Industrial property report

7425 State Rd

2 stories85,350 sqftI2built 2006

Property at a glanceIndustrial

State Road Storage LP

2026 assessment
$7.0M OPA value, not a listing price
2027 published assessment
$9.4M Future roll, not the current tax bill
Neighborhood area
Holmesburg · Mayfair Approximate · based on ZIP 19136
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $9,388,500. It is not yet the billed-year tax basis.

$0$5.0M$10M$9.4M2006201020142018202220262027
Property assessmentAssessmentL&I violationPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record46 events · exact dates, newest first
  1. CertificationSprinkler Certification
  2. CertificationSprinkler Certification
  3. LicenseT-Mobile USA Inc: Hazardous Materials L&I license filing initially issued
  4. PermitAddition and/or Alterations
  5. PermitAddition and/or Alteration
  6. PermitAddition and/or Alteration
  7. PermitPlumbing
  8. PermitSuppression
  9. PermitElectrical
  10. PermitMajor alteration
  11. PermitMechanical
  12. PermitZoning/use
  13. PermitMajor alteration
  14. PermitSuppression
  15. InspectionBC INSP (likely: building-code inspection)
  16. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  17. InspectionBC INSP (likely: building-code inspection)
  18. PermitElectrical
  19. PermitPlumbing
  20. PermitMajor alteration
  21. PermitMechanical
  22. PermitElectrical
  23. PermitZoning/use
  24. PermitSuppression
  25. InspectionBP_BLDG
  26. PermitElectrical
  27. L&I violationPENALTY- NO ELEC PERM INFO
  28. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  29. InspectionBP_BLDG
  30. PermitSign
  31. PermitZoning/use
  32. L&I violationVIOL BC MESSAGE
  33. InspectionBC INSP (likely: building-code inspection)
  34. InspectionBP_BLDG
  35. L&I violationPERMB- INSTALL HVAC SYS
  36. InspectionBP_BLDG
  37. PermitElectrical
  38. PermitAdministrative
  39. PermitElectrical
  40. PermitMajor alteration
  41. PermitMechanical
  42. PermitMechanical
  43. PermitZoning/use
  44. InspectionBC INSP (likely: building-code inspection)
  45. LicenseSTATE ROAD STORAGE LP: Dumpster License - Private Property L&I license filing initially issued
  46. InspectionBC INSP (likely: building-code inspection)

Verify the public record

$97,986/year estimated property tax

2026 taxable assessment $7,000,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $9,388,500. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 884256025
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Industrial property

Industrial, recorded in the City's industrial category. The public record and owner trail follow.

What it is
Industrial Ind Bldg Mini Whse Mas+O
Owner
State Road Storage LP
$ / sq ft
$110 above the $70 median for 3,574 industrial parcels citywide
Interior area
85,350 sqft
Lot size
226,380 sqft
Stories
2
Built
2006
Zoning
I2

Recorded owner

Who's behind it

State Road Storage LP · corporate / LLC owner

• Owns 2 properties across Philadelphia under this name, assessed at $10M combined
• Tax bills mail to 7425 State Rd, Philadelphia PA, 19136

Block context

7400 block of State Rd. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 7401 State Rd  ·  7430 State Rd

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 23, 2026.

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 46 dated rows
  1. CertificationSprinkler Certification

    Certification BC-2025-005422 · Certified

    Expires 2025-09-05

  2. CertificationSprinkler Certification

    Certification BC-2022-019504 · Certified

    Expires 2023-09-13

  3. License issue eventT-Mobile USA Inc: Hazardous Materials L&I license filing initially issued

    License 863804 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  4. PermitAddition and/or Alterations

    Permit MP-2020-001573 · Expired

    FOR HVAC MECHANICAL INSTALLATIONS TO INCLUDE ACCU'S, GRILLES/REGISTERS/DIFFUSERS, ASSOCIATED DUCTWORK AND EQUIPMENT PAD INSTALLATION.

  5. PermitAddition and/or Alteration

    Permit EP-2020-002141 · Completed

    Project Objective: Provide (2) new 225A panels fed out of 600A MDP with branch circuit wiring for (20) new 1Ph, 208V, 30A rectifiers. Have new panels ready and branch circuitry terminated to new rectifiers for quick cut-over, minimizing downtime. Load on existing service will not be altered, as (20) existing rectifiers and their branch circuitry will be removed after cut-over to the new (20) rectifiers is complete. Scope Items: 1. Tap an existing 225A, 208/120V feed for panel PP1 to refeed panel PP2. Utilize existing PP2 225A OCPD for feeding a new 225A panel (PP6) 2. Tap an existing 225A, 208/120V feed for panel PP3 to refeed panel PP4. Utilize existing PP4 225A OCPD for feeding new 225A panel (PP7) 3. Provide (2) new 3Ph, 225A, 208/120V panels (PP6 and PP7) for feeding new rectifiers. (10) rectifiers to be fed out of PP6 and (10) rectifiers to be fed out of PP7. 4. Install new 1Ph, 100A, 240/120V Inverter panel, fed from output of rectifiers and inverter. 5. Refeed (3) 20A critical loads off from new Inverter panel and demo old feeds from existing inverter panel.ALL WORK TO BE DONE ACCORDING TO'17 NEC.

  6. PermitAddition and/or Alteration

    Permit EP-2020-004135 · Issued

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  7. PermitPlumbing

    Permit 1032582 · COMPLETED

    EXTEND DRAIN AND WATER TO ACCOMMODATE NEWBATH ROOM. INSTALL FIXTURES; TOILET, LAV, AND SHOWER AS PER PHILADELPHIA 2014 PLUMBING CODE.

  8. PermitSuppression

    Permit 1029471 · COMPLETED

    ALTERATIONS TO EXISTING NFPA 13 SPRINKLER SYSTEM TO ACCOMODATE NEW FIRST FLOOR LAYOUT IN AN EXISTING STORAGE FACILITY AS PER APPROVED PLANS. NO WORK TO EXISTING SPRINKLER RISER OR MAIN SERVICE. ALL WORK TO BE PERFORMED BY PHILADELPHIA LICENSED FIRE SUPPRESSION CONTRACTOR.

  9. PermitElectrical

    Permit 1029967 · COMPLETED

    ALTERATION BEDROOM AND BATHROOM FOR CARE TAKER. SIXTEEN(16) OUTLETS, SWITCHES, CEILING FAN, EXHAUST FAN, VANITY LIGH FIXTURE, RECESSED SHOWER LIGHT,TWO(2) SMOKE ALARMS, AND ARCH FAULT FOR BEDROOM CIRCUIT AS PER 2014 NEC.

  10. PermitMajor alteration

    Permit 1024075 · COMPLETED

    FOR INTERIOR ALTERATIONS TO EXISTING STORAGE FACILITY, TO INCLUDE NEW INTERIOR PARTITIONS AND INTERIOR FINISHES, TO CREATE AN ACCESSORY OFFICE AND DWELLING UNIT FOR USE BY CARETAKER ONLY, AS PER APPROVED PLANS.

  11. PermitMechanical

    Permit 1027943 · COMPLETED

    FOR MECHANICAL ALTERATIONS TO INCLUDE NEW REGISTERS/DIFFUSERS TO NEW RESIDENTIAL UNIT, WITHIN THE EXISTING STORAGE FACILITY, AS PER APPROVED PLANS. SEE APP# 1024075 FOR APPROVED PLANS.

  12. PermitZoning/use

    Permit 1021055 · COMPLETED

    FOR THE ERECTION OF A ONE (1) STORY STRUCTURE IN AN EXISTING STORAGE FACILITY; FOR USE AS AN EXISTING ACCESSORY OFFICE AND DWELLING FOR USE BY CARETAKER ONLY IN AN EXISTING STORAGE FACILITY; SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLAN.

  13. PermitMajor alteration

    Permit 834113 · COMPLETED

    FOR THE INSTALLATION OF ONE (1) EXTERIOR DOOR AND CONCRETE PATIO (<12" ABOVE GRADE), TO AN EXISTING STORAGE FACILITY, AS PER PLANS; NO OTHER WORK ON THIS PERMIT.

  14. PermitSuppression

    Permit 820188 · COMPLETED

    INSTALLATION OF FM-200 CLEAN AGENT FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2001.

  15. InvestigationBC INSP (likely: building-code inspection)

    Case 391843 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  16. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 391843 · Violation 2864904 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.

  17. InvestigationBC INSP (likely: building-code inspection)

    Case 391843 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  18. PermitElectrical

    Permit 416598 · COMPLETED

    INSTALL A NEW 220 VOLT PANEL PER 2008 NEC

  19. PermitPlumbing

    Permit 414466 · COMPLETED

    REPLACE 3/4" WATER SERVICE FROM MAIN IN STREET TO METER

  20. PermitMajor alteration

    Permit 411878 · COMPLETED

    INTERIOR ALTERATIONS FOR THE EXPANSION OF AN EXISTING WIRELESS/MOBILE TENANT SPACE INCLUDING STRUCTURAL MODIFICATIONS, NEW MASONRY WALL OPENINGS FOR MECHANICAL EQUIPMENT, AND THE CONSTRUCITON OF FOUR CONCRETE EQUIPMENT PADS FOR A RELOCATED GLYCOOL PUMP AND CONDINSING UNIT AND TWO NEW OUTDOOR AC UNITS.

  21. PermitMechanical

    Permit 412137 · COMPLETED

    FOR THE MODIFICATION AND EXTENSION OF AN EXISTING HVAC SYSTEM, INSTALLATION OF 2 OUTDOOR AC UNITS AND RELOCATION OF AN EXISTING GLYCOOL PUMP AND CONDENSING UNIT AS PART OF AN EXPANSION OF AN EXISTING WIRELESS/MOBILE TENANT SPACE IN AN EXISTING STORAGE FACILITY. SEE GENERAL CONSTRUCTION PERMIT AP #411878 FOR PLANS

  22. PermitElectrical

    Permit 412143 · COMPLETED

    INSTALL 3 SWITCHES, 6 OUTLETS, AND 6 OVERHEAD LIGHTS AS PER 2008 NEC(SFD)(EAST DIST)

  23. PermitZoning/use

    Permit 392078 · COMPLETED

    RELOCATION OF EXISTING ACCESSORY OUTDOOR EQUIPMENT,INCLUDING DRYCOOLER, INSTALLATION OF (2) OURDOOR AIR CONDITIONING UNITS AND CHAIN LINK FENCE.

  24. PermitSuppression

    Permit 388140 · COMPLETED

    RELOCATION OF (18) EXISTING FIRE SPRINKLERS

  25. InvestigationBP_BLDG

    Case 273238 · PASSED

    The cited inspection visit was marked passed.

  26. PermitElectrical

    Permit 339883 · COMPLETED

    STORAGE BUILDING- SIGN ONLY... POWER WIRE AND SIGN, 208V, 20AMP, SINGLE PHASE AND TIME CLOCK.... IN ACCORDANCE WITH 2008 NEC

  27. ViolationPENALTY- NO ELEC PERM INFO

    Case 273238 · Violation 2042645 · Code A-901.13/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 273238 · Violation 2042644 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. InvestigationBP_BLDG

    Case 273238 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  30. PermitSign

    Permit 325722 · COMPLETED

    INSTALL PYLON SIGN,POST, FOOTING, AND LED MESSAGE SIGN

  31. PermitZoning/use

    Permit 323669 · COMPLETED

    INSTALL (1) PYLON SIGN, CABINET WITH LED FOR STORAGE FACILITY.

  32. ViolationVIOL BC MESSAGE

    Case 193541 · Violation 1264015 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  33. InvestigationBC INSP (likely: building-code inspection)

    Case 193541 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  34. InvestigationBP_BLDG

    Case 186465 · PASSED

    The cited inspection visit was marked passed.

  35. ViolationPERMB- INSTALL HVAC SYS

    Case 186465 · Violation 1171335 · Code A-301.1/46 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  36. InvestigationBP_BLDG

    Case 186465 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  37. PermitElectrical

    Permit 161830 · COMPLETED

    NEW FIRE ALARM SYSTEM AS PER NFPA72 (EAST DISTRICT)

  38. PermitAdministrative

    Permit 157869 · COMPLETED

    AMEND/REVISE PERMIT NO. 148181, OPTION NOT TO INSTALL NON-CODE REQUIRED SUPRESSION SYSTEM IN AREA INDICATED ON PLANS F1

  39. PermitElectrical

    Permit 150131 · COMPLETED

    WIRE TELE COMMUNICATION FACILITY TO PLAN, AS PER 2005 NEC, AND ROUGH WIRE (EAST DIST)

  40. PermitMajor alteration

    Permit 148181 · COMPLETED

    INTERIOR/EXTERIOR ALTERATIONS, CONSTRUCT NEW GENERATOR CONCRETE PAD & ROOM FOR TELEPHONE SWITCH ROOM, FENCING, AS PER SUBMITTED PLANS.

  41. PermitMechanical

    Permit 148543 · EXPIRED

    INTERIOR/EXTERIOR ALTERATIONS, INSTALL NEW DUCTWORK, DIFFUSERS, ACCESSORY MECHANICALS, AS PER PLANS.

  42. PermitMechanical

    Permit 148026 · COMPLETED

    LIBERTY AIR CONDITIONER WITH ACCESSORY DUCTWORK LESS THAN 2000 CFM (BUILDING #4)

  43. PermitZoning/use

    Permit 146625 · COMPLETED

    STORAGE FACILITY W/ADDITION OF MOBIL TELEPHONE SWITCH ROOM W/ACCESSORY BACKUP GENERATOR (FENCE IN-8'H) & CONDENSER UNIT

  44. InvestigationBC INSP (likely: building-code inspection)

    Case 86264 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  45. License issue eventSTATE ROAD STORAGE LP: Dumpster License - Private Property L&I license filing initially issued

    License 390389 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  46. InvestigationBC INSP (likely: building-code inspection)

    Case 86264 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 6:50 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)