Property report

324-28 S 19th St

13 stories35,208 sqftRSA5built 1920

Property at a glanceApartment building

326 S 19th St Assoc & General Partnership

2026 assessment
$5.7M OPA value, not a listing price
2027 published assessment
$7.3M Future roll, not the current tax bill
Neighborhood area
Rittenhouse · Logan Square Approximate · based on ZIP 19103
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $7,282,700. It is not yet the billed-year tax basis.

$0$5.0M$10M$7.3M2006201020142018202220262027
Property assessmentAssessmentL&I violationPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record144 events · exact dates, newest first
  1. InspectionL&I investigation
  2. CertificationFacade Report
  3. L&I violationFACADES
  4. InspectionL&I investigation
  5. CertificationEmergency and Standby Power Systems Certification
  6. CertificationFire Alarm Certification
  7. CertificationEmergency and Standby Power Systems Certification
  8. CertificationSprinkler Certification
  9. CertificationEmergency and Standby Power Systems Certification
  10. CertificationFire Alarm Certification
  11. CertificationEmergency and Standby Power Systems Certification
  12. CertificationFire Alarm Certification
  13. CertificationSprinkler Certification
  14. CertificationFire Alarm Certification
  15. CertificationEmergency and Standby Power Systems Certification
  16. PermitCertificate of Occupancy (CO) (may inclu…
  17. InspectionL&I investigation
  18. CertificationFire Escape Report
  19. InspectionL&I investigation
  20. InspectionL&I investigation
  21. L&I violationFIRE ESCAPE REPORT REQUIRED
  22. InspectionL&I investigation
  23. CertificationSprinkler Certification
  24. CertificationFire Alarm Certification
  25. PermitAddition and/or Alteration
  26. L&I violationFIRE ESCAPE REPORT REQUIRED
  27. InspectionL&I investigation
  28. CertificationEmergency and Standby Power Systems Certification
  29. PermitAddition and/or Alterations
  30. PermitAddition and/or Alteration
  31. PermitRough-In
  32. CertificationFire Escape Report
  33. PermitAlterations
  34. PermitAddition and/or Alteration
  35. PermitAddition and/or Alterations
  36. PermitAddition and/or Alteration
  37. CertificationFire Alarm Certification
  38. CertificationSprinkler Certification
  39. PermitChange of Use
  40. InspectionL&I investigation
  41. L&I violationFIRE PROTECTION ROOM MARKED
  42. L&I violationEVACUATION PLAN CONTENT
  43. L&I violationADMINISTRATION GENERAL
  44. InspectionL&I investigation
  45. PermitAddition and/or Alteration
  46. PermitAddition and/or Alteration
  47. PermitAlterations
  48. PermitAddition and/or Alterations
  49. PermitAddition and/or Alteration
  50. InspectionL&I investigation
  51. PermitInterior Non-Load-Bearing Wall Demo.
  52. CertificationFacade Report
  53. L&I violationFACADES
  54. InspectionL&I investigation
  55. InspectionPRECOURT (likely: pre-court compliance inspection)
  56. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  57. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  58. PermitDemolition
  59. L&I violationINTERIOR SURFACES
  60. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  61. L&I violationCOULD NOT ENTER
  62. CertificationFire Escape Report
  63. PermitElectrical
  64. PermitMechanical
  65. PermitPlumbing
  66. PermitMajor alteration
  67. PermitMechanical
  68. PermitElectrical
  69. PermitDemolition
  70. PermitPlumbing
  71. PermitMajor alteration
  72. PermitElectrical
  73. PermitMechanical
  74. PermitPlumbing
  75. PermitMajor alteration
  76. PermitDemolition
  77. PermitSuppression
  78. PermitElectrical
  79. InspectionBP_BLDG
  80. PermitMechanical
  81. InspectionBP_BLDG
  82. PermitMajor alteration
  83. PermitPlumbing
  84. PermitMechanical
  85. PermitMechanical
  86. PermitDemolition
  87. PermitElectrical
  88. L&I violationPERMB- FINAL PRE-CO INSP
  89. InspectionBP_BLDG
  90. PermitElectrical
  91. PermitPlumbing
  92. PermitPlumbing
  93. PermitMajor alteration
  94. PermitMajor alteration
  95. CertificationFacade Report
  96. InspectionCI INSP
  97. L&I violationPENALTY- NO ELEC PERM INFO
  98. PermitPlumbing
  99. PermitMajor alteration
  100. PermitMechanical
  101. PermitElectrical
  102. L&I violationFIRE-ELECT OPEN JUNCTION BOX
  103. L&I violationEGRESS LIGHTING REQ
  104. L&I violationVIOL C&I MESSAGE
  105. L&I violationHAZMAT-ELEC WIR/EQIP INST/MAIN
  106. InspectionCI INSP
  107. InspectionBP_BLDG
  108. PermitMechanical
  109. PermitMechanical
  110. PermitElectrical
  111. PermitMechanical
  112. PermitMechanical
  113. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  114. PermitDemolition
  115. InspectionBP_BLDG
  116. PermitPlumbing
  117. PermitPlumbing
  118. PermitPlumbing
  119. PermitPlumbing
  120. PermitMajor alteration
  121. PermitMajor alteration
  122. PermitMajor alteration
  123. PermitMajor alteration
  124. InspectionCI INSP
  125. InspectionCI INSP
  126. L&I violationELEVATORS POST EMERGENCY SIGN
  127. L&I violationFIRE-DOOR/HARDWARE MAINTAIN
  128. L&I violationFIRE-ELECT OPEN JUNCTION BOX
  129. L&I violationSHELTER PLN-REQ¿D
  130. L&I violationEGRESS CLEAR OBSTRUCTION
  131. L&I violationVIOL C&I MESSAGE
  132. InspectionCI INSP
  133. InspectionCI INSP
  134. LicenseRITTENHOUSE REALTY ASSOCIATES: High Rise L&I license filing initially issued
  135. L&I violationVIOL C&I MESSAGE
  136. L&I violationHIRISE-PAY HIRISE FEE
  137. InspectionCI INSP
  138. InspectionCI INSP
  139. L&I violationHIRISE-PAY HIRISE FEE
  140. L&I violationLICENSE-RES MFD
  141. InspectionCI INSP
  142. LicenseRITTENHOUSE INVESTMENT PARTNER: Dumpster License - Private Property L&I license filing initially issued
  143. PermitPlumbing
  144. LicenseRITTENHOUSE REALTY ASSOCIATES: Rental landlord or residential registration initially issued

Verify the public record

$80,210/year estimated property tax

2026 taxable assessment $5,730,100 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $7,282,700. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881022000
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Apartment building, recorded in the City's multi-family category. The public record and owner trail follow.

What it is
Apartment building Apts 5-50 Units Masonry
Owner
326 S 19th St Assoc & General Partnership
$ / sq ft
$207 assessed value ÷ interior sqft
Licensed units
27 active rental license
Interior area
35,208 sqft
Lot size
3,000 sqft
Stories
13
Built
1920
Zoning
RSA5

Recorded owner

Who's behind it

326 S 19th St Assoc & General Partnership · corporate / LLC owner

• Tax bills mail to 301 S 19th St, Philadelphia PA, 19103
• Holds an active rental license for this address

Block context

300 block of S 19th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 318-22 S 19th St  ·  330 S 19th St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 21, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

RITTENHOUSE REALTY ASSOCIATESActive

Rental · Initial issue date Sep 14, 2006 · Filed expiration Feb 28, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 144 dated rows
  1. InvestigationL&I investigation

    Case CF-2026-032967 · PASSED

    The cited inspection visit was marked passed.

  2. CertificationFacade Report

    Certification BC-2026-012178 · Safe with Repair

    Expires 2031-04-28

  3. ViolationFACADES

    Case CF-2026-032967 · Violation VI-2026-020021 · Code PM15-315.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  4. InvestigationL&I investigation

    Case CF-2026-032967 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  5. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2026-017075 · Certified

    Expires 2027-02-20

  6. CertificationFire Alarm Certification

    Certification BC-2026-017074 · Certified

    Expires 2027-02-20

  7. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2026-003031 · Certified

    Expires 2027-01-20

  8. CertificationSprinkler Certification

    Certification BC-2025-006851 · Certified

    Expires 2026-03-04

  9. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-007890 · Certified

    Expires 2026-02-26

  10. CertificationFire Alarm Certification

    Certification BC-2025-007889 · Certified

    Expires 2026-02-26

  11. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-004226 · Certified

    Expires 2026-01-22

  12. CertificationFire Alarm Certification

    Certification BC-2024-015475 · Deficient

  13. CertificationSprinkler Certification

    Certification BC-2024-012955 · Certified

    Expires 2025-03-05

  14. CertificationFire Alarm Certification

    Certification BC-2024-005490 · Certified

    Expires 2025-02-22

  15. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017759 · Certified

    Expires 2025-01-23

  16. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2023-003987 · Expired

    CO only for existing 26 dwelling units. See CP-2022-001162 for the completed level II alteration with partial change of occupancy classification without change to the existing total number of dwelling units.

  17. InvestigationL&I investigation

    Case CF-2023-005086 · PASSED

    The cited inspection visit was marked passed.

  18. CertificationFire Escape Report

    Certification BC-2023-011272 · Safe

    Expires 2028-05-25

  19. InvestigationL&I investigation

    Case CF-2023-005086 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  20. InvestigationL&I investigation

    Case CF-2022-056739 · PASSED

    The cited inspection visit was marked passed.

  21. ViolationFIRE ESCAPE REPORT REQUIRED

    Case CF-2022-056739 · Violation VI-2023-024935 · Code F-1104.16.5.1.10.1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. InvestigationL&I investigation

    Case CF-2022-056739 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  23. CertificationSprinkler Certification

    Certification BC-2021-000032 · Certified

    Expires 2024-03-02

  24. CertificationFire Alarm Certification

    Certification BC-2023-004224 · Certified

    Expires 2024-02-23

  25. PermitAddition and/or Alteration

    Permit CP-2022-007103 · Expired

    LEVEL I ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR REPAIRS TO EXISTING FIRE ESCAPE BALCONIES AS PER APPROVED PLANS. *2018 IEBC REVIEW*

  26. ViolationFIRE ESCAPE REPORT REQUIRED

    Case CF-2023-005086 · Violation VI-2023-004020 · Code F-1104.16.5.1.10.R · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  27. InvestigationL&I investigation

    Case CF-2023-005086 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  28. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017657 · Certified

    Expires 2024-01-13

  29. PermitAddition and/or Alterations

    Permit FP-2022-001945 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (35) sprinkler heads

  30. PermitAddition and/or Alteration

    Permit EP-2022-007145 · Completed

    Part of the first floor is being renovated. The only work being done is in the first floor apartment and in the first floor fitness center. In the apartment, we are adding the required low frequency horn notification in the bedrooms and in the living room, with the provisions for strobes to be added in the future. In the fitness center, will will add a horn/strobe for notification. In the fitness center, we will add a smoke detector to the existing first floor zone. A NAC panel will be installed in the basement next to the existing fire alarm control panel. The existing fire alarm control panel will activate the new NAC panel. One circuit from the NAC panel will power the new notification devices on the first floor. The existing notification on the first floor will remain as-is and will not be modified or changed as per 2016 NFPA 72.

  31. PermitRough-In

    Permit EP-2022-007149 · Completed

    Rough-In Permit for EP-2022-007145 Part of the first floor is being renovated. The only work being done is in the first floor apartment and in the first floor fitness center. In the apartment, we are adding the required low frequency horn notification in the bedrooms and in the living room, with the provisions for strobes to be added in the future. In the fitness center, will will add a horn/strobe for notification. In the fitness center, we will add a smoke detector to the existing first floor zone. A NAC panel will be installed in the basement next to the existing fire alarm control panel. The existing fire alarm control panel will activate the new NAC panel. One circuit from the NAC panel will power the new notification devices on the first floor. The existing notification on the first floor will remain as-is and will not be modified or changed as per nfpa 72

  32. CertificationFire Escape Report

    Certification BC-2022-007570 · Safe with Repair

    Expires 2022-11-20

  33. PermitAlterations

    Permit PP-2022-006602 · Completed

    Plumbing Permit (Interior) for combo CP-2022-001162

  34. PermitAddition and/or Alteration

    Permit EP-2022-004237 · Completed

    Electrical Permit for combo CP-2022-001162

  35. PermitAddition and/or Alterations

    Permit MP-2022-002411 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2022-001162

  36. PermitAddition and/or Alteration

    Permit CP-2022-001162 · Completed

    For level II alteration with partial change of occupancy classification as per approved plans. No change to the existing total number of dwelling units. Asbestos to be removed prior to start of other work. Separate permits required for MEPS work. Amendment to confirm the building currently has the basement and part of the 1st floor sprinklered with standpipes in the stair towers. Additional sprinklers for the 1st floor spaces, augmenting the existing basement sprinklers. Existing standpipes are to remain.

  37. CertificationFire Alarm Certification

    Certification BC-2022-002704 · Certified

    Expires 2023-02-24

  38. CertificationSprinkler Certification

    Certification BC-2022-004456 · Certified

    Expires 2023-02-08

  39. PermitChange of Use

    Permit ZP-2021-015408 · Issued

    Residential - Household Living - Multi-Family

  40. InvestigationL&I investigation

    Case CF-2021-105268 · PASSED

    The cited inspection visit was marked passed.

  41. ViolationFIRE PROTECTION ROOM MARKED

    Case CF-2021-105268 · Violation VI-2021-075801 · Code FC-13-509.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  42. ViolationEVACUATION PLAN CONTENT

    Case CF-2021-105268 · Violation VI-2021-075799 · Code FC-13-404.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  43. ViolationADMINISTRATION GENERAL

    Case CF-2021-105268 · Violation VI-2021-075798 · Code FC-13-101 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  44. InvestigationL&I investigation

    Case CF-2021-105268 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  45. PermitAddition and/or Alteration

    Permit CP-2021-006448 · Expired

    For exterior alterations to repair fa?ade including lintel rehabilitation, parapet rebuild and brick rebuild as per plans.

  46. PermitAddition and/or Alteration

    Permit EP-2021-006221 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING DWELLING UNIT 1A WITHIN AN EXISTING MULTI-FAMILY DWELLING AS PER APPROVED PLANS. ALL WORK WITHIN DWELLING UNIT. EXISTING BUILDING, NO CHANGE OF OCCUPANCY, NOT REQUIRED TO BE SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  47. PermitAlterations

    Permit PP-2021-010500 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING DWELLING UNIT 1A WITHIN AN EXISTING MULTI-FAMILY DWELLING AS PER APPROVED PLANS. ALL WORK WITHIN DWELLING UNIT. EXISTING BUILDING, NO CHANGE OF OCCUPANCY, NOT REQUIRED TO BE SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  48. PermitAddition and/or Alterations

    Permit MP-2021-003756 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING DWELLING UNIT 1A WITHIN AN EXISTING MULTI-FAMILY DWELLING AS PER APPROVED PLANS. ALL WORK WITHIN DWELLING UNIT. EXISTING BUILDING, NO CHANGE OF OCCUPANCY, NOT REQUIRED TO BE SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  49. PermitAddition and/or Alteration

    Permit CP-2021-003390 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING DWELLING UNIT 1A WITHIN AN EXISTING MULTI-FAMILY DWELLING AS PER APPROVED PLANS. ALL WORK WITHIN DWELLING UNIT. EXISTING BUILDING, NO CHANGE OF OCCUPANCY, NOT REQUIRED TO BE SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  50. InvestigationL&I investigation

    Case CF-2021-008678 · PASSED

    The cited inspection visit was marked passed.

  51. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2021-001965 · Completed

    EZ INTERIOR DEMOLITION- **Existing Philadelphia Historic Property**For the interior demolition on non-bearing partition wall and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work. (No Demo Work to Fire-Rated Assemblies or plans will be required) Separate permit required for Building and MEP. **No work to exterior windows and/or doors as part of this permit. No exterior work permitted as part of this permit. For the interior demolition of non-bearing partition walls and ceiling in accordance with the attached EZ Permit Interior Demolition Standard. Failure to comply with the attached EZ Permit Interior Demolition Standard shall result in revocation of this permit. as per PHC**

  52. CertificationFacade Report

    Certification BC-2021-000660 · Safe with Repair

    Expires 2026-03-09

  53. ViolationFACADES

    Case CF-2021-008678 · Violation VI-2021-006466 · Code PM15-315.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  54. InvestigationL&I investigation

    Case CF-2021-008678 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  55. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 658034 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  56. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 658034 · CLOSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.

  57. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 658034 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  58. PermitDemolition

    Permit 911329 · COMPLETED

    EZ INTERIOR DEMOLITION-INTERIOR DEMO OF NONLOAD BEARING WALLS IN THE BASEMENT - FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. NO OTHER WORK ON THIS PERMIT.

  59. ViolationINTERIOR SURFACES

    Case 658034 · Violation 5135521 · Code PM15-305.3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  60. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 658034 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  61. ViolationCOULD NOT ENTER

    Case 716277 · Violation 4488521 · Code A.CNE.000 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  62. CertificationFire Escape Report

    Certification BC-2022-016269 · Safe

    Expires 2022-06-01

  63. PermitElectrical

    Permit 722814 · COMPLETED

    INSTALL WIRING FOR NEW FLOOR PLAN. INSTALL NEW FIXTURES, DEVICES AND 100AMP PANEL.(CC DISTRICT)

  64. PermitMechanical

    Permit 725529 · EXPIRED

    INSTALL (1) HEAT PUMP WITH DUCTWORK. (MULTI-FAMILY) APPROVED BY THE PHC. UNIT NOT TO BE VISIBLE FROM RIGHT OF WAY

  65. PermitPlumbing

    Permit 720594 · COMPLETED

    WATER & DRAIN LINE FOR 2-TOILET, 2-SINK, 1-TUB, 1-SHOWER, 1-KITCHEN SINK, 1-DISPOSA L& 1-DISWASHER THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  66. PermitMajor alteration

    Permit 716277 · EXPIRED

    INTERIOR RENOVATION OF ENTIRE APARTMENT INCLUDING: NEW PARTITIONS, DRYWALL, NEW KITCHEN AND BATH, AND NEW FLOORING THROUGHOUT.

  67. PermitMechanical

    Permit 712932 · COMPLETED

    INSTALL OF A 2 TON HEAT PUMP SYSTEM WITH DUCTWORK. CONDENSER INSTALLED SEPARATE FROM FIVE LANDING INSIDE CLOSEST PER PHC. UNITS NO TO BE SEEN FROM A PUBLIC RIGHT OF WAY.EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  68. PermitElectrical

    Permit 703126 · COMPLETED

    REPLACING WIRING THROUGHOUT UNIT AND REPLACE 100A PANEL PER 2008 NEC (MULTI FAMILY)CC DISTRICT

  69. PermitDemolition

    Permit 708349 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  70. PermitPlumbing

    Permit 699869 · COMPLETED

    REMODEL APARTMENT, KITCHEN SINK, DISPOSAL, DISHWASHER, BATHROOM WATER CLOSET, LAVY SINK, TUB, NEW MASTER BATHRROM, WATER CLOSET, LAVY SINK SHOWER DRAINS & WATER LINES- THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  71. PermitMajor alteration

    Permit 695323 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING DWELLING UNIT AS SHOWN PER APPROVED PLANS. ALTERATIONS TO THE INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS, PROVIDE FINISHES AND APPLIANCES THROUGHOUT. NO CHANGES TO EXTERIOR, NO WORK ON WINDOWS OR DOORS AS PER HISTORICAL COMMISSION APPROVAL. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK.

  72. PermitElectrical

    Permit 680225 · COMPLETED

    REWIRE UNIT FOR RENOVATION INSTALL RECEPTACLES AND DEVICES, FIXTURES RELOCATE 100A PANEL AS PER NEC 2008 CC DISTRICT

  73. PermitMechanical

    Permit 681029 · COMPLETED

    INSTALL (1) HEAT PUMP SYSTEM WITH DUCTWORK. (MULTI-FAMILY) CONDENSER INSTALLED SEPARATE FROM FIRE LANDING INSIDE CLOSEST PER PHC.

  74. PermitPlumbing

    Permit 681031 · COMPLETED

    NEW MASTER AND HALLWAY BATHROOMS NEW WATER AND DRAINS LINES,STAND PIPE FOR LAUNDRY,NEW KITCHEN DRAIN AND WATER LINES,NEW SINK FAUCET,GARBAGE DISPOSAL AND DISHWASHER (MULTI FAMILY)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  75. PermitMajor alteration

    Permit 674957 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO EXISTING DWELLING UNIT 11B WITHIN AN EXISTING MULTI-FAMILY DWELLING AS PER APPROVED PLANS. ALL WORK WITHIN DWELLING UNIT. EXISTING BUILDING, NO CHANGE OF OCCUPANCY, NOT REQUIRED TO BE SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  76. PermitDemolition

    Permit 674952 · COMPLETED

    INTERIOR DEMOLITION OF NON LOAD BEARING COMPONENTS IN ACCORDANCE WITH EZ PERMIT STANDARD. DEVIATION FROM STANDARD SHALL RESULT IN PERMIT REVOCATION.

  77. PermitSuppression

    Permit 663593 · EXPIRED

    FOR THE INSTALLATION OF A NEW BACKFLOW PREVENTION ASSEMBLY AND JOCKEY PUMP SERVING A NEXISTING FIRE SUPPRESSION SYSTEM.

  78. PermitElectrical

    Permit 629964 · COMPLETED

    REWIRE APT TO FIT NEW LAYOUT. INSTALL PANEL. INSTALL NEW DEVICES AND FIXTURES. INSTALL NEW WIRING. AS PER NEC 2008 CC DISTRICT

  79. InvestigationBP_BLDG

    Case 489556 · PASSED

    The cited inspection visit was marked passed.

  80. PermitMechanical

    Permit 633504 · COMPLETED

    INSTALLATION OF A NEW 2 TON HEAT PUMP SYSTEM. OUTDOOR UNITS TO BE LOCATED IN REAR, ENCLOSED IN EXISTING ENCLOSURE. NOT VISIBLE FROM PUBLIC RIGHT OF WAY. NO WORK TO FRONT FACADE.

  81. InvestigationBP_BLDG

    Case 489556 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  82. PermitMajor alteration

    Permit 624160 · COMPLETED

    FOR INTERIOR ALTERATIONS TO INCLUDE THE INSTALLATION OF NEW INTERIOR PARTITION WALLS, AND WALL/CEILING/FLOOR FINISHING. (IEBC 2009, COMPLIANCE PATH: WORK-AREA METHOD, LVL II) NO EXTERIOR WORK ON THIS PERMIT.

  83. PermitPlumbing

    Permit 629246 · COMPLETED

    NEW KITCHEN DRAINS AND WATER LINES,NEW SINK,DIPOSAL,DISHWASHER,STAND PIPE,DRAIN AND WATER LINES AND FIXTURES FOR MASTER AND HALL BATH (APT BLDG)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  84. PermitMechanical

    Permit 624481 · COMPLETED

    INSTALLATION OF A NEW 2 TON HEAT PUMP SYSTEM. CONDENSOR INSTALLED SEPARATE FROM FIRE LANDING INSIDE CLOSET.

  85. PermitMechanical

    Permit 624482 · COMPLETED

    INSTALLATION OF A NEW 2 TON HEAT PUMP SYSTEM. CONDENSOR INSTALLED SEPARATE FROM FIRE LANDING INSIDE CLOSET.

  86. PermitDemolition

    Permit 624163 · COMPLETED

    DEMO OF ALL NON LOAD BEARING WALLS. KITCHEN CABINETS AND TILE FLOOR. COMPLETE RESTRUCTING OF BATHROOM. NO EXTERIOR WORK EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  87. PermitElectrical

    Permit 624313 · COMPLETED

    INSTALL NEW WIRING THROUGHOUT NEW DEVICES AND FIXTURES. INSTALL NEW PANEL AS PER 2008 NEC (MULTI FAMILY)

  88. ViolationPERMB- FINAL PRE-CO INSP

    Case 489556 · Violation 3671749 · Code A-402.5/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  89. InvestigationBP_BLDG

    Case 489556 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  90. PermitElectrical

    Permit 618303 · COMPLETED

    INSTALL NEW PANEL REWIRE APT AND INSTALL NEW DEVICES, REC, FIXTURE AS PER NEC2008

  91. PermitPlumbing

    Permit 617617 · COMPLETED

    NEW MASTER BATHROOM TWO SINKS, HALL BATHROOM, TOILET,SINK TUB. KITCHEN- SINK,DISPOSAL,DISHWASHER AND LAUNDRY- STANDPIPE.(APT UNIT)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  92. PermitPlumbing

    Permit 617624 · COMPLETED

    MASTER BATHROOM TWO SINKS TOILET ANKD SHOWER. HALL BATHROOM, TOILET SINK AND TUB, KITCHEN SINK DISPOSAL AND DISHWASHER. LAUNDRY STANDPIPE.(APT BLDG)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  93. PermitMajor alteration

    Permit 614240 · COMPLETED

    SELECTIVE INTERIOR DEMOLITION AND LEVEL II ALTERATIONS TO PROVIDE A NEW CONDOMINIUM INTERIOR LAYOUT. WORK INCLUDES NEW WALL INFILL, INTERIOR NON-BEARING PARTITIONS AND INSTALLATION OF LINTELS. **ALL ASBESTOS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK.** SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING SYTEMS. WORK TO BE COMPLETED IN ACCORDANCE WITH PLANS APPROVED BY P.H.C. (06/02/15).

  94. PermitMajor alteration

    Permit 614249 · COMPLETED

    SELECTIVE INTERIOR DEMOLITION AND LEVEL II ALTERATIONS TO PROVIDE A NEW CONDOMINIUM INTERIOR LAYOUT. WORK INCLUDES NEW WALL INFILL, INTERIOR NON-BEARING PARTITIONS AND INSTALLATION OF LINTELS. **ALL ASBESTOS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK.** SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING SYTEMS. WORK TO BE COMPLETED IN ACCORDANCE WITH PLANS APPROVED BY P.H.C. (06/02/15).

  95. CertificationFacade Report

    Certification BC-2022-006604 · Safe with Repair

    Expires 2020-05-05

  96. InvestigationCI INSP

    Case 441887 · PASSED

    The cited inspection visit was marked passed.

  97. ViolationPENALTY- NO ELEC PERM INFO

    Case 438533 · Violation 3227478 · Code A-901.13/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  98. PermitPlumbing

    Permit 551725 · COMPLETED

    REMOVE AND REPLACE PLUMBING FIXTURES (APT BLDG)

  99. PermitMajor alteration

    Permit 548398 · COMPLETED

    SELECTIVE INTERIOR DEMOLITION AND LEVEL II ALTERATIONS TO PROVIDE A NEW CONDOMINIUM INTERIOR LAYOUT. WORK INCLUDES NEW WALL INFILL, INTERIOR NON-BEARING PARTITIONS AND INSTALLATION OF LINTELS. **ALL ASBESTOS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK.** SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING SYTEMS. WORK TO BE COMPLETED IN ACCORDANCE WITH PLANS APPROVED BY P.H.C. (07/07/14).

  100. PermitMechanical

    Permit 551129 · COMPLETED

    REPLACE SPLIT SYSTEM IN EXISTING SPACE AND REPLACING 2 GRD'S. * NO WORK/CHANGES TO EXTERIOR OR WINDOWS/DOORS AS PER HISTORICAL COMMISSION GUIDELINES.

  101. PermitElectrical

    Permit 547340 · COMPLETED

    RENOVATION TO UNIST 1B,2B,12A, AND PH PER 2008 NEC & NFPA 72 (APT BLDG)

  102. ViolationFIRE-ELECT OPEN JUNCTION BOX

    Case 441887 · Violation 3249115 · Code FC-605.6/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  103. ViolationEGRESS LIGHTING REQ

    Case 441887 · Violation 3249113 · Code FC-1006.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  104. ViolationVIOL C&I MESSAGE

    Case 441887 · Violation 3249112 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  105. ViolationHAZMAT-ELEC WIR/EQIP INST/MAIN

    Case 441887 · Violation 3249114 · Code FC-2703.9/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  106. InvestigationCI INSP

    Case 441887 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  107. InvestigationBP_BLDG

    Case 438533 · PASSED

    The cited inspection visit was marked passed.

  108. PermitMechanical

    Permit 545153 · COMPLETED

    REPLACE EXISTING SPLIT SYSTEM, AND ALL RELATED DUCTWORK AND REGISTERS.

  109. PermitMechanical

    Permit 545160 · COMPLETED

    REPLACE EXISTING SPLIT SYSTEM, AND ALL RELATED DUCTWORK AND REGISTERS.

  110. PermitElectrical

    Permit 547344 · COMPLETED

    RENOVATION TO UNITS 7A AND 7B PER 2008 NEC & NFPA 72 (APT BLDG)

  111. PermitMechanical

    Permit 545158 · COMPLETED

    DUCTWORK AND GRD'S OFF REPLACEMENT SPLIT SYSTEM DUCTWORK AND REGISTERS-OFFICE

  112. PermitMechanical

    Permit 545159 · COMPLETED

    REPLACE EXISTING SPLIT SYSTEM, AND ALL RELATED DUCTWORK AND REGISTERS.

  113. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 438533 · Violation 3226651 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  114. PermitDemolition

    Permit 544464 · COMPLETED

    INT DEMO OF EXISTING NON LOAD BEARING PARTITIONS AND FINISHES

  115. InvestigationBP_BLDG

    Case 438533 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  116. PermitPlumbing

    Permit 543042 · COMPLETED

    UNIT 1B - INTERIOR PLUMBING ALTERATIONS - REMOVE THE EXISTING PLUMBING FIXTURES - MODIFY ROUGH-IN AS NECESSARY TO ACCOMODATE THE NEW FIXTURE LAYOUT - NOTE: NO INCREASE AND/OR ADDITIONAL LOAD TO THE PLUMBING SYSTEM

  117. PermitPlumbing

    Permit 543048 · COMPLETED

    UNIT 2B - INTERIOR PLUMBING ALTERATIONS - REMOVE EXISTING PLUMBING FIXTURES - MODIFY THE ROUGH-IN AS NECESSARY TO ACCOMODATE THE NEW FIXTURE LAYOUT - NOTE: NO INCREASE IN THE FIXTURE COUNT OR ADDITIONAL LOAD ON THE PLUMBING SYSTEM

  118. PermitPlumbing

    Permit 543047 · COMPLETED

    PENTHOUSE - INTERIOR PLUMBING ALTERATIONS - REMOVE EXISTING PLUMBING FIXTURES - MODIFY THE ROUGH-IN AS NECESSARY TO ACCOMODATE THE NEW FIXTURE LAYOUT - NOTE: NO INCREASE IN THE FIXTURE COUNT OR ADDITIONAL LOAD ON THE PLUMBING SYSTEM

  119. PermitPlumbing

    Permit 543049 · COMPLETED

    7TH FLOOR - UNITS 7A & 7B - INTERIOR PLUMBING ALTERATIONS - REMOVE EXISTING PLUMBING FIXTURES - MODIFY THE ROUGH-IN AS NECESSARY TO ACCOMODATE THE NEW FIXTURE LAYOUT - NOTE: NO INCREASE IN THE FIXTURE COUNT OR ADDITIONAL LOAD ON THE PLUMBING SYSTEM

  120. PermitMajor alteration

    Permit 534821 · COMPLETED

    FOR LEVEL II ALTERATIONS TO PENTHOUSE AS SHOWN PER APPROVED PLANS. ALTERATIONS TO THE INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS, PROVIDE FINISHINGS AND APPLIANCES THROUGHOUT. NO CHANGES TO EXTERIOR, NO WORK ON WINDOWS OR DOORS AS PER HISTORICAL COMMISSION APPROVAL. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK.

  121. PermitMajor alteration

    Permit 535235 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING DWELLING UNIT AS SHOWN PER APPROVED PLANS. ALTERATIONS TO THE INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS, PROVIDE FINISHINGS AND APPLIANCES THROUGHOUT. NO CHANGES TO EXTERIOR, NO WORK ON WINDOWS OR DOORS AS PER HISTORICAL COMMISSION APPROVAL. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK.

  122. PermitMajor alteration

    Permit 534828 · COMPLETED

    FOR LEVEL II ALTERATIONS TO AN EXISTING DWELLING UNIT AS SHOWN PER APPROVED PLANS. ALTERATIONS TO THE INCLUDE THE DEMOLITION/ERECTION OF NON BEARING PARTITION WALLS, PROVIDE FINISHINGS AND APPLIANCES THROUGHOUT. NO CHANGES TO EXTERIOR, NO WORK ON WINDOWS OR DOORS AS PER HISTORICAL COMMISSION APPROVAL. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK.

  123. PermitMajor alteration

    Permit 533696 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS TO TWO (2) DWELLING UNITS ON THE SEVENTH FLOOR AS PER APPROVED PLANS. NO CHANGES TO EXTERIOR OR WORK ON WINDOWS OR DOORS AS PER PHILADELPHIA HISTORICAL COMMISSION APPROVAL.

  124. InvestigationCI INSP

    Case 414603 · PASSED

    The cited inspection visit was marked passed.

  125. InvestigationCI INSP

    Case 414603 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  126. ViolationELEVATORS POST EMERGENCY SIGN

    Case 414603 · Violation 3070970 · Code FC-607.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  127. ViolationFIRE-DOOR/HARDWARE MAINTAIN

    Case 414603 · Violation 3070971 · Code FC-703.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  128. ViolationFIRE-ELECT OPEN JUNCTION BOX

    Case 414603 · Violation 3070968 · Code FC-605.6/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  129. ViolationSHELTER PLN-REQ¿D

    Case 414603 · Violation 3070967 · Code FC-409.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  130. ViolationEGRESS CLEAR OBSTRUCTION

    Case 414603 · Violation 3070966 · Code FC-1027.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  131. ViolationVIOL C&I MESSAGE

    Case 414603 · Violation 3070965 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  132. InvestigationCI INSP

    Case 414603 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  133. InvestigationCI INSP

    Case 394086 · PASSED

    The cited inspection visit was marked passed.

  134. License issue eventRITTENHOUSE REALTY ASSOCIATES: High Rise L&I license filing initially issued

    License 602626 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  135. ViolationVIOL C&I MESSAGE

    Case 394086 · Violation 2878917 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  136. ViolationHIRISE-PAY HIRISE FEE

    Case 394086 · Violation 2878918 · Code FC-408.12/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  137. InvestigationCI INSP

    Case 270913 · PASSED

    The cited inspection visit was marked passed.

  138. InvestigationCI INSP

    Case 394086 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  139. ViolationHIRISE-PAY HIRISE FEE

    Case 270913 · Violation 2023608 · Code FC-408.12/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  140. ViolationLICENSE-RES MFD

    Case 270913 · Violation 2023609 · Code PM-102.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  141. InvestigationCI INSP

    Case 270913 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  142. License issue eventRITTENHOUSE INVESTMENT PARTNER: Dumpster License - Private Property L&I license filing initially issued

    License 517314 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  143. PermitPlumbing

    Permit 193197 · COMPLETED

    METER REDUCTION FROM 3" TO 2"

  144. License issue eventRITTENHOUSE REALTY ASSOCIATES: Rental landlord or residential registration initially issued

    License 353420 · Active

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 22, 2026, 7:34 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)