Commercial property report
2410-50 E York St
3 stories79,464 sqftICMXbuilt 1925
Jb Ventures 4 LLC
Assessment and City record timeline
The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.
Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $8,009,500. It is not yet the billed-year tax basis.
- OPA assessment · 2016$5.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2017$5.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2018$11M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2019$8.5M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2020$8.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2021$8.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2022$8.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2023$10M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2024$10M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2025$8.0M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2026$8.0M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2027$8.0M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- Permit · 2008-02-19UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2008-05-20DemolitionThis permit category usually covers partial or complete removal work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2008-09-18UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2008-09-22Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Inspection · 2008-09-22BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Permit · 2008-09-29ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2008-09-30SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2008-12-12ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Inspection · 2008-12-12BP_LICENSEA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Permit · 2008-12-17AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2008-12-18PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2008-12-18PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-01-09MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-01-16SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-02-13UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-04-03AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-06-09UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-06-12AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-06-12ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-07-21AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Inspection · 2009-07-21BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Permit · 2009-07-24AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-07-24AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-07-28ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-08-11AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-08-26UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-09-08AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-10-01AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-10-22AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-11-10AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-11-12Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2009-11-12PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2009-12-08AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2010-02-25UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2010-03-11UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2010-03-30UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2010-11-15UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2011-08-29PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2012-01-26Zoning admin reviewThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2012-03-13Zoning admin reviewThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2012-03-19PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2012-04-18Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2012-07-03SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2012-07-03MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Inspection · 2012-07-03PRECOURT (likely: pre-court compliance inspection)A follow-up before or during enforcement escalation; confirm the case sequence in the City file.What Philadelphia inspections check ↗
- Permit · 2013-03-25UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-04-18PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-04-25SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-04-29MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2013-05-21ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-04-28PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-05-06ZoningThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-06-06UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-04-09Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2015-04-15PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-04-17SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-04-22MechanicalThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-05-13ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-05-03UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-05-11UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-07-18Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2018-07-31Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2018-08-08UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-09-27SuppressionThis permit category usually covers fire-suppression systems or related life-safety work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-10-18ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-11-13PlumbingThis permit category usually covers water, drainage, fixtures, or other plumbing work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2018-12-11New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-01-22New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-02-28AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-05-07Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2019-07-08New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-08-15New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-08-27UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2019-11-18Roof Covering ReplacementThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-01-06UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-02-28AdministrativeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-29Signs (Accessory / Non-Accessory)This permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-04-21Interior Non-Load-Bearing Wall Demo.This permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-05-29Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-06-08Change of UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-06-27Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-08-09Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-08-11Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2021-08-20Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-05-06Change of UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-09-18AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-05-09Wall Covering ReplacementThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-10-21Signs (Accessory / Non-Accessory)This permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-11-12SignThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- L&I violation · 2008-10-16CONTRACTOR UNLICENSED SUBA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2008-10-16BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2008-10-16BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2008-09-11CONTRACTOR & BP LIC NEEDEDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2008-09-11BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2008-09-11BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2008-09-23PERMB- REV WK GONE BEYOND ORIGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2008-09-23PERMB REVK- ORD/REG/CON VIOLATA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2008-09-23PERMB- INSTALL FIRE SUPP SYSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2008-09-23PERME- ALTER ELEC INSTALLATIONA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2008-09-23SWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)Stop-work order for construction without a building permitHow L&I violations and orders work ↗
- L&I violation · 2008-09-23SWO- CONTRARY TO GOOD PRACTICEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2008-09-23SWO- CONSTR W/O FIRE PERMITA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2009-04-15PERMB- TO COMPLY VIOLA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2009-04-15PERMF- WK DOES NOT CONFORMA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2009-04-15BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2010-11-24OBTAIN LIC INDICATED (Obtain the license identified in the notice)The shorthand does not identify the license type; open the case notice for that detail.How L&I violations and orders work ↗
- Inspection · 2010-11-24BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- L&I violation · 2010-12-01FIRE/EVAC PLN-REQ'DA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2010-12-01VIOL C&I MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2010-12-01SHELTER PLN-REQ¿DA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2010-12-01CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-10VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- L&I violation · 2011-06-13VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-13VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-13VIOL NONE FOUNDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-13COULD NOT ENTERA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-13COULD NOT ENTERA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2011-06-13CAL LO (Commercial Activity License required)Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city.How L&I violations and orders work ↗
- L&I violation · 2011-06-13COULD NOT ENTERA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2011-06-13BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-13BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-13BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-13BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-13BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-13BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-06-13BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- L&I violation · 2011-11-01CAL LO (Commercial Activity License required)Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city.How L&I violations and orders work ↗
- Inspection · 2011-11-01BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-11-01BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-11-01BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- L&I violation · 2013-04-26PERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)Electrical permit required for wiring installation, replacement, or repairHow L&I violations and orders work ↗
- L&I violation · 2013-04-26PERME- EXTEND SMKE DETECTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2013-04-26BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2014-07-02ANNUAL CERT FIRE SUPPA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2014-07-02ANNUAL CERT FIRE ALARMA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2014-07-02AFES-COMM KITCH SERVICE & CERTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2014-07-02NO ZONING/USE PERMIT-SIGNA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2014-07-02SPECIAL ASSEMBLY OCC LRA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2014-07-02OBTAIN LIC INDICATED (Obtain the license identified in the notice)The shorthand does not identify the license type; open the case notice for that detail.How L&I violations and orders work ↗
- Inspection · 2014-07-02HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- L&I violation · 2017-05-05FIRE SUPPRESSION CERTIFICATIONA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-05-05FIRE ALARM TESTED/CERTIFIEDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-05-05ILLUMINATION EMERGENCY POWERA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-05-05AFES-COMM KITCH SERVICE & CERTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2017-05-05CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2017-06-07TEMPORARY LIGHTINGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07NON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)The title alone does not identify the missing permit or prove the present use remains unauthorized.How L&I violations and orders work ↗
- L&I violation · 2017-06-07SPECIAL ASSEMBLY OCC LRA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07RENEW LIC INDICATEDA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07LO SIGNA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07NON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)The title alone does not identify the missing permit or prove the present use remains unauthorized.How L&I violations and orders work ↗
- L&I violation · 2017-06-07OBTAIN LIC INDICATED (Obtain the license identified in the notice)The shorthand does not identify the license type; open the case notice for that detail.How L&I violations and orders work ↗
- L&I violation · 2017-06-07LO SIGNA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07DRAPERIES/CURTAINSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07SPECIAL ASSEMBLY OCC LOA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07EXIT DOORS SELF CLOSING/LATCHIA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07MEANS OF EGRESS OBSTRUCTIONA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-06-07OPEN JUNCTION BOXESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2017-06-07CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2017-06-07CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2017-06-07CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2017-08-16CO- NEW USE OCCUPIED PRE-COA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-08-16NUISANCE-PREVENTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-08-16OBTAIN LIC INDICATED (Obtain the license identified in the notice)The shorthand does not identify the license type; open the case notice for that detail.How L&I violations and orders work ↗
- L&I violation · 2017-08-16PERM Z- NEW USEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-08-16PERM Z- NEW USEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-08-16OBTAIN LIC INDICATED (Obtain the license identified in the notice)The shorthand does not identify the license type; open the case notice for that detail.How L&I violations and orders work ↗
- L&I violation · 2017-08-16CO- NEW USE OCCUPIED PRE-COA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2017-08-16NUISANCE-PREVENTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2017-08-16CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2017-08-16CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2021-07-20NEW ELECTRICAL WIRINGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2021-07-20L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2006-04-11HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2006-05-02HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2008-10-01BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2008-12-22BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2008-12-22BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2008-12-22BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2009-01-28BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2009-03-18BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2009-05-19BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2009-05-20BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2009-06-11BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2010-12-06CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2010-12-30BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-10-27BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-11-14BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2011-12-22BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2012-01-12BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2012-01-23BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2012-06-27PRECOURT (likely: pre-court compliance inspection)A follow-up before or during enforcement escalation; confirm the case sequence in the City file.What Philadelphia inspections check ↗
- Inspection · 2013-05-10BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2013-05-23BP_BLDGA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2014-09-10HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2015-03-04HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2017-08-01CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2017-08-01CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2017-08-01CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2017-08-02CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2017-08-11CEASE INSP (likely: cease-operations compliance inspection)Legacy inspection shorthand; verify whether a cease-operations order existed and its current status.What Philadelphia inspections check ↗
- Inspection · 2017-08-11CEASE INSP (likely: cease-operations compliance inspection)Legacy inspection shorthand; verify whether a cease-operations order existed and its current status.What Philadelphia inspections check ↗
- Inspection · 2019-04-08CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2019-04-08CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2019-04-08CEASE INSP (likely: cease-operations compliance inspection)Legacy inspection shorthand; verify whether a cease-operations order existed and its current status.What Philadelphia inspections check ↗
- Inspection · 2019-04-08CEASE INSP (likely: cease-operations compliance inspection)Legacy inspection shorthand; verify whether a cease-operations order existed and its current status.What Philadelphia inspections check ↗
- Inspection · 2019-04-10CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2021-10-27L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- License · 2025-06-23Storm the Heavens Fund: Special Permit L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2026-06-22Storm the Heavens Fund: Special Permit L&I license filing marked expiredA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2025-05-13Storm the Heavens Fund: Annual Small Games Of Chance business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2026-07-10Storm the Heavens Fund: Annual Small Games Of Chance business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2020-09-24STARLIGHT STARBRIGHT PLAY & LEARN IN: Food Preparing and Serving (30+ SEATS) business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2020-07-04KARAN SAMAR LLC: Sidewalk Cafe (Temporary) L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2023-03-01KARAN SAMAR LLC: Sidewalk Cafe (Temporary) L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2018-11-07KARAN SAMAR LLC: Food Preparing and Serving (30+ SEATS) business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2016-04-26MUGSHOT 2424 LLC: Food Preparing and Serving (30+ SEATS) business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2019-06-24MUGSHOT 2424 LLC: Food Preparing and Serving (30+ SEATS) business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2015-01-26JB VENTURE 4 LLC: Dumpster License - Private Property L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2014-12-03MUGSHOTS DINER PHILADELPHIA LLC: Food Preparing and Serving (30+ SEATS) business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2014-12-03SKYBOX PRODUCTIONS LLC: Special Assembly Occupancy business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2015-06-29MUGSHOTS DINER PHILADELPHIA LLC: Food Preparing and Serving (30+ SEATS) business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2014-09-112424 EAST YORK PARTNERS LP: Dumpster License - Private Property L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2013-01-24SKYBOX PRODUCTIONS LLC: Special Assembly Occupancy business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- Certification · 2021-08-16Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2022-04-18Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2022-09-27Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-04-19Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-04-19Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-04-22Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-05-01Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-10-31Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-04-15Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-09-04Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-10-17Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2026-04-27Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Appeal · 2009-01-14Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2009-08-19Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2010-02-24Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2010-03-09Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2010-11-10Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2013-01-22Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2013-03-27Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2018-04-25Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
- Appeal · 2019-08-14Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
- LicenseStorm the Heavens Fund: Annual Small Games Of Chance business license marked inactive
- LicenseStorm the Heavens Fund: Special Permit L&I license filing marked expired
- CertificationFire Alarm Certification
- CertificationFire Alarm Certification
- CertificationSprinkler Certification
- LicenseStorm the Heavens Fund: Special Permit L&I license filing initially issued
- LicenseStorm the Heavens Fund: Annual Small Games Of Chance business license initially issued
- CertificationFire Alarm Certification
- PermitSign
- CertificationFire Alarm Certification
- PermitSigns (Accessory / Non-Accessory)
- PermitWall Covering Replacement
- CertificationSprinkler Certification
- CertificationFire Alarm Certification
- PermitAlterations
- CertificationFire Alarm Certification
- CertificationFire Alarm Certification
- LicenseKARAN SAMAR LLC: Sidewalk Cafe (Temporary) L&I license filing marked inactive
- CertificationFire Alarm Certification
- PermitChange of Use
- CertificationFire Alarm Certification
- InspectionL&I investigation
- PermitAddition and/or Alteration
- CertificationFire Alarm Certification
- PermitAddition and/or Alterations
- PermitAddition and/or Alterations
- L&I violationNEW ELECTRICAL WIRING
- InspectionL&I investigation
- PermitAddition and/or Alteration
- PermitChange of Use
- LicenseSTARLIGHT STARBRIGHT PLAY & LEARN IN: Food Preparing and Serving (30+ SEATS) business license initially issued
- LicenseKARAN SAMAR LLC: Sidewalk Cafe (Temporary) L&I license filing initially issued
- PermitAddition and/or Alteration
- PermitInterior Non-Load-Bearing Wall Demo.
- PermitSigns (Accessory / Non-Accessory)
- PermitAdministrative
- PermitUse
- PermitRoof Covering Replacement
- PermitUse
- PermitNew Construction
- AppealZoning board appeal
- PermitNew Construction
- LicenseMUGSHOT 2424 LLC: Food Preparing and Serving (30+ SEATS) business license marked inactive
- PermitMajor alteration
- InspectionCI INSP
- InspectionCI INSP
- InspectionCI INSP
- InspectionCEASE INSP (likely: cease-operations compliance inspection)
- InspectionCEASE INSP (likely: cease-operations compliance inspection)
- PermitAdministrative
- PermitNew Construction
- PermitNew Construction
- PermitPlumbing
- LicenseKARAN SAMAR LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
- PermitElectrical
- PermitSuppression
- PermitUse
- PermitMajor alteration
- PermitMajor alteration
- PermitUse
- PermitUse
- AppealZoning board appeal
- L&I violationCO- NEW USE OCCUPIED PRE-CO
- L&I violationNUISANCE-PREVENT
- L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
- L&I violationPERM Z- NEW USE
- L&I violationPERM Z- NEW USE
- L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
- L&I violationCO- NEW USE OCCUPIED PRE-CO
- L&I violationNUISANCE-PREVENT
- InspectionCI INSP
- InspectionCI INSP
- InspectionCEASE INSP (likely: cease-operations compliance inspection)
- InspectionCEASE INSP (likely: cease-operations compliance inspection)
- InspectionCI INSP
- InspectionCI INSP
- InspectionCI INSP
- InspectionCI INSP
- L&I violationTEMPORARY LIGHTING
- L&I violationNON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)
- L&I violationSPECIAL ASSEMBLY OCC LR
- L&I violationRENEW LIC INDICATED
- L&I violationLO SIGN
- L&I violationNON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)
- L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
- L&I violationLO SIGN
- L&I violationDRAPERIES/CURTAINS
- L&I violationSPECIAL ASSEMBLY OCC LO
- L&I violationEXIT DOORS SELF CLOSING/LATCHI
- L&I violationMEANS OF EGRESS OBSTRUCTION
- L&I violationOPEN JUNCTION BOXES
- InspectionCI INSP
- InspectionCI INSP
- InspectionCI INSP
- L&I violationFIRE SUPPRESSION CERTIFICATION
- L&I violationFIRE ALARM TESTED/CERTIFIED
- L&I violationILLUMINATION EMERGENCY POWER
- L&I violationAFES-COMM KITCH SERVICE & CERT
- InspectionCI INSP
- LicenseMUGSHOT 2424 LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
- LicenseMUGSHOTS DINER PHILADELPHIA LLC: Food Preparing and Serving (30+ SEATS) business license marked inactive
- PermitElectrical
- PermitMechanical
- PermitSuppression
- PermitPlumbing
- PermitMajor alteration
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- LicenseJB VENTURE 4 LLC: Dumpster License - Private Property L&I license filing initially issued
- LicenseMUGSHOTS DINER PHILADELPHIA LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
- LicenseSKYBOX PRODUCTIONS LLC: Special Assembly Occupancy business license marked inactive
- License2424 EAST YORK PARTNERS LP: Dumpster License - Private Property L&I license filing initially issued
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- L&I violationANNUAL CERT FIRE SUPP
- L&I violationANNUAL CERT FIRE ALARM
- L&I violationAFES-COMM KITCH SERVICE & CERT
- L&I violationNO ZONING/USE PERMIT-SIGN
- L&I violationSPECIAL ASSEMBLY OCC LR
- L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- PermitUse
- PermitZoning
- PermitPlumbing
- InspectionBP_BLDG
- PermitElectrical
- InspectionBC INSP (likely: building-code inspection)
- PermitMechanical
- L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
- L&I violationPERME- EXTEND SMKE DETECT
- InspectionBP_BLDG
- PermitSuppression
- PermitPlumbing
- AppealZoning board appeal
- PermitUse
- LicenseSKYBOX PRODUCTIONS LLC: Special Assembly Occupancy business license initially issued
- AppealZoning board appeal
- PermitSuppression
- PermitMechanical
- InspectionPRECOURT (likely: pre-court compliance inspection)
- InspectionPRECOURT (likely: pre-court compliance inspection)
- PermitMajor alteration
- PermitPlumbing
- PermitZoning admin review
- PermitZoning admin review
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- L&I violationCAL LO (Commercial Activity License required)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- PermitPlumbing
- L&I violationVIOL NONE FOUND
- L&I violationVIOL NONE FOUND
- L&I violationVIOL NONE FOUND
- L&I violationCOULD NOT ENTER
- L&I violationCOULD NOT ENTER
- L&I violationCAL LO (Commercial Activity License required)
- L&I violationCOULD NOT ENTER
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- L&I violationVIOL NONE FOUND
- L&I violationVIOL NONE FOUND
- L&I violationVIOL NONE FOUND
- L&I violationVIOL NONE FOUND
- L&I violationVIOL NONE FOUND
- L&I violationVIOL NONE FOUND
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL NONE FOUND
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL NONE FOUND
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL NONE FOUND
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL BC MESSAGE
- L&I violationVIOL BC MESSAGE
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionBC INSP (likely: building-code inspection)
- InspectionCI INSP
- L&I violationFIRE/EVAC PLN-REQ'D
- L&I violationVIOL C&I MESSAGE
- L&I violationSHELTER PLN-REQ¿D
- InspectionCI INSP
- L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
- InspectionBC INSP (likely: building-code inspection)
- PermitUse
- AppealZoning board appeal
- PermitUse
- PermitUse
- AppealZoning board appeal
- PermitUse
- AppealZoning board appeal
- PermitAdministrative
- PermitMajor alteration
- PermitPlumbing
- PermitAdministrative
- PermitAdministrative
- PermitAdministrative
- PermitAdministrative
- PermitUse
- AppealZoning board appeal
- PermitAdministrative
- PermitElectrical
- PermitAdministrative
- PermitAdministrative
- PermitAdministrative
- InspectionBP_BLDG
- PermitAdministrative
- PermitElectrical
- InspectionBP_BLDG
- PermitUse
- InspectionBP_BLDG
- InspectionBP_BLDG
- L&I violationPERMB- TO COMPLY VIOL
- L&I violationPERMF- WK DOES NOT CONFORM
- InspectionBP_BLDG
- PermitAdministrative
- InspectionBP_BLDG
- PermitUse
- InspectionBP_BLDG
- PermitSuppression
- AppealZoning board appeal
- PermitMechanical
- InspectionBC INSP (likely: building-code inspection)
- InspectionBP_BLDG
- InspectionBP_BLDG
- PermitPlumbing
- PermitPlumbing
- PermitAdministrative
- PermitElectrical
- InspectionBP_LICENSE
- L&I violationCONTRACTOR UNLICENSED SUB
- InspectionBC INSP (likely: building-code inspection)
- InspectionBP_BLDG
- InspectionBP_BLDG
- PermitSuppression
- PermitElectrical
- L&I violationPERMB- REV WK GONE BEYOND ORIG
- L&I violationPERMB REVK- ORD/REG/CON VIOLAT
- L&I violationPERMB- INSTALL FIRE SUPP SYS
- L&I violationPERME- ALTER ELEC INSTALLATION
- L&I violationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)
- L&I violationSWO- CONTRARY TO GOOD PRACTICE
- L&I violationSWO- CONSTR W/O FIRE PERMIT
- PermitMajor alteration
- InspectionBP_BLDG
- PermitUse
- L&I violationCONTRACTOR & BP LIC NEEDED
- InspectionBC INSP (likely: building-code inspection)
- InspectionBP_BLDG
- PermitDemolition
- PermitUse
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
Verify the public record
Property tax
$111,725/year estimated property tax
2026 taxable assessment $7,981,500 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.
OPA has published a 2027 assessment of $8,009,500. It is not the 2026 billed-year value.
Payments, credits, interest, and the current amount due are maintained by the City.
OPA 8833767712026 taxable assessment equals the full assessed value.
Historical delinquency sources No current conclusion
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Property report
Commercial property
Offices, recorded in the City's offices category. The public record and owner trail follow.
Recorded owner
Who's behind it
Jb Ventures 4 LLC · corporate / LLC owner
• Tax bills mail to 1550 Latimer St, Philadelphia PA, 19102
Block context
2400 block of E York St. Compare parcels, ownership, and public-record history.
See the whole block →Next door: 2408 E York St · 2406 E York St
L&I license dates · data through Jul 23, 2026
Business licenses at this address Latest pull
What L&I has registered at this OPA parcel, newest initial license date first.
Annual Small Games Of Chance · Initial issue date May 13, 2025 · Terminal license date Jul 10, 2026
Food Preparing and Serving (30+ SEATS) · Initial issue date Sep 24, 2020 · Filed expiration Sep 23, 2026
Food Preparing and Serving (30+ SEATS) · Initial issue date Nov 7, 2018 · Filed expiration Nov 6, 2026
Food Preparing and Serving (30+ SEATS) · Initial issue date Apr 26, 2016 · Terminal license date Jun 24, 2019
Food Preparing and Serving (30+ SEATS) · Initial issue date Dec 3, 2014 · Terminal license date Jun 29, 2015
Special Assembly Occupancy · Initial issue date Jan 24, 2013 · Terminal license date Dec 3, 2014
A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.
Open every source row 279 dated rows
- License terminal eventStorm the Heavens Fund: Annual Small Games Of Chance business license marked inactive
License 0978736 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventStorm the Heavens Fund: Special Permit L&I license filing marked expired
License 0982154 · Expired
License event. Registration does not prove present operation or storefront occupancy.
- CertificationFire Alarm Certification
Certification BC-2026-014618 · Certified
Expires 2027-04-27
- CertificationFire Alarm Certification
Certification BC-2025-029288 · Certified
Expires 2026-10-17
- CertificationSprinkler Certification
Certification BC-2025-025486 · Certified
Expires 2026-09-04
- License issue eventStorm the Heavens Fund: Special Permit L&I license filing initially issued
License 0982154 · Expired
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventStorm the Heavens Fund: Annual Small Games Of Chance business license initially issued
License 0978736 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- CertificationFire Alarm Certification
Certification BC-2025-010899 · Certified
Expires 2026-04-15
- PermitSign
Permit GP-2024-009245 · Expired
FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED PROJECTION SIGN. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLANS. SEPARATE ELECTRICAL PERMITS ARE REQUIRED.
- CertificationFire Alarm Certification
Certification BC-2024-029918 · Certified
Expires 2025-10-31
- PermitSigns (Accessory / Non-Accessory)
Permit ZP-2024-010762 · Issued
FOR THE ERECTION OF ONE STATICALLY ILLUMINATED ACCESSORY PROJECTING SIGN. SIZE AND LOCATION AS SHOWN IN PLANS.
- PermitWall Covering Replacement
Permit GM-2024-003795 · Expired
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.
- CertificationSprinkler Certification
Certification BC-2024-024103 · Certified
Expires 2025-05-01
- CertificationFire Alarm Certification
Certification BC-2024-011496 · Certified
Expires 2025-04-22
- PermitAlterations
Permit PP-2023-013022 · Completed
Replace exterior house drain, curb trap and fresh air inlet per 2018 Philadelphia Plumbing Code.
- CertificationFire Alarm Certification
Certification BC-2023-008725 · Certified
Expires 2024-04-19
- CertificationFire Alarm Certification
Certification BC-2023-008861 · Certified
Expires 2024-04-19
- License terminal eventKARAN SAMAR LLC: Sidewalk Cafe (Temporary) L&I license filing marked inactive
License 845271 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- CertificationFire Alarm Certification
Certification BC-2022-016179 · Certified
Expires 2023-09-27
- PermitChange of Use
Permit ZP-2022-004618 · Issued
Office - Business and Professional
- CertificationFire Alarm Certification
Certification BC-2022-006179 · Certified
Expires 2023-04-18
- InvestigationL&I investigation
Case CF-2021-066584 · PASSED
The cited inspection visit was marked passed.
- PermitAddition and/or Alteration
Permit EP-2021-004649 · Completed
WIRING CUBICLES AND LIGHTING FOR OFFICE SPACES to an existing panel, HVAC to a new sub panel on existing service. AS PER ATTACHED PLANS AS PER 2017 NEC
- CertificationFire Alarm Certification
Certification BC-2021-003195 · Certified
Expires 2022-08-16
- PermitAddition and/or Alterations
Permit FP-2021-002089 · Completed
FOR THE INSTALLATION OF 27 NEW PENDENT SPRINKLERS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE A SIX (6) INCH AMES 2000SS BACK FLOW PREVENTER ASSEMBLY. AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.
- PermitAddition and/or Alterations
Permit MP-2021-004930 · Expired
FOR MECHANICAL ALTERATIONS TO INCLUDE THE INSTALLATION OF CU'S, MINI SPLIT-SYSTEMS, AND EXHASUT FANS, AS PER APPROVED PLANS.
- ViolationNEW ELECTRICAL WIRING
Case CF-2021-066584 · Violation VI-2021-047999 · Code A-301.1/50 · COMPLIED
Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationL&I investigation
Case CF-2021-066584 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitAddition and/or Alteration
Permit CP-2021-001818 · Completed
INTERIOR ALTERATION TO THE ROOM#100 AS PER APPROVED PLAN
- PermitChange of Use
Permit ZP-2021-006333 · Issued
Office - Business and Professional
- License issue eventSTARLIGHT STARBRIGHT PLAY & LEARN IN: Food Preparing and Serving (30+ SEATS) business license initially issued
License 852093 · Active
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventKARAN SAMAR LLC: Sidewalk Cafe (Temporary) L&I license filing initially issued
License 845271 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitAddition and/or Alteration
Permit EP-2020-002378 · Completed
Timer and branch circuit for new exterior wall sign per 2017 NEC.
- PermitInterior Non-Load-Bearing Wall Demo.
Permit GM-2020-000606 · Expired
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.
- PermitSigns (Accessory / Non-Accessory)
Permit ZP-2020-000311 · Issued
- PermitAdministrative
Permit 1044581 · COMPLETED
FOR A CERTIFICATE OF OCCUPANCY OF A PERSONAL SERVICE USE WITHIN AN EXISTING 3-STORY ATTACHED STRUCTURE. NO ALTERATION PROPOSED IN THIS PERMIT. SEPARATE PERMIT REQUIRED FOR ANY INTERIOR FITOUT.
- PermitUse
Permit 1039330 · COMPLETED
FOR A PERSONAL SERVICE AT SPACE# 325 AT THIRD FLOOR IN THE SAME BUILDING WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION.
- PermitRoof Covering Replacement
Permit 1027554 · Expired
EZ PERMIT RE-ROOFING REMOVE DONNAGE/METAL FLU AND ROOFING AND REPLACE ROOF COVERING, RE-INSTALL DONNAGE AS NEEDED. For the Installation of New Roof Coverings on Exiting Roofs as per attached standard. Deviations from these standards require submission of construction and site plans.
- PermitUse
Permit 972647 · COMPLETED
PER ZBA PROVISO - TEMPORARY TO EXPIRE ON 08/01/2024 FOR A TATTOO STUDIO AS PART OF AN EXISTING MULTI-TENANT STRUCTURE WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS PERMIT.
- PermitNew Construction
Permit 1000494 · Expired
ALTERATIONS TO EXISTING NFPA 13 SPRINKLER SYSTEM TO ACCOMODATE NEW TENANT LAYOUT TO INCLUDE DEMOLITION, INSTALLATION AND RELOCATION OF SPRINKLER LINES AND HEADS AS PER APPROVED PLANS.
- AppealZoning board appeal
Appeal 37552 · OPEN · Granted with conditions
Related permit 972647 · PERMIT FOR A TATTOO STUDIO AS PART OF AN EXISTING MULTI-TENANT STRUCTURE WITH ALL OTHER USES AS PREVIOUSLY APPROVED.
- PermitNew Construction
Permit 991411 · Expired
INSTALL (1) MINI SPLIT SYSTEM. (COMMERCIAL)
- License terminal eventMUGSHOT 2424 LLC: Food Preparing and Serving (30+ SEATS) business license marked inactive
License 700253 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitMajor alteration
Permit 947018 · COMPLETED
FOR THE INSTALLATION OF TWO NEW INDOOR WALK IN COOLER 9X18. AND 8X10 IN THE EXPANDED KITCHEN OF EXISITNG RESTAURANT IN SPACE #106. SEE AP#859765 FOR THE ALTERATION WORK.
- InvestigationCI INSP
Case 587798 · PASSED
The cited inspection visit was marked passed.
- InvestigationCI INSP
Case 599731 · PASSED
The cited inspection visit was marked passed.
- InvestigationCI INSP
Case 599738 · PASSED
The cited inspection visit was marked passed.
- InvestigationCEASE INSP (likely: cease-operations compliance inspection)
Case 587757 · PASSED
Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked passed.
- InvestigationCEASE INSP (likely: cease-operations compliance inspection)
Case 587751 · PASSED
Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked passed.
- PermitAdministrative
Permit 941626 · COMPLETED
AMENDMENT TO EXISTING BUILDING PERMIT NO. #859765
- PermitNew Construction
Permit 943113 · Issued
INSTALL APPROX 10 NEW LIGHTS WITH 2 NEW ENERGY LIGHTS IN NEW HALLWAY FROM EXISTING LIGHTING CIRCUIT, PER 2008 NEC
- PermitNew Construction
Permit 932236 · Expired
EXTENSION OF AN EXISTING NFPA 13 SPRINKLER SYSTEM TO PROTECT NEW FIRST FLOOR CORRIDORS AS PER APPROVED PLANS. NO WORK TO EXISTING SPRINKLER RISER. WORK TO BE PERFORMED BY A PHILADELPHIA LICENSED FIRE SUPPRESSION CONTRACTOR.
- PermitPlumbing
Permit 917976 · COMPLETED
NEW DRAINS & WATER LINES FOR BATHROOM, NEW SHOWER, NEW SINK & NEW ADA TOILET THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004
- License issue eventKARAN SAMAR LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
License 793942 · Active
License event. Registration does not prove present operation or storefront occupancy.
- PermitElectrical
Permit 906232 · COMPLETED
USING EXISTING HOUSE PANEL, LIGHTING, SWITCHES, RECEPTACLES, EMERGENCY LIGHTS, CATV & PHONE AND RELOCATE EXISTING FIRE ALARM DEVICES AS REQUIRED WITH NO ADDITIONAL WIRING AS PER NEC 2008 EAST DISTRICT
- PermitSuppression
Permit 909583 · COMPLETED
FOR THE EXTENSION OF AN EXISTING NFPA 13 SYSTEM SERVICED BY AN EXISTING 6 INCH FIRE SERVICE LINE WITH AN EXISTING BACKFLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13 STANDARD.
- PermitUse
Permit 900588 · COMPLETED
PERMIT FOR RELIGIOUS ASSEMBLY IN SPACE #100 AS PART OF AN EXISTING MULTI-TENANT STRUCTURE WITH OTHER USES AS PREVIOUSLY APPROVED.NO SIGNS ON THIS APPLICATION
- PermitMajor alteration
Permit 885023 · COMPLETED
LEVEL 2 ALTERATIONS TO A TENANT SPACE FOR USE AS A ROCK CLIMBING HEALTH CLUB TO INCLUDE NEW FLOORING, NEW PARTITIONS, NEW HANDICAP ACCESSIBLE SHOWER ROOM AND RECONFIGURE TOILET FIXTURES AS PER PLANS.
- PermitMajor alteration
Permit 859765 · COMPLETED
FOR INTERIOR LEVEL 2 ALTERATIONS TO CREATE NEW CORRIDORS ANF AN OPEN OFFICE SPACE AS PER PLANS.
- PermitUse
Permit 876353 · COMPLETED
USE AS BUSINESS AND PROFESSIONAL ON THE FIRST FLOOR OF AN EXISTING STRUCTURE ( IN UNIT # 106-A) WITH ALL OTHER USES AS PREVIOUSLY APPROVED. (NO SIGN ON THIS PERMIT)
- PermitUse
Permit 873385 · COMPLETED
USE FOR ROCK CLIMBING HEALTH CLUB (PERSONAL SERVICE)ON THE 1ST FLOOR OF THE EXISTING BUILDING WITH OTHER PREVIOUSLY APPROVED USE.THE LOCATION WITHIN THE EXISTING BUILDING IS SHOW ON THE ATTACHED FLOOR PLAN. THERE ARE NO SIGNS ASSOCIATED WITH THIS APPLICATION
- AppealZoning board appeal
Appeal 32049 · CLOSED · Denied
Related permit 859061 · PERMIT FOR A BANQUET HALL FOR MAXIMUM FOUR HUNDRED (400) PEOPLE (NIGHT CLUBS AND PRIVATE CLUBS) (NO ACTIVITIES AS DEFINED IN SECTION 14-601 (7) OF PHILADELPHIA ZONING CODE) IN UNIT # 106-A AS PART OF AN EXISTING MULTI-TENANT STRUCTURE WITH
- ViolationCO- NEW USE OCCUPIED PRE-CO
Case 599731 · Violation 4422824 · Code A-701.1/3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationNUISANCE-PREVENT
Case 599731 · Violation 4422822 · Code 19-2602.4/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
Case 599731 · Violation 4422825 · Code LO-1 · COMPLIED
The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationPERM Z- NEW USE
Case 599731 · Violation 4422823 · Code A-301.1/65 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationPERM Z- NEW USE
Case 599738 · Violation 4422885 · Code A-301.1/65 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
Case 599738 · Violation 4422887 · Code LO-1 · COMPLIED
The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationCO- NEW USE OCCUPIED PRE-CO
Case 599738 · Violation 4422886 · Code A-701.1/3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationNUISANCE-PREVENT
Case 599738 · Violation 4422884 · Code 19-2602.4/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationCI INSP
Case 599738 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 599731 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCEASE INSP (likely: cease-operations compliance inspection)
Case 587751 · FAILED
Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCEASE INSP (likely: cease-operations compliance inspection)
Case 587757 · FAILED
Legacy inspection shorthand; verify whether a cease-operations order existed and its current status. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 582647 · PASSED
The cited inspection visit was marked passed.
- InvestigationCI INSP
Case 587751 · CLOSED
City marked the record closed; open the case for the closing reason.
- InvestigationCI INSP
Case 587757 · CLOSED
City marked the record closed; open the case for the closing reason.
- InvestigationCI INSP
Case 587798 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationTEMPORARY LIGHTING
Case 587751 · Violation 4417661 · Code FC-13-605.9 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationNON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)
Case 587751 · Violation 4417659 · Code 14-1704/10 · COMPLIED
The title alone does not identify the missing permit or prove the present use remains unauthorized. City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSPECIAL ASSEMBLY OCC LR
Case 587751 · Violation 4417658 · Code 09-703.1/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationRENEW LIC INDICATED
Case 587751 · Violation 4417662 · Code LR-1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationLO SIGN
Case 587751 · Violation 4417660 · Code FC-13-1004.2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationNON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)
Case 587757 · Violation 4417689 · Code 14-1704/10 · COMPLIED
The title alone does not identify the missing permit or prove the present use remains unauthorized. City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
Case 587757 · Violation 4417692 · Code LO-1 · COMPLIED
The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationLO SIGN
Case 587757 · Violation 4417690 · Code FC-13-1004.2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationDRAPERIES/CURTAINS
Case 587757 · Violation 4417691 · Code FC-13-807.1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSPECIAL ASSEMBLY OCC LO
Case 587757 · Violation 4417688 · Code 09-703.1/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationEXIT DOORS SELF CLOSING/LATCHI
Case 587798 · Violation 4406303 · Code FC-13-100825 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationMEANS OF EGRESS OBSTRUCTION
Case 587798 · Violation 4406302 · Code FC-13-1003.3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationOPEN JUNCTION BOXES
Case 587798 · Violation 4406304 · Code FC-13-605.6 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationCI INSP
Case 587798 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 587751 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 587757 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationFIRE SUPPRESSION CERTIFICATION
Case 582647 · Violation 4306005 · Code FC-13-915.1A · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationFIRE ALARM TESTED/CERTIFIED
Case 582647 · Violation 4306004 · Code FC-13-915.1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationILLUMINATION EMERGENCY POWER
Case 582647 · Violation 4306003 · Code FC-13-1006.3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationAFES-COMM KITCH SERVICE & CERT
Case 582647 · Violation 4306006 · Code FC-904.11/4 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationCI INSP
Case 582647 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- License issue eventMUGSHOT 2424 LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
License 700253 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventMUGSHOTS DINER PHILADELPHIA LLC: Food Preparing and Serving (30+ SEATS) business license marked inactive
License 648359 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitElectrical
Permit 601635 · COMPLETED
WIRING AND INSTALLATION OF 14 RECETACLES,13 LIGHT FIXTUES SUPPPLIED AND 1 EXIT SIGN PER (MEDICAL OFFICE)INSTALLATION TO COMPLY WITH ARTICLE 517.13 OF THE 2008 NEC.
- PermitMechanical
Permit 604695 · COMPLETED
DUCTWORK MODIFICATIONS TO EXISTING, ADDING 4 SUPPLY VENTS(COMMERCIAL)
- PermitSuppression
Permit 603740 · COMPLETED
RELOCATE 15 SPRINKLER HEADS
- PermitPlumbing
Permit 602881 · COMPLETED
NEW DRAINS AND WATER LINES TO 3 NEW SINKS AND 2" STACK AND VENT (COMMERCIAL)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004
- PermitMajor alteration
Permit 595250 · COMPLETED
INTERIOR ALTERATIONS FOR THE EXPANSION OF EXISTING TENANT SPACE INTO ADJACENT SPACE
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 441200 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
- License issue eventJB VENTURE 4 LLC: Dumpster License - Private Property L&I license filing initially issued
License 653273 · Active
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventMUGSHOTS DINER PHILADELPHIA LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
License 648359 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventSKYBOX PRODUCTIONS LLC: Special Assembly Occupancy business license marked inactive
License 493120 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue event2424 EAST YORK PARTNERS LP: Dumpster License - Private Property L&I license filing initially issued
License 641224 · Active
License event. Registration does not prove present operation or storefront occupancy.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 441200 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationANNUAL CERT FIRE SUPP
Case 441200 · Violation 3325086 · Code FC-915.1/4 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationANNUAL CERT FIRE ALARM
Case 441200 · Violation 3325085 · Code FC-915.1/3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationAFES-COMM KITCH SERVICE & CERT
Case 441200 · Violation 3325084 · Code FC-904.11/4 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationNO ZONING/USE PERMIT-SIGN
Case 441200 · Violation 3325083 · Code 14-1704/50 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSPECIAL ASSEMBLY OCC LR
Case 441200 · Violation 3325082 · Code 09-703.1/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
Case 441200 · Violation 3325087 · Code LO-1 · COMPLIED
The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 441200 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitUse
Permit 442351 · COMPLETED
FOR A TATTO PALOR
- PermitZoning
Permit 529105 · COMPLETED
FOR THE RELOCATION OF LOT LINES TO CREATE TWO (2) NEW LOTS FROM ONE (1) EXISTING LOT. SIZE AND LOCATION AS SHOWN ON APPLICATION.
- PermitPlumbing
Permit 533221 · COMPLETED
REPLACE 2 CURB TRAPS, 4" MAIN DRAINS AND FRONT RAINLEADERS - PA1 CALL# 2014-1132469
- InvestigationBP_BLDG
Case 377789 · PASSED
The cited inspection visit was marked passed.
- PermitElectrical
Permit 468278 · COMPLETED
INSTALL 2-200 AMP PANELS FOR 600 AMP MDP(SUB PANELS);INSTALL LIGHTING,RECEPTS,HOOD SYSTEM ETC AS PER 2008 NEC. (F/A INSTALLED 2 HORN/STROBES AND 1 PULL STATION INSTALLED BY OTHERS) AS PER 2008 NEC AND NFPA72 (DINER)
- InvestigationBC INSP (likely: building-code inspection)
Case 281953 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- PermitMechanical
Permit 465231 · COMPLETED
INSTALLATION OF (5) HVAC SYSTEMS THEY ARE 5 TON, 2,000 CFM EACH WITH DUCTWORK - RESTAURANT
- ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
Case 377789 · Violation 2775556 · Code A-301.1/51 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationPERME- EXTEND SMKE DETECT
Case 377789 · Violation 2775555 · Code A-301.1/32 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBP_BLDG
Case 377789 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitSuppression
Permit 467494 · COMPLETED
RELOCATE 12 SPRINKLERS TO NEW CEILING LAYOUT
- PermitPlumbing
Permit 465986 · COMPLETED
1-COMP SINK, 1 DISHWASHER, 1 BAR SINK, 2 WC 2 LAV SINK 1 MOP SINK 5 HAND SINK
- AppealZoning board appeal
Appeal 19840 · CLOSED · Granted with conditions
Related permit 442351 · PERMIT FOR BODY ART SERVICES IN SPACE #324 AS PART OF AN EXISTING MULTI-TENANT STRUCTURE WITH OTHER USES AS PREVIOUSLY APPROVED.
- PermitUse
Permit 430677 · COMPLETED
CONTINUATION OF PREVIUOSLY APPROVED 3 YEAR TEMPORARY USE AS HOUSE OF WORSHIP IN SPACE #122 IN THE SAME BUILDING WITH OTHER USES AS PREVIOUSLY APPROVED. NO NEW SIGNS ON THIS APPLICATION.
- License issue eventSKYBOX PRODUCTIONS LLC: Special Assembly Occupancy business license initially issued
License 493120 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- AppealZoning board appeal
Appeal 19235 · CLOSED · Granted
Related permit 430677 · PERMIT FOR RELIGIOUS ASSEMBLY IN SPACE #122 AS PART OF AN EXISTING MULTI-TENANT STRUCTURE WITH OTHER USES AS PREVIOUSLY APPROVED.
- PermitSuppression
Permit 413462 · COMPLETED
INSTALL TWO ANSUL FIRE SUPPRESSION SYSTEMS FOR 2 HOODS.
- PermitMechanical
Permit 413464 · COMPLETED
INSTALL TYPE 1 HOODS, 24'0" HOOD AND 15'-0 HOOD WITH STAINLESS STEEL DUCT WORK AND FANS, IN CONJUNCTION WITH AP413462 & 378330
- InvestigationPRECOURT (likely: pre-court compliance inspection)
Case 304551 · PASSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.
- InvestigationPRECOURT (likely: pre-court compliance inspection)
Case 281954 · PASSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.
- PermitMajor alteration
Permit 378330 · COMPLETED
INTERIOR ALTERATIONS FOR A RESTAURANT TO INCLUDE DEMOLITION OF EXISTING PARTITION WALLS & CONSTRUCTION OF COMMERCIAL KITCHEN AREA, DINING AREA WITH FIXED SEATING, & ACCESSIBLE TOILET ROOMS. EXTERIOR CONSTRUCTION FOR THE INSTALLATION OF A NEW ACCESSIBLE RAMP & ENTRANCE INTO RESTAURANT SPACE. ***SEPARATE MECHANICAL, PLUMBING, ELECTRICAL, & FIRE SUPPRESSION PERMITS REQUIRED PRIOR TO OCCUPANCY.***
- PermitPlumbing
Permit 394147 · COMPLETED
INSTALL 3 HAND SINKS, 6 FLOOR SINKS, 1 KS, 2 TOILETS, 2 LAVS, FLOOR DRAINS AND MAIN DRAIN(COMMERCIAL)
- PermitZoning admin review
Permit 385868 · COMPLETED
ADMIN REVIEW OF ZBA CAL NO 7601 (01-14-09) TO DOCUMENT/CONFIRM LOCATION OF RESTAURANT ON THE 1ST FLOOR.
- PermitZoning admin review
Permit 385181 · COMPLETED
ART/GALLERY SPACES, INCLUDING THE ACCESSORY SALES OF ARTWORK, PROFESSIONAL OFFICES, AND RESTAURANT/CAFE WITH ACCESSORY STORAGE SPACE(INCIDENTAL TAKE OUT)
- InvestigationBC INSP (likely: building-code inspection)
Case 304551 · CLOSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.
- InvestigationBC INSP (likely: building-code inspection)
Case 281954 · CLOSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.
- InvestigationBC INSP (likely: building-code inspection)
Case 304551 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBC INSP (likely: building-code inspection)
Case 281954 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationCAL LO (Commercial Activity License required)
Case 304551 · Violation 2340985 · Code 19-2602.1/1 · COMPLIED
Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city. City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBC INSP (likely: building-code inspection)
Case 281946 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281961 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 304551 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBC INSP (likely: building-code inspection)
Case 259896 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- PermitPlumbing
Permit 360636 · COMPLETED
HOUSE TRAP,HOUSE DRAIN
- ViolationVIOL NONE FOUND
Case 281815 · Violation 2107201 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281821 · Violation 2107209 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281825 · Violation 2107224 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationCOULD NOT ENTER
Case 281946 · Violation 2108166 · Code A.CNE.000 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationCOULD NOT ENTER
Case 281953 · Violation 2108195 · Code A.CNE.000 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationCAL LO (Commercial Activity License required)
Case 281954 · Violation 2332767 · Code 19-2602.1/1 · COMPLIED
Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city. City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationCOULD NOT ENTER
Case 281961 · Violation 2108271 · Code A.CNE.000 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBC INSP (likely: building-code inspection)
Case 281961 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBC INSP (likely: building-code inspection)
Case 281815 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281821 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281825 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281946 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBC INSP (likely: building-code inspection)
Case 281953 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBC INSP (likely: building-code inspection)
Case 281954 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationVIOL NONE FOUND
Case 281661 · Violation 2105961 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281666 · Violation 2105992 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281670 · Violation 2106050 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281675 · Violation 2106086 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281680 · Violation 2106119 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281682 · Violation 2106134 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281684 · Violation 2106147 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281685 · Violation 2106154 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281686 · Violation 2106153 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281690 · Violation 2106170 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281691 · Violation 2106168 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL NONE FOUND
Case 281692 · Violation 2106184 · Code A-000.0/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281697 · Violation 2106230 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281699 · Violation 2106245 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281701 · Violation 2106246 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281703 · Violation 2106257 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281705 · Violation 2106261 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL BC MESSAGE
Case 281709 · Violation 2106267 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBC INSP (likely: building-code inspection)
Case 281670 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281709 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281705 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281703 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281701 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281699 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281697 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281692 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281691 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281690 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281686 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281685 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281684 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281682 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281680 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281675 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281666 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 281661 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationBC INSP (likely: building-code inspection)
Case 259896 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 260454 · PASSED
The cited inspection visit was marked passed.
- ViolationFIRE/EVAC PLN-REQ'D
Case 260454 · Violation 1906997 · Code FC-404.2/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationVIOL C&I MESSAGE
Case 260454 · Violation 1906995 · Code A-000.0/10 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSHELTER PLN-REQ¿D
Case 260454 · Violation 1906996 · Code FC-409.1/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationCI INSP
Case 260454 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
Case 259896 · Violation 1939809 · Code LO-1 · COMPLIED
The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBC INSP (likely: building-code inspection)
Case 259896 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitUse
Permit 298378 · COMPLETED
DISPLAY AND SALE OF HANDMADE MACHINE MADE WIGS, BEAUTY SUPPLIES AND STYLING AIDS FOR PERSONS WITH MEICAL HAIR LOSS AND HAIR RESTORATION BEAUTY SALON IN UNIT 224
- AppealZoning board appeal
Appeal 13443 · CLOSED · Granted
Related permit 298378 · PERMIT FOR A HAIR / BEAUTY SALON TO INCLUDE MEDICAL HAIR LOSS SERVICES, RETAIL SALES OF WIGS, HAIR LOSS PRODUCTS AND STYLING AIDS (NO MEDICAL TREATMENT OF PATIENTS, NO ACTIVITY AS DEFINED IN SECTION 14-1605) IN UNIT # 224 ON THE SECOND FLO
- PermitUse
Permit 269512 · COMPLETED
REGISTER USE AS MEDICAL OFFICE PROVIDING PHYSICAL THERAPY TREATMENT AND GENERAL EXERCISE / WELLNESS PROGRAM
- PermitUse
Permit 256773 · COMPLETED
INTERIOR ALTERIONS TO ADD CHURCH/HOUSE OF WORSHIP USE IN TENANT SPACE 122
- AppealZoning board appeal
Appeal 10929 · CLOSED · Granted with conditions
Related permit 256773 · PERMIT FOR A HOUSE OF WORSHIP IN SPACE #122 IN THE SAME BUILDING WITH OTHER USES AS PREVIOUSLY APPROVED.
- PermitUse
Permit 254628 · COMPLETED
ADDING TATTOO PARLOR AND ART GALLERY/EXIBITION SPACE IN TENANT SPACE 239
- AppealZoning board appeal
Appeal 10791 · CLOSED · Granted with conditions
Related permit 254628 · PERMIT FOR THE TATTOO PARLOR AND ART GALLERY IN TENANT SPACE # 239 AS PART OF AN EXISTING ART GALLERY AND EXHIBITION SPACE INCLUDING THE ACCESSORY SALE OF ARTWORK, PROFESSIONAL OFFICES (INCLUDING MEDICAL OFFICES FOR THE TREATMENT OF PATIENT
- PermitAdministrative
Permit 237119 · COMPLETED
AMEND PERMIT #209360. SEPARATE CO PERMIT REQUIRED FOR EACH TENANT SPACE.
- PermitMajor alteration
Permit 238269 · COMPLETED
ALTERATIONS TO VACANT SPACE TO CREATE A DAYCARE CENTER ON 1ST FLOOR. BUILDING TO BE FULLY SPRINKLERED. CO REQ. USE PERMIT # 212934.
- PermitPlumbing
Permit 247719 · COMPLETED
INSTALL 5 LAV'S AND 5 WATER CLOSETS
- PermitAdministrative
Permit 245514 · COMPLETED
TCO FOR OFFICE UNITS AS DESCRIBED. START DATE FOR TCO DOCUMENT IS 10/7/09.
- PermitAdministrative
Permit 244032 · COMPLETED
RENEWAL OF TCO FOR ARTIST STUDIO FOR UNITS 107, 108, 109, 110, 111, 112, 113, 114 AND 115. START DATE FOR THIS TCO IS 9/10/09. PREVIOUS EXAMINER KEVIN HEENAN FOR PERMIT # 167225
- PermitAdministrative
Permit 239742 · COMPLETED
LO SIGNAGE FOR ASSEMBLY ART GALLERY, AND 1ST, 2ND, 3RD FLOORS, ADDITIONAL AMENDMENTS AS PER SUBMITTED PLANS. MIXED OCCUPANCY NON SEPARATED USES. DAYCARE AREA OCCUPANCY NOT APPROVED UNDER AP238269. PRIOR APPROVAL FOR EVENT ROOM GALLERY OCCUPANCY UNDER TCO AP205983, REVISED TYPE OF CONSTRUCTION 209360. FURTHER REVISIONS AP237119 PENDING.
- PermitAdministrative
Permit 235803 · COMPLETED
TCO FOR OFFICE UNITS AS DESCRIBED.
- PermitUse
Permit 212934 · COMPLETED
DAY CARE CENTER W/ MAXIMUM OF 60 CHILDREN (NO CHILDREN UNDER 2.5 YRS. OLD) & ACC. PREP & SERVE OF FOOD (1ST FLOOR)
- AppealZoning board appeal
Appeal 9098 · CLOSED · Granted
Related permit 212934 · PERMIT FOR A DAYCARE FACILITY FLOORS 1 & 2, FOR A MAXIMUM OF SIXTY(60) CHILDREN TO INCLUDE NO CHILDREN UNDER THE AGE OF 2 1/2 YEARS OF AGE, ACCESSORY PREPARING AND SERVING OF FOOD, FOR PERIODS LESS THAN TWENTY-FOUR(24) HOURS. NO SIGNS ON TH
- PermitAdministrative
Permit 231297 · COMPLETED
TCO FOR UNIT #213
- PermitElectrical
Permit 225899 · COMPLETED
NEW 1000 KVA TRANFORMER 120/208 USING EXISTING 15 KV SER/ SWITCH.NEW SECONDARY SWITCHBRD,(4) 1200A FEEDERS TO (3) METERING CENTERS/(1) 1200A HOUSE PANEL,NEW GROUNDING ELECTRODE/GROUND RODS,ALL OTHER BLDG WORK BY OTHER CONTR'S UNDER DIFFERENT PERMITS, ALL AS PER 2005 NEC (EAST DIST)
- PermitAdministrative
Permit 228433 · COMPLETED
EXTENSION OF EXPIRED TCO PERMITS #205983 [SKYBOX] AND #191338 [UNITS 116, 117, 118, 119, & 121]
- PermitAdministrative
Permit 228464 · COMPLETED
TCO FOR UNITS #211, 212, & 221 [START DATE OF JULY 20, 2009]
- PermitAdministrative
Permit 215861 · COMPLETED
TCO FOR ARTIST STUDIO FOR UNITS 107, 108, 109, 110, 111, 112, 113, 114 AND 115. PREVIOUS EXAMINER KEVIN HEENAN FOR PERMIT # 167225
- InvestigationBP_BLDG
Case 196261 · PASSED
The cited inspection visit was marked passed.
- PermitAdministrative
Permit 209360 · COMPLETED
AMEND BLDG. PERMIT # 167225 TO INCORPORATE CHANGES MADE
- PermitElectrical
Permit 208119 · COMPLETED
FIRE ALARM SYSTEM AS PER NFPA-72 (NORTH DIST)
- InvestigationBP_BLDG
Case 179594 · PASSED
The cited inspection visit was marked passed.
- PermitUse
Permit 219609 · COMPLETED
ADDING PREP AND DISTRIBUTION OF FOODSTUFFS FOR OFF-PREMISES CATERING TO EXISTING USES; CREATION OF ONE TENANT SPACE (SPACE A) FROM SEVEN SPACES
- InvestigationBP_BLDG
Case 196261 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBP_BLDG
Case 179594 · PASSED
The cited inspection visit was marked passed.
- ViolationPERMB- TO COMPLY VIOL
Case 196261 · Violation 1337935 · Code A-301.6/1 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationPERMF- WK DOES NOT CONFORM
Case 196261 · Violation 1337936 · Code A-302.10/32 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBP_BLDG
Case 196261 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitAdministrative
Permit 205983 · COMPLETED
TCO APPLICATION FOR MULTI PURPOSE ROOM "COMMON AREA"
- InvestigationBP_BLDG
Case 179594 · PASSED
The cited inspection visit was marked passed.
- PermitUse
Permit 181053 · COMPLETED
ART/GALLERY SPACES, INCLUDING THE ACCESSORY SALES OF ARTWORK, PROFESSIONAL OFFICES, AND RESTAURANT/CAFE WITH ACCESSORY STORAGE SPACE(INCIDENTAL TAKE OUT)
- InvestigationBP_BLDG
Case 179594 · PASSED
The cited inspection visit was marked passed.
- PermitSuppression
Permit 188323 · COMPLETED
REMOVE ALL 3/4" BRANCH LINES AND REPLACE WITH 1" PIPE. REMOVE AND REPLACE ALL FIRE SPRINKLER, HEADS, THROUGHOUT.
- AppealZoning board appeal
Appeal 7601 · OPEN · Granted with conditions
Related permit 181053 · PERMIT FOR ART GALLERIES WITH EXHIBITION SPACES, INCLUDING ACCESSORY SALE OF ART WORK, PROFESSIONAL OFFICES INCLUDING MEDICAL OFFICES INCLUDING TREATMENT OF PATIENTS, RESTAURANT WITH ACCESSORY STORAGE (NOT TO EXCEED 25% GFA) ACCESSORY OFFIC
- PermitMechanical
Permit 195150 · COMPLETED
INSTALL A/C AND HEAT UNIT. 6-10 TON ROOF TOP UNIT . 7-5 TON SPLIT SYSTEM. EXHAUST FAN AS PER PLANS.
- InvestigationBP_BLDG
Case 178164 · PASSED
The cited inspection visit was marked passed.
- InvestigationBP_BLDG
Case 178166 · PASSED
The cited inspection visit was marked passed.
- PermitPlumbing
Permit 193638 · COMPLETED
FIXTURE REPLACEMENT
- PermitPlumbing
Permit 193642 · COMPLETED
REPLACE STACK AND FIXTURES
- PermitAdministrative
Permit 191338 · COMPLETED
TCO FOR OFFICES 116-119 AND 121
- PermitElectrical
Permit 191910 · COMPLETED
RENOVATION OF EXISTING BUILDING ELECTRIC TO ACCOMMODATE 97 STUDIOS/OFFICES, TO INCLUDE A 100 AMP SERVICE PER UNIT, 7 ROOF TOP PACKAGED HEAT PUMPS WITH 60AMP/3 PHASE PER UNIT, 1 HOUSE METER AT 800 AMPS AS PER 2005 NEC (EAST DIST)
- InvestigationBP_LICENSE
Case 178164 · PASSED
The cited inspection visit was marked passed.
- ViolationCONTRACTOR UNLICENSED SUB
Case 178164 · Violation 1193614 · Code 9-1004.2/3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBC INSP (likely: building-code inspection)
Case 178164 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBP_BLDG
Case 178166 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBP_BLDG
Case 179594 · PASSED
The cited inspection visit was marked passed.
- PermitSuppression
Permit 179993 · COMPLETED
RELOCATE 20 SPRINKLER HEADS - SEE HANSEN CASE 179594
- PermitElectrical
Permit 179599 · COMPLETED
SELECT DEMO OF EXISTING ELEC TO ALLOW INTERIOR DEMO. INSTALLATION OF TEMP LTG SIX MONTHS (9/29/08 TO 3/29/08) CONNECTED TO EXISTING DEV FOR FUTURE RENOVAT WORK, INCLUDES THE USE OF TEMP STRINGER LTS, CORD AND PLUG CONNECTED AS PER 2005 NEC (EAST DIST)
- ViolationPERMB- REV WK GONE BEYOND ORIG
Case 179594 · Violation 1334940 · Code A-302.10/3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationPERMB REVK- ORD/REG/CON VIOLAT
Case 179594 · Violation 1334941 · Code A-302.9/40 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationPERMB- INSTALL FIRE SUPP SYS
Case 179594 · Violation 1334942 · Code A-301.1/27 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationPERME- ALTER ELEC INSTALLATION
Case 179594 · Violation 1334943 · Code A-301.1/53 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)
Case 179594 · Violation 1334944 · Code A-504.1/3 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSWO- CONTRARY TO GOOD PRACTICE
Case 179594 · Violation 1334945 · Code A-504.1/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSWO- CONSTR W/O FIRE PERMIT
Case 179594 · Violation 1334946 · Code A-504.1/4 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- PermitMajor alteration
Permit 167225 · COMPLETED
EXTERIOR BRICK AND CONCRETE TO BE REFURBISHED NEW WINDOWS PATCH AND REPAINT STUCCO PROVIDE NEW STORE FRONT SYSTEMS AT ENTRANCES INTERIOR CREATE ARTIST STUDIOS RENOVATE EXISTING EGRESS STAIRS AND ELEVATOR FLOORS AND CEILING TO BE MADE SOUND AND REFINISHED TOTAL STUDIOS -96 PER PLANS
- InvestigationBP_BLDG
Case 179594 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitUse
Permit 177939 · COMPLETED
CHANGE USE FROM 110 ARTIST STUDIOS TO 96 ARTISTS STUDIOS. USE REMAINS THE SAME.
- ViolationCONTRACTOR & BP LIC NEEDED
Case 178166 · Violation 1126672 · Code 9-1004.2/2 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBC INSP (likely: building-code inspection)
Case 178164 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationBP_BLDG
Case 178166 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitDemolition
Permit 152299 · COMPLETED
INTERIOR DEMO. TAKING DOWN NON BEARING PARTITIONS
- PermitUse
Permit 133165 · COMPLETED
USE PERMIT FOR 110 WORKING ARTIST STUDIOS ON FLOOR 1-3
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 58558 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 58558 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Where this comes from
- Assessment, spec sheet & owner: OPA Property Assessments, Office of Property Assessment
- Sales & deed history: Realty Transfer Tax records, Recorder of Deeds
- Permits, violations & inspections: L&I Property History · Atlas
- Tax delinquency snapshot · June 2022: Real Estate Tax Delinquencies, Dept. of Revenue
- Historical tax ledger & liens · through 2016: Real Estate Tax Balances, Dept. of Revenue
- Current property-tax balance: Verify with Philadelphia Revenue
- Zoning appeals: L&I & Zoning Board appeals
- Neighborhood income & rents: US Census ACS 5-year estimates
- Historical mortgage rates: Freddie Mac Primary Mortgage Market Survey, annual averages
- Imagery: Street photo © Google · Aerial © Esri, Maxar
Methodology & freshness
This report was assembled Jul 23, 2026, 5:56 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)