Property report

302-12 N 13th St

4 stories29,704 sqftCMX4built 1960

Property at a glanceApartment building

Sunday Breakfast Association Of Philadel

2026 assessment
$3.5M OPA value, not a listing price
2027 published assessment
$4.0M Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $4,034,300. It is not yet the billed-year tax basis.

$0$2.5M$5.0M$4.0M2006201020142018202220262027
Property assessmentAssessmentL&I violationPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record75 events · exact dates, newest first
  1. PermitSign
  2. PermitAddition and/or Alteration
  3. CertificationFire Alarm Certification
  4. CertificationSprinkler Certification
  5. PermitAddition and/or Alteration
  6. PermitAlterations
  7. PermitAddition and/or Alterations
  8. PermitAddition and/or Alterations
  9. PermitAddition and/or Alteration
  10. PermitLot Line Relocation
  11. CertificationSprinkler Certification
  12. CertificationFire Alarm Certification
  13. CertificationSpecial Hazards Certification
  14. CertificationSpecial Hazards Certification
  15. CertificationSprinkler Certification
  16. CertificationFire Alarm Certification
  17. PermitCombined Lot Line Relocation and New Dev…
  18. InspectionL&I investigation
  19. InspectionL&I investigation
  20. InspectionL&I investigation
  21. CertificationSprinkler Certification
  22. InspectionL&I investigation
  23. L&I violationDOOR OPERATION
  24. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  25. L&I violationPERIODIC TESTING
  26. L&I violationFDC SIGNAGE REQUIRED
  27. L&I violationFIRE RESISTANCE RATED CONSTRUCTION
  28. L&I violationFIRE EXTINGUISHERS
  29. CertificationSpecial Hazards Certification
  30. PermitAlterations
  31. CertificationSpecial Hazards Certification
  32. CertificationStandpipe Certification
  33. InspectionL&I investigation
  34. CertificationSpecial Hazards Certification
  35. InspectionL&I investigation
  36. L&I violationFIRE SYSTEMS MAINTAINED
  37. CertificationSpecial Hazards Certification
  38. PermitAlterations
  39. PermitAddition and/or Alterations
  40. PermitAddition and/or Alteration
  41. PermitAddition and/or Alterations
  42. PermitAddition and/or Alteration
  43. InspectionCI INSP
  44. L&I violationMAINTENANCE OF EXITS/LIGHTING
  45. L&I violationFIREBLOCKING/DRAFTSTOPPING
  46. L&I violationRENEW LIC INDICATED
  47. L&I violationSHELTER-IN-PLACE PLAN REQUIRED
  48. L&I violationEXIT DOORS SELF CLOSING/LATCHI
  49. L&I violationEXIT SIGN ILLUMINATION
  50. L&I violationSHELTER PLAN TRAINING AND DRIL
  51. L&I violationMEANS OF EGRESS OBSTRUCTION
  52. L&I violationMEANS OF EGRESS ILLUMINATION
  53. InspectionCI INSP
  54. PermitZoning
  55. PermitElectrical
  56. PermitMajor alteration
  57. PermitZoning/use
  58. InspectionHC SHELTER
  59. InspectionHC SHELTER
  60. L&I violationEVAC DRILL-GRP I1-# PER YR
  61. L&I violationFIRE/EVAC PLN-GRP I1-REQ¿D
  62. InspectionHC SHELTER
  63. PermitElectrical
  64. PermitElectrical
  65. PermitSuppression
  66. PermitElectrical
  67. PermitMajor alteration
  68. PermitMechanical
  69. PermitSuppression
  70. PermitPlumbing
  71. PermitMajor alteration
  72. PermitMajor alteration
  73. PermitPlumbing
  74. InspectionCSUINITIAL
  75. InspectionCSUINITIAL

Verify the public record

$3,765/year estimated property tax

2026 taxable assessment $269,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $4,034,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881519510
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $269,000 of $3,500,000 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Apartment building, recorded in the City's multi-family category. The public record and owner trail follow.

What it is
Apartment building Apt Boarding Home Masonry
Owner
Sunday Breakfast Association Of Philadel
$ / sq ft
$136 assessed value ÷ interior sqft
Corridor
Callowhill East city commercial corridor
Interior area
29,704 sqft
Lot size
7,399 sqft
Stories
4
Built
1960
Zoning
CMX4

Recorded owner

Who's behind it

Sunday Breakfast Association Of Philadel · corporate / LLC owner

• Tax bills mail to 302-12 N 13th St, Philadelphia PA, 19107

Block context

300 block of N 13th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 314-22 N 13th St  ·  324 N 13th St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 75 dated rows
  1. PermitSign

    Permit GP-2026-001762 · Issued

    For the Installation of one metal awning on building facade 11' x 12'. As per approved plans.

  2. PermitAddition and/or Alteration

    Permit EP-2026-000152 · Completed

    Installation and Relocation of Fire Alarm Devices on existing Fire Alarm. All work per approved plans

  3. CertificationFire Alarm Certification

    Certification BC-2026-002330 · Certified

    Expires 2027-01-12

  4. CertificationSprinkler Certification

    Certification BC-2026-002331 · Certified

    Expires 2027-01-12

  5. PermitAddition and/or Alteration

    Permit EP-2025-008256 · Completed

    Partial building fit-out, per submitted plans, to include partial demo; installation of lighting fixtures/controls; branch power; mechanical hook-ups; and service panel/tie-in. ***NO FIRE ALARM***

  6. PermitAlterations

    Permit PP-2025-011005 · Issued

    INSTALLATION OF 6 FIXTURES WITH ALL ASSOCIATED PIPING IN STRICT COMPLIANCE WITH 2018 PPC. ADDITIONAL FIXTURES OR DEVIATION OF THIS APPROVED SCOPE SHALL REQUIRE SUBMISSION OF PLANS AND A PLAN REVIEW BE PERFORMED. Need to add (1) additional fixture - Utility sink Would be 7 total fixtures after the addition

  7. PermitAddition and/or Alterations

    Permit FP-2025-001763 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (82) sprinklers to accommodate interior alterations

  8. PermitAddition and/or Alterations

    Permit MP-2025-004230 · Issued

    Alteration to the existing HVAC system to serve new floor layout as per approved plans. Amendment to include details of the installation of the ERV unit.

  9. PermitAddition and/or Alteration

    Permit CP-2025-000688 · Issued

    FOR A LEVEL II INTERIOR ALTERATIONS TO A PORTION OF THE 1ST AND 2ND FLOOR LEVEL OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE SELECTIVE DEMOLITION AND THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS THROUGHOUT. **STRUCTURAL WORK TO BE INCLUDED IN THE SCOPE OF WORK**BUILDING IS FULLY SPRINKLERED. ** ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**ASBESTOS REMEDIATION REQUIRED PRIOR TO START OF WORK**

  10. PermitLot Line Relocation

    Permit ZP-2025-002033 · Issued

    FOR A LOT ADJUSTMENT (CONSOLIDATION) TO CREATE TWO (2) LOTS [PROPOSED "LOT 1" AND "LOT 2") WITH EASEMENTS FROM THREE (3) EXISTING LOTS [302-12 N 13TH ST, 1310 PEARL ST, AND 303 N BROAD ST]. SIZES AND LOCATIONS AS SHOWN ON PLANS.

  11. CertificationSprinkler Certification

    Certification BC-2025-005060 · Certified

    Expires 2026-02-10

  12. CertificationFire Alarm Certification

    Certification BC-2025-005061 · Certified

    Expires 2026-02-10

  13. CertificationSpecial Hazards Certification

    Certification BC-2025-003024 · Certified

    Expires 2026-01-31

  14. CertificationSpecial Hazards Certification

    Certification BC-2024-021835 · Certified

    Expires 2025-07-31

  15. CertificationSprinkler Certification

    Certification BC-2024-005821 · Certified

    Expires 2025-02-28

  16. CertificationFire Alarm Certification

    Certification BC-2024-005820 · Certified

    Expires 2025-02-28

  17. PermitCombined Lot Line Relocation and New Dev…

    Permit ZP-2022-006963 · Issued

    FOR THE RELOCATION OF LOT LINES TO CREATE TWO (2) LOTS (PROPOSED LOT 1 AND PROPOSED LOT 2) FROM EXISTING THREE DEEDED LOTS (302-12 N 13TH ST, 1310 PEARL ST AND 303 N BROAD ST/ 7 OPA ACCOUNTS- 302-12 N 13TH ST, 1310 PEARL ST, 303 N BROAD ST, 1341 VINE ST, 1319-39 VINE ST, 1315-17 VINE ST AND 1313 VINE ST).

  18. InvestigationL&I investigation

    Case CF-2022-126889 · PASSED

    The cited inspection visit was marked passed.

  19. InvestigationL&I investigation

    Case CF-2022-126889 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  20. InvestigationL&I investigation

    Case CF-2022-126889 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  21. CertificationSprinkler Certification

    Certification BC-2023-003950 · Certified

    Expires 2024-02-21

  22. InvestigationL&I investigation

    Case CF-2022-126889 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  23. ViolationDOOR OPERATION

    Case CF-2022-126889 · Violation VI-2022-095776 · Code F-705.2.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  24. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2022-126889 · Violation VI-2022-095772 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  25. ViolationPERIODIC TESTING

    Case CF-2022-126889 · Violation VI-2022-095771 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  26. ViolationFDC SIGNAGE REQUIRED

    Case CF-2022-126889 · Violation VI-2022-095778 · Code F-912.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  27. ViolationFIRE RESISTANCE RATED CONSTRUCTION

    Case CF-2022-126889 · Violation VI-2022-095777 · Code F-701.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. ViolationFIRE EXTINGUISHERS

    Case CF-2022-126889 · Violation VI-2022-095774 · Code F-906.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. CertificationSpecial Hazards Certification

    Certification BC-2022-011077 · Certified

    Expires 2023-08-11

  30. PermitAlterations

    Permit PP-2022-002139 · Expired

    Curb trap, fresh air inlet

  31. CertificationSpecial Hazards Certification

    Certification BC-2022-001572 · Certified

    Expires 2023-02-08

  32. CertificationStandpipe Certification

    Certification BC-2021-007503 · Certified

    Expires 2022-12-02

  33. InvestigationL&I investigation

    Case CF-2021-083587 · PASSED

    The cited inspection visit was marked passed.

  34. CertificationSpecial Hazards Certification

    Certification BC-2021-004215 · Certified

    Expires 2022-09-17

  35. InvestigationL&I investigation

    Case CF-2021-083587 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  36. ViolationFIRE SYSTEMS MAINTAINED

    Case CF-2021-083587 · Violation VI-2021-060290 · Code FC-13-901.6 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  37. CertificationSpecial Hazards Certification

    Certification BC-2021-003232 · Deficient

  38. PermitAlterations

    Permit PP-2021-006866 · Expired

    Remove and replace 3 existing floor drains with new. Remove and replace shower trim (control handles) in Shower Room. CP-2020-005870

  39. PermitAddition and/or Alterations

    Permit MP-2021-000451 · Expired

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For Mechanical Work to include the installation as per attached standards. Deviations from these standards require submission of construction and site plans.

  40. PermitAddition and/or Alteration

    Permit EP-2021-000229 · Completed

    Replace existing area lighting with new. Change switching from toggle to occupancy sensor. Replace existing duplex receptacles in space with GFCI receptacles as per 2017 nec

  41. PermitAddition and/or Alterations

    Permit FP-2020-002491 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (7) sprinklers heads at 3rd floor Sunday Breakfast Restrooms. ( CP-2020-005870 )

  42. PermitAddition and/or Alteration

    Permit CP-2020-005870 · Expired

    FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, DOORS, FIXTIRES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL MEP AND FIRE SUPPRESSION WORK. **ASBESTOS ABATEMENT REQUIRED PRIOR TO START OF WORK.**

  43. InvestigationCI INSP

    Case 649801 · PASSED

    The cited inspection visit was marked passed.

  44. ViolationMAINTENANCE OF EXITS/LIGHTING

    Case 649801 · Violation 4778248 · Code FC-13-1016.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  45. ViolationFIREBLOCKING/DRAFTSTOPPING

    Case 649801 · Violation 4778249 · Code FC-13-703.11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  46. ViolationRENEW LIC INDICATED

    Case 649801 · Violation 4778251 · Code LR-1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  47. ViolationSHELTER-IN-PLACE PLAN REQUIRED

    Case 649801 · Violation 4778261 · Code FC-13-404.33 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  48. ViolationEXIT DOORS SELF CLOSING/LATCHI

    Case 649801 · Violation 4778247 · Code FC-13-100825 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  49. ViolationEXIT SIGN ILLUMINATION

    Case 649801 · Violation 4778246 · Code FC-13-1007.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  50. ViolationSHELTER PLAN TRAINING AND DRIL

    Case 649801 · Violation 4778269 · Code FC-13-404332 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  51. ViolationMEANS OF EGRESS OBSTRUCTION

    Case 649801 · Violation 4778244 · Code FC-13-1003.3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  52. ViolationMEANS OF EGRESS ILLUMINATION

    Case 649801 · Violation 4778245 · Code FC-13-1006.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  53. InvestigationCI INSP

    Case 649801 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  54. PermitZoning

    Permit 507673 · COMPLETED

    RELOCATION OF LOT LINE TO CREATE TWO (2) LOTS (LOT #1 & 2) FROM SIX (6) DEEDED LOTS (303 N BROAD ST, 1313, 1315-17, 1319-39 & 1341 VINE ST AND 302-12 N 13TH ST).

  55. PermitElectrical

    Permit 491982 · COMPLETED

    INSTALL CONDUIT FOR NEW TELCO LINE INSTALLED BY OTHERS PER 2008 NEC (SHELTER)

  56. PermitMajor alteration

    Permit 347569 · COMPLETED

    ERECT (3) ANTENNAS, (6) RRH'S AND (4) DISTRIBUTION BOXES, (1) EQUIPMENT CABINET AND (1) EQUIPMENT RACK.

  57. PermitZoning/use

    Permit 342410 · COMPLETED

    ERECT 3 LTE ANTENNAS, 6 RRHS AND 4 DISTRIBUTION BOXES. ERECT 1 EQUIP CABINET AND 1 EQUIP RACK

  58. InvestigationHC SHELTER

    Case 267247 · PASSED

    The cited inspection visit was marked passed.

  59. InvestigationHC SHELTER

    Case 267247 · PASSED

    The cited inspection visit was marked passed.

  60. ViolationEVAC DRILL-GRP I1-# PER YR

    Case 267247 · Violation 2028553 · Code FC-408.5/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  61. ViolationFIRE/EVAC PLN-GRP I1-REQ¿D

    Case 267247 · Violation 2028552 · Code FC-408.5/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  62. InvestigationHC SHELTER

    Case 267247 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  63. PermitElectrical

    Permit 244511 · COMPLETED

    PROVIDE AND INSTALL POWER WIRING FOR FIRE PUMP AS PER 2005 NEC,(CC DISTRICT)

  64. PermitElectrical

    Permit 197750 · COMPLETED

    FIRE ALARM: 1 FACP, 2 REMOTE ANNUCIATORS, 12 DUCT DETECTORS, 2 N.A.C. POWER SUPPLIES, 3 SMOKE DETECTORS, 4 HEAT DETECTORS, 1 FLOW TAMPER, 23 PULL STATIONS, 44 HORN STROBES, 1 ANSUL MODULE, AS PER NFPA-72 )(CC DIST)

  65. PermitSuppression

    Permit 189080 · COMPLETED

    INSTALL NEW WET SPRINKLER SYSTEM, FIRE PUMP AND BACKFLOW PREVENTER. CONVERT EXISTING DRY STANDPIPES TO MANUAL WET STANDPIPES.

  66. PermitElectrical

    Permit 189960 · COMPLETED

    LOAD CENTER AND WIRING FOR NEW COMMERCIAL KITCHEN ONLY . AS PER 2005 NEC (CC DIST)

  67. PermitMajor alteration

    Permit 184253 · COMPLETED

    REPLACEMENT OF ALL 23 WINDOWS AND FRONT ENTRANCE SYSTEM WITH LIKE ALUMINUM WINDOWS. NO CHANGE IN SIZE OR LOCATION AS PER PHOTOS.

  68. PermitMechanical

    Permit 169640 · COMPLETED

    INSTALL DUCTWORK AND MECHANICAL UNITS

  69. PermitSuppression

    Permit 173545 · COMPLETED

    INSTALLATION OF A COMMERCIAL COOKING EXTINGUISHING SYSTEM.

  70. PermitPlumbing

    Permit 171754 · COMPLETED

    FIXTURE INSTALLATION

  71. PermitMajor alteration

    Permit 155885 · COMPLETED

    ALTERATIONS TO INCLUDE THE RELOCATION OF KITCHEN AND DINING SPACE TO FIRST FLOOR.

  72. PermitMajor alteration

    Permit 133068 · COMPLETED

    INTERIOR RENOVATIONS TO STORAGE FACILITY MET.STUD FRAME INTERIOR FACE OF PERIMETER WALLS INSTALLATION OF INSULATION AND DRY WALL.FRAME NEW FLOOR IN RECESSED RAMP AREA TO BRING FLUSH WITH SURROUNDING AREA.

  73. PermitPlumbing

    Permit 62104 · COMPLETED

    INSTALL 2 BRADFORD WHITE MOD# EF100T300E3N WATER HEATERS

  74. InvestigationCSUINITIAL

    Case 59504 · PASSED

    The cited inspection visit was marked passed.

  75. InvestigationCSUINITIAL

    Case 59504 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 30, 2026, 4:36 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.