Commercial property report

2716 South St

1,000,000 sqftCMX3

Property at a glanceCommercial

Individual owner on record

2026 assessment
$79M OPA value, not a listing price
2027 published assessment
$79M Future roll, not the current tax bill
Neighborhood area
Graduate Hospital · Point Breeze Approximate · based on ZIP 19146
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar
Open L&I record

1 violation row marked OPEN in 1 active case

The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.

Open City history ↗
Case CF-2024-122897

Plans Required To Comply

IN VIOLATION - COURT

Opened Nov 25, 2024 · Latest inspection FAILED · Aug 6, 2025

  • Plans Required To ComplyA-301.6/1

OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $78,594,300. It is not yet the billed-year tax basis.

$0$50M$100M$79M201420172020202320262027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record168 events · exact dates, newest first
  1. PermitShelter/Platform
  2. CertificationSprinkler Certification
  3. PermitSign
  4. PermitAddition and/or Alteration
  5. InspectionL&I investigation
  6. InspectionL&I investigation
  7. InspectionL&I investigation
  8. PermitNew Construction
  9. InspectionL&I investigation
  10. PermitTank Install/Removal
  11. AppealZBA Permit Denial - Variance
  12. AppealPAB Permit Denial
  13. InspectionL&I investigation
  14. PermitAddition and/or Alteration
  15. PermitNew Construction
  16. PermitSigns (Accessory / Non-Accessory)
  17. InspectionL&I investigation
  18. CertificationFire Alarm Certification
  19. InspectionL&I investigation
  20. InspectionL&I investigation
  21. AppealPAB Violation Appeal
  22. InspectionL&I investigation
  23. PermitAddition and/or Alteration
  24. CertificationSprinkler Certification
  25. L&I violationWORK NOT ACCORDING TO PLANS
  26. InspectionL&I investigation
  27. InspectionL&I investigation
  28. InspectionL&I investigation
  29. PermitAlterations
  30. PermitAddition and/or Alteration
  31. PermitAddition and/or Alteration
  32. PermitAddition and/or Alterations
  33. PermitAddition and/or Alteration
  34. InspectionL&I investigation
  35. PermitAddition and/or Alterations
  36. PermitAddition and/or Alteration
  37. L&I violationWORK NOT ACCORDING TO PLANS
  38. InspectionL&I investigation
  39. PermitAddition and/or Alteration
  40. L&I violationPLANS REQUIRED TO COMPLY
  41. InspectionL&I investigation
  42. PermitAddition and/or Alterations
  43. PermitAddition and/or Alteration
  44. PermitAddition and/or Alteration
  45. PermitAddition and/or Alterations
  46. PermitAddition and/or Alteration
  47. InspectionL&I investigation
  48. PermitNew Construction
  49. PermitAddition and/or Alteration
  50. InspectionL&I investigation
  51. PermitAddition and/or Alterations
  52. L&I violationDUCTWORK
  53. InspectionL&I investigation
  54. CertificationSprinkler Certification
  55. AppealBBS Permit Denial
  56. PermitAddition and/or Alterations
  57. LicenseSP Plus Corporation: Public Garage / Parking Lot business license initially issued
  58. PermitNew Construction or Additions
  59. CertificationFire Alarm Certification
  60. PermitNew Construction
  61. PermitAddition and/or Alterations
  62. CertificationSprinkler Certification
  63. PermitAddition and/or Alteration
  64. PermitTower Crane
  65. PermitAddition and/or Alterations
  66. PermitAlterations
  67. PermitAddition and/or Alteration
  68. PermitAddition and/or Alteration
  69. PermitAddition and/or Alteration
  70. PermitNew construction, addition, GFA change
  71. PermitTemporary Tents and Canopies
  72. PermitAddition and/or Alteration
  73. PermitNew Construction
  74. InspectionBP_BLDG
  75. L&I violationUNAPPROVED MAT'L ETC
  76. InspectionBP_BLDG
  77. PermitAddition and/or Alteration
  78. PermitSuppression
  79. PermitSuppression
  80. PermitElectrical
  81. PermitMechanical
  82. PermitPlumbing
  83. PermitNew Construction
  84. LicenseCHILDREN'S HOSPITAL OF PHILADELPHIA: Public Garage / Parking Lot business license marked inactive
  85. PermitSuppression
  86. PermitNew construction
  87. PermitMajor alteration
  88. PermitElectrical
  89. PermitAdministrative
  90. PermitMechanical
  91. PermitPlumbing
  92. PermitElectrical
  93. PermitMajor alteration
  94. AppealRB_LIRB
  95. PermitMechanical
  96. PermitSuppression
  97. PermitMajor alteration
  98. PermitAdministrative
  99. LicenseCHILDREN'S HOSPITAL OF PHILADELPHIA: Public Garage / Parking Lot business license initially issued
  100. PermitSuppression
  101. PermitElectrical
  102. PermitElectrical
  103. PermitSuppression
  104. PermitSuppression
  105. PermitPlumbing
  106. PermitMechanical
  107. PermitMechanical
  108. PermitNew construction
  109. PermitAdministrative
  110. PermitMechanical
  111. PermitSuppression
  112. PermitMajor alteration
  113. PermitNew construction
  114. PermitPlumbing
  115. PermitUse
  116. LicenseWATERFRONT GOURMET: Food Preparing and Serving business license initially issued
  117. PermitElectrical
  118. PermitAdministrative
  119. PermitMajor alteration
  120. PermitAdministrative
  121. AppealBuilding standards appeal
  122. PermitSuppression
  123. PermitSuppression
  124. PermitUse
  125. PermitAdministrative
  126. PermitAdministrative
  127. PermitSign
  128. PermitElectrical
  129. PermitZoning/use
  130. PermitSign
  131. AppealZoning board appeal
  132. PermitSuppression
  133. PermitZoning/use
  134. PermitSuppression
  135. AppealZoning board appeal
  136. PermitElectrical
  137. PermitMechanical
  138. PermitSuppression
  139. PermitSuppression
  140. PermitSuppression
  141. PermitPlumbing
  142. PermitSuppression
  143. PermitElectrical
  144. PermitSuppression
  145. PermitMajor alteration
  146. PermitSuppression
  147. PermitElectrical
  148. PermitMechanical
  149. PermitSuppression
  150. PermitElectrical
  151. PermitPlumbing
  152. PermitAdministrative
  153. PermitElectrical
  154. PermitAddition
  155. PermitNew construction
  156. PermitPlumbing
  157. PermitPlumbing
  158. PermitZoning/use
  159. PermitZoning admin review
  160. PermitNew construction
  161. PermitNew construction
  162. PermitZoning/use
  163. PermitZoning admin review
  164. PermitZoning admin review
  165. PermitDemolition
  166. PermitDemolition
  167. PermitZoning/use
  168. PermitZoning

Verify the public record

$110,016/year estimated property tax

2026 taxable assessment $7,859,430 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $78,594,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 772607100
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $7,859,430 of $78,594,300 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources Record found

$48,499.23 was recorded for this parcel in Philadelphia's June 2022 delinquency snapshot for 2021. That amount may have been paid, reduced, or increased since; it is not a current payoff figure.

$38,841.74 principal$2,039.19 interest$2,330.50 penalty$5,287.80 other charges
1year recorded 2021tax period 2022-02-15last payment in snapshot Yesactionable flag Nopayment agreement Nobankruptcy flag Noassessment appeal

The snapshot’s 2022 context used $78,594,300 total assessment, $7,859,430 taxable, and $70,734,870 exempt/abated. Those historical fields can differ from today’s OPA exemption status.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

$48K · Jun 2022 delinquency snapshot

What it is
Commercial Health Fac Masonry+Other
Owner
Individual owner on record Individual name redacted
$ / sq ft
$79 below the $151 median for 7,668 commercial parcels citywide
Interior area
1,000,000 sqft
Lot size
370,895 sqft
Zoning
CMX3

Block context

2700 block of South St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 2700-14 South St  ·  2700-14 South St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
SP Plus CorporationActive

Public Garage / Parking Lot · Initial issue date Dec 18, 2023 · Filed expiration Dec 17, 2026

CHILDREN'S HOSPITAL OF PHILADELPHIAInactive

Public Garage / Parking Lot · Initial issue date Feb 20, 2018 · Terminal license date Apr 20, 2019

WATERFRONT GOURMETActive

Food Preparing and Serving · Initial issue date Jun 15, 2017 · Filed expiration Jun 14, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 168 dated rows
  1. PermitShelter/Platform

    Permit GP-2026-002132 · Issued

    - Erection of a sidewalk one story shelter platform as per Engineered Plans.

  2. CertificationSprinkler Certification

    Certification BC-2026-016168 · Certified

    Expires 2027-04-20

  3. PermitSign

    Permit GP-2026-002326 · Issued

    FOR THE INSTALLATION OF TWO (2) ILLUMINATED WALL SIGNS. *************SEPARATE ELECTRICAL PERMIT REQUIRED. ***********

  4. PermitAddition and/or Alteration

    Permit EP-2026-002437 · Issued

    Furnish & Install Breakers ,conduit , relocated panel, wire and connections per APPROVED plans and specifications -2017 NEC.

  5. InvestigationL&I investigation

    Case CF-2025-017028 · PASSED

    The cited inspection visit was marked passed.

  6. InvestigationL&I investigation

    Case CF-2025-017028 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  7. InvestigationL&I investigation

    Case CF-2025-017028 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  8. PermitNew Construction

    Permit EP-2025-011133 · Issued

    Furnish and install new equipment and cabling for a certified 800mhz ERRCS system per code bulletin F-1602. Provide and install new head end equipment on Levels 14, 11, and 3. Provide and install new Dragon Skin cable to the new roof top antenna. Provide and install new fiber to 2 locations .Provide and install new plenum rated coax to the splitters and antennas. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER APPROVED PLANS.

  9. InvestigationL&I investigation

    Case CF-2025-017028 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  10. PermitTank Install/Removal

    Permit GP-2025-004908 · Completed

    FOR THE INSTALLATION OF TWO (2) 15,000 GALLON UNDERGROUND STORAGE TANKS AS PER APPROVED PLANS.

  11. AppealZBA Permit Denial - Variance

    Appeal ZP-2025-001404 · Completed · Granted with conditions

    Related permit ZP-2025-001404 · Permit for the erection of six directional signs (two faces each), one free-standing sign (two faces), one window sign, and two internally illuminated channel letter wall signs.

  12. AppealPAB Permit Denial

    Appeal PP-2023-006296 · Completed · Approved

    It is listed in section 1002.1 stating that the vertical distance from the fixture outlet to the trap weir shall not exceed 24”. With the design of the building not allowing the exact dimensions stated above we were forced to vary from th

  13. InvestigationL&I investigation

    Case CF-2024-122897 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  14. PermitAddition and/or Alteration

    Permit EP-2025-006906 · Issued

    Install 6 Fire Alarm Pre-action panels and heat detectors on Floors 7, 13, 14 . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS -2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  15. PermitNew Construction

    Permit EP-2025-007326 · Issued

    INSTALL EXTERIOR LIGHTING AND LIGHTING CONTROL. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.

  16. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2025-001404 · Issued

    For the erection of six directional signs (two faces each), one free-standing sign (two faces), one window sign, and two internally illuminated channel letter wall signs.

  17. InvestigationL&I investigation

    Case CF-2025-017028 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  18. CertificationFire Alarm Certification

    Certification BC-2025-022259 · Certified

    Expires 2026-07-09

  19. InvestigationL&I investigation

    Case CF-2024-122897 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  20. InvestigationL&I investigation

    Case CF-2025-017028 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  21. AppealPAB Violation Appeal

    Appeal HA-2025-000964 · In Process · Continued

    It is listed in section 1002.1 stating that the vertical distance from the fixture outlet to the trap weir shall not exceed 24”. We ask that the inspection write a violation that we are not in compliance in order to go in front of the PAB.

  22. InvestigationL&I investigation

    Case CF-2025-017028 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  23. PermitAddition and/or Alteration

    Permit EP-2025-002684 · Completed

    Provide and install 3,679 Cat6a plenum cables at 150' average for network, wireless and CCTV locations. Provide and install plenum composite security cable to 296 doors at 150' average. Provide and install 48 ea. 65" displays for AV. All work will be completed per current NEC. No rescue systems work-2017 NEC .

  24. CertificationSprinkler Certification

    Certification BC-2025-028268 · Certified

    Expires 2026-04-22

  25. ViolationWORK NOT ACCORDING TO PLANS

    Case CF-2025-017028 · Violation VI-2025-012955 · Code A-302.10/2 · COMPLIED

    Resolution: COMPLIED - VARIANCE GRANTED City marked this violation complied with; check the resolution date and live case for what was accepted.

  26. InvestigationL&I investigation

    Case CF-2024-122897 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  27. InvestigationL&I investigation

    Case CF-2025-017028 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  28. InvestigationL&I investigation

    Case CF-2024-126585 · PASSED

    The cited inspection visit was marked passed.

  29. PermitAlterations

    Permit PP-2025-002047 · Completed

    Plumbing Permit (Interior) for combo CP-2025-000328

  30. PermitAddition and/or Alteration

    Permit EP-2025-000928 · Completed

    REMOVE AND INSTALL NEW LIGHTING AND RECEPTACLE OUTLETS. INSTALL NEW 30 AMP CIRCUIT FOR MECHANICAL MINI SPLIT ACCORDING TO THE 2017 NEC AND PER PLANS.

  31. PermitAddition and/or Alteration

    Permit EP-2025-001420 · Completed

    Electrical Permit for combo CP-2025-000328

  32. PermitAddition and/or Alterations

    Permit MP-2025-000896 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  33. PermitAddition and/or Alteration

    Permit CP-2025-000328 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO ELEVATOR SHAFT WITHIN AN EXISTING MEDICAL BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  34. InvestigationL&I investigation

    Case CF-2024-122897 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  35. PermitAddition and/or Alterations

    Permit FP-2025-000028 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (1) sprinkler head to accommodate interior alterations

  36. PermitAddition and/or Alteration

    Permit CP-2024-006484 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO STORAGE ROOMS ON LEVEL A OF AN EXISTING MEDICAL OFFICE AND RESEARCH BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  37. ViolationWORK NOT ACCORDING TO PLANS

    Case CF-2024-126585 · Violation VI-2024-098029 · Code A-302.10/2 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  38. InvestigationL&I investigation

    Case CF-2024-126585 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  39. PermitAddition and/or Alteration

    Permit EP-2024-008829 · Issued

    INSTALL A NEW FIRE ALARM LIFE SAFETY SYSTEM. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. *IN LIEU OF FIRE FIGHTER JACKS AN ERRCS SYSTEM WILL BE INSTALLED. ** THE ERRCS SYSTEM WILL BE INSTALLED UNDER A SEPARATE ELECTRICAL PERMIT. AMENDMENT: Temporary fire alarm and monitoring of Fire Pump, Sprinkler, and temp generator from Roberts Building data Loop. AMENDMENT # 2 : Additional fire alarm speakers in cold rooms and warm room, flrs 5,3 .4 , 11(SEE CLOUDED AREAS)

  40. ViolationPLANS REQUIRED TO COMPLY

    Case CF-2024-122897 · Violation VI-2024-094858 · Code A-301.6/1 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  41. InvestigationL&I investigation

    Case CF-2024-122897 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  42. PermitAddition and/or Alterations

    Permit MP-2024-004839 · Expired

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  43. PermitAddition and/or Alteration

    Permit EP-2024-010495 · Expired

    REMOVE THE SIX EXISTING RECEPTACLE OUTLETS & WIRING . REWIRE THE EXISTING OCCUPANCY SENSOR TO CONTROL THE EXISTING SIX LIGHT FIXTURES. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.

  44. PermitAddition and/or Alteration

    Permit CP-2024-005409 · Expired

    FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  45. PermitAddition and/or Alterations

    Permit MP-2024-000045 · Issued

    FOR THE INSTALLATION OF APPLIANCES NOT CONNECTED TO DUCTWORK AND ASSOCIATED PIPING ONLY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  46. PermitAddition and/or Alteration

    Permit EP-2024-006385 · Issued

    Interior fit out of a new core and shell research building. Scope of work is limited to branch circuiting from load side of panelboards, lighting and lighting controls, receptacles, floor boxes, wiremold & furniture feeds, power for the mechanical , HVAC & lab equipment. Tele/data and security rough in only. Scope of work is also limited to floors 3,4,5,6,7,7m,8,9,10, and 11th floors. All work in accordance with the 2017 NEC. * NO FIRE ALARM WORK.

  47. InvestigationL&I investigation

    Case CF-2024-036935 · PASSED

    The cited inspection visit was marked passed.

  48. PermitNew Construction

    Permit MP-2024-002177 · Issued

    FOR THE INSTALLATION OF NEW HVAC APPLIANCES (INCLUDING VAV BOXES, EXHAUST FANS, AND FAN COIL UNITS), GRDs, AND ASSOCIATED DUCTWORK AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE CP-2022-006497 FOR ASSOCIATED BUILDING PERMIT.

  49. PermitAddition and/or Alteration

    Permit EP-2024-005413 · Issued

    Branch circuit wiring for fit-out of levels A, B, C , 2nd floor and floors 12 thru 16th. Install Lighting, switches, sensors, lighting controls, receptacles & wiring devices. Install site lighting. Provide power for the mechanical, HVAC & lab equipment. Provide temporary power & lighting. All work in accordance with the 2017 NEC. ** No fire alarm work on this permit.

  50. InvestigationL&I investigation

    Case CF-2024-036935 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  51. PermitAddition and/or Alterations

    Permit FP-2024-000748 · Issued

    FOR THE INSTALLATION OF SPRINKLER HEADS, STANDPIPES, REPLACING FIRE PUMPS FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH EXISTING BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13,14, & 20 . ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.

  52. ViolationDUCTWORK

    Case CF-2024-036935 · Violation VI-2024-030120 · Code A-301.1/43 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  53. InvestigationL&I investigation

    Case CF-2024-036935 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  54. CertificationSprinkler Certification

    Certification BC-2024-015692 · Certified

    Expires 2025-04-22

  55. AppealBBS Permit Denial

    Appeal EP-2023-003790 · Completed · Approved

    Revisions to design of Service entrance conductors associated with new construction proposed by Children's Hospital of Philadelphia.

  56. PermitAddition and/or Alterations

    Permit FP-2023-002861 · Issued

    FOR THE INSTALLATION OF TEMPORARY STANDPIPE AS PER APPROVED PLANS.

  57. License issue eventSP Plus Corporation: Public Garage / Parking Lot business license initially issued

    License 940243 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  58. PermitNew Construction or Additions

    Permit PP-2023-006296 · Issued

    Amendment to allow vertical distance of the trap from the fixture outlet to exceed the 24" allowed under 1002.1 PPC per decision of PAB Meeting MI-2025-004689 held 8/7/2025 New Sanitary, Storm, Domestic Water & Lab Gases for a Research Building Equipment Below that was not listed on Eclipse 11- Electric Water Coolers 19- Wall Boxes 11- Ice Maker Boxes

  59. CertificationFire Alarm Certification

    Certification BC-2024-003921 · Certified

    Expires 2024-07-13

  60. PermitNew Construction

    Permit EP-2023-003790 · Issued

    AMENDMENT: Revise the installation requirements to allow for the installation and connection of the new fire pumps being installed under the base contract work to the permanent electrical system of the facility along with connection of the fire pumps to a temporary generator system. The temporary provisions will allow the fire pumps to be put into service and allow for other utility installation work to be completed. The permanent emergency generator system in the facility is currently under construction. Amended 2/13/2024 - Revisions to design of Service entrance conductors associated with new construction proposed by Children's Hospital of Philadelphia. Work as approved by BBS Variance - MI-2024-000299- 1/25/2024 Grant Variance with the following provisos: 1. Allow a 6" fully grouted Concrete Masonry Unit shaft for the conductors. 2. Allow rated access panels at 3 locations in rated electrical rooms in the shafts noted in proviso number 1. 3. Allow service disconnect at level 7. Installation of temporary Service. Installation of 400A, 13.2KV permanent PECO Service and associated electrical equipment. Installation of new 13.2KV electrical distribution equipment. Installation of new substation transformers, secondary 480V distribution equipment, all switchboards, panelboards and 120/208V transformation. Installation of Qty: (3) new roof mounted generators, paralleling gear and transfer switches. Normal and emergency buss duct risers. ** Core & shell work only. Mechanical equipment branch circuits, feeders and terminations. Electrical distribution equipment branch circuits, feeders and terminations. As per 2017 nec

  61. PermitAddition and/or Alterations

    Permit FP-2023-001214 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (25) sprinklers to accommodate interior alterations on 6th floor

  62. CertificationSprinkler Certification

    Certification BC-2023-013950 · Certified

    Expires 2024-05-05

  63. PermitAddition and/or Alteration

    Permit EP-2023-002555 · Completed

    Renovations to existing office. Install lighting, receptacles, exit/emergency lights, (1) 15KVA transformer, (1) 60 amp MCB panel, and telecommunication wiring as per 2017 NEC. Install fire alarm as per 2016 NFPA 72. Amendment: Removal of electrical equipment due to equipment availability.

  64. PermitTower Crane

    Permit GP-2023-002123 · Completed

    FOR THE SUPPLEMENT TO BUILDING PERMIT CP-2022-006497, ISSUED FOR FOR ERECTION OF AN ADDITION AS PART OF AN EXISTING HIGH-RISE DETACHED STRUCTURE. PERMIT TO BE APPROVED FOR THE ASSEMBLY AND DISASSEMBLY OF ASSOCIATED TOWER CRANE TO BE LOCATED ENTIRELY WITHIN PROPERTY LINES, NO ENCROACHMENT OF PUBLIC FOOTWAYS PROPOSED AS PER DESIGN ENGINEERED PLANS AND SPECIFICATIONS. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK.

  65. PermitAddition and/or Alterations

    Permit MP-2023-001277 · Expired

    Mechanical / Fuel Gas Permit for combo CP-2023-000564

  66. PermitAlterations

    Permit PP-2023-003646 · Expired

    Plumbing Permit (Interior) for combo CP-2023-000564

  67. PermitAddition and/or Alteration

    Permit CP-2023-000564 · Expired

    FOR LEVEL II ALTERATIONS AT THE 6TH FLOOR TO INCLUDE NEW PARTITIONS, DOORS, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  68. PermitAddition and/or Alteration

    Permit CP-2022-006497 · Issued

    FOR ERECTION OF AN ADDITION AS PART OF AN EXISTING HIGH-RISE DETACHED STRUCTURE AS PER APPROVED PLANS. FOR RESEARCH AND DEVELOPMENT, BUSINESS AND PROFESSIONAL OFFICES WITH ACCESSORY OFF STREET INTERIOR PARKING AND LOADING SPACES. BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MEP AND FP WORK. SEPARATE APPROVAL REQUIRED FROM PA L&I FOR ELEVATOR INSTALLATION.

  69. PermitAddition and/or Alteration

    Permit CP-2022-005748 · Issued

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING GARAGE PODIUM STRUCTURE FOR PREPARATIONS TO TOWER OVERBUILD ADDITION (SEPARATE PERMIT REQUIRED) AS PER APPROVED PLANS. *2018 IEBC REVIEW*

  70. PermitNew construction, addition, GFA change

    Permit ZP-2022-003877 · Issued

    FOR ERECTION OF AN ADDITION AS PART OF AN EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION/ PLANS.

  71. PermitTemporary Tents and Canopies

    Permit OP-2022-000203 · Expired

    50x245 navitrac frame tent in parking lot as per 2018 Philadelphia Fire Code

  72. PermitAddition and/or Alteration

    Permit CP-2020-000242 · Expired

    FOR LEVEL II ALTERATIONS TO CONVERT STORAGE SPACE IN TO OFFICE SPACE IN AN EXISTING BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  73. PermitNew Construction

    Permit 1031919 · Completed

    PROVIDE AND INSTALL 320 CAT 6 PLENUM CABLES @ 150' AVG. ON 19TH FLOOR--PROVIDE AND INSTALL 200 CAT 6 PLENUM CABLES @ 150' AVG ON 20TH FLOOR--ALL CABLING WILL BE INSTALLED IN J-HOOKS PER NEC 2017--ALL PENETRATIONS WILL BE FIRE STOPPED PER NEC 2017- **NO FIRE ALARM OR RESCUE SYSTEM WORK ON THIS PERMIT**

  74. InvestigationBP_BLDG

    Case 704076 · PASSED

    The cited inspection visit was marked passed.

  75. ViolationUNAPPROVED MAT'L ETC

    Case 704076 · Violation 5166248 · Code A-203.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  76. InvestigationBP_BLDG

    Case 704076 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  77. PermitAddition and/or Alteration

    Permit 986909 · Expired

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CREATE MOCK-UP OFFICES ON THE 16TH FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  78. PermitSuppression

    Permit 995430 · COMPLETED

    ALTERATIONS TO EXISTING AUTOMATIC SPRINKLER SYSTEM TO ACCOMMODATE FINAL OFFICE TENANT LAYOUT ON THE 20TH FLOOR OF A NEW BUILDING IN ACCORDANCE WITH NFPA 13 AND AS PER APPROVED PLANS. SEE PERMIT 717720 FOR ORIGINAL SHELL INSTALLATION FOR 20TH FLOOR AND SEE PERMIT 661968 FOR INSTALLATION OF MAINS, PUMP, BACKFLOW & STANDPIPE INSTALLATIONS.

  79. PermitSuppression

    Permit 975033 · COMPLETED

    ALTERATIONS TO EXISTING AUTOMATIC SPRINKLER SYSTEM TO ACCOMMODATE FINAL OFFICE TENANT LAYOUT ON THE 19TH FLOOR OF A NEW BUILDING IN ACCORDANCE WITH NFPA 13 AND AS PER APPROVED PLANS. SEE PERMIT 717720 FOR ORIGINAL SHELL INSTALLATION FOR 19TH FLOOR AND SEE PERMIT 661968 FOR INSTALLATION OF MAINS, PUMP, BACKFLOW & STANDPIPE INSTALLATIONS.

  80. PermitElectrical

    Permit 970159 · COMPLETED

    F&I EXTENSION OF EXISTING FIRE ALARM AS PER NFPA 72 AND F&I RECEPTACLES, POKE-THRU & BRANCH WIRING, LIGHTING FIXTURES, SWITCHING/CONTROLS, BRANCH LIGHTING CIRCUITS, COMMUNICATION CABLE TRAY, PROVISION ONLY FOR TELE/DATA & 100A BUS PLUGS & 45KVA TRANSFORMERS & 150A PANELS

  81. PermitMechanical

    Permit 974213 · COMPLETED

    INSTALLATION OF A NEW MECHANICAL SYSTEM TO ACCOMMODATE THE 19TH AND 20TH FLOOR OF AN EXISTING HIGH-RISE BUILDING . SYSTEM TO INCLUDE NEW HVAC SYSTEM, AIR HANDLERS AND ALL ASSOCIATED DUCTWORK AS PER APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR ANY PLUMBING, ELECTRICAL OR FIRE SUPPRESSION WORK**

  82. PermitPlumbing

    Permit 974206 · COMPLETED

    INSTALL NEW SANITARY VENT AND DOMESTIC WATER PIPING TO NEW RESTROOM AND BREAK AREAS FOR FLOORS 19 AND 20 OFFICE SPACE FIT OUT AT CHOP ROBERTS CENTER FOR PEDIATRIC RESEARCH. NEW FIXTURES WILL BE INSTALLED AS WELL IN THE DESIGNATED RESTROOMS AND BREAK AREAS.

  83. PermitNew Construction

    Permit 962063 · Completed

    PROVIDE EMT CONDUIT FROM EXISTING PANEL IN ELECTRICAL CLOSET #3003 TO THE TOP OF DOOR #3050-3.2. F&I NEW 110V CKT IN NEW CONDUIT SYSTEM AND TIE INTO NEW DOOR SECURITY EQUIPMENT AS F&I INSTALLED BY OTHERS. PROVIDE CONDUIT PROVISIONS ONLY FOR NEW DOOR

  84. License terminal eventCHILDREN'S HOSPITAL OF PHILADELPHIA: Public Garage / Parking Lot business license marked inactive

    License 766411 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  85. PermitSuppression

    Permit 964466 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  86. PermitNew construction

    Permit 957664 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR AN OFFICE FIT OUT ON THE 19TH AND 20TH FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  87. PermitMajor alteration

    Permit 946715 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CREATE TWO MOCK-UP OFFICES ON THE 18TH FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  88. PermitElectrical

    Permit 925451 · COMPLETED

    1) SELECT DEMOLITION ON THE 21ST FLR. FOR NEW BATHROOM. 2) F&I RECEPTACLE & LIGHTING LIGHTING CONTROLS , BRANCH LIGHTING & POWER CIRCUITS 4) F&I NEW FA DEVICES IN NEW BATHROOM ON FLOOR 21. 5) PROVIDE FEEDER TO NEW SF-8-01. 6) PROVIDE NEW BRANCH CIRCUIT TO NEW BAS CABINET. AS PER NEC 2008 CC DISTRICT

  89. PermitAdministrative

    Permit 932403 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY ** EXCLUDING KITCHEN CATERING**

  90. PermitMechanical

    Permit 924705 · COMPLETED

    FOR ALTERATIONS TO PREVIOUSLY APPROVED MECHANICAL SYSTEM WITHIN LEVEL B, AREA 3, AND ON THE 21ST FLR WITHIN THE BUILDING MAINTENANCE ROOM, WITHIN AN EXISTING HIGH-RISE MEDICAL OFFICE BUILDING, AS PER PLANS; NO OTHER WORK ON THIS PERMIT; SEE AP#641577 FOR PREVIOUSLY APPROVED MECHANICAL SYSTEM.

  91. PermitPlumbing

    Permit 905103 · COMPLETED

    FURNISH AND INSTALL 4 FLOOR DRAINS AND 2 SINKS (OFFICE SPACE)

  92. PermitElectrical

    Permit 903357 · COMPLETED

    F & I NEW RECEPTACLES,POKE-THRUS AND BRANCH WIRING. F& I NEW LIGHTING FIXTURES,SWITCHING/CONTROLS AND BRANCH LIGHTING CIRCUITS AND F& I PROVISION ONLY FOR TELE/DATA PER 2008 NEC (OFFICE BLDG)F & I EXTENSION OF EXISTING FIRE ALARM PER NFPA 72

  93. PermitMajor alteration

    Permit 915563 · COMPLETED

    ALTERATIONS INCLUDING EYEWASH INSTALLATION, TOILET ROOM INSTALLATION, FIRE PUMP ROOM RENOVATION, EXTERIOR HAND RAIL MODIFICATION. **SEPERATE PERMITS WILL BE REQUIRED FOR FIRE SUPPRESSION, PLUMBING & ELECTRICAL**

  94. AppealRB_LIRB

    Appeal 35178 · CLOSED · Withdrawn

    RELATING TO THE DURATION OF MONTHLY FIRE PUMP TESTING, IS INCONSISTENT WITH NATIONAL FIRE PROTECTION ASSOCIATION GUIDELINES FOR TESTING.

  95. PermitMechanical

    Permit 905110 · COMPLETED

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES TO BUSINESS OCCUPANCY ACCESSORY TO EXISTING HEALTH FACILITY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  96. PermitSuppression

    Permit 905507 · COMPLETED

    )- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  97. PermitMajor alteration

    Permit 899176 · COMPLETED

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATINOS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  98. PermitAdministrative

    Permit 864250 · COMPLETED

    TCO FOR FLOORS 3,12 AND 17 EXCEPT LOCKER ROOMS AND FITNESS CENTER ON 3RD FLOOR.

  99. License issue eventCHILDREN'S HOSPITAL OF PHILADELPHIA: Public Garage / Parking Lot business license initially issued

    License 766411 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  100. PermitSuppression

    Permit 849017 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  101. PermitElectrical

    Permit 816815 · COMPLETED

    FURNISH AND INSTALL EXTENSION OF EXISTING FIRE ALARM AS PER NFPA72 FURNISH & INSTALL NEW RECEPTS, POKE THRUS & BRANCH WIRING, NEW LIGHT FIXTURES, SWITCH CONTROLS AND BRANCH LIGHT CIRCUTIS,, COMMUNICATION CABLE TEAY & PROVIDE TELE/DATA ONLY AS PER 2008 NEC (SOUTH DISTRICT)

  102. PermitElectrical

    Permit 821731 · COMPLETED

    FIT OUT NEW LIGHTING FIXTURES & LIGHTING CONTROLS, NEW LIGHTING BRANCH CKTS, NEW RECEPTACLES AND BRANCH WIRING AS PER NEC 2008 SOUTH DISTRICT & ALTERATION TO EXISTING FIRE ALARM SYSTEM AS PER NFPA 72

  103. PermitSuppression

    Permit 821573 · COMPLETED

    ALTERATIONS TO EXISTING AUTOMATIC SPRINKLER SYSTEM TO ACCOMODATE FINAL OFFICE TENANT LAYOUT ON THE 12TH FLOOR OF A NEW BUILDING IN ACCORDANCE WITH NFPA 13 AND AS PER APPROVED PLANS. SEE PERMIT 698368 FOR ORIGINAL SHELL INSTALLATION FOR 12TH FLOOR AND SEE PERMIT 661968 FOR INSTALLATION OF MAINS, PUMP, BACKFLOW & STANDPIPE INSTALLATIONS.

  104. PermitSuppression

    Permit 825293 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  105. PermitPlumbing

    Permit 813478 · COMPLETED

    INSTALL NEW HOT & COLD & SANITARY LINES TO NEW PANTRY, LAVY SINK FIXTURE IN OFFICE AND ON FL 3RD, 12TH & 17TH INSTALL BATHROOM FIXTURES IN MENS & WOMENS LOCKER ROOMS AND FITNESS AREA ON LEVEL 3 - THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  106. PermitMechanical

    Permit 821728 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  107. PermitMechanical

    Permit 821732 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  108. PermitNew construction

    Permit 809782 · COMPLETED

    LANDLORD IMPROVEMENT WITHIN AN EXISTING DEMISED SPACE AS A VANILLA BOX FOR FUTURE FIT-OUT AS A BANK WITHIN THE 1ST FLOOR OF THE BUILDING. WORK TO INCLUDE NEW AND PATCH REPAIR TO EXISTING PARTITIONS, NEW GWB SOFFITS AND CEILING GRID AND CEILING TILE, AND INSTALLATION OF NEW MECHO SHADES. SEPARATE MEP PERMITS REQUIRED. CO NOT INCLUDED WITH THIS PERMIT BUT WILL BE REQUIRED WITH FINAL FIT-OUT PERMIT.

  109. PermitAdministrative

    Permit 809564 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR A SPECIAL EVENT OCCURRING ON OCTOBER 07, 2017 ON FLOORS 1, 16, AND 17, OF A HIGH-RISE MEDICAL OFFICE BUILDING. PERMIT ALSO TO INCLUDE TO ERECTION AND REMOVAL OF TEMPORARY STRUCTURAL SHORING TO SUPPORT INCREASED LIVE LOADS DUE TO EVENT & INCREASED OCCUPANT LOAD. SEE BBS VARIANCE CASE# 30234 FOR APPROVED NUMBER OF EXITS PER PROPOSED OCCUPANT LOAD

  110. PermitMechanical

    Permit 813477 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR FIT-OUT OF OFFICE SPACES AND FITNESS CENTER ON THE 3RD, 12TH, 16TH & 17TH FLOORS OF A NEW CONSTRUCTION HIGH-RISE BUILDING TO INCLUDE CHILLED BEAMS, DUCTWORK, AND HOT WATER PIPE FOR FINTUBE RADIATION AS PER APPROVED PLANS.

  111. PermitSuppression

    Permit 805381 · COMPLETED

    FOR ALTERATIONS TO AN EXISTING AUTOMATIC SPRINKLER SYSTEM, ORIGINALLY APPROVED UNDER AP#717720 AND INSTALLED IN ACCORDANCE WITH NFPA 13, ON THE 17TH FLOOR OF AN EXISTING HIGH-RISE OFFICE BUILDING, USING THE EXISTING FIRE LINES, BACKFLOWS, AND FIRE PUMP SYSTEMS APPROVED UNDER AP#661968, AS PER PLANS.

  112. PermitMajor alteration

    Permit 807621 · COMPLETED

    EXISTING SHELL SPACE TO BE FITOUT FOR AN AMERICAL HERITAGE CREDIT UNION BANK, INTERIOR WORK INCLUDES FRAMING, ELECTRICAL, HVAC AND FINISHES - ADDITIONAL PERMITS ARE REQUIRED FOR HVAC AND ELECTRICAL

  113. PermitNew construction

    Permit 800437 · COMPLETED

    NEW CONSTRUCTION FIT-OUT OF 3RD, 12TH & 17TH FLOORS FOR OFFICE SPACES AND ACCESSORY FITNESS CENTER WITHIN A HIGH-RISE BUILDING (SEE NEW CONSTRUCTION PERMIT 577940) AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  114. PermitPlumbing

    Permit 794327 · COMPLETED

    INSTALL 1 TRIPLE COMPARTMENT SINK 1 ONE COMPARTMENT SINK AND 2 HAND SINKS - THE INSTALLATION WILL COMPY WITH THE PHILADEPHIA PLUBMING CODE 2004

  115. PermitUse

    Permit 792254 · COMPLETED

    USE PERMIT APPLICATION FOR A FINANCIAL INSTITUTION (BANK) IN A PORTION OF LEVEL B IN THE SAME BUILDING WITH ALL OTHER USES AS PREVIOUSLY APPROVED (AS PER KEY PLAN ATTACHED)

  116. License issue eventWATERFRONT GOURMET: Food Preparing and Serving business license initially issued

    License 742366 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  117. PermitElectrical

    Permit 785009 · COMPLETED

    WIRING OF FIXTURES AND OUTLETS FOR A SMALL CAFE AS PER NEC 2008 SOUTH DISTRICT

  118. PermitAdministrative

    Permit 769653 · COMPLETED

    FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT# 656790 TO INCLUDE THE ERECTION OF PARTITION WALL, PROVIDE FINISHES AND FURNISHING AS SHOWN PER APPROVED PLANS. ORIGINAL PERMIT APPROVED FOR AN INTERIOR FITOUT OF A PREVIOUSLY APPROVED CORE AND SHELL, ALTERATIONS TO BE COMPLETED AS PHASE I OF THE WORK TO COMPLETED. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS FROM THE FIRST THROUGH FOURTEENTH FLOOR OF THE BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. PLEASE SEE AP#577940 FOR CORE AND SHELL AND FITOUT OF DINING AREA. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  119. PermitMajor alteration

    Permit 776746 · COMPLETED

    FOR A TENANT FIT-OUT TO CREATE A NEW CAFE WITHIN AN EXISTING PROFESSIONAL OFFICE BUILDING. WORK TO INCLUDE INTERIOR NON-BEARING PARTITIONS, MILLWORK, AND FINISHES. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS.

  120. PermitAdministrative

    Permit 776375 · COMPLETED

    TCO FOR THE 15TH FLOOR DOWN.

  121. AppealBuilding standards appeal

    Appeal 30234 · OPEN · APPROVED

    Related permit 756858 · ON 3/28/2017, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #756858.

  122. PermitSuppression

    Permit 774799 · COMPLETED

    RELOCATE 70 SPRINKLER ON THE B LEVEL ON THE 21ST FLOOR

  123. PermitSuppression

    Permit 719585 · COMPLETED

    FOR THE INSTALLATION OF FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 ON THE SECOND FLOOR OF AN EXISTING STRUCTURE, AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  124. PermitUse

    Permit 768956 · COMPLETED

    FOR A PREPARED FOOD SHOP (16 SEATING)( NO COMMERCIAL KITCHEN )AT FIRST FLOOR IN THE SAME BUILDING WITH ALL OTHER USES AS PREVBIOUSLY APPROVED. NO SIGN ON THIS APPLICATION.

  125. PermitAdministrative

    Permit 768024 · COMPLETED

    TCO FOR THE 11TH FLOOR DOWN. PARENT PERMIT #577940.

  126. PermitAdministrative

    Permit 752816 · COMPLETED

    OCCUPANCY REQUESTED FOR THE 7TH FLOOR DOWN.

  127. PermitSign

    Permit 741745 · COMPLETED

    SIGN A, INSTALL ILLUM GROUND SIGN, SIGN B, INSTALL ILLUM GROUND SIGN, SIGNS C- INSTALL 2 ILLUM GROUND SIGNS, SIGN D- INSTALL 2 ILLUM GORUND SIGNS, SIGN E- INSTALL 2 NON ILLUM GROUND SIGNS. SIGN F- INSTALL 1 WALL SIGN. INSTALL 5 GROUND SIGNA NON ILLUM EACH

  128. PermitElectrical

    Permit 726966 · COMPLETED

    PROVIDE AND INSTALL 4,027 CAT6 PLENUM CABLES @150' AVERAGE,PROVIDE AND INSTALL 133 CCTV CAMERAS,83 CARD READERS,9 EMERGENCY CALL UNITS AND 55 EQUIPMENT RACKS. ALL CABLING WILL BE INSTALLED IN J HOOKS.ALL CABLING WILL BE INSTALLED IN J HOOKS.ALL PENETRATIONS WILL BE FIRE STOPPED AS PER NEC 2008 (SOUTH DISTRICT)

  129. PermitZoning/use

    Permit 709387 · COMPLETED

    FOR THE ERECTION OF SIX (6) ACCESSORY, DOUBLE-FACED, ANIMATED ILLUMINATED FREESTANDING SIGNS (ONE (1) EACH OF SIGNS "A", "B", AND TWO (2) EACH OF SIGNS "C", AND "D"), SIX (6) ACCESSORY, SINGLE-FACED, NON-ILLUMINATED FREESTANDING SIGNS (TWO (2) OF SIGN "E" AND THREE (3) OF SIGN "F"), AND ONE (1) ACCESSORY, NON-ILLUMINATED DIRECTIONAL WALL SIGN (SIGN "F" ON PLANS), SIZES AND LOCATIONS AS SHOWN ON PLANS/APPLICATION. ALL SIGNS ACCESSORY TO PREVIOUSLY APPROVED USE OF BUSINESS & PROFESSIONAL OFFICES.

  130. PermitSign

    Permit 722383 · COMPLETED

    SIGN 1.0 INSTALL SET ILLUM, CHANNEL LETTERS TO WALL. SIGN 2.0 INSTALL 1 SET OF ILLUM CHANNEL LETTERS TO WALL

  131. AppealZoning board appeal

    Appeal 28554 · CLOSED · Granted with conditions

    Related permit 709387 · PERMIT FOR THE ERECTION OF SIX (6) ACCESSORY, DOUBLE-FACED, STATICALLY ILLUMINATED FREESTANDING SIGNS (ONE (1) EACH OF SIGNS "A", "B", AND TWO (2) EACH OF SIGNS "C", AND "D"), SIX (6) ACCESSORY, SINGLE-FACED, NON-ILLUMINATED FREESTANDING SI

  132. PermitSuppression

    Permit 717720 · COMPLETED

    INSTALLATION OF WET SPRINKLER PIPING AND HEADS COMPLYING WITH NFPA 13 ON LEVELS 16 THROUGH 20 WITHIN A NEW HEALTH CARE FACILITY AS PER APPROVED PLANS. SEE A/P 661968 FOR MAIN, BACKFLOW PREVENTOR, PUMP AND STANDPIPE RISER INSTALLATION.

  133. PermitZoning/use

    Permit 697059 · COMPLETED

    FOR THE ERECTION OF ONE(1) FLATWALL SIGN ( SIGN # 1) ( AREA 1,838 SF) AT FIFTH FLOOR ; FOR THE ERECTION OF ONE(1) FLATWALL SIGN ( AT 20TH FLOOR) ( SIGN # 2) ( AREA 1,377.7 SF) OF AN EXISTING STRUCTURE SIGN ACCESSORY TO BUSINESS AND PROFESSIONAL OFFICE SIZE AND LOCATION AS SHOWN IN THE APPLICATION.

  134. PermitSuppression

    Permit 704254 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM, TIEING TO EXISTING SYSTEM, AT ELEVATOR MACHINE ROOM, STORAGE AREA AND STAIR ON THE 22ND FLOOR OF AN EXISTING STRUCTURE. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  135. AppealZoning board appeal

    Appeal 28266 · CLOSED · Granted

    Related permit 697059 · PERMIT FOR THE ERECTION OF ONE(1) FLATWALL SIGN ( SIGN # 1) ( AREA 1,838 SF) AT FIFTH FLOOR ; FOR THE ERECTION OF ONE(1) FLATWALL SIGN ( AT 20TH FLOOR) ( SIGN # 2) ( AREA 1,377.7 SF) OF AN EXISTING STRUCTURE ACCESSORY TO BUSINESS AND PROFE

  136. PermitElectrical

    Permit 686015 · COMPLETED

    F&I EXTENSION OF EXIST FIRE ALARM AS PER NFPA 72, F&I RECEPTS, POKE THRU & BRANCH WIRING, LIGHTING FIXTURES SW/CONTROL & BRANCH LIGHTING CKTS, COMMUNICATION CABLE TRAY & PROVISION ONLY FOR TELE/DATA AS PER NEC 2008

  137. PermitMechanical

    Permit 704351 · COMPLETED

    INSTALLATION OF HVAC DUCTWORK AS PER APPROVED PLANS IN NEW OFFICE BUILDING.

  138. PermitSuppression

    Permit 708960 · COMPLETED

    INSTALLING 234 SPRINKLER HEADS ON LEVEL 4 ALONG WITH ASSOCIATED SUPPLY PIPING AS PER PLANS AND NFPA 13 -HEALTH FACILITY.

  139. PermitSuppression

    Permit 698368 · COMPLETED

    INSTALLATION OF (2761) SPRINKLER HEADS ON LEVELS 5-15 ALONG WITH THE ASSOCIATED SUPPLY PIPING AS PER PLANS.

  140. PermitSuppression

    Permit 696962 · COMPLETED

    INSTALLING 372 SPRINKLER HEADS ON LEVEL 21 ALONG WITH ASSOCIATED SUPPLY PIPING AS PER PLANS -HEALTH FACILITY

  141. PermitPlumbing

    Permit 685370 · COMPLETED

    ALTERATION: INTERIOR PLUMBING ON FLOORS 1 THRU 14 FOR THE INSTALLATION OF NEW FIXTURES AND ASSOCIATED DOMESTIC AND WASTE PIPING (OFFICE SPACE) PER THE APPROVED PLANS.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004. FUEL GAS PIPING AND EQUIPMENT IS NOT PART OF THIS PERMIT.

  142. PermitSuppression

    Permit 685835 · COMPLETED

    WILL BE INSTALLING 256 SPRINKLER HEADS ON LEVEL 1, INCLUDING THE INSTALLATION OF PRE ACTION SYSTEM, SEE 661968 FOR ADDL APPROVALS.

  143. PermitElectrical

    Permit 676508 · COMPLETED

    INSTALLING A NEW PRE-ACTION CONTROL PANEL AND ASSOCIATED DETECTION DEVICES ON THE 3RD FLOOR AS PER NFPA72 (SOUTH DISTRICT)

  144. PermitSuppression

    Permit 675911 · COMPLETED

    FOR THE INSTALLATION OF FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2007, STANDARD 13, TO INCLUDE PRE-ACTION SYSTEM (IN AREA 2) AND DRY PENDANTS TO BE INSTALLED. (SEE AP#661968 FOR PA DOH APPROVAL AND FIRE PUMP/BACKFLOW PREVENTION ASSEMBLY DATA.)

  145. PermitMajor alteration

    Permit 656790 · COMPLETED

    FOR AN INTERIOR FITOUT OF A PREVIOUSLY APPROVED CORE AND SHELL, ALTERATIONS TO BE COMPLETED AS PHASE I OF THE WORK TO COMPLETED. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS FROM THE FIRST THROUGH FOURTEENTH FLOOR OF THE BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. PLEASE SEE AP#577940 FOR CORE AND SHELL AND FITOUT OF DINING AREA. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  146. PermitSuppression

    Permit 661968 · COMPLETED

    FOR THE INSTALLATION OF A NFPA 13 FIRE SUPPRESSION SYSTEM FOR A HIGH RISE SERVICED BY TWO EIGHT INCH FIRE SERVICE LINES WITH TWO BACKFLOW PREVENTERS, TWO STANDPIPES WITH THE INSTALLATION OF A DRY AND WET SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEMS TO BE INSTALLED PER NFPA 13, NFPA 14, AND NFPA 20.

  147. PermitElectrical

    Permit 651873 · COMPLETED

    INSTALLATION OF THE ELECTRICAL WIRING & DEVICES ASSOCIATED WITH THE PREACTION SPRINKLER SYSTEMS THE ELECTRICAL CIRCUITS WILL BE PROVIDED UNDER PREVIOUSLY ISSUE PERMIT 631518 PER 2008 NEC (HEALTH CARE)

  148. PermitMechanical

    Permit 641577 · COMPLETED

    INSTALLATION OF HEATING VENTILATION AND OTHER MECHANICAL CLIMATE CONTROL EQUIPMENT THROUGHOUT ADDITION (REFER TO 577940). WORK TO BE IN ACCORDANCE WITH ENGINEER CODE/PERFORMANCE CERTIFIED PLANS WITH GENERAL NOTES ON PLAN REVIEW FORM. CODE/DESIGN PROF: JONATHAN P. FRIEDAN, PE

  149. PermitSuppression

    Permit 638175 · COMPLETED

    INSTALL NEW DRY SPRINKLER SYSTEM, (2) PRV'S AND DRY VALVE WITH (440) SPRINKLERS ON LEVEL C OF THE CHOP HIGH RISE PHASE 1. 13,8" PHASE 2 ADDITIONAL INSTALLATION AT A LATER DATE.

  150. PermitElectrical

    Permit 631518 · COMPLETED

    ELECTRICAL CORE AND SHELL DISTRIBUTION PER 2008 NEC (MEDICAL OFFICE BLDG)INSTALL FIRE ALARM PER NFPA 72 SOUTH DISTRICT

  151. PermitPlumbing

    Permit 618000 · COMPLETED

    INSTALLATION OF NEW PLUMBING FIXTURES FOR OFFICE SPACE AND SHELL (OFFICE SPACE)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  152. PermitAdministrative

    Permit 616176 · COMPLETED

    AMEND PERMIT 577940 FOR THE ERECTION AND DIS-ASSEMBLY OF TOWER CRANE LOCATED COMPLETELY WITHIN PROPERTY LINES AS PER SPECS AND PLANS

  153. PermitElectrical

    Permit 595550 · COMPLETED

    INSTALL 6WAY 4"DUCT BANK & 600AMP 120/280 VOLT 3PHASE ELECTRICAL SERV & 1- 600AMP BANK TO FEED 3-200 AMP ELECTRICAL SERVICE AS PER NEC 2008 (CELL SITE)

  154. PermitAddition

    Permit 595160 · COMPLETED

    CONSTRUCTION OF A STEEL FRAME PEDESTRIAN BRIDGE SPANNING OVER THE EXISTING RAILROAD TRACKS BETWEEN PLAZA AND THE SCHUYKILL RIVER TRAIL AS PER APPROVED PLANS. SEE A/P #561836 FOR APPROVED FOUNDATION PLANS. AMENDED PERMIT REQUIRED TO APPROVE SPECIAL INSPECTORS/AGENCIES FOR ALL REQUIRED SPECIAL INSPECTIONS. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL WORK.

  155. PermitNew construction

    Permit 577940 · COMPLETED

    NEW CONSTRUCTION OF HIGH RISE STRUCTURE PHASE 1 ON PRIOR APPROVED FOUNDATION SYSTEM & UNDERGROUND STRUCTURE, FOUNDATION PERMIT HAS PRIOR ASSOCIATED APPROVALS UNDER AP561836. ASSOCIATED CIVIL SITE WORK, LANDSCAPING AND STORMWATER MGMT (APPROVED BY OTHERS). SEE ADDITIONAL ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING ,HVAC, SPRINKLERS & S.PIPES, SIGNS

  156. PermitPlumbing

    Permit 592865 · COMPLETED

    INSTALL 5"LATERAL TRAP AND DRAIN TO TEMPORARY TRAILER FOR 6 MONTHS,INSTALL 1"WATER SERVICE COMPLETE WITH BACKFLOW TO TRAILER-PA#20150501305-"SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  157. PermitPlumbing

    Permit 583638 · COMPLETED

    INSTALL 1"WATER SERVICE INTO HOT BOX COMPLETE WITH 1"RPZ VALVE AND BACKFLOW PREVENTOR-PA#20143560643-"SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  158. PermitZoning/use

    Permit 580702 · COMPLETED

    FOR THE ERECTION OF A FREESTANDING WIRELESS SERVICE FACILITY ON THE SAME LOT AS A PREVIOSULY APPROVED DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS WIRELESS SERVICE FACILITY ON THE SAME LOT AS PREVIOSULY APPROVED BUSINESS AND PROFESSIONAL OFFICE WITH ACCESSORY PARKING.

  159. PermitZoning admin review

    Permit 575296 · COMPLETED

    TO AMEND A/P NO 570752 TO REFLECT ACCURATE APPLICANT (LF DRISCOLL CO. LLC). A/P NO 570752 WAS APPROVED FOR THE ERECTION OF A FREESTANDING WIRELESS SERVICE FACILITY ON THE SAME LOT AS A PREVIOUSLY APPROVED DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS WIRELESS SERVICE FACILITY ON THE SAME LOT AS PREVIOUSLY APPROVED BUSINESS AND PROFESSIONAL OFFICE WITH ACCESSORY PARKING.

  160. PermitNew construction

    Permit 561836 · COMPLETED

    FOUNDATION ONLY PERMIT. STORMWATER MANAGEMENT, RIGHT OF WAY WORK APPROVED BY OTHERS. OWNER WILL TAKE FULL RESPONSIBILITY FOR THE ALTERATIONS,MODIFICATIONS OR REMOVAL OF FOUNDATIONS COVERED UNDER THE FOUNDATION PERMIT WHICH MAY BE REQUIRED UPON REVIEW OF THE FINAL PLANS FOR A BUILDING PERMIT FOR THIS PROPERTY. SPECIAL INSPECTIONS AGENCY REQUIRED, ENGINEER TO PROVIDE ADDITIONAL SPECIAL INSEPCTIONS AS NOTED.

  161. PermitNew construction

    Permit 567049 · COMPLETED

    FOUNDATION AND STRUCTURE PERMIT FOR CELL TOWER RELOCATION FOR CHOP.

  162. PermitZoning/use

    Permit 570752 · COMPLETED

    FOR THE ERECTION OF A FREESTANDING WIRELESS SERVICE FACILITY ON THE SAME LOT AS A PREVIOSULY APPROVED DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS WIRELESS SERVICE FACILITY ON THE SAME LOT AS PREVIOSULY APPROVED BUSINESS AND PROFESSIONAL OFFICE WITH ACCESSORY PARKING.

  163. PermitZoning admin review

    Permit 562586 · COMPLETED

    TO AMEND A/P NO 558844 AND 546098 FOR THE FOLLOWING: TO REDUCE THE FLOOR AREA OF THE PROPOSED BUILDING, TO REDUCE THE NUMBER OF PROPOSED PARKING SPACES FOR A NEW TOTAL OF FOUR HUNDRED AND SIXTY SIX (466) SPACES, TO REDUCE THE NUMBER OF BICYCLE PARKING SPACES FOR A NEW TOTAL OF FIFTY FOUR (54) SPACES, FOR THE RECONFIGURATION OF THE SURFACE PARKING LOT, FOR THE ELIMINATION OF ONE CURB-CUT TO THE SURFACE LOT ON SCHUYLKILL AVENUE, AND FOR THE RECONFIGURATION OF LEVEL-C. FOR THE DOCUMENTATION OF THE FOLLOWING ITEMS: THE LOCATION OF THE PROPOSED CELL TOWER, THE RECONFIGURATION OF THE PROMENADE ALONG THE CSX RAIL EASEMENT, THE RECONFIGURATION OF THE "SHUTTER STAIR" TO THE PLAZA AND THE CHANGE IN ROOFING MATERIAL FROM A GREEN ROOF TO A TEMPORARY GRAVEL SURFACE. SIZE AND LOCATION AS SHOWN ON PLANS AND APPLICATION.

  164. PermitZoning admin review

    Permit 558844 · COMPLETED

    TO AMEND A/P NO 546098 TO DOCUMENT THE ADDITION OF A PEDESTRIAN BRIDGE OVER THE CSX TRACKS, BOARDING THE SITE; ELIMINATION OF A SECOND DRIVEWAY FROM THE SOUTH STREET BRIDGE TO THE PROJECT SITE; CERTAIN ADJUSTMENTS IN THE GARAGE AND THE GARAGE ENTRANCE STRUCTURE IN RESPONSE TO RCO CONCERNS REGARDING AESTHETICS; AND, THE ADDITION OF THREE (3) SHORT TERM PARKING SPACES OFF OF THE LOOP ROAD INTERIOR TO THE PROJECT. ALL OTHER ZONING/USES AS PREVIOUSLY APPROVED.

  165. PermitDemolition

    Permit 556272 · COMPLETED

    **ASBESTOS ABATEMENT REQ'D PRIOR TO COMMENCEMENT OF WORK** SITE FORMERLY KNOWN AS 600 SCHUYLKILL AVE: COMPLETE DEMOLITION OF TWO (2) EXISTING ONE (1) STORY DETACHED METAL BUILDINGS (QUONSET HUTS) AND SMALL MOCK-UP BUILDINGS PER PLAN AND IN ACCORDANCE WITH DEPARTMENT CODE BULLETIN B-1302. PROTECTION OF PEDESTRIANS, RIGHT-OF-WAY AND ADJACENT STRUCTURES REQUIRED DURING ALL DEMOLITION ACTIVITY PER SECTION 3306 OF THE BUILDING CODE; RIGHT-OF-WAY CLOSURE REQUIRED PER APPROVED PLANS (SEPARATE PERMIT REQUIRED FROM STREETS DEPARTMENT); ANY DEVIATION FROM APPROVED PLAN SHALL REQUIRE AN AMENDED PERMIT. SEE PERMIT # 556275 FOR PLANS. 21-DAY WAITING PERIOD WAIVED PER ADMIN. CODE SECTION A-303.2; CONTACT INSPECTOR PRIOR TO START OF WORK. SEPARATE PLUMBING PERMIT REQUIRED FOR SEWER LATERAL CAP / SEAL.

  166. PermitDemolition

    Permit 556275 · COMPLETED

    **ASBESTOS ABATEMENT REQ'D PRIOR TO COMMENCEMENT OF WORK** SITE FORMERLY KNOWN AS 700 SCHUYLKILL AVE: COMPLETE DEMOLITION OF SIX (6) STORY DETACHED BUILDING BY MECHANICAL MEANS PER PLANS; NOTE LIMITATIONS ON PERMITTED EQUIPMENT USE AT "ORIGINAL" AND "ADDITION" PORTIONS OF BUILDING PER ENGINEER'S STRUCTURAL SURVEY; PROTECTION OF ADJACENT OPERATIONAL RAILWAY TO BE MAINTAINED AT ALL TIMES, FLAGGER ON-SITE PER ENGINEER'S CORRESPONDENCE; PEDESTRIAN PROTECTION AND RIGHT-OF-WAY CLOSURE REQUIRED PER PLANS AND PER SECTION 3306 OF BUILDING CODE (SEPARATE STREETS DEPARTMENT APPROVAL REQUIRED). 21-DAY WAITING PERIOD WAIVED PER ADMIN. CODE SECTION A-303.2; CONTACT INSPECTOR PRIOR TO START OF WORK. SEPARATE PLUMBING PERMIT REQUIRED FOR SEWER LATERAL CAP / SEAL.

  167. PermitZoning/use

    Permit 546098 · COMPLETED

    FOR THE ERECTION OF ONE DETACHED STRUCTURE MAXIMUM HEIGHT 358 FT. USE AS ACCESSORY PARKING GARAGE AND LOADING SPACES ON LEVEL "C TO A" AND ABOVE BUSINESS AND PROFESSIONAL OFFICE AND FIVE HUNDRED-TWELVE (512) OFF STREET PARKING SPACES (256 SURFACE PARKING AND 256 GARAGE PARKING) INCLUDING THIRTEEN (13) ACCESSIBLE SPACES (INCLUDING TWO (2) VAN ACCESSIBLE SPACES) AND FOUR (4) OFF STREET LOADING SPACES AND FIFTY-SEVEN (57) BICYCLE PARKING SPACES LOCATED ON AN ACCESSIBLE ROUTE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION. (FOR CONSTRUCTION BUILDING PERMIT REQUIRED TO FOLLOW DESIGN TEAM RECOMMENDATION "BALLINGER" LETTER DATED 2/21/2014 AND SEE CSX TRANSPORTATION, INC.LETTER DATED 2/11/2014).

  168. PermitZoning

    Permit 542390 · COMPLETED

    RELOCATION OF LOT LINE TO CREATE ONE LOT FROM FOUR (4) OPA ACCOUNTS (TEN (10) PARCELS INCLUDING PREMISES A TO I): 600-12, 614-22 & 700 SCHUYLKILL AVE AND 2716-18 SOUTH ST .SIZE AND LOCATION AS SHOWN ON THE APPLICATION.

Where this comes from

Methodology & freshness

This report was assembled Jul 25, 2026, 10:02 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)