Commercial property report

473-81 N 5th St

43,560 sqftCMX3built 1980

Property at a glanceStore

410 Green P Exchange Inve & 227 Green Eb Exchange Inv

2026 assessment
$3.5M OPA value, not a listing price
2027 published assessment
$3.5M Future roll, not the current tax bill
Neighborhood area
Northern Liberties · Callowhill Approximate · based on ZIP 19123
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $3,514,900. It is not yet the billed-year tax basis.

$0$2.5M$5.0M$3.5M200820122016202020242027
Property assessmentAssessmentL&I violationAppealPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record37 events · exact dates, newest first
  1. CertificationFire Alarm Certification
  2. CertificationSprinkler Certification
  3. CertificationSprinkler Certification
  4. CertificationFire Alarm Certification
  5. CertificationFire Alarm Certification
  6. CertificationSprinkler Certification
  7. CertificationFire Alarm Certification
  8. CertificationFire Alarm Certification
  9. CertificationFire Alarm Certification
  10. CertificationFire Alarm Certification
  11. PermitSigns (Accessory / Non-Accessory)
  12. PermitRoof Covering Replacement
  13. InspectionL&I investigation
  14. PermitTemporary Tents and Canopies
  15. InspectionL&I investigation
  16. L&I violationTENTS/MEMBRANE STRUCTURES
  17. PermitTemporary Tents and Canopies
  18. PermitElectrical
  19. PermitElectrical
  20. PermitMechanical
  21. PermitSuppression
  22. PermitPlumbing
  23. PermitPlumbing
  24. PermitElectrical
  25. PermitMajor alteration
  26. PermitTemporary Tents and Canopies
  27. PermitDemolition
  28. PermitUse
  29. PermitAdministrative
  30. AppealBuilding standards appeal
  31. PermitElectrical
  32. L&I violationPERM - MUST POST
  33. PermitSuppression
  34. PermitMechanical
  35. PermitAdministrative
  36. PermitPlumbing
  37. PermitElectrical

Verify the public record

$49,202/year estimated property tax

2026 taxable assessment $3,514,900 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $3,514,900. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 771091500
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Store, recorded in the City's commercial category. The public record and owner trail follow.

What it is
Store Store 2 Sty Masonry
Owner
410 Green P Exchange Inve & 227 Green Eb Exchange Inv
$ / sq ft
$81 below the $151 median for 7,668 commercial parcels citywide
Corridor
Spring Garden/2nd-9th city commercial corridor
Interior area
43,560 sqft
Lot size
38,319 sqft
Built
1980
Zoning
CMX3

Recorded owner

Who's behind it

410 Green P Exchange Inve & 227 Green Eb Exchange Inv · corporate / LLC owner

• Tax bills mail to 812 Mount Pleasant Rd, Bryn Mawr PA, 19010 — outside Philadelphia

Block context

400 block of N 5th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 453-71 N 5th St  ·  441-45 N 5th St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 37 dated rows
  1. CertificationFire Alarm Certification

    Certification BC-2026-018835 · Certified

    Expires 2027-06-19

  2. CertificationSprinkler Certification

    Certification BC-2026-018837 · Certified

    Expires 2027-06-19

  3. CertificationSprinkler Certification

    Certification BC-2025-017260 · Certified

    Expires 2026-06-16

  4. CertificationFire Alarm Certification

    Certification BC-2025-017258 · Certified

    Expires 2026-06-16

  5. CertificationFire Alarm Certification

    Certification BC-2024-024477 · Certified

    Expires 2025-07-25

  6. CertificationSprinkler Certification

    Certification BC-2024-024473 · Certified

    Expires 2025-07-25

  7. CertificationFire Alarm Certification

    Certification BC-2024-017421 · Certified

    Expires 2025-05-28

  8. CertificationFire Alarm Certification

    Certification BC-2023-014430 · Certified

    Expires 2024-06-09

  9. CertificationFire Alarm Certification

    Certification BC-2022-014816 · Certified

    Expires 2023-06-27

  10. CertificationFire Alarm Certification

    Certification BC-2022-014774 · Certified

    Expires 2023-03-04

  11. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2021-007207 · Issued

    FOR THE REMOVAL AND REPLACEMENT OF ONE (1) STATICALLY ILLUMINATED WALL SIGN AND ONE (1) NON-ILLUMINATED WALL SIGN. FOR THE ERECTION OF ONE (1) NON-ILLUMINATED WALL SIGN. ALL SIGNS LOCATED BELOW THE BOTTOM OF THE SECOND FLOOR. SIZES AND LOCATIONS AS SHOWN ON APPLICATION/PLAN.

  12. PermitRoof Covering Replacement

    Permit GM-2021-002933 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  13. InvestigationL&I investigation

    Case CF-2021-001771 · PASSED

    The cited inspection visit was marked passed.

  14. PermitTemporary Tents and Canopies

    Permit OP-2020-000434 · Expired

    ASSEMBLY USE TENT - Erecting 20'X40" tent (800 sq. ft.) for Tables & Chairs (OUTDOOR DINING) 12/09/2020 with Existing GFCI Protected Outlets for Temporary Caf?/Streetery - LAWFUL OCCUPANCY SHALL BE AS POSTED - REMOVAL DATE: 05/26/2021 ELECTRICAL PERMIT REQUIRED, UNLESS POWER IS PROVIDED THROUGH EXISTING EXTERIOR GROUND FAULT PROTECTED RECEPTACLES AND POWER CORDS ARE RATED EXTRA HEAVY DUTY WITH U. L. LABEL STATING SUCH RATING. NO COOKING OR HEATING PERMITTED WITH THIS APPROVAL. IF TENT IS NOT READY FOR INSPECTION TO INCLUDE ELECTRICAL COMPONENTS, AN ADDITIONAL FEE OF $200.00 WILL BE APPLIED FOR ANY AFTER HOURS INSPECTION WITH POSSIBLE ISSUANCE OF CODE VIOLATION NOTICES. ELECTRICAL PERMIT NUMBER MUST BE PROVIDED 24-HRS PRIOR TO EVENT.

  15. InvestigationL&I investigation

    Case CF-2021-001771 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. ViolationTENTS/MEMBRANE STRUCTURES

    Case CF-2021-001771 · Violation VI-2021-001196 · Code FC-13-105.6.13 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  17. PermitTemporary Tents and Canopies

    Permit OP-2020-000080 · Completed

    Install 2 tents (1) 400 sq ft (1) 4,000 sq ft

  18. PermitElectrical

    Permit 981035 · COMPLETED

    CLASS 2 FIRE POWER LIMITED FPL FIRE ALARM CABLING, 23 SMOKE DETECTORS, 3 HEAT DETECTORS, 3 MANUAL PULL STATIONS, 9 CEILING STROBE LIGHTS, 6 CEILING COMBO HORN STROBES, 1 FIRE ALARM CONTROL PANEL AND 1 REMOTE ANNUNCIATOR. SYSTEM IS BEING INSTALLED TO MEET THE REQUIREMENTS FOR THE STATE DEPT OF HEALTH FOR A MEDICAL CANIBUS FACILITY AS PER 2017 NEC (CC DIST)

  19. PermitElectrical

    Permit 980940 · COMPLETED

    FURNISH AND INSTALL WIRING FOR TELE/DATA AND TV. INSTALL OWNER SUPPLIED LIGHT FIXTURES AND LIGHTING CONTROL DEVICES. CONNECT OWNER SUPPLIED GENERATOR AND TRANSFER SWITCH. CONNECT HVAC EQUIPMENT. FURNISH AND INSTALL RECEPTACLES. 1-100AMP PANEL, 1-200AMP PANEL AND SUB METER. ALL IN ACCORDANCE WITH DRAWINGS E-00A THRU E-810 AS PER 2017 NEC (CC DIST)

  20. PermitMechanical

    Permit 979906 · COMPLETED

    FOR ALTERATIONS TO AN EXISTING HVAC MECHANICAL SYSTEM TO INCLUDE NEW AIR HANDLERS, CONDENSING UNIT, REGISTERS/DIFFUSERS/GRILLES, AND ASSOCIATED DUCTWORK.

  21. PermitSuppression

    Permit 988224 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  22. PermitPlumbing

    Permit 980974 · COMPLETED

    5 W/C, 3 LAVS, 1 URINAL, 1 DRINKING FOUNTAIN, 2 SINKS, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004

  23. PermitPlumbing

    Permit 980967 · COMPLETED

    1 MOP RECEPTACLE, 1 LAV, INSTALLATION WILL COMPLY WITH PHILADELPHIA PLUMBING CODE 2004

  24. PermitElectrical

    Permit 980243 · COMPLETED

    INSTALL CAT5E CABLING FOR 51-NETWORK CAMERAS WITH LONGEST RUN OF 90FT,CLASS 2 CABLING FOR 15-CARD ACCESS READERS AND 14-ELECTRIC DOOR STRIKES LONGEST RUN OF 75FT,CLASS 2 CABLING FOR 2-KEYPADS,14-MOTION SENSORS,1-GLASSBREAK DETECTOR,5-DOOR POSITION SWITCHES,MAIN CONTROL PANELS AND 1-EXTERIOR SIREN AS PER 2017 NEC (NC DISTRICT)

  25. PermitMajor alteration

    Permit 967925 · COMPLETED

    DEMOLITION OF EXISTING INTERIOR FINISHES AT SELECTED AREAS, FRAME NEW WALLS AS INDICATED ON PLANS. DRYWALL AND PAINT. INSTALL DROP CEILING AND CABINETS AS SHOWN ON PLANS. INSTALL NEW BATHROOM PARTITIONS. NO STRUCTURAL WORK. SEPARATE PERMITS FOR M, E, P REQUIRED.

  26. PermitTemporary Tents and Canopies

    Permit 26263 · Completed

  27. PermitDemolition

    Permit 970731 · COMPLETED

    INTERIOR DEMOLITION. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; UNDERPINNING AND EXCAVATIONS (I.E. DIGGING IN BASEMENT). NOTE: CONTRACTOR IS LISTED AS A "SOLE PROPRIETOR" AND HAS NO EMPLOYEES AND/OR WORKERS COMPENSATION INSURANCE - ALL SUBCONTRACTORS REQUIRE SEPARATE LICENSES AND INSURANCE SEPARATE PERMITS REQUIRED FOR PLUMBING, ELECTRICAL AND MECHANICAL WORK. NO OTHER WORK ALLOWED UNDER THIS PERMIT.

  28. PermitUse

    Permit 918740 · COMPLETED

    USE OF 1ST FLOOR OF AN EXISTING SINGLE STORY BUILDING AS A MEDICAL MARIJUANA DISPENSARY.

  29. PermitAdministrative

    Permit 184266 · COMPLETED

    AMENDING PERMIT #162482 (WHICH WAS AN AMENDED PERMIT FOR #31931 ORIGINALLY); PER RE-SUBMITTED DRAWINGS

  30. AppealBuilding standards appeal

    Appeal 8472 · OPEN · APPROVED

    Related permit 184266 · ON 2/10/09 DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED REFUSAL OF PERMIT FOR APPLICATION #184266

  31. PermitElectrical

    Permit 194919 · COMPLETED

    INCLUSIVE OF FIRE ALARM SYSTEM INSTALLATION IN AREAS WHERE WE ARE WORKING AS PER NFPA72 (CC DISTRICT)

  32. ViolationPERM - MUST POST

    Case 176305 · Violation 1163937 · Code A-302.8/30 · COMPEXCP

  33. PermitSuppression

    Permit 184091 · COMPLETED

    RELOCATE 78 SPRINKLER HEADS;NO CHANGE IN # OF HEADS IN 1ST FLOOR OF CHAPEL & OFFICE

  34. PermitMechanical

    Permit 176305 · COMPLETED

    NEW HVAC AND DUCTWORK

  35. PermitAdministrative

    Permit 162482 · COMPLETED

    AMENDING PERMIT # 31931 & NONCOMBUSTIBLE CONSTRUCTION ONLY PER SUBMITTED SEALED PLANS.

  36. PermitPlumbing

    Permit 175891 · COMPLETED

    (1) LAVATORY, (5) WATER CLOSETS, (3) KITCHEN SINKS

  37. PermitElectrical

    Permit 173782 · COMPLETED

    800AMP SERVICE, DATA/COMMUNICATION, WIRING DEVICES AND LIGHTING AS PER 2005 NEC (CC DISTRICT)

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 11:20 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.