Commercial property report

2400 Market St

11 stories600,523 sqftCMX4built 1929

Property at a glanceOffices

2400 Market Vii LP

2026 assessment
$152M OPA value, not a listing price
2027 published assessment
$151M Future roll, not the current tax bill
Neighborhood area
Rittenhouse · Logan Square Approximate · based on ZIP 19103
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $150,893,900. It is not yet the billed-year tax basis.

$0$100M$200M$151M2006201020142018202220262027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record261 events · exact dates, newest first
  1. PermitAddition and/or Alteration
  2. PermitAddition and/or Alteration
  3. PermitInterior Non-Load-Bearing Wall Demo.
  4. CertificationFire Alarm Certification
  5. CertificationFire Alarm Certification
  6. CertificationSprinkler Certification
  7. PermitAlterations
  8. CertificationSpecial Hazards Certification
  9. PermitNew construction, addition, GFA change
  10. CertificationSprinkler Certification
  11. CertificationSpecial Hazards Certification
  12. PermitTank Install/Removal
  13. PermitAddition and/or Alteration
  14. CertificationPrivate Bridge Report
  15. PermitAddition and/or Alterations
  16. CertificationFire Alarm Certification
  17. PermitAddition and/or Alteration
  18. PermitAddition and/or Alterations
  19. CertificationDamper Certification
  20. PermitAddition and/or Alteration
  21. PermitAddition and/or Alteration
  22. PermitAddition and/or Alteration
  23. CertificationSpecial Hazards Certification
  24. PermitInterior Non-Load-Bearing Wall Demo.
  25. CertificationFire Alarm Certification
  26. PermitAddition and/or Alteration
  27. PermitAddition and/or Alteration
  28. CertificationSprinkler Certification
  29. PermitAlterations
  30. CertificationSpecial Hazards Certification
  31. CertificationSpecial Hazards Certification
  32. CertificationSpecial Hazards Certification
  33. CertificationSpecial Hazards Certification
  34. PermitAddition and/or Alteration
  35. CertificationSpecial Hazards Certification
  36. LicenseFitler Club LLC: Rental landlord or residential registration initially issued
  37. CertificationFacade Report
  38. PermitNew construction, addition, GFA change
  39. PermitAddition and/or Alteration
  40. PermitAddition and/or Alteration
  41. PermitAddition and/or Alterations
  42. CertificationSpecial Hazards Certification
  43. PermitNew construction, addition, GFA change
  44. PermitChange of Use
  45. PermitSigns (Accessory / Non-Accessory)
  46. PermitSign
  47. CertificationSprinkler Certification
  48. PermitSigns (Accessory / Non-Accessory)
  49. LicenseFitler Club, LLC (Fitler Club): Food Preparing and Serving (30+ SEATS) business license marked inactive
  50. PermitMechanical
  51. PermitOperations
  52. PermitElectrical
  53. PermitElectrical
  54. PermitElectrical
  55. PermitPlumbing
  56. PermitPlumbing
  57. PermitSuppression
  58. PermitMechanical
  59. PermitZoning/use
  60. PermitMajor alteration
  61. PermitZoning/use
  62. PermitMajor alteration
  63. PermitSuppression
  64. PermitUse
  65. InspectionBP_BLDG
  66. PermitAdministrative
  67. PermitAdministrative
  68. PermitAdministrative
  69. PermitMechanical
  70. PermitElectrical
  71. PermitAdministrative
  72. PermitAdministrative
  73. PermitPlumbing
  74. PermitPlumbing
  75. PermitPlumbing
  76. PermitElectrical
  77. PermitElectrical
  78. PermitElectrical
  79. PermitElectrical
  80. PermitAdministrative
  81. PermitMechanical
  82. PermitMechanical
  83. PermitElectrical
  84. PermitElectrical
  85. InspectionBP_BLDG
  86. PermitElectrical
  87. PermitSuppression
  88. PermitAdministrative
  89. InspectionBP_BLDG
  90. InspectionBP_BLDG
  91. PermitMajor alteration
  92. PermitMajor alteration
  93. PermitMajor alteration
  94. PermitAdministrative
  95. LicenseFitler Club, LLC (Fitler Club): Food Preparing and Serving (30+ SEATS) business license initially issued
  96. InspectionBP_BLDG
  97. PermitMechanical
  98. PermitAdministrative
  99. InspectionBP_BLDG
  100. PermitElectrical
  101. InspectionCI INSP
  102. L&I violationARCHITECT/ENGINEER SERVICES
  103. L&I violationWORKMANLIKE- ELECTRICAL CODE
  104. InspectionBP_BLDG
  105. L&I violationLISTED CONDIT DOES NOT COMPLY
  106. L&I violationWORKMANLIKE- BUILDING CODE
  107. InspectionBP_BLDG
  108. InspectionBP_BLDG
  109. PermitElectrical
  110. L&I violationPERMB- FINAL PRE-CO INSP
  111. L&I violationFLOOD-SUBSTANTIAL IMPROVEMENT
  112. InspectionBP_BLDG
  113. PermitOperations
  114. PermitElectrical
  115. LicenseFitler Club LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
  116. PermitMechanical
  117. PermitPlumbing
  118. PermitAdministrative
  119. PermitAdministrative
  120. PermitElectrical
  121. PermitElectrical
  122. PermitElectrical
  123. PermitSuppression
  124. PermitAdministrative
  125. PermitUse
  126. PermitMajor alteration
  127. PermitSuppression
  128. PermitSuppression
  129. PermitSuppression
  130. PermitElectrical
  131. PermitAdministrative
  132. PermitAdministrative
  133. PermitAdministrative
  134. PermitAdministrative
  135. PermitAdministrative
  136. PermitAdministrative
  137. PermitAdministrative
  138. PermitSuppression
  139. PermitMajor alteration
  140. PermitMajor alteration
  141. PermitPlumbing
  142. PermitSuppression
  143. PermitAdministrative
  144. PermitAdministrative
  145. PermitSuppression
  146. PermitSuppression
  147. PermitMajor alteration
  148. PermitMajor alteration
  149. PermitMechanical
  150. PermitSign
  151. PermitSuppression
  152. PermitSuppression
  153. PermitSuppression
  154. PermitMechanical
  155. AppealBuilding standards appeal
  156. PermitElectrical
  157. PermitSuppression
  158. PermitMajor alteration
  159. PermitSuppression
  160. PermitSuppression
  161. AppealBuilding standards appeal
  162. PermitElectrical
  163. PermitPlumbing
  164. PermitZoning/use
  165. PermitElectrical
  166. PermitMechanical
  167. PermitSuppression
  168. PermitUse
  169. PermitMajor alteration
  170. PermitMajor alteration
  171. PermitMajor alteration
  172. PermitSuppression
  173. PermitElectrical
  174. PermitZoning/use
  175. PermitZoning/use
  176. L&I violationWORKMANLIKE- PLUMBING CODE
  177. AppealZoning board appeal
  178. PermitElectrical
  179. PermitMechanical
  180. PermitPlumbing
  181. PermitMajor alteration
  182. PermitZoning/use
  183. PermitZoning
  184. LicenseBISTRO ST TROPEZ: Food Preparing and Serving business license marked inactive
  185. PermitElectrical
  186. PermitAddition
  187. PermitElectrical
  188. PermitElectrical
  189. PermitMajor alteration
  190. InspectionEP_ELEC
  191. L&I violationLIC MUST BE AVAIL FOR INSP
  192. L&I violationLISTED CONDIT DOES NOT COMPLY
  193. L&I violationNOT CONFORM TO PRC/NEC
  194. L&I violationGROUND-SYSTEM PROPERLY
  195. L&I violationINSPECT-CONTR MUST ARRANGE
  196. InspectionEP_ELEC
  197. PermitMechanical
  198. PermitElectrical
  199. PermitPlumbing
  200. InspectionCI INSP
  201. PermitSuppression
  202. PermitMajor alteration
  203. PermitMajor alteration
  204. PermitElectrical
  205. L&I violationHAZMAT-LIC REQ¿D
  206. L&I violationHAZMAT-SPILL CLEAN-UP
  207. L&I violationF+C LIQ-PROVIDE CLOS RPT
  208. L&I violationF+C LIQ-LEAKING TANK
  209. L&I violationF+C LIQ-AG TNK-PROV OF SHUTOFF
  210. L&I violationVIOL C&I MESSAGE
  211. L&I violationHAZMAT-REM DEF CON+TNK REP/DIS
  212. InspectionCI INSP
  213. PermitElectrical
  214. PermitSuppression
  215. L&I violationWORKMANLIKE- BUILDING CODE
  216. PermitPlumbing
  217. PermitPlumbing
  218. PermitMajor alteration
  219. PermitSuppression
  220. PermitMechanical
  221. PermitPlumbing
  222. PermitMajor alteration
  223. PermitMajor alteration
  224. PermitAddition
  225. PermitDemolition
  226. PermitMajor alteration
  227. LicensePATRICE L RAMES (BISTRO ST TROPEZ INC): Food Preparing and Serving (30+ SEATS) business license marked inactive
  228. LicenseXO COMMUNICATIONS SERVICES INC (CHRIS SCHNAITHMAN): Hazardous Materials L&I license filing marked inactive
  229. PermitZoning/use
  230. LicensePHL HAUSBRANDT CAFE 2 LLC (ACADEMIA DEL CAFFEE): Food Preparing and Serving business license marked inactive
  231. LicenseBISTRO ST TROPEZ: Food Preparing and Serving business license initially issued
  232. PermitMajor alteration
  233. PermitSuppression
  234. LicenseMPDC LP: Dumpster License - Private Property L&I license filing marked inactive
  235. LicenseXO COMMUNICATIONS SERVICES INC (CHRIS SCHNAITHMAN): Hazardous Materials L&I license filing initially issued
  236. InspectionCI INSP
  237. LicenseMPDC LP: Dumpster License - Private Property L&I license filing initially issued
  238. InspectionCI INSP
  239. PermitElectrical
  240. PermitSuppression
  241. PermitElectrical
  242. PermitMajor alteration
  243. PermitUse
  244. PermitSuppression
  245. PermitMajor alteration
  246. PermitUse
  247. PermitFast form building
  248. PermitMechanical
  249. PermitElectrical
  250. PermitMajor alteration
  251. PermitSuppression
  252. LicensePATRICE L RAMES (BISTRO ST TROPEZ INC): Food Preparing and Serving (30+ SEATS) business license initially issued
  253. PermitMechanical
  254. PermitElectrical
  255. LicensePHL HAUSBRANDT CAFE 2 LLC (ACADEMIA DEL CAFFEE): Food Preparing and Serving business license initially issued
  256. PermitElectrical
  257. PermitElectrical
  258. PermitPlumbing
  259. PermitElectrical
  260. PermitPlumbing
  261. InspectionCI INSP

Verify the public record

$553,431/year estimated property tax

2026 taxable assessment $39,536,450 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $150,893,900. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 883054700
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $39,536,450 of $151,771,400 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Offices, recorded in the City's offices category. The public record and owner trail follow.

What it is
Offices Off Bld Com No Gar Mason
Owner
2400 Market Vii LP
$ / sq ft
$251 above the $142 median for 753 offices parcels citywide
Licensed units
14 active rental license
Interior area
600,523 sqft
Lot size
80,658 sqft
Stories
11
Built
1929
Zoning
CMX4

Recorded owner

Who's behind it

2400 Market Vii LP · corporate / LLC owner

• Owns 2 properties across Philadelphia under this name, assessed at $151M combined
• Tax bills mail to 2400 Market Street Ste 301, Philadelphia PA, 19103
• Holds an active rental license for this address

Block context

2400 block of Market St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 2416-18 Market St  ·  2417 Market St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
Fitler Club, LLC (Fitler Club)Inactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Apr 3, 2019 · Terminal license date Jun 1, 2020

Fitler Club LLCActive

Food Preparing and Serving (30+ SEATS) · Initial issue date Jan 30, 2019 · Filed expiration Jan 29, 2027

BISTRO ST TROPEZInactive

Food Preparing and Serving · Initial issue date Apr 12, 2012 · Terminal license date Jun 29, 2016

PATRICE L RAMES (BISTRO ST TROPEZ INC)Inactive

Food Preparing and Serving (30+ SEATS) · Initial issue date May 9, 2008 · Terminal license date Jun 29, 2015

PHL HAUSBRANDT CAFE 2 LLC (ACADEMIA DEL CAFFEE)Inactive

Food Preparing and Serving · Initial issue date Jul 26, 2007 · Terminal license date Dec 22, 2012

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

Fitler Club LLCActive

Rental · Initial issue date Oct 13, 2023 · Filed expiration Oct 12, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 261 dated rows
  1. PermitAddition and/or Alteration

    Permit CP-2026-002677 · Issued

    FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, FIXTURES, FURNISHINGS, DOORS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  2. PermitAddition and/or Alteration

    Permit CP-2026-001368 · Issued

    FOR INTERIOR ALTERATIONS AND THE STRUCTURAL WORK ASSOCIATED WITH THE REMOVAL OF COMMUNICATIVE STAIR SEGMENT THAT SPANS FROM 5TH TO 6TH FL. WITHIN AN EXISTING BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK.

  3. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2026-001570 · Issued

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  4. CertificationFire Alarm Certification

    Certification BC-2025-025484 · Certified

    Expires 2026-09-30

  5. CertificationFire Alarm Certification

    Certification BC-2025-018572 · Certified

    Expires 2026-07-11

  6. CertificationSprinkler Certification

    Certification BC-2025-018574 · Certified

    Expires 2026-07-11

  7. PermitAlterations

    Permit PP-2025-001364 · Completed

    INSTALLATION OF NEW STORM DRAINAGE CONNECTING TO STORMWATER MAIN PER PROVIDED PLANS AND IN COMPLIANCE WITH 2018 PPC.

  8. CertificationSpecial Hazards Certification

    Certification BC-2025-016423 · Certified

    Expires 2026-03-26

  9. PermitNew construction, addition, GFA change

    Permit ZP-2024-012027 · Completed

    *FOR NO CHANGES TO EXISTING STRUCTURES, NO CHANGE IN AREA. NO CHANGE IN HEIGHT* FOR THE INSTALLATION OF A RETRACTABLE CANOPY OVER AN EXISTING COURTYARD AS A PART OF AN EXISTING ENTERTAINMENT AND ASSEMBLY WITH ALL OTHER USES AS PREVIOUSLY APPROVED ON THE EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLAN. (NO SIGN ON THIS PERMIT), (FOR UNITY OF USE APPROVED, SEE PERMIT # ZP-2022-002708)

  10. CertificationSprinkler Certification

    Certification BC-2025-001283 · Certified

    Expires 2025-11-15

  11. CertificationSpecial Hazards Certification

    Certification BC-2024-029570 · Certified

    Expires 2025-10-31

  12. PermitTank Install/Removal

    Permit GP-2024-008645 · Completed

    FOR THE DISCONTINUANCE OF THE EXISTING 5,000 GALLON UNDERGROUND TANK (CLOSED-IN-PLACE). ALL WORK TO BE DONE IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS, PENNSYLVANIA D.E.P REGULATIONS, AND ALL APPLICABLES CODES, NFPA 30 AND NFPA 31.

  13. PermitAddition and/or Alteration

    Permit EP-2024-008348 · Completed

    INSTALLATION OF TELECOMMUNICATIONS WIRING FOR VIDEO STUDIO ACCORDING TO THE 2017 NEC.

  14. CertificationPrivate Bridge Report

    Certification BC-2024-023659 · Safe

    Expires 2029-08-23

  15. PermitAddition and/or Alterations

    Permit MP-2024-003474 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  16. CertificationFire Alarm Certification

    Certification BC-2024-021922 · Certified

    Expires 2025-08-01

  17. PermitAddition and/or Alteration

    Permit EP-2024-007141 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  18. PermitAddition and/or Alterations

    Permit FP-2024-001499 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (20) SPRINKLER HEADS AS PER NFPA 13

  19. CertificationDamper Certification

    Certification BC-2024-020613 · Certified

    Expires 2028-07-18

  20. PermitAddition and/or Alteration

    Permit CP-2024-003490 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN OCCUPANCY TO CREATE A GROUP B VIDEO STUDIO AT THE 5TH FLOOR. EXISTING BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK.

  21. PermitAddition and/or Alteration

    Permit EP-2024-005012 · Completed

    Relocate and test (3) fire alarm devices.

  22. PermitAddition and/or Alteration

    Permit CP-2024-002338 · Expired

    FOR LEVEL II INTERIOR ALTERATIONS AT THE 6TH FLOOR NORTHEAST CORNER WITH NO CHANGE TO GROUP B USE & OCCUPANCY CLASSIFICATION. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK.

  23. CertificationSpecial Hazards Certification

    Certification BC-2024-012324 · Certified

    Expires 2025-04-30

  24. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2024-003650 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  25. CertificationFire Alarm Certification

    Certification BC-2024-007431 · Certified

    Expires 2025-03-20

  26. PermitAddition and/or Alteration

    Permit EP-2024-002032 · Completed

    Selective demo as needed. Relocate existing fixtures as needed. Furnish and install power for new devices.. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT**

  27. PermitAddition and/or Alteration

    Permit EP-2024-001651 · Completed

    Furnish & Install (20-25) Category 6A Plenum Cables for Voice & Data Demo Cubicle Cabling for (35-40) Cubicles

  28. CertificationSprinkler Certification

    Certification BC-2024-014341 · Certified

    Expires 2025-02-14

  29. PermitAlterations

    Permit PP-2023-017230 · Completed

    AMENDED 5.23.24 TO ADD AREA DRAIN. INSTALL 1 GRINDER PUMP WITH NECESSARY PIPING AND 3 BACKWATER VALVES ACCORDING TO THE 2018 PPC AND PER PLANS. AMENDMENT 9/11/2024 Instead of the original Sewage Ejector outside the West exterior wall, there will be (1) moved inside into what was a Storage Room previously. This Ejector will still be extended and connected to the Sewage Piping that the original Ejector was connecting into. There will be a 2nd Sewage Ejector added along with a new Grease Interceptor installed inside a Fitler Club Storage Room towards the Northwest corner of the building. This will be connected to other existing Sanitary piping that was previously installed but never actually used. As per attached new plans

  30. CertificationSpecial Hazards Certification

    Certification BC-2024-003232 · Certified

    Expires 2025-01-04

  31. CertificationSpecial Hazards Certification

    Certification BC-2024-003235 · Certified

    Expires 2025-01-04

  32. CertificationSpecial Hazards Certification

    Certification BC-2024-003227 · Certified

    Expires 2025-01-04

  33. CertificationSpecial Hazards Certification

    Certification BC-2024-003230 · Certified

    Expires 2025-01-04

  34. PermitAddition and/or Alteration

    Permit CP-2023-006284 · Completed

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) TO VERICALLY EXTEND EXISTING DRY FLOODPROOFING WALLS AS PER APPROVED PLANS. *2018 IEBC REVIEW* AMENDMENT APPROVED 3/7/24 AMEND ALTERATIONS PERMIT CP-2023-006284 TO INCLUDE EQUIPMENT PIT BEYOND DRY FLOODPROOFING WALLS AS PER APPROVED PLANS. *SEPARATE PERMIT REQUIRED FOR PLUMBING WORK*

  35. CertificationSpecial Hazards Certification

    Certification BC-2023-024292 · Certified

    Expires 2024-11-13

  36. License issue eventFitler Club LLC: Rental landlord or residential registration initially issued

    License 935607 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  37. CertificationFacade Report

    Certification BC-2023-020600 · Safe with Repair

    Expires 2028-08-29

  38. PermitNew construction, addition, GFA change

    Permit ZP-2022-010882 · Completed

    FOR ERECTION OF ROOF COVERS ABOVE THE EXISTING WALKWAYS OPEN-AIR BRIDGE CONNECTING THE BUILDING TO THE GARAGE STRUCTURE AND A MARQUEE STRUCTURE ALONG THE EXISTING WALKWAY ABOVE 24TH STREET AS PER CITY STREET DEPARTMENT APPROVAL AND ART COMMISSION APPROVAL (NO SIGNAGE ALLOWED). SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLANS.

  39. PermitAddition and/or Alteration

    Permit EP-2022-012854 · Completed

    INSTALL A NEW NAC BOOSTER PANEL AND FIRE ALARM DEVICES TO THE EXISTING BUILDING FIRE ALARM SYSTEM. ALL WORK IN ACCORDANCE WITH THE 2017 NEC & 2016 NFPA-72.

  40. PermitAddition and/or Alteration

    Permit EP-2022-010383 · Completed

    Data Cabling Install 94 CAT-6A cables, 46 speaker, 7 volume control, 4 coax cable as per 2017 nec

  41. PermitAddition and/or Alterations

    Permit FP-2022-002824 · Completed

    FOR ALTERATIONS TO AN EXISTING AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT RENOVATED SPACE AT THE 1ST FLOOR. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13 BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2022-002364 FOR ASSOCIATED BUILDING ALTERATIONS PERMIT.

  42. CertificationSpecial Hazards Certification

    Certification BC-2022-007117 · Certified

    Expires 2023-05-12

  43. PermitNew construction, addition, GFA change

    Permit ZP-2022-000396 · Issued

    *FOR NO CHANGES TO EXISTING STRUCTURES, NO CHANGE IN AREA. NO CHANGE IN HEIGHT* FOR TO CHANGE THE USE OF THE VACANT TENANT SPACES TO BUSINESS AND PROFESSIONAL OFFICE ON FIRST FLOOR. ALL OTHER USES AS PREVIOUSLY APPROVED ON EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLAN. (FOR UNITY OF USE APPROVED, SEE PERMIT # ZP-2022-002708)

  44. PermitChange of Use

    Permit ZP-2022-002708 · Issued

    Unity of Use

  45. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2021-012659 · Completed

    FOR THE ERECTION OF TWO (2) CABINET SIGNS. SIZE AND LOCATION AS SHOWN IN PLAN.

  46. PermitSign

    Permit GP-2021-006199 · Completed

    FOR THE ERECTION OF ONE (1) ACCESSORY CABINET SIGN. SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLANS. ELECTRICAL WORK REQUIRES A SEPARATE PERMIT.

  47. CertificationSprinkler Certification

    Certification BC-2021-004146 · Certified

    Expires 2022-08-19

  48. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2021-006872 · Completed

    FOR THE ERECTION OF ONE (1) ACESSORY CABINET SIGN. SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLANS.

  49. License terminal eventFitler Club, LLC (Fitler Club): Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 808123 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  50. PermitMechanical

    Permit 1041543 · COMPLETED

    MECHANICAL ALTERATIONS ON THE THIRD FLOOR OFFICE SPACE, TO INCLUDE THE INSTALLATION OF THREE (3) FCU'S WITH REGISTERS/DIFFUSERS AND ASSOCIATED DUCTWORK, AS PER APPROVED PLANS.

  51. PermitOperations

    Permit 26730 · COMPLETED

    ERECT ONE(1) 20'X 70' TENT 12/12/2019 DATE OF EVENT;12/13/2019 REMOVED ON 12/15/2019

  52. PermitElectrical

    Permit 1035582 · COMPLETED

    INSTALL WIRING FOR TENANT FITOUT INSTALL DEVICES AND FIXTURES THROUGHOUT AS PER APPROVED LAYOUT PER 2008 NEC (CC DIST)

  53. PermitElectrical

    Permit 1028828 · COMPLETED

    TENANT OFFICE ELECTRICAL POWER AND LIGHTING INSTALLATION AS PER ATTACHED PLANS. INSTALLATION OF FIRE ALARM DEVICES AS PER ENGINEERED PLANS-INSTALLATION OF 100AMP PANEL AND 30KVA XMFR AS PER PLANS

  54. PermitElectrical

    Permit 1018505 · COMPLETED

    INSTALLATION OF NEW FIRE ALARM DEVICES AND FIRE ALARM CABLE AS PER ATTACHED PLANS

  55. PermitPlumbing

    Permit 1027451 · COMPLETED

    INSTALL WASTE AND WATER LINES TO 1-KITCHEN SINK ONLY.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004 - THE INSTALLATION DOES NOT INCLUDE GARBAGE DISPOSAL OR DISHWASHER

  56. PermitPlumbing

    Permit 1021004 · COMPLETED

    INSTALL SINK/WATER HEATER/TRAP PRIMER AND SAN/DEM WATER PIPE **BUILDING AP# 1004006. INSTALLATION SHALL COMPLY WITH PHILDELPHUA PLUMBING CODE 2004 6TH PRINTING

  57. PermitSuppression

    Permit 1024275 · COMPLETED

    RELOCATE 20 EXISTING SPRINKLER HEADS.

  58. PermitMechanical

    Permit 1018058 · COMPLETED

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  59. PermitZoning/use

    Permit 1010473 · COMPLETED

    FOR THE ERECTION OF TWO(2) SINGLE-FACED ILLUMINATED FLATWALL SIGNS AND SEVEN(7) NON ILLUMINATED FLATWALL SIGNS. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS. SIGNS ACCESSORY TO A PREVIOUSLY APPROVED MIXED USE STRUCTURE.

  60. PermitMajor alteration

    Permit 1011750 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) TO THE 3RD FLOOR OF AN EXISTING STRUCTURE AS PER APPROVED PLANS**EXISTING BUILDING FULLY SPRINKLERED**SEPARATE PERMIT REQUIRED FOR ANY MECHANICAL, ELECTRICAL, PLUMBING OR FIRE SUPPRESSION WORK**IEBC 2018**

  61. PermitZoning/use

    Permit 1001015 · COMPLETED

    INSTALL (3) D/F ILLUMINATED TENANT PYLON 9'H X 4'-6"W=40.5 SF

  62. PermitMajor alteration

    Permit 1004006 · COMPLETED

    FOR LEVEL II ALTERATIONS TO EXISTING TENANT SPACE LOCATED ON THE FIRST FLOOR LEVEL (ART GALLERY) AND THIRD FLOOR (BUSINESS OCCUPANCY) TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  63. PermitSuppression

    Permit 1014124 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)-RELOCATE 84 SPRINKLER HEADS OF AN EXISTING SYSTEM TO ACCOMMODATE NEW LAYOUT FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  64. PermitUse

    Permit 1011896 · COMPLETED

    USE CHANGE OF 1ST FLR SUIT #100 FROM COMMERCIAL TO GALLERY ARTIST STUDIOS AND ARTISAN INDUSTRIAL AS PART OF AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT

  65. InvestigationBP_BLDG

    Case 673738 · PASSED

    The cited inspection visit was marked passed.

  66. PermitAdministrative

    Permit 998876 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  67. PermitAdministrative

    Permit 998891 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  68. PermitAdministrative

    Permit 998152 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  69. PermitMechanical

    Permit 984965 · COMPLETED

    FOR MECHANICAL ALTERATIONS TO THE SECOND FLOOR OF AN EXISTING OFFICE BUILDING TO INCLUDE NEW VRF UNITS, REFRIGERANT PIPING, REGISTERS/DIFFUSERS AND ASSOCIATED DUCTWORK, AS PER APPROVED PLANS.

  70. PermitElectrical

    Permit 973291 · COMPLETED

    INSTALL AUDIO VISUAL EQUIPMENT SPEAKES VIDEO PROJECTORS TV MONITORS VIDEO WALL CAMERAS PULL LOW VOLTAGE CABLE FOR AUDIO VISUAL TERMINATE EQUIPMENT RACKS (TOTAL OF 6)PER 2008 NEC

  71. PermitAdministrative

    Permit 987762 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  72. PermitAdministrative

    Permit 987801 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  73. PermitPlumbing

    Permit 987031 · COMPLETED

    INSTALLING 2 KITCHEN SINKS, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004

  74. PermitPlumbing

    Permit 987027 · COMPLETED

    INSTALLING 2 KITCHEN SINKS, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004

  75. PermitPlumbing

    Permit 987023 · COMPLETED

    INSTALLING 1 KITCHEN SINK, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004

  76. PermitElectrical

    Permit 971551 · COMPLETED

    FURNISH AND INSTALL DISTRIBUTION, LIGHTING, BRANCH WIRING, MEP FEEDS AND CONNECTIONS AS PER PLANS. FIRE ALARM SYSTEM PER NFPA 72. REF BUILDING PERMIT #938607

  77. PermitElectrical

    Permit 977842 · ABANDONED

    TENANT FITOUT. ELECTRICAL SERVICE FROM EXISTING PANEL, INSTALL NEW LIGHTING, RECEPTACLES, SWITCHES, EQUIPMENT CONNECTIONS & BRANCH WIRING AS PER 2008 NEC(CC DIST) PER ATTACHED PLANS. FIRE ALARM ALTERATIONS TO EXISTING FIRE ALARM SYSTEM PER NFPA 72.COMMUNICATIONS. ALL NEW VOICE AND DATA CABLING AND CONNECTIONS. BUILDING PERMIT#916597

  78. PermitElectrical

    Permit 979753 · COMPLETED

    INSTALLATION OF LOW VOLTAGE OF CATEGORY 6 CABLES FOR COMPUTERS FOR 100 LOCATIONS AS PER 2017 NEC (CC DISTRICT)

  79. PermitElectrical

    Permit 979754 · COMPLETED

    INSTALLATION OF LOW VOLTAGE OF CATEGORY 6 CABLES FOR COMPUTERS FOR 60 LOCATIONS AS PER 2017 NEC (CC DISTRICT)

  80. PermitAdministrative

    Permit 915658 · COMPLETED

    FOR THE AMENDMENT OF PERMIT AP#745717 TO ERECT DRY FLOOD-PROOFING STRUCTURES, TO INCLUDE FLOOD BARRIER INSTALLATION, MULLION ANCHORAGE, EXTERIOR MASONRY WALLS, STEEL FRAMING REINFORCEMENT, AND PROPOSED SUMP PUMP INSTALLATIONS. **SEPARATE PERMIT REQ'D FOR ANY PLUMBING WORK. FLOOD BARRIER GATES TO BE MAINTAINED ON SITE AND REGULARLY INSPECTED PER FLOOD EMERGENCY OPERATIONS PLAN. FLOOD EMERGENCY OPERATIONS PLAN TO BE MAINTAINED ON SITE.**

  81. PermitMechanical

    Permit 971579 · COMPLETED

    FOR THE INSTALLATION OF REGISTERS, DIFFUSER AND APPLIANCES WITH ASSOCIATED DUCTWORK IN AN EXISTING BUSINESS OCCUPANCY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTIANED FOR ALL OTHER WORK.

  82. PermitMechanical

    Permit 970585 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR THIRD FLOOR OFFICE SPACE (LEM CAPITAL) IN AN EXISTING BUILDING AS PER APPROVED PLANS.

  83. PermitElectrical

    Permit 971547 · COMPLETED

    COMPLETE OFFICE FITOUT EXISTING BUILDING @3RD FLOOR, INCLUDING SERVICE, POWER AND LIGHTING PER 2008 NEC. TELEDATA ROUGH IN ONLY PER PLANS. FIRE ALARM PER NFPA 72. BUILDING PERMIT #927582 (CC DIST)

  84. PermitElectrical

    Permit 971542 · COMPLETED

    COMPLETE OFFICE FITOUT EXISTING BUILDING @3RD FLOOR, INCLUDING SERVICE, POWER AND LIGHTING PER 2008 NEC. TELEDATA ROUGH IN ONLY PER PLANS. FIRE ALARM PER NFPA 72. BUILDING PERMIT #923666 (CC DIST)

  85. InvestigationBP_BLDG

    Case 674628 · PASSED

    The cited inspection visit was marked passed.

  86. PermitElectrical

    Permit 969840 · COMPLETED

    INSTALLATION OF LOW VOLTAGE CATEGORY 6 CABLES FOR COMPUTERS TO 70 LOCATIONS. PER 2017 NEC

  87. PermitSuppression

    Permit 949073 · COMPLETED

    FOR THE EXTENSION OF AN EXISTING FIRE SUPPRESSION SYSTEM INTO A TENANT SPACE AT THE FOURTH FLOOR (GROUPS A-3/B/S-2 OCCUPANCIES) OF AN EXISTING HIGH-RISE STRUCTURE IN ACCORDANCE WITH NFPA 13. FIRE SUPPRESSION SYSTEM TO BE SERVICED BY A SIX INCH FEED MAIN AND SIX INCH SUPPLY RISER WITH AN EXISTING BACKFLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  88. PermitAdministrative

    Permit 966908 · COMPLETED

    FOR AN AMENDMENT TO PREVIOUSLY ISSUED ALTERATIONS PERMIT AP#906686 TO REVISE FLOOR LAYOUT, FINISHES, AND FURNITURE LAYOUTS, AS PER REVISED PLANS; NO OTHER CHANGES ON THIS PERMIT.

  89. InvestigationBP_BLDG

    Case 673937 · PASSED

    The cited inspection visit was marked passed.

  90. InvestigationBP_BLDG

    Case 673938 · PASSED

    The cited inspection visit was marked passed.

  91. PermitMajor alteration

    Permit 923666 · COMPLETED

    LEVEL II ALTERATION FOR TENANT FIT-OUT.

  92. PermitMajor alteration

    Permit 927582 · COMPLETED

    LEVEL II ALTERATION FOR TENANT FIT-OUT OF LEM CAPITAL SPACE. ** SEPARATE PERMIT REQUIRED FOR M.E.P.S.**

  93. PermitMajor alteration

    Permit 938607 · COMPLETED

    PARTIAL INTERIOR ALTERATION OF 2ND FLOOR WITHIN AN EXISTING BUILDING. PROJECT AREA IS 29,671 SF. WORK INCLUDES: SELECT DEMOLITION OF INTERIOR NON LOAD BEARING, NON FIRE RATED PARTITIONS AND DOORS: ERECTION OF INTERIOR NON LOAD BEARING, NON FIRE RATED PARTITIONS: INSTALLATION OF INTERIOR CEILINGS, FIXTURES, INTERIOR DOORS, FINISHES AND CABINTRY. NO STRUCTUREAL WORK NO SPECIAL INSPECTIONS REQUIRED. NO CHANGE IN USE. ** SEPARATE PERMIT REQUIRED FOR M.E.P.S **

  94. PermitAdministrative

    Permit 964697 · COMPLETED

    TEMOORARY CERTIFICATE OF OCCUPANCY

  95. License issue eventFitler Club, LLC (Fitler Club): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 808123 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  96. InvestigationBP_BLDG

    Case 674628 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  97. PermitMechanical

    Permit 933999 · COMPLETED

    ALTERATIONS TO A MECHANICAL SYSTEM TO INCLUDE FIVE (5) AIR HANDLING UNITS, REGISTERS, DIFFUSERS AND ASSOCIATED DUCTWORK.

  98. PermitAdministrative

    Permit 952137 · COMPLETED

    FOR THE AMENDMENT OF PERMIT AP#745717 TO REVISE EXISTING BUILDING PERMIT DOCUMENTATION TO PROVIDE FLOOD PROTECTION AT EXISTING SPRINKLER ROOM, TO INCLUDE ENGINEERED FLOOD BARRIER INSTALLATIONS, GASKET INSTALLATIONS AT BARRIER OBSTRUCTIONS, POST-INSTALLED CONCRETE ANCHOR INSTALLATIONS, STEEL SUPPORT POSTS, INTERIOR STAIR INSTALLATION, NEW ELEVATED DOORWAY, AND SUMP PUMP INSTALLATION. **SEPARATE PERMITS TO BE REQUIRED FOR ANY PLUMBING AND ELECTRICAL WORK.**

  99. InvestigationBP_BLDG

    Case 673738 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  100. PermitElectrical

    Permit 949849 · COMPLETED

    COMPLETE OFFICE FIT OUT IN EXISTING BUILDING @ 3RD FLOOR, STE 300 INCLUDING SERVICE POWER AND LIGHTING PER 2008 NEC. TELEDATA ROUGH IN ONLY PE RPLANS FIRE ALARM PER NFPA72

  101. InvestigationCI INSP

    Case 517529 · PASSED

    The cited inspection visit was marked passed.

  102. ViolationARCHITECT/ENGINEER SERVICES

    Case 674628 · Violation 4991779 · Code A-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  103. ViolationWORKMANLIKE- ELECTRICAL CODE

    Case 674628 · Violation 4991778 · Code A-104.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  104. InvestigationBP_BLDG

    Case 674628 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  105. ViolationLISTED CONDIT DOES NOT COMPLY

    Case 673938 · Violation 4954058 · Code A-501.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  106. ViolationWORKMANLIKE- BUILDING CODE

    Case 673938 · Violation 4954057 · Code A-104.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  107. InvestigationBP_BLDG

    Case 673937 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  108. InvestigationBP_BLDG

    Case 673938 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  109. PermitElectrical

    Permit 949904 · COMPLETED

    FURNISH AND INSTALL 1559 CAT 6 PLENUM CABLES FOR VOICE AND DATA 57 RG6 PLENUM COAX FOR TV AND 16/3 FOR SOUND MASKING LOW VOLTAGE

  110. ViolationPERMB- FINAL PRE-CO INSP

    Case 673937 · Violation 4954054 · Code A-402.5/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  111. ViolationFLOOD-SUBSTANTIAL IMPROVEMENT

    Case 673738 · Violation 4985244 · Code A-302.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  112. InvestigationBP_BLDG

    Case 673738 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  113. PermitOperations

    Permit 26086 · COMPLETED

    01/22/19 ERECT TENT: 20X70

  114. PermitElectrical

    Permit 939332 · COMPLETED

    INSTALL 71 NEW SPEAKER STROBES, 2 DUAL INPUT MODULES, 162 SINGLE INPUT MODULE WITH PROGRAMMABLE RELAY, 146 DUCT HOUSING WITH RELAY, 146 SMOKEDETECTORS AS PER NFPA 72 (CC DIST)

  115. License issue eventFitler Club LLC: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 801039 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  116. PermitMechanical

    Permit 935851 · COMPLETED

    INSTALLATION OF A NEW HVAC SYSTEM INCLUDING NEW VRF REFRIGERATION SYSTEM WITH DUCTWORK, PIPING AND CONTROLS FOR HVAC AND CRA UNITS FOR COMPUTER COOLING AS PER PLANS.

  117. PermitPlumbing

    Permit 935844 · COMPLETED

    ALTERATIONS, WITH A PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION, FROM GROUPS A-3/M THROUGHOUT THE FOURTH FLOOR (FURNITURE SHOWROOM, RESTAURANT), TO GROUPS A-3/B/S-2 (OFFICES, RADIO/TV STUDIOS), ON THE ENTIRE FOURTH FLOOR OF AN EXISTING HIGH-RISE STRUCTURE; OFFICE FIT OUT ON 4TH FLR OF 9 STORY BLDG. EXTENSION OF EXISTING PLUMBING SYSTEM FOR NEW INSTALLATION. THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004.

  118. PermitAdministrative

    Permit 940903 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  119. PermitAdministrative

    Permit 940878 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  120. PermitElectrical

    Permit 929813 · COMPLETED

    EXTEND LANDLORD PROVIDED BRANCH CIRCUITS TO SPACE TO FINAL CONNECTION POINTS AND DEVICE LOCATIONS,INSTALL OUTLETS AND MAKE FINAL CONNECTIONS AS PER 2008 NEC (CC DISTRICT)

  121. PermitElectrical

    Permit 933316 · COMPLETED

    INSTALL LIGHTING FIXTURES, RECEPTACLES AND POWER PER PLANS AND SPECS AS PER 2008 NEC(CC DIST)

  122. PermitElectrical

    Permit 923581 · COMPLETED

    ELECTRICAL WORK AS NEEDED FOR INTERCONNECTION STAIRCASE AND 5-CIRCUITS FOR 5-MOTORS AS PER NEC 2008 CC DISTRICT

  123. PermitSuppression

    Permit 934045 · COMPLETED

    FAST FORM PERMIT: RELOCATING (50) SPRINKLER HEADS TO ACCOMMODATE NEW WALL AND CEILING LAYOUT.

  124. PermitAdministrative

    Permit 916602 · COMPLETED

    AMENDMENT TO PERMIT APPLICATION #745717 FOR THE FOLLOWING CHANGES: LEVEL 0: INTERIOR ALTERATIONS TO ACCOMMODATE PROPOSED OFFICE, CONTAINING A LOCKER ROOM, ENGINEERING ROOM AND JANITOR'S STORAGE ROOM. LEVEL 1: INTERIOR ALTERATIONS TO ACCOMMODATE PROPOSED OFFICE AND REVISED LAYOUT OF CORRIDOR. SEPARATE PERMIT REQUIRED FOR CERTIFICATE OF OCCUPANCY.

  125. PermitUse

    Permit 923409 · COMPLETED

    FOR USE OF RADIO, TELEVISION, AND RECORDING SERVICES, AND BUSINESS AND PROFESSIONAL OFFICES, ON THE ENTIRE FOURTH FLOOR OF AN EXISTING ATTACHED STRUCTURE; NO CHANGES TO PREVIOUSLY APPROVED ADDITIONS, USES, OR PARKING, ON PERMITS AP#833696, 815720, 757768, OR 741708 ON THIS PROPERTY.

  126. PermitMajor alteration

    Permit 906686 · COMPLETED

    FOR LEVEL II ALTERATIONS, WITH A PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION, FROM GROUPS A-3/M THROUGHOUT THE FOURTH FLOOR (FURNITURE SHOWROOM, RESTAURANT), TO GROUPS A-3/B/S-2 (OFFICES, RADIO/TV STUDIOS), ON THE ENTIRE FOURTH FLOOR OF AN EXISTING HIGH-RISE STRUCTURE CURRENTLY UNDER RENOVATION, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING TO BE FULLY SPRINKLERED THROUGHOUT IN ACCORDANCE WITH NFPA 13 AND WITH STANDPIPES WITHIN EXIT STAIRWAYS IN ACCORDANCE WITH NFPA 14; NO SIGNS ON THIS PERMIT; SEE AP#745717 FOR BUILDING PERMIT OF SHELL SPACE; NO EXTERIOR WORK.

  127. PermitSuppression

    Permit 931590 · COMPLETED

    RELOCATING 50 SPRINKLER HEADS.

  128. PermitSuppression

    Permit 931588 · COMPLETED

    RELOCATING 50 SPRINKLER HEADS.

  129. PermitSuppression

    Permit 930611 · COMPLETED

    RELOCATING 24 SPRINKLER HEADS IN THE ATRIUM & UNDER THE STAIRS.

  130. PermitElectrical

    Permit 868100 · COMPLETED

    FURNISH AND INSTALL DISTRIBUTION,BRANCH WIRING,MEP FEEDS AND CONNECTIONS AND TELECOMMUNICATIONS PER 2008 NEC (COMMERCIAL)FIRE ALARM SYSTEM PER NFPA 72

  131. PermitAdministrative

    Permit 927858 · COMPLETED

    TCO 5TH FLOOR ONLY

  132. PermitAdministrative

    Permit 928108 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  133. PermitAdministrative

    Permit 927807 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  134. PermitAdministrative

    Permit 928111 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  135. PermitAdministrative

    Permit 928113 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  136. PermitAdministrative

    Permit 928114 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  137. PermitAdministrative

    Permit 928112 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  138. PermitSuppression

    Permit 928162 · COMPLETED

    INSTALL 4 ANSUL R102 WET CHEMICAL SYSTEMS IN OFFICE CAFETERIA.

  139. PermitMajor alteration

    Permit 916597 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A MERCANTILE SPACE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, AND PROVIDE FINISHES THROUGHOUT. SEPARATE PERMIT REQUIRED FOR CERTIFICATE OF OCCUPANCY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  140. PermitMajor alteration

    Permit 915538 · COMPLETED

    **3RD FLR LOCATED HIGHER THAN BFE+18"** FOR LEVEL II ALTERATIONS WITH A PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION FROM GROUPS M/S-1 (FURNITURE SHOWROOM/RETAIL), TO GROUP B (OFFICES), WITHIN SUITE 300 ON THE 3RD FLR OF AN EXISTING HIGH-RISE STRUCTURE CURRENTLY UNDER RENOVATION, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING TO BE FULLY SPRINKLERED THROUGHOUT IN ACCORDANCE WITH NFPA 13 AND WITH STANDPIPES WITHIN EXIT STAIRWAYS IN ACCORDANCE WITH NFPA 14; NO SIGNS ON THIS PERMIT; SEE AP#745717 FOR BUILDING PERMIT OF SHELL SPACE; NO EXTERIOR WORK.

  141. PermitPlumbing

    Permit 882832 · COMPLETED

    INTERIOR FITOUT OF EXISTING BUILDING - BATHROOMS, KITCHENS, LOCKER ROOMS AND HOTEL ROOMS THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  142. PermitSuppression

    Permit 918110 · COMPLETED

    RELOCATION OF 60 EXISTING SPRINKLER HEADS

  143. PermitAdministrative

    Permit 916621 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  144. PermitAdministrative

    Permit 887913 · COMPLETED

    FOR THE AMENDMENT OF AP# 745717 FOR THE FIT OUT OF TERRACE LEVEL 7 AS PER PLANS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMIT TO BE OBTAINED FOR CERTIFICATE OF OCCUPANCY AFTER FLOOD PLAIN PROVISION ARE MET.

  145. PermitSuppression

    Permit 877988 · COMPLETED

    FOR THE INSTALLATION OF UL 300 LISTED WET CHEMICAL EXTINGUISHING SYSTEM WITH THIRTY (30) FLOW POINTS IN ACCORDANCE WITH NFPA 17A. FIRE SUPRESSION SYSTEM TO SERVE A COMMERCIAL KITCHEN EXHAUST HOOD SYSTEMS.***PLEASE SEE AP#890139 FOR APPROVED KITCHEN HOOD/VENTILATION SYSTEM.***

  146. PermitSuppression

    Permit 893452 · COMPLETED

    RELOCATION OF (193) SPRINKLER HEADS.

  147. PermitMajor alteration

    Permit 881297 · COMPLETED

    INTERIOR ALTERATIONS AND STRUCTURAL WORK TO FLOOR 5 - 9 OF AN OFFICE BUILDING TO CONSTRUCT A 5-STORY ATRIUM AND CONNECTING STAIRS AS PER APPROVED PLANS AND BBS VARIANCE CASE NO. 33256. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  148. PermitMajor alteration

    Permit 880964 · COMPLETED

    INTERIOR ALTERATIONS FOR AN OFFICE FIT-OUT AT THE 9TH FLOOR LEVEL. WORK TO INCLUDE UPGRADES TO FINISHES, NEW NON LOAD BEARING PARTITIONS, CEILING WORK, AND ALL OTHER WORK AS PER APPROVED PLANS. WORK LIMITED TO 9TH FLOOR ONLY. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. *NO CERTIFICATE OF OCCUPANCY ON THIS PERMIT; SEPARATE AMENDED BUILDING PERMIT REQUIRED FOR CERTIFICATE OF OCCUPANCY*

  149. PermitMechanical

    Permit 890139 · COMPLETED

    INSTALL ONE TYPE 1 HOOD ON LEVEL 0 TWO TYPE 1 HOODS AND ONE TYPE 2 HOODS ON LEVEL 2 AS PER PLANS.

  150. PermitSign

    Permit 871133 · COMPLETED

    FOR THE ERECTION OF FOUR (4) STATICALLY ILLUMINATED, FLAT WALL BUILDING IDENTIFICATION SIGNS ( BOTTOM EDGE OF SIGNS TO BE MIN 150' HIGH AND DO NOT EXTEND ABOVE THE ROOF LINE) FOR USE AS SIGNS ACCESSORY TO EXISTING BUSINESS AND PROFESSIONAL OFFICES IN THE SAME BUILDING WITH OTHER PREVIOUSLY APPROVED USES AND SIGNS.SIZE AND LOCATION AS SHOWN IN APPLICATION. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. ALL WORK TO BE DONE ABOVE BFE +18".

  151. PermitSuppression

    Permit 858819 · COMPLETED

    **SEPARATE PERMIT REQUIRED FOR INSTALLATION OF SPRINKLERS WITHIN MEZZANINE/LEVEL 0.5** FOR ALTERATIONS TO A PREVIOUSLY-APPROVED AUTOMATIC WET SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH NFPA 13 UNDER AP#766437, CONNECTING TO THE OVERALL FIRE SUPPRESSION SYSTEM USING TWO (2), 8" FIRE SERVICE LINES W/TWO (2), 8" BACKFLOW PREVENTION DEVICES, ONE (1) FIRE PUMP WITHIN THE BASEMENT, AND THREE (3), 4" AUTOMATIC WET STANDPIPES WITHIN THE EXIT STAIRWAYS, CHANGING SPRINKLER LAYOUT AND INSTALLING NEW SPRINKLERS WITHIN LEVEL 0.0 FOR NEW "FITLER CLUB" TENANT, BY MOUNTING SPRINKLERS TO UNDERSIDE OF NEW MEZZANINE/LEVEL 0.5, AS PER PLANS; SEE AP#825994 FOR BUILDING PERMIT FOR FIT-OUT OF TENANT ON LEVELS 0.0, 0.5, 1.0.

  152. PermitSuppression

    Permit 869798 · COMPLETED

    RELOCATE (228) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  153. PermitSuppression

    Permit 869799 · COMPLETED

    RELOCATE (108) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  154. PermitMechanical

    Permit 859969 · COMPLETED

    FOR INSTALLATION OF A NEW HVAC SYSTEM INCLUDING 31 FAN COIL UNITS, 2 FILTERS POLLUTION CONTROLS UNITS, 2 TEMPERED MAKE UP AIR UNIT 1 POOL DEHUMIDIFIER UNIT, 1 POOL OUTDOOR CONDENSING UNIT, 7 EXHAUST FANS AND ANY ASSOCIATED DUCTWORK AND INSULATION AS PER PLANS.

  155. AppealBuilding standards appeal

    Appeal 33256 · CLOSED · APPROVED

    Related permit 834362 · ON 2/23/18, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #834362

  156. PermitElectrical

    Permit 850995 · COMPLETED

    FIRE ALARM SYSTEM ON FLOORS 5TH-9TH THIS WILL BE TIED INTO THE BLDG'S EXISTING FIRE ALARM SYSTEM AND DEVICE AS PER LOCATION PER NFPA 72(OFFICE SPACE)

  157. PermitSuppression

    Permit 856581 · COMPLETED

    RELOCATE (501) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  158. PermitMajor alteration

    Permit 825994 · COMPLETED

    FOR LEVEL II ALTERATIONS FOR TENANT FITOUT FROM LEVEL 0, LEVEL 0.5, LEVEL 1 AND LEVEL 2. LEVEL 0: PROPOSED PRIVATE CLUB WITH A FITNESS CENTER, LEVEL 0.5: BUSINESSS OCCUPANCY AND FITNESS CENTER, LEVEL 1: BUSINESS OCCUPANCY, AND LEVEL 2.0: BUSINESS OCCUPANCY, HOTEL (14 DWELLING UNITS) AND RESTAURANT. ALTERATIONS TO INCLUDE THE ERECTION OF PARITION WALLS, STRUCTURAL WORK, ACCESSIBILITY IMPROVEMENTS AND FURNISHING/FINISHES THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  159. PermitSuppression

    Permit 848841 · COMPLETED

    RELOCATE (268) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  160. PermitSuppression

    Permit 848842 · COMPLETED

    RELOCATE (315) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  161. AppealBuilding standards appeal

    Appeal 32554 · CLOSED · APPROVED

    Related permit 825994 · ON 01/02/2018, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #825994.

  162. PermitElectrical

    Permit 832365 · COMPLETED

    PROVIDE LABOR AND MATERIAL FOR POWER,LIGHTING,LOW VOLTAGE RACEWAYS AND CABLE TRAY.PROVIDE LABOR AND MATERIAL PANELS AND TRANSFORMER PER 2008 NEC (OFFICE SPACE)

  163. PermitPlumbing

    Permit 835324 · COMPLETED

    FURNISH & INSTALL SOIL VENT & DOMESTIC WATER PIPE TO NEW PLUMBING FIXTURES. FURNISH & INSTALL BREAK ROOMS, LOCKER ROOMS & KITCHEN EQUIPMENTS AS PER PLANS PER PHILADELPHIA 2004 PLUMBING CODE.

  164. PermitZoning/use

    Permit 833696 · COMPLETED

    ZONING FOR NEW INTERIOR FLOOR LEVEL WITH IN AN EXISTING BUILDING. LEVEL 0.5 CREATION OF NEW INTERIOR FLOOR LEVEL TO BE USED AS A FITNESS CENTER AND PRIVATE CLUB. NEW FLOOR LEVEL IS BETWEEN EXISTING FLOOR LEVEL 0 AND FLOOR LEVEL 1.PREVIOUS BULK, MASSING AND USES PERMITTED PER ZONING PERMIT NO. 741708 TO REMAIN EXCEPT AS DESCRIBED IN THIS APPLICATION. ALL PER ATTACHED DRAWINGS.

  165. PermitElectrical

    Permit 833937 · COMPLETED

    FURNISH & INSTALL (5,278) CATEGORY 6A PLENUM CABLES. LONGEST RUN 260'. FURNISH & INSTALL FIBER OPTIC BACKBONE CABLING & COPPER CABLING. ALL INSTALLATIONS IN ACCORDANCE WITH 2008 NEC

  166. PermitMechanical

    Permit 827403 · COMPLETED

    FOR INSTALLATION OF A NEW HVAC SYSTEM INCLUDING MECHANICAL APPLIANCES, REGISTERS, DIFFUSERS AND ASSOCIATED DUCTWORK AS PER PLANS.

  167. PermitSuppression

    Permit 836471 · COMPLETED

    RELOCATE (292) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  168. PermitUse

    Permit 815720 · COMPLETED

    LEVEL 0 - FOR THE CREATION OF FOUR (4) TENANT SPACES FOR USE AS FOLLOWS: SPACE # 2 - BUSINESS AND PROFESSIONAL OFFICE, SPACE # 3 - BUSINESS AND PROFESSIONAL OFFICE, SPACE # 4 - PERSONAL SERVICE (NO ACTIVITIES AS DEFINED IN 14-603 (13) OF PHILADELPHIA ZONING CODE), SPACE # 5 - NIGHT CLUBS AND PRIVATE CLUBS (NO ACTIVITIES AS DEFINED IN 14-603 (13) OF PHILADELPHIA ZONING CODE). LEVEL 1 - FOR THE CREATION OF SIX (6) TENANT SPACES FOR USE AS FOLLOWS: SPACE # 1 - BUSINESS AND PROFESSIONAL OFFICE, SPACE # 2, 4, 5 AND 6 - FOR A SIT DOWN RESTAURANT AND RETAIL SALE OF CONSUMER GOODS, SPACE # 3 - RETAIL SALE OF CONSUMER GOODS. LEVEL 2 - FOR THE CREATION OF FOUR (4) TENANT SPACES FOR USE AS FOLLOWS: SPACE # 1 -VISITOR ACCOMMODATION - FOURTEEN (14) UNITS, SPACE # 2 - SIT DOWN RESTAURANT, SPACE # 3 AND 4 - BUSINESS AND PROFESSIONAL OFFICE WITH ALL OTHER USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT.

  169. PermitMajor alteration

    Permit 815977 · COMPLETED

    INTERIOR ALTERATIONS FOR FIT-OUT TO CREATE AN OFFICE SPACE AS PER APPROVED PLANS. **NO ATRIUM ON THIS PERMIT** **NO STRUCTURAL WORK ON THIS PERMIT FOR ATRIUM** **SEE AP#745717 FOR FIVE STORY ADDITION**

  170. PermitMajor alteration

    Permit 802155 · COMPLETED

    SECOND PHASE EXPANSION (AMENDMENT) OF LEVEL 1 OPEN-AIR PUBLIC SPACE / PROMENADE AT THE WEST SIDE SPANNING FROM MARKET TO CHESTNUT STREETS TO INCLUDE STEEL FRAMING, CONCRETE DECK, RAMPS, STEPS, GUARDS AND ASSOCIATED EXTERIOR FINISH WORK; IMPROVEMENTS ABOVE THE 24TH STREET EXISTING COVERED WALKWAY (RESURFACING) AS APPROVED BY THE STREETS DEPARTMENT. **ALL SPECIAL INSPECTIONS TO TAKE PLACE PER PARENT PERMIT # 745717 AS AN EXTENSION OF THE FIRST PHASE WORK** ***PROTECTION OF PEDESTRIANS, RIGHT-OF-WAY AND ADJACENT STRUCTURES / RAILWAY REQUIRED AT ALL TIMES***

  171. PermitMajor alteration

    Permit 817846 · COMPLETED

    FOUNDATION WORK FOR FITNESS CENTER AT LEVEL 0. NEW INTERIOR PARTIAL FLOOR AT LEVEL 0 FOR FITNESS CENTER, AS PER PLANS.

  172. PermitSuppression

    Permit 766437 · COMPLETED

    COMBINED AUTOMATIC SPRINKLER & WET STANDPIPE SYSTEMS W. TWO (2) EIGHT (8) INCH FIRE SERVICE LINES W. BACKFLOW PREVENTION (BFP) ASSEMBLIES, CONNECTED TO EXISTING CITY MAIN & ASSOCAITED ISOLATION VALVE @ S 24TH ST CITY MAIN, LISTED DIESEL FIRE PUMP ASSEMBLY TO SERVE PREVIOUSLY APPROVED MIXED-USE HIGH RISE BUILDING W. EACH FLOOR SERVED BY SUPERVISED FLOOR CONTROL VALVES PER APPROVED PLANS. AUTOMATIC SPRINKLER, STANDPIPE, & FIRE PUMP ASSEMBLIES INSTALLED PER NFPA 13/14/20.

  173. PermitElectrical

    Permit 780023 · COMPLETED

    RELOCATE DRY COOLERS AND PUMPS FROM ROOF TO GROUND LEVEL PER 2008 NEC (COMMERCIAL)CC DISTRICT

  174. PermitZoning/use

    Permit 785270 · COMPLETED

    FOR THE ERECTION OF FOUR (4) STATICALLY ILLUMINATED, FLAT WALL BUILDING IDENTIFICATION SIGNS ( BOTTOM EDGE OF SIGNS TO BE MIN 150' HIGH AND DO NOT EXTEND ABOVE THE ROOF LINE) FOR USE AS SIGNS ACCESSORY TO EXISTING BUSINESS AND PROFESSIONAL OFFICES IN THE SAME BUILDING WITH OTHER PREVIOUSLY APPROVED USES AND SIGNS.SIZE AND LOCATION AS SHOWN IN APPLICATION.

  175. PermitZoning/use

    Permit 757768 · COMPLETED

    FOR THE ERECTION OF NINE(9) ROOF DECKS; ONE(1) ROOF DECK AT LEVEL FIVE(5), ONE(1) ROOF DECKS AT SIX(6) FLOOR LEVEL, THREE(3) ROOF DECKS AT LEVEL SEVEN(7), THREE(3) ROOF DECKS AT LEVEL NINE(9) AND ONE(1) ROOF DECK AT PH LEVEL AND ERECTION OF PAINTED TRELLIS STRUCTURE ON SOUTHEAST TERRACE OF SEVEN FLOOR LEVEL AND WITH PROPOSED TRELLIS AT PENTHOUSE ROOF DECK AT LEVEL SIX(6) ACCESSORY TO EXISTING COMMERCIAL OFFICES AT LEVEL FIVE(5), SIX(6), SEVEN(7) AND NINE(9) AND IN THE SAME BUILDING WITH AN EXISTING RETAIL COMMERCIAL USE , EATING AND DRINKING ESTABLISHMENT AT FIRST FLOOR ( LEVEL 0 AND LEVEL 1) , BUSINESS AND PROFESSIONAL OFFICES FROM SECOND FLOOR THROUGH NINE(9) FLOORS WITH ALL OTHER PARKING SPACE, LOADING SPACES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION. SIZE AND LOCATION AS SHOWN IN THE APPLICATION.SIZE AND LOCATION AS SHOWN IN THE APPLICATION.

  176. ViolationWORKMANLIKE- PLUMBING CODE

    Case 756093 · Violation 4291629 · Code A-104.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  177. AppealZoning board appeal

    Appeal 30002 · OPEN · Granted with conditions

    Related permit 757768 · PERMIT FOR THE ERECTION OF NINE(9) ROOF DECKS; ONE(1) ROOF DECK AT LEVEL FIVE(5), ONE(1) ROOF DECKS AT SIX(6) FLOOR LEVEL, THREE(3) ROOF DECKS AT LEVEL SEVEN(7), THREE(3) ROOF DECKS AT LEVEL NINE(9) AND ONE(1) ROOF DECK AT PH LEVEL AND

  178. PermitElectrical

    Permit 763124 · COMPLETED

    NEW 13,200 VOLT DUAL SERVICE WITH BACK UP GENERATOR AND COMPLETE ELECTRICAL FIT OUT FOR BASE BUILDING WORK FOR A TEN STORY HIGH RISE MIXED USE BUILDING. INSTALL CAT 6 AND COAX CABLE FOR VOICE DATA TV AND COMPLETE SECURITY SYSTEMS. TEMPORARY SERVICE FOR LIGHTS AND POWER AS PER NEC 2008 COMPLETE FIRE ALARM SYSTEM AS PER NFPA 72 CC DISTRICT

  179. PermitMechanical

    Permit 756322 · COMPLETED

    FOR CORE AND SHELL WORK TO INCLUDE 2-OUTSIDE AIR UNITS, CONDENSING PIPING AND BLC BOXES FOR A VRF HEATING AND A/C SYSTEM FOR THE BUILDING, ONE EXHAUST FAN, 3 STAIRWELL PRESSURIZATION FANS, GAS PIPE FROM EXISTING METER TO ROOF DDAS UNITS AND DUCT AND REFRIGERATION PIPING AS PER PLANS.

  180. PermitPlumbing

    Permit 756093 · COMPLETED

    INTERIOR PLUMBING FOR GANG BATHROOMS ON FLOORS (1) THRU (9) & STORMWATER PIPING TO INCLUDE NEW ROOF DRAINS AND THE ALL NEW "CORE" PIPING FOR THE ERECTION OF A (5)STORY ADDTION TO AN EXISTING MIXED-USE BUILDING CREATE A (10)STORY HI-RISE IN AN EXISTING MIXED-USE BUILDING - "FLAT OFFSETS" OF SANITARY/WASTE STACKS MUST COMPLY WITH SECTION P-1107 OF THE PHILADELPHIA PLUMBING CODE (PPC) 2004 & SECONDARY ROOF DRAINAGE MUST BE PROVIDED TO COMPLY WITH SECTION 1503.4 FOR THE 2009 INTERNATIONAL BUILDING CODE AND SECTION 1107 OF THE 2009 INTERNATIONAL PLUMBING CODE - THE INSTALLATION WILL COMPLY WITH THE PPC 2004

  181. PermitMajor alteration

    Permit 745717 · COMPLETED

    FOR THE ERECTION OF A FIVE-STORY ADDITION TO CREATE A TEN-STORY HIGH-RISE MIXED-USE BUILDING. PERMIT IS ALSO FOR LEVEL III ALTERATIONS TO THE EXISTING STRUCTURE (INTERIOR NON-BEARING PARTITIONS, MILLWORK, FINISHES) AND THE CREATION OF THREE (3) EXIT STAIRWAY CORES, ELEVATOR INSTALLATION, AND LOADING AREAS. BUILDING SHALL BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR TENANT FIT-OUTS, MECHANICAL, ELECTRICAL PLUMBING, AND FIRE SUPPRESSION SYSTEMS. ** ALL ASBESTOS TO BE TREATED & REMOVED PRIOR TO COMMENCEMENT OF WORK. ** FIRE COMMAND CENTER TO BE LOCATED IN APPROVED LOCATION AS PER P.F.D. APPROVAL.

  182. PermitZoning/use

    Permit 741708 · COMPLETED

    APPLICATION FOR ZONING PERMIT. EXISTING CONCRETE 5 STORY STRUCTURE RENOVATECD. PROPOSED ADDTION OF 5 STORY STRUCTURE ABOVE THE RPPF O FTH EEXISTING 5 STORIES WITH A PROGRAM INCLUDING COMMERCIAL SERVICDES, RETAIL SALES, EATING AND DRINKING ESTABLISHMENTS, BUSINESS SUPPORT, LOADING, BUSINESS AND PROFESSIONAL OFFICE.

  183. PermitZoning

    Permit 722651 · COMPLETED

    CONSOLIDATE TWO(2) EXISTING LOTS INTO ONE LOT

  184. License terminal eventBISTRO ST TROPEZ: Food Preparing and Serving business license marked inactive

    License 560602 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  185. PermitElectrical

    Permit 670944 · COMPLETED

    ELECTRICAL SERVICE FROM EXISTING PANELS,INSTALL LIGHTING,REC,SWS, EQUIP CONNECTIONS & BRANCH WIRING,COMMUNICATIONS ALL NEW VOICE AND DATA CABLING AND CONNECTIONS AS PER 2008 NEC (RETAIL) FIRE ALARM ALTERATIONS TO EXISTING FIRE ALARM SYSTEM PER NFPA72.

  186. PermitAddition

    Permit 664342 · COMPLETED

    CONSTRUCTION OF FOUNDATION AND MICRO-PILES TO SUPPORT EXISTING CHESTNUT STREET PLAZA. FOUNDATION WORK AS PER ATTACHED PLANS SIGNED AND SEALED BY A COMMONWEALTH OF PA PROFESSIONAL ENGINEER (PE).

  187. PermitElectrical

    Permit 678589 · COMPLETED

    REPLACING CONDUIT AND CONDUCTORS FOR EXISTING 1500KW/1875KVA STANDBY GENERATOR AS PER 2008 NEC (CC DISTRICT)

  188. PermitElectrical

    Permit 688760 · COMPLETED

    INSTALLATION OF TEMPORARY GENERATOR AS A STANDBY GENERATOR AS PER 2008 NEC. GENERATOR IS TEMPORARY UNTIL REPAIRS ARE MADE TO EXISTING GENERATOR AND WILL BE OPERATED IN THE EVENT OF POWER LOSS. (CC DISTRICT)

  189. PermitMajor alteration

    Permit 668816 · COMPLETED

    EXTERIOR STRUCTURAL AND ARCHITECTURAL ALTERATIONS FOR REMOVAL OF PORTIONS OF EXTERIOR FACADE SYSTEMS, BRICK PANELS, MASONRY, PARAPETS, AND EXTERIOR GLAZING SYSTEMS. INSTALLATIONS OF NEW ARCHITECTURAL FINISHES AND BRICK PANELIZED WALL VENEER SYSTEMS, NEW EXTERIOR GLAZING SYSTEM,TEMPORARY PARAPET ASSEMBLY. ADDITIONAL PERMITS REQ: SIDEWALK SHELTER PLATFORMS ENGINEERED, STREETS DEPARTMENT APPROVALS FOR ANY CLOSURE OR RIGHT OF WAY INSTALLATIONS. BILLBOARD REMOVAL NOT PART OF THIS PERMIT.

  190. InvestigationEP_ELEC

    Case 527427 · PASSED

    The cited inspection visit was marked passed.

  191. ViolationLIC MUST BE AVAIL FOR INSP

    Case 635689 · Violation 4095946 · Code A-302.8/31 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  192. ViolationLISTED CONDIT DOES NOT COMPLY

    Case 635689 · Violation 4095947 · Code A-501.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  193. ViolationNOT CONFORM TO PRC/NEC

    Case 527427 · Violation 3895191 · Code E-1201.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  194. ViolationGROUND-SYSTEM PROPERLY

    Case 527427 · Violation 3895192 · Code E-1201.1/229 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  195. ViolationINSPECT-CONTR MUST ARRANGE

    Case 527427 · Violation 3895193 · Code E-701.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  196. InvestigationEP_ELEC

    Case 527427 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  197. PermitMechanical

    Permit 674197 · COMPLETED

    RELOCATE ONE WATER SOURCE HEAT PUMP. NEW DUCT AND DIFFUSERS FOR 5 HEAT PUMP UNITS. FRESH AIR DUCT INSTALLED TO ALL HEAT PUMPS FROM AN EXISTING OUTSIDE AIR LOUVER. BATHROOM EXHAUST FAN INSTALLED AN DDUCTED TO OUTSIDE AT AN EXISTING LOUVER. ALL NEW DUCT IS IN RETAIL SPACE WITH A PLENUM CEILING

  198. PermitElectrical

    Permit 674818 · COMPLETED

    INSTALL 8 NEW LIGHTING FIXTURES, 12 RECEPTACLES, 2 SWITCHES, HOT WATER CONNECTION FROM EXISTING CIRCUITS AS PER 2008 NEC (CC DISTRICT)

  199. PermitPlumbing

    Permit 674195 · COMPLETED

    FURNISH AND INSTALL 1 POWDER ROOM WC, LAV & ONE MOP SINK. INSTALL HOT WATER HEATER & COPPER WATER SUPPLY PIPING & CAST IRON WASTE PIPING TO FLOOR BELOW. TIE INTO EXISTING WATER & SEWER MAIN INSIDE OF BUILDING (COMMERCIAL)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  200. InvestigationCI INSP

    Case 517529 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  201. PermitSuppression

    Permit 665072 · COMPLETED

    FOR THE EXTENSION OF AN EXISTING FIRE SUPRESSION SYSTEM IN TO A TENANT SPACE IN A BUILDING FOR USE AS A MERCANTILE SPACE. FIRE SUPRESSION SYSTEM TO BE SERVICED BY AN EXISTING FOUR INCH FIRE SERVICE LINE WITH AN EXISTING BACKFLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13.

  202. PermitMajor alteration

    Permit 656982 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A MERCANTILE SPACE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, AND PROVIDE FINISHES THROUGHOUT. SEPARATE PERMIT REQUIRED FOR CERTIFICATE OF OCCUPANCY.ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  203. PermitMajor alteration

    Permit 656975 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A MERCANTILE SPACE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, AND PROVIDE FINISHES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  204. PermitElectrical

    Permit 666598 · COMPLETED

    INSTALLATION OF TEMPORARY GENERATOR AS A STANDBY GENERATOR AS PER 2008 NEC. GENERATOR IS TEMPORARY UNTIL REPAIRS ARE MADE TO EXISTING GENERATOR AND WILL BE OPERATED IN THE EVENT OF POWER LOSS. (CC DISTRICT)

  205. ViolationHAZMAT-LIC REQ¿D

    Case 517529 · Violation 3856742 · Code FC-2701.5/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  206. ViolationHAZMAT-SPILL CLEAN-UP

    Case 517529 · Violation 3856744 · Code FC-2703.3/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  207. ViolationF+C LIQ-PROVIDE CLOS RPT

    Case 517529 · Violation 3856745 · Code FC-3403.3/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  208. ViolationF+C LIQ-LEAKING TANK

    Case 517529 · Violation 3856746 · Code FC-3404.2/8 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  209. ViolationF+C LIQ-AG TNK-PROV OF SHUTOFF

    Case 517529 · Violation 3856747 · Code FC-3404.2/9 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  210. ViolationVIOL C&I MESSAGE

    Case 517529 · Violation 3856741 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  211. ViolationHAZMAT-REM DEF CON+TNK REP/DIS

    Case 517529 · Violation 3856743 · Code FC-2703.2/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  212. InvestigationCI INSP

    Case 517529 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  213. PermitElectrical

    Permit 653476 · COMPLETED

    TENANT FIT OUT INSTALL NEW LIGHTING, RECEPTS SWTICHES, EQUIPMENT CONNECTIONS & BRANCH WIRING AS PER 2008 NEC (CC DISTRICT) AFLTERATIONS TO FIRE ALARM AS PER NFPA72

  214. PermitSuppression

    Permit 663643 · COMPLETED

    RELOCATION OF (28) FIRE SPRINKLER HEADS.

  215. ViolationWORKMANLIKE- BUILDING CODE

    Case 651100 · Violation 3820810 · Code A-104.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  216. PermitPlumbing

    Permit 656580 · COMPLETED

    FURNISH AND INSTALL 1 WATER CLOSET, 1 LAUNDRY, 1 MOP SINK, AND 1 WATER HEATER(ELECTRIC) THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  217. PermitPlumbing

    Permit 653007 · COMPLETED

    INSTALL 2-15" STORM CONNECTIONS, 2-12" SANITARY CONNECTIONS - "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  218. PermitMajor alteration

    Permit 651819 · COMPLETED

    INTERIOR ALTERATIONS, FIT OUT OF NEW STORAGE AREA, BATHROOM, CLOSETS ,DOORS, NEW PARTITIONS, ACCESIBLE UPGRADES, NEW DOOR OPENINGS, ACCESS UPGRADES, IN EXISTING TENANT SPACE 1 LEVEL 0. ADDITIONAL PERMITS REQ: ELECTRIAL, PLUMBING, HVAC, SPRINKLERS.

  219. PermitSuppression

    Permit 655227 · COMPLETED

    RELOCATION OF (55) FIRE SUPPRESSION HEADS.

  220. PermitMechanical

    Permit 651100 · COMPLETED

    NEW DUCTWORK CONNECTED TO EXISTING WSHP'S DUE TO NEW LAYOUT OF THE SPACE AS PER PLANS. (FIVE (5) TON WSHP'S AND ONE 2.5 TON WSHP).

  221. PermitPlumbing

    Permit 651103 · COMPLETED

    AKA 2400 MARKET INTERIOR - MOSS REHAB - LEVEL 1 - INTERIOR PLUMBING ALTERATIONS FOR THE FIT-OUT OF AN OUTPATIENT CARE BUSINESS IN AN EXISTING BUILDING - THE INSTALLATION WILL COMPLY WITH THE APPROVED PLANS AND THE PHILADELPHIA PLUMBING CODE 2004 - NOTE: THE MINIMUM SIZE VENT PERMITTED BY THE PHILADELPHIA PLUMBING CODE 2004 TABLE P-1110.4 IS 1-1/2" PIPE SIZE

  222. PermitMajor alteration

    Permit 643177 · COMPLETED

    LEVEL II ALTERATIONS. FIT-OUT OF OUTPATIENT CARE BUSINESS IN AN EXISTING BUILDING AS PER PLAN.

  223. PermitMajor alteration

    Permit 635282 · COMPLETED

    FOR PARTIAL DEMOLITION OF EXTERIOR NON-LOAD BEARING MASONRY WALLS ONLY, AT GROUND LEVEL AS PER APPROVED PLANS.

  224. PermitAddition

    Permit 635689 · COMPLETED

    FOUNDATION WORK INCLUDING MICRO-PILES FOR FUTURE OVERBUILD ADDITION ABOVE AN EXISTING SIX (6) STORY STRUCTURE AS PER APPROVED PLANS. ALL WORK WITHIN EXISTING BUILDING FOOTPRINT AND ENVELOPE. *SEPARATE PERMITS REQUIRED FOR ERECTION OF ADDITION*

  225. PermitDemolition

    Permit 638536 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.NON BEARING WALL DEMOLITION THROUGHOUT FOUR (4) STORY BUILDING. ALL FIRE RATED WALLS SHALL STAY INTACT, MEANS OF EGRESS SHALL BE MAINTAINE AS WELL AS ALL FIRE SUPPRESSION & PROTECTION SYSTEMS. **POST THIS PERMIT** **POST THE PROJECT INFORMATION SIGN**

  226. PermitMajor alteration

    Permit 629990 · COMPLETED

    SHELTER PLATFORM PERMIT- ERECTION OF A SIDEWALK SHELTER PLATFORM AS PER ENGINEERED PLANS. STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE PRIOR TO THE START OF WORK- THERE WILL BE NO STORAGE ON PLATFORM- SEPERATE PERMITS REQUIRED FOR ANY WORK DONE ON BUILDING.

  227. License terminal eventPATRICE L RAMES (BISTRO ST TROPEZ INC): Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 440683 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  228. License terminal eventXO COMMUNICATIONS SERVICES INC (CHRIS SCHNAITHMAN): Hazardous Materials L&I license filing marked inactive

    License 484509 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  229. PermitZoning/use

    Permit 568154 · COMPLETED

    FOR THE CONDITIONAL APPROVAL OF THE LOT ADJUSTMENT TO CREATE ONE (1) LOT FROM TWO (2) EXISTING LOTS (2402-14 MARKET STREET AND 2330 MARKET STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR THE ERECTION OF AN ADDITION TO THE EXISTING SEMI-DETACHED STRUCTURE WITH ROOF DECKS AT THE 5TH, 7TH, 8TH, 9TH, 11TH, AND 19TH LEVELS. STRUCTURE TO UTILIZE PUBLIC ART, PUBLIC SPACE AND MIXED INCOME HOUSING FLOOR AREA BONUSES. ALL REQUIRED AGREEMENTS AND DOCUMENTATION TO BE SUBMITTED BEFORE FINAL PERMIT ISSUANCE. ENTIRE STRUCTURE TO BE CONSTRUCTED IN COMPLIANCE WITH THE REGULATION OF THE SPECIAL FLOOD HAZARD AREA (§14-704(4)(C)(.2)). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. STRUCTURE FOR USE AS RETAIL SALES OF CONSUMER GOODS ON LEVELS 0-3, WIRELESS SERVICES FACILITY ON LEVEL 0, EATING & DRINKING ESTABLISHMENT (USE REGISTRATION PERMIT REQUIRED TO REGISTER SPECIFIC SUB-CATEGORY) ON LEVEL 1, VISITOR ACCOMMODATIONS ON LEVELS 1, 7-19, MULTI-FAMILY HOUSEHOLD LIVING (TWO-HUNDRED AND EIGHTY FOUR (284) DWELLINGS) ON LEVELS 7-19 (WITH AMENITIES AND ACCESSORY USES ON LEVEL 1), BUSINESS AND PROFESSIONAL OFFICES ON LEVELS 4-6, AND BUILDING SERVICES ON LEVEL 7-19. ALL ROOF DECKS ACCESSORY TO RESIDENTIAL USES. FOR THE CREATION OF NINE (9) NEW OFF-STREET LOADING SPACES (FOR A NEW TOTAL OF ELEVEN (11) LOADING SPACES); FOR THE CREATION OF ONE-HUNDRED AND ONE (101) CLASS 1A BICYCLE PARKING SPACES LOCATED ON AN ACCESSIBLE ROUTE. ALL ACCESSORY CAR PARKING LOCATED AT 12 S 23RD STREET. NO SIGNS ON THIS APPLICATION. FOR THE DOCUMENTATION OF ALL EXISTING PARKING AT 12 S 23RD STREET TO BE CLASSIFIED AS NON-ACCESSORY PER §14-601(8)(K). FOR THE RE-STRIPING OF SPACES TO CREATE ADDITIONAL ACCESSIBLE SPACES. FOR THE ALLOCATION OF THE FOLLOWING PARKING SPACES TO BE USED BY 2402 MARKET STREET: TOTAL OF EIGHTY-FIVE (85) SPACES INCLUDING FIVE (5) ACCESSIBLE SPACES (INCLUDING ONE (1) VAN ACCESSIBLE SPACE). THE REMAINING SEVENTY (70) SPACES INCLUDING FIVE (5) ACCESSIBLE SPACE

  230. License terminal eventPHL HAUSBRANDT CAFE 2 LLC (ACADEMIA DEL CAFFEE): Food Preparing and Serving business license marked inactive

    License 418376 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  231. License issue eventBISTRO ST TROPEZ: Food Preparing and Serving business license initially issued

    License 560602 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  232. PermitMajor alteration

    Permit 309334 · COMPLETED

    SCOPE OF WORK TO INCLUDE MINOR REPAIRS AND PAINTING TO EXISTING PEDESTRIAN BRIDGE AS PER PLANS.

  233. PermitSuppression

    Permit 286693 · COMPLETED

    CONVERT 3 MANUAL DRY STANDPIPES TO 3 AUTOMATIC DRY STANDPIPES, INSTALL PIPE VALVE IN SPRINKLER ROOM AS PER PLAN.

  234. License terminal eventMPDC LP: Dumpster License - Private Property L&I license filing marked inactive

    License 487492 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  235. License issue eventXO COMMUNICATIONS SERVICES INC (CHRIS SCHNAITHMAN): Hazardous Materials L&I license filing initially issued

    License 484509 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  236. InvestigationCI INSP

    Case 81303 · PASSED

    The cited inspection visit was marked passed.

  237. License issue eventMPDC LP: Dumpster License - Private Property L&I license filing initially issued

    License 487492 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  238. InvestigationCI INSP

    Case 81303 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  239. PermitElectrical

    Permit 216722 · COMPLETED

    RTM WILL REMOVE AND REPLACE 26 STRINGS OF 54 VOLT DC BATTERYS, AS PER 2005 NEC (CC DIST)

  240. PermitSuppression

    Permit 207423 · COMPLETED

    IMPROVEMENTS TO AUTOMATIC SPRINKLER SYSTEM.

  241. PermitElectrical

    Permit 205918 · COMPLETED

    (1) DISCONNECT AND REMOVE EXISTING LIGHTING (2) INSTALL (50) NEW FLUORESCENT LIGHTS (3) INSTALL (6) PHONE JACK AND WIRING, ALL AS PER 2005 NEC (CC DIST)

  242. PermitMajor alteration

    Permit 196179 · COMPLETED

    REMOVE DRYWALL CORNERS,CONSTUCT SOFFITS AND DISPLAY WALLS, REMVOE PAINT FORM FLOOR PAINT WALL AND CEILING INSTALL DISPLAYS INSTALL NEW DOOR GLASS

  243. PermitUse

    Permit 201446 · COMPLETED

    USE TO OFFICE AND PRODUCT DISPLAY

  244. PermitSuppression

    Permit 192743 · COMPLETED

    INSTALL AN AUTOMATIC SPRINKLER SYSTEM IN BASEMENT

  245. PermitMajor alteration

    Permit 187632 · COMPLETED

    MINOR DEMO, INTERIOR ALTERATIONS TO INCLUDE DRYWALL PARTITIONS, LIGHTING/POWER, ACOUSTIC CEILINGS, FLOORINGS, SPRINKLER AND HVAC CONSTRUCT NEW STORAGE ROOM, NEW TRAINING ROOM.

  246. PermitUse

    Permit 193300 · COMPLETED

    USING AS A TRAINING FACILITY (LEGALIZING USE)

  247. PermitFast form building

    Permit 190503 · COMPLETED

  248. PermitMechanical

    Permit 188517 · COMPLETED

    ADD 5 SUPPLY DIFFUSERS AND 3 RETURN WITH DUCTWORK.

  249. PermitElectrical

    Permit 185484 · COMPLETED

    BASIC RENOVATIONS TO SHOWROOM: INSTALLING LIGHT FIXTURES, SWITCHES AND RECEPTACLES...IN ACCORDANCE WITH 2005 NEC

  250. PermitMajor alteration

    Permit 182337 · COMPLETED

    PARTIAL INTERIOR ALTERATIONS TO INCLUDE NEW NON-LOADBEARING PARTITIONS, INSTALL NEW DISPLAY, FIXTURES, UPGRADES TO FINISHES FOR EXISTING FURNITURE SHOWROOM, AS PER SUBMITTED PLANS. LO FOR 49 PERSONS. NO CHANGES IN OCCUPANCY OR USE.

  251. PermitSuppression

    Permit 178463 · COMPLETED

    DEMO EXISTING WET SPRINKLER SYSTEM IN TENANT SPACE 407/408. INSTALL NEW PRE-ACTION SPRINKLER SYSTEM TO CONFORM TO TENANT SPACE AS PER NFPA NO 13 AND LOCAL CODES.

  252. License issue eventPATRICE L RAMES (BISTRO ST TROPEZ INC): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 440683 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  253. PermitMechanical

    Permit 112153 · COMPLETED

    INSTALLATION OF NEW 25 TON LIEBERT UNIT WITH MODIFICATION TO DUCTWORK AS SHOWN ON THE APPROVED PLANS.

  254. PermitElectrical

    Permit 92005 · COMPLETED

    INSTALL 57 LIGHT FXTS, 10 RECEPTS, 5 SWS. (CC DIST)

  255. License issue eventPHL HAUSBRANDT CAFE 2 LLC (ACADEMIA DEL CAFFEE): Food Preparing and Serving business license initially issued

    License 418376 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  256. PermitElectrical

    Permit 62837 · COMPLETED

    INSTALLATION OF PLENUM RATED CATEGORY 5E TELEDATA CABLE TO 19 STATION LOCATIONS, 52 DROPS, LONGEST RUN 150 FEET. (CENTER CITY DIST)

  257. PermitElectrical

    Permit 51831 · COMPLETED

    ALL SERVICE OVER CURRENT PROTECTION IS EXIST TO REMAIN. ALL SWS, RECEPTS LIGHTING BEING REPLACED ONE FOR ONE.SPACE WILL HAVE NO ADDTL LOADS.NO F.A.-18 RECESSED DOWN LTS,3 EXIT SIGNS,3 EMERG.WALL PACK,4 PENDANT TRACK LTS W/TRACK PENDANTS,9 GFI RECEPTS,9 DUPL RECEPTS,2 NEW TELE DAT OUTLETS.

  258. PermitPlumbing

    Permit 48493 · COMPLETED

    SUPPLY6 AND INSTALL EJECTOR PIT AND PUMPS IN GROUND, SUPPLY AND INSTALL 10 FIXTURES FOR PHYSICAL THERAPY

  259. PermitElectrical

    Permit 47482 · COMPLETED

    FIRE ALARM, ADD 1 PULL STATION , 2 AV, 2 STROBES, ELECTRICAL INSTALL 61 LIGHTS, 32 SWITCHES, 1 PANEL - 100AMP , 1 PHOTO CELL, 1 TIME CLOCK, 62 RECEPTS, 45' WIRE MOLD, POWER FOR GRINDER, HOT WATER HEATER, CABINET HEATER, 5 HEAT PUMPS

  260. PermitPlumbing

    Permit 47778 · COMPLETED

    INSTALL THE PLUMBING FOR A COFFEE HOUSE, 1 COFFEE MACHINE, 1 ICE MAKER, 1 PREP SINK, 1 DISHWASHER, 1 - 3 COMPARTMENT SINK, 2 HAND SINKS

  261. InvestigationCI INSP

    Case 81303 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 30, 2026, 4:00 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)