Property report

313 S 10th St

3 stories7,114 sqftRM1built 1900

Property at a glanceApartment building

Individual owner on record

2026 assessment
$1.4M OPA value, not a listing price
2027 published assessment
$1.4M Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $1,432,800. It is not yet the billed-year tax basis.

$0$1.0M$2.0M$1.4M2004200820122016202020242027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record53 events · exact dates, newest first
  1. CertificationFire Alarm Certification
  2. PermitAddition and/or Alteration
  3. PermitAddition and/or Alteration
  4. CertificationFire Alarm Certification
  5. InspectionL&I investigation
  6. PermitAddition and/or Alteration
  7. AppealLIRB Violation Appeal
  8. InspectionL&I investigation
  9. InspectionL&I investigation
  10. CertificationFire Alarm Certification
  11. PermitAddition and/or Alteration
  12. InspectionL&I investigation
  13. CertificationFire Escape Report
  14. CertificationFire Escape Report
  15. L&I violationRENTAL LICENSE MULTI FAMILY (R2)
  16. InspectionL&I investigation
  17. InspectionL&I investigation
  18. InspectionL&I investigation
  19. L&I violationFIRE ESCAPE REPORT REQUIRED
  20. InspectionL&I investigation
  21. CertificationFire Alarm Certification
  22. LicensePHI ALPHA SIGMA: Rental landlord or residential registration marked inactive
  23. InspectionCSUINITIAL
  24. CertificationFire Escape Report
  25. CertificationFire Escape Report
  26. PermitMajor alteration
  27. InspectionCSUINITIAL
  28. InspectionCI INSP
  29. InspectionCI INSP
  30. InspectionCI INSP
  31. InspectionCI INSP
  32. L&I violationRENEW LIC INDICATED
  33. InspectionCI INSP
  34. InspectionCSUINITIAL
  35. L&I violationEXTERIOR STRUCT UNSAFE COND 11
  36. L&I violationUNSAFE STRUCTURE
  37. InspectionCSUINITIAL
  38. CertificationFire Escape Report
  39. InspectionPRECOURT (likely: pre-court compliance inspection)
  40. InspectionPRECOURT (likely: pre-court compliance inspection)
  41. InspectionPRECOURT (likely: pre-court compliance inspection)
  42. InspectionPRECOURT (likely: pre-court compliance inspection)
  43. InspectionPRECOURT (likely: pre-court compliance inspection)
  44. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  45. L&I violationFIRE-DOOR STAIR 1HR RATING
  46. L&I violationINT DOOR SELF-CLOSE
  47. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  48. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  49. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  50. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  51. L&I violationEGRESS CLEAR OBSTRUCTION
  52. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  53. LicensePHI ALPHA SIGMA: Rental landlord or residential registration initially issued

Verify the public record

$19,037/year estimated property tax

2026 taxable assessment $1,360,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,432,800. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881330200
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Where the record looks off

Conflicts in City paperwork. Flags on the data, not the property.

"Built 1900" is usually a placeholder

Philadelphia records use 1900 as a stand-in when the real construction year was never documented. Treat the age as unknown, not as 120+ years.

Property report

Commercial property

Apartment building, recorded in the City's multi-family category. The public record and owner trail follow.

What it is
Apartment building Apts Dormitory Masonry
Owner
Individual owner on record Individual name redacted
$ / sq ft
$201 assessed value ÷ interior sqft
Interior area
7,114 sqft
Lot size
3,200 sqft
Stories
3
Built
1900
Zoning
RM1

Block context

300 block of S 10th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 311 S 10th St  ·  317 S 10th St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 25, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

PHI ALPHA SIGMAInactive

Rental · Initial issue date Apr 19, 2004 · Terminal license date Apr 29, 2021

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 52 dated rows
  1. CertificationFire Alarm Certification

    Certification BC-2026-004811 · Certified

    Expires 2027-01-15

  2. PermitAddition and/or Alteration

    Permit EP-2025-012130 · Completed

    ***NEC FISHING ONLY*** Kitchen circuits x3 (Countertop receptacles) Fridge circuit x1 2nd floor bedroom rewire - x3 TR receptacles - Lamp smart remote

  3. PermitAddition and/or Alteration

    Permit EP-2025-008755 · Completed

    New circuits x2 New outlets x5 Fishing Only

  4. CertificationFire Alarm Certification

    Certification BC-2025-006115 · Certified

    Expires 2026-01-13

  5. InvestigationL&I investigation

    Case CF-2023-009782 · PASSED

    The cited inspection visit was marked passed.

  6. PermitAddition and/or Alteration

    Permit EP-2024-007233 · Completed

    120 Volt 2000 W 360 Degrees Occupancy Sensor x2 Exit Sign & Emergency Light x1 15 Amp AFCI Circuit x2 20 Amp AFCI Circuit x6 15 amp Duplex x7 20 amp GFCI x2 Replace outlet x5 Light Switch x2 3way Light Switch x2 Light Fixture x12 Replace switch x4 FISH ONLY PER 2017 NEC

  7. AppealLIRB Violation Appeal

    Appeal HA-2023-001210 · Closed · Complete

    See Attached

  8. InvestigationL&I investigation

    Case CF-2023-009782 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  9. InvestigationL&I investigation

    Case CF-2023-009782 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  10. CertificationFire Alarm Certification

    Certification BC-2024-001655 · Certified

    Expires 2025-01-09

  11. PermitAddition and/or Alteration

    Permit EP-2023-011187 · Completed

    200amp Panel x1 100 amp 20 circuit sub-panel x4 (In basement, 2nd, 3rd &4th floor hallways) 200 amp Grounding System x1 SMOKE AND CO DETECTOR HARDWIRED INTERCONNECTED x4 20 amp / AFCI Outlet x1 2ND FLOOR - ALL 3 FRONT BEDROOMS AND BATHROOM REWIRE PACKAGE INSTALLATION INCLUDING: - 3 NEW 20 AMP AFCI PROTECTED CIRCUITS - 6 NEW OUTLET LOCATIONS - 1 GFCI OUTLET FOR BATHROOM - REPLACE/INSTALL SWITCHES AND LIGHTING 2 ADDITIONAL BEDROOMS: - 4 NEW 20 AMP AFCI PROTECTED CIRCUITS - 12 NEW OUTLET LOCATIONS - REPLACE/INSTALL SWITCHES AND LIGHTING FISH ONLY PER 2017 NEC

  12. InvestigationL&I investigation

    Case CF-2023-009782 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  13. CertificationFire Escape Report

    Certification BC-2023-022808 · Safe

    Expires 2028-05-23

  14. CertificationFire Escape Report

    Certification BC-2023-012058 · Safe

    Expires 2028-05-23

  15. ViolationRENTAL LICENSE MULTI FAMILY (R2)

    Case CF-2023-009782 · Violation VI-2023-007698 · Code 9-3902 (2) · CLOSED

    Resolution: CLOSED - STOP PROCESSING City marked the record closed; open the case for the closing reason.

  16. InvestigationL&I investigation

    Case 624378 · PASSED

    The cited inspection visit was marked passed.

  17. InvestigationL&I investigation

    Case CF-2023-009782 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  18. InvestigationL&I investigation

    Case CF-2022-082426 · PASSED

    The cited inspection visit was marked passed.

  19. ViolationFIRE ESCAPE REPORT REQUIRED

    Case CF-2022-082426 · Violation VI-2022-060391 · Code F-1104.16.5.1.8 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  20. InvestigationL&I investigation

    Case CF-2022-082426 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  21. CertificationFire Alarm Certification

    Certification BC-2022-001202 · Deficient

  22. License terminal eventPHI ALPHA SIGMA: Rental landlord or residential registration marked inactive

    License 214518 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  23. InvestigationCSUINITIAL

    Case 595082 · PASSED

    The cited inspection visit was marked passed.

  24. CertificationFire Escape Report

    Certification BC-2023-014909 · Safe

    Expires 2023-12-26

  25. CertificationFire Escape Report

    Certification BC-2023-007907 · Safe

    Expires 2023-12-26

  26. PermitMajor alteration

    Permit 928260 · COMPLETED

    MAKE SAFE PERMIT TO COMPLY CASE NO. 595082. ALL WORK TO BE DONE IN ACCORDANCE WITH ENGINEER'S REPORT AND APPROVED PLANS. ANY WORK BEYOND THE SCOPE OF THE ENGINEER'S REPORT REQUIRES SEPARATE PERMIT. IN ACCORDANCE WITH CODE BULLETIN PM-1801, A PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION.

  27. InvestigationCSUINITIAL

    Case 595082 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  28. InvestigationCI INSP

    Case 624378 · CLOSED

    City marked the record closed; open the case for the closing reason.

  29. InvestigationCI INSP

    Case 624378 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  30. InvestigationCI INSP

    Case 629609 · PASSED

    The cited inspection visit was marked passed.

  31. ViolationRENEW LIC INDICATED

    Case 624378 · Violation 211945344 · Code LR-1 · CLOSED

    Resolution: CLOSED - REISSUED/REWRITTEN City marked the record closed; open the case for the closing reason.

  32. InvestigationCI INSP

    Case 624378 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  33. InvestigationCSUINITIAL

    Case 595082 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  34. ViolationEXTERIOR STRUCT UNSAFE COND 11

    Case 595082 · Violation 4710067 · Code PM15-304.1K · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  35. ViolationUNSAFE STRUCTURE

    Case 595082 · Violation 4710066 · Code PM15-108.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  36. InvestigationCSUINITIAL

    Case 595082 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  37. CertificationFire Escape Report

    Certification BC-2023-007818 · Unsafe

  38. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 138679 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  39. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 138679 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  40. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 138679 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  41. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 138679 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  42. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 138679 · CANCELLED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file.

  43. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 138679 · CLOSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.

  44. ViolationFIRE-DOOR STAIR 1HR RATING

    Case 138679 · Violation 1959685 · Code FC-704.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  45. ViolationINT DOOR SELF-CLOSE

    Case 138679 · Violation 1959684 · Code FC-703.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  46. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 138679 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  47. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 138679 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  48. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 138679 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  49. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 104101 · PASSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.

  50. ViolationEGRESS CLEAR OBSTRUCTION

    Case 104101 · Violation 508883 · Code FC-1027.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  51. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 104101 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  52. License issue eventPHI ALPHA SIGMA: Rental landlord or residential registration initially issued

    License 214518 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 11:53 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)