Apartment building report
400 Market St
12 stories201,828 sqftCMX4built 1971
Lak Market Master Htc Landlord LLC
1 violation row marked OPEN in 1 active case
The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.
High-Rise Building
- High-Rise Building
F-105.6.3
OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.
Assessment and City record timeline
The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.
Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $58,880,800. It is not yet the billed-year tax basis.
- OPA assessment · 2026$10M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2027$59M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- Permit · 2014-09-03New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-05Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-06Rough-InThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-04-15AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-04-20Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-04-21New ConstructionThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-05-28Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-06-04Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-09-09Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-09-17Interior Non-Load-Bearing Wall Demo.This permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-02-23Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-02-23Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-03-28AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-03-28AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-04-07Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-04-11Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-04-11Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-04-20Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-05-25Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-05-25Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-08-29Change of UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-09-24Interior Non-Load-Bearing Wall Demo.This permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-01-29Rough-InThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-01-29Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-02-19Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-03-21AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-04-14Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-04-21Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-07-15Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-09-15Shelter/PlatformThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-12-08Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2025-12-17Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2026-06-04New construction, addition, GFA changeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2026-06-22Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2026-07-10Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- L&I violation · 2022-12-27FIRE EXTINGUISHERSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27SUPPRESSION SYSTEM TESTING & MAINTENANCEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27SUBMISSION OF CERTIFICATIONSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27LABELINGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27UNAPPROVED CONDITIONSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27HIGH RISE BUILDINGSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27HIGH-RISE BUILDINGA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27HAZARD IDENTIFICATION SIGNSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27FIRE EXTINGUISHER SIZE & DISTRIBUTIONA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-12-27INSPECTION, TESTING AND MAINTENANCEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2023-06-14EXIT DOORSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2023-06-14ILLUMINATION EMERGENCY POWERA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2023-06-14EQUIPMENT ROOMSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2023-06-14ELEVATOR KEYSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2023-06-14DAMPER CERTIFICATION REPORTA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2023-07-14FACADESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2023-07-14L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- L&I violation · 2025-12-09BENCHMARKING LATEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2025-12-09L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-01-05L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-03-10L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-05-26L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-06-15L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-08-04L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-08-04L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-09-20L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-09-20L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2023-12-18L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2024-01-11L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2024-03-18L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2026-01-22L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- License · 2018-03-13SP Plus Corporation: Public Garage / Parking Lot business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2021-03-12SP Plus Corporation: Public Garage / Parking Lot business license marked closedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2013-01-07CBS RADIO EAST INC: Hazardous Materials L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2013-12-31CBS RADIO EAST INC: Hazardous Materials L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2011-03-30400 MARKET LP: High Rise L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2016-06-29400 MARKET LP: High Rise L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2010-02-12BINA'S INC (SUBWAY): Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2020-06-29BINA'S INC (SUBWAY): Food Preparing and Serving business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2007-04-05JONG SOO & HYON MI LEE: Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2005-11-23T/A QUIZNOS SUB LOPEZ ENTERPRIZE LLC: Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2012-12-22T/A QUIZNOS SUB LOPEZ ENTERPRIZE LLC: Food Preparing and Serving business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2012-12-22KISHAA FOOD INC: Food Preparing and Serving business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2012-12-22MICHAEL TAE B HAN (HANS LOBBY SHOP): Food Preparing and Serving business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2004-11-26KISHAA FOOD INC: Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2004-06-07MICHAEL TAE B HAN (HANS LOBBY SHOP): Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2003-07-24C S PACIFIC CAFE INC: Dumpster License - Public ROW L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2011-12-14C S PACIFIC CAFE INC: Dumpster License - Public ROW L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2003-07-17PACIFIC CAFE: Dumpster License - Private Property L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2010-10-12PACIFIC CAFE: Dumpster License - Private Property L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2003-07-11LUDLOW FOURTH CO: High Rise L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2004-04-30LUDLOW FOURTH CO: High Rise L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2003-02-27RICHARD I RUBIN & CO: Public Garage / Parking Lot business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2004-12-31RICHARD I RUBIN & CO: Public Garage / Parking Lot business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2002-11-15LUDLOW FOURTH COMPANY: Hazardous Materials L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2009-06-30LUDLOW FOURTH COMPANY: Hazardous Materials L&I license filing marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2002-09-04C S PACIFIC CAFE INC: Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2003-04-30C S PACIFIC CAFE INC: Food Preparing and Serving business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2003-04-30YI CHIN YONG: Food Preparing and Serving (30+ SEATS) business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2002-05-10YI CHIN YONG: Food Preparing and Serving (30+ SEATS) business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2000-04-20MICHAEL T HAN (T/A HAN'S LOBBY SHOP): Food Establishment, Retail Permanent Location business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2001-04-30MICHAEL T HAN (T/A HAN'S LOBBY SHOP): Food Establishment, Retail Permanent Location business license marked inactiveA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 1997-08-14DJJK INC: Dumpster License - Public ROW L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- Certification · 2012-03-28Facade ReportA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2018-06-05Facade ReportA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2022-06-01Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2022-06-01Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-05-10Facade ReportA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-06-05Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-06-05Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-06-05Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-06-05Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-06-05Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-08-08Emergency and Standby Power Systems CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2023-12-07Damper CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-04-12Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-04-12Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-04-12Sprinkler CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
- PermitAddition and/or Alteration
- PermitAddition and/or Alteration
- PermitNew construction, addition, GFA change
- InspectionL&I investigation
- PermitAddition and/or Alterations
- L&I violationBENCHMARKING LATE
- InspectionL&I investigation
- PermitAddition and/or Alteration
- PermitShelter/Platform
- PermitAddition and/or Alterations
- PermitAddition and/or Alteration
- PermitAddition and/or Alterations
- PermitAlterations
- PermitAddition and/or Alterations
- PermitRough-In
- PermitAddition and/or Alteration
- PermitInterior Non-Load-Bearing Wall Demo.
- PermitChange of Use
- CertificationSprinkler Certification
- CertificationFire Alarm Certification
- CertificationSprinkler Certification
- InspectionL&I investigation
- InspectionL&I investigation
- InspectionL&I investigation
- CertificationDamper Certification
- InspectionL&I investigation
- InspectionL&I investigation
- CertificationEmergency and Standby Power Systems Certification
- InspectionL&I investigation
- InspectionL&I investigation
- L&I violationFACADES
- InspectionL&I investigation
- InspectionL&I investigation
- L&I violationEXIT DOORS
- L&I violationILLUMINATION EMERGENCY POWER
- L&I violationEQUIPMENT ROOMS
- L&I violationELEVATOR KEYS
- L&I violationDAMPER CERTIFICATION REPORT
- CertificationSprinkler Certification
- CertificationFire Alarm Certification
- CertificationSprinkler Certification
- CertificationSprinkler Certification
- CertificationSprinkler Certification
- InspectionL&I investigation
- CertificationFacade Report
- InspectionL&I investigation
- InspectionL&I investigation
- L&I violationFIRE EXTINGUISHERS
- L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
- L&I violationSUBMISSION OF CERTIFICATIONS
- L&I violationLABELING
- L&I violationUNAPPROVED CONDITIONS
- L&I violationHIGH RISE BUILDINGS
- L&I violationHIGH-RISE BUILDING
- L&I violationHAZARD IDENTIFICATION SIGNS
- L&I violationFIRE EXTINGUISHER SIZE & DISTRIBUTION
- L&I violationINSPECTION, TESTING AND MAINTENANCE
- CertificationFire Alarm Certification
- CertificationFire Alarm Certification
- PermitAddition and/or Alteration
- PermitAddition and/or Alteration
- PermitAddition and/or Alterations
- PermitAddition and/or Alterations
- PermitAddition and/or Alterations
- PermitAddition and/or Alterations
- PermitAlterations
- PermitAlterations
- PermitAddition and/or Alteration
- PermitAddition and/or Alteration
- LicenseSP Plus Corporation: Public Garage / Parking Lot business license marked closed
- PermitInterior Non-Load-Bearing Wall Demo.
- PermitAddition and/or Alteration
- LicenseBINA'S INC (SUBWAY): Food Preparing and Serving business license marked inactive
- PermitAddition and/or Alteration
- PermitAddition and/or Alterations
- PermitNew Construction
- PermitAddition and/or Alterations
- PermitAlterations
- PermitRough-In
- PermitAddition and/or Alteration
- CertificationFacade Report
- LicenseSP Plus Corporation: Public Garage / Parking Lot business license initially issued
- License400 MARKET LP: High Rise L&I license filing marked inactive
- PermitNew Construction
- LicenseCBS RADIO EAST INC: Hazardous Materials L&I license filing marked inactive
- LicenseCBS RADIO EAST INC: Hazardous Materials L&I license filing initially issued
- LicenseT/A QUIZNOS SUB LOPEZ ENTERPRIZE LLC: Food Preparing and Serving business license marked inactive
- LicenseKISHAA FOOD INC: Food Preparing and Serving business license marked inactive
- LicenseMICHAEL TAE B HAN (HANS LOBBY SHOP): Food Preparing and Serving business license marked inactive
- CertificationFacade Report
- LicenseC S PACIFIC CAFE INC: Dumpster License - Public ROW L&I license filing marked inactive
- License400 MARKET LP: High Rise L&I license filing initially issued
- LicensePACIFIC CAFE: Dumpster License - Private Property L&I license filing marked inactive
- LicenseBINA'S INC (SUBWAY): Food Preparing and Serving business license initially issued
- LicenseLUDLOW FOURTH COMPANY: Hazardous Materials L&I license filing marked inactive
- LicenseJONG SOO & HYON MI LEE: Food Preparing and Serving business license initially issued
- LicenseT/A QUIZNOS SUB LOPEZ ENTERPRIZE LLC: Food Preparing and Serving business license initially issued
- LicenseRICHARD I RUBIN & CO: Public Garage / Parking Lot business license marked inactive
- LicenseKISHAA FOOD INC: Food Preparing and Serving business license initially issued
- LicenseMICHAEL TAE B HAN (HANS LOBBY SHOP): Food Preparing and Serving business license initially issued
- LicenseLUDLOW FOURTH CO: High Rise L&I license filing marked inactive
- LicenseC S PACIFIC CAFE INC: Dumpster License - Public ROW L&I license filing initially issued
- LicensePACIFIC CAFE: Dumpster License - Private Property L&I license filing initially issued
- LicenseLUDLOW FOURTH CO: High Rise L&I license filing initially issued
- LicenseC S PACIFIC CAFE INC: Food Preparing and Serving business license marked inactive
- LicenseYI CHIN YONG: Food Preparing and Serving (30+ SEATS) business license marked inactive
- LicenseRICHARD I RUBIN & CO: Public Garage / Parking Lot business license initially issued
- LicenseLUDLOW FOURTH COMPANY: Hazardous Materials L&I license filing initially issued
- LicenseC S PACIFIC CAFE INC: Food Preparing and Serving business license initially issued
- LicenseYI CHIN YONG: Food Preparing and Serving (30+ SEATS) business license initially issued
- LicenseMICHAEL T HAN (T/A HAN'S LOBBY SHOP): Food Establishment, Retail Permanent Location business license marked inactive
- LicenseMICHAEL T HAN (T/A HAN'S LOBBY SHOP): Food Establishment, Retail Permanent Location business license initially issued
- LicenseDJJK INC: Dumpster License - Public ROW L&I license filing initially issued
Verify the public record
Property tax
$139,980/year estimated property tax
2026 taxable assessment $10,000,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.
OPA has published a 2027 assessment of $58,880,800. It is not the 2026 billed-year value.
Payments, credits, interest, and the current amount due are maintained by the City.
OPA 8810013362026 taxable assessment equals the full assessed value.
Historical delinquency sources No current conclusion
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Building report
Apartment building
Apartments, recorded in the City's apartments category. The public record and owner trail follow.
10 open violations
Recorded owner
Who's behind it
Lak Market Master Htc Landlord LLC · corporate / LLC owner
• Tax bills mail to C/O Keystone Development + Investment 1001 Conshohocken State Road Suite 1-401, West Conshohocken PA, 19428 — outside Philadelphia
Block context
400 block of Market St. Compare parcels, ownership, and public-record history.
See the whole block →L&I license dates · data through Jul 25, 2026
Business licenses at this address Latest pull
What L&I has registered at this OPA parcel, newest initial license date first.
Public Garage / Parking Lot · Initial issue date Mar 13, 2018 · Terminal license date Mar 12, 2021
Food Preparing and Serving · Initial issue date Feb 12, 2010 · Terminal license date Jun 29, 2020
Food Preparing and Serving · Initial issue date Apr 5, 2007 · Filed expiration Apr 30, 2027
Food Preparing and Serving · Initial issue date Nov 23, 2005 · Terminal license date Dec 22, 2012
Food Preparing and Serving · Initial issue date Nov 26, 2004 · Terminal license date Dec 22, 2012
Food Preparing and Serving · Initial issue date Jun 7, 2004 · Terminal license date Dec 22, 2012
Public Garage / Parking Lot · Initial issue date Feb 27, 2003 · Terminal license date Dec 31, 2004
Food Preparing and Serving · Initial issue date Sep 4, 2002 · Terminal license date Apr 30, 2003
Food Preparing and Serving (30+ SEATS) · Initial issue date May 10, 2002 · Terminal license date Apr 30, 2003
Food Establishment, Retail Permanent Location · Initial issue date Apr 20, 2000 · Terminal license date Apr 30, 2001
A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.
Open every source row 114 dated rows
- PermitAddition and/or Alteration
Permit EP-2026-005876 · Completed
Provide new electrical work to support installation of a one-stop elevator including branch circuit wiring, lighting, and associated fire alarm modifications at elevator and rooftop equipment per APPROVED plans, NEC 2017 & 2016 NFPA 72.
- PermitAddition and/or Alteration
Permit CP-2026-001510 · Issued
LEVEL II EXTERIOR ALTERATIONS TO INCLUDE RENOVATIONS TO BUILDING ENTRY AREA AND ROOF LEVEL TO CREATE ROOF DECKS AND DOG PARK AND TO EXTEND ELEVATOR TO ROOF LEVEL AS PER APPROVED PLANS. SEE PERMIT CP-2024-006451 FOR BASE BUILDING WORK. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW*
- PermitNew construction, addition, GFA change
Permit ZP-2026-003813 · Issued
Addition of roof decks and elevator to existing structure as per approved plan. Access to proposed roof decks from existing stairwells only. Roof access of any kind from proposed elevator is STRICTLY PROHIBITED and is not associated with this permit.
- InvestigationL&I investigation
Case CF-2025-131900 · PASSED
The cited inspection visit was marked passed.
- PermitAddition and/or Alterations
Permit FP-2025-002292 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 45 existing sprinkler heads, per NFPA 13
- ViolationBENCHMARKING LATE
Case CF-2025-131900 · Violation VI-2025-095528 · Code 9-3402(2) · CLOSED
Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.
- InvestigationL&I investigation
Case CF-2025-131900 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitAddition and/or Alteration
Permit EP-2025-011669 · Completed
Install cabling and equipment for access control and cctv systems
- PermitShelter/Platform
Permit GP-2025-008233 · Completed
Erection of a sidewalk shelter platform as per Engineered Plans. Streets Department permit is required for sidewalk closure prior to the start work.
- PermitAddition and/or Alterations
Permit FP-2025-001441 · Completed
FOR A FIRE PUMP REPLACEMENT PER APPROVED PLANS .ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA
- PermitAddition and/or Alteration
Permit EP-2025-001795 · Completed
Provide temporary power and lighting as required. Temporary lighting for individual units is excluded. Furnish and install new distribution system, lighting and light controls, branch wiring throughout all BOH, amenity, and common spaces. Furnish and install all lighting, branch circuit wiring, receptacles, switches, 120V smoke/CO alarms, appliance handling, and CATV/Data jack in each living room and bedroom of residential units. Install a two-way communication system in elevator lobbies. Install low voltage conduits {(3) 4" sleeves through Telecom Closets for future utility risers} as per 2017 NEC. Install fire alarm system as per 2016 NFPA 72.
- PermitAddition and/or Alterations
Permit MP-2025-001091 · Completed
FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, AND ASSOCIATED DUCTWORK AND A STAIRWAY ENCLOSURE PRESSURIZATION SYSTEM THROUGHOUT A MULTI-FAMILY OCCUPANCY WITHIN THE EXISTING HIGH-RISE BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC AND APPLIANCE MANUFACTURER SPECIFICATIONS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE CP-2024-006451 FOR ASSOCIATED BUILDING PERMIT.
- PermitAlterations
Permit PP-2025-000885 · Completed
INSTALL 176 KITCHEN SINKS, 176 WASHING MACHINE BOXES, 14 FLOOR DRAINS, 176 EMERGENCY FLOOR DRAINS, 5 ROOF DRAINS, 4 AREA DRAINS, 7 INDIRECT WASTE RECEPTORS, 1 DOMESTIC BOOSTER PUMP, 176 HOT WATER HEATERS, 204 WATER CLOSETS, 204 LAVATORIES AND 204 SHOWER/TUBS ACCORDING TO THE 2018 PPC AND PER PLANS.
- PermitAddition and/or Alterations
Permit FP-2025-000230 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 500 sprinklers to ensure the safety of the building per NFPA 13
- PermitRough-In
Permit PP-2025-000887 · Completed
Rough-In Permit for PP-2025-000885 Complete sanitary, waste and vent system; complete domestic water system; Install plumbing fixtures and water heaters; other equipment = washing machine box - quantity 176
- PermitAddition and/or Alteration
Permit CP-2024-006451 · Completed
LEVEL III ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE ONE HUNDRED SEVENTY-SIX (176) DWELLING UNITS ON THE SECOND THROUGH TWELFTH FLOORS OF AN EXISTING HIGH-RISE BUILDING WITH ACCESSORY AMENITY SPACES ON THE GROUND FLOOR AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED WITH STANDPIPES. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**
- PermitInterior Non-Load-Bearing Wall Demo.
Permit GM-2024-006682 · Completed
EZ INTERIOR NON-LOAD-BEARING WALL DEMOLITION - For the interior demolition on NON-Load-Bearing partition walls and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans
- PermitChange of Use
Permit ZP-2024-008718 · Issued
Residential - Household Living - Multi-Family
- CertificationSprinkler Certification
Certification BC-2024-018649 · Deficient
- CertificationFire Alarm Certification
Certification BC-2024-015902 · Certified
Expires 2025-04-12
- CertificationSprinkler Certification
Certification BC-2024-021689 · Certified
Expires 2025-04-12
- InvestigationL&I investigation
Case CF-2023-000961 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2023-056940 · PASSED
The cited inspection visit was marked passed.
- InvestigationL&I investigation
Case CF-2023-066764 · PASSED
The cited inspection visit was marked passed.
- CertificationDamper Certification
Certification BC-2023-026268 · Certified
Expires 2027-12-07
- InvestigationL&I investigation
Case CF-2023-000961 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2023-056940 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- CertificationEmergency and Standby Power Systems Certification
Certification BC-2023-020853 · Certified
Expires 2024-08-08
- InvestigationL&I investigation
Case CF-2023-000961 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2023-056940 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationFACADES
Case CF-2023-066764 · Violation VI-2023-050305 · Code PM15-315.2 · COMPLIED
Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationL&I investigation
Case CF-2023-066764 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2023-056940 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationEXIT DOORS
Case CF-2023-056940 · Violation VI-2023-042803 · Code F-1104.28 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationILLUMINATION EMERGENCY POWER
Case CF-2023-056940 · Violation VI-2023-042805 · Code F-1104.5 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationEQUIPMENT ROOMS
Case CF-2023-056940 · Violation VI-2023-042807 · Code F-315.3.3 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationELEVATOR KEYS
Case CF-2023-056940 · Violation VI-2023-042812 · Code F-606.7 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationDAMPER CERTIFICATION REPORT
Case CF-2023-056940 · Violation VI-2023-042815 · Code F-701.6.1.5 · COMPLIED
Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- CertificationSprinkler Certification
Certification BC-2024-002825 · Certified
Expires 2024-06-05
- CertificationFire Alarm Certification
Certification BC-2023-012417 · Certified
Expires 2024-06-05
- CertificationSprinkler Certification
Certification BC-2023-016114 · Deficient
- CertificationSprinkler Certification
Certification BC-2023-016513 · Deficient
- CertificationSprinkler Certification
Certification BC-2023-016515 · Deficient
- InvestigationL&I investigation
Case CF-2023-000961 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- CertificationFacade Report
Certification BC-2023-025492 · Safe with Repair
Expires 2028-05-10
- InvestigationL&I investigation
Case CF-2023-000961 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationL&I investigation
Case CF-2023-000961 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- ViolationFIRE EXTINGUISHERS
Case CF-2023-000961 · Violation VI-2023-000617 · Code F-906.2 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE
Case CF-2023-000961 · Violation VI-2023-000634 · Code F-903.5 · COMPLIED
Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationSUBMISSION OF CERTIFICATIONS
Case CF-2023-000961 · Violation VI-2023-000635 · Code F-901.6.4.2 · COMPLIED
Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationLABELING
Case CF-2023-000961 · Violation VI-2023-000636 · Code F-604.3.1 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationUNAPPROVED CONDITIONS
Case CF-2023-000961 · Violation VI-2023-000641 · Code F-604.6 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationHIGH RISE BUILDINGS
Case CF-2023-000961 · Violation VI-2023-000653 · Code F-403.11.2 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationHIGH-RISE BUILDING
Case CF-2023-000961 · Violation VI-2023-000654 · Code F-105.6.3 · OPEN
The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.
- ViolationHAZARD IDENTIFICATION SIGNS
Case CF-2023-000961 · Violation VI-2023-000656 · Code F-5003.5 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationFIRE EXTINGUISHER SIZE & DISTRIBUTION
Case CF-2023-000961 · Violation VI-2023-000658 · Code F-906.3 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationINSPECTION, TESTING AND MAINTENANCE
Case CF-2023-000961 · Violation VI-2023-000662 · Code F-907.8.5 · COMPLIED
Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.
- CertificationFire Alarm Certification
Certification BC-2022-010703 · Certified
Expires 2023-06-01
- CertificationFire Alarm Certification
Certification BC-2022-010660 · Certified
Expires 2023-06-01
- PermitAddition and/or Alteration
Permit EP-2022-003428 · Completed
Furnish and Install new metal-clad branch circuits as needed. Furnish MC Cabling for open ceiling fixtures. Installation lighting fixtures. Installation lighting controls. Furnish and install switches, outlets & 1" stub ups for tele/data. Installation of fire alarm equipment. . Conference room floor box & coring. Termination of all new branch circuits wiring in existing panel board. ALL WORK IS TO DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.
- PermitAddition and/or Alteration
Permit EP-2022-003432 · Completed
Furnish and Install new metal-clad branch circuits as needed. Furnish MC Cabling for open ceiling fixtures. Installation lighting fixtures. Installation of lighting controls. Furnish and install switches, outlets & 1" stub ups for tele/data. Installation of fire alarm equipment. Conference room floor box & coring. Termination of all new branch circuits wiring in existing panel board. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.
- PermitAddition and/or Alterations
Permit MP-2022-001905 · Completed
FOR THE INSTALLATION OF A NEW HVAC SYSTEM INCLUDING NEW DUCTWORK, NEW DIFUSERS AND RETURN AIR GRILLES AS PER PLANS.
- PermitAddition and/or Alterations
Permit FP-2022-001064 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (16) Sprinkler Heads in suite 350 (CP-2021-009311)
- PermitAddition and/or Alterations
Permit FP-2022-001063 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (24) Sprinkler Heads in suite 600 (CP-2021-009317)
- PermitAddition and/or Alterations
Permit MP-2022-001874 · Completed
ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMMODATE NEW OFFICE LAYOUT IN SUITE 350 ON THE 3RD FLOOR OF AN EXISTING OFFICE BUILDING AS PER APPROVED PLANS.
- PermitAlterations
Permit PP-2022-004798 · Completed
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.
- PermitAlterations
Permit PP-2022-004806 · Completed
Furnish and install [1] Sink [1] Water Filter, [1] Hot Water Heater,[2] appliance supply boxes AS PER PPC 2018
- PermitAddition and/or Alteration
Permit CP-2021-009311 · Completed
FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE (SUITE 350) FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
- PermitAddition and/or Alteration
Permit CP-2021-009317 · Completed
FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE (SUITE 600) FOR USE AS A BUSINESS OCCUPANCY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT THE DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
- License terminal eventSP Plus Corporation: Public Garage / Parking Lot business license marked closed
License 769080 · Closed
License event. Registration does not prove present operation or storefront occupancy.
- PermitInterior Non-Load-Bearing Wall Demo.
Permit GM-2020-007649 · Expired
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.
- PermitAddition and/or Alteration
Permit EP-2020-006713 · Completed
Run 25 network lines with a patch panel for office internet as per 2017 nec.
- License terminal eventBINA'S INC (SUBWAY): Food Preparing and Serving business license marked inactive
License 493508 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitAddition and/or Alteration
Permit EP-2020-000817 · Completed
Fire alarm for tenant fit-out, as per Drawing. '17 NEC and '16 NFPA-72.
- PermitAddition and/or Alterations
Permit FP-2020-000313 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. (Alterations permit #1044153) Relocating (36) sprinklers at LifeStance Suite 720
- PermitNew Construction
Permit 1055583 · Completed
TENANT FIT OUT INCLUDING LIGHTING AND GENERAL RECEPTACLES PER 2017 NEC (CC DIST)
- PermitAddition and/or Alterations
Permit MP-2020-000292 · Completed
ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMMODATE NEW OFFICE LAYOUT IN SUITE 720 ON THE 7TH FLOOR OF AN EXISTING OFFICE BUILDING AS PER APPROVED PLANS.
- PermitAlterations
Permit PP-2020-000705 · Completed
Installation of listed fixtures per 2018 Philadelphia Plumbing Code.
- PermitRough-In
Permit 1055583-RI · Completed
TENANT FIT OUT INCLUDING LIGHTING AND GENERAL RECEPTACLES PER 2017 NEC (CC DIST)
- PermitAddition and/or Alteration
Permit 1044153 · Completed
**ASBESTOS REMOVAL REQUIRED PRIOR TO START OF WORK** FOR PRESCRIPTIVE ALTERATIONS (WITHOUT A CHANGE OF OCCUPANCY) TO SUITE #720 (LIFESTANCE HEALTH) ON THE 7TH FLR OF AN EXISTING HIGH-RISE OFFICE BUILDING, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING FULLY SPRINKLERED; NO CHANGES TO EXISTING DEMISING WALLS OR COMMON AREAS.
- CertificationFacade Report
Certification BC-2022-002124 · Safe with Repair
Expires 2023-06-05
- License issue eventSP Plus Corporation: Public Garage / Parking Lot business license initially issued
License 769080 · Closed
License event. Registration does not prove present operation or storefront occupancy.
- License terminal event400 MARKET LP: High Rise L&I license filing marked inactive
License 528956 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitNew Construction
Permit 555469 · Expired
INSTALL COMMUNICATIONS CABLING, CAT 5e FOR 1 NEW ATM, INSTALL 120V POWER FOR 1 NEW ATM, CARD CONNECTED, INSTALL 4 NEW RECESSED COMPACT FLOURESCENT LIGHTING FIXTURES AS PER 2008 NEC (CC DISTRICT)
- License terminal eventCBS RADIO EAST INC: Hazardous Materials L&I license filing marked inactive
License 575479 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventCBS RADIO EAST INC: Hazardous Materials L&I license filing initially issued
License 575479 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventT/A QUIZNOS SUB LOPEZ ENTERPRIZE LLC: Food Preparing and Serving business license marked inactive
License 346490 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventKISHAA FOOD INC: Food Preparing and Serving business license marked inactive
License 208322 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventMICHAEL TAE B HAN (HANS LOBBY SHOP): Food Preparing and Serving business license marked inactive
License 205611 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- CertificationFacade Report
Certification BC-2022-009621 · Safe with Repair
Expires 2017-03-28
- License terminal eventC S PACIFIC CAFE INC: Dumpster License - Public ROW L&I license filing marked inactive
License 298252 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue event400 MARKET LP: High Rise L&I license filing initially issued
License 528956 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventPACIFIC CAFE: Dumpster License - Private Property L&I license filing marked inactive
License 279277 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventBINA'S INC (SUBWAY): Food Preparing and Serving business license initially issued
License 493508 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventLUDLOW FOURTH COMPANY: Hazardous Materials L&I license filing marked inactive
License 285725 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventJONG SOO & HYON MI LEE: Food Preparing and Serving business license initially issued
License 405702 · Active
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventT/A QUIZNOS SUB LOPEZ ENTERPRIZE LLC: Food Preparing and Serving business license initially issued
License 346490 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventRICHARD I RUBIN & CO: Public Garage / Parking Lot business license marked inactive
License 284821 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventKISHAA FOOD INC: Food Preparing and Serving business license initially issued
License 208322 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventMICHAEL TAE B HAN (HANS LOBBY SHOP): Food Preparing and Serving business license initially issued
License 205611 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventLUDLOW FOURTH CO: High Rise L&I license filing marked inactive
License 299009 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventC S PACIFIC CAFE INC: Dumpster License - Public ROW L&I license filing initially issued
License 298252 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventPACIFIC CAFE: Dumpster License - Private Property L&I license filing initially issued
License 279277 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventLUDLOW FOURTH CO: High Rise L&I license filing initially issued
License 299009 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventC S PACIFIC CAFE INC: Food Preparing and Serving business license marked inactive
License 205620 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventYI CHIN YONG: Food Preparing and Serving (30+ SEATS) business license marked inactive
License 209885 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventRICHARD I RUBIN & CO: Public Garage / Parking Lot business license initially issued
License 284821 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventLUDLOW FOURTH COMPANY: Hazardous Materials L&I license filing initially issued
License 285725 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventC S PACIFIC CAFE INC: Food Preparing and Serving business license initially issued
License 205620 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventYI CHIN YONG: Food Preparing and Serving (30+ SEATS) business license initially issued
License 209885 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License terminal eventMICHAEL T HAN (T/A HAN'S LOBBY SHOP): Food Establishment, Retail Permanent Location business license marked inactive
License 199437 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventMICHAEL T HAN (T/A HAN'S LOBBY SHOP): Food Establishment, Retail Permanent Location business license initially issued
License 199437 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- License issue eventDJJK INC: Dumpster License - Public ROW L&I license filing initially issued
License 296985 · Inactive
License event. Registration does not prove present operation or storefront occupancy.
- PermitNew construction, addition, GFA change
Permit ZP-2025-010864 · Denied
Where this comes from
- Assessment, spec sheet & owner: OPA Property Assessments, Office of Property Assessment
- Sales & deed history: Realty Transfer Tax records, Recorder of Deeds
- Permits, violations & inspections: L&I Property History · Atlas
- Tax delinquency snapshot · June 2022: Real Estate Tax Delinquencies, Dept. of Revenue
- Historical tax ledger & liens · through 2016: Real Estate Tax Balances, Dept. of Revenue
- Current property-tax balance: Verify with Philadelphia Revenue
- Zoning appeals: L&I & Zoning Board appeals
- Neighborhood income & rents: US Census ACS 5-year estimates
- Historical mortgage rates: Freddie Mac Primary Mortgage Market Survey, annual averages
- Imagery: Street photo © Google · Aerial © Esri, Maxar
Methodology & freshness
This report was assembled Jul 26, 2026, 7:29 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)