPING CENTER.

  90. PermitSign

    Permit 350891 · COMPLETED

    REMOVE EXISTING SIGN AND REPLACE WITH AN INT ILLUM FLAT WALL CHANNEL LETTER SIGN

  91. PermitSuppression

    Permit 284905 · COMPLETED

    RE-ELEVATE (4) SPRINKLERS

  92. PermitPlumbing

    Permit 280762 · COMPLETED

    PIPING & INSTALLNG 2 HAND SINKS, RELOCATE 6 TUB DRAINS FOR HOT & COLD BUFFET TABLES

  93. InvestigationCI INSP

    Case 59692 · PASSED

    The cited inspection visit was marked passed.

  94. InvestigationCI INSP

    Case 59683 · PASSED

    The cited inspection visit was marked passed.

  95. PermitPlumbing

    Permit 60084 · COMPLETED

    PROVIDE ALL NECESSARY PLUMBING WORK TO COMPLETE THE ABOVE SLAB INSTALLATION OF THE FOLLOWING FIXTURES, 1 WATER CLOSET, 1 LAV, 1 WATER COOLER AND 1 SLOP SINK, EXISTING WATER METER AND BACKFLOW PREVENTOR, CONNECT TO EXISTING VENT AND DOMESTIC WATER. NO WORK OUSIDE OF SPAVE ALL WORK UNDER SLAB ROUGHED IN BY OTHERS UNDER A SEPARATE PERMIT

  96. InvestigationBC INSP (likely: building-code inspection)

    Case 49470 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  97. InvestigationBC INSP (likely: building-code inspection)

    Case 49470 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  98. InvestigationBC INSP (likely: building-code inspection)

    Case 49470 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  99. InvestigationBC INSP (likely: building-code inspection)

    Case 49470 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  100. InvestigationBC INSP (likely: building-code inspection)

    Case 49470 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  101. InvestigationCI INSP

    Case 59692 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  102. InvestigationCI INSP

    Case 59683 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  103. InvestigationCI INSP

    Case 59683 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  104. InvestigationCI INSP

    Case 59692 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  105. InvestigationBC INSP (likely: building-code inspection)

    Case 49470 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  106. InvestigationL_CLIP

    Case 41508 · CLOSED

    City marked the record closed; open the case for the closing reason.

  107. InvestigationL_CLIP

    Case 41508 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 9:55 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)