Multi-family report

3825 Lancaster Ave

3 stories3,300 sqftRM1built 2025

Property at a glanceMulti-family

Individual, other or unknown mailing address

2026 assessment
$152K OPA value, not a listing price
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

Published City assessments for this building against its block and ZIP. Dated City filings are marked on the same line. Select one to read it. Assessments are tax-roll values, not sale prices or appraisals.

$0$500K$1.0MZIP 19104 (University City · West Powelton) median$775K2015201720192021202320252027
Property assessmentBlock median & rangeZIP 19104 (University City · West Powelton) medianAssessmentL&I violationPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record25 events · exact dates, newest first
  1. LicenseJENNIFER TSANG & YE JIN TANG: Rental landlord or residential registration initially issued
  2. PermitAlterations
  3. PermitNew Construction
  4. PermitNew Construction
  5. PermitNew Construction
  6. PermitNew Construction or Additions
  7. PermitNew Construction or Additions
  8. PermitNew Construction
  9. PermitNew construction, addition, GFA change
  10. PermitZoning/use
  11. InspectionPRECOURT (likely: pre-court compliance inspection)
  12. PermitPlumbing
  13. InspectionBP_BLDG
  14. InspectionBP_BLDG
  15. InspectionBP_BLDG
  16. InspectionBP_BLDG
  17. L&I violationPERMB- TOTAL DEMOL
  18. L&I violationSTOP WORK ORDER
  19. L&I violationSTOP WORK ORDER
  20. InspectionBP_BLDG
  21. InspectionBP_BLDG
  22. PermitZoning/use
  23. L&I violationWORKMANLIKE- BUILDING CODE
  24. PermitAddition
  25. PermitZoning/use

Flags: active rental license. Informational only. Not investment advice or a consumer report (FCRA).

Verify the public record

$2,125/year estimated property tax

2026 taxable assessment $151,800 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $775,000. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 241144400
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

The property, on paper

OPA physical field record.

Stories
3
Interior
3,300 sqft livable area
Lot
1,428 sqft
Heat
Forced hot air city code A
Central air
Yes
Exterior condition
Newer construction city code 1
Newer construction
Interior condition
Newer construction city code 1
Newer construction
Zoning
RM1 city zoning code

OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.

Block context

3800 block of Lancaster Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 3823 Lancaster Ave  ·  3827 Lancaster Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 23, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

JENNIFER TSANG & YE JIN TANGActive

Rental · Initial issue date Dec 22, 2025 · Filed expiration Dec 21, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 25 dated rows
  1. License issue eventJENNIFER TSANG & YE JIN TANG: Rental landlord or residential registration initially issued

    License 0996096 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  2. PermitAlterations

    Permit PP-2025-000600 · Completed

    Installation of a new back-flow assembly

  3. PermitNew Construction

    Permit MP-2024-000051 · Completed

    FOR THE INSTALLATION OF HVAC APPLIANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS. *2018 IMC REVIEW*

  4. PermitNew Construction

    Permit EP-2024-002979 · Completed

    INSTALL A 400 AMP SERVICE, (5) GANG METER BANK, (4) 100 AMP PANELS & FEEDERS, (1) 60 AMP PANEL & FEEDER. INSTALL WIRING THROUGHOUT THE COMMON AREAS AND FOUR DWELLING UNITS. INSTALL LIGHTS NORMAL & EMERGENCY, SWITCHES, SENSORS, RECEPTACLES, SMOKE & CARBON MONOXIDE ALARMS. PROVIDE POWER FOR THE MECHANICAL & HVAC EQUIPMENT. INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.

  5. PermitNew Construction

    Permit FP-2022-003000 · Completed

    FOR THE INSTALLATION OF A 2-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A 2 INCH WILKINS 950XLT2 BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13R. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.

  6. PermitNew Construction or Additions

    Permit PP-2023-015504 · Completed

    Installing 1 1/2" Water Service, 5" Curb Trap, 4" Main Drain, 4" Fresh Air Inlet

  7. PermitNew Construction or Additions

    Permit PP-2023-004692 · Completed

    INSTALL 11 WATER CLOSETS, 11 LAVATORIES, 11SHOWER/TUBS, 11 WASHING MACHINE BOXES, 4 CUP SINKS, 4 KITCHEN SINKS, 4 DISH WASHERS, 4 FLOOR DRAINS, 1 EJECTOR SUMP PUMP, 4 HOT WATER HEATERS, 1 BACKFLOW PREVENTER AND 1 RAIN WATER CONDUCTOR ACCORDING TO THE 2018 PPC AND PER PLANS.

  8. PermitNew Construction

    Permit CP-2021-003904 · Completed

    FOR THE ERECTION OF A THREE (3) STORY ATTACHED STRUCTURE WITH ROOF ACCESS STRUCTURE TO THE ROOF FOR MAINTENANCE ONLY. ROOF IS NOT TO BE USED AS A COMMON ROOF DECK FOR DWELLING UNITS. BUILDING TO CONTAIN FOUR DWELLING UNITS. TYPE B DWELLING UNIT AT 1ST FLOOR. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  9. PermitNew construction, addition, GFA change

    Permit ZP-2021-002439 · Completed

    FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH A CELLAR AND A ROOF DECK WITH A ROOF ACCESS STRUCTURE. THE PROPOSED STRUCTURE MUST COMPLY WITH THE REGULATIONS FOR FENESTRATION AS PER SECTION 14-504(9)(c) OF THE PHILADELPHIA ZONING CODE. SIZE AND LOCATION AS SHOWN ON PLANS.

  10. PermitZoning/use

    Permit 888999 · COMPLETED

    FOR THE ERECTION OF AN ATTACHED BUILDING WITH A ROOF DECK AND PILOT HOUSE (FOR ACCESS TO ROOF DECK ONLY) AND REAR DECKS AT THE SECOND AND THIRD FLOOR LEVELS. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING [FOUR (4) DWELLING UNITS].

  11. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 516212 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  12. PermitPlumbing

    Permit 695499 · COMPLETED

    SEALING LATERAL AND REMOVING CURB TRAP PA20161470780 (SFD)SELF CERTIFICATION'S ARE NO LONGER PERMITTED","ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  13. InvestigationBP_BLDG

    Case 516203 · CLOSED

    City marked the record closed; open the case for the closing reason.

  14. InvestigationBP_BLDG

    Case 516212 · CLOSED

    City marked the record closed; open the case for the closing reason.

  15. InvestigationBP_BLDG

    Case 516203 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. InvestigationBP_BLDG

    Case 516212 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  17. ViolationPERMB- TOTAL DEMOL

    Case 516203 · Violation 3885124 · Code A-301.1/5 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  18. ViolationSTOP WORK ORDER

    Case 516203 · Violation 3885125 · Code A-504.1/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  19. ViolationSTOP WORK ORDER

    Case 516212 · Violation 3885128 · Code A-504.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  20. InvestigationBP_BLDG

    Case 516203 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  21. InvestigationBP_BLDG

    Case 516212 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  22. PermitZoning/use

    Permit 630017 · COMPLETED

    FOR THE COMPLETE DEMO OF EXISTING 3 STORY BUILDING AND FOR THE COMPLETE CONSTRUCTION OF A NEW 3 STORY BUILDING IN THE NEW PROPOSED LOCATION PER SITE AND PLANS.

  23. ViolationWORKMANLIKE- BUILDING CODE

    Case 596937 · Violation 3610414 · Code A-104.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  24. PermitAddition

    Permit 596937 · EXPIRED

    FOR A COMPLETE CHANGE OF OCCUPANCY CLASSIFICATION TO CREATE THREE (3) FAMILY DWELLING, FOR THE ERECTION OF A THREE (3) STORY ABOVE GRADE PLANE ADDITION OF LIGHT-FRAME WOOD CONST. W. CAST-IN-PLACE CONCRETE FOOTINGS & CMU STEM WALLS, & FOR LEVEL III ALTERATIONS THROUGHOUT EXIST. THREE (3) STORY ABOVE GRADE PLANE, W. UNOCCUPIED BASEMENT, BUILDING TO INCLUDE ERECTION OF PARTITION WALLS FOR DWELLING UNIT & EXIT ENCLOSURE SPACES; BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMIT REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, & FIRE SUPPRESSION WORK.

  25. PermitZoning/use

    Permit 580912 · COMPLETED

    FOR THE ERECTION OF USE FROM A SFD TO NEW 3 APTS. FOR THE NEW CONSTRUCTION OF A NEW 3 STORY REAR ADDITION AND 1 STORY REAR ADDITION ON EXISTING 2 STORY REAR FOR A TOTAL OF 3 FLOORS. SIZE AND AREA AS SHOWN PER SITE PLANS SUBMITTED WITH APPLICATIONJ.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 4:59 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)