Property report

625-35 E Wister St

553,779 sqftRSA1built 2007

Property at a glanceCommercial

La Salle University

2026 assessment
$11M OPA value, not a listing price
2027 published assessment
$11M Future roll, not the current tax bill
Neighborhood area
Germantown Approximate · based on ZIP 19144
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $10,929,500. It is not yet the billed-year tax basis.

$0$10M$20M$11M200720112015201920232027
Property assessmentAssessmentL&I violationAppealPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record127 events · exact dates, newest first
  1. CertificationSpecial Hazards Certification
  2. CertificationFire Alarm Certification
  3. CertificationFire Alarm Certification
  4. CertificationFire Alarm Certification
  5. CertificationFire Alarm Certification
  6. CertificationFire Alarm Certification
  7. CertificationSprinkler Certification
  8. CertificationFire Alarm Certification
  9. CertificationSprinkler Certification
  10. CertificationSprinkler Certification
  11. CertificationEmergency and Standby Power Systems Certification
  12. CertificationSpecial Hazards Certification
  13. CertificationSprinkler Certification
  14. CertificationFire Alarm Certification
  15. CertificationFire Alarm Certification
  16. CertificationSprinkler Certification
  17. CertificationFacade Report
  18. CertificationFacade Report
  19. CertificationFacade Report
  20. CertificationFacade Report
  21. CertificationEmergency and Standby Power Systems Certification
  22. CertificationSpecial Hazards Certification
  23. CertificationEmergency and Standby Power Systems Certification
  24. CertificationSprinkler Certification
  25. CertificationFire Alarm Certification
  26. CertificationSprinkler Certification
  27. CertificationFire Alarm Certification
  28. CertificationSprinkler Certification
  29. CertificationFire Alarm Certification
  30. CertificationEmergency and Standby Power Systems Certification
  31. CertificationSprinkler Certification
  32. CertificationSprinkler Certification
  33. PermitNew Construction
  34. PermitAddition and/or Alteration
  35. InspectionAIU INSP
  36. CertificationPrivate Bridge Report
  37. InspectionAIU INSP
  38. L&I violationPRIVATE BRIDGES
  39. InspectionAIU INSP
  40. PermitZoning/use
  41. InspectionAIU INSP
  42. InspectionAIU INSP
  43. InspectionAIU INSP
  44. AppealZoning board appeal
  45. PermitRoof Covering Replacement
  46. InspectionAIU INSP
  47. InspectionAIU INSP
  48. InspectionAIU INSP
  49. CertificationFacade Report
  50. CertificationFacade Report
  51. CertificationFacade Report
  52. L&I violationFACADES
  53. L&I violationFACADES
  54. L&I violationFACADES
  55. InspectionAIU INSP
  56. InspectionAIU INSP
  57. InspectionAIU INSP
  58. PermitPlumbing
  59. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  60. PermitSuppression
  61. L&I violationCERTIFICATION
  62. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  63. PermitElectrical
  64. PermitMechanical
  65. PermitMajor alteration
  66. PermitDemolition
  67. PermitSuppression
  68. PermitAlteration
  69. PermitDemolition
  70. PermitZoning/use
  71. PermitAdministrative
  72. PermitPlumbing
  73. PermitElectrical
  74. PermitSuppression
  75. PermitSuppression
  76. PermitSuppression
  77. PermitElectrical
  78. PermitMechanical
  79. PermitPlumbing
  80. PermitPlumbing
  81. PermitNew construction
  82. PermitElectrical
  83. PermitSuppression
  84. PermitZoning
  85. PermitZoning/use
  86. PermitZoning/use
  87. PermitPlumbing
  88. PermitAdministrative
  89. PermitUse
  90. AppealZoning board appeal
  91. PermitElectrical
  92. PermitPlumbing
  93. PermitMajor alteration
  94. PermitZoning
  95. PermitUse
  96. AppealZoning board appeal
  97. PermitSuppression
  98. PermitSuppression
  99. PermitElectrical
  100. PermitPlumbing
  101. PermitSuppression
  102. PermitMechanical
  103. PermitElectrical
  104. PermitMajor alteration
  105. PermitElectrical
  106. PermitMajor alteration
  107. PermitMechanical
  108. PermitElectrical
  109. PermitPlumbing
  110. PermitElectrical
  111. PermitSuppression
  112. PermitMajor alteration
  113. PermitAddition
  114. PermitZoning/use
  115. AppealZoning board appeal
  116. PermitSuppression
  117. PermitPlumbing
  118. PermitSuppression
  119. PermitSuppression
  120. PermitSuppression
  121. PermitPlumbing
  122. PermitPlumbing
  123. PermitPlumbing
  124. PermitPlumbing
  125. PermitPlumbing
  126. PermitPlumbing
  127. PermitPlumbing

Verify the public record

$29,116/year estimated property tax

2026 taxable assessment $2,080,015 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $10,929,500. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 776008010
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $2,080,015 of $10,929,500 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Not a house

Commercial. A $0 assessment-based estimate does not prove the live Tax Center account has no prior-period balance or other charges.

What it is
Commercial Health Fac Hosp Mas+Oth
Owner
La Salle University Public / institutional
$ / sq ft
$20 below the $151 median for 7,668 commercial parcels citywide
Interior area
553,779 sqft
Lot size
1,063,743 sqft
Built
2007
Zoning
RSA1

Recorded owner

Who's behind it

La Salle University · corporate / LLC owner

• Owns 16 properties across Philadelphia under this name, assessed at $19M combined

Block context

600 block of E Wister St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 625-35 E Wister St  ·  625-35 E Wister St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 10, 2026.

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 127 dated rows
  1. CertificationSpecial Hazards Certification

    Certification BC-2026-016209 · Certified

    Expires 2027-03-09

  2. CertificationFire Alarm Certification

    Certification BC-2026-002718 · Deficient

  3. CertificationFire Alarm Certification

    Certification BC-2026-002722 · Deficient

  4. CertificationFire Alarm Certification

    Certification BC-2026-002725 · Deficient

  5. CertificationFire Alarm Certification

    Certification BC-2026-002719 · Deficient

  6. CertificationFire Alarm Certification

    Certification BC-2026-002720 · Deficient

  7. CertificationSprinkler Certification

    Certification BC-2025-023978 · Deficient

  8. CertificationFire Alarm Certification

    Certification BC-2026-000205 · Deficient

  9. CertificationSprinkler Certification

    Certification BC-2025-023890 · Deficient

  10. CertificationSprinkler Certification

    Certification BC-2025-021802 · Deficient

  11. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-011988 · Certified

    Expires 2026-04-23

  12. CertificationSpecial Hazards Certification

    Certification BC-2025-016523 · Certified

    Expires 2026-03-25

  13. CertificationSprinkler Certification

    Certification BC-2025-005289 · Certified

    Expires 2026-03-03

  14. CertificationFire Alarm Certification

    Certification BC-2025-017136 · Deficient

  15. CertificationFire Alarm Certification

    Certification BC-2024-028005 · Certified

    Expires 2025-08-12

  16. CertificationSprinkler Certification

    Certification BC-2024-024657 · Deficient

  17. CertificationFacade Report

    Certification BC-2024-019734 · Safe with Repair

    Expires 2029-07-03

  18. CertificationFacade Report

    Certification BC-2024-019501 · Safe with Repair

    Expires 2029-06-28

  19. CertificationFacade Report

    Certification BC-2024-019732 · Safe with Repair

    Expires 2029-06-28

  20. CertificationFacade Report

    Certification BC-2024-019731 · Safe with Repair

    Expires 2029-06-27

  21. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-012928 · Certified

    Expires 2025-04-02

  22. CertificationSpecial Hazards Certification

    Certification BC-2024-006171 · Certified

    Expires 2025-02-27

  23. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017760 · Certified

    Expires 2025-02-14

  24. CertificationSprinkler Certification

    Certification BC-2024-009595 · Deficient

  25. CertificationFire Alarm Certification

    Certification BC-2024-005080 · Deficient

  26. CertificationSprinkler Certification

    Certification BC-2024-007918 · Certified

    Expires 2024-07-27

  27. CertificationFire Alarm Certification

    Certification BC-2023-021506 · Certified

    Expires 2024-07-26

  28. CertificationSprinkler Certification

    Certification BC-2024-007923 · Certified

    Expires 2024-07-24

  29. CertificationFire Alarm Certification

    Certification BC-2023-021493 · Deficient

  30. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017692 · Certified

    Expires 2024-03-31

  31. CertificationSprinkler Certification

    Certification BC-2023-003863 · Deficient

  32. CertificationSprinkler Certification

    Certification BC-2022-017273 · Certified

    Expires 2023-06-09

  33. PermitNew Construction

    Permit 1052062 · Completed

    REPLACE EXISTING LIGHT POLE INSTALL 100AMP SERVICE W/ 60 AMP DISCONNECT. EXTEND 30AMP SERVICE TO RADIO EQUIPMENT PER 2017 NEC (NORTH DIST)

  34. PermitAddition and/or Alteration

    Permit 1010656 · Completed

    FOR THE REPLACEMENT OF A LIGHT POLE THAT WILL INCLUDE ONE (1) ANTENNA MOUNTED ON TOP WITH ONE (1) EQUIPMENT CABINET MOUNTED TO THE SIDE OF THE POLE AT 10' ABOVE GRADE, SIZE AND LOCATION AS SHOWN ON PLAN/APPLICATION.SEPARATE PERMITS REQUIRED FOR ELECTRICAL WORK; SEE AP#950045 FOR ZONING APPROVAL.

  35. InvestigationAIU INSP

    Case 703008 · PASSED

    The cited inspection visit was marked passed.

  36. CertificationPrivate Bridge Report

    Certification BC-2022-011955 · Safe with Repair

    Expires 2024-12-04

  37. InvestigationAIU INSP

    Case 703008 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  38. ViolationPRIVATE BRIDGES

    Case 703008 · Violation 5249003 · Code PM15-316.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  39. InvestigationAIU INSP

    Case 703008 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  40. PermitZoning/use

    Permit 950045 · COMPLETED

    FOR THE REMOVAL OF AN EXISTING LIGHT POLE AND REPLACED WITH A NEW LIGHT POLE THAT WILL INCLUDE ONE (1) ANTENNA MOUNTED ON TOP WITH ONE (1) EQUIPMENT CABINET MOUNTED TO THE SIDE OF THE POLE AT 10' ABOVE GRADE, SIZE AND LOCATION AS SHOWN ON PLAN/APPLICATION. FOR USE AS WIRELESS SERVICE FACILITIES AS PART OF AN EXISTING EDUCATIONAL INSTITUTION ON THE SAME LOT WITH ALL OTHER USES AS PREVIOUSLY APPROVED.

  41. InvestigationAIU INSP

    Case 678284 · PASSED

    The cited inspection visit was marked passed.

  42. InvestigationAIU INSP

    Case 678281 · PASSED

    The cited inspection visit was marked passed.

  43. InvestigationAIU INSP

    Case 678287 · PASSED

    The cited inspection visit was marked passed.

  44. AppealZoning board appeal

    Appeal 37235 · OPEN · Granted

    Related permit 950045 · SPECIAL EXCEPTION FOR THE REMOVAL OF AN EXISTING LIGHT POLE AND REPLACED WITH A NEW LIGHT POLE THAT WILL INCLUDE ONE (1) ANTENNA MOUNTED ON TOP WITH ONE (1) EQUIPMENT CABINET MOUNTED TO THE SIDE OF THE POLE AT 10' ABOVE GRADE, SIZE AND LOCA

  45. PermitRoof Covering Replacement

    Permit 980809 · Expired

    FURNISH AND INSTALL NEW ROOFING SYSTEM.

  46. InvestigationAIU INSP

    Case 678281 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  47. InvestigationAIU INSP

    Case 678287 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  48. InvestigationAIU INSP

    Case 678284 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  49. CertificationFacade Report

    Certification BC-2022-003129 · Safe with Repair

    Expires 2024-05-15

  50. CertificationFacade Report

    Certification BC-2022-003068 · Safe with Repair

    Expires 2024-05-14

  51. CertificationFacade Report

    Certification BC-2022-003130 · Safe with Repair

    Expires 2024-05-14

  52. ViolationFACADES

    Case 678281 · Violation 5051599 · Code PM15-315.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  53. ViolationFACADES

    Case 678284 · Violation 5051601 · Code PM15-315.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  54. ViolationFACADES

    Case 678287 · Violation 5051602 · Code PM15-315.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  55. InvestigationAIU INSP

    Case 678281 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  56. InvestigationAIU INSP

    Case 678284 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  57. InvestigationAIU INSP

    Case 678287 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  58. PermitPlumbing

    Permit 856989 · EXPIRED

    ALTERATIONS: INTERIOR PLUMBING; EDUCATIONAL FACILITY, LA SALLE UNIVERSITY BUILDING ; 1ST FLOOR SAXBY COFFEE; DRAINS MUST BE A MINIMUM OF 1" TRAPPED INDIRECT WASTE PIPING IN ACCORDANCE WITH CHAPTER 12 & TABLE P-904.7 PPC; FOOD PREP SINK IS REQUIRED TO HAVE A 2" TRAPPED INDIRECT WASTE LINE PER TABLE P?904.7; ICE , COFFEE & ESPRESSO MACHINES REQUIRE THE WATER SUPPLY BE PROTECTED BY A LOW?HAZARD BACKFLOW PREVENTION ISOLATION DEVICE FROM TABLE 608.1 OF THE 2009 INTERNATIONAL PLUMBING CODE, CONFORMING TO ASSE 1022; 1 WATER HEATER,3 FLOOR SINK,1 FLOOR DRAINS,1 GREASE TRAP. MAKING FINAL CONNECTION TO 1 WATER FILTER,2 HAND SINKS, 1 PREP SINK, 1 ICE MAKER,1 COFFEE MAKER, 1 ESPRESSO MACHINE - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  59. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 626840 · PASSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.

  60. PermitSuppression

    Permit 865179 · COMPLETED

    RELOCATE 6 EXISTING SPRINKLER HEADS (COMMERCIAL)

  61. ViolationCERTIFICATION

    Case 626840 · Violation 4625052 · Code FC-13-915 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  62. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 626840 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  63. PermitElectrical

    Permit 852265 · COMPLETED

    LIGHTING,RECEPTACLES,DATA,SPEAKERS AND CAMERAS PER 2008 NEC(RESTAURANT)

  64. PermitMechanical

    Permit 849726 · EXPIRED

    HVAC, TO INCLUDE, INSTALLATION OF TWO DUCTLESS SPLIT-SYSTEM, AS PER PLANS.

  65. PermitMajor alteration

    Permit 851406 · COMPLETED

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. INTERIOR ALTERATIONS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK.

  66. PermitDemolition

    Permit 848057 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. REMOVE TWO (2) DOORS AND TWO (2) INTERIOR NON-LOAD BEARING WALLS. NO OTHER WORK ON THIS PERMIT. PLEASE CALL THE INSPECTOR AT LEAST 24 HOURS PRIOR TO THE START OF WORK.

  67. PermitSuppression

    Permit 816919 · COMPLETED

    FOR THE EXTENSION OF AN EXISTING AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH NFPA 13 WITHIN SUITE 216 ON THE 2ND FLR OF AN EXISTING DETACHED MEDICAL OFFICE BUILDING, USING EXISTING FIRE SERVICE LINES AND BACKFLOW PREVENTION DEVICE, AS PER PLANS; NO OTHER WORK ON THIS PERMIT.

  68. PermitAlteration

    Permit 795766 · COMPLETED

    ROOF REPLACEMENT (BUILT UP ROOF SYSTEM WITH GRANULAR).

  69. PermitDemolition

    Permit 663316 · COMPLETED

    FOR REOLUTION OF DEPT. OF L+I CASE# 502602 (ISSUED AGAINST 05308 CHEW ST) FOR THE DEMOLITION OF EXISTING SEMI-DETACHED TWO (2) STORY ABOVE GRADE PLANE, W. BASEMENT, RESIDENTIAL BUILDING. ALL PERMITTED DEMOLITION ACTIVITY TO BE IN ACCORDANCE WITH APPROVED SITE SAFETY DEMOLITION PLAN & SUCH PLAN TO BE MAINTAINED ON SITE AT ALL TIMES.2/9/16 OWNER WAS ISSUED PERMIT #663316

  70. PermitZoning/use

    Permit 663309 · COMPLETED

    FOR COMPLETE DEMOLITION OF EXISTING SEMI-DETACHED BUILDING ON THE SAME LOT WITH MULTIPLE BUILDING AS PREVIOUSLY APPROVED; SIZE & LOCATION AS SHOWN IN APPLICATION. USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY OF ANY DEVELOPMENT WITH ALL OTHER USES AS PREVIOUSLY APPROVED THROUGHOUT THE EXISTING 'UNITY OF USE' AGREEMENT.

  71. PermitAdministrative

    Permit 664255 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR LASALLE UNIVERSITY SCHOOL OF BUSINESS. ONLY ELEVATOR CAR #1 TO BE USED UNTIL CAR # 2 IS STATE CERTIFIED, AT WHICH TIME CERTIFICATE OF OCCUPANCE WILL BE ISSUED

  72. PermitPlumbing

    Permit 659961 · EXPIRED

    SEAL 5" SEWER LATERAL, CURB TRAP AND FRESH AIR INLET PA ONE CALL #2015-3510995

  73. PermitElectrical

    Permit 644725 · COMPLETED

    INSTALLING VOICE AND DATA COMMUNICATIONS AND FIBER OPTIC BACKBONE PER 2008 NEC (EDUCATIONAL FACILITY)NORTH DISTRICT

  74. PermitSuppression

    Permit 625829 · COMPLETED

    INSTALL NEW SPRINKLER SYSTEM EXTENDED FROM EXISTING 2"FEED IN CORRIDOR. SYSTEM INSTALLED IN ACCORDANCE WITH NFPA 13

  75. PermitSuppression

    Permit 601413 · COMPLETED

    INSTALL SPRINKLER SYSTEM NFPA 13, INCLUDING PUMP, STANDPIPES.FEED MAIN 6" CERTIFYING CODE DESIGNER: JOHN FEE, PE

  76. PermitSuppression

    Permit 627347 · COMPLETED

    INSTALLATION OF GROOVE REDUCER ON EXISTING 3" MAIN, EXTEND NEW 2" MAIN AND BRANCH LINES TO PROVIDE SPRINKLER COVERAGE (PENDENTS) THROUGHOUT SUITE 210 IN ACCORDANCE WITH NFPA 13 PER PLANS. SEPARATE PERMITS REQUIRED FOR ANY INTERIOR FITOUT, ELECTRICAL OR PLUMBING WORK.

  77. PermitElectrical

    Permit 584480 · COMPLETED

    MAIN SERVICE,SITE LIGHTS,POWER AND LIGHTING IN BLDG AND ELEVATORS AS PER 2008 NEC (UNIVERSITY) INSTALL FIRE ALARM SYSTEM AS PER NFPAF72

  78. PermitMechanical

    Permit 563892 · COMPLETED

    INSTALL DUCTWORK, REGISTERS/DIFFUSERS, MECHANICAL UNITS, PIPING AND INCIDENTALS THROUGHOUT BUILDING IN ACCORDANCE WITH APPROVED PLANS (ENGINEER SIGNED AND SEALED) AND PLAN REVIEW FORM.

  79. PermitPlumbing

    Permit 565112 · COMPLETED

    PLUMBING FOR NEW EDUCATIONAL FACILITY

  80. PermitPlumbing

    Permit 557215 · COMPLETED

    6-LATERAL CONNECTIONS, 4-RAIN GARDEN BASINS, 1-SUB-SURFACE INFILTRATION BASIN, 1 ROOF DRAIN, 2-INLETS, 7-AREA DRAINS, 1-4" DOMESTIC WATER SERVICE TO 5'0" FROM PROPOSED BLDG (UNIVERSITY) PA 20142271843 & 20142271856 SELF-CERIFICATION'S ARE NO LONGER PERMITTED - ALL EXCAVATIONS & PLUMBING TRENCHES IN EXCESS OF 5' IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION

  81. PermitNew construction

    Permit 543018 · COMPLETED

    NEW CONSTRUCTION OF 6 STORY STRUCTURE, ASSOCIATED SITE AND CIVIL WORK( AS APPROVED BY PWD STORMWATER MGMNT). BUILDING FULLY SPRINKLERED. ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS/S.PIPES . AMEND FOR SP INSPECTIONS AGENCY.

  82. PermitElectrical

    Permit 544714 · COMPLETED

    ADDING 7 HORN AND STROBES TO EXISTING SPACE PER 2008 NEC & NFPA 72 (UNIVERSITY)

  83. PermitSuppression

    Permit 534592 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM TIEING INTO AN EXISTING SYSTEM ON THE SECOND FLOOR (CLARKE CORA SUITES) OF AN EXISTING BUILDING IN ACCORDANCE WITH NFPA 13 AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  84. PermitZoning

    Permit 535289 · COMPLETED

    FOR THE CREATION OF A UNITY OF USE TO CREATE ONE (1) LOT FOR ZONING PURPOSES (TO BE KNOWN AS 625-635 E WISTER STREET) WITH RESPECTIVE COVENANTS, AGREEMENTS AND EASEMENTS TO BE RECORDED BY DEED OR OTHER AGREEMENT APPROVED BY THE CITY'S LAW DEPARTMENT TO BIND CURRENT AND FUTURE OWNERS OF THE CONTIGUOUS THREE (3) PARCELS (625-35 E WISTER ST, UNIT 1, 723 E WISTER ST & 738 E PENN ST) TO PRESERVE THE UNITY OF USE AND THE LEGALITY OF THE ENTIRE PROJECT THAT STEMS FROM SINGLE ZONING LOT TREATMENT. PRIOR TO ISSUANCE OF CERTIFICATION OF OCCUPANCY, PROOF RECORDATION OF EASEMENTS, AGREEMENTS AND RESTRICTIVE COVENANTS MUST BE SUPPLIED. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION.

  85. PermitZoning/use

    Permit 535305 · COMPLETED

    FOR THE ERECTION OF A DETACHED STRUCTURE (BUILDING "U"). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. BUILDING "U" FOR USE AS AN EDUCATIONAL FACILITY WITH A CAFETERIA (SIT-DOWN RESTAURANT); ON THE SAME LOT AS EXISTING STRUCTURES (NO CHANGE IN PREVIOUSLY APPROVED USES, HEIGHT, OR AREA). EXISTING BUILDINGS "A" - "T" FOR CONTINUED USE AS EDUCATIONAL FACILITY, HOSPITAL AND OTHER APPROVED USES. A TOTAL OF FIVE HUNDRED EIGHTY-EIGHT (588) ACCESSORY PARKING SPACES ON THE LOT, (INCLUDING TWENTY-FIVE (25) ACCESSIBLE SPACES (EIGHT (8) VAN ACCESSIBLE SPACES)). NO SIGNS ON THIS APPLICATION; PREVIOUSLY APPROVED SIGNAGE TO REMAIN. SEE A/P NO 519654

  86. PermitZoning/use

    Permit 428721 · COMPLETED

    REMOVE 3 DUAL POLE ANTENNAS & REPLACE WITH 3 QUAD POLE ANTENNAS. REMOVE 3 RADIO HEADS AND REPLACE WITH 3 NRRH V2 RADIO HEADS.

  87. PermitPlumbing

    Permit 412694 · COMPLETED

    RELOCATING TWO POWDER ROOMS TO ACCOMDATE ADA CONVERTING TWO HAND WASH BASINS TO TWO DROP IN SINKS

  88. PermitAdministrative

    Permit 410559 · COMPLETED

    CERTIFICATE OF OCCUPANCY

  89. PermitUse

    Permit 399289 · COMPLETED

    PROPOSED DAYCARE/PRESCHOOL FOR MAXIMUM SIXTY (60) CHILDREN (NOT AFFILIATED) FOR PERIODS OF LESS THAN 24 CONSECUTIVE HOURS WITH ACCESSORY PREPARING AND SERVING OF FOOD IN SPACE NUMBERS 201 TO 224 ON THE 2ND FLOOR WITH OUTDOOR PLAY AREA WITH EXISTING SCHOOL FOR THE DEAF ON THE SECOND FLOOR IN SPACE 215,218 & 220 OF THE MEDICAL OFFICE BUILDING ON THE SAME LOT WITH EXISTING UNIVERSITY (NURSING SCHOOL), A HOSPITAL COMPLEX AND PRIVATE MEDICAL OFFICES CREATES A CONDITION OF MULTIPLE MAIN USES ON A LOT WITH EXISTING ACCESSORY PARKING AS PREVIOUSLY APPROVED (SIZE AND LOCATION AS SHOWN IN THE APPLICATION).

  90. AppealZoning board appeal

    Appeal 17792 · CLOSED · Granted

    Related permit 399289 · PERMIT FOR PROPOSED DAYCARE/PRESCHOOL FOR MAXIMUM SIXTY (60) CHILDREN (NOT AFFILIATED) FOR PERIODS OF LESS THAN 24 CONSECUTIVE HOURS WITH ACCESSORY PREPARING AND SERVING OF FOOD IN SPACE NUMBERS 201 TO 224 ON THE 2ND FLOOR WITH OUTDOOR PLA

  91. PermitElectrical

    Permit 401780 · COMPLETED

    USE EXISTING CIRCUITS, INSTALL RECEPTACLES & LIGHTS AS PER 2008 NEC(NORTH DIST), NO FIRE ALARM-INSTALLATION AT THIS TIME. (MEDICAL OFFICE/UNIV)

  92. PermitPlumbing

    Permit 402340 · COMPLETED

    REPLACE FIXTURES IN 2 POWDER ROOMS AND EXCHANGING HAND BASINS FOR KITCHEN TYPE SINK(COMMERCIAL)

  93. PermitMajor alteration

    Permit 375140 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLAN.

  94. PermitZoning

    Permit 324919 · COMPLETED

    ADDIDING A SCHOOOL FOR THE DEAF ON THE 3ND FLOOR OF THE MOB AS PART OF THE EXISTING MEDICAL OFFICE. NO CHANGE IN HEIGHT OR AREA EXCEPT FOR A PROPOSED 8' FENCE AS SHOWN ON PLANS

  95. PermitUse

    Permit 399044 · COMPLETED

    ADDIDING A SCHOOOL FOR THE DEAF ON THE 3ND FLOOR OF THE MOB AS PART OF THE EXISTING MEDICAL OFFICE. NO CHANGE IN HEIGHT OR AREA EXCEPT FOR A PROPOSED 8' FENCE AS SHOWN ON PLANS

  96. AppealZoning board appeal

    Appeal 14775 · CLOSED · Granted

    Related permit 324919 · PERMIT FOR THE ERECTION OF AN 8 FT HIGH FENCE, FOR A PROPOSED SCHOOL FOR THE DEAF ON THE SECOND FLOOR,ON THE SAME LOT AS EXISTING UNIVERSITY(NURSING SCHOOL), A HOSPITAL COMPLEX AND PRIVATE MEDICAL OFFICES WITH 652 PARKING SPACES, 25 ACCESS

  97. PermitSuppression

    Permit 383777 · COMPLETED

    INSTALL PARTIAL SPRINKLER SYSTEM ON 2ND FLOOR IN ACCORDANCE WITH NFPA 13 AS PER PLANS.

  98. PermitSuppression

    Permit 307315 · COMPLETED

    INSTALLATION OF KIDDE DOUBLE KITCHEN HOOD FOR EXISTING KITCHEN.

  99. PermitElectrical

    Permit 341331 · COMPLETED

    FIRE ALARM UPGRADE ADDING TAMPER AND FLOW SWITCHES FOR SPRINKLER RENOVATION SMOKE AND HEAT DETECTORS FOR ELEVATORS FOR MACHINE ROOM AND SHAFT AS PER 2008 NEC,NFPA-72

  100. PermitPlumbing

    Permit 304182 · COMPLETED

    INSTALLATION OF FOUR "TEACHING" KITCHEN GROUPS. "NOT FOR CONSUMPTION"

  101. PermitSuppression

    Permit 301391 · COMPLETED

    INSTALL (32) SPRINKLERS ON THE 3RD FLOOR OF LASALLE BLDG. CONNECT TO EXTG SYSTEM.

  102. PermitMechanical

    Permit 301303 · COMPLETED

    INSTALL DUCTWORK TO ACCOMODATE KITCHEN HOOD EXHAUST / MAKE-UP AIR SYSTEMS. SEPARATER PERMITS REQUIRED FOR INSTALLATION OF KITCHEN HOODS AND FIRE SUPPRESSION SYSTEMS.

  103. PermitElectrical

    Permit 302036 · COMPLETED

    RELOCATE EXUSTING HOSPITAL KITCHEN POWER FOR NEW LAYOUT,INSTALL 37 RECETACLE FOR EQUIPMENT,NO ANTCIPATED CHANGE IN LOAD PER 2008 NEC

  104. PermitMajor alteration

    Permit 299113 · COMPLETED

    CONVERT HOSPITAL KITCHEN INTO 4 SMALL TEACHING KITCHENS FOR NURSING STUDENTS. NO FOOD WILL BE SOLD OR GIVEN AWAY.

  105. PermitElectrical

    Permit 259411 · COMPLETED

    (PA.PHL 5541)6 LINES OF 1 5/8" COMMSCOPE COAX FROM BACK OF ANTENNAS TO TELCO CABINET. ALL LINE RUNS ARE 175', 1 GPS ANTENNA RUN WITH 1/2" COAX, 30" AS PER 2005 NEC (NORTH DISTRICT)

  106. PermitMajor alteration

    Permit 229164 · COMPLETED

    ERECT (6) ANTENNAS

  107. PermitMechanical

    Permit 182292 · COMPLETED

    INSTALL HVAC SYSTEM PER PLANS

  108. PermitElectrical

    Permit 189478 · COMPLETED

    INSTALL 1 PULL STATION, 5 SMOKE DETECTORS, 3 HORN STROBES AND ALL CABLE FPLP AS PER NFPA72 (NORTH DISTRICT)

  109. PermitPlumbing

    Permit 173998 · COMPLETED

    RAISE EXISTING ROOF DRAINAGE PIPING TO ACCOMODATE NEW 2ND STORY ON TOP OF EXISTING LOBBY. (7 ROOF DR)

  110. PermitElectrical

    Permit 169672 · COMPLETED

    INSTALL 67 NEW LIGH FIXTURES, 15 DUPLEX RECEPTS, 2 GFI RECEPTS AS PER 2005 NEC (NORTH DISTRICT)

  111. PermitSuppression

    Permit 164012 · COMPLETED

    INSTALL (23) AUTO SPRINKLERS

  112. PermitMajor alteration

    Permit 153885 · COMPLETED

    RENOVATIONS TO CREATE A LOBBY AND LANDING AREA FOR NEW BRIDGE ACROSS WISTER STREET

  113. PermitAddition

    Permit 164995 · COMPLETED

    RENOVATIONS TO CREATE A LOBBY AND LANDING AREA FOR NEW BRIDGE ACROSS WISTER STREET

  114. PermitZoning/use

    Permit 120996 · COMPLETED

    USE SAME AS ABOVE; PROPOSES TO ADD TO EXISTING MAIN USES: COLLEGE, UNIVERSITY & CUSTOMER ACCESSORY USES SUCH AS OFFICES LABS & CLASSROOMS;CREATION OF A 2ND STORY ADDITION TO ONE BLDG (KNOW AS WISTER TOWER) OF UNIT #1 PART OF "WEST CAMPUS CONDOMINIUM" (40' 5" X 52') & WILL EXPAND EXISTING PUBLIC SPACE; MAX HT OF PROPOSED ADDITION IS 43' 1"; NO SIGNS ON THIS APPLICATION;NEW CURTAIN SCREEN WALL 46 LONG FROM 87 FROM GRAD TO TOP OF WALL

  115. AppealZoning board appeal

    Appeal 5497 · CLOSED · Granted with conditions

    Related permit 120996 · PERMIT/ CERTIFICATE FOR THE ERECTION OF A SECOND STORY ADDITION (MAXIMUM HEIGHT 43'-1") TO AN EXISTING STRUCTURE TO INCLUDE THE CREATION OF A PORCH/ TERRACE (875 SQ FT) WITH 42" HIGH PROTECTIVE RAILING FOR STUDENT AND FACULTY ACTIVITIES FOR

  116. PermitSuppression

    Permit 150045 · COMPLETED

    INSTALL AN AUTOMATIC SPRINKLER SYSTEM.

  117. PermitPlumbing

    Permit 153858 · COMPLETED

    INCREASE WATER SERVICE FROM 5/8" TO 2", METER #0519859

  118. PermitSuppression

    Permit 148137 · COMPLETED

    INSTALL (85) AUTO SPRINKLERS ON THE 2ND FLR. PARTIAL (GERMANTOWN HEALTH SERVICES)

  119. PermitSuppression

    Permit 120373 · COMPLETED

    INSTALL (115) AUTO SPRINKLERS ON THE 5TH FLR. OF THE SAINT BENILDE TOWER

  120. PermitSuppression

    Permit 113139 · COMPLETED

    INSTALL (120) AUTO SPRINKLERS ON THE 3RD FLR. OF THE SAINT BENILDE TOWER

  121. PermitPlumbing

    Permit 118508 · COMPLETED

    RE-HAB OF EXISTING BATHROOM, RE-HAB OF POWDER ROOM AND RELOCATE K/S

  122. PermitPlumbing

    Permit 118511 · COMPLETED

    RE-HAB BATHROOM, RE-HAB POWDER ROOM, INSTALL WATER FOUNTAIN & BREAK ROOM SINK.

  123. PermitPlumbing

    Permit 118506 · COMPLETED

    INSTALL 6 SINKS AND REPLACEMENT OF FIXTURES IN POWDER ROOM

  124. PermitPlumbing

    Permit 115370 · COMPLETED

    REHAB BATHROOMS AND RELOCATING A KITCHEN SINK IN A BREAK ROOM

  125. PermitPlumbing

    Permit 115371 · COMPLETED

    REHAB BATHROOM ALONG WITH STACK REPLACEMENT

  126. PermitPlumbing

    Permit 115372 · COMPLETED

    REHAB OF BATHROOMS AND REPLACING STACK

  127. PermitPlumbing

    Permit 115373 · COMPLETED

    REHAB EXISTING GANG BATHROOM AND REPLACEMENT OF STACK

Where this comes from

Methodology & freshness

This report was assembled Jul 18, 2026, 2:20 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)