Property report

7400 Lansdowne Ave

Property at a glanceCommercial

Individual owner on record

2026 assessment
$2.2M OPA value, not a listing price
2027 published assessment
$2.2M Future roll, not the current tax bill
Neighborhood area
Overbrook · Overbrook Farms Approximate · based on ZIP 19151
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $2,169,500. It is not yet the billed-year tax basis.

$0$25M$50M$2.2M2006201020142018202220262027
Property assessmentAssessmentTeardownL&I violationAppealPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record86 events · exact dates, newest first
  1. PermitSitework with Onsite Utility Services
  2. PermitNew Construction
  3. PermitNew Construction
  4. PermitMinor Demolition
  5. PermitGeneral Earth Disturbance ONLY
  6. PermitAddition and/or Alteration
  7. PermitSign
  8. PermitSigns (Accessory / Non-Accessory)
  9. TeardownDemolished
  10. PermitAddition and/or Alteration
  11. PermitFence
  12. PermitMinor Demolition
  13. PermitAddition and/or Alterations
  14. PermitAlterations
  15. PermitSign
  16. PermitSigns (Accessory / Non-Accessory)
  17. PermitGeneral Earth Disturbance ONLY
  18. TeardownDemolished
  19. PermitNew construction, addition, GFA change
  20. PermitTemporary Tents and Canopies
  21. PermitFences Only
  22. PermitNew construction, addition, GFA change
  23. PermitNew Construction
  24. PermitSitework with Onsite Utility Services
  25. PermitAddition and/or Alteration
  26. PermitRough-In
  27. PermitNew construction, addition, GFA change
  28. PermitSite Clearing or Earth Disturbance ONLY
  29. PermitNew Construction
  30. PermitTank Install/Removal
  31. PermitTank Install/Removal
  32. PermitNew Construction or Additions
  33. PermitTemporary Tents and Canopies
  34. PermitSitework with Onsite Utility Services
  35. PermitTemporary Tents and Canopies
  36. PermitNew construction, addition, GFA change
  37. PermitTemporary Tents and Canopies
  38. PermitNew construction, addition, GFA change
  39. AppealZBA Permit Denial - Variance
  40. PermitGeneral Earth Disturbance ONLY
  41. PermitNew construction, addition, GFA change
  42. LicenseCOBBS KARAKUNG GOLD MGT (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license marked closed
  43. PermitZoning/use
  44. PermitPlumbing
  45. PermitElectrical
  46. PermitMajor alteration
  47. PermitElectrical
  48. InspectionCSUFINAL
  49. InspectionCSUTESTPIT
  50. InspectionCSUSTUBAR
  51. InspectionCSUCURBINT
  52. InspectionCSUINITIAL
  53. L&I violationID STRUCTURE
  54. L&I violationEXTERIOR STRUCT UNSAFE COND 4
  55. L&I violationEXTERIOR STRUCT UNSAFE COND 8
  56. L&I violationID STRUCTURE
  57. L&I violationEXTERIOR STRUCT UNSAFE COND 8
  58. L&I violationEXTERIOR STRUCT STRUCTURAL MEM
  59. InspectionCSUINITIAL
  60. InspectionCSUFINAL
  61. InspectionCSUINITIAL
  62. InspectionCSUINITIAL
  63. PermitAlteration
  64. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  65. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  66. L&I violationINT COMBUSTIBLE WASTE ACCUMUL
  67. L&I violationEXT-TREES PRUNE/REMOVE
  68. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  69. InspectionCI INSP
  70. PermitElectrical
  71. InspectionCI INSP
  72. L&I violationCOMBUS FIBR-REMOV GRASS/WEEDS
  73. InspectionCI INSP
  74. L&I violationVIOL C&I MESSAGE
  75. InspectionCI INSP
  76. LicenseLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Dumpster License - Private Property L&I license filing marked inactive
  77. PermitMajor alteration
  78. PermitDemolition
  79. PermitZoning/use
  80. LicenseCOBBS KARAKUNG GOLD MGT (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license initially issued
  81. LicenseLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license marked inactive
  82. InspectionBC INSP (likely: building-code inspection)
  83. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  84. InspectionBC INSP (likely: building-code inspection)
  85. LicenseLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license initially issued
  86. LicenseLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Dumpster License - Private Property L&I license filing initially issued

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $2,169,500. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 885712760
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

What it is
Commercial Amuse City Park
Owner
Individual owner on record Individual name redacted
Lot size
4,339,012 sqft

Block context

7400 block of Lansdowne Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
COBBS KARAKUNG GOLD MGT (COBBS CREEK GOLF CLUB)Closed

Food Preparing and Serving · Initial issue date Apr 10, 2008 · Terminal license date Apr 30, 2021

LIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB)Inactive

Food Preparing and Serving · Initial issue date Jul 26, 2006 · Terminal license date Jan 8, 2008

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 85 dated rows
  1. PermitSitework with Onsite Utility Services

    Permit SP-2026-000725 · Issued

    SITEWORK ASSOCIATED WITH UTILITY INSTALLATION FOR NEW MAINTENANCE BUILDINGS (SEE PERMITS CP-2024-004894 & CP-2024-005400) AS PER APPROVED PLANS. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR PLUMBING WORK**

  2. PermitNew Construction

    Permit CP-2024-004894 · Issued

    NEW CONSTRUCTION OF A ONE-STORY DETACHED STRUCTURE (BUILDING 'A') FOR USE AS A MAINTENANCE AND STORAGE FACILITY SERVING AN EXISTING ACTIVE RECREATIONAL FACILITY (GOLF COURSE) AS PER APPROVED PLANS. BUILDING TO BE SPRINKLERED. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  3. PermitNew Construction

    Permit CP-2024-005400 · Issued

    NEW CONSTRUCTION OF A ONE-STORY DETACHED STRUCTURE (BUILDING 'B') FOR USE AS A ADMINISTRATIVE OFFICES SERVING AN EXISTING ACTIVE RECREATIONAL FACILITY (GOLF COURSE) AS PER APPROVED PLANS. BUILDING NOT REQUIRED TO BE SPRINKLERED. AMENDED PERMIT APPROVAL REQUIRED TO SUBMIT TRUSS DRAWINGS PRIOR TO INSTALLATION. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP WORK**

  4. PermitMinor Demolition

    Permit DP-2026-000540 · Completed

    FOR THE COMPLETE DEMOLITION OFEXISTING MASONRY AND WOOD ONE-STORY STRUCTURE BY MECHANICAL METHODS. ALL PERMITTED DEMOLITION ACTIVITY TO BE IN ACCORDANCE WITH APPROVED SITE SAFETY DEMOLITION PLAN & SUCH PLAN TO BE MAINTAINED ON SITE AT ALL TIMES IN ACCORDANCE WITH PHILADELPHIA ADMINISTRATIVE CODE. COMPLETE SIDEWALK CLOSURE REQUIRED AS REFLECTED ON APPROVED SITE PLAN AND IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE STREET CLOSURE PERMIT REQUIRED PRIOR TO START OF WORK. ANY DEVIATION WILL REQUIRE AN AMENDED BUILDING PERMIT.

  5. PermitGeneral Earth Disturbance ONLY

    Permit SP-2025-001191 · Issued

    FOR SITEWORK ONLY AS PER APPROVED PLANS. *SEPARATE PERMITS REQUIRED FOR STRUCTURES.*

  6. PermitAddition and/or Alteration

    Permit EP-2026-003201 · Completed

    Provide all labor, material, equipment, and supervision for the intake pump electrical feed to run one (1) 3” SCH 40 PVC conduit plus one spare 3” SCH 40 PVC conduit from 50 FT. away from the pump to the pump and install one set of 4#350KCMIL and 1#4G 600V wire from the panel in the maintenance building to the pumps in accordance with Cobbs Creek Golf Course Restoration – Water Source plans (attached) and E1.00 Electrical Single Line Diagram and Details (attached) 200amp 208/120v as per 2017 NEC.

  7. PermitSign

    Permit GP-2026-000589 · Issued

    FOR THE ERECTION OF ONE (1) STATIC ILLUMINATED WALL SIGN ON AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK, INCLUDING ALL ELECTRICAL WORK.

  8. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2026-000663 · Issued

    FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED FLAT-WALL SIGNS, (CHANNEL LETTER: 24.974” x 23’-9 ¾” = 49.5 SF) ACCESSORY TO AN EXISTING PARKS AND OPEN SPACE - ACTIVE RECREATION, WITH ALL OTHER SIGNS AS PREVIOUSLY APPROVED; SIZE AND LOCATION AS SHOWN IN THE PLAN.

  9. PermitAddition and/or Alteration

    Permit EP-2025-006738 · Issued

    associated with GP-2025-006244. Supply low voltage power for security fence. Install 3 ground rods, proper bonding and grounding per NEC 2017

  10. PermitFence

    Permit GP-2025-006244 · Expired

    FOR THE INSTALLATION OF 8 FT. HIGH ELECTRIC FENCE IN ACCORDANCE WITH SECTION 9-3800 OF THE PHILADELPHIA CODE. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK. **AMENDMENT 10/9/2025 TO CHANGE THE LOCATIN OF PROPOSED ELECTRIC FENCE.**

  11. PermitMinor Demolition

    Permit DP-2025-000674 · Amendment Application Incomplete

    FOR THE COMPLETE DEMOLITION OF THREE BUILDINGS ONE TWO-STORY STRUCTURE AND TWO ONE-STORY STRUCTURES BY MECHANICAL DEVICES. PEDESTRIAN PROTECTION TO BE IN PLACE PRIOR TO THE START OF WORK AND TO BE MAINTAINED DURING ALL DEMOLITION ACTIVITIES. *21 DAY POSING AND NOTICE REQUIRED PER A-303.2 *A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN MIN. 12 FEET OF BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. *

  12. PermitAddition and/or Alterations

    Permit FP-2025-001312 · Completed

    KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. See hood permit- MP-2024-005969

  13. PermitAlterations

    Permit PP-2025-007732 · Completed

    LATERAL SEAL

  14. PermitSign

    Permit GP-2025-003003 · Expired

    FOR THE ERECTIN OF ONE(1) NON-ILLUMINATED FREESTANDING SIGN AND ONE (1) STATICALLY ILLUMINATED FLAT WALL SIGN. SIZES AND LOCATIONS AS SHOWN ON THE PLAN. SIGNS ACCESSORY TO A PARKS AND OPEN SPACE (ACTIVE RECREATION). SEPARATE PERMIT REQUIRED FOR ELECTRIC.

  15. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2025-002655 · Issued

    FOR THE ERECTIN OF ONE(1) NON-ILLUMINATED FREESTANDING SIGN AND ONE ( 1) STATICALLY ILLUMINATED FLAT WALL SIGN. SIZES AND LOCATIONS AS SHOWN ON THE PLAN.

  16. PermitGeneral Earth Disturbance ONLY

    Permit SP-2024-000783 · Expired

    SITEWORK, GRADING AND EARTH MOVING ACTIVITIES ASSOCIATED WITH CREEK, TRIBUTARY AND FLOODPLAIN RESTORATION FOR AN EXISTING GOLF COURSE FACILITY AS PER APPROVED PLANS AND US ARMY CORPS OF ENGINEERS & PA DEP APPROVALS AND AS PER FEMA CLOMR NO. 24-03-0413R. *2018 IBC REVIEW*

  17. PermitNew construction, addition, GFA change

    Permit ZP-2024-005820 · Issued

    FOR THE COMPLETE DEMOLITION OF FOUR (4) EXISTING DETACHED STRUCTURES AND THE NEW CONSTRUCTION OF THREE (3) DETACHED STRUCTURES. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS. NO SIGN ON THIS APPLICATION.

  18. PermitTemporary Tents and Canopies

    Permit OP-2024-000415 · Expired

    tent for board meeting

  19. PermitFences Only

    Permit ZP-2024-007105 · Completed

    For the fencing installation for the entire cobbs creek golf course restoration project, size and location as shown on the plans.

  20. PermitNew construction, addition, GFA change

    Permit ZP-2024-007104 · Issued

    FOR THE ERECTION OF TWO (2) DETACHED STRUCTURES; FOR USE AS MAINTENANCE FACILITIES ACCESSORY TO PREVIOUSLY APPROVED GOLF COURSE (PARKS AND OPEN SPACE - ACTIVE RECREATION) WITH ALL OTHER USES ON THE SAME PARCEL AS PREVIOUSLY APPROVED; SIZE AND LOCATION AS SHOWN ON THE PLAN.

  21. PermitNew Construction

    Permit EP-2024-005153 · Completed

    Install new 800 amp, 3-Phase, 480/277v service to feed new pump house at Cobbs Creek Golf Club as per 2017 NEC.

  22. PermitSitework with Onsite Utility Services

    Permit SP-2024-000385 · Expired

    SITEWORK ASSOCIATED WITH GOLF COURSE RESTORATION AS PER APPROVED PLANS. **NO WORK WITHIN SPECIAL FLOOD HAZARD AREA ON THIS PERMIT** 2018 IBC REVIEW **SEPARATE PERMIT REQUIRED FOR BUILDING DEMOLITION WORK**

  23. PermitAddition and/or Alteration

    Permit EP-2024-004477 · Completed

    Install lighting and lighting controls, receptacles, HVAC power wiring and tele/data raceways. Install 120/208V 3P 4W 100A Panel RP and 30KVA transformer as per single line on attached electrical drawings as per 2017 NEC. Service is existing. Fire Alarm is not part of this scope.

  24. PermitRough-In

    Permit EP-2024-004500 · Expired

    Rough-In Permit for EP-2024-004477 Install lighting and lighting controls, receptacles, HVAC power wiring and tele/data raceways. Install 120/208V 3P 4W 100A Panel RP and 30KVA transformer as per single line on attached electrical drawings. Fire Alarm is not part of this scope.

  25. PermitNew construction, addition, GFA change

    Permit ZP-2023-012687 · Issued

    FOR THE ERECTION OF A DETACHED STRUCTURE FOR THE SHORT COURSE AREA IN AN EXISTING GOLF COURSE. SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLAN.

  26. PermitSite Clearing or Earth Disturbance ONLY

    Permit ZP-2024-001627 · Issued

    FOR COBBS CREEK GOLF COURSE RESTORATION WITH WORK WITHIN THE FLOODPLAIN. LOCATION AS SHOWN IN PLAN. *FEMA APPROVAL OF THE MODIFICATION TO THE SPECIAL FLOOD HAZARD AREA MUST BE OBTAINED PRIOR TO BUILDING PERMIT ISSUANCE, IN ACCORDANCE WITH SECTION 14-704(4)(F) OF THE PHILADELPHIA ZONING CODE. *

  27. PermitNew Construction

    Permit CP-2023-004053 · Amendment Ready For Issue

    ERECTION OF NEW PUMP HOUSE FOR COBBS CREEK GOLF COURSE. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  28. PermitTank Install/Removal

    Permit GP-2023-008300 · Completed

    **TANK REMOVAL PERMIT** FOR THE REMOVAL OF ONE (1) 550 GALLON UNDERGROUND STORAGE TANK (UST). REMOVE ANY PRODUCT/WATER FROM TANK, CLEAN TANK, CONDUCT A CONFIRMATORY SOIL SAMPLING OF SURROUNDING SOIL. CONTINGENCY PLAN IN PLACE IN THE CASE CONTAMINATED SOILS DISCOVERED AND BACKFILL. ALL WORK TO BE COMPLETED IN ACCORDANCE WITH PA DEP UST REMOVAL GUIDELINES. PROVIDE THE CITY OF PHILADELPHIA WITH A TANK CLOSURE REPORT.

  29. PermitTank Install/Removal

    Permit GP-2023-007575 · Completed

    FOR THE REMOVAL OF ONE (1) 2,000 GALLON TANK. THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP).

  30. PermitNew Construction or Additions

    Permit PP-2023-008780 · Expired

    Plumbing Permit for combo SP-2023-000428

  31. PermitTemporary Tents and Canopies

    Permit OP-2023-000309 · Expired

    tent for groundbreaking event

  32. PermitSitework with Onsite Utility Services

    Permit SP-2023-000428 · Expired

    FOR SITEWORK AS PER APPROVED PLANS.

  33. PermitTemporary Tents and Canopies

    Permit OP-2023-000301 · Expired

    Tent for groundbreaking as per 2018 Philadelphia Fire Code.

  34. PermitNew construction, addition, GFA change

    Permit ZP-2023-002638 · Issued

    FOR THE ERECTION OF A DETACHED STRUCTURE (PUMP HOUSE) AND SITE WORK (IRRIGATION RESERVOIR). SIZE AND LOCATION AS SHOWN ON PLANS.

  35. PermitTemporary Tents and Canopies

    Permit OP-2022-000513 · Expired

    tent for meeting

  36. PermitNew construction, addition, GFA change

    Permit ZP-2022-001367 · Issued

    FOR ERECTION OF THREE (3) DETACHED STRUCTURES (BUILDING A, B & C) AND ONE ACCESSORY STRUCTURE FOR MATERIAL STORAGE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLAN.

  37. AppealZBA Permit Denial - Variance

    Appeal ZP-2022-000047 · Dismissed / Withdrawn · Withdrawn

    Related permit ZP-2022-000047 · PERMIT FOR THE CUTTING TREE ACROSS THE PROPERTY WITHIN THE DEFINED STEEP SLOPE AREAS (STEEP SLOPE IS GREATER THAN 25%) (THE LANDSCAPE AND TREE REQUIREMENTS INCLUDING WITH TREE REPLACEMENT REQUIREMENTS ARE NOT APPLICABLE TO LOTS WITH A PRINC

  38. PermitGeneral Earth Disturbance ONLY

    Permit SP-2021-000939 · Expired

    FOR GENERAL SITE WORK ON A VACANT LOT TO CLEAR SITE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  39. PermitNew construction, addition, GFA change

    Permit ZP-2021-006958 · Issued

    FOR SITE CLEARING WITHIN THE STEEP SLOPE AREA ( NO TREES ARE TO BE REMOVED IN STEEP SLOPE AREA) AS PER CITY PLANNING COMMISSION AND PWD APPROVAL.

  40. License terminal eventCOBBS KARAKUNG GOLD MGT (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license marked closed

    License 441080 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  41. PermitZoning/use

    Permit 794319 · COMPLETED

    FOR THE ERECTION OF A DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR CONTINUED USE AS ACTIVE RECREATION. NO SIGNS OR CHANGES TO PARKING ON THIS APPLICATION.

  42. PermitPlumbing

    Permit 723786 · COMPLETED

    ALTERATION: INTERIOR PLUMBING FOR AN EXISTING MODULAR 1-STORY OFFICE.MODULAR BUILDING (PHILA.GOLF CLUB). THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUMBING CODE, 2004. THE USE OF PLASTIC PIPE IS NOT PERMITED ON THIS PROJECT, PER CODE SECTIONS P-902.5 & P-1102.3.

  43. PermitElectrical

    Permit 723543 · COMPLETED

    WIRE 10- RECEPTACLES AND 6- LIGHTS, AND 4-EMERGENCY/EXIT LIGHTING... IN ACCORDANCE WITH 2008 NEC

  44. PermitMajor alteration

    Permit 682800 · COMPLETED

    FOR THE ERECTION OF A PREFABRICATED ONE STORY MODULAR BUILDING FOR USE AS A TEMPORARY OFFICE TO AN EXISTING GOLF COURSE. ALTERTATIONS TO INCLUDE THE INSTALLATION OF A FOUNDATION SYSTEM, ACCESSIBILITY IMPROVEMENTS AND FINISHES THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. AMENDED PERMIT REQUIRED FOR SPECIAL INSPECTIONS. SEPARATE PERMITS REQUIRED FOR MECHANICAL , ELECTRICAL, AND PLUMBING WORK.

  45. PermitElectrical

    Permit 671350 · COMPLETED

    INSTALL 10 NETWORK CAMERAS AND SOUND DEVICES AS PER NEC 2008 (RECREATION CTR)WEST DISTRICT

  46. InvestigationCSUFINAL

    Case 516143 · PASSED

    The cited inspection visit was marked passed.

  47. InvestigationCSUTESTPIT

    Case 516143 · PASSED

    The cited inspection visit was marked passed.

  48. InvestigationCSUSTUBAR

    Case 516143 · NONE

  49. InvestigationCSUCURBINT

    Case 516143 · PASSED

    The cited inspection visit was marked passed.

  50. InvestigationCSUINITIAL

    Case 516143 · CLOSED

    City marked the record closed; open the case for the closing reason.

  51. ViolationID STRUCTURE

    Case 516143 · Violation 3830512 · Code PM15-110.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  52. ViolationEXTERIOR STRUCT UNSAFE COND 4

    Case 516143 · Violation 3830513 · Code PM15-304.1D · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  53. ViolationEXTERIOR STRUCT UNSAFE COND 8

    Case 516143 · Violation 3830514 · Code PM15-304.1H · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  54. ViolationID STRUCTURE

    Case 516146 · Violation 3816555 · Code PM15-110.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  55. ViolationEXTERIOR STRUCT UNSAFE COND 8

    Case 516146 · Violation 3816556 · Code PM15-304.1H · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  56. ViolationEXTERIOR STRUCT STRUCTURAL MEM

    Case 516146 · Violation 3816557 · Code PM15-304.4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  57. InvestigationCSUINITIAL

    Case 516146 · CLOSED

    City marked the record closed; open the case for the closing reason.

  58. InvestigationCSUFINAL

    Case 516146 · PASSED

    The cited inspection visit was marked passed.

  59. InvestigationCSUINITIAL

    Case 516143 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  60. InvestigationCSUINITIAL

    Case 516146 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  61. PermitAlteration

    Permit 646508 · COMPLETED

    EZ PERMIT RE-ROOFING- FOR THE INSTALLATION OF NEW ROOF COVERINGS ON EXITING ROOFS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  62. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 448674 · PASSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.

  63. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 448674 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  64. ViolationINT COMBUSTIBLE WASTE ACCUMUL

    Case 448674 · Violation 3335555 · Code FC-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  65. ViolationEXT-TREES PRUNE/REMOVE

    Case 448674 · Violation 3335556 · Code PM-312.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  66. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 448674 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  67. InvestigationCI INSP

    Case 303254 · PASSED

    The cited inspection visit was marked passed.

  68. PermitElectrical

    Permit 413542 · COMPLETED

    INSTALL FIRE ALARM SYSTEM EMERGENCY LIGHTING REPLACE PER 2008 NFPA 72

  69. InvestigationCI INSP

    Case 303254 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  70. ViolationCOMBUS FIBR-REMOV GRASS/WEEDS

    Case 303254 · Violation 2341322 · Code FC-304.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  71. InvestigationCI INSP

    Case 303254 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  72. ViolationVIOL C&I MESSAGE

    Case 303254 · Violation 2341321 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  73. InvestigationCI INSP

    Case 303254 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  74. License terminal eventLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Dumpster License - Private Property L&I license filing marked inactive

    License 354280 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  75. PermitMajor alteration

    Permit 215856 · COMPLETED

    REPLACING BRIDGE TO #6 TEE THAT WAS DESTROYED IN A STORM.NO DISRUPTION OF EARTH ON THIS PROJECT USING EXISTING FOUNDATIONS AS PER PLAN.

  76. PermitDemolition

    Permit 211935 · COMPLETED

    REMOVAL OF 2000 GALLON UNDERGROUND STORAGE TANK FORMERLY USED FOR HEATING OIL STORAGE WITHH PLANNED BACKFILL WITH CLEAN FILL AND RESURFACING OF DISTURBED AREA WITH ASPHALT PAVEMENT

  77. PermitZoning/use

    Permit 215869 · COMPLETED

    FOR THE REPLACEMENT OF A FOOTBRIDGE ACROSS COBBS CREEK UTILIZING EXISTING FOUNDATIONS AS PART OF AN EXISTING RECREATIONAL FACILITY. SIZE AND LOCATION AS SHOWN IN THE APPLICATION.EXISTING RECREATIONAL FACILITY.

  78. License issue eventCOBBS KARAKUNG GOLD MGT (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license initially issued

    License 441080 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  79. License terminal eventLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license marked inactive

    License 352634 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  80. InvestigationBC INSP (likely: building-code inspection)

    Case 128616 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  81. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 128616 · Violation 682537 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.

  82. InvestigationBC INSP (likely: building-code inspection)

    Case 128616 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  83. License issue eventLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Food Preparing and Serving business license initially issued

    License 352634 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  84. License issue eventLIBERTY GOLF CONSULTING INC (COBBS CREEK GOLF CLUB): Dumpster License - Private Property L&I license filing initially issued

    License 354280 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  85. PermitNew construction, addition, GFA change

    Permit ZP-2022-000047 · Refused

Where this comes from

Methodology & freshness

This report was assembled Jul 28, 2026, 1:24 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)