Commercial property report
400 South St
4 stories3,895 sqftCMX3built 1900
Mckl Properties LP
Assessment and City record timeline
The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.
Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $1,255,400. It is not yet the billed-year tax basis.
- OPA assessment · 2016$657K assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2017$657K assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2018$1.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2019$1.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2020$1.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2021$1.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2022$1.2M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2023$1.3M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2024$1.3M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2025$1.4M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2026$1.4M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- OPA assessment · 2027$1.3M assessed valueOPA’s value on the City tax roll for that year. It is not an appraisal, listing price, sale price, or live tax balance.How Philadelphia property assessments work ↗
- Permit · 2013-10-07ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2014-11-13ElectricalThis permit category usually covers electrical installation, alteration, replacement, or repair. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2015-02-09Major alterationA broad legacy permit work category for a substantial building alteration. It can include changed layouts, partitions, fixtures, finishes, structural work, or occupancy-related work, but only the approved scope and plans say what this permit actually authorized; separate trade permits may be required.What Philadelphia building permits can cover ↗
- Permit · 2016-08-09Zoning/useThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2016-12-01SignThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2020-03-02AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-12-19Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2022-12-30Interior Non-Load-Bearing Wall Demo.This permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Inspection · 2022-12-30L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Permit · 2023-04-04New construction, addition, GFA changeThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-05-26Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-07-28Change of UseThis permit category usually covers the property’s allowed use, dimensions, occupancy, or site configuration. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-09-05Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-09-25AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-10-24Rough-InThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2023-11-14Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-01-22AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-01-22Addition and/or AlterationThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-02-17Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-03-05Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- Permit · 2024-03-15Addition and/or AlterationsThis permit category usually covers construction, repair, alteration, addition, or occupancy work. The approved scope—not the short category—defines what was authorized, and issuance alone does not prove completion.Philadelphia construction and repair permits ↗
- L&I violation · 2007-08-28VIOL BC MESSAGEA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2007-08-28BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- L&I violation · 2015-08-15EXTERIOR STRUCT DEC FEATURESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2015-08-15HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- L&I violation · 2022-07-29UNSAFE STRUCTUREA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-07-29EXTERIOR WALLSA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-07-29ROOF DEFICIENCIESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-07-29INTERIOR UNSAFE GENERALA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- L&I violation · 2022-07-29ARCHITECT/ENGINEER SERVICESA dated L&I enforcement row. Read the cited code, required correction, status, and later inspections together; the title alone does not establish the property’s current condition.How L&I violations and orders work ↗
- Inspection · 2022-07-29L&I investigationA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2006-01-27BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2006-06-05BC INSP (likely: building-code inspection)Legacy inspection shorthand; confirm the inspection type and scope in the City case file.What Philadelphia inspections check ↗
- Inspection · 2006-09-27HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2006-09-27HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- Inspection · 2006-11-01CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2006-12-01CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2007-01-08CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2007-01-29CI INSPA dated L&I visit or review. Its type describes the inspection program; the separate result and later rows show whether that visit passed, failed, or led to follow-up.What Philadelphia inspections check ↗
- Inspection · 2015-08-25HCEU INSP (Housing Code Enforcement Unit inspection)A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended.What Philadelphia inspections check ↗
- License · 2019-02-15400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving (30+ SEATS) business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2006-03-03400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving business license initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2018-04-30400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving business license marked closedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- License · 2004-04-09400 SOUTH CORP (JIMS STEAKS): Dumpster License - Public ROW L&I license filing initially issuedA City license record tied to an activity or property use. Its issue, expiration, inactive, and status fields—not the category alone—show what was recorded for this date.Philadelphia L&I licenses and property records ↗
- Certification · 2022-01-25Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2022-05-22Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-04-22Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-04-22Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2024-11-30Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-04-29Fire Alarm CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2025-05-31Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Certification · 2026-05-31Special Hazards CertificationA filed inspection or certification for a regulated building system or component. Check the result, expiration date, and latest filing before treating it as current.What Philadelphia inspections check ↗
- Appeal · 2016-06-29Zoning board appealA challenge or request reviewed through a City appeals process. Filing an appeal does not show who prevailed; read the decision, conditions, and related permit or violation.How Philadelphia L&I appeals work ↗
Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
- CertificationSpecial Hazards Certification
- CertificationSpecial Hazards Certification
- CertificationFire Alarm Certification
- CertificationSpecial Hazards Certification
- CertificationFire Alarm Certification
- CertificationFire Alarm Certification
- PermitAddition and/or Alterations
- PermitAddition and/or Alterations
- PermitAddition and/or Alterations
- PermitAlterations
- PermitAddition and/or Alteration
- PermitAddition and/or Alterations
- PermitRough-In
- PermitAlterations
- PermitAddition and/or Alteration
- PermitChange of Use
- PermitAddition and/or Alteration
- PermitNew construction, addition, GFA change
- PermitInterior Non-Load-Bearing Wall Demo.
- InspectionL&I investigation
- PermitAddition and/or Alteration
- L&I violationUNSAFE STRUCTURE
- L&I violationEXTERIOR WALLS
- L&I violationROOF DEFICIENCIES
- L&I violationINTERIOR UNSAFE GENERAL
- L&I violationARCHITECT/ENGINEER SERVICES
- InspectionL&I investigation
- CertificationFire Alarm Certification
- CertificationSpecial Hazards Certification
- PermitAlterations
- License400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving (30+ SEATS) business license initially issued
- License400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving business license marked closed
- PermitSign
- PermitZoning/use
- AppealZoning board appeal
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- L&I violationEXTERIOR STRUCT DEC FEATURES
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- PermitMajor alteration
- PermitElectrical
- PermitElectrical
- L&I violationVIOL BC MESSAGE
- InspectionBC INSP (likely: building-code inspection)
- InspectionCI INSP
- InspectionCI INSP
- InspectionCI INSP
- InspectionCI INSP
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
- InspectionBC INSP (likely: building-code inspection)
- License400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving business license initially issued
- InspectionBC INSP (likely: building-code inspection)
- License400 SOUTH CORP (JIMS STEAKS): Dumpster License - Public ROW L&I license filing initially issued
Verify the public record
Property tax
$19,047/year estimated property tax
2026 taxable assessment $1,360,700 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.
OPA has published a 2027 assessment of $1,255,400. It is not the 2026 billed-year value.
Payments, credits, interest, and the current amount due are maintained by the City.
OPA 8826361002026 taxable assessment equals the full assessed value.
Historical delinquency sources No current conclusion
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Where the record looks off
Conflicts in City paperwork. Flags on the data, not the property.
Philadelphia records use 1900 as a stand-in when the real construction year was never documented. Treat the age as unknown, not as 120+ years.
Property report
Commercial property
Commercial, recorded in the City's commercial category. The public record and owner trail follow.
Recorded owner
Who's behind it
Mckl Properties LP · corporate / LLC owner
• Tax bills mail to 400 South St, Philadelphia PA, 19147
Block context
400 block of South St. Compare parcels, ownership, and public-record history.
See the whole block →Next door: 402 South St · 404 South St
L&I license dates · data through Jul 24, 2026
Business licenses at this address Latest pull
What L&I has registered at this OPA parcel, newest initial license date first.
Food Preparing and Serving (30+ SEATS) · Initial issue date Feb 15, 2019 · Filed expiration Feb 14, 2027
Food Preparing and Serving · Initial issue date Mar 3, 2006 · Terminal license date Apr 30, 2018
A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.
Open every source row 53 dated rows
- CertificationSpecial Hazards Certification
Certification BC-2026-015849 · Certified
Expires 2027-05-31
- CertificationSpecial Hazards Certification
Certification BC-2025-014786 · Certified
Expires 2026-05-31
- CertificationFire Alarm Certification
Certification BC-2025-012555 · Certified
Expires 2026-04-29
- CertificationSpecial Hazards Certification
Certification BC-2024-032336 · Certified
Expires 2025-11-30
- CertificationFire Alarm Certification
Certification BC-2024-011187 · Certified
Expires 2025-04-22
- CertificationFire Alarm Certification
Certification BC-2024-011254 · Certified
Expires 2025-04-22
- PermitAddition and/or Alterations
Permit FP-2024-000510 · Completed
EZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. Install UL300 kitchen fire suppression system
- PermitAddition and/or Alterations
Permit MP-2024-000800 · Completed
FOR THE INSTALLATION OF A TYPE 1 COMMERCIAL KITCHEN HOOD (13'-0") AND ASSOCIATED DUCTWORK, FANS AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ELECTRICAL AND FIRE SUPPRESSION WORK. **IMC 2018**
- PermitAddition and/or Alterations
Permit MP-2024-000503 · Completed
FOR THE INSTALLATION OF NEW FUEL GAS PIPPING AS PER PLANS. FOR THE INSTALLATION OF A NEW HVAC SYSTEM INCLUDING MECHANICAL APPLIANCES, REGISTERS AND DIFFUSERS WITH ASSOCIATED DUCTWORK AND ACCESSORIES AS PER PLANS. A SEPARATE PERMIT WILL BE REQUIRED FOR THE INSTALLATION OF THE COMMERCIAL KITCHEN EXHAUST HOOD. SEE PERMIT MP-2024-000503 FOR MECHANICAL WORK AT 402 SOUTH ST.
- PermitAlterations
Permit PP-2023-016072 · Completed
REPAIR/REPLACE 4" WDP.
- PermitAddition and/or Alteration
Permit EP-2023-011870 · Completed
NEW WIRE THRU OUT LIGHTING OUTLETS SWITCHES INSTALL 400 AMP SERVICE AS PER PLANS GROUNDING AND BONDING AS PER PLANS INSTALL NEW FIRE ALARM SYSTEM . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72. AMENDMENT:PECO COULD NOT SUPPLY 2 PHASE 5 WIRE SERVICE : 200 AMP 3 PHASE SERVICE IS BEING INSTALLED PER APPROVED DRAWINGS-2017 NEC.
- PermitAddition and/or Alterations
Permit FP-2023-002522 · Completed
COMBINED AUTOMATIC SPRINKLER & CLASS I MANUAL WET STANDPIPE SYSTEMS WITH FOUR (4) INCH FIRE SERVICE LINE & BACKFLOW PREVENTION (BFP) ASSEMBLY AS PER APPROVED PLANS. AUTOMATIC SPRINKLER SYSTEM & STANDPIPE SYSTME INSTALLATION PER NFPA 13/14.
- PermitRough-In
Permit FP-2023-002527 · Completed
Rough-In Permit for FP-2023-002522 INSTALLATION OF A FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13
- PermitAlterations
Permit PP-2023-011119 · Completed
New kitchen in basement and 1st floor. Install 1 three bay sink in basement kitchen & mop sink, 2 prep-sinks, 3 hand sinks. Two lav sinks. Four floor sinks & 1 floor drain. New grease trap. Garbage disposal in basement. Two toilets, 1 on 1st floor, 1 on 2nd floor. New bathroom on 1st floor and new bathroom on 2nd floor. All new main drains and stacks, all new water main (interior).
- PermitAddition and/or Alteration
Permit CP-2023-004534 · Completed
FOR LEVEL 3 ALTERATIONS TO AN EXISTING THREE STORY STRUCTURE AS PER PLAN. THE FOURTH STORY ATTIC SPACE MUST BE SEALED OF WITH FIRE DEPARTMENT ACCESS ONLY. ALTERATIONS FOR A CHANGE IN OCCUPANCY CLASSIFICATION TO RESTAURANT SPACE.
- PermitChange of Use
Permit ZP-2023-007715 · Issued
Eating and Drinking Establishments - Sit-Down Restaurant
- PermitAddition and/or Alteration
Permit CP-2023-001997 · Completed
FOR LEVEL III ALTERATIONS, ADDITION AND PARTIAL CHANGE IN OCCUPANCY (B TO A-2; HIGHER HAZARD CATEGORY) ON THE FIRST AND SECOND FLOOR LEVEL. STRUCTURE FOR USE AS A SIT DOWN RESTAURANT ON THE FIRST THROUGH SECOND FLOOR WITH ACCESSORY PREP IN BASEMENT AS PREVIOUSLY APPROVED AND ACCESSORY STORAGE FROM THE THIRD THROUGH FOURTH FLOOR LEVEL. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13. ALTERATIONS TO INCLUDE THE REBUILDING OF CERTAIN PORTIONS OF BUILDING THAT WAS DAMAGED DUE TO A FIRE. ALTERATIONS TO ALSO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, ACCESSIBILITY IMPROVEMENTS AND STRUCTURAL WORK AS SHOWN PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. *AMEND 4-24-24 - REVISE STATEMENT OF SPECIAL INSPECTION SCHEDULE*
- PermitNew construction, addition, GFA change
Permit ZP-2023-001132 · Completed
FOR THE ERECTION OF REBUILDING OF PORTIONS OF A DESTROYED BUILDING BY FIRE; FOR THE ERECTION OF AN ADDITION TO THE SECOND FLOOR ( The extension of addition and use is not more than 10% of the existing building) OF AN EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN IN THE APPLICATION.
- PermitInterior Non-Load-Bearing Wall Demo.
Permit GM-2022-011235 · Expired
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.
- InvestigationL&I investigation
Case CF-2022-076205 · PASSED
The cited inspection visit was marked passed.
- PermitAddition and/or Alteration
Permit CP-2022-006795 · Completed
MAKE SAFE PERMIT TO COMPLY WITH CF-2022-076205 TO INCLUDE REPAIRS/REPLACEMENT OF ROOF AND FRAMING PER APPROVED PLANS AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. SEPARATE PERMITS REQUIRED FOR ADDITIONAL ALTERATIONS NOT ADDRESSED IN APPROVED PLANS.
- ViolationUNSAFE STRUCTURE
Case CF-2022-076205 · Violation VI-2022-055646 · Code PM15-108.1 · COMPLIED
Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationEXTERIOR WALLS
Case CF-2022-076205 · Violation VI-2022-055647 · Code PM15-304.1(G) · COMPLIED
Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationROOF DEFICIENCIES
Case CF-2022-076205 · Violation VI-2022-055648 · Code PM15-304.1(H) · COMPLIED
Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationINTERIOR UNSAFE GENERAL
Case CF-2022-076205 · Violation VI-2022-055649 · Code PM15-305.1 · COMPLIED
Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- ViolationARCHITECT/ENGINEER SERVICES
Case CF-2022-076205 · Violation VI-2022-055650 · Code A-304.1/1 · COMPLIED
Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationL&I investigation
Case CF-2022-076205 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- CertificationFire Alarm Certification
Certification BC-2022-011142 · Certified
Expires 2023-05-22
- CertificationSpecial Hazards Certification
Certification BC-2022-001966 · Certified
Expires 2023-01-25
- PermitAlterations
Permit 1054058 · Expired
REPLACE MAIN DRAIN, CURB TRAP & FAI PA20200582054 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
- License issue event400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving (30+ SEATS) business license initially issued
License 802704 · Active
License event. Registration does not prove present operation or storefront occupancy.
- License terminal event400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving business license marked closed
License 358392 · Closed
License event. Registration does not prove present operation or storefront occupancy.
- PermitSign
Permit 713722 · COMPLETED
FOR THE INSTALLATION OF SIGNS ACCESSORY TO EXISTING TAKEOUT RESTAURANT IN AN EXISTING BUILDING. ALL CONNECTION DETAILS TO BE DONE IN ACCORDANCE WITH APPROVED PLANS AND DETAILS SIGNED BY STRUCTURAL ENGINEER. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.
- PermitZoning/use
Permit 693936 · COMPLETED
AMENDED APPLICATION (A/P # 612338); FOR THE ERECTION OF ONE (1) ACCESSORY DOUBLE FACED PROJECTING SIGN, THREE (3) ACCESSORY FLAT WALL SIGNS AND TWO (2) ACCESSORY WINDOW SIGNS (NOT TO EXCEED 20% OF THE TOTAL GLAZED AREA OF ALL WINDOWS AND DOORS ON THAT FLOOR) (SIZE AND LOCATION AS SHOWN IN THE APPLICATION)ALL ACCESSORY TO AN EXISTING TAKE OUT RESTAURANT ON 1ST AND 2ND FLOORS AS PREVIOUSLY APPROVED WITH VACANT 3RD AND 4TH FLOORS (USE REGISTRATION PERMIT REQUIRE PRIOR TO OCCUPANCY) (SIZE AND LOCATION AS SHOWN IN THE APPLICATION).
- AppealZoning board appeal
Appeal 25774 · CLOSED · Granted
Related permit 693936 · PERMIT FOR THE ERECTION OF ONE (1) ACCESSORY DOUBLE FACED PROJECTING SIGN, LEGALIZATION OF THE ERECTION OF TWO (2) ACCESSORY FLAT WALL SIGNS AND TWO (2) ACCESSORY WINDOW SIGNS ALL ACCESSORY TO AN EXISTING TAKE OUT RESTAURANT ON 1ST AND 2ND
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 497614 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
- ViolationEXTERIOR STRUCT DEC FEATURES
Case 497614 · Violation 3678189 · Code PM15-304.8 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 497614 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- PermitMajor alteration
Permit 589400 · COMPLETED
AS PER EZ COMMERCIAL ALTERATIONS - CONTRACTOR LICENSED BY PA (PA 104935)
- PermitElectrical
Permit 573914 · COMPLETED
INSTALL 5 LOW VOLTAGE EXTERIOR CAMERAS PER 2008 NEC (RESTAURANT)
- PermitElectrical
Permit 491662 · COMPLETED
INSTALL FIRE ALARM SYSTEM 7-MANUAL PULL STATIONS, 11-SMOKE DETECTORS, 1-ANSUL CONNECTION & 13-AUDIO/VISUAL APPLIANCES AS PER NEC 2008 & NFPA 72 (RETAIL STORE JIM'S STEAKS)
- ViolationVIOL BC MESSAGE
Case 126399 · Violation 667668 · Code A-000.0/11 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
- InvestigationBC INSP (likely: building-code inspection)
Case 126399 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- InvestigationCI INSP
Case 88206 · PASSED
The cited inspection visit was marked passed.
- InvestigationCI INSP
Case 88206 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 88206 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationCI INSP
Case 88206 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 82023 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)
Case 82023 · CLOSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.
- InvestigationBC INSP (likely: building-code inspection)
Case 49021 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
- License issue event400 SOUTH CORP (JIMS STEAKS): Food Preparing and Serving business license initially issued
License 358392 · Closed
License event. Registration does not prove present operation or storefront occupancy.
- InvestigationBC INSP (likely: building-code inspection)
Case 49021 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
- License issue event400 SOUTH CORP (JIMS STEAKS): Dumpster License - Public ROW L&I license filing initially issued
License 297981 · Active
License event. Registration does not prove present operation or storefront occupancy.
Where this comes from
- Assessment, spec sheet & owner: OPA Property Assessments, Office of Property Assessment
- Sales & deed history: Realty Transfer Tax records, Recorder of Deeds
- Permits, violations & inspections: L&I Property History · Atlas
- Tax delinquency snapshot · June 2022: Real Estate Tax Delinquencies, Dept. of Revenue
- Historical tax ledger & liens · through 2016: Real Estate Tax Balances, Dept. of Revenue
- Current property-tax balance: Verify with Philadelphia Revenue
- Zoning appeals: L&I & Zoning Board appeals
- Imagery: Street photo © Google · Aerial © Esri, Maxar
Methodology & freshness
This report was assembled Jul 25, 2026, 9:20 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)