Industrial property report

2760 Red Lion Rd

1 story1,015,495 sqftI1built 2001

Property at a glanceIndustrial building

Ponte Gadea Compass LLC

2026 assessment
$99M OPA value, not a listing price
2027 published assessment
$112M Future roll, not the current tax bill
Neighborhood area
Parkwood · Far Northeast Approximate · based on ZIP 19154
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $111,704,400. It is not yet the billed-year tax basis.

$0$100M$200M$112M2009201220152018202120242027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record91 events · exact dates, newest first
  1. PermitAddition and/or Alteration
  2. PermitAddition and/or Alteration
  3. PermitAddition and/or Alteration
  4. InspectionL&I investigation
  5. L&I violationPERIODIC TESTING
  6. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  7. InspectionL&I investigation
  8. PermitAlterations
  9. PermitAddition and/or Alteration
  10. PermitAddition and/or Alteration
  11. PermitAddition and/or Alterations
  12. PermitAddition and/or Alteration
  13. PermitAddition and/or Alterations
  14. PermitAddition and/or Alteration
  15. CertificationSprinkler Certification
  16. PermitAddition and/or Alteration
  17. CertificationFire Alarm Certification
  18. CertificationFire Alarm Certification
  19. PermitAddition and/or Alteration
  20. PermitAddition and/or Alteration
  21. PermitNew construction, addition, GFA change
  22. PermitAddition and/or Alterations
  23. PermitAddition and/or Alterations
  24. PermitAddition and/or Alterations
  25. PermitAlterations
  26. PermitAddition and/or Alteration
  27. PermitAddition and/or Alteration
  28. PermitNew construction, addition, GFA change
  29. PermitAddition and/or Alteration
  30. PermitAddition and/or Alterations
  31. PermitAddition and/or Alteration
  32. PermitAddition and/or Alterations
  33. PermitAddition and/or Alterations
  34. PermitAlterations
  35. PermitAddition and/or Alteration
  36. PermitAddition and/or Alterations
  37. PermitAddition and/or Alteration
  38. CertificationSprinkler Certification
  39. PermitAddition and/or Alteration
  40. PermitNew construction, addition, GFA change
  41. PermitAddition and/or Alteration
  42. AppealLIRB Violation Appeal
  43. PermitAddition and/or Alteration
  44. PermitNew construction, addition, GFA change
  45. CertificationSprinkler Certification
  46. CertificationSprinkler Certification
  47. CertificationFire Alarm Certification
  48. CertificationFire Alarm Certification
  49. PermitAddition and/or Alteration
  50. PermitAddition and/or Alterations
  51. PermitAlterations
  52. PermitAddition and/or Alterations
  53. PermitAddition and/or Alteration
  54. PermitNew construction, addition, GFA change
  55. PermitAddition and/or Alteration
  56. PermitAddition and/or Alteration
  57. PermitAddition and/or Alterations
  58. PermitSuppression
  59. PermitUse
  60. PermitZoning/use
  61. PermitSign
  62. PermitPlumbing
  63. PermitSuppression
  64. PermitUse
  65. PermitNew construction
  66. PermitOperations
  67. PermitElectrical
  68. PermitOperations
  69. L&I violationPERMB- WK DONE W/O NOTIFY INSP
  70. PermitSuppression
  71. PermitMajor alteration
  72. PermitSuppression
  73. PermitOperations
  74. PermitOperations
  75. PermitOperations
  76. PermitSuppression
  77. PermitElectrical
  78. PermitElectrical
  79. PermitMajor alteration
  80. PermitSuppression
  81. PermitElectrical
  82. PermitElectrical
  83. PermitSuppression
  84. PermitMajor alteration
  85. PermitZoning/use
  86. PermitOperations
  87. AppealBuilding standards appeal
  88. PermitOperations
  89. LicenseNBC PHILADELPHIA MERCHANTS INC: Dumpster License - Private Property L&I license filing initially issued
  90. PermitElectrical
  91. PermitOperations

Verify the public record

$1,380,553/year estimated property tax

2026 taxable assessment $98,625,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $111,704,400. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 884288400
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources Record found

$951,046.42 was recorded for this parcel in Philadelphia's June 2022 delinquency snapshot for 2020–2021. That amount may have been paid, reduced, or increased since; it is not a current payoff figure.

$855,504.51 principal$27,954.59 interest$31,948.11 penalty$35,639.21 other charges
2years recorded 2020–2021tax periods Noactionable flag Nopayment agreement Nobankruptcy flag Yesassessment appeal

The snapshot’s 2022 context used $85,000,000 total assessment, $85,000,000 taxable, and $0 exempt/abated. Those historical fields can differ from today’s OPA exemption status.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Industrial property

Industrial building, recorded in the City's industrial category. The public record and owner trail follow.

$951K · Jun 2022 delinquency snapshot

What it is
Industrial building Ind Warehouse Masonry+Oth
Owner
Ponte Gadea Compass LLC
$ / sq ft
$110 above the $70 median for 3,574 industrial parcels citywide
Interior area
1,015,495 sqft
Lot size
3,071,493 sqft
Stories
1
Built
2001
Zoning
I1

Recorded owner

Who's behind it

Ponte Gadea Compass LLC · corporate / LLC owner

• Tax bills mail to 200 South Biscayne Boulevard Sute 3250, Miami FL, 33131 — outside Philadelphia

Block context

2700 block of Red Lion Rd. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 2750 Red Lion Rd  ·  2770 Red Lion Rd

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 91 dated rows
  1. PermitAddition and/or Alteration

    Permit EP-2026-004926 · Issued

    Power feeders & lighting installation for a new conveyor system. 100A power feeders at 2 locations. Wiring for area lighting ***ALL WORK PER APPROVED PLANS***

  2. PermitAddition and/or Alteration

    Permit CP-2026-003648 · Issued

    FOR INSTALLATION OF CONVEYOR AS PER APPROVED PLANS.

  3. PermitAddition and/or Alteration

    Permit EP-2026-004955 · Issued

    Installation of 6 replacement pad-mounted transformers (5 - 1500kVA & 1 - 750kVA) . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  4. InvestigationL&I investigation

    Case CF-2026-015102 · PASSED

    The cited inspection visit was marked passed.

  5. ViolationPERIODIC TESTING

    Case CF-2026-015102 · Violation VI-2026-009634 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  6. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2026-015102 · Violation VI-2026-009635 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  7. InvestigationL&I investigation

    Case CF-2026-015102 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  8. PermitAlterations

    Permit PP-2025-012789 · Completed

    Pull (28) WC/Urinals and replace in same locations. Replace (6) lavs with new piping. Replace (4) Floor Drains and (1) Mop Sink in same locations with no new piping. (4) Floor Drains (6) Lavs Rough In of aboveground piping (28) Water Closet/Urinals (1) Mop Sink - OTHER

  9. PermitAddition and/or Alteration

    Permit EP-2025-009448 · Completed

    INSTALL 23 RELAY MODULES FOR HVLS FANS SHUTDOWNS. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA AND PER PLANS.

  10. PermitAddition and/or Alteration

    Permit EP-2025-007858 · Completed

    Install 23 High Velocity fans in warehouse area . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **SEPARATE FIRE ALARM PERMIT WILL BE REQ'D FOR THE FIRE ALARM WORK**

  11. PermitAddition and/or Alterations

    Permit FP-2025-002053 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (15) sprinkler heads to accommodate toilet room renovation

  12. PermitAddition and/or Alteration

    Permit EP-2025-009434 · Completed

    INSTALL LIGHTING FIXTURES, LIGHTING CONTROL, GFCI RECEPTACLE OUTLETS AND REPLACE FIRE ALARM DEVICES TO RESTROOM AREA. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC.

  13. PermitAddition and/or Alterations

    Permit MP-2025-005134 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Replace (8) exhaust grilles

  14. PermitAddition and/or Alteration

    Permit CP-2025-003739 · Completed

    FOR RENOVATION WORK TO EXISTING TOILET ROOMS OF AN EXISTING WAREHOUSE FACILITY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/ FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  15. CertificationSprinkler Certification

    Certification BC-2026-004759 · Certified

    Expires 2026-09-24

  16. PermitAddition and/or Alteration

    Permit EP-2025-007724 · Completed

    New lighting and receptacles on mezzanine platform . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  17. CertificationFire Alarm Certification

    Certification BC-2025-026922 · Deficient

  18. CertificationFire Alarm Certification

    Certification BC-2025-028839 · Certified

    Expires 2026-09-16

  19. PermitAddition and/or Alteration

    Permit EP-2025-002872 · Issued

    Remove old conveyor and install new conveyor using existing circuits as per 2017 NEC.

  20. PermitAddition and/or Alteration

    Permit EP-2025-008069 · Completed

    Install dual input monitor module for high bay platform sprinklers as per 2016 NFPA 72.

  21. PermitNew construction, addition, GFA change

    Permit ZP-2025-002279 · Issued

    For site work and landscaping to create a private driveway for vehicular access through 9901 E. Roosevelt Blvd to the public right-of-way (Bluegrass Rd). No new parking is included with this permit.

  22. PermitAddition and/or Alterations

    Permit FP-2025-001000 · Issued

    FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO BE TIED INTO AN EXISTING SYSTEM AS PER APPROVED PLANS. **ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.**

  23. PermitAddition and/or Alterations

    Permit FP-2025-000977 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (22) sprinkler heads to accommodate interior alterations to break room area

  24. PermitAddition and/or Alterations

    Permit MP-2025-001111 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2024-006425

  25. PermitAlterations

    Permit PP-2025-002244 · Completed

    Plumbing Permit (Interior) for combo CP-2024-006425

  26. PermitAddition and/or Alteration

    Permit EP-2025-001578 · Completed

    Electrical Permit for combo CP-2024-006425

  27. PermitAddition and/or Alteration

    Permit CP-2025-000095 · Issued

    FOR LEVEL II INTERIOR ALTERATIONS TO ERECT A MEZZANINE PLATFORM WITHIN AN EXISTING GROUP S-1 WAREHOUSE. EXISTING BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE ZP-2025-000590 FOR ZONING APPROVAL OF G.F.A. / F.A.R. INCREASE.

  28. PermitNew construction, addition, GFA change

    Permit ZP-2025-000590 · Issued

    FOR THE ERECTION OF A MEZZANINE AND PLATFORM IN AN EXISTING WAREHOUSE WITH ALL OTHER USES IN THE SAME STRUCTURE AS PREVIOUSLY APPROVED; SIZE AND LOCATION AS SHOWN IN THE PLAN.

  29. PermitAddition and/or Alteration

    Permit CP-2024-006425 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION.

  30. PermitAddition and/or Alterations

    Permit MP-2025-001558 · Issued

    FOR THE INSTALLATION OF CONVEYOR LINE AS PER PLAN AND MANUFACTURE SPECIFICATION.

  31. PermitAddition and/or Alteration

    Permit EP-2025-000538 · Completed

    Adding 2 receptacles and 2 lights to security canopy

  32. PermitAddition and/or Alterations

    Permit FP-2025-000011 · Issued

    FOR THE EXTENSION OF AN EXISTING FIRE SPRINKLER SYSTEM PER APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13.

  33. PermitAddition and/or Alterations

    Permit FP-2024-002372 · Completed

    FOR AN ALTERATION TO AN EXISTING SPRINKLER SYSTEM. WORK TO INCLIUDE THE INSTALLATION OF NEW SPRINKLER HEADS TO BE LINKED TO THE EXISTING SYSTEM PER APPROVED PLANS.** ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.**

  34. PermitAlterations

    Permit PP-2024-011808 · Completed

    Plumbing Permit (Interior) for combo CP-2024-003317

  35. PermitAddition and/or Alteration

    Permit EP-2024-008315 · Completed

    Install (1) 60 amp disconnect, (1) 30kva transformer, (1) 100 amp MCB panel, lighting, receptacles, power to equipment, and exit/emergency lights as per 2017 NEC.

  36. PermitAddition and/or Alterations

    Permit MP-2024-003911 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2024-003317

  37. PermitAddition and/or Alteration

    Permit CP-2024-003317 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CREATE NEW BATHROOM AREAS WITHIN AN EXISTING WAREHOUSE BUILDING AS PER APPROVED PLANS. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP WORK**

  38. CertificationSprinkler Certification

    Certification BC-2024-026953 · Certified

    Expires 2025-09-13

  39. PermitAddition and/or Alteration

    Permit CP-2024-002169 · Issued

    FOR ERECTION OF CANOPY ADDITION AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MEP WORK.

  40. PermitNew construction, addition, GFA change

    Permit ZP-2024-004860 · Issued

    FOR THE ERECTION OF AN ADDITION AT THE FRONT OF EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN PLAN.

  41. PermitAddition and/or Alteration

    Permit EP-2023-009587 · Completed

    Electrical Permit for combo CP-2023-005142

  42. AppealLIRB Violation Appeal

    Appeal HA-2022-004854 · Closed · Complete

    See Attached

  43. PermitAddition and/or Alteration

    Permit CP-2023-005142 · Completed

    FOR THE ERECTION OF CONVEYOR SYSTEM AS PER APPROVED PLANS.

  44. PermitNew construction, addition, GFA change

    Permit ZP-2023-007006 · Issued

    FOR IMPROVEMENTS TO THE EXISTING DRIVEWAY. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS.

  45. CertificationSprinkler Certification

    Certification BC-2024-003321 · Certified

    Expires 2024-10-27

  46. CertificationSprinkler Certification

    Certification BC-2024-001939 · Deficient

  47. CertificationFire Alarm Certification

    Certification BC-2023-023380 · Certified

    Expires 2024-10-26

  48. CertificationFire Alarm Certification

    Certification BC-2022-011817 · Certified

    Expires 2023-08-17

  49. PermitAddition and/or Alteration

    Permit EP-2022-002264 · Completed

    Electrical Permit for combo CP-2021-005184

  50. PermitAddition and/or Alterations

    Permit MP-2022-001330 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2021-005184

  51. PermitAlterations

    Permit PP-2022-003417 · Completed

    Plumbing Permit (Interior) for combo CP-2021-005184

  52. PermitAddition and/or Alterations

    Permit FP-2022-000858 · Completed

    Modifying 82 Sprinklers See CP-2021-005184

  53. PermitAddition and/or Alteration

    Permit CP-2021-005184 · Completed

    FOR A TWO-STORY ADDITION TO AN EXISTING WAREHOUSE AND OFFICE SPACE, AS PER APPROVED PLANS.

  54. PermitNew construction, addition, GFA change

    Permit ZP-2021-005233 · Completed

    FOR THE ERECTION OF TWO(2) STORY ADDITION OF AN EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN IN THE APPLICATION.

  55. PermitAddition and/or Alteration

    Permit CP-2020-003863 · Completed

    FOR THE ERECTION OF CONCRETE PAD FOR PROPOSED GENERATORS AND SWITCHGEAR AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MEP WORK.

  56. PermitAddition and/or Alteration

    Permit EP-2020-008616 · Completed

    FOR THE ERECTION OF CONCRETE PAD FOR PROPOSED GENERATORS AND SWITCHGEAR AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MEP WORK.

  57. PermitAddition and/or Alterations

    Permit MP-2020-004634 · Completed

    FOR THE ERECTION OF CONCRETE PAD FOR PROPOSED GENERATORS AND SWITCHGEAR AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MEP WORK.

  58. PermitSuppression

    Permit 1005085 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  59. PermitUse

    Permit 986193 · COMPLETED

    FOR THE RECONFIGURATION OF OF EXISTING ACCESSORY PARKING SPACES TO A 783 SPACES INCLUDING SIXTEEN(!6) ACCESSIBLE SPACES INCLUDING WITH THREE(3) VAN ACCESSIBLE SPACES;WITH 134 LOADING SPACES, WITH 514 TRAILER SPACES AND EIGHT(8)BICYCLE SPACES AS PART OF AN EXISTING PARKING LOT AS PREVIOUSLY APPROVED ALL ACCESSORY TO EXISTING WAREHOUSE AND BUSINESS AND PROFESSIONAL OFFICE SPACE AS PREVIOUSLY APPROVED. (SIZE AND LOCATION AS SHOWN IN THE APPLICATION).

  60. PermitZoning/use

    Permit 970652 · COMPLETED

    FOR ERECTION OF ONE NON ILLUMINATED WALL SIGN (FCO LETTERS) ON BUILDING FACADE (21" X 106" = 15.45 SF). SIZE AND LOCATION AS SHOWN ON THE APPLICATION. USES: FOR SIGN ACCESSORY TO EXISTING WAREHOUSE AND BUSINESS AND PROFESSIONAL OFFICE AS PREVIOUSLY APPROVED.

  61. PermitSign

    Permit 970656 · COMPLETED

    FOR ERECTION OF ONE NON ILLUMINATED WALL SIGN (FCO LETTERS) ON BUILDING FACADE (21" X 106" = 15.45 SF).SEE PLAN, FOR DETAILS.ALL ANCHORAGES TO BE THREADED BOLTS WITH LOCK WASHERS WITH POSITIVE ANCHORAGE TO METAL STUD STOREFRONT PER PLANS - ALL HARDWARE SHALL BE SIZED TO SUPPORT WEIGHT OF INSTALLED LETTERS / SIGN COMPONENTS. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL WORK.

  62. PermitPlumbing

    Permit 953909 · COMPLETED

    NEW CONSTRUCTION: EXTERIOR PLUMBING; STORMWATER MANAGEMENT SYSTEM; 1 PRECAST CONCRETE OUTLET CONTROL STRUCTURE WITHIN EXISTING STORMWATER MANAGEMENT BASIN.INSTALL 87LF OF 4" PERFORATED PIPING WITH BASIN AND CONNECT TO OUTLET STRUCTURE PER 2004 PHILADELPHIA PLUMBING CODE(WAREHOUSE)

  63. PermitSuppression

    Permit 936336 · COMPLETED

    MODIFY (35) SPRINKLER AND TIE-IN TO EXITING 6" MAIN WITH NEW 6"X3" MECHANICAL TEE TO FEED NEW LAYOUT IN NEW OFFICES, IN MARSHALLS DISTRIBUTION CENTER FOR THE NEW MODULAR TICKET OFFICE, AS PER PLANS, CALCS& CUT SHEETS.

  64. PermitUse

    Permit 926150 · COMPLETED

    FOR THE REDUCTION OF EXISTING ACCESSORY PARKING SPACES FROM 1,200 SPACES TO A 798 SPACES INCLUDING WITH TWENTY-FOUR(24) ACCESSIBLE SPACES INCLUDING WITH THREE(3) VAN ACCESSIBLE SPACES;INCREASE TRAILER SPACES FROM 483 SPACES TO A 586 SPACES, EXISTING SIXTY(60) LOADING SPACES AND EIGHT(8)BICYCLE SPACES AS PART OF AN EXISTING PARKING LOT AS PREVIOUSLY APPROVED ALL ACCESSORY TO EXISTING WAREHOUSE AND BUSINESS AND PROFESSIONAL OFFICE SPACE AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION. SIZE AND LOCATION AS SHOWN IN THE APPLICATION.

  65. PermitNew construction

    Permit 929474 · COMPLETED

    FOR EARTH DISTURBANCE AND PARKING LOT STPRINING TO ADJUST PARKING SPACE ARRANGEMENT IN ACCORDANCE WITH APPROVED PLANS. SEPARATE PERMIT REQ'D FOR ANY ELECTRICAL WORK.

  66. PermitOperations

    Permit 25645 · COMPLETED

    07/27/18 ERECT TENT 20X40

  67. PermitElectrical

    Permit 790097 · COMPLETED

    ELECTRICAL WIRING FOR NEW CONVEYOR SYSTEM AS PER NEC 2008 (EAST DISTRICT)

  68. PermitOperations

    Permit 25015 · COMPLETED

    7/25/17 ERECT ASSEMBLY TENT 20X40

  69. ViolationPERMB- WK DONE W/O NOTIFY INSP

    Case 773184 · Violation 4394431 · Code A-302.11/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  70. PermitSuppression

    Permit 792532 · COMPLETED

    INSTALLATION OF (175) SPRINKLER HEADS ON THE MEZZANINE LEVEL OF THE SORTER PLATFORM AS PER THE SUBMITTED PLANS AND CALCS.** FEED FROM EXISTING FIRE SUPPRESSION SYSTEM **

  71. PermitMajor alteration

    Permit 773184 · COMPLETED

    INSTALLING MATERIAL HANDLING EQUIPMENT PLAYFORM & CONVEYOR INTERNAL TO WAREHOUSE BUILDING. SEPARATE PERMIT REQ'D FOR ANY ELECTRICAL WORK.

  72. PermitSuppression

    Permit 732499 · COMPLETED

    RELOCATE 6 SPRINKLES GROUND FLOOR

  73. PermitOperations

    Permit 24091 · COMPLETED

    7/20/16 ERECT ASSEMBLY TENT 20X40

  74. PermitOperations

    Permit 23859 · COMPLETED

    7/29/2015 ERECT ASSEMBLY TENT (20'X40') AT MARSHALLS DISTRICT CENTER - COMPANY PICNIC

  75. PermitOperations

    Permit 23027 · COMPLETED

    08/06/2014 ERECT ASSEMBLY TENT (20'X40') MARSHALS DISTRIBUTION COMPANY PICINIC

  76. PermitSuppression

    Permit 513134 · COMPLETED

    INSTALLATION OF ADDITIONAL SPRINKLERS, LINES IN SORTER AREA AS PER PLANS AND CALCS. TIE INTO EXISTING SYSTEM.

  77. PermitElectrical

    Permit 493835 · COMPLETED

    MISCELLANEOUS POWER AND CONTROL WIRING, FOR THE EXPANSION OF AN EXISTING MATERIAL SORTER & CHUTE IN AN EXISTING WAREHOUSE AS PER 2008 NEC(WAREHOUSE)

  78. PermitElectrical

    Permit 495826 · COMPLETED

    INSTALL REQUIRED INITIATING DIVICES & INDIRECTING DEVICES AT LOC SHOWN ON DRAWING, ADD'L FIRE ALARM DEVICES ARE REQUIRED BECAUSE OF THE NEW MEZZANINE LEVEL AS PER NEC 2008 & NFPA 72 (RETAIL WAREHOUSE)

  79. PermitMajor alteration

    Permit 474015 · COMPLETED

    FOR THE EXPANSION OF AN EXISTING MATERIAL SORTER AND CHUTE IN AN EXISTING WAREHOUSE.

  80. PermitSuppression

    Permit 454572 · COMPLETED

    INSTALLATION OF TWO (2) ADDITIONAL HEADS TO EXTERIOR TRASH COMPACTOR IN ACCORDANCE WITH NFPA 13 AS PER APPROVED DRAWINGS.

  81. PermitElectrical

    Permit 456932 · COMPLETED

    INSTALL ELECTRICAL WORK FOR NEW BACK UP GENERATOR PER 2008 NEC (COMMERCIAL)

  82. PermitElectrical

    Permit 450144 · COMPLETED

    INSTALL RECEPTACLES AND LIGHTING FOR EXPANSION OF MEZZANINE LEVEL AT TJX DISTRIBUTION CENTER PER 2008 NEC (COMMERCIAL)

  83. PermitSuppression

    Permit 439770 · COMPLETED

    INSTALLATION OF NEW SPRINKLERS, NEW PIPING - EXTENSION OF EXISTING SYSTEM FOR NEW MEZZANINE AREA. CONNECTED TO EXISTING FIRE SUPPRESSION SYSTEM W/ EXTG PUMP, FDC.

  84. PermitMajor alteration

    Permit 441682 · COMPLETED

    INSTALLATION OF MEZZANINE SPACE IN THE EXISTING WAREHOUSE AS PER PLANS AND BBS VARIANCE #18254 - ADDITIONAL PERMITS ARE REQUIRED FOR ELECTRICAL AND SUPPRESSION. BUILDING TO BE FULLY SPRINKLERED.

  85. PermitZoning/use

    Permit 438336 · COMPLETED

    INSTALLATION OF MEZZANINE SPACE IN UPPER AREA OF EXISTING WAREHOUSE. WILL INCLUDE BICYCLE PARKING FOR (8) BIKES.

  86. PermitOperations

    Permit 21765 · COMPLETED

    08/01/2012 ERECT ONE (1) ASSEMBLY USE TENT MARSHALLS DISTRIBUTION 20'X40'

  87. AppealBuilding standards appeal

    Appeal 18254 · CLOSED · APPROVED

    Related permit 406402 · ON 5/30/12 DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED NOTICE OF REFUSAL FOR APPLICATION #406402.

  88. PermitOperations

    Permit 20628 · COMPLETED

    8/11/10-ERECTION OF (1)-ASSEMBLY USE TENT

  89. License issue eventNBC PHILADELPHIA MERCHANTS INC: Dumpster License - Private Property L&I license filing initially issued

    License 510171 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  90. PermitElectrical

    Permit 266023 · COMPLETED

    INSTALLATION OF NEW POLE LIGHT FIXTURE.

  91. PermitOperations

    Permit 19771 · COMPLETED

    7/22/09 - ERECTION OF (1) 20X40 ASSEMBLY USE TENT FO COMPANY PICNIC

Where this comes from

Methodology & freshness

This report was assembled Jul 28, 2026, 1:10 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)