Property report

7500 Central Ave

290,454 sqftRSA1built 1970

Property at a glanceCommercial

Individual owner on record

2026 assessment
$55M OPA value, not a listing price
2027 published assessment
$55M Future roll, not the current tax bill
Neighborhood area
Fox Chase · Burholme Approximate · based on ZIP 19111
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $55,013,500. It is not yet the billed-year tax basis.

$0$50M$100M$55M2005200920132017202120252027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record233 events · exact dates, newest first
  1. PermitAddition and/or Alteration
  2. PermitAddition and/or Alteration
  3. PermitAddition and/or Alteration
  4. PermitAlterations
  5. CertificationFire Alarm Certification
  6. PermitAddition and/or Alteration
  7. PermitRough-In
  8. PermitAddition and/or Alterations
  9. PermitAddition and/or Alteration
  10. PermitAddition and/or Alteration
  11. PermitAddition and/or Alteration
  12. InspectionL&I investigation
  13. PermitAddition and/or Alterations
  14. InspectionL&I investigation
  15. L&I violationBENCHMARKING LATE
  16. PermitAddition and/or Alterations
  17. PermitAlterations
  18. PermitAddition and/or Alteration
  19. CertificationFire Alarm Certification
  20. PermitAddition and/or Alteration
  21. PermitAddition and/or Alteration
  22. CertificationSprinkler Certification
  23. PermitAddition and/or Alteration
  24. CertificationSprinkler Certification
  25. PermitAddition and/or Alterations
  26. PermitAddition and/or Alterations
  27. PermitAddition and/or Alteration
  28. PermitAddition and/or Alteration
  29. PermitAlterations
  30. PermitAddition and/or Alteration
  31. CertificationFire Alarm Certification
  32. PermitAddition and/or Alteration
  33. PermitAddition and/or Alterations
  34. PermitAddition and/or Alterations
  35. PermitAddition and/or Alteration
  36. PermitAddition and/or Alterations
  37. PermitInterior Non-Load-Bearing Wall Demo.
  38. CertificationSprinkler Certification
  39. PermitAddition and/or Alterations
  40. CertificationSprinkler Certification
  41. PermitAddition and/or Alteration
  42. PermitAddition and/or Alteration
  43. PermitAddition and/or Alteration
  44. PermitAddition and/or Alteration
  45. PermitAlterations
  46. PermitAddition and/or Alterations
  47. PermitAddition and/or Alteration
  48. CertificationFire Alarm Certification
  49. PermitAddition and/or Alteration
  50. CertificationFire Alarm Certification
  51. CertificationFire Alarm Certification
  52. PermitAddition and/or Alteration
  53. PermitAddition and/or Alterations
  54. PermitNew Construction or Additions
  55. PermitAlterations
  56. CertificationSpecial Hazards Certification
  57. PermitNew Construction
  58. PermitAddition and/or Alterations
  59. PermitAddition and/or Alteration
  60. PermitNew Construction
  61. PermitAddition and/or Alteration
  62. PermitAddition and/or Alteration
  63. PermitAddition and/or Alterations
  64. PermitAlterations
  65. CertificationFire Alarm Certification
  66. AppealZBA Permit Denial - Special Exception
  67. PermitAddition and/or Alteration
  68. PermitAddition and/or Alteration
  69. PermitNew construction, addition, GFA change
  70. CertificationFacade Report
  71. CertificationSpecial Hazards Certification
  72. CertificationFire Alarm Certification
  73. CertificationFire Alarm Certification
  74. PermitAlterations
  75. PermitAddition and/or Alteration
  76. PermitAddition and/or Alteration
  77. PermitAddition and/or Alteration
  78. PermitAddition and/or Alterations
  79. PermitAlterations
  80. PermitAddition and/or Alteration
  81. CertificationSprinkler Certification
  82. CertificationSprinkler Certification
  83. CertificationSprinkler Certification
  84. PermitAddition and/or Alteration
  85. PermitAlterations
  86. PermitAddition and/or Alterations
  87. PermitAddition and/or Alteration
  88. PermitAddition and/or Alterations
  89. PermitRoof Covering Replacement
  90. CertificationFire Alarm Certification
  91. PermitAddition and/or Alteration
  92. PermitAddition and/or Alteration
  93. PermitAlterations
  94. PermitAddition and/or Alteration
  95. PermitNew Construction
  96. LicenseJEANES HOSPITAL: Annual Small Games Of Chance business license marked inactive
  97. PermitElectrical
  98. PermitMechanical
  99. PermitPlumbing
  100. PermitAddition and/or Alteration
  101. PermitNew Construction
  102. PermitSuppression
  103. InspectionCI INSP
  104. InspectionCI INSP
  105. L&I violationCERTIFICATION
  106. InspectionCI INSP
  107. PermitPlumbing
  108. PermitSuppression
  109. PermitSuppression
  110. PermitElectrical
  111. PermitElectrical
  112. PermitElectrical
  113. PermitMechanical
  114. PermitPlumbing
  115. PermitAddition
  116. PermitMajor alteration
  117. PermitMajor alteration
  118. PermitMechanical
  119. PermitZoning/use
  120. AppealZoning board appeal
  121. PermitPlumbing
  122. PermitSuppression
  123. PermitMajor alteration
  124. PermitElectrical
  125. PermitMechanical
  126. PermitPlumbing
  127. PermitPlumbing
  128. PermitMajor alteration
  129. PermitElectrical
  130. PermitMajor alteration
  131. PermitAlteration
  132. LicenseJEANES HOSPITAL: Dumpster License - Private Property L&I license filing marked inactive
  133. InspectionCI INSP
  134. L&I violationVIOL C&I MESSAGE
  135. L&I violationFA-REPAIR SYSTEM
  136. L&I violationANNUAL CERT FIRE ALARM
  137. L&I violationFIRE-PULL STATION SIGNS
  138. InspectionCI INSP
  139. PermitElectrical
  140. PermitSuppression
  141. PermitAlteration
  142. PermitMajor alteration
  143. PermitPlumbing
  144. PermitZoning/use
  145. PermitMechanical
  146. PermitMajor alteration
  147. PermitOperations
  148. PermitMechanical
  149. PermitElectrical
  150. L&I violationPERMB- WK DONE W/O NOTIFY INSP
  151. PermitSuppression
  152. L&I violationPERMB- WK DONE W/O NOTIFY INSP
  153. L&I violationPERMB- WK DONE W/O NOTIFY INSP
  154. PermitPlumbing
  155. PermitMajor alteration
  156. PermitDemolition
  157. PermitOperations
  158. PermitPlumbing
  159. PermitElectrical
  160. PermitSuppression
  161. PermitMechanical
  162. PermitMajor alteration
  163. PermitElectrical
  164. InspectionCI INSP
  165. LicenseJEANES HOSPITAL: Dumpster License - Private Property L&I license filing initially issued
  166. InspectionCI INSP
  167. LicenseJEANES HOSPITAL: Annual Small Games Of Chance business license initially issued
  168. LicenseJEANES HOSPITAL: Monthly Small Games of Chance business license initially issued
  169. PermitPlumbing
  170. InspectionCI INSP
  171. PermitSuppression
  172. PermitMajor alteration
  173. InspectionBP_BLDG
  174. PermitSuppression
  175. PermitMajor alteration
  176. InspectionCI INSP
  177. PermitMajor alteration
  178. PermitAdministrative
  179. PermitAdministrative
  180. PermitOperations
  181. L&I violationPERMB- EXTEND FIRE SUPP SYS
  182. InspectionBP_BLDG
  183. PermitOperations
  184. PermitMechanical
  185. PermitMajor alteration
  186. PermitElectrical
  187. PermitElectrical
  188. PermitPlumbing
  189. PermitSuppression
  190. PermitSuppression
  191. PermitPlumbing
  192. L&I violationANNUAL CERT FIRE ALARM
  193. InspectionCI INSP
  194. PermitMajor alteration
  195. PermitDemolition
  196. PermitOperations
  197. PermitSuppression
  198. PermitMajor alteration
  199. PermitElectrical
  200. PermitElectrical
  201. InspectionCI INSP
  202. PermitElectrical
  203. PermitMechanical
  204. PermitElectrical
  205. PermitPlumbing
  206. PermitSuppression
  207. PermitMajor alteration
  208. PermitFast form building
  209. PermitElectrical
  210. PermitDemolition
  211. PermitMajor alteration
  212. PermitMajor alteration
  213. PermitPlumbing
  214. PermitElectrical
  215. PermitDemolition
  216. PermitAdministrative
  217. PermitElectrical
  218. L&I violationVIOL C&I MESSAGE
  219. L&I violationANNUAL CERT FIRE SUPP
  220. InspectionCI INSP
  221. PermitOperations
  222. PermitNew construction
  223. PermitElectrical
  224. PermitFast form building
  225. PermitMajor alteration
  226. PermitElectrical
  227. PermitOperations
  228. PermitMajor alteration
  229. PermitZoning
  230. PermitZoning/use
  231. PermitElectrical
  232. PermitSign
  233. LicenseJEANES HOSPITAL: Food Preparing and Serving (30+ SEATS) business license initially issued

Verify the public record

$53,206/year estimated property tax

2026 taxable assessment $3,800,997 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $55,013,500. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 778024500
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $3,800,997 of $55,013,500 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

What it is
Commercial Health Fac Hosp Mas+Oth
Owner
Individual owner on record Individual name redacted
$ / sq ft
$189 above the $151 median for 7,668 commercial parcels citywide
Interior area
290,454 sqft
Lot size
2,550,874 sqft
Built
1970
Zoning
RSA1

Block context

7500 block of Central Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
JEANES HOSPITALInactive

Annual Small Games Of Chance · Initial issue date Dec 7, 2010 · Terminal license date Dec 30, 2019

JEANES HOSPITALInactive

Monthly Small Games of Chance · Initial issue date Dec 7, 2010

JEANES HOSPITALActive

Food Preparing and Serving (30+ SEATS) · Initial issue date Nov 29, 2005 · Filed expiration Apr 30, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 233 dated rows
  1. PermitAddition and/or Alteration

    Permit CP-2026-002593 · Issued

    FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, FIXTURES, EQUIPMENT, FURNISHING, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  2. PermitAddition and/or Alteration

    Permit EP-2026-001883 · Completed

    Provide and install two (2) wall-mounted fire alarm strobe notification appliances in the jeans X-ray replacement area. Work includes all required wiring, mounting, terminations, and connection to the fire alarm system. All work to be done according to the 2017 NEC, 2016 NFPA 72 and per approved plans.

  3. PermitAddition and/or Alteration

    Permit EP-2026-003063 · Completed

    STATEMENT OF WORK: HORIZONTAL CABLING: Cabling will be Superior/Essex Category 6A plenum rated 4-pair and CommScope RG6 quad shield plenum rated coax.. • Provide labor to demo/remove all Category 5/6/6A cables in scope area. Demo scope for this project includes removal of existing wall mount bracket and surface mount boxes for existing horizontal cabling in the existing IDF. • Provide and install two (2) flush mount quad Category 6A locations. • Provide and install nine (9) flush mount triple Category 6A locations. • Provide and install twenty (20) flush mount dual Category 6A locations. • Provide and install seven (7) surface mount single Category 6A wireless access point locations. • Provide labor to install seven (7) customer-provided wireless access points. • Provide and install seven (7) single Category 6A surface mount CCTV locations. • Provide and install three (3) flush mount triple (2 Category 6A/1 coax) TV locations. • Provide and install two (2) single Category 6A flush mount locations. • Provide and install Ortronics faceplates, surface mount boxes, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables at the workstation location. • Provide and install three (3) Ortronics 48-port modular patch panels, each loaded with the required modular jacks. These will be installed in the appropriate closet location for termination of the 4-pair cables installed. COPPER BACKBONE CABLING: (AFTER HOURS) • Provide labor to relocate existing 50-pair cable from existing Teledata IDF to the new IDF on the same floor. • Re-use of any backbone cable assumes the lengths of these cables are adequate and in proper condition to be re-used in the new IDF. FIBER BACKBONE CABLING: (AFTER HOURS) • Provide labor to relocate existing 12-strand fiber optic cable from existing Teledata IDF to the new IDF on the same floor. • Re-use of any backbone cable assumes the lengths of these cables are adequate and in proper con

  4. PermitAlterations

    Permit PP-2026-001249 · Completed

    ALTERATIONS TO EXISTING OFFICE SPACE. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATERIALS SHALL BE METALLIC TO ROOF EXTENSION. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS

  5. CertificationFire Alarm Certification

    Certification BC-2026-010633 · Certified

    Expires 2027-03-19

  6. PermitAddition and/or Alteration

    Permit EP-2026-001150 · Completed

    install 13 light fixtures, 6 switches, 9 receptacles and raceways for xray ***NO FIRE ALARM ON THIS PERMIT***

  7. PermitRough-In

    Permit EP-2026-001259 · Issued

    Rough-In Permit for EP-2026-001254 Install (13) Light fixtures (6) switches, (9) receptacles and raceways for X-ray machine

  8. PermitAddition and/or Alterations

    Permit MP-2026-000804 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. **AMENDMENT (4-23-2026) ADDING A FUEL GAS PIPING SYSTEM PER THE APPROVED AMENDED CONSTRUCTION DOCUMENTS.

  9. PermitAddition and/or Alteration

    Permit EP-2026-000739 · Completed

    Provide demolition and temporary power and lighting as required for construction activities. Install new branch circuitry, new permanent lighting and lighting control systems, including exit signs and emergency lighting. Install telecommunication wiring and receptacle outlets throughout the space. Furnish and install one (1) 100-amp subpanel and one (1) 225-amp subpanel, including feeders, overcurrent protection, grounding, and bonding, All work to be done according to the 2017 NEC and per approved plans.

  10. PermitAddition and/or Alteration

    Permit CP-2026-000149 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE AT SUITE 106 & 108 ON GROUND FLOOR. ALTERATIONS TO INCLUDE PARTIAL DEMOLITION AND THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. ***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************

  11. PermitAddition and/or Alteration

    Permit EP-2025-011163 · Completed

    Electrical demolition of an existing ceiling and install new lighting and make electrical connections on an operating boom. We are to run one new circuit in type EMT conduit for a boom light and it's associated control panel. We are also running type EMT conduit for(10) new downlights using the existing circuits.-2017 NEC.

  12. InvestigationL&I investigation

    Case CF-2025-134443 · PASSED

    The cited inspection visit was marked passed.

  13. PermitAddition and/or Alterations

    Permit MP-2025-006095 · Issued

    FORA MECHANICAL SYSTEM UPGRADE TO AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.

  14. InvestigationL&I investigation

    Case CF-2025-134443 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  15. ViolationBENCHMARKING LATE

    Case CF-2025-134443 · Violation VI-2025-097583 · Code 9-3402(2) · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  16. PermitAddition and/or Alterations

    Permit MP-2025-006230 · Completed

    FOR THE INSTALLATION OF REGISTERS / DIFFUSERS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  17. PermitAlterations

    Permit PP-2025-015695 · Completed

    REPLACE ONE LAVATORY.

  18. PermitAddition and/or Alteration

    Permit CP-2025-005197 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ASBESTOS ABATEMENT REQUIRED PRIOR TO THE START OF WORK. DOH APPROVAL UNDER DWG. INDEX H-25-0369 AND ID #200701-21.

  19. CertificationFire Alarm Certification

    Certification BC-2026-000204 · Certified

    Expires 2026-12-02

  20. PermitAddition and/or Alteration

    Permit CP-2025-004543 · Issued

    FOR LEVEL I ALTERATIONS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK.

  21. PermitAddition and/or Alteration

    Permit EP-2025-007069 · Completed

    Upgrade the fire alarm system including NAC devices and Initiating devices in Founders Building, Patient Care Center, Heart and Surgery Center as per 2016 NFPA 72.

  22. CertificationSprinkler Certification

    Certification BC-2025-023518 · Certified

    Expires 2026-08-28

  23. PermitAddition and/or Alteration

    Permit EP-2025-006494 · Completed

    INSTALL TELECOMMUNICATION WIRING. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC.

  24. CertificationSprinkler Certification

    Certification BC-2025-020157 · Certified

    Expires 2026-07-22

  25. PermitAddition and/or Alterations

    Permit MP-2025-002013 · Completed

    FOR THE INSTALLATION OF REGISTERS AND DIFFUSERS WITH ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. *NO APPLIANCES ON THIS PERMIT.

  26. PermitAddition and/or Alterations

    Permit FP-2025-001392 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 70 EXISTING SPRINKLER HEADS TO ACCOMODATE NEW PHARMACY LAYOUT

  27. PermitAddition and/or Alteration

    Permit EP-2025-004697 · Completed

    INSTALL TELECOMMUNICATIONS WIRING AND SYSTEM ACCORDING TO THE 2017 NEC.

  28. PermitAddition and/or Alteration

    Permit EP-2025-004439 · Completed

    Install (81) Fixtures, (125) electrical devices, (18) Equipment connections, (15) Mechanical Equipment connections, (4) ATS's, (7) electrical panels and (2) Transformers as per 2017 NEC. Add (19) detectors, (12) speaker/strobes, (9) strobes, and (2) pull stations to existing fire alarm system .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 IEBC.

  29. PermitAlterations

    Permit PP-2025-004533 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  30. PermitAddition and/or Alteration

    Permit EP-2025-002168 · Completed

    Equipment replacement of 400 KW generator serving Heart & Surgery building at Jeanes Hospital. Equipment replacement of four automatic transfer switches associated with emergency generator. All new equipment to be like in kind. There is no commercial building permit associated with this equipment replacement project. Installation to conform to 2017 NEC.

  31. CertificationFire Alarm Certification

    Certification BC-2025-010595 · Certified

    Expires 2026-03-28

  32. PermitAddition and/or Alteration

    Permit CP-2025-000489 · Completed

    FOR LEVEL II ALTERATIONS WITH NO CHANGE IN OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.

  33. PermitAddition and/or Alterations

    Permit MP-2024-004936 · Completed

    FOR THE INSTALLATION OF A NEW HVAC SYSTEMS, ASSOCIATED DUCT WORK, ROOFTOP UNITS, EXHAUST FANS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION.

  34. PermitAddition and/or Alterations

    Permit FP-2024-002196 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 26 existing sprinkler heads to accommodate new layout

  35. PermitAddition and/or Alteration

    Permit EP-2024-005743 · Completed

    Demo existing lighting and receptacles, Provide new lighting package and receptacles. Provide power to fan coil units. Installation shall comply with 2017 NEC.

  36. PermitAddition and/or Alterations

    Permit MP-2024-002072 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  37. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2024-007791 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  38. CertificationSprinkler Certification

    Certification BC-2024-024672 · Certified

    Expires 2025-08-29

  39. PermitAddition and/or Alterations

    Permit FP-2024-001580 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (19) SPRINKLER HEADS AS PER NFPA 13

  40. CertificationSprinkler Certification

    Certification BC-2024-021798 · Certified

    Expires 2025-07-24

  41. PermitAddition and/or Alteration

    Permit CP-2024-003200 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING HOSPITAL OCCUPANC. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS AND PROVIDE FINISHES/FURNISHINGS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  42. PermitAddition and/or Alteration

    Permit EP-2024-006264 · Completed

    HORIZONTAL CABLING – MAIN HOSPITAL: Cabling will be Superior/Essex Category 6+ plenum rated 4-pair for network applications and Superior/Essex Category 6A plenum rated 4-pair for wireless applications. ? Provide and install three (3) surface mount single wireless access point locations. ? Provide labor to install three (3) customer-provided wireless access points. ? Provide and install forty-one (41) surface mount single TV locations. ? Provide and install Ortronics faceplates, surface mount boxes and modular jacks as required for termination of the 4-pair cables at the workstation location. ? Provide and install two (2) Ortronics 48-port modular patch panels, each loaded with the required modular jacks. These will be installed at the appropriate closet location for termination of the 4-pair cables installed. ? Provide and install two (2) Ortronics 2RU single-sided horizontal cable managers with the patch panels to facilitate cable management. ? Provide and install fifteen (15) flush mount single locations. ? Provide and install Ortronics faceplates and modular jacks as required for termination of the 4-pair cables at the workstation location. ? Provide and install two (2) Ortronics 48-port modular patch panel loaded with the required modular jacks. This will be installed at the appropriate closet location for termination of the 4-pair cables installed. ? Provide and install one (1) Ortronics 2RU single-sided horizontal cable manager with the patch panel to facilitate cable management. All work in accordance with the 2017 nec.

  43. PermitAddition and/or Alteration

    Permit EP-2024-004470 · Completed

    Replacement of lighting fixtures and controls. Replace multiple electrical circuits.

  44. PermitAddition and/or Alteration

    Permit CP-2024-002382 · Issued

    FOR A CONCRETE REPAIR TO AN EXISTING STRUCTURE. ALL WORK TO BE PERFORMED PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**

  45. PermitAlterations

    Permit PP-2024-006516 · Completed

    Disconnect and remove existing non medical Natural Gas, Vacuum, Air, and Domestic Water. Install 1 new cabinet mounted sink and 1 faucet according to the 2018 PPC and per plans.

  46. PermitAddition and/or Alterations

    Permit FP-2024-000862 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (9) EXISITNG SPRINKLERS TO ACCOMODATE NEW CATH LAB CEILING LAYOUT

  47. PermitAddition and/or Alteration

    Permit CP-2024-001957 · Completed

    FOR LEVEL 2 ALTERATIONS TO EXISTING MEDICAL OFFICE AND LABATORY AS PER PLANS. NO CHANGE IN OCCUPANCY CLASSIFICATION.

  48. CertificationFire Alarm Certification

    Certification BC-2024-018668 · Certified

    Expires 2025-03-27

  49. PermitAddition and/or Alteration

    Permit EP-2024-001331 · Completed

    AMENDMENT: Fire alarm system modifications for the Jeanes Hospital emergency department expansion project including new speaker strobe lights and new detection. All work to conform to 2016 NFPA 72. Electrical Scope of expansion of Jeanes Hospital emergency department. New normal and emergency powered panelboards and transformers. Power connections to new AHU, AC unit, and exhaust fans. New lighting and lighting controls. New receptacles and branch wiring. Extension of existing nurse call system. Rough-in of tele/data and security device locations. All work to conform to 2017 NEC

  50. CertificationFire Alarm Certification

    Certification BC-2024-007799 · Certified

    Expires 2025-03-21

  51. CertificationFire Alarm Certification

    Certification BC-2024-010330 · Certified

    Expires 2025-03-21

  52. PermitAddition and/or Alteration

    Permit EP-2024-002028 · Completed

    Add new fire alarm devices, change out fire alarm devices, relocate existing fire alarm devices as per 2016 NFPA 72.

  53. PermitAddition and/or Alterations

    Permit FP-2024-000441 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (11) sprinkler heads as per NFPA 13

  54. PermitNew Construction or Additions

    Permit PP-2023-016574 · Completed

    INSTALL 13 LAVATORIES, 3 WATER CLOSETS, 1 SHOWER/TUB, 4 FLOOR DRAINS, 3 HOT WATER HEATERS AND 2 HOSE BIBBS ACCORDING TO THE 2018 PPC AND PER PLANS.

  55. PermitAlterations

    Permit PP-2023-016451 · Completed

    Plumbing permit for CP-2023-005729

  56. CertificationSpecial Hazards Certification

    Certification BC-2024-002415 · Certified

    Expires 2025-01-22

  57. PermitNew Construction

    Permit FP-2023-001350 · Completed

    FOR THE INSTALLATION OF 38 NEW PENDENT SPRINKLERS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.

  58. PermitAddition and/or Alterations

    Permit MP-2023-005281 · Issued

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.**

  59. PermitAddition and/or Alteration

    Permit EP-2023-011802 · Completed

    Install lighting, receptacles, HVAC power wiring, tele data stubs and install MDP panel as per single line as per 2017 NEC.

  60. PermitNew Construction

    Permit MP-2023-005100 · Completed

    FOR INSTALLATION OF NEW HVAC SYSTEM INCLUDING MECHANICAL APPLIANCES, REGISTERS AND DIFFUSERS WITH ASSOCIATED DUCTWORK AND ACCESSORIES AS PER PLANS.

  61. PermitAddition and/or Alteration

    Permit CP-2023-005729 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO COMPUTERIZED TOMOGRAPHY (CT) ROOM ON THE FIRST FLOOR LEVEL OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW*

  62. PermitAddition and/or Alteration

    Permit CP-2023-000897 · Completed

    FOR LEVEL II ALTERATIONS AND ADDITION (WITH NO CHANGE IN OCCUPANCY) PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED WITH NFPA 13. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.

  63. PermitAddition and/or Alterations

    Permit MP-2023-004930 · Completed

    FOR THE ALTERATIONS TO EXISTING HVAC SYSTEM INCLUDING NEW GRILLE, REGISTERS AND DIFFUSERS WITH ASSOCIATED DUCKWORK AND ACCESSORIES AS PER PLANS.

  64. PermitAlterations

    Permit PP-2023-015413 · Completed

    Install hand sink.

  65. CertificationFire Alarm Certification

    Certification BC-2023-023021 · Certified

    Expires 2024-11-08

  66. AppealZBA Permit Denial - Special Exception

    Appeal ZP-2023-004194 · Completed · Granted

    Related permit ZP-2023-004194 · [SPECIAL EXCEPTION] FOR THE ERECTION OF BUILDING ADDITION BELOW AN EXISTING STRUCTURE ACCESSORY TO EXISTING HOSPITAL COMPLEX ON THE SAME LOT WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION. SIZE AND LOCATION AS SHOW

  67. PermitAddition and/or Alteration

    Permit EP-2023-010339 · Completed

    Renovate the existing Cath Lab-1, includes new lighting, wiring devices, lighting controls, x-ray equipment power, empty conduit raceway for x-ray cable system. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **SEPARATE FIRE ALARM PERMIT REQ'D**

  68. PermitAddition and/or Alteration

    Permit CP-2023-005487 · Completed

    FOR LEVEL II ALTERATIONS (WITH NO CHANGE IN OCCUPANCY) PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.

  69. PermitNew construction, addition, GFA change

    Permit ZP-2023-004194 · Completed

    FOR AN ADDITION TO AN EXISTING BUILDING. SIZE AND LOCATION PER APPROVED PLANS.

  70. CertificationFacade Report

    Certification BC-2023-018032 · Safe

    Expires 2028-08-01

  71. CertificationSpecial Hazards Certification

    Certification BC-2023-014669 · Certified

    Expires 2024-07-07

  72. CertificationFire Alarm Certification

    Certification BC-2022-018870 · Certified

    Expires 2023-11-16

  73. CertificationFire Alarm Certification

    Certification BC-2022-016621 · Certified

    Expires 2023-11-08

  74. PermitAlterations

    Permit PP-2022-015430 · Expired

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  75. PermitAddition and/or Alteration

    Permit EP-2022-009568 · Completed

    Provide new fire alarm notification appliances, smoke detectors, duct smoke detectors, pull stations, relay modules, and local extender control panel. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  76. PermitAddition and/or Alteration

    Permit CP-2022-005274 · Expired

    FOR LEVEL II ALTERATIONS TO AN EXISTING BUILDING WITH INSTITUTIONAL (I-2, HOSPITAL) OCCUPANCY , ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ** ASBESTOS REMEDIATION IS REQUIRED **

  77. PermitAddition and/or Alteration

    Permit EP-2022-009333 · Completed

    Alteration to Jeanes Hospital emergency department to included new lighting and light switching, new hospital grade receptacles and branch wiring, modifications to existing panelboards, nurse call system devices, tele/data rough-in, and relocated access control system devices. Fire alarm system devices are existing to remain. All work to conform to the 2017 edition of the NEC.

  78. PermitAddition and/or Alterations

    Permit MP-2022-004497 · Completed

    FOR THE INSTALLATION OF ONE (1) VAV, GRDSs, AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC AND PA DOH APPROVAL DATED 12/15/2021. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2022-003492 FOR ASSOCIATED BUILDING ALTERATIONS PERMIT.

  79. PermitAlterations

    Permit PP-2022-012589 · Completed

    Install waste piping from fixtures. Install of water piping to fixtures. (3) Wall hung Lavatories

  80. PermitAddition and/or Alteration

    Permit CP-2022-003492 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO TRIAGE AREA ON THE FIRST FLOOR OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  81. CertificationSprinkler Certification

    Certification BC-2022-014523 · Certified

    Expires 2023-08-11

  82. CertificationSprinkler Certification

    Certification BC-2022-013229 · Deficient

  83. CertificationSprinkler Certification

    Certification BC-2022-014334 · Certified

    Expires 2023-07-20

  84. PermitAddition and/or Alteration

    Permit CP-2022-001488 · Expired

    FOR LEVEL II ALTERATIONS TO AN EXISTING SPACE WITHIN A HEALTH CARE FACILITY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR MEP AND ALL OTHER WORK.

  85. PermitAlterations

    Permit PP-2022-005986 · Completed

    Install waste piping from fixtures. Install water piping to fixtures. Furnish & install (1) Clinical sink, (3) Water closets, (7) Lavatories, (4) Sinks, (3) Floor drains, (1) Mop Receptor, (1) Eye wash station.

  86. PermitAddition and/or Alterations

    Permit MP-2022-002237 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK FOR A HEALTH FACILITY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTUERER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  87. PermitAddition and/or Alteration

    Permit EP-2021-011865 · Completed

    INSTALL (2) NEW PANELS AND FEEDERS. INSTALL LIGHTS NORMAL AND EMERGENCY, EXIT SIGNS, SWITCHES, LIGHTING CONTROLS, SENSORS AND RECEPTACLES. PROVIDE POWER FOR THE MECHANICAL AND HVAC EQUIPMENT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC IN PARTICULAR ARTICLE 517. ** NO FIRE ALARM WORK.

  88. PermitAddition and/or Alterations

    Permit FP-2022-000902 · Completed

    RELOCATE 55 EXISTING SPRINKLER HEADS FOR LEVEL 2 ALTERATIONS HEALTH FACILITY, AREA IS NOTED AS JEANES HOSPITAL OBSERVATION UNIT

  89. PermitRoof Covering Replacement

    Permit GM-2022-002628 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  90. CertificationFire Alarm Certification

    Certification BC-2022-005282 · Certified

    Expires 2023-03-29

  91. PermitAddition and/or Alteration

    Permit CP-2021-007204 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING HEALTH FACILITY TO THE SECOND FLOOR LEVEL OF AN EXISTING SPACE, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  92. PermitAddition and/or Alteration

    Permit EP-2020-007455 · Completed

    ELECTRICAL WORK TO SUPPORT THE RENOVATION OF PULMONARY CENTER AREA INCLUDING INTERIOR WIRING, RECEPTACLES, RELOCATED LIGHTING FIXTURES, NURSE CALL DEVICES AS PER 2017 NEC.

  93. PermitAlterations

    Permit PP-2020-008592 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  94. PermitAddition and/or Alteration

    Permit CP-2020-004393 · Completed

    LEVEL I INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) .ALTERATION TO INCLUDE MINOR DEMOLITION ,PROVIDE FINISHES UPGRADE AND FURNISHING FOR A SUITE(PULMONARY) LOCATED AT THE GROUND FLOOR OF AN EXISTING HOSPITAL.** ALL WORK TO BE PERFORMED AS PER APPROVED PLANS**EXISTING BUILDING IS FULLY SPRINKLERED **IEBC 2018** ANY WORK PERFORMED IN DEVIATION WITH THE APPROVED PLAN WILL REQUIRED AN AMENDED PERMIT **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**

  95. PermitNew Construction

    Permit 1040825 · Issued

    REPLACEMENT OF 125KW EMERGENCY DIESEL GENERATOR ON OUTDOOR PAD PER 2017 NEC (EAST DIST)

  96. License terminal eventJEANES HOSPITAL: Annual Small Games Of Chance business license marked inactive

    License 520053 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  97. PermitElectrical

    Permit 1005259 · COMPLETED

    20 NEW FIXTURES, 23 WIRING DEVICES, 4 NURSE CALL STATIONS, 4 ALARM DEVICES, 2 RELOCATED AND 2 NEW AS PER NFPA 72 AND 2008 NEC (CC DIST)

  98. PermitMechanical

    Permit 1002442 · COMPLETED

    HVAC ALTERATIONS TO INCLUDE INSTALLATION OF CEILING MOUNTED FAN COIL UNIT (FCU) & ASSOCIATED TERMINAL DEVICES PER APPROVED PLANS TO SERVE PREVIOUSLY APPROVED TREATMENT ROOMS.

  99. PermitPlumbing

    Permit 1002807 · COMPLETED

    INSTALL WASTE PIPING FROM FIXTURES INSTALL WATER PIPING TO FIXTURES INSTALL 2 FIXTURES AS PER 2004 PPC

  100. PermitAddition and/or Alteration

    Permit 997006 · Expired

    FOR LEVEL II ALTERATIONS TO AN EXISTING HOSPITAL TO INLCUDE NEW PARTITIONS, FIXTURES, FURNISHINGS, AND FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL MEP AND FIRE SUPPRESSION WORK.

  101. PermitNew Construction

    Permit 975677 · Issued

    PROVIDE 50AMP 460V 3 PAHSE FEED TO MAIN EQUIPMENT BREAKER(FURNISHED BY OWNER) TWO DUPLEX RECEPS ON EXISTING CIRCUIT WIRE THROUGH SYSTEN WIREMOLD PER 2017 NEC

  102. PermitSuppression

    Permit 843691 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2007, STANDARD 13 WITH TIE-IN TO THE EXISTING SYSTEM AT JEANES HOSPITAL.ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.* ASBESTOS REMEDIATION REQUIRED PRIOR TO START OF WORK

  103. InvestigationCI INSP

    Case 579675 · PASSED

    The cited inspection visit was marked passed.

  104. InvestigationCI INSP

    Case 579675 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  105. ViolationCERTIFICATION

    Case 579675 · Violation 4376120 · Code FC-13-915 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  106. InvestigationCI INSP

    Case 579675 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  107. PermitPlumbing

    Permit 749764 · COMPLETED

    INSTALLATION OF 3- NEW SINKS

  108. PermitSuppression

    Permit 749140 · COMPLETED

    RELOCATE (23) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  109. PermitSuppression

    Permit 727079 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2007, STANDARD 13 WITH 2-INCH DIAMETER TIE-IN TO EXISTING SYSTEM AT JEANES HOSPITAL.

  110. PermitElectrical

    Permit 727198 · COMPLETED

    ELECTRIC SERV REPLACEMENT AT 13.2KV & 4.16KV LEVELS, NEW INCOMING SERV CABLES & DUCT BANK,ELECTRICAL SUBSTATION, PAD MOUNTED TRANSFORMER, CAPACITORS, ASSOCIATED ELECTRICAL EQUIPMENT AS PER NEC 2008 & FIRE ALARM DEVICES AS PER NFPA 72

  111. PermitElectrical

    Permit 725992 · COMPLETED

    CONVERT EXISTING STORAGE SPACE INTO CATH LAB POWER SYSTEMS, LIGHTING AS PER 2008 NEC (EAST DISTRICT)

  112. PermitElectrical

    Permit 728621 · COMPLETED

    LEVEL II ALTERATIONS. TO INCLUDE THE REMOVAL OF AN EXISTING TRAILER HOUSING AN MRI AND REPLACING WITH A NEW MRI TRAILER FOR AN EXISTING HOSPITAL. NEW ELECTRICAL FEEDER FROM EXISTING PANEL SINCE TRAILER IS ARRIVING PRE-WIRED AS PER 2008 NEC (EAST DISTRICT) INSTALLATION OF A NEW COMPLETE FIRE ALARM SYSTEM AS PER NFPA72

  113. PermitMechanical

    Permit 727338 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM FOR MRI CASSETTE TO INCLUDE REMOVAL AND DISCONNECT OF EXISTING PACKAGE CHILLER AND INSTALLATION OF NEW 10 TON UNIT AS PER APPROVED PLANS AND PA DOH APPROVAL. WORK TO INCLUDE DISCONNECTION AND RECONNECTION OF EXISTING MEDICAL GAS LINES AND SPLIT SYSTEM AIR CONDITIONER.

  114. PermitPlumbing

    Permit 728499 · COMPLETED

    REPLACE 1-HAND WASH SINK. THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  115. PermitAddition

    Permit 721433 · COMPLETED

    ERECTION OF A TWO STORY ADDITION TO AN EXISTING MECHANICAL EQUIPMENT BUILDING ON A HOSPITAL COMPLEX AS PER APPROVED PLANS. BUILDING NOT REQUIRED TO BE SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  116. PermitMajor alteration

    Permit 715492 · COMPLETED

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) TO INCLUDE THE REMOVAL OF AN EXISTING TRAILER (CASSETTE) HOUSING AN MRI, AND THE REPLACEMENT WITH A NEW MRI TRAILER (CASSETTE) FOR AN EXISTING HOSPITAL AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  117. PermitMajor alteration

    Permit 716785 · COMPLETED

    INTERIOR ALTERATIONS OF THE 1ST AND 2ND FLOOR CATH LAB IN AN EXISTING HOSPITAL; NO CHANGE IN USE/OCCUPANCY. ALTERATIONS TO INCLUDE DEMOLITION AND ERECTION OF NONBEARING PARTITIONS, NEW FINISHES, AND MILLWORK AND STRUCTURAL ALTERATIONS TO FRAMING. ALL WORK PER DOH APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR CHANGES TO MECHANICAL, PLUMBING, ELECTRICAL AND FIRE SUPPRESSION.

  118. PermitMechanical

    Permit 722659 · COMPLETED

    FOR THE ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMMODATE INTERIOR ALTERATIONS (SEE A/P NO 716785).

  119. PermitZoning/use

    Permit 615132 · COMPLETED

    FOR THE ERECTION OF AN ADDITION TO EXISTING DETACHED ACCESSORY MECHANICAL EQUIPMENT BUILDING & FOR REMOVAL OF EXISTING HERITAGE TREE; SIZE & LOCATION AS SHOWN IN APPROVED PLANS. FOR USE AS MECHANICAL EQUIPMENT ACCESSORY TO EXISTING HOSPITAL COMPLEX W. OTHER USES AS PREVIOUSLY APPROVED

  120. AppealZoning board appeal

    Appeal 25704 · CLOSED · Granted

    Related permit 615132 · FOR THE ERCTION OF AN ADDITION TO EXISTING DETACHED ACCESSORY MECHANICAL EQUIPMENT BUILDING & FOR REMOVAL OF EXISTING HERITAGE TREE; SIZE & LOCATION AS SHOWN IN APPROVED PLANS. FOR USE AS MECHANICAL EQUIPMENT ACCESSORY TO EXISTING HOSPITAL

  121. PermitPlumbing

    Permit 616806 · COMPLETED

    ADDING 7N SINKS, 2 WATER CLOSETS, 2 EYE WASH BRANCHING OFF OF HALLWAY MAINS - THE INSTALLATION WILL COMPY WITH THE PHILADEPHIA PLUBMING CODE 2004

  122. PermitSuppression

    Permit 628826 · COMPLETED

    RELOCATE (37) EXISTING SPRINKLER HEADS.

  123. PermitMajor alteration

    Permit 613211 · COMPLETED

    INTERIOR /EXTERIOR ALTERATIONS, INTERIOR DEMO FOR FIT OUT AND RENOVATIONS & FINISHES FOR RELOCATION OF BONE MARROW TRANSPLANT CLINIC 5TH FLOOR 5A SPACE OF EXISITNG HOSPITAL. PENTHOUSE / LOWER ROOF ALTERATIONS NEW STEEL DUNNAGE FRAMING FOR ROOF AHU SUPPORT. NO CHANGE IN USE /OCCUPANCY. ADDITIONAL PERMITS REQ :ELECTRICAL, PLUMBING, HVAC, SPRINKLERS.

  124. PermitElectrical

    Permit 615414 · COMPLETED

    PARTIAL RENOVATION OF FIFTH FLOOR & ADDITION OF NEW ROOF TOP AC UNIT AS PER NEC 2008 EAST DISTRICT

  125. PermitMechanical

    Permit 616807 · COMPLETED

    ALTERATIONS TO HVAC SYSTEM ON FIFTH FLOOR OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS.

  126. PermitPlumbing

    Permit 577737 · COMPLETED

    INSTALL 1 FLOOR DRAIN AND PIPING IN BOILER HOUSE LOWER LEVEL MECHANICAL ROOM APPROX 10' OF 6" CAST IRON PIPE BELOW GRADE WITH M6 FITTINGS AND TIE INTO EXISTING 8' CAST IRON PIPE, "THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004" - HOSPITAL

  127. PermitPlumbing

    Permit 575020 · COMPLETED

    INSTALL 2 NEW SINKS TO EXISTING ROUGHIN,INSTALL 2 SINKS TO NEW ROUGHIN,INSTALL 1 WATER CLOSET TO NEW ROUGHIN AND INSTALL ONE LAV TO NEW ROUGHIN (HEALTH CARE FACILITY)

  128. PermitMajor alteration

    Permit 571427 · COMPLETED

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) TO AN EXISTING MEDICAL OFFICE TO CREATE AN ACCESSIBLE TOILET ROOM AND NEW BREAK ROOM AS PER APPROVED PLANS. **SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**

  129. PermitElectrical

    Permit 544144 · COMPLETED

    ADD 4-TRACK LIGHTS, 3-DOWN LIGHTS, 3-SWITCHES, 11-RECEPTACLES & 4-TELE/DATA OUTLETS (MEDICAL OFFICE) EAST DISTRICT

  130. PermitMajor alteration

    Permit 540019 · COMPLETED

    LEVEL II ALTERATION FOR OPTHAMOLOGY OPTICAL EXPANSION AS PER PLANS

  131. PermitAlteration

    Permit 532453 · EXPIRED

    REMOVE THE EXISTING SHINGLES DOWN TO EXISTING WOOD OR NAILABLE CONCRETE DECK. FURNISH AND INSTALL NEW GAF SLATE LINE SHINGLES WITH GAF WEATHER WATCH ANDICE AND SNOW.

  132. License terminal eventJEANES HOSPITAL: Dumpster License - Private Property L&I license filing marked inactive

    License 522535 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  133. InvestigationCI INSP

    Case 381196 · PASSED

    The cited inspection visit was marked passed.

  134. ViolationVIOL C&I MESSAGE

    Case 381196 · Violation 2796902 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  135. ViolationFA-REPAIR SYSTEM

    Case 381196 · Violation 2796903 · Code FC-901.6/6 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  136. ViolationANNUAL CERT FIRE ALARM

    Case 381196 · Violation 2796905 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  137. ViolationFIRE-PULL STATION SIGNS

    Case 381196 · Violation 2796904 · Code FC-907.4/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  138. InvestigationCI INSP

    Case 381196 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  139. PermitElectrical

    Permit 439529 · COMPLETED

    FIRE ALARM - REPLACE EXISTING DEVICES ELECTRICAL - REMODEL GIFT SHOP PER DRAWINGS - ALL PER NFPA 72 AND 2008 NEC

  140. PermitSuppression

    Permit 442369 · COMPLETED

    RELOCATE (7) EXISTING SPRIKLER HEADS IN HOSPITAL GIFT SHOP.

  141. PermitAlteration

    Permit 441439 · COMPLETED

    ROOF REPLACEMENT (SINGLE PLY./FULLY ADHERED).

  142. PermitMajor alteration

    Permit 434772 · REVOKED

    INSTALL 3 ANTENNAS, 6 RRH UNITS, 3 CABLES, 3 NEW CABINETS. REMOVE 3 ANTENNAS, 6 COAX, 2 CABINETS

  143. PermitPlumbing

    Permit 435533 · COMPLETED

    INSTALL 1 KS TO EXISTING H/C VENT AND SANITARY PIPING(HOSPITAL)

  144. PermitZoning/use

    Permit 426944 · COMPLETED

    ERECT 3 ANTENNA, 6 RRH'S, 3 EQUIPMENT CABINETS, 3 ANTENNAS AND 2 CABINETS

  145. PermitMechanical

    Permit 430162 · COMPLETED

    HVAC MODIFICATIONS, PART OF GIFT SHOP RENOVATIONS.

  146. PermitMajor alteration

    Permit 429386 · COMPLETED

    INTERIOR RENOVATION OF EXISTING GIFT SHOP LOCATED WITHIN JEANES HOSPITAL.

  147. PermitOperations

    Permit 21525 · COMPLETED

    05/17/2012 ERECT ONE (1) ASSEMBLY USE TENT FOR JEANES HOSPITAL

  148. PermitMechanical

    Permit 373616 · COMPLETED

    INSTALLATION OF DUCTWORK, MECHANICALS AND RELATED PIPING

  149. PermitElectrical

    Permit 374745 · COMPLETED

    GENERAL LIGHTING, EMERG & EXIT LIGHTING, SWITCHES, RECEPS, 2 PANELBOARDS WITH FEEDERS, NURSE CALL AS PER 2008 NEC (EAST DISTRICT) FIRE ALARM EXTENDED FROM EXISTING SYSTEM, NEW FIRE ALARM SMOKES, BELLS, STROBES, BOOSTER PANEL, PULL STATIONS AS PER NFPA 72. EXCLUDES SECURITY ALARM, PHONE, DATA, SOUND, PAGING AND LOW VOLT WIRING IN ITS ENTIRETY.(HOSPITAL)SEE LOG NOTES

  150. ViolationPERMB- WK DONE W/O NOTIFY INSP

    Case 373602 · Violation 2289518 · Code A-302.11/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  151. PermitSuppression

    Permit 377536 · COMPLETED

    RELOCATE (45) SPRINKLER HEADS TO ACCOMMODATE NEW WALL AND CEILING LAYOUT.

  152. ViolationPERMB- WK DONE W/O NOTIFY INSP

    Case 372400 · Violation 2289516 · Code A-302.11/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  153. ViolationPERMB- WK DONE W/O NOTIFY INSP

    Case 372405 · Violation 2289520 · Code A-302.11/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  154. PermitPlumbing

    Permit 373602 · COMPLETED

    RENOVATION OF EXISTING PLUMBING MEDICAL GAS, INSTALL NEW SANITARY HOT AND COLD WATER AND MEDICAL GAS INCLUDING NEW ZONE VALVE OUTLETS, SET PLUMBING FIXTURES, HOSPITAL

  155. PermitMajor alteration

    Permit 372400 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLANS-HOSPITAL

  156. PermitDemolition

    Permit 372405 · COMPLETED

    INT DEMO OF NON BEARING PARTITIONS ONLY, FIRST FLOOR. (WOUND CARE CENTER)

  157. PermitOperations

    Permit 21150 · COMPLETED

    09/26/2011 ERECT (2) ASSEMBLY USE TENTS

  158. PermitPlumbing

    Permit 343913 · COMPLETED

    REPLACE APPROXIMATELY 100'-0" OF 8" HOUSE DRAIN PIPING UNDER THE PAVED AREA BEHIND THE KITCHEN - EXCAVATE AND BACKFILL AS REQUIRED

  159. PermitElectrical

    Permit 338376 · COMPLETED

    PROVIDE LIGHTING RECEPTACLES SWITCHES FIRE ALARM DEVICES AND EQUIPMENT POWER WIRING. EXCLUDES TELE/DATA AND SECURITY WIRING IN ITS ENTIRETY AS PER 2008 NEC

  160. PermitSuppression

    Permit 343298 · COMPLETED

    RELOCATE 20 EXISTING SPRINKLER HEADS TO ACCOMMODATE NEW CEILING LAYOUT - 2ND FLOOR - FOUNDERS HALL

  161. PermitMechanical

    Permit 341753 · COMPLETED

    INSTALLATION OF DUCTWORK AND MECHANICAL UNITS

  162. PermitMajor alteration

    Permit 332598 · COMPLETED

    INTERIOR ALTERATIONS PER PLAN, 3RD FLOOR HUMAN RESOURCES OFFICES

  163. PermitElectrical

    Permit 327535 · COMPLETED

    INSTALLATION OF SECURITY CAMERAS AND EQUIPMENT, FOX CHASE TANK, AKA LAND LEASED FROM JEANES HOSPITAL

  164. InvestigationCI INSP

    Case 241943 · PASSED

    The cited inspection visit was marked passed.

  165. License issue eventJEANES HOSPITAL: Dumpster License - Private Property L&I license filing initially issued

    License 522535 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  166. InvestigationCI INSP

    Case 241943 · PASSED

    The cited inspection visit was marked passed.

  167. License issue eventJEANES HOSPITAL: Annual Small Games Of Chance business license initially issued

    License 520053 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  168. License issue eventJEANES HOSPITAL: Monthly Small Games of Chance business license initially issued

    License 520055 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  169. PermitPlumbing

    Permit 311872 · COMPLETED

    RE-REOUGH OF 3 SINKS EXTENDING 2 FEET AND INSTALLATION OF SINKS

  170. InvestigationCI INSP

    Case 241943 · PASSED

    The cited inspection visit was marked passed.

  171. PermitSuppression

    Permit 303805 · COMPLETED

    FOR THE INSTALLATION OF A SPRINKLER SYSTEM AND CONNECTION TO EXISTING STANDPIPE FOR HOSPITAL.

  172. PermitMajor alteration

    Permit 308061 · COMPLETED

    INTERIOR DEMOLITION/RENOVTIONS AS PER PLANS FOR HOSPITAL.

  173. InvestigationBP_BLDG

    Case 251201 · PASSED

    The cited inspection visit was marked passed.

  174. PermitSuppression

    Permit 301086 · COMPLETED

    INSTALL 80 SPRINKLERS ON THE 1ST FL OF THE BLDG IN THE CARDIOLOGY SUITE FOR FR LAMARRA CONSTRUCTION

  175. PermitMajor alteration

    Permit 306311 · COMPLETED

    INTERIOR ALTERATIONS TO CARDIAC REHAB, AS PER PLANS

  176. InvestigationCI INSP

    Case 241943 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  177. PermitMajor alteration

    Permit 286866 · COMPLETED

    ALTERATIONS AS PER PLANS

  178. PermitAdministrative

    Permit 300953 · COMPLETED

    AMEND BLDG. PERMIT #284017 TO REVISE FLOOR LAYOUT.

  179. PermitAdministrative

    Permit 301721 · COMPLETED

    30 DAY TCO FOR 1ST FLOOR PHYSICIAN OFFICES.

  180. PermitOperations

    Permit 20672 · COMPLETED

    8/30/10-ERECTION OF (1)-ASSEMBLY USE TENT

  181. ViolationPERMB- EXTEND FIRE SUPP SYS

    Case 251201 · Violation 1816753 · Code A-301.1/28 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  182. InvestigationBP_BLDG

    Case 251201 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  183. PermitOperations

    Permit 20636 · COMPLETED

    8/30/10-ERECTION OF (2)-ASSEMBLY USE TENTS

  184. PermitMechanical

    Permit 288964 · COMPLETED

    FURNISH & INSTALL ALL DUCTWORK, GRD'S AS PER PLANS IN CONJUNCTION WITH ALTERATIONS PERMITS AP284017,286863,286866

  185. PermitMajor alteration

    Permit 284017 · COMPLETED

    INTERIOR ALTERATIONS TO THE 1ST FLOOR OF THE AMBULATORY CARE BLDG FOR USE AS PHYSICIAN OFFICES AS PER PLANS

  186. PermitElectrical

    Permit 290227 · COMPLETED

    INSTALL 2 LIGHT FIXTURES, 1 SWITCH, 1 GFCI RECEPTACLE & 1 EXHAUST FAN.

  187. PermitElectrical

    Permit 290228 · COMPLETED

    INSTALL 12 LIGHT FIXTURES, 1 SWITCH & 1 RECEPTACLE.

  188. PermitPlumbing

    Permit 288954 · COMPLETED

    INSTALLATION OF PATIENT BATHROOMS AND EXAM SINKS, DHW,DEC,JW,SV

  189. PermitSuppression

    Permit 289862 · COMPLETED

    RELOCATE (2) SPRINKLERS IN ER

  190. PermitSuppression

    Permit 289864 · COMPLETED

    RELOCATE 6 SPRINKLERS.

  191. PermitPlumbing

    Permit 288955 · COMPLETED

    INSTALLATION OF 3 PIECE BATHROOM, DHW,DEC,SW,SV

  192. ViolationANNUAL CERT FIRE ALARM

    Case 241943 · Violation 1930676 · Code FC-914.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  193. InvestigationCI INSP

    Case 241943 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  194. PermitMajor alteration

    Permit 286863 · COMPLETED

    INTERIOR RENOVATIONS AT 2ND FL.

  195. PermitDemolition

    Permit 280704 · COMPLETED

    INTERIOR NON-BEARING DEMOLITION ON GROUND LEVEL - AMBULATORY CENTER

  196. PermitOperations

    Permit 20340 · COMPLETED

    5/14/10-ERECTION OF (1)-40X80 ASSEMBLY USE TENT

  197. PermitSuppression

    Permit 240698 · EXPIRED

    ADD NEW HEADS IN RENNOVATED PHARMACY AS PER PLANS

  198. PermitMajor alteration

    Permit 236654 · COMPLETED

    INTERIOR RENNOVATIONS TO PHARMACY AREA AS PER PLANS

  199. PermitElectrical

    Permit 229459 · COMPLETED

    INSTALL LIGHTING, RECEPTACLES, SWITCHES, EMERGENCY LIGHTING & BRANCH CIRCUITS PER PLAN.

  200. PermitElectrical

    Permit 213552 · COMPLETED

    1ST FL STAPLEY, PROVIDE GENERAL LIGHTING FIXTURES, EMERGENCY & EXIT LIGHTING, RECPTS, SWITCHES, AND BRANCH CIRCUIT WIRING, EXISTING PANELS USED FOR NEW BRANCH CIRCUITS. EXCLUDES FIRE ALARM, SECURITY, PHONE, DATA, SOUND, PAGING, AND LOW VOLTAGE WIRING.

  201. InvestigationCI INSP

    Case 163267 · PASSED

    The cited inspection visit was marked passed.

  202. PermitElectrical

    Permit 192260 · COMPLETED

    ADD DEVICES TO EXISTING SYSTEM NO NEW FIRE ALARM PANEL AS PER NFPA72 (EAST DISTRICT)

  203. PermitMechanical

    Permit 178914 · COMPLETED

    CATH LAB HVAC UPGRADE

  204. PermitElectrical

    Permit 180877 · COMPLETED

    INSTALL ATS, NORMAL AND EMERGENCY PANELS FOR NEW CATHLAB. INSTALL NORMAL AND EMERGENCY BRANCH WIRING, NEW LIGHTING AND NURSE CALL IN PREPORATORY UNIT. PULL SIEMEN'S SYSTEMS WIRING. WILL APPLY FOR A SEPARATE FIRE ALARM PERMIT.(EAST DIST)

  205. PermitPlumbing

    Permit 181410 · EXPIRED

    FIXTURE REPLACEMENT

  206. PermitSuppression

    Permit 176675 · COMPLETED

    TIE INTO 4" RISER WITH STAIR AND INSTALL SPRINKLER PROTECTION THROUGHOUT AREA SHOWN

  207. PermitMajor alteration

    Permit 176418 · COMPLETED

    INTERIOR ALTERATIONS PER PLAN - 2ND FLOOR CATH. LAB.

  208. PermitFast form building

    Permit 176854 · COMPLETED

  209. PermitElectrical

    Permit 173798 · COMPLETED

    MISCELLANEOUS DISCONNECTION OF EQUIPMENT IN PREPARATION FOR FUTURE CONSTRUCTION. WILL APPLY FOR A SEPARATE PERMIT WHEN DRAWINGS ARE ISSUED AS PER 2005 NEC (EAST DIST)

  210. PermitDemolition

    Permit 173814 · COMPLETED

    DEMOLITION OF NON LOAD BEARING WALLS

  211. PermitMajor alteration

    Permit 171511 · COMPLETED

    INTERIOR RENOVATIONS.

  212. PermitMajor alteration

    Permit 171508 · COMPLETED

    INTERIOR RENOVATIONS AS PER PLANS

  213. PermitPlumbing

    Permit 172237 · COMPLETED

    FIXTURE REPLACEMENT

  214. PermitElectrical

    Permit 162487 · COMPLETED

    NEW 4 STORY PARKING GARAGE POWER, LIGHTING, ETC.

  215. PermitDemolition

    Permit 168668 · COMPLETED

    INTERIOR NON-BEARING DEMOLITION (FOUNDERS BLDG., 2ND FLOOR)

  216. PermitAdministrative

    Permit 165541 · COMPLETED

    AMEND A/P-156861 TO SHOW CORRECT ADDRESS AND REMOVE SPRINKLERS FROM PLAN

  217. PermitElectrical

    Permit 157567 · COMPLETED

    PROVIDE 12 DUPLEX RECEPTS WIRED INTO EXISTING CIRCUITS, 6 SINGLE POLE SWITCHES, 1 COPY MACHINE RECEPT, 2 VIEW BOX RECEPTS, 1 COUNTER GFI, RELOCATE 4 CEILING LIGHT FIXTURES, F & I 2 NEW EXIT LIGHT FIXTURES, AS PER 2005 NEC (NORTH DIST) EXCLUDING, TEL, FIRE ALARM, SECURITY AND DATA WIRING IN ITS ENTIRETY, NO PATIENT CARE

  218. ViolationVIOL C&I MESSAGE

    Case 163267 · Violation 970872 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  219. ViolationANNUAL CERT FIRE SUPP

    Case 163267 · Violation 970873 · Code FC-914.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  220. InvestigationCI INSP

    Case 163267 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  221. PermitOperations

    Permit 6918 · COMPLETED

    5/15/08 - TENT ERECTED ON HOSPTIAL SITE

  222. PermitNew construction

    Permit 116109 · COMPLETED

    CONSTRUCT 4 LEVEL PARKING GARAGE

  223. PermitElectrical

    Permit 132528 · COMPLETED

    INSTALL 1 TV RECEPTACLE, 1 3-WAY SWITCH, 2 EXIT LIGHTS, 1 EMERGENCY LIGHT, RELOCATE 1 HORN/STROBE, 1 SMOKE DETECTOR & 4 LIGHT FIXTURES.

  224. PermitFast form building

    Permit 131831 · COMPLETED

  225. PermitMajor alteration

    Permit 125438 · COMPLETED

    INTERIOR RENOVATIONS TO FOUNDER'S HALL, 3RD FLR.GASTROINTESTINAL WAITING AREA

  226. PermitElectrical

    Permit 107182 · COMPLETED

    FURNISH AND INSTALL 1 LIGHT SWITCH & 3 RECEPTS. RELOCATE EXISTING LIGHTING, REUSE CIRCUITS WHICH WERE POWERING THE OLD LIGHTING AND RECEPTS, PROVIDE NEW COVER PLATES ON EXISTING DEVICES. NO CHANGE IN LOAD AS PER 2005 NEC (EAST DIST)

  227. PermitOperations

    Permit 1518 · COMPLETED

    10/04/07 - TENTS ERECTED JEANES HOSPITAL - PARKING LOT AREA

  228. PermitMajor alteration

    Permit 104621 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLAN

  229. PermitZoning

    Permit 101872 · COMPLETED

    RELOCATE LOT LINES TO CREAT 2 LOTS FROM 2 LOTS; CONSTRUCT PRIVATE PARKING GARAGE HAVING 605 PARKING SPACES ON 7500 CENTRAL WITH CONNECTOR BUILDING TO 7701 BURHOLME FOR USE BY THE HOSPITAL EMPLOYEES;

  230. PermitZoning/use

    Permit 101874 · COMPLETED

    RELOCATE LOT LINES TO CREAT 2 LOTS FROM 2 LOTS; CONSTRUCT PRIVATE PARKING GARAGE HAVING 605 PARKING SPACES ON 7500 CENTRAL WITH CONNECTOR BUILDING TO 7701 BURHOLME FOR USE BY THE HOSPITAL EMPLOYEES;

  231. PermitElectrical

    Permit 67035 · COMPLETED

    INSTALL SEVEN (7) 115 VOLT OUTLETS ON WALL USING EXISTING CIRCUIT OF OPPOSITE WALL. WIRE SYSTEM M/C HEALTHCARE. APPROXIMATELY 20' EACH. (EAST DIST)

  232. PermitSign

    Permit 40386 · COMPLETED

    ERECT A DIRECTIONAL SIGN 2'6" X 6' AND HEIGHT FROM GRADE 2'6". 36" DEEP AND 24" WIDE.

  233. License issue eventJEANES HOSPITAL: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 347052 · Active

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 10:00 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)